1
|
Meyer T, Anders M, Pietzcker AZ, Doyley M, Görner S, Böhm O, Engl P, Safraou Y, Braun J, Sack I, Tzschätzsch H. Rapid wideband characterization of viscoelastic material properties by Bessel function-based time harmonic ultrasound elastography (B-THE). J Mech Behav Biomed Mater 2024; 160:106746. [PMID: 39303417 DOI: 10.1016/j.jmbbm.2024.106746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 09/10/2024] [Accepted: 09/14/2024] [Indexed: 09/22/2024]
Abstract
Elastography is an emerging diagnostic technique that uses conventional imaging modalities such as sonography or magnetic resonance imaging to quantify tissue stiffness. However, different elastography methods provide different stiffness values, which require calibration using well-characterized phantoms or tissue samples. A comprehensive, fast, and cost-effective elastography technique for phantoms or tissue samples is still lacking. Therefore, we propose ultrasound Bessel-fit-based time harmonic elastography (B-THE) as a novel tool to provide rapid feedback on stiffness-related shear wave speed (SWS) and viscosity-related wave penetration rate (PR) over a wide range of harmonic vibration frequencies. The method relies on external induction and B-mode capture of cylindrical shear waves that satisfy the Bessel wave equation for efficient fit-based parameter recovery. B-THE was demonstrated in polyacrylamide phantoms in the frequency range of 20-200 Hz and was cross-validated by magnetic resonance elastography (MRE) using clinical 3-T MRI and compact 0.5-T tabletop MRI scanners. Frequency-independent material parameters were derived from rheological models and validated by numerical simulations. B-THE quantified frequency-resolved SWS and PR 13 to 176 times faster than more expensive clinical MRE and tabletop MRE and have a good accuracy (relative deviation to reference: 6 %, 10 % and 4 % respectively). Simulations of liver-mimicking material phantoms showed that a simultaneous fit of SWS and PR based on the fractional Maxwell rheological model outperformed a fit on PR solely. B-THE provides a comprehensive and fast elastography technique for the quantitative characterization of the viscoelastic behavior of soft tissue mimicking materials.
Collapse
Affiliation(s)
- Tom Meyer
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Matthias Anders
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Anton Z Pietzcker
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Marvin Doyley
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY, USA
| | - Steffen Görner
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Oliver Böhm
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Pascal Engl
- Department of Physics, Sensor and Ultrasound Technology, University of Applied Sciences Merseburg, Merseburg, Germany
| | - Yasmine Safraou
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jürgen Braun
- Institute of Medical Informatics, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Ingolf Sack
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Heiko Tzschätzsch
- Institute of Medical Informatics, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
| |
Collapse
|
2
|
Gracioso Martins AM, Biehl A, Sze D, Freytes DO. Bioreactors for Vocal Fold Tissue Engineering. TISSUE ENGINEERING. PART B, REVIEWS 2022; 28:182-205. [PMID: 33446061 PMCID: PMC8892964 DOI: 10.1089/ten.teb.2020.0285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 01/14/2021] [Indexed: 02/03/2023]
Abstract
It is estimated that almost one-third of the United States population will be affected by a vocal fold (VF) disorder during their lifespan. Promising therapies to treat VF injury and scarring are mostly centered on VF tissue engineering strategies such as the injection of engineered biomaterials and cell therapy. VF tissue engineering, however, is a challenging field as the biomechanical properties, structure, and composition of the VF tissue change upon exposure to mechanical stimulation. As a result, the development of long-term VF treatment strategies relies on the characterization of engineered tissues under a controlled mechanical environment. In this review, we highlight the importance of bioreactors as a powerful tool for VF tissue engineering with a focus on the current state of the art of bioreactors designed to mimic phonation in vitro. We discuss the influence of the phonatory environment on the development, function, injury, and healing of the VF tissue and its importance for the development of efficient therapeutic strategies. A concise and comprehensive overview of bioreactor designs, principles, operating parameters, and scalability are presented. An in-depth analysis of VF bioreactor data to date reveals that mechanical stimulation significantly influences cell viability and the expression of proinflammatory and profibrotic genes in vitro. Although the precision and accuracy of bioreactors contribute to generating reliable results, diverse gene expression profiles across the literature suggest that future efforts should focus on the standardization of bioreactor parameters to enable direct comparisons between studies. Impact statement We present a comprehensive review of bioreactors for vocal fold (VF) tissue engineering with a focus on the influence of the phonatory environment on the development, function, injury, and healing of the VFs and the importance of mimicking phonation on engineered VF tissues in vitro. Furthermore, we put forward a strong argument for the continued development of bioreactors in this area with an emphasis on the standardization of bioreactor designs, principles, operating parameters, and oscillatory regimes to enable comparisons between studies.
Collapse
Affiliation(s)
- Ana M. Gracioso Martins
- Joint Department of Biomedical Engineering, College of Engineering, North Carolina State University/University of North Carolina-Chapel Hill, Raleigh, North Carolina, USA
- Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina, USA
| | - Andreea Biehl
- Joint Department of Biomedical Engineering, College of Engineering, North Carolina State University/University of North Carolina-Chapel Hill, Raleigh, North Carolina, USA
- Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina, USA
| | - Daphne Sze
- Joint Department of Biomedical Engineering, College of Engineering, North Carolina State University/University of North Carolina-Chapel Hill, Raleigh, North Carolina, USA
- Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina, USA
| | - Donald O. Freytes
- Joint Department of Biomedical Engineering, College of Engineering, North Carolina State University/University of North Carolina-Chapel Hill, Raleigh, North Carolina, USA
- Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
3
|
Li L, Stiadle JM, Lau HK, Zerdoum AB, Jia X, Thibeault SL, Kiick KL. Tissue engineering-based therapeutic strategies for vocal fold repair and regeneration. Biomaterials 2016; 108:91-110. [PMID: 27619243 PMCID: PMC5035639 DOI: 10.1016/j.biomaterials.2016.08.054] [Citation(s) in RCA: 68] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2016] [Revised: 08/29/2016] [Accepted: 08/31/2016] [Indexed: 01/01/2023]
Abstract
Vocal folds are soft laryngeal connective tissues with distinct layered structures and complex multicomponent matrix compositions that endow phonatory and respiratory functions. This delicate tissue is easily damaged by various environmental factors and pathological conditions, altering vocal biomechanics and causing debilitating vocal disorders that detrimentally affect the daily lives of suffering individuals. Modern techniques and advanced knowledge of regenerative medicine have led to a deeper understanding of the microstructure, microphysiology, and micropathophysiology of vocal fold tissues. State-of-the-art materials ranging from extracecullar-matrix (ECM)-derived biomaterials to synthetic polymer scaffolds have been proposed for the prevention and treatment of voice disorders including vocal fold scarring and fibrosis. This review intends to provide a thorough overview of current achievements in the field of vocal fold tissue engineering, including the fabrication of injectable biomaterials to mimic in vitro cell microenvironments, novel designs of bioreactors that capture in vivo tissue biomechanics, and establishment of various animal models to characterize the in vivo biocompatibility of these materials. The combination of polymeric scaffolds, cell transplantation, biomechanical stimulation, and delivery of antifibrotic growth factors will lead to successful restoration of functional vocal folds and improved vocal recovery in animal models, facilitating the application of these materials and related methodologies in clinical practice.
Collapse
Affiliation(s)
- Linqing Li
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Jeanna M Stiadle
- Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, University of Wisconsin-Madison, Madison, WI 53792, USA; Department of Communication Sciences and Disorders, University of Wisconsin-Madison, Madison, WI 53792, USA
| | - Hang K Lau
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA
| | - Aidan B Zerdoum
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA
| | - Xinqiao Jia
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA; Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA; Delaware Biotechnology Institute, 15 Innovation Way, Newark, DE 19711, USA
| | - Susan L Thibeault
- Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, University of Wisconsin-Madison, Madison, WI 53792, USA; Department of Communication Sciences and Disorders, University of Wisconsin-Madison, Madison, WI 53792, USA.
| | - Kristi L Kiick
- Department of Materials Science and Engineering, University of Delaware, Newark, DE 19716, USA; Department of Biomedical Engineering, University of Delaware, Newark, DE 19716, USA; Delaware Biotechnology Institute, 15 Innovation Way, Newark, DE 19711, USA.
| |
Collapse
|
4
|
Wagner AP, Chinnathambi S, Titze IR, Sander EA. Vibratory stimulation enhances thyroid epithelial cell function. Biochem Biophys Rep 2016; 8:376-381. [PMID: 28955979 PMCID: PMC5614476 DOI: 10.1016/j.bbrep.2016.10.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Revised: 10/11/2016] [Accepted: 10/13/2016] [Indexed: 02/06/2023] Open
Abstract
The tissues of the body are routinely subjected to various forms of mechanical vibration, the frequency, amplitude, and duration of which can contribute both positively and negatively to human health. The vocal cords, which are in close proximity to the thyroid, may also supply the thyroid with important mechanical signals that modulate hormone production via mechanical vibrations from phonation. In order to explore the possibility that vibrational stimulation from vocalization can enhance thyroid epithelial cell function, FRTL-5 rat thyroid cells were subjected to either chemical stimulation with thyroid stimulating hormone (TSH), mechanical stimulation with physiological vibrations, or a combination of the two, all in a well-characterized, torsional rheometer-bioreactor. The FRTL-5 cells responded to mechanical stimulation with significantly (p<0.05) increased metabolic activity, significantly (p<0.05) increased ROS production, and increased gene expression of thyroglobulin and sodium-iodide symporter compared to un-stimulated controls, and showed an equivalent or greater response than TSH only stimulated cells. Furthermore, the combination of TSH and oscillatory motion produced a greater response than mechanical or chemical stimulation alone. Taken together, these results suggest that mechanical vibrations could provide stimulatory cues that help maintain thyroid function. Thyroid epithelial cells responded to mechanical vibrations similar to those from vocalization. This response was equivalent or greater compared to chemical stimulation. The combination of mechanical and chemical stimulation was synergistic. It may be possible to influence thyroid function with mechanical vibrations.
Collapse
Affiliation(s)
- A P Wagner
- Department of Biomedical Engineering, University of Iowa, IA, USA
| | - S Chinnathambi
- Department of Biomedical Engineering, University of Iowa, IA, USA
| | - I R Titze
- Department of Communication Sciences and Disorders, University of Iowa, IA, USA.,National Center for Voice and Speech, University of Utah, Salt Lake City, UT, USA
| | - E A Sander
- Department of Biomedical Engineering, University of Iowa, IA, USA
| |
Collapse
|
5
|
Christensen MB, Wolchok JC, Klemuk SA, Titze IR. Development of a bilayer ring system for achieving high strain in commercial rheometers. J Biomech 2015; 48:3512-6. [PMID: 26228712 DOI: 10.1016/j.jbiomech.2015.07.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 07/02/2015] [Accepted: 07/13/2015] [Indexed: 11/16/2022]
Abstract
Mechanical stimulation of cell cultures has been shown be an effective means of enhancing ECM production. ECM produced from vocal fold fibroblast cultures has the potential for therapeutic use for vocal fold repair. However, current bioreactor designs generally fail to produce physiological relevant frequency and strain values. Here we present an approach for using commercial oscillatory rheometers and an elastic ring bilayer system to produce physiologically relevant strain values at frequencies in the range of 20-100 Hz. We demonstrate the ability to target specific strain and frequency values by manipulating system parameters, and also show that it is possible to maintain high oscillatory strains for extended periods of time. Such a system could be used to mechanically stimulate cell cultures contained within gel carrier systems and has the potential to be extended to other applications requiring high strains at low frequencies.
Collapse
Affiliation(s)
- Michael B Christensen
- The National Center for Voice and Speech, University of Utah, 136 South Main Street, Suite 320, Salt Lake City, UT 84101, USA; Keck Center for Tissue Engineering, Department of Bioengineering, University of Utah, 36 South Wasatch Drive, Rm 3100, Salt Lake City, UT 84112, USA.
| | - Jeffrey C Wolchok
- Department of Biomedical Engineering, University of Arkansas, 317 Engineering Hall, Fayetteville, AR 72701, USA
| | - Sarah A Klemuk
- The National Center for Voice and Speech, University of Utah, 136 South Main Street, Suite 320, Salt Lake City, UT 84101, USA; Department of Communication Sciences and Disorders, University of Iowa, 324 SHC, Iowa City, IA 52242, USA
| | - Ingo R Titze
- The National Center for Voice and Speech, University of Utah, 136 South Main Street, Suite 320, Salt Lake City, UT 84101, USA
| |
Collapse
|
6
|
A Multiwell Disc Appliance Used to Deliver Quantifiable Accelerations and Shear Stresses at Sonic Frequencies. Processes (Basel) 2014. [DOI: 10.3390/pr2010071] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
7
|
Titze IR, Klemuk SA, Lu X. Adhesion of a Monolayer of Fibroblast Cells to Fibronectin under Sonic Vibrations in a Bioreactor. Ann Otol Rhinol Laryngol 2012; 121:364-74. [DOI: 10.1177/000348941212100602] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Objectives: We examined cell adhesion to a surface under vibrational forces approximating those of phonation. Methods: A monolayer of human fibroblast cells was seeded on a fibronectin-coated glass coverslip, which was attached to either the rotating part or the stationary part of a rheometer-bioreactor. The temperature, humidity, carbon dioxide level, nutrients, and cell seeding density were controlled. The cell density was on the order of 1,000 to 5,000 cells per square millimeter. Target stresses above 1 kPa at an oscillatory frequency of 100 Hz were chosen to reflect conditions of vocal fold tissue vibration. Results: Fibronectin coating provided enough adhesion to support at least 2 kPa of oscillating stress, but only about 0.1 kPa of steady rotational shear. For stresses exceeding those limits, the cells were not able to adhere to the thin film of fibronectin. Conclusions: Cells will adhere to a planar surface under stresses typical of phonation, which provide a more stringent test than adherence in a 3-dimensional matrix. The density of cell seeding on the coverslip played a role in cell–extracellular matrix adhesion, in that the cells adhered to each other more than to the fibronectin coating when the cells were nearly confluent.
Collapse
|
8
|
Gaston J, Quinchia Rios B, Bartlett R, Berchtold C, Thibeault SL. The response of vocal fold fibroblasts and mesenchymal stromal cells to vibration. PLoS One 2012; 7:e30965. [PMID: 22359557 PMCID: PMC3281043 DOI: 10.1371/journal.pone.0030965] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2011] [Accepted: 12/29/2011] [Indexed: 11/19/2022] Open
Abstract
Illumination of cellular changes caused by mechanical forces present within the laryngeal microenvironment may well guide strategies for tissue engineering the vocal fold lamina propria. The purpose of this study was to compare the response of human vocal fold fibroblasts (hVFF) and bone marrow mesenchymal stem cells (BM-MSC) to vibratory stimulus. In order to study these effects, a bioreactor capable of vibrating two cell seeded substrates was developed. The cell seeded substrates contact each other as a result of the sinusoidal frequency, producing a motion similar to the movement of true vocal folds. Utilizing this bioreactor, hVFF and BM-MSC were subjected to 200 Hz vibration and 20% strain for 8 hours. Immunohistochemistry (Ki-67 and TUNEL) was performed to examine cell proliferation and apoptosis respectively, while semi-quantitative RT-PCR was used to assess extracellular matrix related gene expression. HVFF significantly proliferated (p = 0.011) when subjected to 200 Hz vibration and 20% strain, while BM-MSC did not (p = 1.0). A statistically significant increase in apoptosis of BM-MSC (p = 0.0402) was observed under the experimental conditions; however high cell viability (96%) was maintained. HVFF did not have significantly altered apoptosis (p = 0.7849) when subjected to vibration and strain. Semi-quantitative RT-PCR results show no significant differences in expression levels of collagen I (BM-MSC p = 0.1951, hVFF p = v0.3629), fibronectin (BM-MSC p = 0.1951, hVFF p = 0.2513), and TGF-β1 (BM-MSC p = 0.2534, hVFF p = 0.6029) between vibratory and static conditions in either cell type. Finally, smooth muscle actin mRNA was not present in either vibrated or static samples, indicating that no myofibroblast differentiation occurred for either cell type. Together, these results demonstrate that BM-MSC may be a suitable alternative to hVFF for vocal fold tissue engineering. Further investigation into a larger number of gene markers, protein levels, increased number of donors and vibratory conditions are warranted.
Collapse
Affiliation(s)
- Joel Gaston
- Department of Biomedical Engineering, University of Wisconsin Madison, Madison, Wisconsin, United States of America
| | - Beatriz Quinchia Rios
- Division of Otolaryngology Head and Neck Surgery, Department of Surgery, University of Wisconsin Madison, Madison, Wisconsin, United States of America
| | - Rebecca Bartlett
- Division of Otolaryngology Head and Neck Surgery, Department of Surgery, University of Wisconsin Madison, Madison, Wisconsin, United States of America
| | - Craig Berchtold
- Division of Otolaryngology Head and Neck Surgery, Department of Surgery, University of Wisconsin Madison, Madison, Wisconsin, United States of America
| | - Susan L. Thibeault
- Department of Biomedical Engineering, University of Wisconsin Madison, Madison, Wisconsin, United States of America
- Division of Otolaryngology Head and Neck Surgery, Department of Surgery, University of Wisconsin Madison, Madison, Wisconsin, United States of America
- * E-mail:
| |
Collapse
|
9
|
Huttner B, Sutor A, Luegmair G, Rupitsch SJ, Lerch R, Döllinger M. Optical 3-D Metric Measurements of Local Vocal Fold Deformation Characteristics in an In Vitro Setup. IEEE Trans Biomed Eng 2011; 58:2758-66. [DOI: 10.1109/tbme.2011.2130525] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|