Rodriguez Betancourt A, Samal A, Chan HL, Kripfgans OD. Overview of Ultrasound in Dentistry for Advancing Research Methodology and Patient Care Quality with Emphasis on Periodontal/Peri-implant Applications. Z Med Phys 2023; 33:336-386. [PMID: 36922293 PMCID: PMC10517409 DOI: 10.1016/j.zemedi.2023.01.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 12/20/2022] [Accepted: 01/11/2023] [Indexed: 03/14/2023]
Abstract
BACKGROUND Ultrasound is a non-invasive, cross-sectional imaging technique emerging in dentistry. It is an adjunct tool for diagnosing pathologies in the oral cavity that overcomes some limitations of current methodologies, including direct clinical examination, 2D radiographs, and cone beam computerized tomography. Increasing demand for soft tissue imaging has led to continuous improvements on transducer miniaturization and spatial resolution. The aims of this study are (1) to create a comprehensive overview of the current literature of ultrasonic imaging relating to dentistry, and (2) to provide a view onto investigations with immediate, intermediate, and long-term impact in periodontology and implantology. METHODS A rapid literature review was performed using two broad searches conducted in the PubMed database, yielding 576 and 757 citations, respectively. A rating was established within a citation software (EndNote) using a 5-star classification. The broad search with 757 citations allowed for high sensitivity whereas the subsequent rating added specificity. RESULTS A critical review of the clinical applications of ultrasound in dentistry was provided with a focus on applications in periodontology and implantology. The role of ultrasound as a developing dental diagnostic tool was reviewed. Specific uses such as soft and hard tissue imaging, longitudinal monitoring, as well as anatomic and physiological evaluation were discussed. CONCLUSIONS Future efforts should be directed towards the transition of ultrasonography from a research tool to a clinical tool. Moreover, a dedicated effort is needed to introduce ultrasonic imaging to dental education and the dental community to ultimately improve the quality of patient care.
Collapse
Affiliation(s)
| | - Ankita Samal
- Department of Radiology, Medical School, University of Michigan, Ann Arbor, MI, USA
| | - Hsun-Liang Chan
- Department of Periodontology and Oral Medicine, Dental School, University of Michigan, Ann Arbor, MI, USA
| | - Oliver D Kripfgans
- Department of Radiology, Medical School, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
2
|
Hériveaux Y, Nguyen VH, Haïat G. Ultrasonic Evaluation of the Bone-Implant Interface. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:373-396. [DOI: 10.1007/978-3-030-91979-5_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
3
|
Sinjab K, Kripfgans OD, Ou A, Chan HL. Ultrasonographic evaluation of edentulous crestal bone topography: A proof-of-principle retrospective study. Oral Surg Oral Med Oral Pathol Oral Radiol 2022; 133:110-117. [PMID: 34511351 PMCID: PMC8688229 DOI: 10.1016/j.oooo.2021.07.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 05/24/2021] [Accepted: 07/10/2021] [Indexed: 01/03/2023]
Abstract
OBJECTIVE Edentulous crestal bone ridge assessment, an essential task for planning of implant and bone regenerative procedures, is performed through radiographs. Ultrasonography, providing point of care and cross-sectional images without radiation, could be an adjunct for this purpose. The aim was to investigate the feasibility of ultrasound (US) in assessing bone ridge width (BRW) and crestal bone surface quality (CBSQ) compared with cone beam computed tomography (CBCT). STUDY DESIGN Records of patients who were planned for implant placement in at least 1 healed edentulous ridge space with available CBCT and US images were included. The BRWs at 1, 2, and 3 mm from the crest were measured and compared. The CBSQ agreement evaluated using a 3-tier grading system was calculated. RESULTS A total of 45 sites were included. The mean correlation of BRW was 0.97. The mean BRW differences ranged from 0.048 mm (95% confidence interval, -0.69 to 0.78 mm) at the 1-mm level to 0.18 mm (95% confidence interval, -0.92 to 1.3 mm) at the 3-mm level. There was a 91% agreement in CBSQ between the 2 methods. CONCLUSIONS Preliminary data with a limited clinical sample size suggested that US is feasible in evaluating crestal BRW and surface quality assessment compared with CBCT.
Collapse
Affiliation(s)
- Khaled Sinjab
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Oliver D. Kripfgans
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA,Department of Radiology, University of Michigan School of Medicine, Ann Arbor, MI, USA
| | - Alice Ou
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Hsun-Liang Chan
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| |
Collapse
|
4
|
Ultrasound Imaging in Dentistry: A Literature Overview. J Imaging 2021; 7:jimaging7110238. [PMID: 34821869 PMCID: PMC8624259 DOI: 10.3390/jimaging7110238] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 11/07/2021] [Accepted: 11/12/2021] [Indexed: 12/26/2022] Open
Abstract
(1) Background: the frequency with which diagnostic tests are prescribed with exposure to ionizing radiation, a cause of biological damage, has been studied, and with much more attention, patients are subjected to these diagnostic tests for diagnosis and follow-up. This review aimed, given the recent developments of this technology, to evaluate the possible use of ultrasound in different branches of dentistry. The possibility of applying ionizing-radiation-free diagnostic exams in dentistry, overcoming the limits of this application, has led scientific research in this area to obtain interesting results that bode well for the future. (2) Methods: a search for articles on the application of ultrasounds in dentistry was performed using the PubMed electronic database. (3) Results: only 32 studies were included, and these clearly stated that this examination is widely usable and in great progress. (4) Conclusions: regarding the modern application techniques of this diagnostic test, it is essential to consider technological evolution as an objective to reduce the damage and side effects of necessary diagnostic tests. The use of ultrasound in dentistry can represent a valid radiation-free alternative, in certain contexts, to the other most used exams.
Collapse
|
5
|
Hériveaux Y, Vayron R, Fraulob M, Lomami HA, Lenormand C, Haïat G. Assessment of dental implant stability using resonance frequency analysis and quantitative ultrasound methods. J Prosthodont Res 2021; 65:421-427. [PMID: 33177307 DOI: 10.2186/jpr.jpr_d_20_00052] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Purpose Quantitative ultrasound (QUS) and resonance frequency analyses (RFA) are promising methods to assess the stability of dental implants. The aim of this in vivo preclinical study is to compare the results obtained with these two techniques with the bone-implant contact (BIC) ratio, which is the gold standard to assess dental implant stability.Methods Twenty-two identical dental implants were inserted in the tibia and femur of 12 rabbits, which were sacrificed after different healing durations (0, 4, 8 and 13 weeks). For each implant, the ultrasonic indicator (UI) and the implant stability quotient (ISQ) were retrieved just before the animal sacrifice using the QUS and RFA techniques, respectively. Histomorphometric analyses were carried out to estimate the bone-implant contact ratio.Results UI values were found to be better correlated to BIC values (R²=0.47) compared to ISQ values (R²=0.39 for measurements in one direction and R²=0.18 for the other direction), which were shown to be dependent on the direction of measurements. Errors realized on the UI were around 3.3 times lower to the ones realized on the ISQ.Conclusions QUS provide a better estimation of dental implant stability compared to RFA. This study paves the way for the future clinical development of a medical device aiming at assessing dental implant stability in a patient-specific manner. Clinical studies should confirm these results in the future.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Romain Vayron
- Université Polytechnique des Hauts de France, Laboratoire d'Automatique, de Mécanique et d'informatique Industrielles et Humaines, Valenciennes, France
| | - Manon Fraulob
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Hugues Albini Lomami
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Camille Lenormand
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| |
Collapse
|
6
|
Kwak Y, Nguyen VH, Hériveaux Y, Belanger P, Park J, Haïat G. Ultrasonic assessment of osseointegration phenomena at the bone-implant interface using convolutional neural network. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:4337. [PMID: 34241416 DOI: 10.1121/10.0005272] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 05/21/2021] [Indexed: 06/13/2023]
Abstract
Although endosseous implants are widely used in the clinic, failures still occur and their clinical performance depends on the quality of osseointegration phenomena at the bone-implant interface (BII), which are given by bone ingrowth around the BII. The difficulties in ensuring clinical reliability come from the complex nature of this interphase related to the implant surface roughness and the presence of a soft tissue layer (non-mineralized bone tissue) at the BII. The aim of the present study is to develop a method to assess the soft tissue thickness at the BII based on the analysis of its ultrasonic response using a simulation based-convolution neural network (CNN). A large-annotated dataset was constructed using a two-dimensional finite element model in the frequency domain considering a sinusoidal description of the BII. The proposed network was trained by the synthesized ultrasound responses and was validated by a separate dataset from the training process. The linear correlation between actual and estimated soft tissue thickness shows excellent R2 values equal to 99.52% and 99.65% and a narrow limit of agreement corresponding to [ -2.56, 4.32 μm] and [ -15.75, 30.35 μm] of microscopic and macroscopic roughness, respectively, supporting the reliability of the proposed assessment of osseointegration phenomena.
Collapse
Affiliation(s)
- Yunsang Kwak
- Centre National de la Recherche Scientifique, MSME, Université Paris-Est Créteil, Université Gustave Eiffel, F-94010 Creteil, France
| | - Vu-Hieu Nguyen
- University of Paris Est Creteil, Centre National de la Recherche Scientifique, Multiscale Simulation and Modeling Laboratory, F-94010 Creteil, France
| | - Yoann Hériveaux
- Centre National de la Recherche Scientifique, MSME, Université Paris-Est Créteil, Université Gustave Eiffel, F-94010 Creteil, France
| | - Pierre Belanger
- Department of Mechanical Engineering, École de Technologie Supérieure, 1100 Rue Notre-Dame O, Montreal, Quebec, H3C 1K3, Canada
| | - Junhong Park
- Department of Mechanical Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, 04763 Seoul, South Korea
| | - Guillaume Haïat
- Centre National de la Recherche Scientifique, MSME, Université Paris-Est Créteil, Université Gustave Eiffel, F-94010 Creteil, France
| |
Collapse
|
7
|
Fraulob M, Vayron R, Le Cann S, Lecuelle B, Hériveaux Y, Albini Lomami H, Flouzat Lachaniette CH, Haïat G. Quantitative ultrasound assessment of the influence of roughness and healing time on osseointegration phenomena. Sci Rep 2020; 10:21962. [PMID: 33319800 PMCID: PMC7738679 DOI: 10.1038/s41598-020-78806-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 11/23/2020] [Indexed: 12/04/2022] Open
Abstract
The evolution of bone tissue quantity and quality in contact with the surface of orthopedic and dental implants is a strong determinant of the surgical outcome but remains difficult to be assessed quantitatively. The aim of this study was to investigate the performance of a quantitative ultrasound (QUS) method to measure bone-implant interface (BII) properties. A dedicated animal model considering coin-shaped titanium implants with two levels of surface roughness (smooth, Sa = 0.49 µm and rough, Sa = 3.5 µm) allowed to work with a reproducible geometry and a planar interface. The implants were inserted in rabbit femurs and tibiae for 7 or 13 weeks. The ultrasonic response of the BII was measured ex vivo, leading to the determination of the 2-D spatial variations of bone in contact with the implant surface. Histological analysis was carried out to determine the bone-implant contact (BIC) ratio. The amplitude of the echo was significantly higher after 7 weeks of healing time compared to 13 weeks, for both smooth (p < 0.01) and rough (p < 0.05) implants. A negative correlation (R = − 0.63) was obtained between the ultrasonic response and the BIC. This QUS technique is more sensitive to changes of BII morphology compared to histological analyses.
Collapse
Affiliation(s)
- M Fraulob
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - R Vayron
- Laboratoire d'Automatique, de Mécanique et d'informatique Industrielles et Humaines, LAMIH UMR CNRS 8201, Université Polytechnique Hauts de France, 59300, Valenciennes, France
| | - S Le Cann
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - B Lecuelle
- Centre de Recherche BioMédicale, Ecole Nationale Vétérinaire d'Alfort, 7 Avenue du Général de Gaulle, 94700, Maisons-Alfort, France
| | - Y Hériveaux
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - H Albini Lomami
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - C H Flouzat Lachaniette
- INSERM U955, IMRB Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France.,Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France
| | - G Haïat
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France.
| |
Collapse
|
8
|
Hériveaux Y, Nguyen VH, Biwa S, Haïat G. Analytical modeling of the interaction of an ultrasonic wave with a rough bone-implant interface. ULTRASONICS 2020; 108:106223. [PMID: 32771811 DOI: 10.1016/j.ultras.2020.106223] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 04/09/2020] [Accepted: 04/15/2020] [Indexed: 06/11/2023]
Abstract
Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial contact between bone and the implant. The determination of the constitutive law of the BII would be of interest in the context of implant acoustical modeling in order to take into account the imperfect characteristics of the BII. The aim of the present study is to propose an analytical effective model describing the interaction between an ultrasonic wave and a rough BII. To do so, a spring model was considered to determine the equivalent stiffness K of the BII. The stiffness contributions related (i) to the partial contact between the bone and the implant and (ii) to the presence of soft tissues at the BII during the process of osseointegration were assessed independently. K was found to be comprised between 1013 and 1017 N/m3 depending on the roughness and osseointegration of the BII. Analytical values of the reflection and transmission coefficients at the BII were derived from values of K. A good agreement with numerical results obtained through finite element simulation was obtained. This model may be used for future finite element bone-implant models to replace the BII conditions.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, Créteil Cedex 94010, France
| | - Shiro Biwa
- Department of Aeronautics and Astronautics, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8540, Japan
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 94010 Créteil Cedex, France.
| |
Collapse
|
9
|
Fiorillo L, Bocchieri S, Stumpo C, Mastroieni R, Amoroso G, Russo D, D'Amico C, Cervino G. Multicenter clinical trial on dental implants survival rate: a FDS76® study. Minerva Dent Oral Sci 2020. [PMID: 33205924 DOI: 10.23736/s0026-4970.20.04449-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Implantology, thanks to its predictability in oral rehabilitations, has become a widespread method for rehabilitating edentulous patients, offering excellent patient satisfaction. Improving the quality of oral health, especially if rehabilitation involves minimal short and long-term complications, leads to an improvement in the quality of life of our patients. METHODS This clinical study was conducted to evaluate the short and long-term complications (up to 18 months) of implant-prosthetic rehabilitations performed with a new dental implant (FDS76®, Italy). RESULTS The results showed a limited number of complications or implant failures. CONCLUSIONS Knowing the latter could certainly help improve both surgical and dental materials performance.
Collapse
Affiliation(s)
- Luca Fiorillo
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy - .,Multidisciplinary Department of Medical-Surgical and Dental Specialties, Luigi Vanvitelli University of Campania, Naples, Italy -
| | - Salvatore Bocchieri
- Department of Medicine and Surgery, School of Medicine, University of Insubria, Varese, Italy
| | - Chiara Stumpo
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| | - Roberta Mastroieni
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| | - Giulia Amoroso
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| | - Diana Russo
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Luigi Vanvitelli University of Campania, Naples, Italy
| | - Cesare D'Amico
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| | - Gabriele Cervino
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| |
Collapse
|
10
|
Fiorillo L, Bocchieri S, Stumpo C, Mastroieni R, Amoroso G, Russo D, D'Amico C, Cervino G. Multicenter clinical trial on dental implants survival rate: a FDS76® study. Minerva Dent Oral Sci 2020; 70:190-195. [PMID: 33205924 DOI: 10.23736/s2724-6329.20.04449-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND Implantology, thanks to its predictability in oral rehabilitations, has become a widespread method for rehabilitating edentulous patients, offering excellent patient satisfaction. Improving the quality of oral health, especially if rehabilitation involves minimal short and long-term complications, leads to an improvement in the quality of life of our patients. METHODS This clinical study was conducted to evaluate the short and long-term complications (up to 18 months) of implant-prosthetic rehabilitations performed with a new dental implant (FDS76®, Italy). RESULTS The results showed a limited number of complications or implant failures. CONCLUSIONS Knowing the latter could certainly help improve both surgical and dental materials performance.
Collapse
Affiliation(s)
- Luca Fiorillo
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy - .,Multidisciplinary Department of Medical-Surgical and Dental Specialties, Luigi Vanvitelli University of Campania, Naples, Italy -
| | - Salvatore Bocchieri
- Department of Medicine and Surgery, School of Medicine, University of Insubria, Varese, Italy
| | - Chiara Stumpo
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| | - Roberta Mastroieni
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| | - Giulia Amoroso
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| | - Diana Russo
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, Luigi Vanvitelli University of Campania, Naples, Italy
| | - Cesare D'Amico
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| | - Gabriele Cervino
- Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy
| |
Collapse
|
11
|
Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection. BIOMED RESEARCH INTERNATIONAL 2020; 2020:2976067. [PMID: 33102577 PMCID: PMC7568164 DOI: 10.1155/2020/2976067] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 08/14/2020] [Accepted: 08/24/2020] [Indexed: 02/07/2023]
Abstract
The bioengineering and medical and biomedical fields are ever closer, and they manage to obtain surprising results for the development of new devices. The field of simulations and studies in silica has undergone considerable development in recent years, favoring the advancement of medicine. In this manuscript, a study was carried out to evaluate the force distribution on the implant components (In-Kone® Universal) and on the peri-implant tissues subjected to loading. With the finite element analysis and the Von Mises method, it was possible to evaluate this distribution of forces both at 0 degrees (occlusal force) and at 30 degrees; the applied force was 800 N. The obtained results on this new type of connection and on all the implant components are satisfactory; the distribution of forces appears optimal even on the peri-implant tissues. Surely, studies like this help to obtain ever more performing devices, improving both the clinic and the predictability of rehabilitations.
Collapse
|
12
|
Goossens Q, Vancleef S, Leuridan S, Pastrav LC, Mulier M, Desmet W, Vander Sloten J, Denis K. The Use of a Vibro-Acoustic Based Method to Determine the Composite Material Properties of a Replicate Clavicle Bone Model. J Funct Biomater 2020; 11:jfb11040069. [PMID: 32987709 PMCID: PMC7712050 DOI: 10.3390/jfb11040069] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 09/11/2020] [Accepted: 09/21/2020] [Indexed: 11/16/2022] Open
Abstract
Replicate bones are widely used as an alternative for cadaveric bones for in vitro testing. These composite bone models are more easily available and show low inter-specimen variability compared to cadaveric bone models. The combination of in vitro testing with in silico models can provide further insights in the evaluation of the mechanical behavior of orthopedic implants. An accurate numerical representation of the experimental model is important to draw meaningful conclusions from the numerical predictions. This study aims to determine the elastic material constants of a commonly used composite clavicle model by combining acoustic experimental and numerical modal analysis. The difference between the experimental and finite element (FE) predicted natural frequencies was minimized by updating the elastic material constants of the transversely isotropic cortical bone analogue that are provided by the manufacturer. The longitudinal Young's modulus was reduced from 16.00 GPa to 12.88 GPa and the shear modulus was increased from 3.30 GPa to 4.53 GPa. These updated material properties resulted in an average natural frequency difference of 0.49% and a maximum difference of 1.73% between the FE predictions and the experimental results. The presented updated model aims to improve future research that focuses on mechanical simulations with clavicle composite bone models.
Collapse
Affiliation(s)
- Quentin Goossens
- Department of Mechanical Engineering, Biomechanics Section, KU Leuven, 3000 Leuven, Belgium; (S.V.); (S.L.); (L.C.P.); (J.V.S.); (K.D.)
- Correspondence:
| | - Sanne Vancleef
- Department of Mechanical Engineering, Biomechanics Section, KU Leuven, 3000 Leuven, Belgium; (S.V.); (S.L.); (L.C.P.); (J.V.S.); (K.D.)
| | - Steven Leuridan
- Department of Mechanical Engineering, Biomechanics Section, KU Leuven, 3000 Leuven, Belgium; (S.V.); (S.L.); (L.C.P.); (J.V.S.); (K.D.)
| | - Leonard Cezar Pastrav
- Department of Mechanical Engineering, Biomechanics Section, KU Leuven, 3000 Leuven, Belgium; (S.V.); (S.L.); (L.C.P.); (J.V.S.); (K.D.)
| | - Michiel Mulier
- Division of Orthopaedics, University Hospital Leuven, 3000 Leuven, Belgium;
| | - Wim Desmet
- Department of Mechanical Engineering, MSD Section, KU Leuven, 3000 Leuven, Belgium;
| | - Jos Vander Sloten
- Department of Mechanical Engineering, Biomechanics Section, KU Leuven, 3000 Leuven, Belgium; (S.V.); (S.L.); (L.C.P.); (J.V.S.); (K.D.)
| | - Kathleen Denis
- Department of Mechanical Engineering, Biomechanics Section, KU Leuven, 3000 Leuven, Belgium; (S.V.); (S.L.); (L.C.P.); (J.V.S.); (K.D.)
| |
Collapse
|
13
|
Hériveaux Y, Audoin B, Biateau C, Nguyen VH, Haïat G. Ultrasonic Propagation in a Dental Implant. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1464-1473. [PMID: 32139153 DOI: 10.1016/j.ultrasmedbio.2020.01.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 12/23/2019] [Accepted: 01/23/2020] [Indexed: 06/10/2023]
Abstract
Ultrasound techniques can be used to characterize and stimulate dental implant osseointegration. However, the interaction between an ultrasonic wave and the implant-bone interface (IBI) remains unclear. This study-combining experimental and numerical approaches-investigates the propagation of an ultrasonic wave in a dental implant by assessing the amplitude of the displacements along the implant axis. An ultrasonic transducer was excited in a transient regime at 10 MHz. Laser interferometric techniques were employed to measure the amplitude of the displacements, which varied 3.2-8.9 nm along the implant axis. The results demonstrated the propagation of a guided wave mode along the implant axis. The velocity of the first arriving signal was equal to 2110 m.s-1, with frequency components lower than 1 MHz, in agreement with numerical results. Investigating guided wave propagation in dental implants should contribute to improved methods for the characterization and stimulation of the IBI.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| | - Bertrand Audoin
- CNRS, Institut de Mécanique et d'Ingénierie, Talence, France
| | | | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| |
Collapse
|
14
|
Modeling ultrasonic wave propagation in a dental implant - Bone system. J Mech Behav Biomed Mater 2019; 103:103547. [PMID: 31778910 DOI: 10.1016/j.jmbbm.2019.103547] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Revised: 09/04/2019] [Accepted: 11/19/2019] [Indexed: 02/05/2023]
Abstract
The evolution of the bone-implant interface reflects the implant osseointegration and bond strength, thereby determining the overall implant stability in the jawbone. Quantitative ultrasound represents a promising alternative technique to characterize the interfacial integrity, precisely due to the fact that those waves propagate essentially along the bone-implant interface, and are therefore influenced by its state. This study reports a numerical investigation of ultrasonic wave propagation for a commercial implant-jawbone system in which the thickness and mechanical properties of the interfacial layer (corresponding to the interphase) are systematically varied through the application of a rule of mixtures, in order to mimic the evolution from a dominantly soft tissue - like medium up to a fully healed bone. A simple figure of merit is devised in terms of an RMS-like (root mean square) factor based on the implant displacements, that evolves continuously and significantly with the bone "healing" process, thereby providing unequivocal information on the nature of the investigated bone-implant interface. The results show that the wave propagation pattern is primarily dictated by the impedance mismatch rather than by the interface thickness. This study validates the concept of quantitative ultrasonic testing as a sensitive alternative to the widespread resonant frequency analysis, thereby opening the way for future sensitivity analyses that will address more refined bone-implant interface pathologies such as those observed in the clinical realm.
Collapse
|
15
|
Hériveaux Y, Nguyen VH, Geiger D, Haïat G. Elastography of the bone-implant interface. Sci Rep 2019; 9:14163. [PMID: 31578440 PMCID: PMC6775155 DOI: 10.1038/s41598-019-50665-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 09/17/2019] [Indexed: 01/04/2023] Open
Abstract
The stress distribution around endosseous implants is an important determinant of the surgical success. However, no method developed so far to determine the implant stability is sensitive to the loading conditions of the bone-implant interface (BII). The objective of this study is to investigate whether a quantitative ultrasound (QUS) technique may be used to retrieve information on compressive stresses applied to the BII. An acousto-mechanical device was conceived to compress 18 trabecular bovine bone samples onto coin-shaped implants and to measure the ultrasonic response of the BII during compression. The biomechanical behavior of the trabecular bone samples was modeled as Neo-Hookean. The reflection coefficient of the BII was shown to decrease as a function of the stress during the elastic compression of the trabecular bone samples and during the collapse of the trabecular network, with an average slope of −4.82 GPa−1. The results may be explained by an increase of the bone-implant contact ratio and by changes of bone structure occurring during compression. The sensitivity of the QUS response of the BII to compressive stresses opens new paths in the elaboration of patient specific decision support systems allowing surgeons to assess implant stability that should be developed in the future.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Didier Geiger
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France.
| |
Collapse
|
16
|
Gao X, Fraulob M, Haïat G. Biomechanical behaviours of the bone-implant interface: a review. J R Soc Interface 2019; 16:20190259. [PMID: 31362615 PMCID: PMC6685012 DOI: 10.1098/rsif.2019.0259] [Citation(s) in RCA: 113] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/01/2019] [Indexed: 01/09/2023] Open
Abstract
In recent decades, cementless implants have been widely used in clinical practice to replace missing organs, to replace damaged or missing bone tissue or to restore joint functionality. However, there remain risks of failure which may have dramatic consequences. The success of an implant depends on its stability, which is determined by the biomechanical properties of the bone-implant interface (BII). The aim of this review article is to provide more insight on the current state of the art concerning the evolution of the biomechanical properties of the BII as a function of the implant's environment. The main characteristics of the BII and the determinants of implant stability are first introduced. Then, the different mechanical methods that have been employed to derive the macroscopic properties of the BII will be described. The experimental multi-modality approaches used to determine the microscopic biomechanical properties of periprosthetic newly formed bone tissue are also reviewed. Eventually, the influence of the implant's properties, in terms of both surface properties and biomaterials, is investigated. A better understanding of the phenomena occurring at the BII will lead to (i) medical devices that help surgeons to determine an implant's stability and (ii) an improvement in the quality of implants.
Collapse
Affiliation(s)
- Xing Gao
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
- Research Centre for Medical Robotics and Minimally Invasive Surgical Devices, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Manon Fraulob
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| |
Collapse
|
17
|
Hériveaux Y, Nguyen VH, Brailovski V, Gorny C, Haïat G. Reflection of an ultrasonic wave on the bone-implant interface: Effect of the roughness parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:3370. [PMID: 31255165 DOI: 10.1121/1.5109668] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 05/10/2019] [Indexed: 06/09/2023]
Abstract
Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial contact between bone and the implant. The aim of this study is to derive the main determinants of the ultrasonic response of the BII during osseointegration phenomena. The influence of (i) the surface roughness parameters and (ii) the thickness W of a soft tissue layer on the reflection coefficient r of the BII was investigated using a two-dimensional finite element model. When W increases from 0 to 150 μm, r increases from values in the range [0.45; 0.55] to values in the range [0.75; 0.88] according to the roughness parameters. An optimization method was developed to determine the sinusoidal roughness profile leading to the most similar ultrasonic response for all values of W compared to the original profile. The results show that the difference between the ultrasonic responses of the optimal sinusoidal profile and of the original profile was lower to typical experimental errors. This approach provides a better understanding of the ultrasonic response of the BII, which may be used in future numerical simulation realized at the scale of an implant.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vladimir Brailovski
- Department of Mechanical Engineering, École de technologie supérieure, 1100 Notre-Dame Street West, Montreal, Quebec H3C 1K3, Canada
| | - Cyril Gorny
- Laboratoire PIMM (ENSAM, CNRS, CNAM, Hesam Université), 151 Bd de l'Hôpital 75013 Paris (ENSAM), France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
18
|
Rittel D, Dorogoy A, Haïat G, Shemtov-Yona K. Resonant frequency analysis of dental implants. Med Eng Phys 2019; 66:65-74. [PMID: 30837120 DOI: 10.1016/j.medengphy.2019.02.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 12/14/2018] [Accepted: 02/17/2019] [Indexed: 12/29/2022]
Abstract
Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing steady state response analyses using a commercial finite element package. A peri-implant interface, of simultaneously varying stiffness, density and layer thickness is introduced in the numerical 3D model in order to probe the sensitivity of the eigenfrequencies and steady state response to an evolving weakened layer, in an attempt to identify the bone reconstruction around the implant. For the first two modes, the resonant frequency is somewhat insensitive to the healing process, unless the weakened layer is rather large and compliant, like in the very early stages of the implantation. A "Normalized Healing Factor" is devised in the spirit of the Implant Stability Quotient, which can identify the healing process especially at the early stages after implantation. The sensitivity of the resonant frequency analysis to changes of mechanical properties of periprosthetic bone tissue seems relatively weak. Another indicator considering the amplitude as well as the resonance frequency might be more adapted to bone healing estimations. However, these results need to be verified experimentally as well as clinically.
Collapse
Affiliation(s)
- D Rittel
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel.
| | - A Dorogoy
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
| | - G Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-échelle, UMR CNRS 8202, 94010 Créteil Cedex, France
| | - K Shemtov-Yona
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
| |
Collapse
|
19
|
Hériveaux Y, Nguyen VH, Haïat G. Reflection of an ultrasonic wave on the bone-implant interface: A numerical study of the effect of the multiscale roughness. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:488. [PMID: 30075648 DOI: 10.1121/1.5046524] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 06/28/2018] [Indexed: 06/08/2023]
Abstract
Quantitative ultrasound is used to characterize and stimulate osseointegration processes at the bone-implant interface (BII). However, the interaction between an ultrasonic wave and the implant remains poorly understood. This study aims at investigating the sensitivity of the ultrasonic response to the microscopic and macroscopic properties of the BII and to osseointegration processes. The reflection coefficient R of the BII was modeled for different frequencies using a two-dimensional finite element model. The implant surface roughness was modeled by a sinusoidal function with varying amplitude h and spatial frequency L. A soft tissue layer of thickness W was considered between bone tissue and the implant in order to model non-mineralized fibrous tissue. For microscopic roughness, R is shown to increase from around 0.55 until 0.9 when kW increases from 0 to 1 and to be constant for kW > 1, where k is the wavenumber in the implant. These results allow us to show that R depends on the properties of bone tissue located at a distance comprised between 1 and 25 μm from the implant surface. For macroscopic roughness, R is highly dependent on h and this dependence may be explained by phase cancellation and multiple scattering effects for high roughness parameters.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
20
|
Bhaskar V, Chan HL, MacEachern M, Kripfgans OD. Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications. Dentomaxillofac Radiol 2018; 47:20180076. [PMID: 29791198 DOI: 10.1259/dmfr.20180076] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVES Ultrasonography has shown promising diagnostic value in dental implant imaging research; however, exactly how ultrasound was used and at what stage of implant therapy it can be applied has not been systematically evaluated. Therefore, the aim of this review is to investigate potential indications of ultrasound use in the three implant treatment phases, namely planning, intraoperative and post-operative phase. METHODS Eligible manuscripts were searched in major databases with a combination of keywords related to the use of ultrasound imaging in implant therapy. An initial search yielded 414 articles, after further review, 28 articles were finally included for this systematic review. RESULTS Ultrasound was found valuable, though at various development stages, for evaluating (1) soft tissues, (2) hard tissues (3) vital structures and (4) implant stability. B-mode, the main function to image anatomical structures of interest, has been evaluated in pre-clinical and clinical studies. Quantitative ultrasound parameters, e.g. sound speed and amplitude, are being developed to evaluate implant-bone stability, mainly in simulation and pre-clinical studies. Ultrasound could be potentially useful in all three treatment phases. In the planning phase, ultrasound could evaluate vital structures, tissue biotype, ridge width/density, and cortical bone thickness. During surgery, it can provide feedback by identifying vital structures and bone boundary. At follow-up visits, it could evaluate marginal bone level and implant stability. CONCLUSIONS Understanding the current status of ultrasound imaging research for implant therapy would be extremely beneficial for accelerating translational research and its use in dental clinics.
Collapse
Affiliation(s)
| | - Hsun-Liang Chan
- 2 Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry , Ann Arbor, MI , USA
| | - Mark MacEachern
- 3 Taubman Health Sciences Library, University of Michigan , Ann Arbor, MI , USA
| | - Oliver D Kripfgans
- 4 Department of Biomedical Engineering, College of Engineering , Ann Arbor, MI , USA.,5 Department of Radiology, University of Michigan Medical School , Ann Arbor, MI , USA
| |
Collapse
|
21
|
Vayron R, Nguyen VH, Lecuelle B, Haiat G. Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis. Clin Implant Dent Relat Res 2018; 20:470-478. [PMID: 29770562 DOI: 10.1111/cid.12622] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 02/22/2018] [Accepted: 04/17/2018] [Indexed: 12/22/2022]
Abstract
BACKGROUND Resonance frequency analyses and quantitative ultrasound methods have been suggested to assess dental implant primary stability. PURPOSE The purpose of this study was to compare the results obtained using these two techniques applied to the same dental implants inserted in various bone phantoms. MATERIALS AND METHODS Different values of trabecular bone density and cortical thickness were considered to assess the effect of bone quality on the respective indicators (UI and ISQ). The effect of the implant insertion depth and of the final drill diameter was also investigated. RESULTS ISQ values increase and UI values decrease as a function of trabecular density, cortical thickness and the screwing of the implant. When the implant diameter varies, the UI values are significantly different for all final drill diameters (except for two), while the ISQ values are similar for all final drill diameters lower than 3.2 mm and higher than 3.3 mm. The error on the estimation of parameters with the QUS device is between 4 and 8 times lower compared to that made with the RFA technique. CONCLUSIONS The results show that ultrasound technique provides a better estimation of different parameters related to the implant stability compared to the RFA technique.
Collapse
Affiliation(s)
- Romain Vayron
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| | - Vu-Hieu Nguyen
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| | - Benoît Lecuelle
- Centre de Recherche BioMédicale, Ecole Nationale Vétérinaire d'Alfort, 7 Avenue du Général de Gaulle, 94700 Maisons-Alfort, France
| | - Guillaume Haiat
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| |
Collapse
|
22
|
Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration. SENSORS 2018; 18:s18051397. [PMID: 29724028 PMCID: PMC5982662 DOI: 10.3390/s18051397] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 04/09/2018] [Accepted: 04/20/2018] [Indexed: 12/31/2022]
Abstract
Dental implants are widely used in the clinic. However, there remain risks of failure, which depend on the implant stability. The aim of this paper is to compare two methods based on resonance frequency analysis (RFA) and on quantitative ultrasound (QUS) and that aim at assessing implant stability. Eighty-one identical dental implants were inserted in the iliac crests of 11 sheep. The QUS and RFA measurements were realized after different healing times (0, 5, 7, and 15 weeks). The results obtained with the QUS (respectively RFA) method were significantly different when comparing two consecutive healing time for 97% (respectively, 18%) of the implants. The error made on the estimation of the healing time when analyzing the results obtained with the QUS technique was around 10 times lower than that made when using the RFA technique. The results corresponding to the dependence of the ISQ versus healing time were significantly different when comparing two directions of RFA measurement. The results show that the QUS method allows a more accurate determination of the evolution of dental implant stability when compared to the RFA method. This study paves the way towards the development of a medical device, thus providing a decision support system to dental surgeons.
Collapse
|
23
|
Ultrasonic characterization and multiscale analysis for the evaluation of dental implant stability: A sensitivity study. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2017.12.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|