1
|
Hughes ML. Electrically evoked compound action potential polarity sensitivity, refractory-recovery, and behavioral multi-pulse integration as potential indices of neural health in cochlear-implant recipients. Hear Res 2023; 433:108764. [PMID: 37062161 PMCID: PMC10322179 DOI: 10.1016/j.heares.2023.108764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 03/26/2023] [Accepted: 04/05/2023] [Indexed: 04/18/2023]
Affiliation(s)
- Michelle L Hughes
- University of Nebraska-Lincoln, Dept. of Special Education and Communication Disorders, 276 Barkley Memorial Center, 4072 East Campus Loop, Lincoln, NE, 68583, USA.
| |
Collapse
|
2
|
Jahn KN, DeVries L, Arenberg JG. Recovery from forward masking in cochlear implant listeners: Effects of age and the electrode-neuron interface. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:1633. [PMID: 33765782 PMCID: PMC8267874 DOI: 10.1121/10.0003623] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 02/12/2021] [Accepted: 02/12/2021] [Indexed: 06/12/2023]
Abstract
Older adults exhibit deficits in auditory temporal processing relative to younger listeners. These age-related temporal processing difficulties may be further exacerbated in older adults with cochlear implant (CIs) when CI electrodes poorly interface with their target auditory neurons. The aim of this study was to evaluate the potential interaction between chronological age and the estimated quality of the electrode-neuron interface (ENI) on psychophysical forward masking recovery, a measure that reflects single-channel temporal processing abilities. Fourteen CI listeners (age 15 to 88 years) with Advanced Bionics devices participated. Forward masking recovery was assessed on two channels in each ear (i.e., the channels with the lowest and highest signal detection thresholds). Results indicated that the rate of forward masking recovery declined with advancing age, and that the effect of age was more pronounced on channels estimated to interface poorly with the auditory nerve. These findings indicate that the quality of the ENI can influence the time course of forward masking recovery for older CI listeners. Channel-to-channel variability in the ENI likely interacts with central temporal processing deficits secondary to auditory aging, warranting further study of programming and rehabilitative approaches tailored to older listeners.
Collapse
Affiliation(s)
- Kelly N Jahn
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington 98105, USA
| | - Lindsay DeVries
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Julie G Arenberg
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington 98105, USA
| |
Collapse
|
3
|
Bissmeyer SRS, Hossain S, Goldsworthy RL. Perceptual learning of pitch provided by cochlear implant stimulation rate. PLoS One 2020; 15:e0242842. [PMID: 33270735 PMCID: PMC7714175 DOI: 10.1371/journal.pone.0242842] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 11/10/2020] [Indexed: 11/19/2022] Open
Abstract
Cochlear implant users hear pitch evoked by stimulation rate, but discrimination diminishes for rates above 300 Hz. This upper limit on rate pitch is surprising given the remarkable and specialized ability of the auditory nerve to respond synchronously to stimulation rates at least as high as 3 kHz and arguably as high as 10 kHz. Sensitivity to stimulation rate as a pitch cue varies widely across cochlear implant users and can be improved with training. The present study examines individual differences and perceptual learning of stimulation rate as a cue for pitch ranking. Adult cochlear implant users participated in electrode psychophysics that involved testing once per week for three weeks. Stimulation pulse rate discrimination was measured in bipolar and monopolar configurations for apical and basal electrodes. Base stimulation rates between 100 and 800 Hz were examined. Individual differences were quantified using psychophysically derived metrics of spatial tuning and temporal integration. This study examined distribution of measures across subjects, predictive power of psychophysically derived metrics of spatial tuning and temporal integration, and the effect of training on rate discrimination thresholds. Psychophysical metrics of spatial tuning and temporal integration were not predictive of stimulation rate discrimination, but discrimination thresholds improved at lower frequencies with training. Since most clinical devices do not use variable stimulation rates, it is unknown to what extent recipients may learn to use stimulation rate cues if provided in a clear and consistent manner.
Collapse
Affiliation(s)
- Susan R. S. Bissmeyer
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, United States of America
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| | - Shaikat Hossain
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| | - Raymond L. Goldsworthy
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, United States of America
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| |
Collapse
|
4
|
Brochier T, Guérit F, Deeks JM, Garcia C, Bance M, Carlyon RP. Evaluating and Comparing Behavioural and Electrophysiological Estimates of Neural Health in Cochlear Implant Users. J Assoc Res Otolaryngol 2020; 22:67-80. [PMID: 33150541 PMCID: PMC7822986 DOI: 10.1007/s10162-020-00773-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 10/14/2020] [Indexed: 12/12/2022] Open
Abstract
Variations in neural health along the cochlea can degrade the spectral and temporal representation of sounds conveyed by cochlear implants (CIs). We evaluated and compared one electrophysiological measure and two behavioural measures that have been proposed as estimates of neural health patterns, in order to explore the extent to which the different measures provide converging and consistent neural health estimates. All measures were obtained from the same 11 users of the Cochlear Corporation CI. The two behavioural measures were multipulse integration (MPI) and the polarity effect (PE), both measured on each of seven electrodes per subject. MPI was measured as the difference between thresholds at 80 pps and 1000 pps, and PE as the difference in thresholds between cathodic- and anodic-centred quadraphasic (QP) 80-pps pulse trains. It has been proposed that good neural health corresponds to a large MPI and to a large negative PE (lower thresholds for cathodic than anodic pulses). The electrophysiological measure was the effect of interphase gap (IPG) on the offset of the ECAP amplitude growth function (AGF), which has been correlated with spiral ganglion neuron density in guinea pigs. This 'IPG offset' was obtained on the same subset of electrodes used for the behavioural measures. Despite high test-retest reliability, there were no significant correlations between the neural health estimates for either within-subject comparisons across the electrode array, or between-subject comparisons of the means. A phenomenological model of a population of spiral ganglion neurons was then used to investigate physiological mechanisms that might underlie the different neural health estimates. The combined experimental and modelling results provide evidence that PE, MPI and IPG offset may reflect different characteristics of the electrode-neural interface.
Collapse
Affiliation(s)
- Tim Brochier
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK. .,Cambridge Hearing Group, Cambridge University Hospitals Foundation Trust, Hills Road, Cambridge, CB2 0QQ, UK.
| | - François Guérit
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - John M Deeks
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - Charlotte Garcia
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge University Hospitals Foundation Trust, Hills Road, Cambridge, CB2 0QQ, UK
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| |
Collapse
|
5
|
Abstract
OBJECTIVES Pitch is poorly perceived by cochlear implant (CI) users. However, as it is not well understood how pitch is encoded with electric stimulation, improving pitch representation with a CI is challenging. Changes in place of stimulation along the cochlea have been described as changes in pitch and can be accurately ranked by CI users. However, it remains unknown if place-pitch can be used to encode musical intervals, which are a necessary attribute of pitch. The objective of these experiments is to determine if place-pitch coding can be used to represent musical intervals with a CI. DESIGN In the first experiment, 10 CI users and 10 normal hearing (NH) controls were tested on their sensitivity to changes in the semitone spacing between each of the notes in the melody "Happy Birthday." The changes were implemented by uniformly expanding or compressing the frequency differences between each note in the melody. The participant's task was to scale how "out-of-tune" the melody was for various semitone spacing distortions. The notes were represented by pure-tones ≥440 Hz to minimize potential useful temporal information from the stimuli. A second experiment replicated the first experiment using single-sided deafened CI users allowing for a within-subject control. A third experiment verified that the CI users who participated in Experiment 1 were each able to determine pitch direction reliably. RESULTS Unlike NH listeners, CI listeners often ranked all distortions of interval spacing similarly in both the first and second experiment, and no effect of interval spacing was detected across CI users. Some participants found distorted interval spacings to be less out-of-tune than the nominally correct interval spacings. However, these patterns were inconsistent across listeners. Although performance was better for the NH listeners, the third experiment demonstrated that the CI listeners were able to reliably identify changes in pitch direction from place-pitch coding. CONCLUSIONS The data suggest that place-pitch intervals are not properly represented through a CI sound processor. Some limited support is found for place-pitch being useful for interval encoding as some participants demonstrated improved ratings for certain interval distortions. Presumably the interval representation for these participants could be improved by a change to the frequencies represented by each electrode. However, as these patterns vary across listeners, there is not a universal correction to frequency representation that will solve this issue. As results are similar for single-sided deafened CI users, the limitations in ratings are likely not limited by an eroded representation of the melody caused by an extended duration of deafness.
Collapse
|
6
|
Forward masking patterns by low and high-rate stimulation in cochlear implant users: Differences in masking effectiveness and spread of neural excitation. Hear Res 2020; 389:107921. [PMID: 32097828 DOI: 10.1016/j.heares.2020.107921] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 01/15/2020] [Accepted: 02/13/2020] [Indexed: 11/20/2022]
Abstract
The goal of the present study was to compare forward masking patterns by stimulation of low and high rates in cochlear implant users. Postlingually deafened Cochlear Nucleus® device users participated in the study. In experiment 1, two maskers of different rates (250 and 1000 pulses per second) were set at levels that produced equal masking for a probe presented at the same electrode as the maskers. This aligned the two masking functions at the on-site probe location. Then their forward masking patterns for the far probes were compared. Results showed that slope of the masked probe-threshold decay as a function of probe-masker separation was steeper for the high-rate than the low-rate masker. A linear model indicated that this difference in spread of neural excitation (SOE) was accounted for by two factors that were not correlated with each other. One factor was that the low-rate masker required a considerably higher current level to be equally effective in masking as the high-rate masker. The second factor was the effect of stimulation rate on loudness, i.e., integration of multiple pulses. This was consistent with our hypothesis that if an increase in stimulation rate does not result in an increased total neural response, then it is unlikely that the change in rate would change spatial distribution of the neural activity. Interestingly, the difference in masking effectiveness of the maskers predicted subjects' speech recognition. Poorer performers were those who showed more comparable masking effects by maskers of different rates. The difference in the masking effectiveness may indirectly measure the auditory neurons' excitability, which predicts speech recognition. In experiment 2, SOE of the high-rate and low-rate maskers were compared at a level that is clinically relevant, i.e., equal loudness. At equal loudness, high-rate stimulation not only produced an overall greater amount of forward masking, but also a shallower decay of masking with probe-masker separation (wider SOE), compared to low rate. The difference in SOE was the opposite to the findings from experiment 1. Whether the maskers were calibrated for equal masking or loudness, the absolute current level was always higher for the low-rate masker, which suggests that the SOE patterns cannot be explained by current spread alone. The fact that high-rate stimulation produced greater masking and wider SOE at equal loudness may explain why using high stimulation rates has not produced consistent benefits for speech recognition, and why lowering stimulation rate from the manufacturer's default sometimes results in improved speech recognition for subjects.
Collapse
|
7
|
Residual Cochlear Function in Adults and Children Receiving Cochlear Implants: Correlations With Speech Perception Outcomes. Ear Hear 2019; 40:577-591. [PMID: 30169463 DOI: 10.1097/aud.0000000000000630] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES Variability in speech perception outcomes with cochlear implants remains largely unexplained. Recently, electrocochleography, or measurements of cochlear potentials in response to sound, has been used to assess residual cochlear function at the time of implantation. Our objective was to characterize the potentials recorded preimplantation in subjects of all ages, and evaluate the relationship between the responses, including a subjective estimate of neural activity, and speech perception outcomes. DESIGN Electrocochleography was recorded in a prospective cohort of 284 candidates for cochlear implant at University of North Carolina (10 months to 88 years of ages). Measurement of residual cochlear function called the "total response" (TR), which is the sum of magnitudes of spectral components in response to tones of different stimulus frequencies, was obtained for each subject. The TR was then related to results on age-appropriate monosyllabic word score tests presented in quiet. In addition to the TR, the electrocochleography results were also assessed for neural activity in the forms of the compound action potential and auditory nerve neurophonic. RESULTS The TR magnitude ranged from a barely detectable response of about 0.02 µV to more than 100 µV. In adults (18 to 79 years old), the TR accounted for 46% of variability in speech perception outcome by linear regression (r = 0.46; p < 0.001). In children between 6 and 17 years old, the variability accounted for was 36% (p < 0.001). In younger children, the TR accounted for less of the variability, 15% (p = 0.012). Subjects over 80 years old tended to perform worse for a given TR than younger adults at the 6-month testing interval. The subjectively assessed neural activity did not increase the information compared with the TR alone, which is primarily composed of the cochlear microphonic produced by hair cells. CONCLUSIONS The status of the auditory periphery, particularly of hair cells rather than neural activity, accounts for a large fraction of variability in speech perception outcomes in adults and older children. In younger children, the relationship is weaker, and the elderly differ from other adults. This simple measurement can be applied with high throughput so that peripheral status can be assessed to help manage patient expectations, create individually-tailored treatment plans, and identify subjects performing below expectations based on residual cochlear function.
Collapse
|
8
|
Pulse-rate discrimination deficit in cochlear implant users: is the upper limit of pitch peripheral or central? Hear Res 2018; 371:1-10. [PMID: 30423498 DOI: 10.1016/j.heares.2018.10.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Revised: 10/04/2018] [Accepted: 10/31/2018] [Indexed: 11/20/2022]
Abstract
Cochlear implant (CI) users do not reliably associate an increase in pulse rate above 300 pulses per second (pps) with an increase in pitch. The locus of this upper limit of pitch remains unknown. The present study tested the hypothesis that this deficit resides at least initially at the auditory nerve. The hypothesis was tested by comparing pulse rate discrimination in different neural excitation patterns, in which a large versus small population of auditory nerve fibers was activated. If poorer pulse rate discrimination was found under conditions where narrower spread of neural excitation (SOE) was anticipated where a relatively small neural population was activated, then it would support the hypothesis that the rate processing deficit found in CI users is related to peripheral neural degeneration. Nine listeners (12 ears) implanted with the Cochlear Americas Nucleus® devices participated in the study. Different SOE conditions were created by (1) selecting electrodes that showed narrow versus broad forward-masked psychophysical spatial tuning curves, and (2) by measuring these electrodes in monopolar (MP) and narrow bipolar (BP0) electrode configurations. Rate discrimination difference limen (DL) was measured at the selected electrodes in two electrode configurations at three base rates (200, 300 and 500 pps). Consistent with the prediction, group mean DL was better (1) at stimulation sites measured with broader tuning, and (2) in MP relative to BP stimulation. These effects were more salient at the more challenging base rates. There was a weak relationship between rate discrimination (above thresholds) and the effect of rate on detection thresholds. Finally, rate discrimination at rates above the known upper limit (i.e., 500 pps) was correlated with duration of deafness and highly predicted the subjects' speech recognition performance in noise. These findings support that pulse rate discrimination depends, at least partially, on neural conditions at the auditory periphery and this peripheral limit predicts speech recognition outcomes with a CI.
Collapse
|
9
|
Di Stadio A, Ralli M, Ishai R, D'Ascanio L, Trabalzini F, Della Volpe A, Babighian G, Ricci G. Nucleolus vs Nucleus Count for Identifying Spiral Ganglion in Human Temporal Bone. J Int Adv Otol 2018; 14:181-189. [PMID: 30256195 DOI: 10.5152/iao.2018.5517] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVES Spiral ganglion (SG) counting is used in experimental studies conducted on age-, noise-, and drug-induced sensorineural hearing loss, as well as in the assessment of cochlear implant performances. Different methods of counting have been reported, but no definite standardization of such procedure has been published. The aim of our study is to identify the best method to count human spiral ganglions (SGs). MATERIALS AND METHODS By identification of nuclei or nucleoli as described by Schucknect, seven researchers with different experience levels counted SGs in 123 human temporal bones (TBs). Data on time of post-mortem bone removal post-mortem, methods of specimen's fixation, decalcification, and coloration were collected to test their possible influence on human tissue. Percentage, two-tailed t-test, Spearman's test, and one-way ANOVA were used to analyze the data. RESULTS Nucleoli were identified in 61% of cases, whereas nuclei were recognized in 100% of cases (p<0.005). Nucleoli presence in all four segments in the same temporal bone (TB) was observed in 69 cases (92%), whereas nuclei were identified in all four segments in 103 cases (83.7%) (p<0.001). The junior investigators requested a double check by the seniors in 25 (20.3%) cases for identifying and counting nucleoli, whereas the senior researchers showed no doubts in their identification and count. The only parameter positively affecting nucleoli identification in tissue preparation was bone removal for <12 h with respect to longer post-mortem time (p<0.001). CONCLUSION We suggest counting nuclei, rather than nucleoli, for spiral ganglion computation because of easier recognition of nuclei, especially in case of investigator's limited experience.
Collapse
Affiliation(s)
- Arianna Di Stadio
- University of Perugia, Permanent Temporal Bone Laboratory, Perugia, Italy
| | - Massimo Ralli
- University La Sapienza, Department of Oral and Maxillofacial Sciences, Rome, Italy
| | - Reuven Ishai
- Toronto General Hospital, Otolaryngology Department, Toronto, Canada
| | - Luca D'Ascanio
- "Carlo Poma" Civil Hospital, Department of Otolaryngology-Head and Neck Surgery, Mantova, Italy
| | | | - Antonio Della Volpe
- Santobono-Posillipon Hospital, Otology and Cochlear Implant Unit, Naples, Italy
| | - Gregorio Babighian
- University of Perugia, Permanent Temporal Bone Laboratory, Perugia, Italy
| | - Giampietro Ricci
- University of Perugia, Otolaryngology Department, Perugia, Italy
| |
Collapse
|
10
|
Zhou N, Dong L. Evaluating Multipulse Integration as a Neural-Health Correlate in Human Cochlear-Implant Users: Relationship to Psychometric Functions for Detection. Trends Hear 2018; 21:2331216517690108. [PMID: 28150534 PMCID: PMC5308440 DOI: 10.1177/2331216517690108] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
In electrical hearing, multipulse integration (MPI) describes the rate at which detection threshold decreases with increasing stimulation rate in a fixed-duration pulse train. In human subjects, MPI has been shown to be dependent on the psychophysically estimated spread of neural excitation at a high stimulation rate, with broader spread predicting greater integration. The first aim of the present study was to replicate this finding using alternative methods for measuring MPI and spread of neural excitation. The second aim was to test the hypothesis that MPI is related to the slope of the psychometric function for detection. Specifically, a steep d' versus stimulus level function would predict shallow MPI since the amount of current reduction necessary to compensate for an increase in stimulation rate to maintain threshold would be small. The MPI function was measured by obtaining adaptive detection thresholds at 160 and 640 pulses per second. Spread of neural excitation was measured by forward-masked psychophysical tuning curves. All psychophysical testing was performed in a monopolar stimulation mode (MP 1 + 2). Results showed that MPI was correlated with the slopes of the tuning curves, with broader tuning predicting steeper MPI, confirming the earlier finding. However, there was no relationship between MPI and the slopes of the psychometric functions. These results suggest that a broad stimulation of the cochlea facilitates MPI. MPI however is not related to the estimated neural excitation growth with current level near the behavioral threshold, at least in monopolar stimulation.
Collapse
Affiliation(s)
- Ning Zhou
- 1 Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, USA
| | - Lixue Dong
- 1 Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, USA
| |
Collapse
|
11
|
Evaluating Multipulse Integration as a Neural-Health Correlate in Human Cochlear Implant Users: Effects of Stimulation Mode. J Assoc Res Otolaryngol 2017; 19:99-111. [PMID: 29086155 DOI: 10.1007/s10162-017-0643-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Accepted: 10/09/2017] [Indexed: 01/04/2023] Open
Abstract
Previous psychophysical studies have shown that a steep detection-threshold-versus-stimulation-rate function (multipulse integration; MPI) is associated with laterally positioned electrodes producing a broad neural excitation pattern. These findings are consistent with steep MPI depending on either a certain width of neural excitation allowing a large population of neurons operating at a low point on their dynamic range to respond to an increase in stimulation rate or a certain slope of excitation pattern that allows recruitment of neurons at the excitation periphery. Results of the current study provide additional support for these mechanisms by demonstrating significantly flattened MPI functions in narrow bipolar than monopolar stimulation. The study further examined the relationship between the steepness of the psychometric functions for detection (d' versus log current level) and MPI. In contrast to findings in monopolar stimulation, current data measured in bipolar stimulation suggest that steepness of the psychometric functions explained a moderate amount of the across-site variance in MPI. Steepness of the psychometric functions, however, cannot explain why MPI flattened in bipolar stimulation, since slopes of the psychometric functions were comparable in the two stimulation modes. Lastly, our results show that across-site mean MPI measured in monopolar and bipolar stimulation correlated with speech recognition in opposite signs, with steeper monopolar MPI being associated with poorer performance but steeper bipolar MPI being associated with better performance. If steeper MPI requires broad stimulation of the cochlea, the correlation between monopolar MPI and speech recognition can be interpreted as the detrimental effect of poor spectral resolution on speech recognition. Assuming bipolar stimulation produces narrow excitation, and MPI measured in bipolar stimulation reflects primarily responses of the on-site neurons, the correlation between bipolar MPI and speech recognition can be understood in light of the importance of neural survival for speech recognition.
Collapse
|
12
|
Chatterjee M, Kulkarni AM. Recovery from forward masking in cochlear implant listeners depends on stimulation mode, level, and electrode location. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:3190. [PMID: 28682084 PMCID: PMC5482749 DOI: 10.1121/1.4983156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 03/27/2017] [Accepted: 04/25/2017] [Indexed: 06/07/2023]
Abstract
Psychophysical recovery from forward masking was measured in adult cochlear implant users of CochlearTM and Advanced BionicsTM devices, in monopolar and in focused (bipolar and tripolar) stimulation modes, at four electrode sites across the arrays, and at two levels (loudness balanced across modes and electrodes). Results indicated a steeper psychophysical recovery from forward masking in monopolar over bipolar and tripolar modes, modified by differential effects of electrode and level. The interactions between factors varied somewhat across devices. It is speculated that psychophysical recovery from forward masking may be driven by different populations of neurons in the different modes, with a broader stimulation pattern resulting in a greater likelihood of response by healthier and/or faster-recovering neurons within the stimulated population. If a more rapid recovery from prior stimulation reflects responses of neurons not necessarily close to the activating site, the spectral pattern of the incoming acoustic signal may be distorted. These results have implications for speech processor implementations using different degrees of focusing of the electric field. The primary differences in the shape of the recovery function were observed in the earlier portion (between 2 and 45 ms) of recovery, which is significant in terms of the speech envelope.
Collapse
Affiliation(s)
- Monita Chatterjee
- Auditory Prostheses & Perception Laboratory, Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Aditya M Kulkarni
- Auditory Prostheses & Perception Laboratory, Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| |
Collapse
|