1
|
Nyirjesy SC, Lewis JH, Hallak D, Conroy S, Moberly AC, Tamati TN. Evaluating Listening Effort in Unilateral, Bimodal, and Bilateral Cochlear Implant Users. Otolaryngol Head Neck Surg 2024; 170:1147-1157. [PMID: 38104319 DOI: 10.1002/ohn.609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 10/24/2023] [Accepted: 11/24/2023] [Indexed: 12/19/2023]
Abstract
OBJECTIVE Evaluate listening effort (LE) in unilateral, bilateral, and bimodal cochlear implant (CI) users. Establish an easy-to-implement task of LE that could be useful for clinical decision making. STUDY DESIGN Prospective cohort study. SETTING Tertiary neurotology center. METHODS The Sentence Final Word Identification and Recall Task, an established measure of LE, was modified to include challenging listening conditions (multitalker babble, gender, and emotional variation; test), in addition to single-talker sentences (control). Participants listened to lists of sentences in each condition and recalled the last word of each sentence. LE was quantified by percentage of words correctly recalled and was compared across conditions, across CI groups, and within subjects (best aided vs monaural). RESULTS A total of 24 adults between the ages of 37 and 82 years enrolled, including 4 unilateral CI users (CI), 10 bilateral CI users (CICI), and 10 bimodal CI users (CIHA). Task condition impacted LE (P < .001), but hearing configuration and listener group did not (P = .90). Working memory capacity and contralateral hearing contributed to individual performance. CONCLUSION This study adds to the growing body of literature on LE in challenging listening conditions for CI users and demonstrates feasibility of a simple behavioral task that could be implemented clinically to assess LE. This study also highlights the potential benefits of bimodal hearing and individual hearing and cognitive factors in understanding individual differences in performance, which will be evaluated through further research.
Collapse
Affiliation(s)
- Sarah C Nyirjesy
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA
| | - Jessica H Lewis
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA
- Department of Speech and Hearing Science, The Ohio State University, Columbus, Ohio, USA
| | - Diana Hallak
- Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA
| | - Sara Conroy
- Department of Biomedical Informatics, Center for Biostatistics, The Ohio State University, Columbus, Ohio, USA
| | - Aaron C Moberly
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Terrin N Tamati
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| |
Collapse
|
2
|
Tamati TN, Jebens A, Başkent D. Lexical effects on talker discrimination in adult cochlear implant usersa). THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:1631-1640. [PMID: 38426835 PMCID: PMC10908561 DOI: 10.1121/10.0025011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 02/06/2024] [Accepted: 02/07/2024] [Indexed: 03/02/2024]
Abstract
The lexical and phonological content of an utterance impacts the processing of talker-specific details in normal-hearing (NH) listeners. Adult cochlear implant (CI) users demonstrate difficulties in talker discrimination, particularly for same-gender talker pairs, which may alter the reliance on lexical information in talker discrimination. The current study examined the effect of lexical content on talker discrimination in 24 adult CI users. In a remote AX talker discrimination task, word pairs-produced either by the same talker (ST) or different talkers with the same (DT-SG) or mixed genders (DT-MG)-were either lexically easy (high frequency, low neighborhood density) or lexically hard (low frequency, high neighborhood density). The task was completed in quiet and multi-talker babble (MTB). Results showed an effect of lexical difficulty on talker discrimination, for same-gender talker pairs in both quiet and MTB. CI users showed greater sensitivity in quiet as well as less response bias in both quiet and MTB for lexically easy words compared to lexically hard words. These results suggest that CI users make use of lexical content in same-gender talker discrimination, providing evidence for the contribution of linguistic information to the processing of degraded talker information by adult CI users.
Collapse
Affiliation(s)
- Terrin N Tamati
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Ave S, Nashville, Tennessee 37232, USA
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Almut Jebens
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Deniz Başkent
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Research School of Behavioral and Cognitive Neurosciences, Graduate School of Medical Sciences, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
3
|
Babaoğlu G, Rachman L, Ertürk P, Özkişi Yazgan B, Sennaroğlu G, Gaudrain E, Başkent D. Perception of voice cues in school-age children with hearing aids. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:722-741. [PMID: 38284822 DOI: 10.1121/10.0024356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 12/26/2023] [Indexed: 01/30/2024]
Abstract
The just-noticeable differences (JNDs) of the voice cues of voice pitch (F0) and vocal-tract length (VTL) were measured in school-aged children with bilateral hearing aids and children and adults with normal hearing. The JNDs were larger for hearing-aided than normal-hearing children up to the age of 12 for F0 and into adulthood for all ages for VTL. Age was a significant factor for both groups for F0 JNDs, but only for the hearing-aided group for VTL JNDs. Age of maturation was later for F0 than VTL. Individual JNDs of the two groups largely overlapped for F0, but little for VTL. Hearing thresholds (unaided or aided, 500-400 Hz, overlapping with mid-range speech frequencies) did not correlate with the JNDs. However, extended low-frequency hearing thresholds (unaided, 125-250 Hz, overlapping with voice F0 ranges) correlated with the F0 JNDs. Hence, age and hearing status differentially interact with F0 and VTL perception, and VTL perception seems challenging for hearing-aided children. On the other hand, even children with profound hearing loss could do the task, indicating a hearing aid benefit for voice perception. Given the significant age effect and that for F0 the hearing-aided children seem to be catching up with age-typical development, voice cue perception may continue developing in hearing-aided children.
Collapse
Affiliation(s)
- Gizem Babaoğlu
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, The Netherlands
| | - Laura Rachman
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, The Netherlands
| | - Pınar Ertürk
- Department of Audiology, Health Sciences Institute, Hacettepe University, Ankara, Turkey
| | - Başak Özkişi Yazgan
- Department of Audiology, Health Sciences Institute, Hacettepe University, Ankara, Turkey
| | - Gonca Sennaroğlu
- Department of Audiology, Health Sciences Institute, Hacettepe University, Ankara, Turkey
| | - Etienne Gaudrain
- Lyon Neuroscience Research Center, CNRS UMR5292, Inserm U1028, Université Lyon 1, Lyon, France
| | - Deniz Başkent
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, The Netherlands
| |
Collapse
|
4
|
Zaltz Y. The effect of stimulus type and testing method on talker discrimination of school-age children. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:2611. [PMID: 37129674 DOI: 10.1121/10.0017999] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Accepted: 04/12/2023] [Indexed: 05/03/2023]
Abstract
Efficient talker discrimination (TD) improves speech understanding under multi-talker conditions. So far, TD of children has been assessed using various testing parameters, making it difficult to draw comparative conclusions. This study explored the effects of the stimulus type and variability on children's TD. Thirty-two children (7-10 years old) underwent eight TD assessments with fundamental frequency + formant changes using an adaptive procedure. Stimuli included consonant-vowel-consonant words or three-word sentences and were either fixed by run or by trial (changing throughout the run). Cognitive skills were also assessed. Thirty-one adults (18-35 years old) served as controls. The results showed (1) poorer TD for the fixed-by-trial than the fixed-by-run method, with both stimulus types for the adults but only with the words for the children; (2) poorer TD for the words than the sentences with the fixed-by-trial method only for the children; and (3) significant correlations between the children's age and TD. These results support a developmental trajectory in the use of perceptual anchoring for TD and in its reliance on comprehensive acoustic and linguistic information. The finding that the testing parameters may influence the top-down and bottom-up processing for TD should be considered when comparing data across studies or when planning new TD experiments.
Collapse
Affiliation(s)
- Yael Zaltz
- Department of Communication Disorders, The Steyer School of Health Professions, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
5
|
Fleming JT, Winn MB. Strategic perceptual weighting of acoustic cues for word stress in listeners with cochlear implants, acoustic hearing, or simulated bimodal hearing. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:1300. [PMID: 36182279 PMCID: PMC9439712 DOI: 10.1121/10.0013890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 08/08/2022] [Accepted: 08/16/2022] [Indexed: 05/28/2023]
Abstract
Perception of word stress is an important aspect of recognizing speech, guiding the listener toward candidate words based on the perceived stress pattern. Cochlear implant (CI) signal processing is likely to disrupt some of the available cues for word stress, particularly vowel quality and pitch contour changes. In this study, we used a cue weighting paradigm to investigate differences in stress cue weighting patterns between participants listening with CIs and those with normal hearing (NH). We found that participants with CIs gave less weight to frequency-based pitch and vowel quality cues than NH listeners but compensated by upweighting vowel duration and intensity cues. Nonetheless, CI listeners' stress judgments were also significantly influenced by vowel quality and pitch, and they modulated their usage of these cues depending on the specific word pair in a manner similar to NH participants. In a series of separate online experiments with NH listeners, we simulated aspects of bimodal hearing by combining low-pass filtered speech with a vocoded signal. In these conditions, participants upweighted pitch and vowel quality cues relative to a fully vocoded control condition, suggesting that bimodal listening holds promise for restoring the stress cue weighting patterns exhibited by listeners with NH.
Collapse
Affiliation(s)
- Justin T Fleming
- Department of Speech-Language-Hearing Sciences, University of Minnesota, Minneapolis, Minnesota 55455, USA
| | - Matthew B Winn
- Department of Speech-Language-Hearing Sciences, University of Minnesota, Minneapolis, Minnesota 55455, USA
| |
Collapse
|
6
|
Koelewijn T, Gaudrain E, Tamati T, Başkent D. The effects of lexical content, acoustic and linguistic variability, and vocoding on voice cue perception. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:1620. [PMID: 34598602 DOI: 10.1121/10.0005938] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 08/02/2021] [Indexed: 06/13/2023]
Abstract
Perceptual differences in voice cues, such as fundamental frequency (F0) and vocal tract length (VTL), can facilitate speech understanding in challenging conditions. Yet, we hypothesized that in the presence of spectrotemporal signal degradations, as imposed by cochlear implants (CIs) and vocoders, acoustic cues that overlap for voice perception and phonemic categorization could be mistaken for one another, leading to a strong interaction between linguistic and indexical (talker-specific) content. Fifteen normal-hearing participants performed an odd-one-out adaptive task measuring just-noticeable differences (JNDs) in F0 and VTL. Items used were words (lexical content) or time-reversed words (no lexical content). The use of lexical content was either promoted (by using variable items across comparison intervals) or not (fixed item). Finally, stimuli were presented without or with vocoding. Results showed that JNDs for both F0 and VTL were significantly smaller (better) for non-vocoded compared with vocoded speech and for fixed compared with variable items. Lexical content (forward vs reversed) affected VTL JNDs in the variable item condition, but F0 JNDs only in the non-vocoded, fixed condition. In conclusion, lexical content had a positive top-down effect on VTL perception when acoustic and linguistic variability was present but not on F0 perception. Lexical advantage persisted in the most degraded conditions and vocoding even enhanced the effect of item variability, suggesting that linguistic content could support compensation for poor voice perception in CI users.
Collapse
Affiliation(s)
- Thomas Koelewijn
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Etienne Gaudrain
- CNRS Unité Mixte de Recherche 5292, Lyon Neuroscience Research Center, Auditory Cognition and Psychoacoustics, Institut National de la Santé et de la Recherche Médicale, UMRS 1028, Université Claude Bernard Lyon 1, Université de Lyon, Lyon, France
| | - Terrin Tamati
- Department of Otolaryngology-Head & Neck Surgery, The Ohio State University Wexner Medical Center, The Ohio State University, Columbus, Ohio, USA
| | - Deniz Başkent
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
7
|
Zaltz Y, Goldsworthy RL, Eisenberg LS, Kishon-Rabin L. Children With Normal Hearing Are Efficient Users of Fundamental Frequency and Vocal Tract Length Cues for Voice Discrimination. Ear Hear 2021; 41:182-193. [PMID: 31107364 PMCID: PMC9371943 DOI: 10.1097/aud.0000000000000743] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The ability to discriminate between talkers assists listeners in understanding speech in a multitalker environment. This ability has been shown to be influenced by sensory processing of vocal acoustic cues, such as fundamental frequency (F0) and formant frequencies that reflect the listener's vocal tract length (VTL), and by cognitive processes, such as attention and memory. It is, therefore, suggested that children who exhibit immature sensory and/or cognitive processing will demonstrate poor voice discrimination (VD) compared with young adults. Moreover, greater difficulties in VD may be associated with spectral degradation as in children with cochlear implants. OBJECTIVES The aim of this study was as follows: (1) to assess the use of F0 cues, VTL cues, and the combination of both cues for VD in normal-hearing (NH) school-age children and to compare their performance with that of NH adults; (2) to assess the influence of spectral degradation by means of vocoded speech on the use of F0 and VTL cues for VD in NH children; and (3) to assess the contribution of attention, working memory, and nonverbal reasoning to performance. DESIGN Forty-one children, 8 to 11 years of age, were tested with nonvocoded stimuli. Twenty-one of them were also tested with eight-channel, noise-vocoded stimuli. Twenty-one young adults (18 to 35 years) were tested for comparison. A three-interval, three-alternative forced-choice paradigm with an adaptive tracking procedure was used to estimate the difference limens (DLs) for VD when F0, VTL, and F0 + VTL were manipulated separately. Auditory memory, visual attention, and nonverbal reasoning were assessed for all participants. RESULTS (a) Children' F0 and VTL discrimination abilities were comparable to those of adults, suggesting that most school-age children utilize both cues effectively for VD. (b) Children's VD was associated with trail making test scores that assessed visual attention abilities and speed of processing, possibly reflecting their need to recruit cognitive resources for the task. (c) Best DLs were achieved for the combined (F0 + VTL) manipulation for both children and adults, suggesting that children at this age are already capable of integrating spectral and temporal cues. (d) Both children and adults found the VTL manipulations more beneficial for VD compared with the F0 manipulations, suggesting that formant frequencies are more reliable for identifying a specific speaker than F0. (e) Poorer DLs were achieved with the vocoded stimuli, though the children maintained similar thresholds and pattern of performance among manipulations as the adults. CONCLUSIONS The present study is the first to assess the contribution of F0, VTL, and the combined F0 + VTL to the discrimination of speakers in school-age children. The findings support the notion that many NH school-age children have effective spectral and temporal coding mechanisms that allow sufficient VD, even in the presence of spectrally degraded information. These results may challenge the notion that immature sensory processing underlies poor listening abilities in children, further implying that other processing mechanisms contribute to their difficulties to understand speech in a multitalker environment. These outcomes may also provide insight into VD processes of children under listening conditions that are similar to cochlear implant users.
Collapse
Affiliation(s)
- Yael Zaltz
- Department of Communication Disorders, The Stanley Steyer School of Health Professions, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- University of Southern California Tina and Rick Caruso Department of Otolaryngology—Head & Neck Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
| | - Raymond L. Goldsworthy
- University of Southern California Tina and Rick Caruso Department of Otolaryngology—Head & Neck Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
| | - Laurie S. Eisenberg
- University of Southern California Tina and Rick Caruso Department of Otolaryngology—Head & Neck Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
| | - Liat Kishon-Rabin
- Department of Communication Disorders, The Stanley Steyer School of Health Professions, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
8
|
Abstract
OBJECTIVE To assess the benefits of bimodal listening (i.e., addition of contralateral hearing aid) for cochlear implant (CI) users on real-world tasks involving high-talker variability speech materials, environmental sounds, and self-reported quality of life (quality of hearing) in listeners' own best-aided conditions. STUDY DESIGN Cross-sectional study between groups. SETTING Outpatient hearing clinic. PATIENTS Fifty experienced adult CI users divided into groups based on normal daily listening conditions (i.e., best-aided conditions): unilateral CI (CI), unilateral CI with contralateral HA (bimodal listening; CIHA), or bilateral CI (CICI). INTERVENTION Task-specific measures of speech recognition with low (Harvard Standard Sentences) and high (Perceptually Robust English Sentence Test Open-set corpus) talker variability, environmental sound recognition (Familiar Environmental Sounds Test-Identification), and hearing-related quality of life (Nijmegen Cochlear Implant Questionnaire). MAIN OUTCOME MEASURES Test group differences among CI, CIHA, and CICI conditions. RESULTS No group effect was observed for speech recognition with low or high-talker variability, or hearing-related quality of life. Bimodal listeners demonstrated a benefit in environmental sound recognition compared with unilateral CI listeners, with a trend of greater benefit than the bilateral CI group. There was also a visual trend for benefit on high-talker variability speech recognition. CONCLUSIONS Findings provide evidence that bimodal listeners demonstrate stronger environmental sound recognition compared with unilateral CI listeners, and support the idea that there are additional advantages to bimodal listening after implantation other than speech recognition measures, which are at risk of being lost if considering bilateral implantation.
Collapse
|
9
|
Meister H, Walger M, Lang-Roth R, Müller V. Voice fundamental frequency differences and speech recognition with noise and speech maskers in cochlear implant recipients. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:EL19. [PMID: 32007021 DOI: 10.1121/10.0000499] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Accepted: 12/11/2019] [Indexed: 06/10/2023]
Abstract
Cochlear implant (CI) recipients are limited in their perception of voice cues, such as the fundamental frequency (F0). This has important consequences for speech recognition when several talkers speak simultaneously. This examination considered the comparison of clear speech and noise-vocoded sentences as maskers. For the speech maskers it could be shown that good CI performers are able to benefit from F0 differences between target and masker. This was due to the fact that a F0 difference of 80 Hz significantly reduced target-masker confusions, an effect that was slightly more pronounced in bimodal than in bilateral users.
Collapse
Affiliation(s)
- Hartmut Meister
- Jean-Uhrmacher-Institute for Clinical ENT-Research, University of Cologne, Geibelstrasse 29-31, D-50931 Cologne, Germany
| | - Martin Walger
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, University of Cologne, Kerpenerstrasse 62, 50937 Cologne, , , ,
| | - Ruth Lang-Roth
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, University of Cologne, Kerpenerstrasse 62, 50937 Cologne, , , ,
| | - Verena Müller
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, University of Cologne, Kerpenerstrasse 62, 50937 Cologne, , , ,
| |
Collapse
|
10
|
Effects of Additional Low-Pass-Filtered Speech on Listening Effort for Noise-Band-Vocoded Speech in Quiet and in Noise. Ear Hear 2019; 40:3-17. [PMID: 29757801 PMCID: PMC6319586 DOI: 10.1097/aud.0000000000000587] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Objectives: Residual acoustic hearing in electric–acoustic stimulation (EAS) can benefit cochlear implant (CI) users in increased sound quality, speech intelligibility, and improved tolerance to noise. The goal of this study was to investigate whether the low-pass–filtered acoustic speech in simulated EAS can provide the additional benefit of reducing listening effort for the spectrotemporally degraded signal of noise-band–vocoded speech. Design: Listening effort was investigated using a dual-task paradigm as a behavioral measure, and the NASA Task Load indeX as a subjective self-report measure. The primary task of the dual-task paradigm was identification of sentences presented in three experiments at three fixed intelligibility levels: at near-ceiling, 50%, and 79% intelligibility, achieved by manipulating the presence and level of speech-shaped noise in the background. Listening effort for the primary intelligibility task was reflected in the performance on the secondary, visual response time task. Experimental speech processing conditions included monaural or binaural vocoder, with added low-pass–filtered speech (to simulate EAS) or without (to simulate CI). Results: In Experiment 1, in quiet with intelligibility near-ceiling, additional low-pass–filtered speech reduced listening effort compared with binaural vocoder, in line with our expectations, although not compared with monaural vocoder. In Experiments 2 and 3, for speech in noise, added low-pass–filtered speech allowed the desired intelligibility levels to be reached at less favorable speech-to-noise ratios, as expected. It is interesting that this came without the cost of increased listening effort usually associated with poor speech-to-noise ratios; at 50% intelligibility, even a reduction in listening effort on top of the increased tolerance to noise was observed. The NASA Task Load indeX did not capture these differences. Conclusions: The dual-task results provide partial evidence for a potential decrease in listening effort as a result of adding low-frequency acoustic speech to noise-band–vocoded speech. Whether these findings translate to CI users with residual acoustic hearing will need to be addressed in future research because the quality and frequency range of low-frequency acoustic sound available to listeners with hearing loss may differ from our idealized simulations, and additional factors, such as advanced age and varying etiology, may also play a role.
Collapse
|
11
|
El Boghdady N, Gaudrain E, Başkent D. Does good perception of vocal characteristics relate to better speech-on-speech intelligibility for cochlear implant users? THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:417. [PMID: 30710943 DOI: 10.1121/1.5087693] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Accepted: 12/21/2018] [Indexed: 06/09/2023]
Abstract
Differences in voice pitch (F0) and vocal tract length (VTL) improve intelligibility of speech masked by a background talker (speech-on-speech; SoS) for normal-hearing (NH) listeners. Cochlear implant (CI) users, who are less sensitive to these two voice cues compared to NH listeners, experience difficulties in SoS perception. Three research questions were addressed: (1) whether increasing the F0 and VTL difference (ΔF0; ΔVTL) between two competing talkers benefits CI users in SoS intelligibility and comprehension, (2) whether this benefit is related to their F0 and VTL sensitivity, and (3) whether their overall SoS intelligibility and comprehension are related to their F0 and VTL sensitivity. Results showed: (1) CI users did not benefit in SoS perception from increasing ΔF0 and ΔVTL; increasing ΔVTL had a slightly detrimental effect on SoS intelligibility and comprehension. Results also showed: (2) the effect from increasing ΔF0 on SoS intelligibility was correlated with F0 sensitivity, while the effect from increasing ΔVTL on SoS comprehension was correlated with VTL sensitivity. Finally, (3) the sensitivity to both F0 and VTL, and not only one of them, was found to be correlated with overall SoS performance, elucidating important aspects of voice perception that should be optimized through future coding strategies.
Collapse
Affiliation(s)
- Nawal El Boghdady
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Etienne Gaudrain
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Deniz Başkent
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|