1
|
de la Torre A, Sanchez I, Alvarez IM, Segura JC, Valderrama JT, Muller N, Vargas JL. Multi-response deconvolution of auditory evoked potentials in a reduced representation space. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:3639-3653. [PMID: 38836771 DOI: 10.1121/10.0026228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 05/16/2024] [Indexed: 06/06/2024]
Abstract
The estimation of auditory evoked potentials requires deconvolution when the duration of the responses to be recovered exceeds the inter-stimulus interval. Based on least squares deconvolution, in this article we extend the procedure to the case of a multi-response convolutional model, that is, a model in which different categories of stimulus are expected to evoke different responses. The computational cost of the multi-response deconvolution significantly increases with the number of responses to be deconvolved, which restricts its applicability in practical situations. In order to alleviate this restriction, we propose to perform the multi-response deconvolution in a reduced representation space associated with a latency-dependent filtering of auditory responses, which provides a significant dimensionality reduction. We demonstrate the practical viability of the multi-response deconvolution with auditory responses evoked by clicks presented at different levels and categorized according to their stimulation level. The multi-response deconvolution applied in a reduced representation space provides the least squares estimation of the responses with a reasonable computational load. matlab/Octave code implementing the proposed procedure is included as supplementary material.
Collapse
Affiliation(s)
- Angel de la Torre
- Department of Signal Theory, Telematics and Communications, University of Granada, Granada, Spain
- Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, Granada, Spain
| | - Inmaculada Sanchez
- Department of Signal Theory, Telematics and Communications, University of Granada, Granada, Spain
- AVVALE España S.L., Madrid, Spain
| | - Isaac M Alvarez
- Department of Signal Theory, Telematics and Communications, University of Granada, Granada, Spain
- Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, Granada, Spain
| | - Jose C Segura
- Department of Signal Theory, Telematics and Communications, University of Granada, Granada, Spain
- Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, Granada, Spain
| | - Joaquin T Valderrama
- Department of Signal Theory, Telematics and Communications, University of Granada, Granada, Spain
- Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, Granada, Spain
- Department of Linguistics, Macquarie University, Sydney, Australia
| | - Nicolas Muller
- ENT Service, Hospital Universitario Clinico San Cecilio, Servicio Andaluz de Salud, Granada, Spain
| | - Jose L Vargas
- ENT Service, Hospital Universitario Clinico San Cecilio, Servicio Andaluz de Salud, Granada, Spain
| |
Collapse
|
2
|
de la Torre A, Valderrama JT, Segura JC, Alvarez IM, Garcia-Miranda J. Subspace-constrained deconvolution of auditory evoked potentials. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:3745. [PMID: 35778185 DOI: 10.1121/10.0011423] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Accepted: 05/07/2022] [Indexed: 06/15/2023]
Abstract
Auditory evoked potentials can be estimated by synchronous averaging when the responses to the individual stimuli are not overlapped. However, when the response duration exceeds the inter-stimulus interval, a deconvolution procedure is necessary to obtain the transient response. The iterative randomized stimulation and averaging and the equivalent randomized stimulation with least squares deconvolution have been proven to be flexible and efficient methods for deconvolving the evoked potentials, with minimum restrictions in the design of stimulation sequences. Recently, a latency-dependent filtering and down-sampling (LDFDS) methodology was proposed for optimal filtering and dimensionality reduction, which is particularly useful when the evoked potentials involve the complete auditory pathway response (i.e., from the cochlea to the auditory cortex). In this case, the number of samples required to accurately represent the evoked potentials can be reduced from several thousand (with conventional sampling) to around 120. In this article, we propose to perform the deconvolution in the reduced representation space defined by LDFDS and present the mathematical foundation of the subspace-constrained deconvolution. Under the assumption that the evoked response is appropriately represented in the reduced representation space, the proposed deconvolution provides an optimal least squares estimation of the evoked response. Additionally, the dimensionality reduction provides a substantial reduction of the computational cost associated with the deconvolution. matlab/Octave code implementing the proposed procedures is included as supplementary material.
Collapse
Affiliation(s)
- Angel de la Torre
- Department of Signal Theory, Telematics, and Communications, University of Granada, Granada, Spain
| | | | - Jose C Segura
- Department of Signal Theory, Telematics, and Communications, University of Granada, Granada, Spain
| | - Isaac M Alvarez
- Department of Signal Theory, Telematics, and Communications, University of Granada, Granada, Spain
| | | |
Collapse
|
3
|
Smith AB, Madsen PT, Johnson M, Tyack P, Wahlberg M. Toothed whale auditory brainstem responses measured with a non-invasive, on-animal tag. JASA EXPRESS LETTERS 2021; 1:091201. [PMID: 36154211 DOI: 10.1121/10.0006454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Empirical measurements of odontocete hearing are limited to captive individuals, constituting a fraction of species across the suborder. Data from more species could be available if such measurements were collected from unrestrained animals in the wild. This study investigated whether electrophysiological hearing data could be recorded from a trained harbor porpoise (Phocoena phocoena) using a non-invasive, animal-attached tag. The results demonstrate that auditory brainstem responses to external and self-generated stimuli can be measured from a stationary odontocete using an animal-attached recorder. With additional development, tag-based electrophysiological platforms may facilitate the collection of hearing data from freely swimming odontocetes in the wild.
Collapse
Affiliation(s)
- Adam B Smith
- Marine Research Centre, University of Southern Denmark, 5300 Kerteminde, Denmark
| | - Peter T Madsen
- Zoophysiology, Department of Biology, Aarhus University, 8000 Aarhus C, Denmark
| | - Mark Johnson
- Aarhus Institute of Advanced Studies, Aarhus University, 8000 Aarhus C, Denmark
| | - Peter Tyack
- Scottish Oceans Institute, School of Biology, University of St Andrews, KY16 8LB St. Andrews, United Kingdom , , , ,
| | - Magnus Wahlberg
- Marine Research Centre, University of Southern Denmark, 5300 Kerteminde, Denmark
| |
Collapse
|
4
|
Schalles MD, Mulsow J, Houser DS, Finneran JJ, Tyack PL, Shinn-Cunningham B. Auditory oddball responses in Tursiops truncatus. JASA EXPRESS LETTERS 2021; 1:081202. [PMID: 36154254 DOI: 10.1121/10.0005991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Two previous studies suggest that bottlenose dolphins exhibit an "oddball" auditory evoked potential (AEP) to stimulus trains where one of two stimuli has a low probability of occurrence relative to another. However, they reported oddball AEPs at widely different latency ranges (50 vs 500 ms). The present work revisited this experiment in a single dolphin to report the AEPs in response to two tones each assigned probabilities of 0.2, 0.8, and 1 across sessions. The AEP was further isolated from background EEG using independent component analysis, and showed condition effects in the 40-60 ms latency range.
Collapse
Affiliation(s)
- Matt D Schalles
- Neuroscience Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213, USA
| | - Jason Mulsow
- National Marine Mammal Foundation, San Diego, California 92106, USA
| | - Dorian S Houser
- National Marine Mammal Foundation, San Diego, California 92106, USA
| | - James J Finneran
- United States Navy Marine Mammal Program, Naval Information Warfare Center Pacific, San Diego, California 92152, USA
| | - Peter L Tyack
- Biology Department, Woods Hole Oceanographic Institution, Woods Hole, Massachusetts 02543, USA , , , , ,
| | | |
Collapse
|
5
|
Schalles MD, Houser DS, Finneran JJ, Tyack P, Shinn-Cunningham B, Mulsow J. Measuring auditory cortical responses in Tursiops truncatus. J Comp Physiol A Neuroethol Sens Neural Behav Physiol 2021; 207:629-640. [PMID: 34327551 PMCID: PMC8408064 DOI: 10.1007/s00359-021-01502-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 06/10/2021] [Accepted: 06/25/2021] [Indexed: 11/30/2022]
Abstract
Auditory neuroscience in dolphins has largely focused on auditory brainstem responses; however, such measures reveal little about the cognitive processes dolphins employ during echolocation and acoustic communication. The few previous studies of mid- and long-latency auditory-evoked potentials (AEPs) in dolphins report different latencies, polarities, and magnitudes. These inconsistencies may be due to any number of differences in methodology, but these studies do not make it clear which methodological differences may account for the disparities. The present study evaluates how electrode placement and pre-processing methods affect mid- and long-latency AEPs in (Tursiops truncatus). AEPs were measured when reference electrodes were placed on the skin surface over the forehead, the external auditory meatus, or the dorsal surface anterior to the dorsal fin. Data were pre-processed with or without a digital 50-Hz low-pass filter, and the use of independent component analysis to isolate signal components related to neural processes from other signals. Results suggest that a meatus reference electrode provides the highest quality AEP signals for analyses in sensor space, whereas a dorsal reference yielded nominal improvements in component space. These results provide guidance for measuring cortical AEPs in dolphins, supporting future studies of their cognitive auditory processing.
Collapse
Affiliation(s)
- Matt D Schalles
- Neuroscience Institute, Carnegie Mellon University, Pittsburgh, PA, 15213, USA. .,Biomedical Engineering, Boston University, Boston, MA, 02215, USA.
| | - Dorian S Houser
- National Marine Mammal Foundation, San Diego, CA, 92106, USA
| | - James J Finneran
- US Navy Marine Mammal Program, Naval Information Warfare Center Pacific, San Diego, CA, 92152, USA
| | - Peter Tyack
- School of Biology, University of St Andrews, St Andrews, UK
| | - Barbara Shinn-Cunningham
- Neuroscience Institute, Carnegie Mellon University, Pittsburgh, PA, 15213, USA.,Biomedical Engineering, Boston University, Boston, MA, 02215, USA
| | - Jason Mulsow
- National Marine Mammal Foundation, San Diego, CA, 92106, USA
| |
Collapse
|
6
|
Mulsow J, Finneran JJ, Houser DS, Burkard RF, Strahan MG, Jones R. The offset auditory brainstem response in bottlenose dolphins (Tursiops truncatus): Evidence for multiple underlying processes. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:3163. [PMID: 34241086 DOI: 10.1121/10.0004830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 04/12/2021] [Indexed: 06/13/2023]
Abstract
The auditory brainstem response (ABR) to stimulus onset has been extensively used to investigate dolphin hearing. The mechanisms underlying this onset response have been thoroughly studied in mammals. In contrast, the ABR evoked by sound offset has received relatively little attention. To build upon previous observations of the dolphin offset ABR, a series of experiments was conducted to (1) determine the cochlear places responsible for response generation and (2) examine differences in response morphologies when using toneburst versus noiseburst stimuli. Measurements were conducted with seven bottlenose dolphins (Tursiops truncatus) using tonebursts and spectrally "pink" broadband noisebursts, with highpass noise used to limit the cochlear regions involved in response generation. Results for normal-hearing and hearing-impaired dolphins suggest that the offset ABR contains contributions from at least two distinct responses. One type of response (across place) might arise from the activation of neural units that are shifted basally relative to stimulus frequency and shares commonalities with the onset ABR. A second type of response (within place) appears to represent a "true" offset response from afferent centers further up the ascending auditory pathway from the auditory nerve, and likely results from synchronous activity beginning at or above the cochlear nucleus.
Collapse
Affiliation(s)
- Jason Mulsow
- National Marine Mammal Foundation, 2240 Shelter Island Drive #200, San Diego, California 92106, USA
| | - James J Finneran
- U.S. Navy Marine Mammal Program, Naval Information Warfare Center Pacific Code 56710, 53560 Hull Street, San Diego, California 92152, USA
| | - Dorian S Houser
- National Marine Mammal Foundation, 2240 Shelter Island Drive #200, San Diego, California 92106, USA
| | - Robert F Burkard
- Department of Rehabilitation Science, University at Buffalo, 626 Kimball Tower, Buffalo, New York 14214, USA
| | - Madelyn G Strahan
- National Marine Mammal Foundation, 2240 Shelter Island Drive #200, San Diego, California 92106, USA
| | - Ryan Jones
- National Marine Mammal Foundation, 2240 Shelter Island Drive #200, San Diego, California 92106, USA
| |
Collapse
|
7
|
Scanlon JEM, Jacobsen NSJ, Maack MC, Debener S. Does the electrode amplification style matter? A comparison of active and passive EEG system configurations during standing and walking. Eur J Neurosci 2020; 54:8381-8395. [PMID: 33185920 DOI: 10.1111/ejn.15037] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 09/17/2020] [Accepted: 10/26/2020] [Indexed: 11/30/2022]
Abstract
It has been stated that active-transmission electrodes should improve signal quality in mobile EEG recordings. However, few studies have directly compared active- and passive-transmission electrodes during a mobile task. In this repeated measurement study, we investigated the performance of active and passive signal transmission electrodes with the same amplifier system in their respective typical configurations, during a mobile auditory task. The task was an auditory discrimination (1,000 vs. 800 Hz; counterbalanced) oddball task using approximately 560 trials (15% targets) for each condition. Eighteen participants performed the auditory oddball task both while standing and walking in an outdoor environment. While walking, there was a significant decrease in P3 amplitude, post-trial rejection trial numbers, and signal-to-noise ratio (SNR). No significant differences were found in signal quality between the two electrode configurations. SNR and P3 amplitude were test-retest reliable between recordings. We conclude that adequate use of a passive EEG electrode system achieves signal quality equivalent to that of an active system during a mobile task.
Collapse
Affiliation(s)
- Joanna E M Scanlon
- Neuropsychology Lab, Department of Psychology, University of Oldenburg, Oldenburg, Germany
| | | | - Marike C Maack
- Neuropsychology Lab, Department of Psychology, University of Oldenburg, Oldenburg, Germany
| | - Stefan Debener
- Neuropsychology Lab, Department of Psychology, University of Oldenburg, Oldenburg, Germany.,Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany.,Center for Neurosensory Science and Systems, University of Oldenburg, Oldenburg, Germany
| |
Collapse
|
8
|
Burkard R, Finneran JJ, Mulsow J, Jones R. Offset auditory brainstem response (ABR) amplitude in bottlenose dolphins. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:1445. [PMID: 33003839 DOI: 10.1121/10.0001900] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Accepted: 08/14/2020] [Indexed: 06/11/2023]
Abstract
Although commonly recorded as onset responses, the auditory brainstem response (ABR) can also be elicited at stimulus offset. The offset ABR has not been extensively investigated in marine mammals. Three normal hearing (NH) and three hearing impaired (HI) dolphins were assessed while fully submerged in sea water. Stimulus spectrum, level, rise/fall time (RFT), and plateau duration were manipulated. Onset and offset ABR amplitude were quantified as the rms voltage 1-7 ms following stimulus onset or offset, respectively. For the same stimulus conditions, onset and offset responses were often larger for NH than HI dolphins, and offset responses were typically smaller than onset responses. For the level series, offset response amplitude typically increased with increasing stimulus level, although offset responses were not 3 dB above the noisefloor for 113-kHz tonebursts. Increasing RFT decreased onset and offset response amplitude. For the 40-kHz tonebursts, a RFT of 32 μs produced a large amplitude offset ABR in NH dolphins. Offset responses for 113-kHz tonebursts were 3 dB above the noisefloor at the shortest RFTs. Offset responses were largest for 4 ms duration stimuli (likely due to overlapping onset and offset response analysis windows), but otherwise, offset responses changed little with increasing duration.
Collapse
Affiliation(s)
- Robert Burkard
- Department of Rehabilitation Science, University at Buffalo, 626 Kimball Tower, Buffalo, New York 14260, USA
| | - James J Finneran
- U.S. Navy Marine Mammal Program, Naval Information Warfare Center Pacific Code 56710, 53560 Hull Street, San Diego, California 92152, USA
| | - Jason Mulsow
- National Marine Mammal Foundation, 2240 Shelter Island Drive #200, San Diego, California 92106, USA
| | - Ryan Jones
- National Marine Mammal Foundation, 2240 Shelter Island Drive #200, San Diego, California 92106, USA
| |
Collapse
|
9
|
Mulsow J, Finneran JJ, Accomando AW, Burkard RF. Auditory brainstem responses during aerial testing with bottlenose dolphins (Tursiops truncatus): Effects of electrode and jawphone locations. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:2525. [PMID: 32359296 DOI: 10.1121/10.0001123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 04/01/2020] [Indexed: 06/11/2023]
Abstract
Transmission of sound to dolphins during electrophysiological hearing screening is conducted out of water in certain cases (e.g., strandings). This necessitates that sound be delivered using a contact transducer either pressed against the skin or affixed to the jaw using a suction cup (i.e., "jawphones"). This study examined how bottlenose dolphin (Tursiops truncatus, n = 3) auditory brainstem responses (ABRs) varied with electrode and jawphone location during aerial testing. Stimuli were tone bursts with center frequencies of 28 to 160 kHz. Regression-based thresholds were lowest with the jawphone on the posterior and middle parts of the mandible. Thresholds based on later ABR peaks-recorded using an electrode immediately behind the blowhole-suggested more similarity between the thresholds for the anterior tip of the rostrum and the posterior/middle mandible than those based on earlier monaural waves recorded near the meatus. This was likely a result of a summation of responses from both ears as opposed to a more efficient acoustic pathway to the ear. These patterns were independent of frequency. These findings provide guidance for jawphone and electrode locations when examining dolphin hearing and when interpreting relative acoustic sensitivity of the head in similar testing situations.
Collapse
Affiliation(s)
- Jason Mulsow
- National Marine Mammal Foundation, 2240 Shelter Island Drive #200, San Diego, California 92106, USA
| | - James J Finneran
- U.S. Navy Marine Mammal Program, Naval Information Warfare Center Pacific, Code 56710, 53560 Hull Street, San Diego, California 92152, USA
| | - Alyssa W Accomando
- National Marine Mammal Foundation, 2240 Shelter Island Drive #200, San Diego, California 92106, USA
| | - Robert F Burkard
- Department of Rehabilitation Science, State University of New York, University at Buffalo, 626 Kimball Tower, Buffalo, New York 14214, USA
| |
Collapse
|
10
|
de la Torre A, Valderrama JT, Segura JC, Alvarez IM. Matrix-based formulation of the iterative randomized stimulation and averaging method for recording evoked potentials. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:4545. [PMID: 31893705 DOI: 10.1121/1.5139639] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 11/15/2019] [Indexed: 06/10/2023]
Abstract
The iterative randomized stimulation and averaging (IRSA) method was proposed for recording evoked potentials when the individual responses are overlapped. The main inconvenience of IRSA is its computational cost, associated with a large number of iterations required for recovering the evoked potentials and the computation required for each iteration [involving the whole electroencephalogram (EEG)]. This article proposes a matrix-based formulation of IRSA, which is mathematically equivalent and saves computational load (because each iteration involves just a segment with the length of the response, instead of the whole EEG). Additionally, it presents an analysis of convergence that demonstrates that IRSA converges to the least-squares (LS) deconvolution. Based on the convergence analysis, some optimizations for the IRSA algorithm are proposed. Experimental results (configured for obtaining the full-range auditory evoked potentials) show the mathematical equivalence of the different IRSA implementations and the LS-deconvolution and compare the respective computational costs of these implementations under different conditions. The proposed optimizations allow the practical use of IRSA for many clinical and research applications and provide a reduction of the computational cost, very important with respect to the conventional IRSA, and moderate with respect to the LS-deconvolution. matlab/Octave implementations of the different methods are provided as supplementary material.
Collapse
Affiliation(s)
- Angel de la Torre
- Department of Signal Theory, Telematics, and Communications, University of Granada, Granada, Spain
| | | | - Jose C Segura
- Department of Signal Theory, Telematics, and Communications, University of Granada, Granada, Spain
| | - Isaac M Alvarez
- Department of Signal Theory, Telematics, and Communications, University of Granada, Granada, Spain
| |
Collapse
|