1
|
SOGAWA KAZUYUKI, UECHI KOHEI, KIYOSUKE MAKIKO, MURATA SYOTA, KUSABA KOJI, SAEKI YUJI, HORIUCHI KAZUKI, YASUDA KAZUNARI, OKUMURA HAJIME, FUJINAGA AZUMI, MURAKAMI MASAMI. Examination of Conditions for External Quality Control in Identification of Microorganisms using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry. Biocontrol Sci 2022; 27:179-184. [DOI: 10.4265/bio.27.179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Affiliation(s)
- KAZUYUKI SOGAWA
- Department of Biochemistry, School of Life and Environmental Science, Azabu University
| | - KOHEI UECHI
- Department of Clinical Laboratory and Blood Transfusion, University Hospital of the Ryukyus
| | - MAKIKO KIYOSUKE
- Department of Clinical Chemistry and Laboratory Medicine, Kyushu University Hospital
| | - SYOTA MURATA
- Department of Clinical Laboratory, Chiba University Hospital
| | - KOJI KUSABA
- Department of Laboratory, Saga university Hospital
| | - YUJI SAEKI
- Clinical Laboratory, University of Miyazaki Hospital
| | - KAZUKI HORIUCHI
- Department of Laboratory Medicine, Shinshu University Hospital
| | | | | | | | | |
Collapse
|
2
|
Sogawa K, Kiyosuke M, Hattori K, Murata S, Watari T, Kusaba K, Saeki Y, Horiuchi K, Yasuda K, Uechi K, Okumura H, Sekiguchi S, Fujinaga A, Murakami M, Nakayama T. Examination of conditions for regular internal quality control in identification of microorganisms using MALDI-TOF MS. Biocontrol Sci 2021; 26:99-104. [PMID: 34092720 DOI: 10.4265/bio.26.99] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was approved for medical use in 2011, and is currently used as a rapid, accurate and low-cost technique for bacterial identification. Microbiological testing and internal accuracy control in Japan are mainly implemented in accordance with the standards of the Clinical and Laboratory Standards Institute (CLSI). However, few facilities perform internal accuracy control of bacterial identification by MALDI-TOF MS. Therefore, we examined the procedures for internal accuracy control of bacterial identification using MALDI-TOF MS in daily work at clinical laboratories in the seven hospitals.
Collapse
Affiliation(s)
- Kazuyuki Sogawa
- Department of Biochemistry, School of Life and Environmental Science, Azabu University
| | - Makiko Kiyosuke
- Department of Clinical Chemistry and Laboratory Medicine, Kyushu University Hospital
| | - Kanako Hattori
- Department of Clinical Chemistry and Laboratory Medicine, Kyushu University Hospital
| | - Syota Murata
- Department of Clinical Laboratory, Chiba University Hospital
| | | | - Koji Kusaba
- Department of Laboratory, Saga university Hospital
| | - Yuji Saeki
- Clinical Laboratory, University of Miyazaki Hospital
| | - Kazuki Horiuchi
- Department of Laboratory Medicine, Shinshu University Hospital
| | | | - Kohei Uechi
- Department of Clinical Laboratory and Blood Transfusion, University Hospital of the Ryukyus
| | | | | | | | | | - Tomohiro Nakayama
- Divisions of Laboratory Medicine and Companion Diagnostics, Department of Pathology and Microbiology, Nihon University School of Medicine
| |
Collapse
|
3
|
Evaluation of matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF MS) for the Identification of Group B Streptococcus. BMC Res Notes 2019; 12:85. [PMID: 30764872 PMCID: PMC6376729 DOI: 10.1186/s13104-019-4119-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 02/06/2019] [Indexed: 01/14/2023] Open
Abstract
Objective Group B Streptococcus (GBS) is a leading cause of neonatal meningitis and sepsis worldwide. Intrapartum antibiotics given to women carrying GBS are an effective means of reducing disease in the first week of life. Rapid and reliable tests are needed to accurately identify GBS from these women for timely intrapartum antibiotic administration to prevent neonatal disease. Many laboratories now use matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF MS) by direct plating or cell lysis for the identification of GBS isolates. The cell lysis step increases time to results for clinical samples and is more complex to perform. Therefore, we seek to evaluate the sensitivity and specificity of the quicker and more rapid direct plating method in identifying GBS. Results We directly compared swab isolates analysed by both direct plating and cell lysis method and demonstrated that direct plating has a sensitivity and specificity of 0.97 and 1, respectively, compared to an additional cell lysis step. We demonstrated that MALDI-TOF MS can be successfully used for batch processing by the direct plating method which saves time. These results are reassuring for laboratories worldwide who seek to identify GBS from swabs samples as quickly as possible.
Collapse
|
4
|
Improved Differentiation of Streptococcus pneumoniae and Other S. mitis Group Streptococci by MALDI Biotyper Using an Improved MALDI Biotyper Database Content and a Novel Result Interpretation Algorithm. J Clin Microbiol 2017; 55:914-922. [PMID: 28053215 DOI: 10.1128/jcm.01990-16] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Accepted: 12/27/2016] [Indexed: 12/21/2022] Open
Abstract
Reliable distinction of Streptococcus pneumoniae and viridans group streptococci is important because of the different pathogenic properties of these organisms. Differentiation between S. pneumoniae and closely related Sreptococcusmitis species group streptococci has always been challenging, even when using such modern methods as 16S rRNA gene sequencing or matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry. In this study, a novel algorithm combined with an enhanced database was evaluated for differentiation between S. pneumoniae and S. mitis species group streptococci. One hundred one clinical S. mitis species group streptococcal strains and 188 clinical S. pneumoniae strains were identified by both the standard MALDI Biotyper database alone and that combined with a novel algorithm. The database update from 4,613 strains to 5,627 strains drastically improved the differentiation of S. pneumoniae and S. mitis species group streptococci: when the new database version containing 5,627 strains was used, only one of the 101 S. mitis species group isolates was misidentified as S. pneumoniae, whereas 66 of them were misidentified as S. pneumoniae when the earlier 4,613-strain MALDI Biotyper database version was used. The updated MALDI Biotyper database combined with the novel algorithm showed even better performance, producing no misidentifications of the S. mitis species group strains as S. pneumoniae All S. pneumoniae strains were correctly identified as S. pneumoniae with both the standard MALDI Biotyper database and the standard MALDI Biotyper database combined with the novel algorithm. This new algorithm thus enables reliable differentiation between pneumococci and other S. mitis species group streptococci with the MALDI Biotyper.
Collapse
|
5
|
Vithanage NR, Yeager TR, Jadhav SR, Palombo EA, Datta N. Comparison of identification systems for psychrotrophic bacteria isolated from raw bovine milk. Int J Food Microbiol 2014; 189:26-38. [DOI: 10.1016/j.ijfoodmicro.2014.07.023] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2014] [Revised: 07/17/2014] [Accepted: 07/20/2014] [Indexed: 10/25/2022]
|
6
|
Verroken A, Defourny L, Lechgar L, Magnette A, Delmée M, Glupczynski Y. Reducing time to identification of positive blood cultures with MALDI-TOF MS analysis after a 5-h subculture. Eur J Clin Microbiol Infect Dis 2014; 34:405-13. [DOI: 10.1007/s10096-014-2242-4] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Accepted: 08/31/2014] [Indexed: 10/24/2022]
|
7
|
Evaluation of two matrix-assisted laser desorption ionization–time of flight mass spectrometry systems for identification of viridans group streptococci. Eur J Clin Microbiol Infect Dis 2013; 33:779-88. [DOI: 10.1007/s10096-013-2012-8] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2013] [Accepted: 10/23/2013] [Indexed: 10/26/2022]
|
8
|
Current status of matrix-assisted laser desorption ionisation-time of flight mass spectrometry in the clinical microbiology laboratory. Pathology 2013; 45:4-17. [DOI: 10.1097/pat.0b013e32835be408] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Martiny D, Vandenberg O. Exploitation de la spectrométrie de masse en microbiologie : une révolution. ACTA ACUST UNITED AC 2012. [DOI: 10.1016/j.immbio.2012.04.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
10
|
Martiny D, Dediste A, Vandenberg O. Comparison of an in-house method and the commercial Sepsityper™ kit for bacterial identification directly from positive blood culture broths by matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry. Eur J Clin Microbiol Infect Dis 2012; 31:2269-81. [PMID: 22367290 DOI: 10.1007/s10096-012-1566-1] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2011] [Accepted: 01/21/2012] [Indexed: 10/28/2022]
Abstract
The identification of bacteria directly from positive blood cultures using matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry (MALDI-TOF MS) is a new challenge to microbiologists. However, the protocols previously described are often difficult to implement in routine and comparisons are not always possible due to the variability of interpretative criteria. This study evaluated the analytical and practical performances of an in-house (IH) method, adapted from previous protocols, and the Sepsityper™ kit (Bruker Daltonics, Bremen, Germany). Positive blood cultures from 63 different patients were prospectively evaluated by both methods. To enhance the sensitivity of these methods, lowered cut-offs were assessed and validated on 66 additional samples. The IH method produced 86.4% and 73.7% correct genus and species identifications, respectively, when using the lowered cut-offs of 1.4 and 1.6 for correct genus and species identifications. The Sepsityper™ kit showed similar results (78.0% and 68.4% correct genus and species identification, respectively). However, the IH method is ten-fold less expensive than the commercial option (0.72 vs. 7.45 <euro>/analysis) and its turnaround time is approximately 20 min versus the nearly 40 min required for the Sepsityper™ kit, which includes an extraction step. Finally, the IH method was introduced twice-daily in our routine practice.
Collapse
Affiliation(s)
- D Martiny
- Department of Microbiology, Saint-Pierre University Hospital and Jules Bordet Institute, rue Haute 322, 1000, Brussels, Belgium.
| | | | | |
Collapse
|
11
|
Direct analysis and identification of pathogenic Lichtheimia species by matrix-assisted laser desorption ionization-time of flight analyzer-mediated mass spectrometry. J Clin Microbiol 2011; 50:419-27. [PMID: 22135259 DOI: 10.1128/jcm.01070-11] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Zygomycetes of the order Mucorales can cause life-threatening infections in humans. These mucormycoses are emerging and associated with a rapid tissue destruction and high mortality. The resistance of Mucorales to antimycotic substances varies between and within clinically important genera such as Mucor, Rhizopus, and Lichtheimia. Thus, an accurate diagnosis before onset of antimycotic therapy is recommended. Matrix-assisted laser desorption ionization (MALDI)-time of flight (TOF) mass spectrometry (MS) is a potentially powerful tool to rapidly identify infectious agents on the species level. We investigated the potential of MALDI-TOF MS to differentiate Lichtheimia species, one of the most important agents of mucormycoses. Using the Bruker Daltonics FlexAnalysis (version 3.0) software package, a spectral database library with m/z ratios of 2,000 to 20,000 Da was created for 19 type and reference strains of clinically relevant Zygomycetes of the order Mucorales (12 species in 7 genera). The database was tested for accuracy by use of 34 clinical and environmental isolates of Lichtheimia comprising a total of five species. Our data demonstrate that MALDI-TOF MS can be used to clearly discriminate Lichtheimia species from other pathogenic species of the Mucorales. Furthermore, the method is suitable to discriminate species within the genus. The reliability and robustness of the MALDI-TOF-based identification are evidenced by high score values (above 2.3) for the designation to a certain species and by moderate score values (below 2.0) for the discrimination between clinically relevant (Lichtheimia corymbifera, L. ramosa, and L. ornata) and irrelevant (L. hyalospora and L. sphaerocystis) species. In total, all 34 strains were unequivocally identified by MALDI-TOF MS with score values of >1.8 down to the generic level, 32 out of 34 of the Lichtheimia isolates (except CNM-CM 5399 and FSU 10566) were identified accurately with score values of >2 (probable species identification), and 25 of 34 isolates were identified to the species level with score values of >2.3 (highly probable species identification). The MALDI-TOF MS-based method reported here was found to be reproducible and accurate, with low consumable costs and minimal preparation time.
Collapse
|
12
|
Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of nocardia species. J Clin Microbiol 2010; 48:4015-21. [PMID: 20861335 DOI: 10.1128/jcm.01234-10] [Citation(s) in RCA: 105] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The identification of Nocardia species, usually based on biochemical tests together with phenotypic in vitro susceptibility and resistance patterns, is a difficult and lengthy process owing to the slow growth and limited reactivity of these bacteria. In this study, a panel of 153 clinical and reference strains of Nocardia spp., altogether representing 19 different species, were characterized by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). As reference methods for species identification, full-length 16S rRNA gene sequencing and phenotypical biochemical and enzymatic tests were used. In a first step, a complementary homemade reference database was established by the analysis of 110 Nocardia isolates (pretreated with 30 min of boiling and extraction) in the MALDI BioTyper software according to the manufacturer's recommendations for microflex measurement (Bruker Daltonik GmbH, Leipzig, Germany), generating a dendrogram with species-specific cluster patterns. In a second step, the MALDI BioTyper database and the generated database were challenged with 43 blind-coded clinical isolates of Nocardia spp. Following addition of the homemade database in the BioTyper software, MALDI-TOF MS provided reliable identification to the species level for five species of which more than a single isolate was analyzed. Correct identification was achieved for 38 of the 43 isolates (88%), including 34 strains identified to the species level and 4 strains identified to the genus level according to the manufacturer's log score specifications. These data suggest that MALDI-TOF MS has potential for use as a rapid (<1 h) and reliable method for the identification of Nocardia species without any substantial costs for consumables.
Collapse
|