LeBar WD, Resek CM, Crist AE, Sautter RL. Comparison of a rapid latex agglutination assay and a fluorescent-antibody technique for the detection of herpes simplex antibody.
Diagn Microbiol Infect Dis 1988;
11:21-4. [PMID:
3064956 DOI:
10.1016/0732-8893(88)90069-7]
[Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
A total of 202 serum specimens was tested for the presence of herpes simplex virus antibody using a premarket latex agglutination kit (Wampole) and an indirect fluorescent antibody (IFA) technique (electronucleonics). Discrepant results between the two assays were resolved using an Enzyme-linked immunosorbent assay (ELISA) procedure. The overall sensitivity of the latex was 99.2% with a specificity of 98.5%. The latex agglutination test evaluated is a viable alternative to indirect immunofluorescence for the detection of herpes simplex virus antibody in serum samples.