1
|
Li J, Jin X, Liu S, Lin T, Zhang C, Chen Q, Ma Y. A Ratiometric Fluorescent Probe Based on Carbon Dots and Quantum Dots for Glucose Detection. J Fluoresc 2025:10.1007/s10895-025-04228-8. [PMID: 40100314 DOI: 10.1007/s10895-025-04228-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2025] [Accepted: 02/24/2025] [Indexed: 03/20/2025]
Abstract
Glucose is a critical energy source for human cells, and maintaining stable glucose levels is essential for normal physiological functions. Abnormal glucose levels can lead to health issues such as diabetes, obesity, and hypoglycemia, highlighting the need for precise and rapid glucose detection methods for clinical diagnostics and health management. In this study, a novel ratiometric fluorescent probe was constructed for glucose detection. Using glucose oxidase (GOx) and horseradish peroxidase (HRP) as enzymatic mediators, the probe employs orange-emitting carbon dots (oCDs) as the detection signal and red-emitting quantum dots (rQDs) as the reference signal. Glucose is oxidized by GOx to produce hydrogen peroxide (H2O2), which subsequently generates hydroxyl radicals (·OH) under HRP catalysis. The ·OH interacts electrostatically with oCDs, forming non-fluorescent complexes and quenching the oCDs fluorescence. Glucose concentration is quantified by monitoring the fluorescence intensity ratio (I590/I715) between oCDs and rQDs. The probe has a limit of detection (LOD) of 0.47 µM and a limit of quantification (LOQ) of 1.58 µM. After methodological validation, it has been successfully applied to the detection of glucose in human serum. This study provides a solid basis for accurate glucose monitoring and holds potential for the early diagnosis and treatment of metabolic diseases such as diabetes.
Collapse
Affiliation(s)
- Jing Li
- School of Pharmacy, Xuzhou Medical University, Xuzhou, Jiangsu, 22004, China
| | - Xiaojuan Jin
- School of Pharmacy, Xuzhou Medical University, Xuzhou, Jiangsu, 22004, China
| | - Sunan Liu
- School of Pharmacy, Xuzhou Medical University, Xuzhou, Jiangsu, 22004, China
| | - Tongze Lin
- School of Pharmacy, Xuzhou Medical University, Xuzhou, Jiangsu, 22004, China
| | - Cheng Zhang
- Xuzhou Hospital of Traditional Chinese Medicine Affiliated to Nanjing University of Chinese Medicine, Xuzhou, Jiangsu, 221000, China.
| | - Qiutong Chen
- Department of Pharmacy, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, 221006, China.
| | - Yunsu Ma
- School of Pharmacy, Xuzhou Medical University, Xuzhou, Jiangsu, 22004, China.
| |
Collapse
|
2
|
Tian M, Zhao L, Wang Y, Liu G, Zhang P. Determination of Glucose by the Catalysis of Luminol Chemiluminescence Using One-Step Synthesized Platinum/Silver Nanoparticles as a Peroxidase Mimetic. ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2096626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Miaomiao Tian
- Institute of Chemical and Industrial Bioengineering, Jilin Engineering Normal University, Changchun, Jilin Province, China
| | - Liping Zhao
- Institute of Chemical and Industrial Bioengineering, Jilin Engineering Normal University, Changchun, Jilin Province, China
| | - Ya Wang
- Institute of Chemical and Industrial Bioengineering, Jilin Engineering Normal University, Changchun, Jilin Province, China
| | - Gang Liu
- Institute of Chemical and Industrial Bioengineering, Jilin Engineering Normal University, Changchun, Jilin Province, China
| | - Peng Zhang
- Institute of Chemical and Industrial Bioengineering, Jilin Engineering Normal University, Changchun, Jilin Province, China
| |
Collapse
|