1
|
Ely AL, Pantanelli SM, Borkhetaria RK, Barbieri CA, McQuillan PM. Nd:YAG laser posterior capsulotomy performed under general anesthesia in the sitting position: a novel approach. Digit J Ophthalmol 2023; 29:36-39. [PMID: 37727471 PMCID: PMC10506613 DOI: 10.5693/djo.02.2023.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
We present a novel approach for performing an Nd:YAG laser posterior capsulotomy under general anesthesia with the patent in a seated position. We illustrate this approach in 2 cases, a young child and an adult patient with developmental delay. This technique may facilitate YAG capsulotomy in patients who cannot sit for the procedure.
Collapse
Affiliation(s)
- Amanda L. Ely
- Department of Ophthalmology, Pennsylvania State College of Medicine, Hershey, Pennsylvania
| | - Seth M. Pantanelli
- Department of Ophthalmology, Pennsylvania State College of Medicine, Hershey, Pennsylvania
| | | | - Carolyn A. Barbieri
- Department of Anesthesiology, Pennsylvania State College of Medicine, Hershey, Pennsylvania
| | - Patrick M. McQuillan
- Department of Anesthesiology, Pennsylvania State College of Medicine, Hershey, Pennsylvania
| |
Collapse
|
2
|
Kitaguchi-Iwakiri Y, Kamoi K, Takase H, Okubo Y, Ohno-Matsui K. Long-term incidence of posterior capsular opacification in patients with non-infectious uveitis. Sci Rep 2022; 12:4296. [PMID: 35277585 PMCID: PMC8917155 DOI: 10.1038/s41598-022-08325-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 03/07/2022] [Indexed: 11/24/2022] Open
Abstract
Little is known about the long-term incidence of posterior capsule opacification (PCO) after cataract surgery in patients with uveitis. This retrospective study included 211 eyes of 146 patients with non-infectious uveitis who underwent cataract surgery and implantation of an Acrysof SN60WF (Surface: plasma-treated, Optic and Haptic: hydrophobic acrylic), iSert XY-1 (Surface: UV-ozone-treated, Optic and Haptic: hydrophobic acrylic), or iSert 251/255 (Surface: UV-ozone-treated, Optics: hydrophobic acrylic, Haptic: polymethyl methacrylate). The cumulative incidences of PCO and subsequent yttrium–aluminum-garnet (Nd:YAG) capsulotomy over the 5-year follow-up were analyzed, and patients who were implanted with different intraocular lenses (IOLs) were compared. Mixed-effects Cox proportional hazard models showed that, compared with the Acrysof group, the iSert XY-1 group had higher risks of PCO (adjusted HR, 7.26; 95% CI, 1.82–28.8) and Nd:YAG capsulotomy (adjusted HR, 6.50; 95% CI, 1.55–27.2). Similar results were obtained when the Acrysof group was compared with the iSert 251/255 group for PCO (adjusted HR, 8.22; 95% CI, 2.35–28.7) and Nd:YAG capsulotomy (adjusted HR, 8.26; 1.90–36.0). These data suggest that a plasma-treated surface, hydrophobic acrylic optic and hydrophobic acrylic haptic, of the IOL could enhance biocompatibility even under inflammatory conditions, thus suppressing PCO development.
Collapse
Affiliation(s)
- Yuki Kitaguchi-Iwakiri
- Department of Ophthalmology & Visual Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8519, Japan
| | - Koju Kamoi
- Department of Ophthalmology & Visual Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8519, Japan.
| | - Hiroshi Takase
- Department of Ophthalmology & Visual Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8519, Japan
| | - Yusuke Okubo
- Division of Lifecourse Epidemiology, Department of Social Medicine, National Center for Child Health and Development, Tokyo, Japan.,Department of Epidemiology, UCLA Fielding School of Public Health, Los Angeles, CA, USA
| | - Kyoko Ohno-Matsui
- Department of Ophthalmology & Visual Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8519, Japan
| |
Collapse
|
3
|
Konopińska J, Młynarczyk M, Dmuchowska DA, Obuchowska I. Posterior Capsule Opacification: A Review of Experimental Studies. J Clin Med 2021; 10:jcm10132847. [PMID: 34199147 PMCID: PMC8269180 DOI: 10.3390/jcm10132847] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 06/13/2021] [Accepted: 06/24/2021] [Indexed: 11/16/2022] Open
Abstract
Posterior capsule opacification (PCO) is the most common complication of cataract surgery. It causes a gradual deterioration of visual acuity, which would otherwise improve after a successful procedure. Despite recent advances in ophthalmology, this complication has not been eradicated, and the incidence of PCO can be as high as 10%. This article reviews the literature concerning the pathomechanism of PCO and examines the biochemical pathways involved in its formation and methods to prevent this complication. We also review the reported tests performed in cell cultures under laboratory conditions and in experimental animal models and in ex vivo human lens capsules. Finally, we describe research involving human eyes in the clinical setting and pharmacological methods that may reduce the frequency of PCO. Due to the multifactorial etiology of PCO, in vitro studies make it possible to assess the factors contributing to its complications and search for new therapeutic targets. Not all pathways involved in cell proliferation, migration, and contraction of the lens capsule are reproducible in laboratory conditions; moreover, PCO in humans and laboratory animals may be additionally stimulated by various degrees of postoperative reactions depending on the course of surgery. Therefore, further studies are necessary.
Collapse
|
4
|
Shoughy SS, Jaroudi MO, Tabbara KF. Incidence of posterior capsule opacification following phacoemulsification in patients with uveitis. Saudi J Ophthalmol 2021; 34:182-185. [PMID: 34085010 PMCID: PMC8081085 DOI: 10.4103/1319-4534.310414] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 07/07/2020] [Accepted: 07/25/2020] [Indexed: 12/03/2022] Open
Abstract
PURPOSE: The purpose of this study was to evaluate the incidence of posterior capsule opacification (PCO) in patients with inactive uveitis who underwent phacoemulsification with acrylic hydrophobic intraocular lens. METHODS: Thus was a retrospective review of 25 consecutive patients (31 eyes) with uveitis who underwent phacoemulsification. A group of 100 patients (140 eyes) without uveitis served as historical controls. RESULTS: In patients with uveitis, PCO occurred in 11 eyes (35.5%), 6 (19%) of which were visually significant and required treatment with neodymium-doped yttrium aluminum garnet (Nd: YAG) laser. In the control group, PCO developed in 17 (12%) eyes which required treatment with Nd: YAG laser. The incidence of PCO was significantly higher in uveitis patients compared to the control group (P = 0.001), but the incidence of visually significant PCO requiring laser capsulotomy was not statistically significant (P = 0.3). CONCLUSION: The incidence of PCO in patients with uveitis was significantly higher than those without uveitis, but the need for Nd: YAG laser capsulotomy for visually significant PCO was not statistically significant.
Collapse
Affiliation(s)
- Samir S Shoughy
- The Eye Center and the Eye Foundation for Research in Ophthalmology, King Saud University, Riyadh, Saudi Arabia
| | - Mahmoud O Jaroudi
- The Eye Center and the Eye Foundation for Research in Ophthalmology, King Saud University, Riyadh, Saudi Arabia
| | - Khalid F Tabbara
- The Eye Center and the Eye Foundation for Research in Ophthalmology, King Saud University, Riyadh, Saudi Arabia.,Department of Ophthalmology, College of Medicine, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
5
|
Measurement of Force Required for Anterior Displacement of Intraocular Lenses and Its Defining Parameters. MATERIALS 2020; 13:ma13204593. [PMID: 33076490 PMCID: PMC7602541 DOI: 10.3390/ma13204593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 10/07/2020] [Accepted: 10/13/2020] [Indexed: 12/25/2022]
Abstract
Intraocular stability during or after cataract and glaucoma filtration surgeries and vitreous surgery with a gas/silicone oil tamponade might differ among intraocular lenses (IOLs). We used six different one-piece IOL models and measured the force that displaced the IOLs from the vitreous cavity to anterior chamber as a measure of stability against the pressure gradient between the anterior and posterior IOL surfaces. We measured IOL hardness, haptics junction area, and posterior IOL bulge to identify what determines the IOL displacement force. The KOWA YP2.2 IOL (1.231 mN) required significantly greater force than the HOYA XY1 (0.416 mN, p = 0.0004), HOYA 255 (0.409 mN, p = 0.0003), Alcon SN60WF (0.507 mN, p = 0.0010), and Nidek NS60YG (0.778 mN, p = 0.0186) IOLs; J&J ZCB00V IOL (1.029 mN) required greater force than the HOYA XY1 (p = 0.0032) and HOYA 255 (p = 0.0029) IOLs; the Nidek NS60YG IOL required greater force than the HOYA 255 (p = 0.0468) IOL. The haptics junction area was correlated positively with the IOL displacement force (r = 0.8536, p = 0.0306); the correlations of the other parameters were non-significant. After adjusting for any confounding effects, the haptics junction area was correlated significantly with the IOL displacement force (p = 0.0394); the IOL hardness (p = 0.0573) and posterior IOL bulge (p = 0.0938) were not. The forces that displace IOLs anteriorly differed among one-piece soft-acrylic IOLs, and the optics/haptics junction area was the major force determinant.
Collapse
|
6
|
Fișuș AD, Findl O. Capsular fibrosis: a review of prevention methods and management. Eye (Lond) 2019; 34:256-262. [PMID: 31804626 DOI: 10.1038/s41433-019-0723-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 10/27/2019] [Accepted: 11/13/2019] [Indexed: 02/02/2023] Open
Abstract
Opacification of the posterior capsule caused by residual lens epithelial cells (LEC) is still the most frequent long-term complication of cataract surgery. Beside the opacification of the visual axis with posterior capsule opacification (PCO), resulting in a decrease in visual function, fibrotic changes may also have a mechanical effect on intraocular lens (IOL) position such as axial shift, decentration, tilt and capsule striae. In this article, two types of capsular fibrosis are explored, on the one hand the anterior capsule fibrosis and on the other hand PCO. Results from clinical trials concerning their causes, natural course, incidence, influencing factors and possible methods of prophylaxis are presented.
Collapse
Affiliation(s)
- Andreea D Fișuș
- Department of Ophthamology, Vienna Institute for Research in Ocular Surgery - Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.,George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu-Mureș, Târgu-Mureș, România
| | - Oliver Findl
- Department of Ophthamology, Vienna Institute for Research in Ocular Surgery - Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.
| |
Collapse
|
7
|
INTRAOPERATIVE AND POSTOPERATIVE COMPLICATIONS IN PHACOVITRECTOMY FOR EPIRETINAL MEMBRANE AND MACULAR HOLE. Retina 2018; 38:1865-1872. [DOI: 10.1097/iae.0000000000002034] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
8
|
Von Tress M, Marotta JS, Lane SS, Sarangapani R. A meta-analysis of Nd:YAG capsulotomy rates for two hydrophobic intraocular lens materials. Clin Ophthalmol 2018; 12:1125-1136. [PMID: 29950808 PMCID: PMC6018849 DOI: 10.2147/opth.s161380] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose The purpose of this study is to estimate and compare neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomy rates for AcrySof ® and Clareon® intraocular lens (IOL) materials using historical data from the medical literature and Alcon-sponsored clinical studies. Methods Clinical trials that involved the implantation of AcrySof or Clareon monofocal IOLs in subjects with cataract or presbyopia were extracted from the literature and a company repository of clinical studies. The study duration, number of eyes, and cumulative percent of Nd:YAGs for posterior capsule opacification were extracted. Bayesian random effects meta-analyses were conducted to estimate and compare outcomes for the 2 different IOL materials. Results A Bayesian random effects, meta-analysis was performed that combined a literature review of published AcrySof Nd:YAG posterior capsulotomy rates and Nd:YAG rates observed in Alcon-sponsored clinical studies of AcrySof and Clareon. Sixteen Alcon studies contained Nd:YAG data suitable for meta-analysis. Three of these Alcon studies contained results for the Clareon material (2 one-year studies, and 1 three-year study). The literature review included 50 papers from 1998 to 2015. In combination, 30,891 eyes were available for analysis and 2040 Nd:YAG procedures were reported in studies with a follow-up duration ranging in length from 4 months to 10 years. The overall probability of performing a Nd:YAG capsulotomy within a year of implant for AcrySof was 1.44% (1.11% to 1.83%) and 0.62% (0.21% to 1.38%) for Clareon. There was small improvement in the probability of Nd:YAG within a year of implant for Clareon lenses of about 0.82% with a 95% credible interval of (0.07% to 1.36%) at 1 year. Results were similar for incidence rates per 100 surgeries in a year: 0.62 (0.21 to 1.40) for Clareon, 1.46 (1.12 to 1.87) for AcrySof, and the difference was 0.84 (0.07 to 1.39) favoring Clareon. At 3 years, the overall probability of performing a Nd:YAG capsulotomy for AcrySof was 4.19% (3.24% to 5.30%) compared with only 1.82% (0.63% to 4.02%) for Clareon. Conclusion A meta-analysis of Clareon multi-piece and single-piece clinical data predicts that the cumulative Clareon Nd:YAG probability will be ≤ AcrySof by 2.37% (0.18% to 3.91%) at 3 years. The results indicate that Clareon is likely to perform as well as, and possibly better than, AcrySof in terms of Nd:YAG capsulotomy rates.
Collapse
Affiliation(s)
| | | | - Stephen S Lane
- Global Clinical Strategy, Alcon Laboratories, Fort Worth, TX, USA
| | | |
Collapse
|
9
|
Biomaterial Influence on Intraocular Lens Performance: An Overview. J Ophthalmol 2018; 2018:2687385. [PMID: 29736282 PMCID: PMC5874989 DOI: 10.1155/2018/2687385] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Revised: 12/08/2017] [Accepted: 01/02/2018] [Indexed: 11/18/2022] Open
Abstract
There is strong evidence that the IOL material is the factor having the greatest impact on posterior capsule opacification (PCO), anterior capsule opacification (ACO) development, and glistening formation after cataract surgery, even though there are other IOL features—such as haptic material and design and edge and optic design—that also have some influence. We reviewed the published literature describing the adverse events that are mainly related to the intraocular lens (IOL) material, such as PCO, ACO, and the subsequent capsule contraction, as well as glistening formation. The adverse events presented in this overview are the most common ones in clinical practice, and therefore, they are generally included in the clinical protocols for IOL evaluation.
Collapse
|
10
|
Nanu RV, Ungureanu E, Instrate SL, Vrapciu A, Cozubas R, Carstocea L, Voinea LM, Ciuluvica R. An overview of the influence and design of biomaterial of the intraocular implant of the posterior capsule opacification. Rom J Ophthalmol 2018; 62:188-193. [PMID: 30505987 PMCID: PMC6256071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Posterior capsule opacification remains till nowadays one of the most hypothetical problems concerning the cataract surgery. When it comes in preventing PCO, this complication is made in multiple ways that concern, along with the surgery steps, the choice for the biomaterial of the intraocular implant lens. The concern of influence of the type of the used material (hydro-phob/ hydro-philic), of the design of the implant (1-piece IOL = monobloc vs. 3 - piece IOL - multipiece) and with the design at the edge, they all have been considered in multiple studies. This article performs a synthesis of those studies and establishes conclusions regarding possible choices. Abbreviations: PCO = Posterior capsule opacification, IOL = intraocular lens; LEC = lens epithelial cells.
Collapse
Affiliation(s)
| | - Emil Ungureanu
- Ophthalmology Department, University Emergency Hospital; “Carol Davila”
University of Medicine and Pharmacy, Bucharest, Romania
| | - Sinziana Luminita Instrate
- Ophthalmology Department, University Emergency Hospital; “Carol Davila”
University of Medicine and Pharmacy, Bucharest, Romania
| | - Alexandra Vrapciu
- Ophthalmology Department, University Emergency Hospital; “Carol Davila”
University of Medicine and Pharmacy, Bucharest, Romania
| | - Roxana Cozubas
- ”Grigore Alexandrescu” Emergency Hospital for Children, Bucharest, Romania
| | - Laura Carstocea
- PhD Student, “Carol Davila” University of Medicine and Pharmacy, Bucharest, Romania
| | - Liliana Mary Voinea
- Ophthalmology Department, University Emergency Hospital; “Carol Davila”
University of Medicine and Pharmacy, Bucharest, Romania
| | - Radu Ciuluvica
- Anatomy Department, “Carol Davila” University of Medicine and Pharmacy, Bucharest, Romania
| |
Collapse
|
11
|
Kim SY, Chung YK, Shin HY, Lee MY, Lee YC, Kim SY. Comparison of Nd: YAG capsulotomy rate between 1-piece and 3-piece acrylic intraocular lenses: A STROBE-compliant article. Medicine (Baltimore) 2017; 96:e7444. [PMID: 28682911 PMCID: PMC5502184 DOI: 10.1097/md.0000000000007444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The aim of the study is to compare Nd:YAG capsulotomy rate between acrylic 1- and 3-piece intraocular lenses. Among 924 eyes of 762 patients who received cataract surgery, we selected the 303 patients (404 eyes) implanted with an SN60WF 1-piece intraocular lens (Alcon, Fort Worth, TX) or a YA-60BBR 3-piece intraocular lens (Hoya Co., Tokyo, Japan). For intraindividual comparison, we enrolled the 17 patients implanted with an SN60WF in 1 eye and a YA-60BBR in the contralateral eye. We compared Nd:YAG capsulotomy rate between acrylic 1- and 3-piece intraocular lenses 24 months after the operation. Of the 404 eyes in this study, Nd:YAG capsulotomy was performed in 20 of 268 eyes (7.5%) in the SN60WF 1-piece intraocular lens group and 24 of 136 eyes (17.6%) in the YA-60BBR 3-piece intraocular lens group; the difference was statistically significant (P = .002). Among the 17 patients (34 eyes) who were implanted with 2 different inraocular lenses, Nd:YAG capsulotomy was performed in only 2 eyes (12%) in the SN60WF group and 9 eyes (53%) in the YA-60BBR group; the difference was statistically significant (P = .020).The authors found a significantly greater incidence of Nd:YAG capsulotomy in eyes who received 3-piece lenses compared with those who received 1-piece lenses.
Collapse
|
12
|
Sharon Y, Livny E, Mimouni M, Weinberger D, Bahar I. Laser capsulotomy following cataract surgery: Comparing time to capsulotomy with implantation of two broadly used intraocular lenses. Indian J Ophthalmol 2017; 65:144-147. [PMID: 28345571 PMCID: PMC5381294 DOI: 10.4103/ijo.ijo_933_16] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
PURPOSE The aim of this study is to compare the length of time from uneventful cataract surgery using one of two common posterior chamber intraocular lenses (IOLs) (hydrophilic versus hydrophobic acrylic) to laser capsulotomy. MATERIALS AND METHODS Retrospective analysis of all patients who underwent neodymium: yttrium-aluminum-garnet laser capsulotomy between 2011 and 2014 following uneventful phacoemulsification surgery at a tertiary university-affiliated medical center. Medical records were reviewed for demographics, ocular comorbidities, operative details, postoperative follow-up, and findings of the precapsulotomy ophthalmologic examination. Parameters, including age, sex, laterality, visual acuity, surgeon's experience, and time from cataract surgery to capsulotomy, were compared between patients who received hydrophilic (SeeLens AF, Kibbutz Hanita, Israel) or hydrophobic (AcrySof SA60AT, Alcon Laboratories, Fort Worth, TX, USA) IOLs. RESULTS The cohort included 222 patients (255 eyes), of which, 107 were male and 115 female, of mean age 73 ± 8 years. Mean interval from cataract surgery to laser capsulotomy was 24 months (range 2-70) and was significantly shorter in patients with SeeLens (23 ± 13 months) than AcrySof IOL implantation (28 ± 13 months, P = 0.04). Lens type remained significant in multivariate analysis after including surgeon's experience and age as potential confounders (P = 0.04). CONCLUSION The hydrophilic SeeLens IOL is associated with a significantly shorter time interval from cataract surgery to laser capsulotomy than the hydrophobic AcrySof IOL.
Collapse
Affiliation(s)
- Yael Sharon
- Department of Ophthalmology, Rabin Medical Center, Petach Tikva, Israel
| | - Eitan Livny
- Department of Ophthalmology, Rabin Medical Center, Petach Tikva, Israel
| | - Michael Mimouni
- Department of Ophthalmology, Rambam Medical Center, Haifa, Israel
| | - Dov Weinberger
- Department of Ophthalmology, Rabin Medical Center, Petach Tikva; Department of Ophthalmology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Irit Bahar
- Department of Ophthalmology, Rabin Medical Center, Petach Tikva; Department of Ophthalmology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
13
|
Stepanov A, Nekolova J, Jiraskova N, Rozsival P. Long-term follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2015; 160:143-8. [PMID: 26365930 DOI: 10.5507/bp.2015.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Accepted: 07/23/2015] [Indexed: 11/23/2022] Open
Abstract
AIM To compare the degree of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods during an 8-year follow-up period using two types of software. DESIGN Prospective, randomized clinical trial. METHODS AquaLase was used in the right eye and NeoSoniX in the left eye of each patient with bilateral cataract. RESULTS Fifty patients were analyzed 1 year, 46 patients 3 years, and 37 patients 8 years after cataract surgery. Mean EPCO 2000 values were for the AquaLase group 0.324 ± 0.305 and for the NeoSoniX group 0.298 ± 0.341 (P = 0.53) 1 year after surgery, for the AquaLase group 0.582 ± 0.506 and for the NeoSoniX group 0.594 ± 0.515 (P = 0.87) 3 years after surgery, and for the AquaLase group 0.648 ± 0.567 and for the NeoSoniX group 0.673 ± 0.542 (P = 0.30) 8 years after surgery. The OSCA results were for the AquaLase group 0.7097 ± 0.3778 and for the NeoSoniX group 0.8584 ± 0.4323 (P = 0.046) 1 year after surgery, for the AquaLase group 0.9667 ± 0.736 and for the NeoSoniX group 0.9540 ± 0.5250 (P = 0.91) 3 years after surgery, and for the AquaLase group 1,035 ± 0,952 and for the NeoSoniX group 1,103 ± 0,741 (P = 0.44) 8 years after surgery. CONCLUSION There was minimal PCO difference between these 2 approaches, AquaLase and NeoSoniX. Neither AquaLase nor NeoSoniX technique was able to prevent a natural progression of PCO.
Collapse
Affiliation(s)
- Alexandr Stepanov
- Department of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Czech Republic
| | - Jana Nekolova
- Department of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Czech Republic
| | - Nada Jiraskova
- Department of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Czech Republic
| | - Pavel Rozsival
- Department of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Czech Republic
| |
Collapse
|
14
|
Praveen MR, Shah GD, Vasavada AR, Dave KH. The effect of single-piece hydrophobic acrylic intraocular lenses on the development of posterior capsule opacification. Am J Ophthalmol 2015; 160:470-478.e1. [PMID: 26067189 DOI: 10.1016/j.ajo.2015.05.037] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2015] [Revised: 05/29/2015] [Accepted: 05/29/2015] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the long-term effect of a single-piece hydrophobic acrylic intraocular lens (IOL), AcrySof SN60AT (Alcon Laboratories, Fort Worth, Texas, USA), on the development of posterior capsule opacification (PCO) 5 years postoperatively. DESIGN Prospective, observational, consecutive, case series. METHODS setting: Iladevi Cataract and IOL Research Center, Ahmedabad, India. STUDY POPULATION Three hundred and ninety eyes with uncomplicated age-related cataract were included. Patients with diabetes mellitus, glaucoma, high myopia, pseudoexfoliation, traumatic cataract, subluxated cataract, previous ocular surgeries, and allergy to dilating drops were excluded. intervention procedures: Digital retroillumination photographic documentation was performed and analyzed for PCO using Evaluation of Posterior Capsule Opacification software. The scores and areas were calculated. MAIN OUTCOME MEASURES PCO development and the influence of the anterior capsule cover (total on and part on) on the IOL optic was studied within the capsulorrhexis margin and the central 3.0 mm optic area. RESULTS There was a significant increase in PCO up to 3 years. No significant change in PCO was observed between 3 and 5 years within the capsulorrhexis margin and central 3.0 mm optic area. In the total on group, within the capsulorrhexis margin, significantly lower scores and areas were observed when compared with part-on scores and areas. CONCLUSION The increase in PCO up to 3 years was significant. Stabilization in PCO was observed between 3 and 5 years with no difference at 5 years. There was a low incidence of PCO in eyes with total anterior capsule cover over the IOL optic.
Collapse
Affiliation(s)
- Mamidipudi R Praveen
- Iladevi Cataract & IOL Research Center, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India
| | - Gauri D Shah
- Iladevi Cataract & IOL Research Center, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India
| | - Abhay R Vasavada
- Iladevi Cataract & IOL Research Center, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India.
| | - Khyati H Dave
- Iladevi Cataract & IOL Research Center, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India
| |
Collapse
|
15
|
Schriefl SM, Leydolt C, Stifter E, Menapace R. Posterior capsular opacification and Nd:YAG capsulotomy rates with the iMics Y-60H and Micro AY intra-ocular lenses: 3-year results of a randomized clinical trial. Acta Ophthalmol 2015; 93:342-7. [PMID: 25393894 DOI: 10.1111/aos.12543] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Accepted: 07/23/2014] [Indexed: 11/27/2022]
Abstract
PURPOSE To compare the incidence and intensity of posterior capsular opacification (PCO) and neodymium:yttrium-aluminium-garnet (Nd:YAG) capsulotomy rates between two microincision intra-ocular lenses (IOLs) 3 years after surgery. METHODS Sixty-five patients randomly received a Y-60H IOL (HOYA Surgical Optics, Singapore) in one eye and a Micro AY IOL (PhysIOL, Liège, Belgium) in the contralateral eye during same-day bilateral cataract surgery. Eyes were examined 1 week, 20 months and 3 years after surgery. The amount of PCO (score: 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software (aqua). Additionally, the Nd:YAG capsulotomy rate was noted. RESULTS Three years postoperatively, the objective PCO score of Y-60H IOLs was 1.9 ± 1.7 compared to PCO score of 1.7 ± 2.2 for the Micro AY IOLs (p = 0.66). Thirty-four percentage of the Y-60H eyes had undergone Nd:YAG capsulotomy, compared to 49% of the Micro AY eyes (p = 0.04). Significantly, more capsular folds were observed in the Y-60H IOL group (p = 0.001). There was no significant difference in best-corrected visual acuity, rhexis/IOL overlap and anterior capsule opacification 3 years after surgery. CONCLUSION Both microincision IOLs showed high YAG rates and comparable PCO scores 3 years after surgery. In the light of this unsatisfying PCO performance, the advantage of the present microincision IOLs over conventional IOLs must be questioned.
Collapse
Affiliation(s)
- Sabine M. Schriefl
- Department of Ophthalmology; Medical University of Vienna; Vienna Austria
| | - Christina Leydolt
- Department of Ophthalmology; Medical University of Vienna; Vienna Austria
| | - Eva Stifter
- Department of Ophthalmology; Medical University of Vienna; Vienna Austria
| | - Rupert Menapace
- Department of Ophthalmology; Medical University of Vienna; Vienna Austria
| |
Collapse
|
16
|
Brookshire HL, English RV, Nadelstein B, Weigt AK, Gift BW, Gilger BC. Efficacy of COX-2 inhibitors in controlling inflammation and capsular opacification after phacoemulsification cataract removal. Vet Ophthalmol 2014; 18:175-85. [PMID: 24636042 DOI: 10.1111/vop.12159] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To evaluate the efficacy of 0.9% bromfenac (Xibrom™) or a celecoxib-impregnated intraocular lens (celecoxib-IOL) compared with 1% prednisolone acetate (PA) in controlling postoperative inflammation and posterior capsule opacification (PCO). ANIMAL STUDIED Fifty-nine dogs undergoing cataract extraction by phacoemulsification. PROCEDURE Bilateral patients received bromfenac or celecoxib-IOL plus PA in one eye, and PA in the contralateral eye. Unilateral patients received bromfenac or PA. Complete ophthalmic examination including tonometry, slit-lamp grading of flare and PCO, and digital image acquisition for masked PCO evaluation was performed within 24 h and 1, 4, 12, 24, and 56 weeks following surgery. RESULTS Celecoxib-IOL/PA-treated eyes had significantly less flare than PA-treated eyes, which had significantly less flare than bromfenac-treated eyes 24 h postoperatively. There was no significant difference in intraocular pressure (IOP) postoperatively, or at 1, 24, or 56 weeks. Celecoxib-IOL/PA-treated eyes had significantly lower IOP measurements than bromfenac and PA-treated eyes at 4 and 12 weeks. There was no significant difference in PCO level between groups using slit-lamp biomicroscopy at any time point. Masked evaluation of digital images revealed significantly less PCO in celecoxib-IOL/PA- vs. bromfenac-treated eyes at 4 weeks, and in bromfenac- vs. PA-treated eyes at 56 weeks. CONCLUSIONS Eyes receiving celecoxib-IOL/PA had better initial control of inflammation. Bromfenac was equally effective compared with PA in controlling inflammation. There was no association between COX-2 inhibitor administration and ocular hypertension. Celecoxib-IOL/PA-treated eyes showed better initial control of PCO (up to 12 weeks), while eyes receiving bromfenac had better long-term control of PCO (56 weeks).
Collapse
|
17
|
Kabata Y, Takahashi G, Tsuneoka H. Neodymium:yttrium-aluminum garnet capsulotomy rates after combined cataract surgery with implantation of a 4% water content hydrophobic acrylic intraocular lens and vitrectomy. Clin Ophthalmol 2013; 7:2215-8. [PMID: 24235813 PMCID: PMC3825697 DOI: 10.2147/opth.s54467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND The purpose of this study was to examine neodymium:yttrium-aluminum garnet (Nd:YAG) capsulotomy rates after combined cataract surgery with implantation of a three-piece 4% water content hydrophobic acrylic intraocular lens (X-70, Eternity®) and vitrectomy, and compare diabetic retinopathy with nondiabetic retinopathy. METHODS Nd:YAG capsulotomy rates were evaluated for 72 eyes of 72 patients with diabetic retinopathy and 81 eyes of 81 patients with nondiabetic retinopathy (50 eyes with retinal detachment, 13 eyes with macular hole, nine eyes with epiretinal membrane, seven eyes with branch retinal vein occlusion, and two eyes with uveitis) who underwent combined cataract surgery and vitrectomy and implantation of X-70. RESULTS Two years after combination surgery, four of 72 eyes (5.6%) in the diabetic retinopathy group and four of 81 eyes (5.0%) in the nondiabetic retinopathy group required Nd:YAG capsulotomies. Kaplan-Meier survival analysis showed no statistically significant differences between the two groups (P=0.30, Mantel-Cox log-rank test). CONCLUSION The rate of Nd:YAG capsulotomy did not significantly differ between diabetic retinopathy and nondiabetic retinopathy after combined cataract surgery with implantation of the X-70 and vitrectomy. X-70 is an acceptable intraocular lens for patients undergoing combined cataract surgery and vitrectomy.
Collapse
Affiliation(s)
- Yoshiaki Kabata
- Department of Ophthalmology, Jikei University School of Medicine, Katsushika Medical Center, Tokyo, Japan
| | | | | |
Collapse
|
18
|
Morgan-Warren PJ, Smith JA. Intraocular lens-edge design and material factors contributing to posterior-capsulotomy rates: comparing Hoya FY60aD, PY60aD, and AcrySof SN60WF. Clin Ophthalmol 2013; 7:1661-7. [PMID: 24003302 PMCID: PMC3755701 DOI: 10.2147/opth.s48824] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To compare neodymium-doped yttrium aluminum garnet laser posterior capsulotomy (LPC) rates between the Hoya FY60AD, Hoya PY60AD, and Alcon AcrySof SN60WF intraocular lenses (IOLs) after routine cataract surgery. METHODS In this retrospective comparative study, patients undergoing uncomplicated cataract surgery over a 3-year period were included, and those subsequently undergoing LPC were identified from laser clinic records. LPC rates at 2 years postoperatively were compared between the round-edged Hoya FY60AD, the newer sharp-edged Hoya PY60AD three-piece IOLs, and the one-piece AcrySof SN60WF IOL. RESULTS A total of 1,265 cataract operations were included, and 49 eyes (3.9%) underwent LPC within 2 years of surgery. Twenty-eight of 315 eyes (8.9%) implanted with the FY60AD underwent LPC by 2 years, compared to eleven of 254 (4.3%) with the newer sharp square-edged PY60AD and ten of 696 (1.4%) with the one-piece SN60WF (P < 0.05, Chi-squared analyses). CONCLUSIONS The newer, sharper-edged Hoya PY60AD IOL has a lower LPC rate than the Hoya FY60AD IOL at 2 years post-cataract surgery. The one-piece AcrySof SN60WF has a lower LPC rate than both the three-piece Hoya IOLs in the same time period postoperatively. Variations in IOL-edge design and material effect may have contributed to the different rates observed.
Collapse
|
19
|
Yoo YS, Yang JW, Lee YC, Kim SY. Incidence and Risk Factors of Nd:YAG Capsulotomy in Adult Cataract Patients Younger than 50 Years of Age. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2013. [DOI: 10.3341/jkos.2013.54.9.1339] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Young Sik Yoo
- Department of Ophthalmology & Visual Science College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Ji Wook Yang
- Department of Ophthalmology & Visual Science College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Young Chun Lee
- Department of Ophthalmology & Visual Science College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Su Young Kim
- Department of Ophthalmology & Visual Science College of Medicine, The Catholic University of Korea, Seoul, Korea
| |
Collapse
|
20
|
Shah VC, Russo C, Cannon R, Davidson R, Taravella MJ. Incidence of Nd:YAG capsulotomy after implantation of AcrySof multifocal and monofocal intraocular lenses: a case controlled study. J Refract Surg 2011; 26:565-8. [PMID: 20349858 DOI: 10.3928/1081597x-20100303-01] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2009] [Accepted: 02/02/2010] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the frequency of posterior capsulotomies in patients receiving a multifocal or monofocal intraocular lens (IOL) of a similar design following cataract extraction. METHODS Four hundred seventeen eyes underwent cataract extraction and IOL implantation; 275 eyes received the AcrySof SN6OWF (Alcon Laboratories Inc) one-piece monofocal lens (monofocal group) and 142 eyes received the RESTOR multifocal lens (SN60D3 or SA60D3, Alcon Laboratories Inc) (multifocal group). Surgery was performed by two surgeons at one site. Primary outcome measures were incidence, time of onset, and preoperative corrected distance visual acuity (CDVA) for those patients receiving posterior capsulotomies. RESULTS After average 22-month postoperative follow-up (range: 2 to 41 months), 22 (15.49%) eyes in the multifocal group underwent posterior capsulotomies compared with 16 (5.82%) eyes in the monofocal group (P = .0014). The main indication for Nd:YAG laser capsulotomy in the multifocal group was complaint of poor quality of vision rather than decreased CDVA. The multifocal group underwent capsulotomies after a mean of 8.8 months (range: 1.7 to 29.2 months), whereas the monofocal group required capsulotomies after a mean of 10.4 months (range: 0.8 to 28.6 months) (P = .559). Mean logMAR CDVA before capsulotomy was 0.113 (range: 0 to 0.6) for the multifocal group and 0.244 (range: 0 to 0.48) for the monofocal group (P = .073). CONCLUSIONS Use of the RESTOR multifocal IOL in clinical practice may result in more frequent Nd:YAG laser capsulotomies. Reasons for this may include increased visual demands of patients receiving presbyopic-correcting IOLs or complex visual phenomena associated with the interaction of multifocal optics and posterior capsule opacification.
Collapse
Affiliation(s)
- Vipul C Shah
- University of Colorado at Denver Health Science Center, Denver, Colorado, USA
| | | | | | | | | |
Collapse
|
21
|
Gayton JL, Seabolt RA. Clinical Outcomes of Complex and Uncomplicated Cataractous Eyes After Lens Replacement with the AcrySof Toric IOL. J Refract Surg 2011; 27:56-62. [DOI: 10.3928/1081597x-20100325-01] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2009] [Accepted: 02/16/2010] [Indexed: 11/20/2022]
|
22
|
Baile R, Sahasrabuddhe M, Nadkarni S, Karira V, Kelkar J. Effect of anterior capsular polishing on the rate of posterior capsule opacification: A retrospective analytical study. Saudi J Ophthalmol 2010; 26:101-4. [PMID: 23960976 DOI: 10.1016/j.sjopt.2010.11.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2010] [Revised: 11/29/2010] [Accepted: 11/30/2010] [Indexed: 10/18/2022] Open
Abstract
AIM To determine whether anterior capsule polishing during cataract surgery done by phacoemulsification has any effect on the rate of posterior capsule opacification. MATERIALS AND METHODS We conducted a 3 year retrospective analytical study at our hospital. The medical records of patients who underwent cataract extraction by phacoemulsification with foldable square edge hydrophilic PCIOL between April 2007 and March 2010 were reviewed. The study included 1009 eyes of 950 patients who underwent phacoemulsification with foldable square edge hydrophilic IOL in the bag implantation with anterior capsular polishing. The control group included 981 eyes of 957 patients in whom anterior capsular polishing was not done. Patients in the age group of 45-65 years with well dilating pupils were included in the study. They were evaluated at 1 week, 1 month and 1 year post-operatively. Exclusion criteria included glaucoma, shallow anterior chamber, uveitis, high myopia, pseudoexfoliation, diabetes mellitus, traumatic cataracts, posterior polar cataract, subluxated cataracts, previous ocular surgeries, patients allergic to dilating drops, and steroid intake. Intraoperatively, the exclusion criteria were not achieving the total anterior capsule cover on the IOL optic, sulcus fixated IOL, and any intraoperative complications like posterior capsule rupture. After bimanual irrigation/aspiration, all enrolled patients were randomly assigned to receive either 360 degree anterior capsular polishing or No anterior capsular polishing and results were studied. RESULTS The rate of posterior capsule opacification in the study group and in the control group was not statistically significant. CONCLUSION Though it was thought that anterior capsular polishing will lead to reduced rate of PCO formation, our study showed that there was no significant difference in PCO formation between the two groups. However, it was seen that the rate of anterior capsule opacification and capsular phimosis showed a significant reduction in cases in which anterior capsular polishing was done.
Collapse
Affiliation(s)
- Rahul Baile
- Department of Ophthalmology, BARC Hospital, Mumbai, India
| | | | | | | | | |
Collapse
|
23
|
Mathew RG, Coombes AGA. Reduction of Nd:YAG capsulotomy rates after implantation of a single-piece acrylic hydrophilic intraocular lens with 360° squared optic edge: 24-month results. Ophthalmic Surg Lasers Imaging Retina 2010; 41:651-5. [PMID: 20954645 DOI: 10.3928/15428877-20100929-04] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2010] [Accepted: 07/29/2010] [Indexed: 11/20/2022]
Abstract
BACKGROUND AND OBJECTIVE Posterior capsule opacification remains a significant problem following cataract surgery. The aim of the study was to evaluate the incidence of symptomatic posterior capsule opacification requiring Nd:YAG capsulotomy in patients who underwent cataract extraction and implantation of the Rayner C-flex 570C intraocular lens (IOL) (Rayner Intraocular Lens, Ltd., Sussex, UK). PATIENTS AND METHODS A retrospective study of 3,461 eyes that underwent cataract extraction and insertion of the Rayner C-flex IOL from January 2004 to December 2005. The cases that received Nd: YAG capsulotomies were evaluated. RESULTS Over a 24-month period, 3,461 Rayner C-flex IOLs were implanted. Nd:YAG capsulotomy was performed in 58 of these cases. The rate of Nd:YAG capsulotomy was 0.6% at 12 months and 1.7% at 24 months. The mean time to Nd:YAG capsulotomy was 9.3 months (range: 1.3 to 22.7 months). The follow-up period was 5.3 to 29.0 months. CONCLUSION The incidence of symptomatic posterior capsule opacification with the Rayner C-flex IOL is low.
Collapse
|
24
|
Nekolová J, Jirásková N, Pozlerová J, Rozsíval P. Three-year follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification. Am J Ophthalmol 2009; 148:390-5. [PMID: 19427990 DOI: 10.1016/j.ajo.2009.03.027] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2008] [Revised: 03/11/2009] [Accepted: 03/16/2009] [Indexed: 10/20/2022]
Abstract
PURPOSE To prospectively compare the degree of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods during the 3-year follow-up period. DESIGN Prospective, randomized clinical trial. METHODS Setting at the Department of Ophthalmology, University Hospital in Hradec Králové. Patients with bilateral cataract were included. AquaLase was used in the right eye and NeoSoniX in the left eye of each patient. The AcrySof SA60AT intraocular lens (Alcon Laboratories, Fort Worth, Texas, USA) was implanted in all eyes. The Evaluation of Posterior Capsule Opacification (EPCO) 2000 software (Developed by Tetz MR and associates, Berlin, Germany) and the Open-Access Systematic Capsule Assessment (OSCA) system (Devised by Aslam TM, Edinburgh, United Kingdom) were used for PCO assessment 1, 2, and 3 years after cataract surgery. RESULTS Fifty patients were analyzed 1 year, 47 patients 2 years, and 46 patients 3 years after cataract surgery. Mean EPCO 2000 values were for the AquaLase group 0.324 +/- 0.305 and for the NeoSoniX group 0.298 +/- 0.341 (P = .53) 1 year after surgery, for the AquaLase group 0.429 +/- 0.322 and for the NeoSoniX group 0.478 +/- 0.337 (P = .30) 2 years after surgery, and for the AquaLase group 0.582 +/- 0.506 and for the NeoSoniX group 0.594 +/- 0.515 (P = .87) 3 years after surgery. The OSCA results were for the AquaLase group 0.7097 +/- 0.3778 and for the NeoSoniX group 0.8584 +/- 0.4323 (P = .046) 1 year after surgery, for the AquaLase group 0.7515 +/- 0.4555 and for the NeoSoniX group 0.8103 +/- 0.4498 (P = .44) 2 years after surgery, and for the AquaLase group 0.9667 +/- 0.736 and for the NeoSoniX group 0.9540 +/- 0.5250 (P = .91) 3 years after surgery. Neodymium-yttrium-aluminun-garnet capsulotomy rate for AquaLase vs NeoSoniX was 0:1 eyes 1 year, 1:3 eyes 2 years, and 1:4 eyes 3 years after surgery. No significant difference between those 2 groups was established, except the OSCA outcomes 1 year postoperatively. CONCLUSION There was only minimal PCO difference between these 2 approaches, AquaLase and NeoSoniX. Neither AquaLase nor NeoSoniX technique was able to prevent a natural progression of PCO.
Collapse
|
25
|
Vasavada AR, Shah A, Raj SM, Praveen MR, Shah GD. Prospective evaluation of posterior capsule opacification in myopic eyes 4 years after implantation of a single-piece acrylic IOL. J Cataract Refract Surg 2009; 35:1532-9. [DOI: 10.1016/j.jcrs.2009.04.039] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2009] [Revised: 04/07/2009] [Accepted: 04/13/2009] [Indexed: 10/20/2022]
|
26
|
Nekolová J, Pozlerová J, Jirásková N, Rozsíval P, Kadlecová J. Comparison of posterior capsule opacification after two different surgical methods of cataract extraction. Am J Ophthalmol 2008; 145:493-498. [PMID: 18201683 DOI: 10.1016/j.ajo.2007.10.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2007] [Revised: 10/24/2007] [Accepted: 10/29/2007] [Indexed: 11/19/2022]
Abstract
PURPOSE To compare the extent of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods using two types of software for PCO quantification. DESIGN Prospective, randomized clinical trial. METHODS At the Department of Ophthalmology, University Hospital in Hradec Králové, 50 patients (100 eyes) were analyzed one year after surgery. AquaLase was used in the right eye and NeoSoniX in the left eye of each patient. One year after surgery, digital retroillumination photographs of anterior segments were obtained. The Evaluation of Posterior Capsule Opacification (EPCO) 2000 software (Berlin, Germany) and the Open-Access Systematic Capsule Assessment (OSCA) system (Edinburgh, United Kingdom) were used for PCO assessment. Best-corrected Snellen visual acuity (BCVA) was evaluated before and after surgery. Statistical analysis was performed using parametric tests. RESULTS The EPCO 2000 results were as follows: mean value for right eyes, 0.324+/-0.305; mean value for left eyes, 0.298+/-0.341; no difference was proved (P=.532). The OSCA results were as follows: for right eyes, 0.7097+/-0.3777; for left eyes, 0.8584+/-0.4323; significant difference (P=.046), worse for left eyes. No correlation between EPCO 2000 and OSCA results was established (P>.001; correlation coefficient, 0.347). BCVA for the right eyes was 0.837+/-0.262 and for the left eyes was 0.849+/-0.224. Neodymium:yytrium-aluminum-garnet capsulotomy was performed in one eye in the NeoSoniX group, and in no eyes in the AquaLase group. CONCLUSIONS There was no significant difference in PCO measured by EPCO 2000, however, PCO after AquaLase as assessed by EPCO 2000 was slightly denser. The OSCA system gave significantly higher scores in the NeoSoniX group. No correlation between EPCO 2000 and OSCA outcomes was proved.
Collapse
Affiliation(s)
- Jana Nekolová
- Department of Ophthalmology, University Hospital in Hradec Králové, Hradec Králové, Czech Republic.
| | | | | | | | | |
Collapse
|
27
|
Heo H, Kim HG, Yoon KC, Park YG. Comparison of Long-Term Results between One-piece and Three-piece Acrylate Intraocular Lens. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2008. [DOI: 10.3341/jkos.2008.49.2.245] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Hwan Heo
- Department of Ophthalmology, Chonnam National University Medical School & Hospital, Chonnam National Research Institute for Medical Sciences, Gwangju, Korea
| | - Hwang Gyun Kim
- Department of Ophthalmology, Chonnam National University Medical School & Hospital, Chonnam National Research Institute for Medical Sciences, Gwangju, Korea
| | - Kyung Chul Yoon
- Department of Ophthalmology, Chonnam National University Medical School & Hospital, Chonnam National Research Institute for Medical Sciences, Gwangju, Korea
| | - Yeoung-Geol Park
- Department of Ophthalmology, Chonnam National University Medical School & Hospital, Chonnam National Research Institute for Medical Sciences, Gwangju, Korea
| |
Collapse
|
28
|
Effect of square-edged intraocular lenses on neodymium:YAG laser capsulotomy rates in the United States. J Cataract Refract Surg 2007; 33:1899-906. [DOI: 10.1016/j.jcrs.2007.06.056] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2007] [Accepted: 06/26/2007] [Indexed: 11/15/2022]
|
29
|
Leydolt C, Davidovic S, Sacu S, Menapace R, Neumayer T, Prinz A, Buehl W, Findl O. Long-term Effect of 1-Piece and 3-Piece Hydrophobic Acrylic Intraocular Lens on Posterior Capsule Opacification. Ophthalmology 2007; 114:1663-9. [PMID: 17822973 DOI: 10.1016/j.ophtha.2006.12.016] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2006] [Revised: 12/11/2006] [Accepted: 12/11/2006] [Indexed: 10/22/2022] Open
Abstract
PURPOSE To compare the intensity of posterior capsule opacification (PCO) between the 1-piece and 3-piece haptic designs of the foldable hydrophobic acrylic AcrySof intraocular lens (IOL) over a 5-year period. DESIGN Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison. PARTICIPANTS Fifty-two patients with bilateral age-related cataract (104 eyes). METHODS Each study patient had cataract surgery in both eyes and received a 1-piece AcrySof IOL in 1 eye and a 3-piece AcrySof IOL in the other eye. Follow-up examinations were performed at 1 week, 1 month, 6 months, and 1, 2, and 5 years. Digital retroillumination images were obtained of each eye. The amount of posterior capsule opacification (score range, 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software 1, 2, and 5 years after surgery. MAIN OUTCOME MEASURE Posterior capsule opacification score (scale, 0-10). RESULTS There was no significant difference between the 1-piece and 3-piece AcrySof IOL in best-corrected visual acuity, overlap of rhexis and IOL, capsular folds, anterior capsule opacification, and posterior capsule opacification (1-piece AcrySof PCO score, 1.7+/-1.7; 3-piece AcrySof PCO score, 1.3+/-1.4; P = 0.30). CONCLUSIONS Modification of the IOL haptic design of the sharp optic edged AcrySof IOL from a 3-piece to a 1-piece haptic design caused no significant change in PCO intensity and neodymium:yttrium-aluminium-garnet laser treatment rate 5 years after surgery.
Collapse
Affiliation(s)
- Christina Leydolt
- Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Johnson SH. August Consultation # 3. J Cataract Refract Surg 2007. [DOI: 10.1016/j.jcrs.2007.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
31
|
Zemaitiene R, Jasinskas V, Auffarth GU. Influence of three-piece and single-piece designs of two sharp-edge optic hydrophobic acrylic intraocular lenses on the prevention of posterior capsule opacification: a prospective, randomised, long-term clinical trial. Br J Ophthalmol 2006; 91:644-8. [PMID: 17124239 PMCID: PMC1954737 DOI: 10.1136/bjo.2006.103648] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
BACKGROUND Posterior capsule opacification (PCO) is still a major long-term complication of modern cataract surgery. We evaluated the impact of sharp-edged intraocular lenses (IOLs) with different haptic designs made from the same hydrophobic acrylic material on posterior and anterior lens capsule opacification. SETTING Eye clinic of Kaunas University of Medicine, Lithuania. Prospective randomised clinical study. METHODS Seventy-four eyes of 74 patients scheduled for cataract surgery were included in a prospective randomised clinical study. Thirty-seven eyes of 37 patients received a three-piece acrylic hydrophobic (AcrySof, MA3OBA, Alcon) IOL; and thirty-seven eyes of 37 patients received a one-piece acrylic hydrophobic (AcrySof, SA3OAL, Alcon) IOL. Visual acuity, anterior capsule opacification (ACO), capsular folds, capsulorrhexis/optic overlapping and posterior capsule opacification (PCO) were evaluated. ACO was assessed subjectively. PCO values in the entire IOL optic area and in the central 3 mm optic zone were assessed using a photographic image-analysis system (EPCO2000). Follow-ups were performed postoperatively at 1 day, 6 months, 1 year and 2 years. RESULTS There were no significant differences in best corrected visual acuity, grade of ACO and capsulorrhexis/optic overlapping between IOL types during the follow-up period. Patients in the one-piece acrylic hydrophobic IOL group more frequently presented with capsular folds behind the IOL optic area than those in the three-piece IOL group. In the three-piece acrylic hydrophobic IOL group, PCO values (mean (SD)) of the entire IOL optic area were significantly lower six months postoperative (three-piece: 0.002 (0.009); one-piece: 0.007 (0.017); p=0.04), one year postoperative (three-piece: 0.004 (0.016); one-piece: 0.026 (0.041); p=0.001) as well as one year postoperative in the central 3 mm optic zone (three-piece: 0.000 (0.0002); one-piece: 0.019 (0.049); p=0.001). However, two years postoperative, the PCO values of the groups did not show significant differences (entire IOL optic area: three-piece, 0.136 (0.223); one-piece, 0.154 (0.190); p=0.18; central zone: three-piece, 0.023 (0.065); one-piece: 0.020 (0.039); p=0.44). CONCLUSION The 2 year follow-up after cataract surgery showed no significant difference in ACO and PCO development between three-piece and one-piece acrylic hydrophobic intraocular lenses.
Collapse
Affiliation(s)
- Reda Zemaitiene
- Eye Clinic of Kaunas University of Medicine, Mickeviciaus 9, LT 44307 Kaunas, Lithuania.
| | | | | |
Collapse
|
32
|
Nixon DR, Apple DJ. Evaluation of lens epithelial cell migration in vivo at the haptic-optic junction of a one-piece hydrophobic acrylic intraocular lens. Am J Ophthalmol 2006; 142:557-62. [PMID: 17011844 DOI: 10.1016/j.ajo.2006.05.049] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2005] [Revised: 05/11/2006] [Accepted: 05/21/2006] [Indexed: 11/19/2022]
Abstract
PURPOSE To evaluate the pattern of lens epithelial cell (LEC) ingrowth behind the intraocular lens (IOL) optic in patients implanted with the AcrySof SA60AT one-piece IOL. DESIGN Retrospective case series. METHODS Patients implanted with the AcrySof SA60AT one-piece IOL with complete overlap of the capsulorrhexis and IOL optic and no ocular pathology were selected from the practices of six surgeons. High-resolution digital images of the distribution of LECs were captured. Circumferential location and extent of LEC growth behind the optic were measured. RESULTS Mean +/- SD follow-up was 13.2 +/- 1.7 months for 40 patients (mean age 72 years). LEC migration beyond the edge of the IOL optic was displayed by 57.5% (23/40) of patients. LECs migrated into the visual axis in 22.5% (9/40) of patients, leading to a visual acuity of <6/9 (20/30) in 10% (4/40) of patients. Cell migration was located preferentially at the optic-haptic junction. Serial photographs were used to monitor LEC migration over time. In some cases, LECs extended from the opposing optic-haptic junctions to converge in the center of the IOL, creating a path across the optic. CONCLUSIONS The optic-haptic junction of the AcrySof one-piece IOL is a point of weakness in the barrier effect of the square-edge IOL design that provides migrating LECs access to the posterior capsule.
Collapse
|
33
|
|