Mulvihill C, McDonald D. Standardized neonatal continuous infusion concentrations: A quality improvement initiative.
Am J Health Syst Pharm 2023;
80:61-67. [PMID:
36255033 DOI:
10.1093/ajhp/zxac299]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Indexed: 01/19/2023] Open
Abstract
PURPOSE
Medication errors are a significant and preventable source of patient harm, especially in the neonatal population. Standardized infusion concentrations increase patient safety and streamline the workflow for pharmacists, nurses, and physicians.
METHODS
Neonatal continuous infusion concentrations were standardized and implemented into the electronic health record using an automated order panel. Pre- and postimplementation data were collected to assess the impact of this quality improvement initiative. The primary endpoint was the proportion of neonatal intensive care unit infusion orders that were compatible with "bolus from infusion" functionality in the syringe pump.
RESULTS
Before implementation, only 40% of eligible infusions were compatible with the "bolus from infusion" function, compared to 93% after implementation (P < 0.00001). Within the syringe pump, the ratio of total options to the number of concentrations per medication was reduced by 31%.
CONCLUSION
Implementation of an order panel with defaulted standard infusion concentration selection improved workflow and optimized technology in the neonatal intensive care unit.
Collapse