1
|
Guru S, Singh N, Sahoo S, Hansda U, Mohanty C. Comparison of endotracheal intubation with Macintosh versus King Vision video laryngoscope using coronavirus disease 2019 barrier box on manikins: A randomized crossover study. Turk J Emerg Med 2022; 22:149-155. [PMID: 35936952 PMCID: PMC9355073 DOI: 10.4103/2452-2473.348436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 05/06/2022] [Accepted: 05/17/2022] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND: Coronavirus disease 2019 (COVID-19) virus usually spreads through aerosol and close contact. Frontline health-care workers handle aerosol-generating procedures like endotracheal intubation. To reduce this risk, COVID-19 barrier box came into the picture. However, the COVID-19 barrier box may compromise easy and successful intubation, and their limitation must be studied. OBJECTIVES: The objective of this study was to assess the time to successful intubation with or without the COVID-19 barrier box using the Macintosh laryngoscope and King Vision video laryngoscope (KVVL). We also assessed the first-pass success rate, ease of intubation, Cormack–Lehane (CL) grade, and requirement of external laryngeal manipulation. METHODS: We conducted this manikin-based randomized crossover study to assess the time to successful intubation by anesthesiologists (22) and emergency physicians (11) having 1 year or more experience with or without COVID-19 barrier box by using the Macintosh laryngoscope and KVVL. Our study randomized the sequence of the four different intubation scenarios. RESULTS: The comparison of mean duration of intubation between KVVL (13.21 ± 4.05 s) and Macintosh laryngoscope (12.89 ± 4.28 s) with COVID-19 barrier box was not statistically significant (95% confidence interval: 1.21–0.97). The ease of intubation, number of attempts, and requirement of external laryngeal manipulation were not statistically significant. Intubations were statistically significant more difficult with barrier box in view of higher CL grade. CONCLUSION: Time to intubation was longer with COVID-19 barrier box using KVVL as compared to Macintosh laryngoscope which was statistically not significant.
Collapse
Affiliation(s)
- Satyabrata Guru
- Department of Trauma and Emergency, AIIMS, Bhubaneswar, Odisha, India
| | - Neha Singh
- Department of Anaesthesiology, AIIMS, Bhubaneswar, Odisha, India
| | - Sangeeta Sahoo
- Department of Trauma and Emergency, AIIMS, Bhubaneswar, Odisha, India
| | - Upendra Hansda
- Department of Trauma and Emergency, AIIMS, Bhubaneswar, Odisha, India
| | | |
Collapse
|
2
|
Hamal PK, Yadav RK, Malla P. Performance of custom made videolaryngoscope for endotracheal intubation: A systematic review. PLoS One 2022; 17:e0261863. [PMID: 34990475 PMCID: PMC8735609 DOI: 10.1371/journal.pone.0261863] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 12/10/2021] [Indexed: 01/08/2023] Open
Abstract
Introduction Videolaryngoscope is regarded as the standard of care for airway management in well-resourced setups however the technology is largely inaccessible and costly in middle and low-income countries. An improvised and cost-effective form of customized videolaryngoscope was proposed and studied for patient care in underprivileged areas however there were no distinct conclusions on its performances. Method The study follows PRISMA guidelines for systematic review and the protocol in International Prospective Register for Systematic Reviews. The primary aim was to assess the first attempt success of customized videolaryngoscope for endotracheal intubation. The secondary objective was to evaluate the number of attempts, laryngoscopic view in terms of Cormack Lehane score and Percentage of glottic opening, use of external laryngeal maneuver and stylet and, the airway injuries after the endotracheal intubation. Result Five studies were analyzed for risk of bias using the National Institute of Health Quality Assessment Tool for cross-sectional studies. Most of the studies had a poor to a fair level of evidence with only one study with a good level of evidence. Certainty of evidence was “very low” for all eligible studies when graded using the Grading of Recommendation, Assessment, Development and Evaluation approach for systematic review. Conclusions The certainty of the evidence regarding performance of custom-made videolaryngoscope compared to conventional laryngoscope was very low and the study was performed in small numbers with fair to the poor risk of bias. It was difficult to establish and do further analysis regarding whether the customized form of videolaryngoscope will improve the first attempt success rate for tracheal intubation, reduce the number of attempts, improve the laryngoscopic view, require fewer external aids and reduce the incidences of airway injury with the given low-grade evidence. Some properly conducted randomised clinical trials will be required to further analyze the outcome and make the strong recommendations.
Collapse
Affiliation(s)
- Pawan Kumar Hamal
- Department of Anaesthesiology and Intensive Care, National Trauma Center, National Academy of Medical Sciences, Mahankal, Kathmandu, Nepal
- * E-mail:
| | - Rupesh Kumar Yadav
- Department of Anaesthesiology and Intensive Care, National Trauma Center, National Academy of Medical Sciences, Mahankal, Kathmandu, Nepal
| | - Pragya Malla
- Department of Biochemistry, Nepal Medical College and Teaching Hospital, Kathmandu, Nepal
| |
Collapse
|
3
|
Comparing the McGrath Mac Video Laryngoscope and Direct Laryngoscopy for Prehospital Emergency Intubation in Air Rescue Patients: A Multicenter, Randomized, Controlled Trial. Crit Care Med 2020; 47:1362-1370. [PMID: 31389835 PMCID: PMC6791500 DOI: 10.1097/ccm.0000000000003918] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Supplemental Digital Content is available in the text. Tracheal intubation in prehospital emergency care is challenging. The McGrath Mac Video Laryngoscope (Medtronic, Minneapolis, MN) has been proven to be a reliable alternative for in-hospital airway management. This trial compared the McGrath Mac Video Laryngoscope and direct laryngoscopy for the prehospital setting.
Collapse
|
4
|
Yu J, Hu R, Wu L, Sun P, Zhang Z. A comparison between the Disposcope endoscope and fibreoptic bronchoscope for nasotracheal intubation: a randomized controlled trial. BMC Anesthesiol 2019; 19:163. [PMID: 31438861 PMCID: PMC6706907 DOI: 10.1186/s12871-019-0834-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 08/18/2019] [Indexed: 11/16/2022] Open
Abstract
Background Nasotracheal intubation (NTI) is frequently performed for oral and maxillofacial surgeries. This study evaluated whether NTI is easier when guided by Disposcope endoscopy or fibreoptic bronchoscopy. Methods Sixty patients (30 per group) requiring NTI were randomly assigned to undergo fibreoptic bronchoscopy-guided (fibreoptic group) or Disposcope endoscope-guided (Disposcope group) NTI. The NTI time, which was defined as the time from when the fibreoptic bronchoscope or aseptic suction catheter was inserted into the nasal cavity to the time at which the tracheal tube was correctly inserted through the glottis, was recorded. Epistaxis was evaluated by direct laryngoscopy five minutes after completing NTI and was scored as one of four grades according to the following modified criteria: no epistaxis, mild epistaxis, moderate epistaxis, and severe epistaxis. Results The time to complete NTI was significantly longer in the fibreoptic group than in the Disposcope group (38.4 s vs 24.1 s; mean difference, 14.2 s; 95% confidence interval (CI), 10.4 to 18.1). Mild epistaxis was observed in 8 patients in the fibreoptic group and in 7 patients in the Disposcope group (26.7% vs 23.3%, respectively; relative risk, 1.2; 95% CI, 0.4 to 3.9), though no moderate or severe epistaxis occurred in either group. Furthermore, no obvious nasal pain was reported by any of the patients at any time point after extubation (P = 0.74). Conclusion NTI can be completed successfully using either fibreoptic bronchoscopy or Disposcope endoscope as a guide without any severe complications. However, compared to fibreoptic bronchoscopy, Disposcope endoscope requires less execution time (the NTI time). Trial registration This clinical research was registered at the Chinese Clinical Trial Registry (www.chictr.org.cn, ChiCTR-IPR-17011462, date of registration, May 2017).
Collapse
Affiliation(s)
- Junma Yu
- Hefei National Laboratory for Physical Sciences at the Microscale, Department of Biophysics and Neurobiology, University of Science and Technology of China, Hefei, 230027, People's Republic of China. .,Department of Anesthesiology, The First People's Hospital of Hefei, Anhui Medical University, Hefei, Anhui, 230061, People's Republic of China.
| | - Rui Hu
- Department of Anesthesiology, The First People's Hospital of Hefei, Anhui Medical University, Hefei, Anhui, 230061, People's Republic of China
| | - Lining Wu
- Department of Anesthesiology, The First People's Hospital of Hefei, Anhui Medical University, Hefei, Anhui, 230061, People's Republic of China
| | - Peng Sun
- Department of Anesthesiology, The First People's Hospital of Hefei, Anhui Medical University, Hefei, Anhui, 230061, People's Republic of China
| | - Zhi Zhang
- Hefei National Laboratory for Physical Sciences at the Microscale, Department of Biophysics and Neurobiology, University of Science and Technology of China, Hefei, 230027, People's Republic of China
| |
Collapse
|
5
|
Chen PT, Ting CK, Lee MY, Cheng HW, Chan KH, Chang WK. A randomised trial comparing real-time double-lumen endobronchial tube placement with the Disposcope ® with conventional blind placement. Anaesthesia 2019; 72:1097-1106. [PMID: 28804889 DOI: 10.1111/anae.13984] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/31/2017] [Indexed: 11/27/2022]
Abstract
Double-lumen endobronchial tube placement is challenging. This study compared double-lumen tube placement with the Disposcope® , a wireless videostylet allowing real-time visualisation, with conventional blind placement. Patients undergoing elective thoracic surgery with normal airways requiring one-lung ventilation were randomly allocated into two groups (27 patients in each group). The Disposcope was used to assist left-sided double-lumen tube placement in one group, and conventional blind placement was performed in the control group. Placement in both groups was checked with fibreoptic bronchoscopy. The Disposcope-assisted group had a shorter total mean (SD) placement time (18.6 (2.5) s vs. 21.4 (2.9) s, p < 0.001), laryngoscopy to end of auscultation time (83.4 (3.0) s vs. 93.9 (5.7) s, p < 0.001) and total operation time (130.7 (6.1) s vs. 154.5 (6.3) s, p < 0.001). In the Disposcope-assisted group, the double-lumen tube was inserted in the correct side in all patients (100.0%), whereas in the conventional group, the double-lumen tube was placed in the correct side in 25 (92.6%) patients and in the wrong side in 2 (7.4%) patients; the difference was not significant (p = 0.150). In the Disposcope-assisted group, the double-lumen tube was inserted to the optimal depth in 24 (88.9%) patients, whereas in the conventional group it was inserted to the optimal depth in one (4.0%) patient. The Disposcope increased the success rate of double-lumen tube placement, and shortened the total operation time when compared with standard placement with confirmation using fibreoptic bronchoscopy, and may replace the conventional method.
Collapse
Affiliation(s)
- P T Chen
- Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan, Republic of China.,Department of Anesthesiology, School of Medicine, National Yang-Ming University, Taipei, Taiwan, Republic of China.,School of Nursing, Taipei Medical University, Taipei, Taiwan, Republic of China
| | - C K Ting
- Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan, Republic of China.,Department of Anesthesiology, School of Medicine, National Yang-Ming University, Taipei, Taiwan, Republic of China
| | - M Y Lee
- Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan, Republic of China
| | - H W Cheng
- Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan, Republic of China
| | - K H Chan
- Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan, Republic of China.,Department of Anesthesiology, School of Medicine, National Yang-Ming University, Taipei, Taiwan, Republic of China
| | - W K Chang
- Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan, Republic of China.,Department of Anesthesiology, School of Medicine, National Yang-Ming University, Taipei, Taiwan, Republic of China.,Taipei Municipal Gan-Dau Hospital, Taipei, Taiwan, Republic of China
| |
Collapse
|
6
|
Chauvin A, Truchot J, Bafeta A, Pateron D, Plaisance P, Yordanov Y. Randomized controlled trials of simulation-based interventions in Emergency Medicine: a methodological review. Intern Emerg Med 2018; 13:433-444. [PMID: 29147942 DOI: 10.1007/s11739-017-1770-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Accepted: 11/10/2017] [Indexed: 11/27/2022]
Abstract
The number of trials assessing Simulation-Based Medical Education (SBME) interventions has rapidly expanded. Many studies show that potential flaws in design, conduct and reporting of randomized controlled trials (RCTs) can bias their results. We conducted a methodological review of RCTs assessing a SBME in Emergency Medicine (EM) and examined their methodological characteristics. We searched MEDLINE via PubMed for RCT that assessed a simulation intervention in EM, published in 6 general and internal medicine and in the top 10 EM journals. The Cochrane Collaboration risk of Bias tool was used to assess risk of bias, intervention reporting was evaluated based on the "template for intervention description and replication" checklist, and methodological quality was evaluated by the Medical Education Research Study Quality Instrument. Reports selection and data extraction was done by 2 independents researchers. From 1394 RCTs screened, 68 trials assessed a SBME intervention. They represent one quarter of our sample. Cardiopulmonary resuscitation (CPR) is the most frequent topic (81%). Random sequence generation and allocation concealment were performed correctly in 66 and 49% of trials. Blinding of participants and assessors was performed correctly in 19 and 68%. Risk of attrition bias was low in three-quarters of the studies (n = 51). Risk of selective reporting bias was unclear in nearly all studies. The mean MERQSI score was of 13.4/18.4% of the reports provided a description allowing the intervention replication. Trials assessing simulation represent one quarter of RCTs in EM. Their quality remains unclear, and reproducing the interventions appears challenging due to reporting issues.
Collapse
Affiliation(s)
- Anthony Chauvin
- Service d'Accueil des Urgences, Emergency Département, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 Rue Ambroise Paré, 75010, Paris, France.
- Faculté de Médecine, Université Diderot, Paris, France.
- INSERM U1153, Statistic and Epidemiologic Research Center Sorbonne Paris Cité (CRESS), METHODS Team, Hotel-Dieu Hospital, Paris, France.
| | - Jennifer Truchot
- Service d'Accueil des Urgences, Emergency Département, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 Rue Ambroise Paré, 75010, Paris, France
- Faculté de Médecine, Université Diderot, Paris, France
- Ilumens Simulation Department, Paris Descartes University, 45 rue des Saint Pères, 75006, Paris, France
| | - Aida Bafeta
- INSERM U1153, Statistic and Epidemiologic Research Center Sorbonne Paris Cité (CRESS), METHODS Team, Hotel-Dieu Hospital, Paris, France
| | - Dominique Pateron
- Sorbonne Universités, UPMC Paris Univ-06, Paris, France
- Service des Urgences-Hôpital Saint Antoine, Assistance Publique-Hôpitaux de Paris (APHP), Paris, France
| | - Patrick Plaisance
- Service d'Accueil des Urgences, Emergency Département, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 Rue Ambroise Paré, 75010, Paris, France
- Faculté de Médecine, Université Diderot, Paris, France
| | - Youri Yordanov
- INSERM U1153, Statistic and Epidemiologic Research Center Sorbonne Paris Cité (CRESS), METHODS Team, Hotel-Dieu Hospital, Paris, France
- Sorbonne Universités, UPMC Paris Univ-06, Paris, France
- Service des Urgences-Hôpital Saint Antoine, Assistance Publique-Hôpitaux de Paris (APHP), Paris, France
| |
Collapse
|
7
|
Kim JW, Lee KR, Hong DY, Baek KJ, Lee YH, Park SO. Efficacy of various types of laryngoscope (direct, Pentax Airway Scope and GlideScope) for endotracheal intubation in various cervical immobilisation scenarios: a randomised cross-over simulation study. BMJ Open 2016; 6:e011089. [PMID: 27797983 PMCID: PMC5093373 DOI: 10.1136/bmjopen-2016-011089] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
OBJECTIVE To compare the efficacy of direct laryngoscopy (DL), Pentax Airway Scope (PAWS) and GlideScope video laryngoscope (GVL) systems for endotracheal intubation (ETI) in various cervical immobilisation scenarios: manual in-line stabilisation (MILS), Philadelphia neck collar (PNC) (moderate limit of mouth opening) and Stifneck collar (SNC) (severe limit of mouth opening). DESIGN Randomised cross-over simulation study. SETTING AND PARTICIPANTS 35 physicians who had >30 successful ETI experiences at a tertiary hospital in Seoul, Korea. PRIMARY AND SECONDARY OUTCOME MEASURES Participants performed ETI using PAWS, GVL and DL randomly in simulated MILS, PNC and SNC scenarios in our simulation centre. The end points were successful ETI and the time to complete ETI. In addition, modified Cormack-Lehane (CL) classification and pressure to teeth were recorded. RESULTS In MILS, there were no significant differences in the rate of success of ETI between the three devices: 33/35(94.3%) for DL vs 32/35(91.4%) for GVL vs 35/35(100.0%) for PAWS; p=0.230). PAWS achieved successful ETI more quickly (19.8 s) than DL (29.6 s) and GVL (35.4 s). For the PNC scenario, a higher rate of successful ETI was achieved with GVL 33/35 (94.3%) than PAWS 29/35 (82.9%) or DL 25/35 (71.4%) (p=0.040). For the SNC scenario, a higher rate of successful ETI was achieved with GVL 28/35(80.0%) than with DL 14/35(40.0%) and PAWS 7/35(20.0%) (p<0.001). For the PNC and SNC scenarios, GVL provided a relatively good view of the glottis, but a frequent pressure to teeth occurred. CONCLUSIONS All three devices are suitable for ETI in MILS. DL is not suitable in both neck collar scenarios. PAWS showed faster intubations in MILS, but was not suitable in the SNC scenario. GVL is most suitable in all cervical immobilisation scenarios, but may cause pressure to teeth more frequently.
Collapse
Affiliation(s)
- Jong Won Kim
- Department of Emergency Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| | - Kyeong Ryong Lee
- Department of Emergency Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| | - Dae Young Hong
- Department of Emergency Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| | - Kwang Je Baek
- Department of Emergency Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| | - Young Hwan Lee
- Department of Emergency Medicine, Hallym University Sacred Heart Hospital, Hallym University, Anyang-si, Korea
| | - Sang O Park
- Department of Emergency Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| |
Collapse
|
8
|
Murphy LD, Kovacs GJ, Reardon PM, Law JA. Comparison of the King Vision Video Laryngoscope with the Macintosh Laryngoscope. J Emerg Med 2014; 47:239-46. [DOI: 10.1016/j.jemermed.2014.02.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2013] [Revised: 12/30/2013] [Accepted: 02/09/2014] [Indexed: 02/07/2023]
|