1
|
Scacciavillani R, Koliastasis L, Doundoulakis I, Chiotis S, Kordalis A, Narducci ML, Kotoulas S, Pinnacchio G, Bencardino G, Perna F, Comerci G, Gatzoulis KA, Tsiachris D, Pelargonio G. Remote Monitoring of Cardiac Implantable Electronic Devices in Very Elderly Patients: Advantages and Specific Problems. J Cardiovasc Dev Dis 2024; 11:209. [PMID: 39057629 PMCID: PMC11277150 DOI: 10.3390/jcdd11070209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 06/24/2024] [Accepted: 06/27/2024] [Indexed: 07/28/2024] Open
Abstract
Cardiac implantable electronic devices (CIEDs) offer the benefit of remote monitoring and decision making and find particular applications in special populations such as the elderly. Less transportation, reduced costs, prompt diagnosis, a sense of security, and continuous real-time monitoring are the main advantages. On the other hand, less physician-patient interactions and the technology barrier in the elderly pose specific problems in remote monitoring. CIEDs nowadays are abundant and are mostly represented by rhythm control/monitoring devices, whereas hemodynamic remote monitoring devices are gaining popularity and are evolving and becoming refined. Future directions include the involvement of artificial intelligence, yet disparities of availability, lack of follow-up data, and insufficient patient education are still areas to be improved. This review aims to describe the role of CIED in the very elderly and highlight the merits and possible drawbacks.
Collapse
Affiliation(s)
- Roberto Scacciavillani
- Department of Cardiovascular & Pulmonary Sciences, Catholic University of the Sacred Heart, 00168 Rome, Italy; (R.S.); (G.P.)
| | - Leonidas Koliastasis
- First Department of Cardiology, National and Kapodistrian University, “Hippokration” Hospital, 11527 Athens, Greece; (L.K.); (S.C.); (A.K.); (S.K.); (K.A.G.); (D.T.)
| | - Ioannis Doundoulakis
- First Department of Cardiology, National and Kapodistrian University, “Hippokration” Hospital, 11527 Athens, Greece; (L.K.); (S.C.); (A.K.); (S.K.); (K.A.G.); (D.T.)
| | - Sotirios Chiotis
- First Department of Cardiology, National and Kapodistrian University, “Hippokration” Hospital, 11527 Athens, Greece; (L.K.); (S.C.); (A.K.); (S.K.); (K.A.G.); (D.T.)
| | - Athanasios Kordalis
- First Department of Cardiology, National and Kapodistrian University, “Hippokration” Hospital, 11527 Athens, Greece; (L.K.); (S.C.); (A.K.); (S.K.); (K.A.G.); (D.T.)
| | - Maria Lucia Narducci
- Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (M.L.N.); (G.P.); (G.B.); (F.P.); (G.C.)
- Cardiology Unit, Cardiothoracic Department, Azienda Ospedaliera Universitaria Santa Maria della Misericordia, 33100 Udine, Italy
| | - Sotiris Kotoulas
- First Department of Cardiology, National and Kapodistrian University, “Hippokration” Hospital, 11527 Athens, Greece; (L.K.); (S.C.); (A.K.); (S.K.); (K.A.G.); (D.T.)
| | - Gaetano Pinnacchio
- Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (M.L.N.); (G.P.); (G.B.); (F.P.); (G.C.)
| | - Gianluigi Bencardino
- Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (M.L.N.); (G.P.); (G.B.); (F.P.); (G.C.)
| | - Francesco Perna
- Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (M.L.N.); (G.P.); (G.B.); (F.P.); (G.C.)
| | - Gianluca Comerci
- Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (M.L.N.); (G.P.); (G.B.); (F.P.); (G.C.)
| | - Konstantinos A. Gatzoulis
- First Department of Cardiology, National and Kapodistrian University, “Hippokration” Hospital, 11527 Athens, Greece; (L.K.); (S.C.); (A.K.); (S.K.); (K.A.G.); (D.T.)
| | - Dimitris Tsiachris
- First Department of Cardiology, National and Kapodistrian University, “Hippokration” Hospital, 11527 Athens, Greece; (L.K.); (S.C.); (A.K.); (S.K.); (K.A.G.); (D.T.)
| | - Gemma Pelargonio
- Department of Cardiovascular & Pulmonary Sciences, Catholic University of the Sacred Heart, 00168 Rome, Italy; (R.S.); (G.P.)
- Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy; (M.L.N.); (G.P.); (G.B.); (F.P.); (G.C.)
| |
Collapse
|
2
|
Ferrick AM, Raj SR, Deneke T, Kojodjojo P, Lopez-Cabanillas N, Abe H, Boveda S, Chew DS, Choi JI, Dagres N, Dalal AS, Dechert BE, Frazier-Mills CG, Gilbert O, Han JK, Hewit S, Kneeland C, DeEllen Mirza S, Mittal S, Ricci RP, Runte M, Sinclair S, Alkmim-Teixeira R, Vandenberk B, Varma N. 2023 HRS/EHRA/APHRS/LAHRS expert consensus statement on practical management of the remote device clinic. Heart Rhythm 2023; 20:e92-e144. [PMID: 37211145 DOI: 10.1016/j.hrthm.2023.03.1525] [Citation(s) in RCA: 38] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 03/28/2023] [Indexed: 05/23/2023]
Abstract
Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.
Collapse
Affiliation(s)
| | | | | | | | | | - Haruhiko Abe
- University of Occupational and Environmental Health Hospital, Kitakyushu, Japan
| | | | | | | | - Nikolaos Dagres
- Heart Center Leipzig at the University of Leipzig, Leipzig, Germany
| | - Aarti S Dalal
- Vanderbilt University Medical Center, Nashville, Tennessee
| | | | | | - Olivia Gilbert
- Wake Forest Baptist Medical Center, Winston-Salem, North Carolina
| | - Janet K Han
- VA Greater Los Angeles Healthcare System, Los Angeles, California
| | | | | | | | | | | | - Mary Runte
- University of Lethbridge, Lethbridge, Alberta, Canada
| | | | | | - Bert Vandenberk
- University of Calgary, Calgary, Alberta, Canada; Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | | |
Collapse
|
3
|
Varma N, Braunschweig F, Burri H, Hindricks G, Linz D, Michowitz Y, Ricci RP, Nielsen JC. Remote monitoring of cardiac implantable electronic devices and disease management. Europace 2023; 25:euad233. [PMID: 37622591 PMCID: PMC10451003 DOI: 10.1093/europace/euad233] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 06/12/2023] [Indexed: 08/26/2023] Open
Abstract
This reviews the transition of remote monitoring of patients with cardiac electronic implantable devices from curiosity to standard of care. This has been delivered by technology evolution from patient-activated remote interrogations at appointed intervals to continuous monitoring that automatically flags clinically actionable information to the clinic for review. This model has facilitated follow-up and received professional society recommendations. Additionally, continuous monitoring has provided a new level of granularity of diagnostic data enabling extension of patient management from device to disease management. This ushers in an era of digital medicine with wider applications in cardiovascular medicine.
Collapse
Affiliation(s)
- Niraj Varma
- Cardiac Pacing and Electrophysiology, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44118, USA
| | | | - Haran Burri
- University Hospital of Geneva, 1205 Geneva, Switzerland
| | | | - Dominik Linz
- Maastricht University Medical Center, 6211 LK Maastricht, The Netherlands
| | - Yoav Michowitz
- Department of Cardiology, Faculty of Medicine, Shaare Zedek Medical Center, Hebrew University, Jerusalem 9112001, Israel
| | | | | |
Collapse
|
4
|
Ferrick AM, Raj SR, Deneke T, Kojodjojo P, Lopez-Cabanillas N, Abe H, Boveda S, Chew DS, Choi JI, Dagres N, Dalal AS, Dechert BE, Frazier-Mills CG, Gilbert O, Han JK, Hewit S, Kneeland C, Mirza SD, Mittal S, Ricci RP, Runte M, Sinclair S, Alkmim-Teixeira R, Vandenberk B, Varma N, Davenport E, Freedenberg V, Glotzer TV, Huang JL, Ikeda T, Kramer DB, Lin D, Rojel-Martínez U, Stühlinger M, Varosy PD. 2023 HRS/EHRA/APHRS/LAHRS Expert Consensus Statement on Practical Management of the Remote Device Clinic. Europace 2023; 25:euad123. [PMID: 37208301 PMCID: PMC10199172 DOI: 10.1093/europace/euad123] [Citation(s) in RCA: 37] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/21/2023] Open
Abstract
Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.
Collapse
Affiliation(s)
| | | | | | | | | | - Haruhiko Abe
- University of Occupational and Environmental Health Hospital, Kitakyushu, Japan
| | | | | | | | - Nikolaos Dagres
- Heart Center Leipzig at the University of Leipzig, Leipzig, Germany
| | - Aarti S Dalal
- Vanderbilt University Medical Center, Nashville, Tennessee
| | | | | | - Olivia Gilbert
- Wake Forest Baptist Medical Center, Winston-Salem, North Carolina
| | - Janet K Han
- VA Greater Los Angeles Healthcare System, Los Angeles, California
| | | | | | | | | | | | - Mary Runte
- University of Lethbridge, Lethbridge, Alberta, Canada
| | | | | | - Bert Vandenberk
- University of Calgary, Calgary, Alberta, Canada
- Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Vandenberk B, Raj SR. Remote Patient Monitoring: What Have We Learned and Where Are We Going? CURRENT CARDIOVASCULAR RISK REPORTS 2023; 17:103-115. [PMID: 37305214 PMCID: PMC10122094 DOI: 10.1007/s12170-023-00720-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/28/2023] [Indexed: 06/13/2023]
Abstract
Purpose of Review Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) is an important part of patient follow-up. The increasing number of patients with CIEDs and the recent pandemic pose several challenges for already limited device clinic resources. This review focuses on recent evolutions in RM and identifies future needs to improve RM. Recent Findings RM has been associated with multiple clinical benefits, including improved survival, early detection of actionable events, reduction in inappropriate shocks, longer battery lives, and more efficient healthcare utilization. The survival benefit was driven by studies using alert-based continuous RM with daily transmissions and fast reaction times. Patients report a high satisfaction rate without significant differences in quality of life between RM and in-office follow-up.The increasing workload, due to the increasing number of CIEDs implanted with daily remote transmissions, results in several challenges for the future of RM. RM requires appropriate reimbursement for RM device clinics to optimize patient/staff ratios, including sufficient non-clinical and administrative support. Universal alert programming and data processing may minimize inter-manufacturer differences, improve the signal-to-noise ratio, and allow the development of standard operating protocols and workflows. In the future, programming by remote control and true remote programming may further improve remote CIED management, patient quality of life, and device clinic workflows. Summary RM should be considered standard of care in management of patients with CIEDs. The clinical benefits of RM can be maximized by an alert-based continuous RM model. Adapted healthcare policies are required to keep RM manageable for the future.
Collapse
Affiliation(s)
- Bert Vandenberk
- Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Satish R. Raj
- Department of Cardiac Sciences, Cumming School of Medicine, Libin Cardiovascular Institute, University of Calgary, GAC70 HRIC Building, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6 Canada
- Autonomic Dysfunction Center, Division of Clinical Pharmacology, Department of Medicine, Vanderbilt University Medical Center, Nashville, TN USA
| |
Collapse
|
6
|
Stegemann E, Weidmann M, Miyazawa AA, Shun-Shin MJ, Leyva F, Zegard A, Stegemann B. Laser Doppler flow for the hemodynamic differentiation of tachycardia. Pacing Clin Electrophysiol 2023; 46:114-124. [PMID: 36385259 DOI: 10.1111/pace.14618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 09/15/2022] [Accepted: 10/31/2022] [Indexed: 11/18/2022]
Abstract
BACKGROUND Implantable cardioverter defibrillators (ICDs) offer effective therapy for the prevention of sudden cardiac death (SCD) due to ventricular arrhythmias. However, inappropriate shocks have detrimental effects on survival and quality of life. The addition of hemodynamic monitoring may be useful in discriminating clinically important ventricular arrhythmias. OBJECTIVE In this study, we assess the ability of laser Doppler flowmetry to assess the hemodynamic effect of paced atrial and ventricular arrhythmias using mean arterial blood pressure as the reference. METHODS In this acute human study in patients undergoing an elective electrophysiological study, laser Doppler flowmetry, arterial blood pressure, and surface ECG were acquired during high-rate atrial and ventricular pacing to simulate supraventricular and ventricular tachycardias. RESULTS Arterial blood pressure and laser Doppler flow signals correlated well during atrial and ventricular pacing (rho = 0.694, p < .001). The hemodynamic impairment detected by both methods was greater during ventricular pacing than atrial pacing (-1.0% vs. 19.0%, p < .001). Laser Doppler flowmetry performed better than rate alone to identify hemodynamic impairments. CONCLUSION In this acute study, laser Doppler flowmetry tissue perfusion served as a good surrogate measure for arterial pressure, which could be incorporated into future ICDs.
Collapse
Affiliation(s)
- Emilia Stegemann
- Clinic for Internal Medicine & Angiology, Agaplesion Diakonie Kliniken Kassel, Kassel, Germany
- Klinik für Kardiologie und Angiologie, Medizinische Fakultät der Philipps-Universität Marburg, Marburg, Germany
| | - Mia Weidmann
- Medizinische Klinik II, Klinikum Kassel, Kassel, Germany
| | - Alejandra A Miyazawa
- National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom
| | - Matthew J Shun-Shin
- National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom
| | - Francisco Leyva
- Aston Medical School, Aston University, Birmingham, United Kingdom
- Queen Elizabeth Hospital, Birmingham, United Kingdom
| | - Abbasin Zegard
- Aston Medical School, Aston University, Birmingham, United Kingdom
- Queen Elizabeth Hospital, Birmingham, United Kingdom
| | - Berthold Stegemann
- National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom
- Aston Medical School, Aston University, Birmingham, United Kingdom
- Queen Elizabeth Hospital, Birmingham, United Kingdom
| |
Collapse
|
7
|
McGee MJ, Ray M, Brienesse SC, Sritharan S, Boyle AJ, Jackson N, Leitch JW, Sverdlov AL. Remote monitoring in patients with heart failure with cardiac implantable electronic devices: a systematic review and meta-analysis. Open Heart 2022; 9:openhrt-2022-002096. [PMID: 36442906 PMCID: PMC9710367 DOI: 10.1136/openhrt-2022-002096] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 11/08/2022] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) is now the standard of care, but whether the demonstrated benefits of RM translate into improvements in heart failure (HF) management is controversial. This systematic review addresses the role of RM in patients with HF with a CIED. METHODS AND RESULTS A systematic search of the literature for randomised clinical trials in patients with HF and a CIED assessing efficacy/effectiveness of RM was performed using MEDLINE, PubMed and Embase. Meta-analysis was performed on the effects of RM of CIEDs in patients with HF on mortality and readmissions. Effects on implantable cardiac defibrillator (ICD) therapy, healthcare costs and clinic presentations were also assessed.607 articles were identified and refined to 10 studies with a total of 6579 patients. Implementation of RM was not uniform with substantial variation in methodology across the studies. There was no reduction in mortality or hospital readmission rates, while ICD therapy findings were inconsistent. There was a reduction in patient-associated healthcare costs and reduction in healthcare presentations. CONCLUSION RM for patients with CIEDs and HF was not uniformly performed. As currently implemented, RM does not provide a benefit on overall mortality or the key metric of HF readmission. It does provide a reduction in healthcare costs and healthcare presentations. PROSPERO REGISTRATION NUMBER CRD42019129270.
Collapse
Affiliation(s)
- Michael J McGee
- Department of Cardiology, Tamworth Rural Referral Hospital, Tamworth, New South Wales, Australia,Department of Cardiology, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
| | - Max Ray
- Department of Cardiology, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
| | - Stepehn C Brienesse
- Department of Cardiology, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
| | - Shanathan Sritharan
- Department of Cardiology, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
| | - Andrew J Boyle
- Department of Cardiology, John Hunter Hospital, New Lambton Heights, New South Wales, Australia,Hunter Medical Research Institute, Faculty of Health and Medicine, The University of Newcastle, Callaghan, New South Wales, Australia
| | - Nicholas Jackson
- Department of Cardiology, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
| | - James W Leitch
- Department of Cardiology, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
| | - Aaron L Sverdlov
- Department of Cardiology, John Hunter Hospital, New Lambton Heights, New South Wales, Australia,Hunter Medical Research Institute, Faculty of Health and Medicine, The University of Newcastle, Callaghan, New South Wales, Australia
| |
Collapse
|
8
|
Götz TF, Proff J, Timmel T, Jilek C, Tiemann K, Lewalter T. Potential of remote monitoring to prevent sensing and detection failures in implantable cardioverter defibrillators. Herzschrittmacherther Elektrophysiol 2021; 33:63-70. [PMID: 34468842 DOI: 10.1007/s00399-021-00802-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Accepted: 07/29/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Sensing malfunction and misinterpretation of intracardiac electrograms (IEGMs) in patients with implantable cardioverter defibrillators (ICDs) may lead to inadequate device activity such as inappropriate shock delivery or unnecessary mode-switching. Remote monitoring has the potential for early detection of sensing malfunction or misclassification and may thus prevent adverse device activity. Therefore, the authors analyzed the amount, nature, and distribution of misclassification in current ICD and cardiac resynchronization therapy defibrillator technology using the device transmissions of the IN-TIME study population. METHODS All transmitted tachyarrhythmic episodes in the 664 IN-TIME patients, comprising 2214 device-classified atrial fibrillation (DC-AF) episodes lasting ≥ 30 s and 1330 device-classified ventricular tachycardia or fibrillation (DC-VT/VF) episodes, were manually analyzed by two experienced cardiologists. RESULTS After evaluation of all DC-VT/VF episodes, a total of 300 VT/VF events (23.1%) were false-positive, with supraventricular tachycardia being the most frequent cause (51.7%), followed by atrial fibrillation (21.3%) and T‑wave oversensing (21.0%). A total of 15 patients with false-positive DC-VT/VF received inappropriate shocks. According to the inclusion criteria, 616 IEGMs with DC-AF were assessed. A total of 19.7% were false-positive AF episodes and R‑wave oversensing was the most common reason (55.9%). CONCLUSIONS Remote monitoring offers the opportunity of early detection of signal misclassification and thus early prevention of adverse device reaction, such as inappropriate shock delivery or mode-switching with intermittent loss of atrioventricular synchrony, by correcting the underlying causes.
Collapse
Affiliation(s)
- Tobias Franz Götz
- Klinik für Kardiologie und Internistische Intensivmedizin, Peter Osypka Herzzentrum, Internistisches Klinikum München Süd GmbH, Am Isarkanal 36, 81379, München, Germany. .,Klinik für Kardiologie, Universitätsklinikum Bonn, Bonn, Germany.
| | | | | | - Clemens Jilek
- Klinik für Kardiologie und Internistische Intensivmedizin, Peter Osypka Herzzentrum, Internistisches Klinikum München Süd GmbH, Am Isarkanal 36, 81379, München, Germany
| | - Klaus Tiemann
- Klinik für Kardiologie und Internistische Intensivmedizin, Peter Osypka Herzzentrum, Internistisches Klinikum München Süd GmbH, Am Isarkanal 36, 81379, München, Germany.,I. Medizinische Klinik, Klinikum rechts der Isar, Technische Universität München, München, Germany
| | - Thorsten Lewalter
- Klinik für Kardiologie und Internistische Intensivmedizin, Peter Osypka Herzzentrum, Internistisches Klinikum München Süd GmbH, Am Isarkanal 36, 81379, München, Germany.,Klinik für Kardiologie, Universitätsklinikum Bonn, Bonn, Germany
| |
Collapse
|
9
|
Kurita T, Ando K, Ueda M, Shizuta S, Okamura H, Matsumoto N, Gerritse B, Fagan DH, Schloss EJ, Meijer A, Auricchio A, Sterns LD, Okumura K. Comparison of ICD shock rates in Japanese and non-Japanese patients in the PainFree SST study. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2018; 41:1185-1191. [DOI: 10.1111/pace.13427] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Revised: 05/23/2018] [Accepted: 06/11/2018] [Indexed: 02/04/2023]
Affiliation(s)
- Takashi Kurita
- Cardiology; Kindai University School of Medicine; Osaka Japan
| | - Kenji Ando
- Department of Cardiology; Kokura Memorial Hospital; Fukuoka Japan
| | - Marehiko Ueda
- Department of Cardiology; Eastern Chiba Medical Center; Chiba Japan
| | - Satoshi Shizuta
- Department of Cardiovascular Medicine; Kyoto University Graduate School of Medicine; Kyoto Japan
| | - Hideo Okamura
- Department of Cardiovascular Medicine; National Hospital Organization Wakayama Hospital; Wakayama Japan
| | - Naoki Matsumoto
- Pharmacology; St. Marianna University School of Medicine; Kanagawa Japan
| | - Bart Gerritse
- Medtronic Bakken Research Center; Maastricht Netherlands
| | | | | | | | | | | | - Ken Okumura
- Division of Cardiology; Saiseikai Kumamoto Hospital Cardiovascular Center; Kumamoto Japan
| | | |
Collapse
|
10
|
Cardoso RN, Healy C, Viles-Gonzalez J, Coffey JO. ICD discrimination of SVT versus VT with 1:1 V-A conduction: A review of the literature. Indian Pacing Electrophysiol J 2016; 15:236-44. [PMID: 27134440 PMCID: PMC4834441 DOI: 10.1016/j.ipej.2016.02.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Inappropriate ICD shocks are associated with increased mortality. They also impair patients' quality of life, increase hospitalizations, and raise health-care costs. Nearly 80% of inappropriate ICD shocks are caused by supraventricular tachycardia. Here we report the case of a patient who received a single-lead dual-chamber sensing ICD for primary prevention of sudden cardiac death and experienced inappropriate ICD shocks. V-A time, electrogram morphology, and response to antitachycardia pacing suggested atrioventricular nodal reentry tachycardia, which was confirmed in an electrophysiology study. Inspired by this case, we performed a literature review to discuss mechanisms for discrimination of supraventricular tachycardia with 1:1 A:V relationship from ventricular tachycardia with 1:1 retrograde conduction.
Collapse
Affiliation(s)
- Rhanderson N Cardoso
- Cardiovascular Division, Department of Medicine, University of Miami, Miller School of Medicine, Miami, USA
| | - Chris Healy
- Cardiovascular Division, Department of Medicine, University of Miami, Miller School of Medicine, Miami, USA
| | - Juan Viles-Gonzalez
- Cardiovascular Division, Department of Medicine, University of Miami, Miller School of Medicine, Miami, USA
| | - James O Coffey
- Cardiovascular Division, Department of Medicine, University of Miami, Miller School of Medicine, Miami, USA
| |
Collapse
|
11
|
Lunati M, Proclemer A, Boriani G, Landolina M, Locati E, Rordorf R, Daleffe E, Ricci RP, Catanzariti D, Tomasi L, Gulizia M, Baccillieri MS, Molon G, Gasparini M. Reduction of inappropriate anti-tachycardia pacing therapies and shocks by a novel suite of detection algorithms in heart failure patients with cardiac resynchronization therapy defibrillators: a historical comparison of a prospective database. Europace 2016; 18:1391-8. [PMID: 26826135 DOI: 10.1093/europace/euv420] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Accepted: 11/18/2015] [Indexed: 11/14/2022] Open
Abstract
AIMS Implantable cardioverter defibrillators improve survival of patients at risk for ventricular arrhythmias, but inappropriate shocks occur in up to 30% of patients and have been associated with worse quality of life and prognosis. In heart failure patients with cardiac resynchronization therapy defibrillators (CRT-Ds), we evaluated whether a new generation of detection and discrimination algorithms reduces inappropriate shocks. METHODS AND RESULTS We analysed 1983 Medtronic CRT-D patients (80% male, 67 ± 10 years), 1368 with standard devices (Control CRT-D) and 615 with new generation devices (New CRT-D). Expert electrophysiologists reviewed and classified the electrograms of all device-detected ventricular tachycardia/fibrillation episodes. Total follow-up was 3751 patients-years. Incidence of inappropriate shocks at 1 year was 2.8% [95% confidence interval (CI) = 2.0-3.5] in Control CRT-D and 0.9% (CI = 0.4-2.2) in New CRT-D (hazard ratio = 0.37, CI = 0.21-0.66, P < 0.001). In New CRT-D, inappropriate shocks were reduced by 77% [incidence rate ratio (IRR) = 0.23, CI = 0.16-0.35, P < 0.001] and inappropriate anti-tachycardia pacing by 81% (IRR = 0.19, CI = 0.11-0.335, P < 0.001). Annual rate per 100 patient-years for appropriate VF detections was 3.0 (CI = 2.1-4.2) in New CRT-D and 3.2 (CI = 2.1-5.0) in Control CRT-D (P = 0.68), for syncope was 0.4 (CI = 0.2-0.9) in New CRT-D and 0.7 (CI = 0.5-1.0) in Control CRT-D (P = 0.266), and for death was 1.0 (CI = 0.6-1.6) in New CRT-D and 3.5 (CI = 3.0-4.1) in Control CRT-D (P < 0.001). CONCLUSION Detection and discrimination algorithms used in new generation CRT-D significantly reduced inappropriate shocks when compared with standard CRT-D. This result, with no compromise on VF sensitivity or risk of syncope, has important implications for patients' quality of life and prognosis.
Collapse
Affiliation(s)
- Maurizio Lunati
- 'A De Gasperis' Cardiac Department, Niguarda Ca' Granda Hospital, Piazza Ospedale Maggiore, 3, 20162 Milano, Italy
| | | | - Giuseppe Boriani
- University of Bologna and Azienda Ospedaliera S.Orsola-Malpighi, Bologna, Italy
| | - Maurizio Landolina
- Fondazione Policlinico S. Matteo IRCCS, Pavia, Italy Ospedale Maggiore, Crema (Cremona), Italy
| | - Emanuela Locati
- 'A De Gasperis' Cardiac Department, Niguarda Ca' Granda Hospital, Piazza Ospedale Maggiore, 3, 20162 Milano, Italy
| | | | | | | | | | - Luca Tomasi
- Azienda Ospedaliera Universitaria Integrata, Verona, Italy
| | | | | | - Giulio Molon
- Ospedale Sacro Cuore Don Calabria, Negrar, Italy
| | | | | |
Collapse
|
12
|
Jawad-Ul-Qamar M, Kirchhof P. Almanac 2015: atrial fibrillation research in Heart. Heart 2016; 102:573-80. [PMID: 26791994 PMCID: PMC4819630 DOI: 10.1136/heartjnl-2015-307809] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 11/26/2015] [Indexed: 01/21/2023] Open
Abstract
Atrial fibrillation continues to attract interest in the cardiovascular community and in Heart. Over 60 original research and review papers published in Heart in 2014–2015 cover various aspects of atrial fibrillation, from associated conditions and precipitating factors to new approaches to management. Here, we provide an overview of articles on atrial fibrillation published in Heart in 2014–2015, highlighting new developments, emerging concepts and novel approaches to treatment.
Collapse
Affiliation(s)
- Muhammad Jawad-Ul-Qamar
- Institute of Cardiovascular Sciences, University of Birmingham, Birmingham, UK SWBH NHS Trust, Birmingham, UK
| | - Paulus Kirchhof
- Institute of Cardiovascular Sciences, University of Birmingham, Birmingham, UK SWBH NHS Trust, Birmingham, UK UHB NHS Trust, Birmingham, UK Atrial Fibrillation NETwork (AFNET), Münster, Germany Department of Cardiovascular Medicine, Hospital of the University of Münster, Münster, Germany
| |
Collapse
|
13
|
Barold SS, Herweg B. Cardiac Resynchronization in Patients with Atrial Fibrillation. J Atr Fibrillation 2015; 8:1383. [PMID: 27957235 DOI: 10.4022/jafib.1383] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 12/19/2015] [Accepted: 12/24/2015] [Indexed: 12/19/2022]
Abstract
Atrial fibrillation (AF) occurs in one of four patients undergoing cardiac resynchronization therapy (CRT).-Without special therapy, the prognosis of AF patients with CRT has been generally worse than those in sinus rhythm. The importance of a high percentage of biventricular pacing (BIV%) was confirmed in a large study where the mortality was inversely associated with BIV% both in the presence of normal sinus and atrial paced rhythm and with AF. The greatest reduction in mortality was observed with BIV% >98%. Patients with BIV% >99.6% experienced a 24% reduction in mortality (p < 0.001) while those with BIV% <94.8% had a 19% increase in mortality. The optimal BIV% cut-point was 98.7%. This cutoff would appear mandatory but it would be best to approach 100%. Careful evaluation of device interrogation data upon which the BiV% is based is essential because the memorized data can vastly overestimate the percentage of truly resynchronized beats since it does not account for fusion and pseudofusion between intrinsic (not paced) and paced beats. The recently published randomized CERTIFY trial provides unequivocal proof of the value of AV junctional (AVJ) ablation in CRT patients with AF. This trial confirmed the favorable results of AVJ ablation by many other studies and two important meta-analyses and therefore established the firm recommendation that the procedure should be performed in most, if not all, patients with permanent AF as well as those with frequent and prolonged episodes of paroxysmal AF. Patients after AVJ have improved mortality with a mortality similar to those in sinus rhythm. The AVJ ablation procedure carries the theoretical risk of device failure and death in pacemaker dependent patients. An inappropriate first ICD shock for AF seems to increase mortality. Increased long-term mortality after an inappropriate shock may be due to the underlying atrial arrhythmia substrate as opposed to the effect of the shock itself.
Collapse
Affiliation(s)
- S Serge Barold
- Clinical Professor of Medicine Emeritus, Department of Medicine, University of Rochester School of Medicine and Dentistry, Rochester, New York
| | - Bengt Herweg
- Professor of Medicine and Director of the Arrhythmia Service, University of South Florida College of Medicine and Tampa General Hospital, Tampa, Florida
| |
Collapse
|
14
|
HRS Expert Consensus Statement on remote interrogation and monitoring for cardiovascular implantable electronic devices. Heart Rhythm 2015; 12:e69-100. [PMID: 25981148 DOI: 10.1016/j.hrthm.2015.05.008] [Citation(s) in RCA: 376] [Impact Index Per Article: 37.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Indexed: 11/23/2022]
|