1
|
Comparative clinical performance of two types of drug-eluting stents with abluminal biodegradable polymer coating: Five-year results of the DESTINY randomized trial. REVISTA PORTUGUESA DE CARDIOLOGIA (ENGLISH EDITION) 2021. [DOI: 10.1016/j.repce.2020.05.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
2
|
Prado GFA, Abizaid AAC, Meireles GC, Sarmento-Leite R, Prudente M, Cantarelli M, Dourado AD, Jr JM, Perin MA, Costantini C, Costa R, Costa JR, Chamie D, Campos CM, Ribeiro EE, Lemos PA. Comparative clinical performance of two types of drug-eluting stents with abluminal biodegradable polymer coating: Five-year results of the DESTINY randomized trial. Rev Port Cardiol 2021; 40:71-76. [PMID: 33402278 DOI: 10.1016/j.repc.2020.05.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 02/18/2020] [Accepted: 05/05/2020] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION AND OBJECTIVES The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron™ sirolimus-eluting stent (SES) with the control Biomatrix™ Flex biolimus-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure. METHODS A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization. RESULTS At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group. CONCLUSIONS The novel Inspiron™ stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix™ Flex biolimus-eluting stent.
Collapse
Affiliation(s)
- Guy F A Prado
- Heart Institute (InCor), University of São Paulo Medical School, São Paulo, SP, Brazil; Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
| | | | - George C Meireles
- Hospital do Servidor Público Estadual - IAMSPE, São Paulo, SP, Brazil
| | - Rogério Sarmento-Leite
- Institute of Cardiology/Fundação Universitária de Cardiologia de Porto Alegre, Porto Alegre, RS, Brazil
| | | | | | | | - Jose Mariani Jr
- Heart Institute (InCor), University of São Paulo Medical School, São Paulo, SP, Brazil; Hospital Israelita Albert Einstein, São Paulo, SP, Brazil; Faculdade de Ciências Médicas da Santa Casa de São Paulo, São Paulo, SP, Brazil
| | | | | | - Ricardo Costa
- Instituto Dante Pazzanese de Cardiologia, São Paulo, SP, Brazil
| | - J Ribamar Costa
- Instituto Dante Pazzanese de Cardiologia, São Paulo, SP, Brazil
| | - Daniel Chamie
- Instituto Dante Pazzanese de Cardiologia, São Paulo, SP, Brazil
| | - Carlos M Campos
- Heart Institute (InCor), University of São Paulo Medical School, São Paulo, SP, Brazil; Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
| | - Expedito E Ribeiro
- Heart Institute (InCor), University of São Paulo Medical School, São Paulo, SP, Brazil
| | - Pedro A Lemos
- Heart Institute (InCor), University of São Paulo Medical School, São Paulo, SP, Brazil; Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
| |
Collapse
|
3
|
Five-Year Results of the Bioflow-III Registry: Real-World Experience with a Biodegradable Polymer Sirolimus-Eluting Stent. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2020; 21:63-69. [DOI: 10.1016/j.carrev.2019.03.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 02/18/2019] [Accepted: 03/06/2019] [Indexed: 11/21/2022]
|
4
|
Lefèvre T, Haude M, Neumann FJ, Stangl K, Skurk C, Slagboom T, Sabaté M, Goicolea J, Barragan P, Cook S, Macia JC, Windecker S. Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent: 5-Year Outcomes of the Randomized BIOFLOW-II Trial. JACC Cardiovasc Interv 2019; 11:995-1002. [PMID: 29798778 DOI: 10.1016/j.jcin.2018.04.014] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 03/12/2018] [Accepted: 04/10/2018] [Indexed: 12/12/2022]
Abstract
OBJECTIVES The authors aimed to compare long-term data of an ultrathin cobalt-chromium stent with passive silicon carbide coating and an active biodegradable polymer that releases sirolimus (O-SES) (Orsiro, BIOTRONIK, Bülach, Switzerland) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) (Abbott Vascular, Santa Clara, California). BACKGROUND Biodegradable polymer stents have been developed aiming to overcome long-term detrimental effects of durable polymer stents, ultimately leaving a bare-metal stent in the vessel. METHODS This multicenter, assessor-blinded trial randomized 452 patients with 505 lesions to either O-SES or X-EES in a 2:1 fashion. Endpoints at 5 years were target lesion failure (TLF), its components, and stent thrombosis. RESULTS TLF occurred in 10.4% (n = 30) of O-SES patients versus 12.7% (n = 19) of X-EES patients (p = 0.473), overall stent thrombosis occurred in 0.7% (n = 2) versus 2.8% (n = 4) (p = 0.088), and definite stent thrombosis in 0% versus 0.7% (n = 1) (p = 0.341). Post hoc analysis was performed in diabetic patients (n = 128) and vessels ≤2.75 mm (n = 259). In diabetic patients, the O-SES group had numerically more target lesion revascularizations (13.5% vs. 4.5%; p = 0.138), but fewer cardiac deaths (1.3% vs. 6.9%; p = 0.089) and stent thrombosis (0% vs. 6.9%; p = 0.039). In small vessels, the O-SES group had a significantly lower 5-year mortality (3.7% vs. 11.3%; p = 0.022). CONCLUSIONS At 5 years, the biodegradable polymer O-SES demonstrated low TLF rates comparable to the durable polymer X-EES, confirming its long-term safety and performance. Particularly encouraging is the absence of definite stent thrombosis.
Collapse
Affiliation(s)
- Thierry Lefèvre
- Department of Interventional Cardiology, Hopital Jacques Cartier, Massy, France.
| | - Michael Haude
- Medical Clinic I, Städtische Kliniken Neuss, Lukaskrankenhaus, Neuss, Germany
| | - Franz-Josef Neumann
- Department of Cardiology and Angiology, Universitäts-Herzzentrum Freiburg-Bad Krozingen, Bad Krozingen, Germany
| | - Karl Stangl
- Department of Cardiology, Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Carsten Skurk
- Department of Cardiology, Charité Campus Benjamin Franklin, Berlin, Germany
| | - Ton Slagboom
- Department of Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, the Netherlands
| | - Manel Sabaté
- Department of Cardiology, Hospital Clínic, Thorax Institute, Barcelona, IDIBAPS, University of Barcelona, Barcelona, Spain
| | - Javier Goicolea
- Department of Cardiology, Hospital Puerta de Hierro, Madrid, Spain
| | - Paul Barragan
- Department of Cardiology, Polyclinique les Fleurs, Ollioules, France
| | - Stéphane Cook
- Department of Cardiology, Hospital and University Fribourg, Switzerland
| | | | - Stephan Windecker
- Department of Cardiology, Bern University Hospital, Bern, Switzerland
| |
Collapse
|
5
|
Kobo O, Roguin A. Orsiro: ultrathin bioabsorbable polymer sirolimus-eluting stent. Future Cardiol 2019; 15:295-300. [DOI: 10.2217/fca-2019-0001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Recent stent developments aimed to reduce and eliminate the long-term inflammatory response include thinner struts, modifications to stent design and the development of bioresorbable polymers (BP). We aimed to summarize the main findings and to discuss the established and the potential benefits of the Orsiro BP sirolimus-eluting stents in everyday clinical use. We have reviewed the available evidence on the clinical performance of the Orsiro BP drug-eluting stents. Orsiro BP sirolimus-eluting stents is clinically proven and showed noninferiority against major drug-eluting stents and provides high safety and efficacy profile at long-term follow-up. Furthermore, it may be the preferred treatment option in specific subgroups as acute coronary syndrome, as shown in the BIOFLOW V trial.
Collapse
Affiliation(s)
- Ofer Kobo
- Hillel Yaffe Medical Center, Hadera, Faculty of Medicine – Technion Israel Institute of Technology, Israel
| | - Ariel Roguin
- Hillel Yaffe Medical Center, Hadera, Faculty of Medicine – Technion Israel Institute of Technology, Israel
| |
Collapse
|
6
|
Nogic J, McCormick LM, Francis R, Nerlekar N, Jaworski C, West NE, Brown AJ. Novel bioabsorbable polymer and polymer-free metallic drug-eluting stents. J Cardiol 2018; 71:435-443. [DOI: 10.1016/j.jjcc.2017.12.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Revised: 11/16/2017] [Accepted: 12/04/2017] [Indexed: 01/07/2023]
|
7
|
Stent thrombosis rates the first year and beyond with new- and old-generation drug-eluting stents compared to bare metal stents. Clin Res Cardiol 2018; 107:816-823. [PMID: 29667015 PMCID: PMC6105307 DOI: 10.1007/s00392-018-1252-0] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Accepted: 04/09/2018] [Indexed: 12/11/2022]
Abstract
Objectives Old-generation drug-eluting coronary stents (o-DES) have despite being safe and effective been associated with an increased propensity of late stent thrombosis (ST). We evaluated ST rates in o-DES, new-generation DES (n-DES) and bare metal stents (BMS) the first year (< 1 year) and beyond 1 year (> 1 year). Methods We evaluated all implantations with BMS, o-DES (Cordis Cypher, Boston Scientific Taxus Liberté and Medtronic Endeavor) and n-DES in the Swedish coronary angiography and angioplasty registry (SCAAR) between 1 January 2007 and 8 January 2014 (n = 207 291). All cases of ST (n = 2 268) until 31 December 2014 were analyzed. Results The overall risk of ST was lower in both n-DES and o-DES compared with BMS up to 1 year (n-DES versus BMS: adjusted risk ratio (RR) 0.48 (0.41–0.58) and o-DES versus BMS: 0.56 (0.46–0.67), both p < 0.001). From 1 year after stent implantation and onward, the risk for ST was higher in o-DES compared with BMS [adjusted RR, 1.82 (1.47–2.25], p < 0.001). N-DES were associated with similar low ST rates as BMS from 1 year and onward [adjusted RR 1.21 (0.94–1.56), p = 0.135]. Conclusion New-generation DES were associated with lower ST rates in comparison to BMS during the first-year post-stenting. After 1 year, n-DES and BMS were associated with similar ST rates. Trial Registration This study was a retrospective observational study and as such did not require clinical trial database registration. Electronic supplementary material The online version of this article (10.1007/s00392-018-1252-0) contains supplementary material, which is available to authorized users.
Collapse
|
8
|
Ohya M, Kubo S, Kuwayama A, Miura K, Shimada T, Amano H, Hyodo Y, Otsuru S, Habara S, Tada T, Tanaka H, Fuku Y, Katoh H, Goto T, Kadota K. Long-term (8-10 years) outcomes after biodegradable polymer-coated biolimus-eluting stent implantation. Heart 2017; 103:1002-1008. [PMID: 28096181 DOI: 10.1136/heartjnl-2016-310591] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 12/09/2016] [Accepted: 12/19/2016] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVE Efficacy and safety data on biodegradable polymer-coated biolimus-eluting stent (BP-BES) are currently limited to 5 years. We evaluated longer term (8-10 years) clinical and angiographic outcomes after BP-BES implantation. METHODS Between 2005 and 2008, 243 patients (301 lesions) underwent BP-BES implantation. The primary clinical outcome measure was defined as any target lesion revascularisation (TLR). Absolute serial angiographic studies without any concomitant TLR within 2 years after the procedure were performed in 55 patients (65 lesions) at postprocedure, mid-term (within 1 year), late term (between 1 and 2 years) and very late term (beyond 2 years). RESULTS The median follow-up duration was 9.4 years (IQR 8.2-10.2 years). The 8-year cumulative incidence of any TLR was 20.3%. The increase rate was approximately 7% per year in the first 2 years, but decelerated to approximately 1.2% per year beyond 2 years after the procedure. The minimal lumen diameter significantly decreased from postprocedure (2.63±0.44 mm) to mid-term (2.43±0.59 mm, p=0.002) and from late term (2.27±0.63 mm) to very late term (1.98±0.73 mm, p=0.002). The 8-year cumulative incidences of definite or probable stent thrombosis (ST) and major bleeding (Bleeding Academic Research Consortium (BARC) ≥3) were 0.5% and 12.0%, respectively. Definite ST was none within 10 years in the entire cohort. CONCLUSIONS The long-term clinical outcomes after BP-BES implantation were favourable, although angiographic late progression of luminal narrowing did not reach a plateau. The incidence of ST remained notably low, whereas that of major bleeding gradually increased.
Collapse
Affiliation(s)
- Masanobu Ohya
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Shunsuke Kubo
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Akimune Kuwayama
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Katsuya Miura
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Takenobu Shimada
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Hidewo Amano
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Yusuke Hyodo
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Suguru Otsuru
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Seiji Habara
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Takeshi Tada
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Hiroyuki Tanaka
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Yasushi Fuku
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Harumi Katoh
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Tsuyoshi Goto
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| | - Kazushige Kadota
- Department of Cardiology, Kurashiki Central Hospital, Kurashiki, Okayama, Japan
| |
Collapse
|
9
|
Affiliation(s)
- Salvatore Cassese
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
| | - Erion Xhepa
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
| | - Adnan Kastrati
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany.,DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany
| |
Collapse
|