1
|
Electrocardiographic and echocardiographic dyssynchrony parameters that might better predict the response to cardiac resynchronization therapy than QRS morphology and duration. J Geriatr Cardiol 2022; 19:98-100. [PMID: 35317395 PMCID: PMC8915425 DOI: 10.11909/j.issn.1671-5411.2022.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
2
|
Vacarescu C, Cozma D, Petrescu L, Dragan S, Mornos C, Crisan S, Feier H, Lazar MA, Cozlac RA, Luca CT. Exercise test is essential in LV-only fusion CRT pacing without right ventricle lead. Clin Interv Aging 2019; 14:969-975. [PMID: 31239651 PMCID: PMC6556564 DOI: 10.2147/cia.s206251] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Accepted: 04/20/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose: Left ventricle (LV)-only pacing is non-inferior to biventricular pacing but permanent fusion pacing is needed to ensure cardiac resynchronization therapy (CRT) responsiveness. The role of systematic exercise testing (ET) in these patients has not been established. This study was designed to assess clinical and therapeutic implications (device programming/drugs) of systematic ET in patients requiring fusion-pacing CRT without an right ventricle (RV) lead. Methods: Consecutive patients with a right atrium/LV-only dual-chamber (DDD) pacing system were included. Prospective data were obtained: device interrogation, ET, and echocardiography at every 6-month follow-up visit. CRT assessment during ET included maximal heart rate, beat-to-beat echocardiography analysis of LV fusion pacing, LV loss of capture, and improvement in exercise capacity. If LV loss of capture or unsatisfactory LV fusion pacing occurred, reprogramming was individualized for each patient and ET redone. Results: A total of 55 patients (29 male) aged 62±11 years were included. During follow-up (39±18 months), a total of 235 ETs were performed, with mean exercise load 6.4±1.3 metabolic equivalents of task (118±35 W, maximal heart rate 119±17 beats/min). Twenty patients (36%) had inadequate pacing or loss of LV capture during ET, due to exceeding the maximum tracking rate (11%), chronotropic incompetence (7%), and LV pacing outside the fusion-pacing band (18%), caused by physiological shortening of the PR interval or exagerated LV preexcitation during maximum exercise. Post-ET CRT-device optimization included reprogramming of rate-adaptive atrioventricular interval (total decrease 23±8 ms), individualized programming of maximum tracking rate, or rate-response function. Drug optimization was performed in 32% of patients, and ET redone in 36%. Conclusion: In one of three ETs, an intervention in device and medication optimization was done to ensure a better outcome. Routine ET should be a standard approach to maximize fusion-pacing CRT response during follow-up.
Collapse
Affiliation(s)
- Cristina Vacarescu
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
| | - Dragos Cozma
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
- Cardiology Department, Institute of Cardiovascular Diseases, Timișoara, Romania
| | - Lucian Petrescu
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
- Cardiology Department, Institute of Cardiovascular Diseases, Timișoara, Romania
| | - Simona Dragan
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
- Cardiology Department, Institute of Cardiovascular Diseases, Timișoara, Romania
| | - Cristian Mornos
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
- Cardiology Department, Institute of Cardiovascular Diseases, Timișoara, Romania
| | - Simina Crisan
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
- Cardiology Department, Institute of Cardiovascular Diseases, Timișoara, Romania
| | - Horea Feier
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
- Cardiology Department, Institute of Cardiovascular Diseases, Timișoara, Romania
| | - Mihai-Andrei Lazar
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
| | - Ramona Alina Cozlac
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
- Cardiology Department, Institute of Cardiovascular Diseases, Timișoara, Romania
| | - Constantin Tudor Luca
- Cardiology Department, Victor Babeș University of Medicine and Pharmacy, Timișoara, Romania
- Cardiology Department, Institute of Cardiovascular Diseases, Timișoara, Romania
| |
Collapse
|
3
|
Otto CM. Heartbeat: Causes and consequences of atrial fibrillation. BRITISH HEART JOURNAL 2018; 104:1229-1231. [DOI: 10.1136/heartjnl-2018-313764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|