1
|
Liao J, Misaki K, Sakamoto J. Impact Exploration of Spatiotemporal Feature Derivation and Selection on Machine Learning-Based Predictive Models for Post-Embolization Cerebral Aneurysm Recanalization. Cardiovasc Eng Technol 2024:10.1007/s13239-024-00721-6. [PMID: 38782877 DOI: 10.1007/s13239-024-00721-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 02/04/2024] [Indexed: 05/25/2024]
Abstract
PURPOSE To enhance the performance of machine learning (ML) models for the post-embolization recanalization of cerebral aneurysms, we evaluated the impact of hemodynamic feature derivation and selection method on six ML algorithms. METHODS We utilized computational fluid dynamics (CFD) to simulate hemodynamics in 66 cerebral aneurysms from 65 patients, including 57 stable and nine recanalized aneurysms. We derived a total of 107 features for each aneurysm, encompassing four clinical features, 12 morphological features, and 91 hemodynamic features. To investigate the influence of feature derivation and selection methods on the ML models, we employed two derivation methods, simplified and fully derived, in combination with four selection methods: all features, statistically significant analysis, stepwise multivariate logistic regression analysis (stepwise-LR), and recursive feature elimination (RFE). Model performance was assessed using the area under the receiver operating characteristic curve (AUROC) and precision-recall curve (AUPRC) on both the training and testing datasets. RESULTS The AUROC values on the testing dataset exhibited a wide-ranging spectrum, spanning from 0.373 to 0.863. Fully derived features and the RFE selection method demonstrated superior performance in intra-model comparisons. The multi-layer perceptron (MLP) model, trained with RFE-selected fully derived features, achieved the best performance on the testing dataset, with an AUROC value of 0.863 (95% CI: 0.684- 1.000). CONCLUSION Our study demonstrated the importance of feature derivation and selection in determining the performance of ML models. This enabled the development of accurate decision-making models without the need to invade the patient.
Collapse
Affiliation(s)
- Jing Liao
- Division of Transdisciplinary Sciences, Graduate School of Frontier Science Initiative, Kanazawa University, Ishikawa, Japan.
| | - Kouichi Misaki
- Department of Neurosurgery, Kanazawa University, Ishikawa, Japan
| | - Jiro Sakamoto
- Division of Mechanical Science and Engineering, Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa, Ishikawa, Japan
| |
Collapse
|
2
|
Satoh T, Sugiu K, Hiramatsu M, Haruma J, Date I. Evaluation of the shrinkage process of a neck remnant after stent-coil treatment of a cerebral aneurysm using silent magnetic resonance angiography and computational fluid dynamics analysis: illustrative case. JOURNAL OF NEUROSURGERY. CASE LESSONS 2024; 7:CASE24141. [PMID: 38621304 PMCID: PMC11023012 DOI: 10.3171/case24141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Accepted: 03/13/2024] [Indexed: 04/17/2024]
Abstract
BACKGROUND Silent magnetic resonance angiography (MRA) mitigates metal artifacts, facilitating clear visualization of neck remnants after stent and coil embolization of cerebral aneurysms. This study aims to scrutinize hemodynamics at the neck remnant by employing silent MRA and computational fluid dynamics. OBSERVATIONS The authors longitudinally tracked images of a partially thrombosed anterior communicating artery aneurysm's neck remnant, which had been treated with stent-assisted coil embolization, using silent MRA over a decade. Computational fluid dynamics delineated the neck remnant's reduction process, evaluating hemodynamic parameters such as flow rate, wall shear stress magnitude and vector, and streamlines. The neck remnant exhibited diminishing surface area, volume, neck size, dome depth, and aspect ratio. Its reduction correlated with a decline in the flow rate ratio of the remnant dome to the inflow parent artery. Analysis delineated regions within the contracting neck remnant characterized by consistently low average wall shear stress magnitude and variation, accompanied by notable variations in wall shear stress vector directionality. LESSONS Evaluation of neck remnants after stent-coil embolization is possible through silent MRA and computational fluid dynamics. Predicting the neck remnant reduction may be achievable through hemodynamic parameter analysis.
Collapse
Affiliation(s)
- Toru Satoh
- Departments of Neurological Surgery, Ryofukai Satoh Neurosurgical Hospital, Hiroshima, Japan
| | - Kenji Sugiu
- Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan; and
| | - Masafumi Hiramatsu
- Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan; and
| | - Jun Haruma
- Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan; and
| | - Isao Date
- Okayama Rosai Hospital, Okayama, Japan
| |
Collapse
|
3
|
Liao J, Misaki K, Uno T, Futami K, Nakada M, Sakamoto J. Determination of Significant Three-Dimensional Hemodynamic Features for Postembolization Recanalization in Cerebral Aneurysms Through Explainable Artificial Intelligence. World Neurosurg 2024; 184:e166-e177. [PMID: 38246531 DOI: 10.1016/j.wneu.2024.01.076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 01/12/2024] [Accepted: 01/13/2024] [Indexed: 01/23/2024]
Abstract
BACKGROUND Recanalization poses challenges after coil embolization in cerebral aneurysms. Establishing predictive models for postembolization recanalization is important for clinical decision making. However, conventional statistical and machine learning (ML) models may overlook critical parameters during the initial selection process. METHODS In this study, we automated the identification of significant hemodynamic parameters using a PointNet-based deep neural network (DNN), leveraging their three-dimensional spatial features. Further feature analysis was conducted using saliency mapping, an explainable artificial intelligence (XAI) technique. The study encompassed the analysis of velocity, pressure, and wall shear stress in both precoiling and postcoiling models derived from computational fluid dynamics simulations for 58 aneurysms. RESULTS Velocity was identified as the most pivotal parameter, supported by the lowest P value from statistical analysis and the highest area under the receiver operating characteristic curves/precision-recall curves values from the DNN model. Moreover, visual XAI analysis showed that robust injection flow zones, with notable impingement points in precoiling models, as well as pronounced interplay between flow dynamics and the coiling plane, were important three-dimensional features in identifying the recanalized aneurysms. CONCLUSIONS The combination of DNN and XAI was found to be an accurate and explainable approach not only at predicting postembolization recanalization but also at discovering unknown features in the future.
Collapse
Affiliation(s)
- Jing Liao
- Division of Transdisciplinary Sciences, Graduate School of Frontier Science Initiative, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Kouichi Misaki
- Department of Neurosurgery, Kanazawa University, Kanazawa, Ishikawa, Japan.
| | - Tekehiro Uno
- Department of Neurosurgery, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Kazuya Futami
- Department of Neurosurgery, Hokuriku Central Hospital, Oyabe, Toyama, Japan
| | - Mitsutoshi Nakada
- Department of Neurosurgery, Kanazawa University, Kanazawa, Ishikawa, Japan
| | - Jiro Sakamoto
- Division of Mechanical Science and Engineering, Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa, Ishikawa, Japan
| |
Collapse
|
4
|
Liao J, Misaki K, Uno T, Nambu I, Kamide T, Chen Z, Nakada M, Sakamoto J. Fluid dynamic analysis in predicting the recanalization of intracranial aneurysms after coil embolization - A study of spatiotemporal characteristics. Heliyon 2024; 10:e22801. [PMID: 38226254 PMCID: PMC10788401 DOI: 10.1016/j.heliyon.2023.e22801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 10/09/2023] [Accepted: 11/20/2023] [Indexed: 01/17/2024] Open
Abstract
Purpose Hemodynamics play a key role in the management of cerebral aneurysm recanalization after coil embolization; however, the most reliable hemodynamic parameter remains unknown. Previous studies have explored the use of both spatiotemporally averaged and maximal definitions for hemodynamic parameters, based on computational fluid dynamics (CFD) analysis, to build predictive models for aneurysmal recanalization. In this study, we aimed to assess the influence of different spatiotemporal characteristics of hemodynamic parameters on predictive performance. Methods Hemodynamics were simulated using CFD for 66 cerebral aneurysms from 65 patients. We evaluated 14 types of spatiotemporal definitions for two hemodynamic parameters in the pre-coiling model and five in virtual post-coiling model (VM) created by cutting the aneurysm from the pre-coiling model. A total of 91 spatiotemporal hemodynamic features were derived and utilized to develop univariate predictor (UP) and multivariate logistic regression (LR) models. The model's performance was assessed using two metrics: the area under the receiver operating characteristic curve (AUROC) and the area under the precision-recall curve (AUPRC). Results Different spatiotemporal hemodynamic features exhibited a wide range of AUROC values ranging from 0.224 to 0.747, with 22 feature pairs showing a significant difference in AUROC value (P-value <0.05), despite being derived from the same hemodynamic parameter. PDave,q1 was identified as the strongest UP with AUROC/AUPRC values of 0.747/0.385, yielding sensitivity and specificity value of 0.889 and 0.614 at the optimal cut-off value, respectively. The LR model further improved the prediction performance, having AUROC/AUPRC values of 0.890/0.903. At the optimal cut-off value, the LR model achieved a specificity of 0.877, sensitivity of 0.719, outperforming the UP model. Conclusion Our research indicated that the characteristics of hemodynamic parameters in terms of space and time had a significant impact on the development of predictive model. Our findings suggest that LR model based on spatiotemporal hemodynamic features could be clinically useful in predicting recanalization after coil embolization in patients, without the need for invasive procedures.
Collapse
Affiliation(s)
- Jing Liao
- Division of Transdisciplinary Sciences, Graduate School of Frontier Science Initiative, Kanazawa University, Ishikawa, Japan
| | - Kouichi Misaki
- Department of Neurosurgery, Kanazawa University, Ishikawa, Japan
| | - Tekehiro Uno
- Department of Neurosurgery, Kanazawa University, Ishikawa, Japan
| | - Iku Nambu
- Department of Neurosurgery, Kanazawa University, Ishikawa, Japan
| | - Tomoya Kamide
- Department of Neurosurgery, Kanazawa University, Ishikawa, Japan
| | - Zhuoqing Chen
- Department of Nuclear Medicine, Kanazawa University, Ishikawa, Japan
| | | | - Jiro Sakamoto
- Division of Mechanical Science and Engineering, Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa, Ishikawa, Japan
| |
Collapse
|
5
|
Fillingham P, Romero Bhathal J, Marsh LMM, Barbour MC, Kurt M, Ionita CN, Davies JM, Aliseda A, Levitt MR. Improving the accuracy of computational fluid dynamics simulations of coiled cerebral aneurysms using finite element modeling. J Biomech 2023; 157:111733. [PMID: 37527606 PMCID: PMC10528313 DOI: 10.1016/j.jbiomech.2023.111733] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 05/26/2023] [Accepted: 07/18/2023] [Indexed: 08/03/2023]
Abstract
Cerebral aneurysms are a serious clinical challenge, with ∼half resulting in death or disability. Treatment via endovascular coiling significantly reduces the chances of rupture, but the techniquehas failure rates of ∼20 %. This presents a pressing need to develop a method fordetermining optimal coildeploymentstrategies. Quantification of the hemodynamics of coiled aneurysms using computational fluid dynamics (CFD) has the potential to predict post-treatment outcomes, but representing the coil mass in CFD simulations remains a challenge. We use the Finite Element Method (FEM) for simulating patient-specific coil deployment for n = 4 ICA aneurysms for which 3D printed in vitro models were also generated, coiled, and scanned using ultra-high resolution synchrotron micro-CT. The physical and virtual coil geometries were voxelized onto a binary structured grid and porosity maps were generated for geometric comparison. The average binary accuracy score is 0.8623 and the average error in porosity map is 4.94 %. We then conduct patient-specific CFD simulations of the aneurysm hemodynamics using virtual coils geometries, micro-CT generated oil geometries, and using the porous medium method to represent the coil mass. Hemodynamic parameters including Neck Inflow Rate (Qneck) and Wall Shear Stress (WSS) were calculated for each of the CFD simulations. The average relative error in Qneck and WSS from CFD using FEM geometry were 6.6 % and 21.8 % respectively, while the error from CFD using a porous media approximation resulted in errors of 55.1 % and 36.3 % respectively; demonstrating a marked improvement in the accuracy of CFD simulations using FEM generated coil geometries.
Collapse
Affiliation(s)
- Patrick Fillingham
- Department of Neurological Surgery, University of Washington, Seattle, WA, United States.
| | | | - Laurel M M Marsh
- Department of Mechanical Engineering, University of Washington, Seattle, WA, United States
| | - Michael C Barbour
- Department of Mechanical Engineering, University of Washington, Seattle, WA, United States
| | - Mehmet Kurt
- Department of Mechanical Engineering, University of Washington, Seattle, WA, United States
| | - Ciprian N Ionita
- Department of Biomedical Engineering, University at Buffalo, Buffalo, NY, United States
| | - Jason M Davies
- Department of Neurosurgery, University at Buffalo, Buffalo, NY, United States
| | - Alberto Aliseda
- Department of Mechanical Engineering, University of Washington, Seattle, WA, United States
| | - Michael R Levitt
- Department of Neurological Surgery, University of Washington, Seattle, WA, United States; Department of Mechanical Engineering, University of Washington, Seattle, WA, United States; Department of Radiology, University of Washington, Seattle, WA, United States
| |
Collapse
|
6
|
Bass DI, Marsh LMM, Fillingham P, Lim D, Chivukula VK, Kim LJ, Aliseda A, Levitt MR. Modeling the Mechanical Microenvironment of Coiled Cerebral Aneurysms. J Biomech Eng 2023; 145:041005. [PMID: 36193892 PMCID: PMC9791668 DOI: 10.1115/1.4055857] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 09/09/2022] [Indexed: 12/30/2022]
Abstract
Successful occlusion of cerebral aneurysms using coil embolization is contingent upon stable thrombus formation, and the quality of the thrombus depends upon the biomechanical environment. The goal of this study was to investigate how coil embolization alters the mechanical micro-environment within the aneurysm dome. Inertialess particles were injected in three-dimensional, computational simulations of flow inside patient aneurysms using patient-specific boundary conditions. Coil embolization was simulated as a homogenous porous medium of known permeability and inertial constant. Lagrangian particle tracking was used to calculate the residence time and shear stress history for particles in the flow before and after treatment. The percentage of particles entering the aneurysm dome correlated with the neck surface area before and after treatment (pretreatment: R2 = 0.831, P < 0.001; post-treatment: R2 = 0.638, P < 0.001). There was an inverse relationship between the change in particles entering the dome and coil packing density (R2 = 0.600, P < 0.001). Following treatment, the particles with the longest residence times tended to remain within the dome even longer while accumulating lower shear stress. A significant correlation was observed between the treatment effect on residence time and the ratio of the neck surface area to porosity (R2 = 0.390, P = 0.007). The results of this study suggest that coil embolization triggers clot formation within the aneurysm dome via a low shear stress-mediated pathway. This hypothesis links independently observed findings from several benchtop and clinical studies, furthering our understanding of this treatment strategy.
Collapse
Affiliation(s)
- David I. Bass
- Department of Neurological Surgery, University of Washington, 325 9th Avenue, Box 359924, Seattle, WA 98104
| | - Laurel M. M. Marsh
- Department of Mechanical Engineering, University of Washington, 3900 East Stevens Way NE, Box 352600, Seattle, WA 98195
| | - Patrick Fillingham
- Department of Neurological Surgery, Stroke & Applied Neuroscience Center, University of Washington, 325 9th Avenue, Box 359924, Seattle, WA 98104
| | - Do Lim
- Department of Neurological Surgery, Stroke & Applied Neuroscience Center, University of Washington, 325 9th Avenue, Box 359924, Seattle, WA 98104
| | - V. Keshav Chivukula
- Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, 150 West University Building, Melbourne, FL 32901
| | - Louis J. Kim
- Department of Neurological Surgery, Stroke & Applied Neuroscience Center, University of Washington, 325 9th Avenue, Box 359924, Seattle, WA 98104; Department of Radiology, University of Washington, 325 9th Avenue, Box 359924, Seattle, WA 98104
| | - Alberto Aliseda
- Department of Mechanical Engineering, Stroke & Applied Neuroscience Center, University of Washington, 3900 East Stevens Way NE, Box 352600, Seattle, WA 98195; Department of Neurological Surgery, Stroke & Applied Neuroscience Center, University of Washington, 3900 East Stevens Way NE, Box 352600, Seattle, WA 98195
| | - Michael R. Levitt
- Department of Neurological Surgery, Stroke & Applied Neuroscience Center, University of Washington, 325 9th Avenue, Box 359924, Seattle, WA 98104; Department of Radiology, University of Washington, 325 9th Avenue, Box 359924, Seattle, WA 98104; Department of Mechanical Engineering, University of Washington, 325 9th Avenue, Box 359924, Seattle, WA 98104
| |
Collapse
|
7
|
Masuda S, Fujimura S, Takao H, Takeshita K, Suzuki T, Uchiyama Y, Karagiozov K, Ishibashi T, Fukudome K, Yamamoto M, Murayama Y. Effects of different stent wire mesh densities on hemodynamics in aneurysms of different sizes. PLoS One 2022; 17:e0269675. [PMID: 35687558 PMCID: PMC9187070 DOI: 10.1371/journal.pone.0269675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 05/25/2022] [Indexed: 11/25/2022] Open
Abstract
Background Intracranial stents are used to treat aneurysms by diverting the blood flow from entering into the aneurysmal dome. Although delayed rupture is rare, clinical outcomes are extremely poor in such cases. Hemodynamics after stent deployment may be related to delayed rupture and a better understanding of the basic characteristics of pressure changes resulting from stent deployment is needed; therefore, this study investigated the relationships between hemodynamics in aneurysms of different sizes treated using stents of different wire mesh densities. Methods Using computational fluid dynamics analysis, parameters related to velocity, volume flow rate, pressure, and residual volume inside the aneurysm were evaluated in digital models of 5 basic aneurysms of differing sizes (Small, Medium, Medium-Large, Large, and Giant) and using 6 different types of stent (varying number of wires, stent pitch and wire mesh density) for each aneurysm. Results Regardless of the aneurysm size, the velocity inside the aneurysm and the volume flow rate into the aneurysm were observed to continuously decrease up to 89.2% and 78.1%, respectively, with increasing stent mesh density. In terms of pressure, for giant aneurysms, the pressure on the aneurysmal surface elevated to 10.3%, then decreased to 5.1% with increasing stent mesh density. However, in smaller aneurysms, this pressure continuously decreased with increasing stent mesh density. The flow-diverting effect of the stents was limited when a stent with low mesh density (under 20%) was used with a giant aneurysm. Conclusions The present results indicate that the selection of appropriate stents according to aneurysm size may contribute to reduced risks of hemodynamic alternations related to stent deployment, which could reduce the incidence of delayed rupture.
Collapse
Affiliation(s)
- Shunsuke Masuda
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan
- Cybernet Systems Co., Ltd., Tokyo, Japan
| | - Soichiro Fujimura
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan
- Department of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
| | - Hiroyuki Takao
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan
- Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan
- Graduate School of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
- * E-mail:
| | - Kohei Takeshita
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan
| | - Takashi Suzuki
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan
- Digital Health & SYNGO Department, Siemens Healthcare K.K., Tokyo, Japan
| | - Yuya Uchiyama
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan
- Graduate School of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
| | - Kostadin Karagiozov
- Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Toshihiro Ishibashi
- Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Koji Fukudome
- Department of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
| | - Makoto Yamamoto
- Department of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
| | - Yuichi Murayama
- Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan
| |
Collapse
|
8
|
Chen L, Leng X, Zheng C, Shan Y, Wang M, Bao X, Wu J, Zou R, Liu X, Xu S, Xiang J, Wan S. Computational fluid dynamics (CFD) analysis in a ruptured vertebral artery dissecting aneurysm implanted by Pipeline when recurrent after LVIS-assisted coiling treatment: Case report and review of the literatures. Interv Neuroradiol 2022:15910199221097766. [PMID: 35484808 PMCID: PMC10399494 DOI: 10.1177/15910199221097766] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUNDS Hemodynamics plays an important role in the natural history of the process of rupture and recurrence of intracranial aneurysms. This study aimed to investigate the role of hemodynamics for recurrence in a vertebral artery dissecting aneurysm (VADA). METHODS A patient with a ruptured VADA firstly treated by low-profile visualized intraluminal support (LVIS)-assisted coiling, and was implanted with a Pipeline Embolization Device (PED) after aneurysm recurrence. Finite element analysis and computational fluid dynamics simulations were conducted in 6 serial imaging procedures, and the calculated hemodynamics was correlated with aneurysm recurrence. RESULTS Wall shear stress (WSS) was not effectively suppressed, resulting in aneurysm recurrence with initial entry tear to occur above the protuberance after 7 months of LVIS stent-assisted coiling. With the implantation of PED, WSS, inflow stream and velocity at the aneurysm neck significantly decreased. During the 3-month follow-up after PED deployment, there was significant shrinkage of the sac and the blood flow in the sac was reduced considerably. The 27-month follow-up after PED deployment indicated the aneurysm was stable. CONCLUSIONS The present case study suggests that insufficient suppression of high WSS and high inflow velocity at the neck of the parent artery, especially near the posterior inferior cerebellar artery, might be associated with aneurysm recurrence.
Collapse
Affiliation(s)
- Linhui Chen
- Brain Center, Affiliated Zhejiang Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | | | - Chaobo Zheng
- Brain Center, Affiliated Zhejiang Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Yejie Shan
- 611825ArteryFlow Technology Co., Ltd. Hangzhou, China
| | - Ming Wang
- Brain Center, Affiliated Zhejiang Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Xiang Bao
- Department of Neurosurgery, 117946Jinhua Central Hospital, Jinhua, China
| | - Jiong Wu
- Brain Center, Affiliated Zhejiang Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Rong Zou
- 611825ArteryFlow Technology Co., Ltd. Hangzhou, China
| | - Xiaobo Liu
- Department of Neurosurgery, 117946Jinhua Central Hospital, Jinhua, China
| | - Shanhu Xu
- Brain Center, Affiliated Zhejiang Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | | | - Shu Wan
- Brain Center, Affiliated Zhejiang Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
9
|
Uchiyama Y, Fujimura S, Takao H, Ono H, Katayama K, Suzuki T, Ishibashi T, Otani K, Karagiozov K, Fukudome K, Murayama Y, Yamamoto M. Extraction of patient-specific boundary conditions from 4D-DSA and their influence on CFD simulations of cerebral aneurysms. Comput Methods Biomech Biomed Engin 2022; 25:1222-1234. [PMID: 35195493 DOI: 10.1080/10255842.2021.2005035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
We developed a new technique for extracting patient-specific inflow conditions, such as the pulse cycle duration and blood flow velocity, from four-dimensional digital subtraction angiography images and experimentally examined its validity. The maximum error between the values extracted by the technique and measured values was 14.3%. We performed blood flow simulations and calculated representative haemodynamic parameters. The maximum differences between the parameters obtained using general and patient-specific inflow conditions were approximately 400%, 150%, and 50% for the velocity, normalised wall shear stress, and pressure loss coefficient, respectively. These results indicate that patient-specific conditions are critical for accurately reproducing aneurysmal haemodynamics.
Collapse
Affiliation(s)
- Yuya Uchiyama
- Graduate School of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan.,Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan
| | - Soichiro Fujimura
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.,Department of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
| | - Hiroyuki Takao
- Graduate School of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan.,Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.,Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Hiroshi Ono
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan
| | - Keigo Katayama
- Graduate School of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
| | - Takashi Suzuki
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.,Siemens Healthcare Japan K.K., Tokyo, Japan
| | - Toshihiro Ishibashi
- Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Katharina Otani
- Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.,Siemens Healthcare Japan K.K., Tokyo, Japan
| | - Kostadin Karagiozov
- Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Koji Fukudome
- Department of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
| | - Yuichi Murayama
- Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Makoto Yamamoto
- Department of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan
| |
Collapse
|
10
|
Wisniewski AG, Shiraz Bhurwani MM, Sommer KN, Monteiro A, Baig A, Davies J, Siddiqui A, Ionita CN. Quantitative angiography prognosis of intracranial aneurysm treatment failure using parametric imaging and distal vessel analysis. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2022; 12036:120360D. [PMID: 35983494 PMCID: PMC9385187 DOI: 10.1117/12.2611550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
PURPOSE Data-driven methods based on x-ray angiographic parametric imaging (API) have been successfully used to provide prognosis for intracranial aneurysm (IA) treatment outcome. Previous studies have mainly focused on embolization devices where the flow pattern visualization is in the aneurysm dome; however, this is not possible in IAs treated with endovascular coils due to high x-ray attenuation of the devices. To circumvent this challenge, we propose to investigate whether flow changes in the parent artery distal to the coil-embolized IAs could be used to achieve the same accuracy of surgical outcome prognosis. METHODS Eighty digital subtraction angiography sequences were acquired from patients with IA embolized with coils. Five API parameters were recorded from a region of interest (ROI) placed distal to the IA neck in the main artery. Average API values were recorded and pre-treatment values. A supervised machine learning algorithm was trained to provide a six-month post procedure binary outcome (occluded/not occluded). Receiver operating characteristic (ROC) analysis was used to assess the accuracy of the method. RESULTS Use of API parameters with data driven methods yielded an area under the ROC curve of 0.77 ±0.11 and accuracy of 78.6%. Single parameter-based analysis yielded accuracies which were suboptimal for clinical acceptance. CONCLUSIONS We determined that data-driven method based on API analysis of flow in the parent artery of IA treated with coils provide clinically acceptable accuracy for the prognosis of six months occlusion outcome.
Collapse
Affiliation(s)
- Alexander G Wisniewski
- Department of Biomedical Engineering, University at Buffalo, Buffalo NY 14228
- Canon Stroke and Vascular Research Center, Buffalo, NY 14203
| | - Mohammad Mahdi Shiraz Bhurwani
- Department of Biomedical Engineering, University at Buffalo, Buffalo NY 14228
- Canon Stroke and Vascular Research Center, Buffalo, NY 14203
| | - Kelsey N Sommer
- Department of Biomedical Engineering, University at Buffalo, Buffalo NY 14228
- Canon Stroke and Vascular Research Center, Buffalo, NY 14203
- QAS.AI Incorporated, Buffalo NY 14203
| | - Andre Monteiro
- Canon Stroke and Vascular Research Center, Buffalo, NY 14203
- University at Buffalo Neurosurgery, University at Buffalo Jacobs School of Medicine, Buffalo NY 14228
| | - Ammad Baig
- Canon Stroke and Vascular Research Center, Buffalo, NY 14203
- University at Buffalo Neurosurgery, University at Buffalo Jacobs School of Medicine, Buffalo NY 14228
| | - Jason Davies
- Canon Stroke and Vascular Research Center, Buffalo, NY 14203
- University at Buffalo Neurosurgery, University at Buffalo Jacobs School of Medicine, Buffalo NY 14228
- QAS.AI Incorporated, Buffalo NY 14203
- University Dept. of Biomedical Informatics, University at Buffalo, Buffalo, NY 14214
| | - Adnan Siddiqui
- Canon Stroke and Vascular Research Center, Buffalo, NY 14203
- University at Buffalo Neurosurgery, University at Buffalo Jacobs School of Medicine, Buffalo NY 14228
- University Dept. of Biomedical Informatics, University at Buffalo, Buffalo, NY 14214
| | - Ciprian N Ionita
- Department of Biomedical Engineering, University at Buffalo, Buffalo NY 14228
- Canon Stroke and Vascular Research Center, Buffalo, NY 14203
- University at Buffalo Neurosurgery, University at Buffalo Jacobs School of Medicine, Buffalo NY 14228
- QAS.AI Incorporated, Buffalo NY 14203
| |
Collapse
|
11
|
Fujimura S, Brehm A, Takao H, Uchiyama Y, Karagiozov K, Fukudome K, Yamamoto M, Murayama Y, Psychogios MN. Hemodynamic Characteristics and Clinical Outcome for Intracranial Aneurysms treated with the Derivo Embolization Device, a Novel Second-Generation Flow Diverter. World Neurosurg 2021; 159:e252-e259. [PMID: 34929366 DOI: 10.1016/j.wneu.2021.12.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Accepted: 12/10/2021] [Indexed: 10/19/2022]
Abstract
BACKGROUND AND PURPOSE We investigated the relationship between hemodynamic characteristics and clinical outcomes for aneurysms treated by the Derivo Embolization Device (DED), a novel second-generation Flow-Diverter Stent, using computational fluid dynamics (CFD). MATERIALS AND METHODS Data were retrospectively obtained from two centers between 2017 and 2019. During the period, 23 patients were treated for 23 aneurysms with DED. In 17 patients we were able to conduct CFD analysis as six were excluded due to pre-coiling, unsuitable arterial geometry, and complex geometric form. Aneurysm occlusion was rated with the O`Kelly-Marotta (OKM) grading scale on DSA 6 months after stent placement in all patients. Hemodynamic and morphological parameters were statistically compared between two groups: with full occlusion and with a remnant. RESULTS Full occlusion was observed in 17 out of 23 (73.9%) patients. In the group suitable for CFD analysis, we observed 13 fully occluded aneurysms and 4 with any remnant (specifically 1 OKM C, 1 B and 2 A). The energy loss per volume (ELV), which indicates the energy loss through the aneurysm, was significantly larger in pre and post stenting (p<.05) in the complete occlusion cases. In addition, the inflow concentration index (ICI) and inflow area ratio (IAR) of the remnant cases were significantly larger and lower, respectively (p<.05). CONCLUSION Our CFD results indicate that the energy loss involved with the blood flow passing through an aneurysm and concentrated inflow into aneurysm were the most important factors to determine whether an aneurysm will become a complete occlusion or remnant case.
Collapse
Affiliation(s)
- Soichiro Fujimura
- Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan; Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Alex Brehm
- Department of Neuroradiology, Clinic for Radiology & Nuclear Medicine, University Hospital Basel, Basel, Switzerland
| | - Hiroyuki Takao
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Graduate School of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| | - Yuya Uchiyama
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Graduate School of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| | - Kostadin Karagiozov
- Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Koji Fukudome
- Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| | - Makoto Yamamoto
- Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| | - Yuichi Murayama
- Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Marios-Nikos Psychogios
- Department of Neuroradiology, Clinic for Radiology & Nuclear Medicine, University Hospital Basel, Basel, Switzerland.
| |
Collapse
|
12
|
Ou C, Liu J, Qian Y, Chong W, Liu D, He X, Zhang X, Duan CZ. Automated Machine Learning Model Development for Intracranial Aneurysm Treatment Outcome Prediction: A Feasibility Study. Front Neurol 2021; 12:735142. [PMID: 34912282 PMCID: PMC8666475 DOI: 10.3389/fneur.2021.735142] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 11/01/2021] [Indexed: 11/30/2022] Open
Abstract
Background: The prediction of aneurysm treatment outcomes can help to optimize the treatment strategies. Machine learning (ML) has shown positive results in many clinical areas. However, the development of such models requires expertise in ML, which is not an easy task for surgeons. Objectives: The recently emerged automated machine learning (AutoML) has shown promise in making ML more accessible to non-computer experts. We aimed to evaluate the feasibility of applying AutoML to develop the ML models for treatment outcome prediction. Methods: The patients with aneurysms treated by endovascular treatment were prospectively recruited from 2016 to 2020. Treatment was considered successful if angiographic complete occlusion was achieved at follow-up. A statistical prediction model was developed using multivariate logistic regression. In addition, two ML models were developed. One was developed manually and the other was developed by AutoML. Three models were compared based on their area under the precision-recall curve (AUPRC) and area under the receiver operating characteristic curve (AUROC). Results: The aneurysm size, stent-assisted coiling (SAC), and posterior circulation were the three significant and independent variables associated with treatment outcome. The statistical model showed an AUPRC of 0.432 and AUROC of 0.745. The conventional manually trained ML model showed an improved AUPRC of 0.545 and AUROC of 0.781. The AutoML derived ML model showed the best performance with AUPRC of 0.632 and AUROC of 0.832, significantly better than the other two models. Conclusions: This study demonstrated the feasibility of using AutoML to develop a high-quality ML model, which may outperform the statistical model and manually derived ML models. AutoML could be a useful tool that makes ML more accessible to the clinical researchers.
Collapse
Affiliation(s)
- Chubin Ou
- Neurosurgery Center, Department of Cerebrovascular Surgery, The National Key Clinical Specialty, The Engineering Technology Research Center of Education Ministry of China on Diagnosis and Treatment of Cerebrovascular Disease, Guangdong Provincial Key Laboratory on Brain Function Repair and Regeneration, The Neurosurgery Institute of Guangdong Province, Zhujiang Hospital, Southern Medical University, Guangzhou, China.,Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, NSW, Australia
| | - Jiahui Liu
- Neurosurgery Center, Department of Cerebrovascular Surgery, The National Key Clinical Specialty, The Engineering Technology Research Center of Education Ministry of China on Diagnosis and Treatment of Cerebrovascular Disease, Guangdong Provincial Key Laboratory on Brain Function Repair and Regeneration, The Neurosurgery Institute of Guangdong Province, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Yi Qian
- Neurosurgery Center, Department of Cerebrovascular Surgery, The National Key Clinical Specialty, The Engineering Technology Research Center of Education Ministry of China on Diagnosis and Treatment of Cerebrovascular Disease, Guangdong Provincial Key Laboratory on Brain Function Repair and Regeneration, The Neurosurgery Institute of Guangdong Province, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Winston Chong
- Monash Medical Centre, Monash University, Clayton, VIC, Australia
| | - Dangqi Liu
- Department of Neurosurgery, The First People's Hospital of Foshan, Foshan, China
| | - Xuying He
- Neurosurgery Center, Department of Cerebrovascular Surgery, The National Key Clinical Specialty, The Engineering Technology Research Center of Education Ministry of China on Diagnosis and Treatment of Cerebrovascular Disease, Guangdong Provincial Key Laboratory on Brain Function Repair and Regeneration, The Neurosurgery Institute of Guangdong Province, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Xin Zhang
- Neurosurgery Center, Department of Cerebrovascular Surgery, The National Key Clinical Specialty, The Engineering Technology Research Center of Education Ministry of China on Diagnosis and Treatment of Cerebrovascular Disease, Guangdong Provincial Key Laboratory on Brain Function Repair and Regeneration, The Neurosurgery Institute of Guangdong Province, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Chuan-Zhi Duan
- Neurosurgery Center, Department of Cerebrovascular Surgery, The National Key Clinical Specialty, The Engineering Technology Research Center of Education Ministry of China on Diagnosis and Treatment of Cerebrovascular Disease, Guangdong Provincial Key Laboratory on Brain Function Repair and Regeneration, The Neurosurgery Institute of Guangdong Province, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| |
Collapse
|
13
|
Ishii T, Fujimura S, Takao H, Uchiyama Y, Okudaira T, Ishibashi T, Otani K, Karagiozov K, Fukudome K, Yamamoto M, Murayama Y. Hemodynamic and Morphological Factors Related to Coil Compaction in Basilar Artery Tip Aneurysms. World Neurosurg 2021; 155:e95-e110. [PMID: 34389523 DOI: 10.1016/j.wneu.2021.08.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/02/2021] [Accepted: 08/03/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Coil compaction is directly related to the degree of cerebral aneurysmal recanalization. The Degree of Recanalization (DoR) was quantified by measuring the volume vacated by coil deformation. The purpose of this study was to clarify the hemodynamic and morphological factors associated with coil compaction. METHODS Computational fluid dynamics (CFD) simulations were performed on 28 middle size (5-10 mm), unruptured basilar artery tip aneurysms. The DoR was measured by comparing the coil mass shape obtained from three-dimensional digital subtraction angiography data immediately after coil embolization and again within 1 to 2 years of follow-up. Deployed coils were modeled using a virtual coiling technique for CFD simulations. Hemodynamic and morphological factors to predict the DoR were derived using multiple linear regression. RESULTS Aneurysmal neck area, the maximum pressure generated on the neck surface after coil embolization, and the high-pressure position on the neck surface predicted DoR with statistical significance (p<0.001, p<0.001, p=0.004, respectively). DoR tended to increase when the neck area was large, the pressure generated on the coils was high, and the high-pressure position was close to the center of the neck surface. The volume embolization ratio was not statistically relevant for the DoR in the cases of this study. CONCLUSIONS Coil compaction occurs in cerebral aneurysms with a wide neck, high pressure generated on the coils, and high pressure in the center of the neck surface. Establishing the DoR can contribute to the prediction of recanalization after coil embolization.
Collapse
Affiliation(s)
- Takumi Ishii
- Graduate School of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan; Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Soichiro Fujimura
- Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| | - Hiroyuki Takao
- Graduate School of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan; Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Yuya Uchiyama
- Graduate School of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan; Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Takuma Okudaira
- Graduate School of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan; Department of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Toshihiro Ishibashi
- Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Katharina Otani
- Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Siemens Healthcare K.K. 1-11-1 Osaki, Shinagawa-ku, Tokyo 141-8644, Japan
| | - Kostadin Karagiozov
- Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan
| | - Koji Fukudome
- Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| | - Makoto Yamamoto
- Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| | - Yuichi Murayama
- Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan.
| |
Collapse
|
14
|
Suzuki T, Genkai N, Nomura T, Abe H. Assessing the Hemodynamics in Residual Cavities of Intracranial Aneurysm after Coil Embolization with Combined Computational Flow Dynamics and Silent Magnetic Resonance Angiography. J Stroke Cerebrovasc Dis 2020; 29:105290. [PMID: 32992205 DOI: 10.1016/j.jstrokecerebrovasdis.2020.105290] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 08/21/2020] [Accepted: 08/26/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND AND PURPOSE Metal artifacts limit computational fluid dynamics analysis after coil embolization. Silent magnetic resonance angiography reduces metal artifacts and improves visualization of the residual cavity of coil-embolized aneurysms. This study investigated the flow dynamics of the residual cavity after coil embolization using silent magnetic resonance angiography and computational fluid dynamics to elucidate the hemodynamic characteristics of recanalization. METHODS Twenty internal carotid-posterior communicating aneurysm cases treated with coil embolization and without stent assistance were followed up (mean±standard deviation, 13.0±6.1 months) and assessed using silent magnetic resonance angiography. The hemodynamic characteristics of the residual cavities in both types of aneurysms were compared between neck remnants, which persisted for >12 months (NR group), and those treated with coil compaction-induced body filling (BF group). Computational fluid dynamics analysis of each aneurysm was performed using morphological data obtained from silent magnetic resonance angiography. Pressure, pressure difference, normalized wall shear stress, and flow velocity were measured. RESULTS The residual cavity was well-visualized using silent magnetic resonance angiography and compared with those imaged using conventional time-of-flight magnetic resonance angiography, and eight internal carotid-posterior communicating aneurysms with neck remnants and body filling were investigated. The maximum pressure area was localized to the aneurysm wall in the NR group (n=4) and to sides of the coil surface in the BF group (n=4). No significant differences were observed for each hemodynamic parameter. CONCLUSIONS Combination of silent magnetic resonance angiography and computational fluid dynamics helps to understand the hemodynamic characteristics of residual cavity in coil- embolized aneurysms. The flow-impingement zone at the coil surface (maximum pressure area) may influence the risk for future coil compaction.
Collapse
Affiliation(s)
- Tomoaki Suzuki
- Department of Neurosurgery, Tachikawa General Hospital, 1-24 Asahioka, Nagaoka 940-8621, Japan; Department of Neurosurgery, Brain Research Institute, Niigata University, 1-757 Asahimachi-Dori, Niigata 951-8585, Japan.
| | - Nobuyuki Genkai
- Department of Neurosurgery, Tachikawa General Hospital, 1-24 Asahioka, Nagaoka 940-8621, Japan
| | - Toshiharu Nomura
- Department of Neurosurgery, Tachikawa General Hospital, 1-24 Asahioka, Nagaoka 940-8621, Japan
| | - Hiroshi Abe
- Department of Neurosurgery, Tachikawa General Hospital, 1-24 Asahioka, Nagaoka 940-8621, Japan
| |
Collapse
|
15
|
Prediction of internal carotid artery aneurysm recurrence by pressure difference at the coil mass surface. Neuroradiology 2020; 63:593-602. [PMID: 32929545 PMCID: PMC7966142 DOI: 10.1007/s00234-020-02553-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 09/08/2020] [Indexed: 12/23/2022]
Abstract
PURPOSE A previous study on computational fluid dynamics reported that a high pressure difference (PD) at the surface of a coil mass is a strong predictor of aneurysm recurrence after coil embolization. PD was calculated using a virtual post-coiling model (VM), created by manually cutting the aneurysm by the flat plane from an anatomic model created with pre-coil embolization data; however, its credibility has not been fully evaluated. This study aims to clarify whether PD values calculated using the post-coiling model, which reflects the actual coil plane, are a strong predictor of aneurysm recurrence. METHODS Fifty internal carotid artery aneurysms treated with endovascular coil embolization were analyzed (7 recanalized, 43 stable). We created and subjected two post-coiling models, namely, VM and the real post-coiling model (RM), constructed from the post-coil embolization data. The relationship between PD and aneurysm recurrence was examined using these models. PD and its constituent three parameters were compared between VM and RM. RESULTS PD values calculated using RM showed significantly higher aneurysm recurrence in recurrence group than stable group (p < 0.001), and multivariate analysis showed that PD in RM (p = 0.02; odds ratio, 36.24) was significantly associated with aneurysm recurrence. The receiver operating characteristic analysis revealed that PD values accurately predicted aneurysm recurrence (area under the curve, 0.977; cutoff value, 3.08; sensitivity, 100%; specificity, 97.7%). All four parameters showed a significant correlation with VM and RM (p < 0.001). CONCLUSION Use of PD to predict recurrence after coil embolization can be clinically relevant.
Collapse
|
16
|
Murayama Y, Fujimura S, Suzuki T, Takao H. Computational fluid dynamics as a risk assessment tool for aneurysm rupture. Neurosurg Focus 2020; 47:E12. [PMID: 31261116 DOI: 10.3171/2019.4.focus19189] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Accepted: 04/23/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The authors reviewed the clinical role of computational fluid dynamics (CFD) in assessing the risk of intracranial aneurysm rupture. METHODS A literature review was performed to identify reports on CFD assessment of aneurysms using PubMed. The usefulness of various hemodynamic parameters, such as wall shear stress (WSS) and the Oscillatory Shear Index (OSI), and their role in aneurysm rupture risk analysis, were analyzed. RESULTS The authors identified a total of 258 published articles evaluating rupture risk, growth, and endovascular device assessment. Of these 258 articles, 113 matching for CFD and hemodynamic parameters that contribute to the risk of rupture (such as WSS and OSI) were identified. However, due to a lack of standardized methodology, controversy remains on each parameter's role. CONCLUSIONS Although controversy continues to exist on which risk factors contribute to predict aneurysm rupture, CFD can provide additional parameters to assess this rupture risk. This technology can contribute to clinical decision-making or evaluation of efficacy for endovascular methods and devices.
Collapse
Affiliation(s)
- Yuichi Murayama
- Departments of1Neurosurgery and.,2Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo
| | - Soichiro Fujimura
- 2Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo.,3Graduate School of Mechanical Engineering, Tokyo University of Science, Tokyo; and
| | - Tomoaki Suzuki
- 4Department of Neurosurgery, Brain Research Institute, Niigata University, Niigata, Japan
| | - Hiroyuki Takao
- Departments of1Neurosurgery and.,2Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo.,3Graduate School of Mechanical Engineering, Tokyo University of Science, Tokyo; and
| |
Collapse
|
17
|
King RM, Marosfoi M, Caroff J, Ughi GJ, Groth DM, Gounis MJ, Puri AS. High frequency optical coherence tomography assessment of homogenous neck coverage by intrasaccular devices predicts successful aneurysm occlusion. J Neurointerv Surg 2019; 11:1150-1154. [PMID: 31036558 PMCID: PMC8204215 DOI: 10.1136/neurintsurg-2019-014843] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 04/08/2019] [Accepted: 04/08/2019] [Indexed: 11/06/2022]
Abstract
BACKGROUND High frequency optical coherence tomography (HF-OCT) is a novel intravascular imaging technology developed for use in the cerebral vasculature. We hypothesize that HF-OCT characterization of intrasaccular device neck coverage can prognosticate exclusion of the aneurysm from the circulation. METHODS Bifurcation and sidewall aneurysms were made in six dogs. Seven aneurysms were treated with next generation intrasaccular devices (NGID) and four with traditional platinum coils. HF-OCT was performed to interrogate gaps in the neck coverage, coil herniation, or acute thrombus formation. Animals were re-imaged at 7, 30, 90, and 180 days following aneurysm embolization. An automated image processing method segmented the devices at the neck of the aneurysm and quantified neck coverage. The largest coverage gap was used to predict aneurysm occlusion at 180 days. RESULTS No difference was found in occlusion rates between the coil and NGID groups (P=0.45). Successful segmentation of the NGID construct was achieved in all cases. A coverage gap >1 mm2 was found to predict failed aneurysm occlusion (P=0.047). This threshold was able to predict all cases of failed occlusion. The average number of devices needed to treat the aneurysm was lower in the NGID group (1.9 vs 6.75, P=0.009). HF-OCT showed strong agreement with scanning electron microscopy (bias 0.0024 mm2 (95% CI -0.0279, 0.0327)). CONCLUSIONS HF-OCT enables precise and accurate measurement of coverage gaps at the neck of aneurysms treated with intrasaccular devices in vivo. We provide in vivo evidence that uniform aneurysm neck coverage by intrasaccular devices is critical for aneurysm occlusion.
Collapse
Affiliation(s)
- Robert M King
- New England Center for Stroke Research, Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Miklos Marosfoi
- New England Center for Stroke Research, Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA
| | - Jildaz Caroff
- Department of Interventional Neuroradiology, NEURI Center, Bicêtre Hospital, Le Kremlin-Bicêtre, France
| | - Giovanni J Ughi
- New England Center for Stroke Research, Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA
| | - Dale M Groth
- New England Center for Stroke Research, Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA
| | - Matthew J Gounis
- New England Center for Stroke Research, Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA
| | - Ajit S Puri
- New England Center for Stroke Research, Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA
| |
Collapse
|
18
|
Lee SH, Cho YD, Mun JH, Yoo DH, Yeon EK, Kang HS, Kim JE, Cho WS, Han MH. Does Systemic Hypertension Impact Recanalization of Coiled Aneurysms? Clin Neuroradiol 2019; 31:117-124. [PMID: 31468079 DOI: 10.1007/s00062-019-00830-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 08/10/2019] [Indexed: 11/29/2022]
Abstract
PURPOSE It is well known that hypertension is a significant factor in the formation, growth, and rupture of aneurysms and recanalization of coiled aneurysms is affected by hemodynamic stress. At present, however, the impact of hypertension on recanalization of coiled aneurysms has not been adequately investigated. This study examined the relation between hypertension and subsequent outcomes of coiled aneurysms, using a matched patient analysis. METHODS A total of 715 subjects undergoing coil embolization of intracranial aneurysms between 2011 and 2013 were selected for study. Time-of-flight magnetic resonance or conventional angiography was used (singly or together) to gauge degrees of occlusion after coiling, applying the Raymond classification in grading recanalization. Patients with hypertension were grouped as controlled or uncontrolled, based on blood pressure readings at outpatient clinics. Hypertensive and non-hypertensive subjects were matched (1:1) for several relevant variables. RESULTS Overall, 484 patients (67.7%) were hypertensive (controlled 338; uncontrolled 146). During the follow-up period (28.6 ± 9.7 months), 129 aneurysms (18.0%) displayed recanalization (minor 58; major 71). Patient age, concomitant diabetes, hyperlipidemia, aneurysm size, neck size, depth-to-neck ratio, and aneurysm type differed significantly in hypertensive and non-hypertensive groups; however, group incidences of cumulative recanalization were similar (p = 0.297). After 1:1 matching the cumulative recanalization rate (13.5%) in hypertensive and non-hypertensive counterparts (14.3%) again proved similar (p = 0.578). In the hypertensive group, in addition, recanalization showed no relation to controlled and uncontrolled subgroup (odds ratio, OR = 1.000, p > 0.999). CONCLUSION Unlike other aspects of evolving aneurysms (e.g. formation, growth, or rupture), recanalization of coiled aneurysms seems to be unaffected by systemic hypertension.
Collapse
Affiliation(s)
- Su Hwan Lee
- Department of Neurosurgery, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang, Korea (Republic of)
| | - Young Dae Cho
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak-ro, 110-744, Seoul, Korea (Republic of).
| | - Jong Hyeon Mun
- Department of Neurosurgery, Kwangju Christian Hospital, Gwangju, Korea (Republic of)
| | - Dong Hyun Yoo
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak-ro, 110-744, Seoul, Korea (Republic of)
| | - Eung Koo Yeon
- Department of Radiology, KyungHee University Medical Center, KyungHee University College of Medicine, Seoul, Korea (Republic of)
| | - Hyun-Seung Kang
- Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea (Republic of)
| | - Jeong Eun Kim
- Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea (Republic of)
| | - Won-Sang Cho
- Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea (Republic of)
| | - Moon Hee Han
- Department of Radiology, Veterans Health Service Medical Center, Seoul, Korea (Republic of)
| |
Collapse
|
19
|
Schönfeld MH, Forkert ND, Fiehler J, Cho YD, Han MH, Kang HS, Peach TW, Byrne JV. Hemodynamic Differences Between Recurrent and Nonrecurrent Intracranial Aneurysms: Fluid Dynamics Simulations Based on MR Angiography. J Neuroimaging 2019; 29:447-453. [PMID: 30891876 DOI: 10.1111/jon.12612] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Revised: 03/05/2019] [Accepted: 03/06/2019] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND AND PURPOSE Although the role of wall shear stress (WSS) in the initiation, growth, and rupture of intracranial aneurysms has been well studied, its influence on aneurysm recurrence after endovascular treatment requires further investigation. We aimed to compare WSS at necks of recurrent and nonrecurrent aneurysms. METHODS Nine recurrent coil-embolized aneurysms were identified and matched with nine nonrecurrent aneurysms. Patient-specific vessel geometries reconstructed from follow-up 3-D time-of-flight magnetic resonance angiography were analyzed using computational fluid dynamics (CFD) simulations. Absolute WSS and the percentage of abnormally low and high WSS at the aneurysm neck compared to the near artery were measured. RESULTS The median percentage of abnormal WSS at the aneurysm neck was 49.3% for recurrent and 34.7% for nonrecurrent aneurysms (P = .011). The area under the receiver-operating-characteristic curve for distinguishing these aneurysms according to the percentage of abnormal WSS was .86 (95% CI .62 to .98). The optimal cut-off value of 45.1% resulted in a sensitivity and a specificity of 88.89% (95% CI 51.8% to 99.7%). CONCLUSION Our findings indicate that necks of recurrent aneurysms are exposed to abnormal WSS to a larger extent. Abnormal WSS may serve as a metric to distinguish them from nonrecurrent aneurysms with CFD simulations a priori.
Collapse
Affiliation(s)
- Michael Hinrich Schönfeld
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Nils Daniel Forkert
- Department of Radiology and Hotchkiss Brain Institute, University of Calgary, Calgary, Canada
| | - Jens Fiehler
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Young Dae Cho
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Moon Hee Han
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Hyun-Seung Kang
- Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Thomas William Peach
- Department of Mechanical Engineering, University College London, London, UK.,Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
| | - James Vincent Byrne
- Oxford Neurovascular & Neuroradiology Research Unit, Oxford Radcliffe Hospital, Oxford, UK
| |
Collapse
|
20
|
Fujimura S, Takao H, Suzuki T, Uchiyama Y, Tanaka K, Otani K, Ishibashi T, Fukudome K, Mamori H, Yamamoto M, Murayama Y. Blood Flow Analysis in Coil Embolized Aneurysms: Difference between Porous Media and Real Coil Geometry Model. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:1331-1334. [PMID: 30440637 DOI: 10.1109/embc.2018.8512482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
To clarify the mechanism of aneurysmal recanalization, it is necessary to understand the characteristics of the blood flow inside the aneurysm in particular the flow resistance generated by the coil. In studies using computational fluid dynamics (CFD), mainly two approaches have been used to model the coil embolized aneurysm; modeling the coils as porous media or by real coil geometries. In this study, we calculated the pressure drop along a vessel through a coiled region modeled as porous media or by real coil geometry and compared the pressure drop generated by the two coil models. The porous media model was described by Darcy's law and Ergun's equation, while the real coil geometry was generated using finite element method (FEM) structural analysis. We calculated the pressure drop for inlet velocities from 0.1 m/s to 1.0 m/s in steps of 0.1 m/s. Our results indicated that the porous media model may produce larger pressure drops than the real coil geometry model under low packing density. The value of the pressure drop was also changed due to the difference of coil distribution even if the packing density was the same.
Collapse
|