1
|
Lee JY, Kim K, Hwang SI, Lee M, Son K, Kim D, Kim S, Kim YB. Efficacy and safety of transvaginal high-intensity focused ultrasound therapy in women with symptomatic uterine leiomyomas: A clinical trial. Eur J Obstet Gynecol Reprod Biol 2020; 256:302-307. [PMID: 33259999 DOI: 10.1016/j.ejogrb.2020.11.049] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 11/13/2020] [Accepted: 11/15/2020] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To evaluate the efficacy and safety of transvaginal high-intensity focused ultrasound (vHIFU) therapy in women with symptomatic uterine leiomyomas. METHODS This first-in-human, two-center, prospective, unblinded, single-arm trial was performed in the Republic of Korea from December 2017 to February 2019. Premenopausal women with symptomatic, contrast-enhanced uterine leiomyomas with a diameter ≤5 cm were eligible. Under sedation or monitored anesthesia, leiomyomas were ablated with vHIFU under ultrasound guidance. The primary endpoint was the non-perfused volume (NPV) ratio measured immediately after therapy. Secondary endpoints were changes in Uterine Fibroid Symptom-Quality of Life (UFS-QOL) scores, dysmenorrhea visual analog scale (VAS), uterine leiomyoma volume, rate of subsequent therapy, and treatment-emergent adverse events (TEAE). RESULTS Thirty-five women were screened; 13 women were enrolled and underwent vHIFU therapy for 33 uterine leiomyomas. NPV ratios were 0.76 ± 0.27 (mean ± SD); the lower limit of a one-sided 97.5 % confidence interval was 0.67, surpassing the non-inferiority cut-off of 0.50. UFS-QOL scores (symptom severity score, median, baseline: 66.60, 3-month follow-up: 32.85; p = 0.0010; health related quality of life score, median, baseline: 41.40, 3-month follow-up: 73.30; p = 0.0010) and dysmenorrhea VAS (mean, baseline: 50.92, 3-month follow-up: 20.67; p = 0.0019) improved significantly. Volume of uterine leiomyoma was reduced (median, baseline: 8.10 cm3, 3-month follow=-up: 5.30 cm3; p < 0.0001), and none received subsequent therapy. Twenty-six TEAEs from 8 participants were observed, and all TEAEs were resolved without sequelae. CONCLUSION vHIFU therapy exhibited promising efficacy and safety and might be considered as a treatment option for women with symptomatic uterine leiomyomas. Registration: This trial was registered at: www.clinicaltrial.gov (NCT03328260).
Collapse
Affiliation(s)
- Jae Young Lee
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Kidong Kim
- Department of Obstetrics and Gynecology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
| | - Sung Il Hwang
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Maria Lee
- Department of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Keonho Son
- Therapeutic Ultrasound Division, ALPINION Medical Systems, Seoul, Republic of Korea
| | - Daeseung Kim
- Therapeutic Ultrasound Division, ALPINION Medical Systems, Seoul, Republic of Korea
| | - Sun Kim
- Therapeutic Ultrasound Division, ALPINION Medical Systems, Seoul, Republic of Korea
| | - Yong Beom Kim
- Department of Obstetrics and Gynecology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| |
Collapse
|
2
|
Bitton RR, Webb TD, Pauly KB, Ghanouni P. Prolonged heating in nontargeted tissue during MR‐guided focused ultrasound of bone tumors. J Magn Reson Imaging 2019; 50:1526-1533. [DOI: 10.1002/jmri.26726] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 03/08/2019] [Accepted: 03/10/2019] [Indexed: 12/16/2022] Open
Affiliation(s)
- Rachel R. Bitton
- School of Medicine, Department of RadiologyStanford University Stanford California USA
| | - Taylor D. Webb
- Department of Electrical EngineeringStanford University Stanford California USA
| | - Kim Butts Pauly
- School of Medicine, Department of RadiologyStanford University Stanford California USA
| | - Pejman Ghanouni
- School of Medicine, Department of RadiologyStanford University Stanford California USA
| |
Collapse
|
3
|
Yeo SY, Kim YS, Lim HK, Rhim H, Jung SH, Hwang NY. Uterine fibroids: Influence of “T2-Rim sign” on immediate therapeutic responses to magnetic resonance imaging-guided high-intensity focused ultrasound ablation. Eur J Radiol 2017; 97:21-30. [DOI: 10.1016/j.ejrad.2017.10.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 09/28/2017] [Accepted: 10/03/2017] [Indexed: 10/18/2022]
|
4
|
Kim YS, Kim TJ, Lim HK, Rhim H, Jung SH, Ahn JH, Lee JW, Kim BG. Preservation of the endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound ablation of submucosal uterine fibroids. Eur Radiol 2017; 27:3956-3965. [PMID: 28210800 DOI: 10.1007/s00330-017-4765-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Revised: 12/28/2016] [Accepted: 01/23/2017] [Indexed: 12/20/2022]
Abstract
OBJECTIVE To evaluate the integrity of endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of submucosal uterine fibroids based on contrast-enhanced MRI findings, and to identify the risk factors for endometrial impairment. METHODS In total, 117 submucosal fibroids (diameter: 5.9 ± 3.0 cm) in 101 women (age: 43.6 ± 4.4 years) treated with MR-HIFU ablation were retrospectively analysed. Endometrial integrity was assessed with contrast-enhanced T1-weighted images at immediate (n = 101), 3-month (n = 62) and 12-month (n = 15) follow-ups. Endometrial impairment was classified into grades 0 (continuous endometrium), 1 (pin-point, full-thickness discontinuity), 2 (between grade 1 and 3), or 3 (full-thickness discontinuity >1 cm). Risk factors were assessed with generalized estimating equation (GEE) analysis. RESULTS Among 117 fibroids, grades 0, 1, 2 and 3 endometrial impairments were observed at initial examination in 56.4%, 24.8%, 13.7% and 4.3%, respectively. Among 37 fibroid cases of endometrial impairment for which follow-ups were conducted, 30 showed improvements at 3- and/or 12-month follow-up. GEE analysis revealed the degree of endometrial protrusion was significantly associated with severity of endometrial injury (P < 0.0001). CONCLUSIONS After MR-HIFU ablation of submucosal fibroids, endometrial enhancement was preserved intact or minimally impaired in most cases. Impaired endometrium, which is more common after treating endometrially-protruded fibroids, may recover spontaneously. KEY POINTS • After MR-HIFU ablation for submucosal fibroid, endometrium is mostly preserved/minimally impaired. • Endometrial-protruded submucosal fibroid is susceptible to more severe endometrial impairment. • The impaired endometrium may recover spontaneously at follow-up MR exams.
Collapse
Affiliation(s)
- Young-Sun Kim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Radiology, Uterine Fibroid Integrated Management Center, MINT Intervention Hospital, Seoul, Korea
| | - Tae-Joong Kim
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710, Korea.
| | - Hyo Keun Lim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
| | - Hyunchul Rhim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Sin-Ho Jung
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
- Department of Biostatistics and Clinical Epidemiology, Samsung Medical Center, Seoul, Korea
| | - Joong Hyun Ahn
- Biostatistics Team, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea
| | - Jeong-Won Lee
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710, Korea
| | - Byoung-Gie Kim
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710, Korea
| |
Collapse
|
5
|
Screening Magnetic Resonance Imaging-Based Prediction Model for Assessing Immediate Therapeutic Response to Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids. Invest Radiol 2016; 51:15-24. [PMID: 26309184 DOI: 10.1097/rli.0000000000000199] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study was to fit and validate screening magnetic resonance imaging (MRI)-based prediction models for assessing immediate therapeutic responses of uterine fibroids to MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation. MATERIALS AND METHODS Informed consent from all subjects was obtained for our institutional review board-approved study. A total of 240 symptomatic uterine fibroids (mean diameter, 6.9 cm) in 152 women (mean age, 43.3 years) treated with MR-HIFU ablation were retrospectively analyzed (160 fibroids for training, 80 fibroids for validation). Screening MRI parameters (subcutaneous fat thickness [mm], x1; relative peak enhancement [%] in semiquantitative perfusion MRI, x2; T2 signal intensity ratio of fibroid to skeletal muscle, x3) were used to fit prediction models with regard to ablation efficiency (nonperfused volume/treatment cell volume, y1) and ablation quality (grade 1-5, poor to excellent, y2), respectively, using the generalized estimating equation method. Cutoff values for achievement of treatment intent (efficiency >1.0; quality grade 4/5) were determined based on receiver operating characteristic curve analysis. Prediction performances were validated by calculating positive and negative predictive values. RESULTS Generalized estimating equation analyses yielded models of y1 = 2.2637 - 0.0415x1 - 0.0011x2 - 0.0772x3 and y2 = 6.8148 - 0.1070x1 - 0.0050x2 - 0.2163x3. Cutoff values were 1.312 for ablation efficiency (area under the curve, 0.7236; sensitivity, 0.6882; specificity, 0.6866) and 4.019 for ablation quality (0.8794; 0.7156; 0.9020). Positive and negative predictive values were 0.917 and 0.500 for ablation efficiency and 0.978 and 0.600 for ablation quality, respectively. CONCLUSIONS Screening MRI-based prediction models for assessing immediate therapeutic responses of uterine fibroids to MR-HIFU ablation were fitted and validated, which may reduce the risk of unsuccessful treatment.
Collapse
|
6
|
Jeong JH, Hong GP, Kim YR, Ha JE, Lee KS. Clinical Consideration of Treatment to Ablate Uterine Fibroids with Magnetic Resonance Imaging-guided High Intensity Focused Ultrasound (MRgFUS): Sonalleve. J Menopausal Med 2016; 22:94-107. [PMID: 27617244 PMCID: PMC5016510 DOI: 10.6118/jmm.2016.22.2.94] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 07/17/2016] [Accepted: 07/26/2016] [Indexed: 12/18/2022] Open
Abstract
Objectives Magnetic resonance imaging (MRI)-guided high intensity focused ultrasound surgery (MRgFUS) is a newly emerging non-invasive technique for the treatment of uterine fibroids. The purpose of this study is to review the clinical impact of MRgFUS. Methods This study examined 157 patients. The high intensity focused ultrasound (HIFU) utilized in this study was Philips Achieva 1.5 Tesla MR (Philips Healthcare, Best, the Netherlands) and Sonalleve HIFU system. The patients were followed in post-operative Month 1, Month 3, and Month 6 to investigate any change. Then, these were further classified according to the use of uterine stimulant (oxytocin) in parallel, Funaki Type of uterine fibroid, HIFU intensity, and non-perfused volume (NPV) ratio. Results When the uterine stimulant was utilized, the HIFU intensity was measured at significantly lower levels, compared with the group not using uterine stimulant, and treatment duration was significantly. The NPV ratio was found significantly higher in the group using uterine stimulant. Concerning the correlation between Funaki Type of uterine fibroid and average sonication power, it was found that the closer to Type I, the lower the sonication power, the shorter the treatment duration, and the higher the NPV ratio significantly. Conclusions In this study, it was found that the lower the Funaki Types of uterine fibroids, and the higher the NPV ratio immediately after the operation, the larger the uterine fibroid volume decrease and SSS change were. Also, if uterine stimulant was used in parallel in treatment, treatment duration and HIFU intensity could become shorter and lower.
Collapse
Affiliation(s)
- Jae-Hyeok Jeong
- Department of Obstetrics & Gynecology, Hwa Myung Il Sin Christian Hospital, Busan, Korea
| | - Gil Pyo Hong
- Department of Obstetrics & Gynecology, Hwa Myung Il Sin Christian Hospital, Busan, Korea
| | - Yu-Ri Kim
- Department of Obstetrics & Gynecology, Hwa Myung Il Sin Christian Hospital, Busan, Korea
| | - Jae-Eun Ha
- Department of Obstetrics & Gynecology, Hwa Myung Il Sin Christian Hospital, Busan, Korea
| | - Kyu-Sup Lee
- Department of Obstetrics & Gynecology, Pusan National University School of Medicine, Busan, Korea
| |
Collapse
|
7
|
Kim YS, Lim HK, Rhim H. Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids: Effect of Bowel Interposition on Procedure Feasibility and a Unique Bowel Displacement Technique. PLoS One 2016; 11:e0155670. [PMID: 27186881 PMCID: PMC4871469 DOI: 10.1371/journal.pone.0155670] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 05/02/2016] [Indexed: 11/18/2022] Open
Abstract
Purpose To evaluate the effect of bowel interposition on assessing procedure feasibility, and the usefulness and limiting conditions of bowel displacement techniques in magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids. Materials and Methods Institutional review board approved this study. A total of 375 screening MR exams and 206 MR-HIFU ablations for symptomatic uterine fibroids performed between August 2010 and March 2015 were retrospectively analyzed. The effect of bowel interposition on procedure feasibility was assessed by comparing pass rates in periods before and after adopting a unique bowel displacement technique (bladder filling, rectal filling and subsequent bladder emptying; BRB maneuver). Risk factors for BRB failure were evaluated using logistic regression analysis. Results Overall pass rates of pre- and post-BRB periods were 59.0% (98/166) and 71.7% (150/209), and in bowel-interposed cases they were 14.6% (7/48) and 76.4% (55/72), respectively. BRB maneuver was technically successful in 81.7% (49/60). Through-the-bladder sonication was effective in eight of eleven BRB failure cases, thus MR-HIFU could be initiated in 95.0% (57/60). A small uterus on treatment day was the only significant risk factor for BRB failure (B = 0.111, P = 0.017). Conclusion The BRB maneuver greatly reduces the fraction of patients deemed ineligible for MR-HIFU ablation of uterine fibroids due to interposed bowels, although care is needed when the uterus is small.
Collapse
Affiliation(s)
- Young-sun Kim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- * E-mail:
| | - Hyo Keun Lim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Health Science and Technology, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyunchul Rhim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
8
|
Ellens N, Hynynen K. Frequency considerations for deep ablation with high-intensity focused ultrasound: A simulation study. Med Phys 2016; 42:4896-10. [PMID: 26233216 DOI: 10.1118/1.4927060] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
PURPOSE The objective of this study was to explore frequency considerations for large-volume, deep thermal ablations with focused ultrasound. Though focal patterns, focal steering rate, and the size of focal clusters have all been explored in this context, frequency studies have generally explored shallower depths and hyperthermia applications. This study examines both treatment efficiency and near-field heating rate as functions of frequency and depth. METHODS Flat, 150 mm transducer arrays were simulated to operate at frequencies of 250, 500, 750, 1000, 1250, and 1500 kHz. Each array had λ2 interelement spacing yielding arrays of 2000-70 000 piston-shaped elements arranged in concentric rings. Depths of 50, 100, and 150 mm were explored, with attenuation (α) values of 2.5-10 (Np/m)/MHz. Ultrasound propagation was simulated with the Rayleigh-Sommerfeld integral over a volume of homogeneous simulated tissue. Absorbed power density was determined from the acoustic pressure which, in turn, was modeled with the Pennes bioheat transfer equation. Using this knowledge of temperature over time, thermal dose function of Sapareto and Dewey was used to model the resulting bioeffect of each simulated sonication. Initially, single foci at each depth, frequency, and α were examined with either fixed peak temperatures or fixed powers. Based on the size of the resulting, single foci lesions, larger compound sonications were designed with foci packed together in multiple layers and rings. For each depth, focal patterns were chosen to produce a similar total ablated volume for each frequency. These compound sonications were performed with a fixed peak temperature at each focus. The resulting energy efficiency (volume ablated per acoustic energy applied), near-field heating rate (temperature increase in the anterior third of the simulation space per unit volume ablated), and near- and far-field margins were assessed. RESULTS Lesions of comparable volume were created with different frequencies at different depths. The results reflect the interconnected nature of frequency as it effects focal size (decreasing with frequency), peak pressure (generally increasing with frequency), and attenuation (also increasing with frequency). The ablation efficiency was the highest for α = 5 (Np/m)/MHz at a frequency of 750 kHz at each depth. For α = 10 (Np/m)/MHz, efficiency was the highest at 750 kHz for a depth of 50 mm, and 500 kHz at depths of 100 and 150 mm. At all sonication depths, near-field heating was minimized with lower frequencies of 250 and 500 kHz. CONCLUSIONS Large-volume ablations are most efficient at frequencies of 500-750 kHz at depths of 100-150 mm. When one considers that near-field heat accumulation tends to be the rate limiting factor in large-volume ablations like uterine fibroid surgery, the results show that frequencies as low as 500 kHz are favored for their ability to reduce heating in the near-field.
Collapse
Affiliation(s)
- Nicholas Ellens
- Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada and Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G 1L7, Canada
| | - Kullervo Hynynen
- Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada and Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G 1L7, Canada
| |
Collapse
|
9
|
Kim YS, Lee JW, Choi CH, Kim BG, Bae DS, Rhim H, Lim HK. Uterine Fibroids: Correlation of T2 Signal Intensity with Semiquantitative Perfusion MR Parameters in Patients Screened for MR-guided High-Intensity Focused Ultrasound Ablation. Radiology 2016; 278:925-35. [DOI: 10.1148/radiol.2015150608] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
Volumetric MR-Guided High-Intensity Focused Ultrasound with Direct Skin Cooling for the Treatment of Symptomatic Uterine Fibroids: Proof-of-Concept Study. BIOMED RESEARCH INTERNATIONAL 2015; 2015:684250. [PMID: 26413538 PMCID: PMC4568047 DOI: 10.1155/2015/684250] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Accepted: 08/18/2014] [Indexed: 01/26/2023]
Abstract
Objective. To prospectively assess the safety and technical feasibility of volumetric magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation with direct skin cooling (DISC) during treatment of uterine fibroids. Methods. In this proof-of-concept study, eight patients were consecutively selected for clinical MR-HIFU ablation of uterine fibroids with the use of an additional DISC device to maintain a constant temperature (T ≈ 20°C) at the interface between the HIFU table top and the skin. Technical feasibility was verified by successful completion of MR-HIFU ablation. Contrast-enhanced T1-weighted MRI was used to measure the treatment effect (nonperfused volume (NPV) ratio). Safety was evaluated by recording of adverse events (AEs) within 30 days' follow-up. Results. All MR-HIFU treatments were successfully completed in an outpatient setting. The median NPV ratio was 0.56 (IQR [0.27–0.72]). Immediately after treatment, two patients experienced coldness related discomfort which resolved at the same day. No serious (device-related) AEs were reported. Specifically, no skin burns, cold injuries, or subcutaneous edema were observed. Conclusion. This study showed that it is safe and technically feasible to complete a volumetric MR-HIFU ablation with DISC. This technique may reduce the risk of thermal injury to the abdominal wall during MR-HIFU ablation of uterine fibroids. This trial is registered with NTR4189.
Collapse
|
11
|
Kim YS. Advances in MR image-guided high-intensity focused ultrasound therapy. Int J Hyperthermia 2015; 31:225-232. [DOI: 10.3109/02656736.2014.976773] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
|
12
|
Kim YS, Kim BG, Rhim H, Bae DS, Lee JW, Kim TJ, Choi CH, Lee YY, Lim HK. Uterine Fibroids: Semiquantitative Perfusion MR Imaging Parameters Associated with the Intraprocedural and Immediate Postprocedural Treatment Efficiencies of MR Imaging–guided High-Intensity Focused Ultrasound Ablation. Radiology 2014; 273:462-71. [DOI: 10.1148/radiol.14132719] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
Huisman M, Lam MK, Bartels LW, Nijenhuis RJ, Moonen CT, Knuttel FM, Verkooijen HM, van Vulpen M, van den Bosch MA. Feasibility of volumetric MRI-guided high intensity focused ultrasound (MR-HIFU) for painful bone metastases. J Ther Ultrasound 2014; 2:16. [PMID: 25309743 PMCID: PMC4193684 DOI: 10.1186/2050-5736-2-16] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Accepted: 08/25/2014] [Indexed: 12/25/2022] Open
Abstract
Background Magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) has recently emerged as an effective treatment option for painful bone metastases. We describe here the first experience with volumetric MR-HIFU for palliative treatment of painful bone metastases and evaluate the technique on three levels: technical feasibility, safety, and initial effectiveness. Methods In this observational cohort study, 11 consecutive patients (7 male and 4 female; median age, 60 years; age range, 53–86 years) underwent 13 treatments for 12 bone metastases. All patients exhibited persistent metastatic bone pain refractory to the standard of care. Patients were asked to rate their worst pain on an 11-point pain scale before treatment, 3 days after treatment, and 1 month after treatment. Complications were monitored. All data were prospectively recorded in the context of routine clinical care. Response was defined as a ≥2-point decrease in pain at the treated site without increase in analgesic intake. Baseline pain scores were compared to pain scores at 3 days and 1 month using the Wilcoxon signed-rank test. For reporting, the STROBE guidelines were followed. Results No treatment-related major adverse events were observed. At 3 days after volumetric MR-HIFU ablation, pain scores decreased significantly (p = 0.045) and response was observed in a 6/11 (55%) patients. At 1-month follow-up, which was available for nine patients, pain scores decreased significantly compared to baseline (p = 0.028) and 6/9 patients obtained pain response (overall response rate 67% (95% confidence interval (CI) 35%–88%)). Conclusions This is the first study reporting on the volumetric MR-HIFU ablation for painful bone metastases. No major treatment-related adverse events were observed during follow-up. The results of our study showed that volumetric MR-HIFU ablation for painful bone metastases is technically feasible and can induce pain relief in patients with metastatic bone pain refractory to the standard of care. Future research should be aimed at standardization of the treatment procedures and treatment of larger numbers of patients to assess treatment effectiveness and comparison to the standard of care.
Collapse
Affiliation(s)
- Merel Huisman
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, The Netherlands
| | - Mie K Lam
- Image Sciences Institute, University Medical Center Utrecht, 3508 GA Utrecht, The Netherlands
| | - Lambertus W Bartels
- Image Sciences Institute, University Medical Center Utrecht, 3508 GA Utrecht, The Netherlands
| | - Robbert J Nijenhuis
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, The Netherlands
| | - Chrit T Moonen
- Image Sciences Institute, University Medical Center Utrecht, 3508 GA Utrecht, The Netherlands
| | - Floor M Knuttel
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, The Netherlands
| | - Helena M Verkooijen
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, The Netherlands
| | - Marco van Vulpen
- Department of Radiation Oncology, University Medical Center Utrecht, 3508 GA Utrecht, The Netherlands
| | - Maurice A van den Bosch
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, The Netherlands
| |
Collapse
|
14
|
Jeon IR, Park JG, Haney CR, Harris TD. Spin crossover iron(ii) complexes as PARACEST MRI thermometers. Chem Sci 2014. [DOI: 10.1039/c4sc00396a] [Citation(s) in RCA: 81] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
We demonstrate the potential utility of spin crossover iron(ii) complexes as temperature-responsive paramagnetic chemical exchange saturation transfer (PARACEST) contrast agents in magnetic resonance imaging (MRI) thermometry.
Collapse
Affiliation(s)
- Ie-Rang Jeon
- Department of Chemistry
- Northwestern University
- Evanston, USA
| | - Jesse G. Park
- Department of Chemistry
- Northwestern University
- Evanston, USA
| | - Chad R. Haney
- Center for Advanced Molecular Imaging
- Northwestern University
- Evanston, USA
| | | |
Collapse
|