1
|
Sainio T, Saunavaara J, Komar G, Viitala A, Otonkoski S, Joronen K, Perheentupa A, Sequeiros RB. Assessing blood flow in uterine fibroids using intravoxel incoherent motion imaging compared with dynamic contrast-enhanced MRI. Sci Rep 2025; 15:2980. [PMID: 39848947 PMCID: PMC11758379 DOI: 10.1038/s41598-024-83739-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2024] [Accepted: 12/17/2024] [Indexed: 01/25/2025] Open
Abstract
To assess the utility of IVIM parameters in evaluating uterine fibroid blood flow compared to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) derived blood flow. Sixteen premenopausal women with uterine fibroids were enrolled in this prospective study. Pelvic MRI scans were obtained for each subject, both with and without continuous intravenous infusion of oxytocin, known to decrease significantly uterine fibroid blood flow, to assess the changes in blood flow of uterine fibroids. IVIM and DCE analyses were conducted using separate dedicated software. The bi-exponential IVIM model was used to estimate perfusion fraction (f), pseudo-diffusion coefficient (D*), and diffusion coefficient (D). DCE blood flow values were derived via T1 perfusion deconvolution arithmetic, utilizing a first pass of an AIF curve. The correlation between the parameters were analyzed by Spearman's rank correlation analysis due to small sample size. Means of the parameters were compared with a nonparametric Wilcoxon sign rank method for each pair. Statistically significant positive correlations were found between perfusion fraction values and DCE blood flow values with oxytocin (Spearson's ρ = 0.78, p = 0.0004), and between fD* values and DCE blood flow values with oxytocin (Spearson's ρ = 0.64, p = 0.0071). Significant differences in blood flow were detected across most IVIM parameters: f, D*, and fD* (p < 0.001, p = 0.0027, and p = 0.0002, respectively) when comparing the values without oxytocin and with oxytocin. IVIM imaging shows promise for assessing blood flow in uterine fibroids.
Collapse
Affiliation(s)
- Teija Sainio
- Department of Medical Physics, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland.
| | - Jani Saunavaara
- Department of Medical Physics, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland
| | - Gaber Komar
- Department of Radiology, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland
| | - Antti Viitala
- Department of Radiology, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland
| | - Saara Otonkoski
- Department of Obstetrics and Gynecology, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland
| | - Kirsi Joronen
- Department of Obstetrics and Gynecology, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland
| | - Antti Perheentupa
- Department of Obstetrics and Gynecology, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland
| | - Roberto Blanco Sequeiros
- Department of Radiology, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland
| |
Collapse
|
2
|
Shah R, Phatak N, Choudhary A, Gadewar S, Ajazuddin, Bhattacharya S. Exploring the Theranostic Applications and Prospects of Nanobubbles. Curr Pharm Biotechnol 2024; 25:1167-1181. [PMID: 37861011 DOI: 10.2174/0113892010248189231010085827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 09/01/2023] [Accepted: 09/07/2023] [Indexed: 10/21/2023]
Abstract
Anticancer medications as well as additional therapeutic compounds, have poor clinical effectiveness due to their diverse distribution, non-selectivity for malignant cells, and undesirable off-target side effects. As a result, ultrasound-based targeted delivery of therapeutic compounds carried in sophisticated nanocarriers has grown in favor of cancer therapy and control. Nanobubbles are nanoscale bubbles that exhibit unique physiochemical properties in both their inner core and outer shell. Manufacturing nanobubbles primarily aims to enhance therapeutic agents' bioavailability, stability, and targeted delivery. The small size of nanobubbles allows for their extravasation from blood vessels into surrounding tissues and site-specific release through ultrasound targeting. Ultrasound technology is widely utilized for therapy due to its speed, safety, and cost-effectiveness, and micro/nanobubbles, as ultrasound contrast agents, have numerous potential applications in disease treatment. Thus, combining ultrasound applications with NBs has recently demonstrated increased localization of anticancer molecules in tumor tissues with triggered release behavior. Consequently, an effective therapeutic concentration of drugs/genes is achieved in target tumor tissues with ultimately increased therapeutic efficacy and minimal side effects on other non-cancerous tissues. This paper provides a brief overview of the production processes for nanobubbles, along with their key characteristics and potential therapeutic uses.
Collapse
Affiliation(s)
- Rahul Shah
- Department of Pharmaceutics, School of Pharmacy & Technology Management, SVKM'S NMIMS Deemed-to-be University, Shirpur, Maharashtra, 425405, India
| | - Niraj Phatak
- Department of Pharmaceutics, School of Pharmacy & Technology Management, SVKM'S NMIMS Deemed-to-be University, Shirpur, Maharashtra, 425405, India
| | - Ashok Choudhary
- Department of Quality Assurance, School of Pharmacy & Technology Management, SVKM'S NMIMS Deemed-to-be University, Shirpur, Maharashtra, 425405, India
| | - Sakshi Gadewar
- Department of Pharmaceutics, School of Pharmacy & Technology Management, SVKM'S NMIMS Deemed-to-be University, Shirpur, Maharashtra, 425405, India
| | - Ajazuddin
- Department of Pharmaceutics, Rungta College of Pharmaceutical Sciences & Research, Khoka-Kurud Road, Bhilai, Chhattisgarh, 490024, India
| | - Sankha Bhattacharya
- Department of Pharmaceutics, School of Pharmacy & Technology Management, SVKM'S NMIMS Deemed-to-be University, Shirpur, Maharashtra, 425405, India
| |
Collapse
|
3
|
Xu J, Tang W, Lin L, Wang Y, Cheng J. Post treatment and 3 month contrast enhanced MRI findings following HIFU of submucosal fibroids: a retrospective study. Int J Hyperthermia 2023; 40:2216897. [PMID: 37230470 DOI: 10.1080/02656736.2023.2216897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 05/07/2023] [Accepted: 05/17/2023] [Indexed: 05/27/2023] Open
Abstract
PURPOSE This study used contrast-enhanced MRI (CE-MRI) examination to assess the efficacy of high-intensity focused ultrasound (HIFU) for submucosal fibroids. METHODS A total of 81 submucosal fibroids, including 33 cases of type 1, 29 cases of type 2, and 19 cases of type 2-5, treated by HIFU were retrospectively reviewed. CE-MRI was performed in all cases immediately after HIFU, the non-perfused volume ratio (NPVR) and the degree of endometrial impairment were recorded. Thereafter, CE-MRI was repeated in all cases after three months, and the change of fibroid volume shrinkage rate (FVSR), NPVR and the degree of endometrial impairment were recorded. RESULTS The immediate NPVR was 86.4 ± 19.3% in type 1, 90.0 ± 13.3% in type 2 and 90.3 ± 7.2% in type 2-5. Among 81 fibroids, grades 0, 1, 2 and 3 endometrial impairments were observed in 38.3%, 16.1%, 14.8% and 30.9%, respectively. Three months later, NPVR was 68.0 ± 36.4% in type 1, 74.3 ± 27.7% in type 2 and 85.0 ± 16.1% in type 2-5. Grades 0, 1, 2 and 3 endometrial impairments were observed in 64.2%, 23.5%, 9.9% and 2.4%.FVSR was 49.0 ± 1.3% in type 1, 39.6 ± 1.7% in type 2 and 37.2 ± 2.1% in type 2-5. The FVSR in submucosal fibroid type 1 was superior to type 2 and type 2-5 (p < 0.05). The NPVR of submucosal fibroids in type 2-5 were higher than type 1 (p < 0.05) .There was no difference among different types of submucosal fibroids in endometrial impairment (p > 0.05) three months after HIFU. CONCLUSIONS At three months after HIFU, FVSR was better for submucosal fibroid type 1 than for type 2 and type 2-5. And there was no difference in endometrial impairment among the different types of submucosal fibroid groups.
Collapse
Affiliation(s)
- Jialu Xu
- Department of Radliology, Shanghai First Maternity and Infant Hospital, Tongji University, Shanghai, China
| | - Wei Tang
- Department of Radliology, Fudan University Shanghai Cancer Center, Shanghai, China
| | - Lingling Lin
- Department of Radliology, Shanghai Renji Hospital Affiliated to Jiaotong University, Shanghai, China
| | - Yu Wang
- Department of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University, Shanghai, China
| | - Jiejun Cheng
- Department of Radliology, Shanghai First Maternity and Infant Hospital, Tongji University, Shanghai, China
| |
Collapse
|
4
|
Hyvärinen M, Huang Y, David E, Hynynen K. Comparison of computer simulations and clinical treatment results of magnetic resonance-guided focused ultrasound surgery (MRgFUS) of uterine fibroids. Med Phys 2022; 49:2101-2119. [PMID: 34601729 PMCID: PMC9314069 DOI: 10.1002/mp.15263] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 08/31/2021] [Accepted: 08/31/2021] [Indexed: 11/15/2022] Open
Abstract
PURPOSE Magnetic resonance-guided focused ultrasound surgery (MRgFUS) can be used to noninvasively treat symptomatic uterine fibroids by heating with focused ultrasound sonications while monitoring the temperature with magnetic resonance (MR) thermometry. While prior studies have compared focused ultrasound simulations to clinical results, studies involving uterine fibroids remain scarce. In our study, we perform such a comparison to assess the suitability of simulations for treatment planning. METHODS Sonications (N = 67) were simulated retrospectively using acoustic and thermal models based on the Rayleigh integral and Pennes bioheat equation followed by MR-thermometry simulation in seven patients who underwent MRgFUS treatment for uterine fibroids. The spatial accuracy of simulated focus location was assessed by evaluating displacements of the centers of mass of the thermal dose distributions between simulated and treatment MR thermometry slices. Temperature-time curves and sizes of 240 equivalent minutes at 43°C (240EM43 ) volumes between treatment and simulation were compared. RESULTS The simulated focus location showed errors of 2.7 ± 4.1, -0.7 ± 2.0, and 1.3 ± 1.2 mm (mean ± SD) in the anterior-posterior, foot-head, and right-left directions for a fibroid absorption coefficient of 4.9 Np m-1 MHz-1 and perfusion parameter of 1.89 kg m-3 s-1 . Linear regression of 240EM43 volumes of 67 sonications of patient treatments and simulations utilizing these parameters yielded a slope of 1.04 and a correlation coefficient of 0.54. The temperature rise ratio of simulation to treatment near the end of sonication was 0.47 ± 0.22, 1.28 ± 0.60, and 1.49 ± 0.71 for 66 sonications simulated utilizing fibroid absorption coefficient of 1.2, 4.9, and 8.6 Np m-1 MHz-1 , respectively, and the aforementioned perfusion value. The impact of perfusion on peak temperature rise is minimal between 1.89 and 10 kg m-3 s-1 , but became more substantial when utilizing a value of 100 kg m-3 s-1 . CONCLUSIONS The results of this study suggest that perfusion, while in some cases having a substantial impact on thermal dose volumes, has less impact than ultrasound absorption for predicting peak temperature elevation at least when using perfusion parameter values up to 10 kg m-3 s-1 for this particular array geometry, frequencies, and tissue target which is good for clinicians to be aware of. The results suggest that simulations show promise in treatment planning, particularly in terms of spatial accuracy. However, in order to use simulations to predict temperature rise due to a sonication, knowledge of the patient-specific tissue parameters, in particular the absorption coefficient is important. Currently, spatially varying patient-specific tissue parameter values are not available during treatment, so simulations can only be used for planning purposes to estimate sonication performance on average.
Collapse
Affiliation(s)
- Mikko Hyvärinen
- Sunnybrook Research InstituteTorontoOntarioCanada
- Department of Medical BiophysicsUniversity of TorontoTorontoOntarioCanada
| | - Yuexi Huang
- Sunnybrook Research InstituteTorontoOntarioCanada
| | | | - Kullervo Hynynen
- Sunnybrook Research InstituteTorontoOntarioCanada
- Department of Medical BiophysicsUniversity of TorontoTorontoOntarioCanada
| |
Collapse
|
5
|
Role of contrast-enhanced ultrasonography in MR-guided focused ultrasound ablation on uterus fibroids: lesion selection and assessment of ablative effects. Eur Radiol 2021; 32:2110-2119. [PMID: 34751794 DOI: 10.1007/s00330-021-08294-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 07/13/2021] [Accepted: 08/22/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVES To determine whether contrast-enhanced ultrasonography (CEUS) can be used for selecting lesions and assessing the ablative effects of MRgFUS ablation on uterus fibroids, compared with MR imaging. METHODS This retrospective study was approved by the institutional review board of our hospital. From April 2018 to November 2019, a total of 44 symptomatic fibroids in 38 patients who underwent MRgFUS ablation were included. The association between pre-ablation characteristics on CEUS/MR imaging and the non-perfusion volume (NPV) after ablation was analyzed using multivariable linear regression analysis. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve values was compared between the CEUS and MR imaging regression models. NPV after ablation was compared between CEUS and enhanced MR imaging. RESULTS On CEUS, entangled branch vessels, fast-in, and fast-out patterns were significantly associated with NPV, with an AUC of 0.95 (95% CI; 0.88, 1.00). On MR imaging, hyper-intensity on T2-weighted images (T2WI), hyper-intense ring-like signal on T2WI images, and hyper-enhancement on contrast-enhanced T1WI images were correlated with NPV, with an AUC of 0.86 (95% CI; 0.70, 1.00). After ablation, no differences in NPV were noted between contrast-enhanced T1WI (84.13 ± 75.42 cm3) and CEUS (80.22 ± 76.49 cm3). CONCLUSIONS Some pre-ablation characteristics of uterine fibroids on CEUS were associated with NPV after MRgFUS. CEUS may contribute to the evaluation of ablative outcomes and patient selection, similar to MR imaging. KEY POINTS • Contrast-enhanced ultrasonography (CEUS) is effective for selecting the appropriate uterine fibroids before MR-guided focused ultrasound (MRgFUS) ablation and evaluating non-perfusion volumes (NPV) after ablation, as a potential alternative to MR imaging. • Before ablation, entangled branch vessels, fast-in, and fast-out patterns on CEUS were significantly associated with NPV after MRgFUS. • No significant differences in NPV were detected between contrast-enhanced T1WI and CEUS after ablation.
Collapse
|
6
|
Sainio T, Saunavaara J, Komar G, Otonkoski S, Joronen K, Viitala A, Perheentupa A, Blanco Sequeiros R. Feasibility of T2 relaxation time in predicting the technical outcome of MR-guided high-intensity focused ultrasound treatment of uterine fibroids. Int J Hyperthermia 2021; 38:1384-1393. [PMID: 34542013 DOI: 10.1080/02656736.2021.1976850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
PURPOSE The aim of this study was to assess the feasibility of T2 relaxation time in predicting the immediate technical outcome i.e., nonperfused volume ratio (NPVr) of magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) treatment of symptomatic uterine fibroids and to compare it with existing T2-weighted imaging methods (Funaki classification and scaled signal intensity, SSI). MATERIALS AND METHODS 30 patients with 32 uterine fibroids underwent an MRI study including a quantitative T2 relaxation time measurement prior to MRgHIFU treatment. T2 relaxation times were measured with a multi-echo fast imaging-based technique with 16 echoes. The correlation between pretreatment values of the uterine fibroids and treatment outcomes, that is nonperfused volume ratios (NPVr), was assessed with nonparametric statistical measures. T2 relaxation time-based method was compared to existing T2-weighted imaging-based methods using receiver-operating-characteristics (ROC) curve analysis and Chi-square test. RESULTS Nonparametric measures of association revealed a statistically significant negative correlation between T2 relaxation time values and NPVr. The T2 relaxation time classification (T2 I, T2 II, and T2 III) resulted in the whole model p-value of 0.0019, whereas the Funaki classification resulted in a p-value of 0.56. The T2 relaxation time classification (T2 I and T2 II) achieved a whole model of a p-value of 0.0024, whereas the SSI classification had a p-value of 0.0749. CONCLUSIONS A longer T2 relaxation time of the fibroid prior to treatment correlated with a lower NPVr. Based on our results, the T2 relaxation time classifications seem to outperform the Funaki classification and the SSI method.
Collapse
Affiliation(s)
- Teija Sainio
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| | - Jani Saunavaara
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| | - Gaber Komar
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Saara Otonkoski
- Department of Obstetrics and Gynecology, Turku University Hospital, Turku, Finland
| | - Kirsi Joronen
- Department of Obstetrics and Gynecology, Turku University Hospital, Turku, Finland
| | - Antti Viitala
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Antti Perheentupa
- Department of Obstetrics and Gynecology, Turku University Hospital, Turku, Finland
| | | |
Collapse
|
7
|
Gong C, Lin Z, Lv F, Zhang L, Wang Z. Magnetic resonance imaging parameters in predicting the ablative efficiency of high-intensity focused ultrasound for uterine fibroids. Int J Hyperthermia 2021; 38:523-531. [PMID: 33781153 DOI: 10.1080/02656736.2021.1904152] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
OBJECTIVE To evaluate the role of quantitative MRI parameters in predicting HIFU ablation results for uterine fibroids. MATERIAL AND METHODS A total of 245 patients with uterine fibroids who underwent HIFU treatment in Chongqing Haifu Hospital were reviewed retrospectively. The patients were divided into two groups according to the non-perfused volume (NPV) ratio which was either higher or lower than 80%. The MRI parameters were measured, and a logistical regression analysis was performed to investigate the potential predictors associated with the NPV ratio. Receiver operating characteristics (ROC) analysis was used to determine the cut off value for MRI parameters in predicting a high NPV ratio. RESULTS The subcutaneous fat thickness in the group of patients with an NPV ratio over 80% was significantly thinner than that in the group of patients with an NPV ratio less than 80% (15 mm versus 21 mm). The signal intensity ratio of fibroids to skeletal muscle on T2WI was significantly lower in the group of patients with an NPV ratio over 80% compared with the group with an NPV ratio lower than 80% (2.46 versus 3.23). The signal intensity ratio of fibroid to skeletal muscle correlated negatively with the NPV ratio and positively with the energy efficiency factor (EEF). The cut off value of signal intensity ratio of fibroid to muscle for predicting the NPV ratio over 80% is 3.045. CONCLUSION The signal intensity ratio of fibroid to skeletal muscle on T2WI can be used as a factor for predicting the effectiveness of HIFU ablation of uterine fibroids.
Collapse
Affiliation(s)
- Chunmei Gong
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Zhenjiang Lin
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Fajin Lv
- Department of Radiology, First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Lian Zhang
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Zhibiao Wang
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| |
Collapse
|
8
|
Sainio T, Saunavaara J, Komar G, Mattila S, Otonkoski S, Joronen K, Perheentupa A, Blanco Sequeiros R. Feasibility of apparent diffusion coefficient in predicting the technical outcome of MR-guided high-intensity focused ultrasound treatment of uterine fibroids - a comparison with the Funaki classification. Int J Hyperthermia 2021; 38:85-94. [PMID: 33506700 DOI: 10.1080/02656736.2021.1874545] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
PURPOSE To investigate the feasibility of using an apparent diffusion coefficient (ADC) classification in predicting the technical outcome of magnetic resonance imaging-guided high-intensity focused ultrasound (MRgHIFU) treatment of symptomatic uterine fibroids and to compare it to the Funaki classification. MATERIALS AND METHODS Forty-two patients with forty-eight uterine fibroids underwent diffusion-weighted imaging (DWI) before MRgHIFU treatment. The DW images were acquired with five different b-values. Correlations between ADC values and treatment parameters were assessed. Optimal ADC cutoff values were determined to predict technical outcomes, that is, nonperfused volume ratios (NPVr) such that three classification groups were created (NPVr of <30%, 30-80%, or >80%). Results were compared to the Funaki classification using receiver-operating-characteristic (ROC) curve analysis, with statistical significance being tested with the Chi-square test. RESULTS A statistically significant negative correlation (Spearman's ρ = -0.31, p-value < 0.05) was detected between ADC values and NPV ratios. ROC curve analysis indicated that optimal ADC cutoff values of 980 × 10-6mm2/s (NPVr > 80%) and 1800 × 10-6mm2/s (NPVr < 30%) made it possible to classify fibroids into three groups: ADC I (NPVr > 80%), ADC II (NPVr 30-80%) and ADC III (NPVr < 30%). Analysis of the whole model area under the curve resulted in values of 0.79 for the ADC classification (p-value = 0.0007) and 0.62 for the Funaki classification (p-value = 0.0527). CONCLUSIONS Lower ADC values prior to treatment correlate with higher NPV ratios. The ADC classification seems to be able to predict the NPV ratio and may even outperform the Funaki classification. Based on these results DWI and ADC maps should be included in the MRI screening protocol.
Collapse
Affiliation(s)
- Teija Sainio
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| | - Jani Saunavaara
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| | - Gaber Komar
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Sami Mattila
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| | - Saara Otonkoski
- Department of Obstetrics and Gynecology, Turku University Hospital, Turku, Finland
| | - Kirsi Joronen
- Department of Obstetrics and Gynecology, Turku University Hospital, Turku, Finland
| | - Antti Perheentupa
- Department of Obstetrics and Gynecology, Turku University Hospital, Turku, Finland
| | | |
Collapse
|
9
|
Ierardi AM, Carnevale A, Pellegrino F, Stefano GD, Bonelli C, Renzulli M, Giganti M, Carrafiello G. Uterine Myomas: Extravascular Treatment. Semin Ultrasound CT MR 2020; 42:56-74. [PMID: 33541590 DOI: 10.1053/j.sult.2020.08.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Uterine fibroids are common benign tumors that affect the female reproductive tract. They are responsible for considerable morbidity and deterioration of life quality. The main advantages offered by mini invasive techniques are low grade of invasiveness and short times of hospitalization. The most diffuse technique is uterine artery embolization (UAE). Common concerns with UAE include postprocedural pain, postembolization syndrome, and risk of infection. Image-guided thermal ablation techniques like radiofrequency ablation, percutaneous microwave ablation, and imaging-guided high-intensity focused ultrasound were introduced to overcome the side effects related to UAE and surgery. The aim of this review is to briefly analyze the ablative procedures and their role in the management of symptomatic fibroids, and to describe the safety profile and outcomes of these modalities.
Collapse
Affiliation(s)
- Anna Maria Ierardi
- Radiology Unit, Foundation IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy.
| | - Aldo Carnevale
- Department of Morphology, Surgery and Experimental Medicine, Section of Radiology, University of Ferrara, Ferrara, Italy
| | - Fabio Pellegrino
- Department of Morphology, Surgery and Experimental Medicine, Section of Radiology, University of Ferrara, Ferrara, Italy
| | - Giuseppina Di Stefano
- Department of Morphology, Surgery and Experimental Medicine, Section of Radiology, University of Ferrara, Ferrara, Italy
| | - Cristian Bonelli
- Healthcare Professional Department, Foundation IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Matteo Renzulli
- Radiology Unit, Department of Experimental, Diagnostic and Speciality Medicine, Sant'Orsola Hospital, University of Bologna, Bologna, Italy
| | - Melchiore Giganti
- Department of Morphology, Surgery and Experimental Medicine, Section of Radiology, University of Ferrara, Ferrara, Italy
| | - Gianpaolo Carrafiello
- Radiology Unit, Foundation IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy
| |
Collapse
|
10
|
Li C, Jin C, Liang T, Li X, Wang R, Zhang Y, Yang J. Magnetic resonance-guided high-intensity focused ultrasound of uterine fibroids: whole-tumor quantitative perfusion for prediction of immediate ablation response. Acta Radiol 2020; 61:1125-1133. [PMID: 31779469 PMCID: PMC7406966 DOI: 10.1177/0284185119891692] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
Background In magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of uterine fibroids, the immediate ablation response is significantly affected by blood perfusion. The variability of measurement for blood perfusion is critical due to the inherent non-uniformity of tumor perfusion and its dependence on reproducible region of interest (ROI) placement. Purpose To investigate the value of whole-tumor ROI (ROIwt) analysis for quantitative perfusion in predicting immediate ablation response of uterine fibroids in MR-HIFU. Material and Methods Thirty-one fibroids in 28 eligible patients were treated with MR-HIFU. Quantitative perfusion parameters (Ktrans, Kep, and Vp) derived from dynamic contrast-enhanced MRI were obtained before MR-HIFU treatment. The ROIwt and single-layer ROI (ROIsl) were used for quantitative perfusion analysis. T1 contrast-enhanced MRI immediately after MR-HIFU treatment was conducted to determine the non-perfused volume ratio (NPVR). Intraclass correlation coefficient (ICC) was used for consistency test. Spearman’s correlation and multivariate linear regression were used to investigate the predictors of the NPVR. Received operating characteristic (ROC) curve was used to test the predictive efficacy of quantitative perfusion parameter. Results The intra- and inter-observer ICC of the quantitative perfusion parameters from ROIwt were higher than those from ROIsl. Multivariate analysis showed that the Ktrans of ROIwt was a predictor of the immediate ablation response. ROC analysis displayed that the AUC of Ktrans of ROIwt is 0.817 in predicting the ablation response. Conclusion Pretreatment Ktrans of ROIwt is more reliable and stable than that of ROIsl. It could be a predictor for the immediate ablation response of uterine fibroids in MR-HIFU.
Collapse
Affiliation(s)
- Chenxia Li
- Department of Biomedical Engineering, the Key Laboratory of Biomedical Information Engineering of the Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University. Xi’an, PR China
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University. Xi’an, PR China
| | - Chao Jin
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University. Xi’an, PR China
| | - Ting Liang
- Department of Biomedical Engineering, the Key Laboratory of Biomedical Information Engineering of the Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University. Xi’an, PR China
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University. Xi’an, PR China
| | - Xiang Li
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University. Xi’an, PR China
| | - Rong Wang
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University. Xi’an, PR China
| | - Yuelang Zhang
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University. Xi’an, PR China
| | - Jian Yang
- Department of Biomedical Engineering, the Key Laboratory of Biomedical Information Engineering of the Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University. Xi’an, PR China
- Department of Radiology, The First Affiliated Hospital of Xi’an Jiaotong University. Xi’an, PR China
| |
Collapse
|
11
|
Qu Y, Xiao Z, Liu L, Lv F, Sheng B, Li J. Uterine Peristalsis Before and After Ultrasound-Guided High-Intensify Focused Ultrasound (USgHIFU) Treatment for Symptomatic Uterine Fibroids. Med Sci Monit 2019; 25:2553-2560. [PMID: 30955023 PMCID: PMC6698095 DOI: 10.12659/msm.913392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Background This study investigated uterine peristalsis before and after ultrasound-guided high-intensify focused ultrasound (USgHIFU) treatment for symptomatic uterine fibroids by cine magnetic resonance imaging (cine MRI). Material/Methods A total of 30 patients with symptomatic uterine fibroids were treated by USgHIFU, who were subjected to cine MRI before and after USgHIFU treatment in the periovulatory phase. The images were analyzed for the existence, direction, and frequency of uterine peristalsis. The effects of uterine volume, the largest fibroid volume and location, and the fibroid number were examined before and after USgHIFU treatment. Results The incidence of uterine peristalsis was significantly increased after USgHIFU treatment. The main direction of uterine peristalsis before and after USgHIFU was cervix-to-fundus. In 12 cases, uterine peristalsis newly emerged after USgHIFU, and the largest fibroid volumes in these 12 cases were significantly smaller than in the remaining 18 cases before and after USgHIFU. The reduction rates of the largest fibroid volume in the 12 cases were significantly higher than in the remaining 18 cases. The largest fibroids were mainly located in the intramural area before and after USgHIFU. Conclusions USgHIFU treatment may contribute to the recovery of uterine peristalsis in patients with symptomatic fibroids, as detected by cine MRI. Uterine peristalsis recovery was related to the largest fibroid volume, especially for intramural fibroids.
Collapse
Affiliation(s)
- Yalin Qu
- Department of Radiology, Chongqing Dazu District People's Hospital, Chongqing, China (mainland)
| | - Zhibo Xiao
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China (mainland)
| | - Liuheng Liu
- Department of Radiology, Chongqing Traditional Chinese Medicine Hospital, Chongqing, China (mainland)
| | - Furong Lv
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China (mainland)
| | - Bo Sheng
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China (mainland)
| | - Jia Li
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China (mainland)
| |
Collapse
|
12
|
Multiparametric MRI Characterization of Funaki Types of Uterine Fibroids Considered for MR-Guided High-Intensity Focused Ultrasound (MR-HIFU) Therapy. Acad Radiol 2019; 26:e9-e17. [PMID: 30064919 DOI: 10.1016/j.acra.2018.05.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 05/09/2018] [Accepted: 05/19/2018] [Indexed: 01/12/2023]
Abstract
RATIONALE AND OBJECTIVES To compare quantitative multiparametric magnetic resonance imaging (mpMRI) data of symptomatic uterine fibroids being considered for MR-guided high-intensity focused ultrasound ablation with fibroid characterization based on the Funaki Classification scheme. MATERIALS AND METHODS This was a prospective, Institutional Review Board -approved, Health Insurance Portability, and Accountability Act-compliant study. Informed consent was obtained. From December 2013 to April 2015, 48 women with symptomatic fibroids underwent screening with mpMRI protocol including sagittal/axial T2-weighted fast spin-echo, sagittal diffusion-weighted, and sagittal dynamic contrast-enhanced 3D T1-weighted gradient echo imaging on a 3T magnet. All fibroids were assigned Funaki type 1, 2, or 3 based on T2-weighted imaging. Differences in size, perfusion, and diffusion/intravoxel incoherent motion parameters among the three Funaki types were determined using linear mixed model. A logistic regression analysis was performed to select the best model in predicting type 3 fibroids. RESULTS A total of 100 fibroids were assessed (20 type 1, 66 type 2, and 14 type 3). Apparent diffusion coefficient and D of type 3 fibroids were significantly higher than those of type 1 (P < 0.0001, P < 0.0001) and 2 fibroids (P = 0.004, P < 0.0001) respectively. Transfer constant of type 3 fibroids was significantly higher than type 1 (P = 0.0357), but not than type 2 (P = 0.0752). A cutoff value of D = 1 × 10-3 mm2/s offers an accuracy, sensitivity, and specificity of 76%, 71%, and 77%, respectively, for the diagnosis of Funaki 3 fibroids. CONCLUSION mpMRI-derived quantitative parameters may enable a more objective selection of patients prior to MR-guided high-intensity focused ultrasound therapy.
Collapse
|
13
|
Sadick M, Richers J, Tuschy B, Schad LR, Schoenberg SO, Zöllner FG. Feasibility of quantitative MR-perfusion imaging to monitor treatment response after uterine artery embolization (UAE) in symptomatic uterus fibroids. Magn Reson Imaging 2019; 59:31-38. [PMID: 30807812 DOI: 10.1016/j.mri.2019.02.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 02/14/2019] [Accepted: 02/15/2019] [Indexed: 01/06/2023]
Abstract
INTRODUCTION In 25% of women, symptomatic uterus myomas are diagnosed with clinical and functional impairment ranging from abdominal and pelvic pain to dys- and hypermenorrhea, dyspareunia, pollakiuria and infertility. Women undergoing a treatment increasingly prefer nowadays minimal invasive, uterus preserving therapies like uterine artery embolization (UAE) over surgical hysterectomy, nowadays. To emphasize the efficacy of UAE as a uterus preserving treatment with targeted therapy of myomas only, analysis of tissue perfusion pre and post embolization is required. The purpose of this study was to assess treatment response in UAE in females with symptomatic uterus myomas by quantitative magnetic resonance perfusion imaging. METHODS Seven females scheduled for uterus myoma embolization underwent three MRI examinations (pre, post, follow-up) including morphological and dynamic contrast enhanced perfusion imaging at 3 T. To measure tumor volume, regions-of-interest covering the tumor and the uterus were drawn by two readers in consensus. Blood flow, blood volume, and mean transit time were calculated by a pixel-by-pixel deconvolution approach. Kruskal-Wallis/Friedman test was employed to test whether the group medians differ significantly with correction for multiple comparisons using Bonferroni method. RESULTS Change of volume could be observed in all patients after embolization but was significantly different only between pre/post and follow-up time point. Measured differences in all perfusion parameters were significant between pre-intervention and post-intervention/follow-up in the myomas, no significant differences could be detected for the uterus tissue. CONCLUSIONS Our results demonstrate devascularization of symptomatic myomas which correlates with cessation of hypermenorrhea in all treated patients without affecting healthy uterus tissue. Supplementing UAE with perfusion imaging to monitor early treatment response is feasible and might provide valuable information for the follow-up of patients and contribute to providing confidence for the patients in treatment success.
Collapse
Affiliation(s)
- Maliha Sadick
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer Ufer 1-3, 68167 Mannheim, Germany
| | - Jakob Richers
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer Ufer 1-3, 68167 Mannheim, Germany
| | - Benjamin Tuschy
- Department of Gynaecology and Obstetrics, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer Ufer 1-3, 68167 Mannheim, Germany
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer Ufer 1-3, 68167 Mannheim, Germany
| | - Stefan O Schoenberg
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer Ufer 1-3, 68167 Mannheim, Germany
| | - Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer Ufer 1-3, 68167 Mannheim, Germany.
| |
Collapse
|
14
|
Keserci B, Duc NM. Magnetic Resonance Imaging Parameters in Predicting the Treatment Outcome of High-intensity Focused Ultrasound Ablation of Uterine Fibroids With an Immediate Nonperfused Volume Ratio of at Least 90. Acad Radiol 2018. [PMID: 29525424 DOI: 10.1016/j.acra.2018.01.022] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
RATIONALE AND OBJECTIVES We aimed to investigate the role of magnetic resonance imaging parameters in predicting the treatment outcome of high-intensity focused ultrasound (HIFU) ablation of uterine fibroids with a nonperfused volume (NPV) ratio of at least 90%. MATERIAL AND METHODS A total of 120 women who underwent HIFU treatment were divided into groups 1 (n = 72) and 2 (n = 48), comprising patients with an NPV ratio of at least 90% and less than 90%, respectively. Multivariate logistic regression analyses were carried out to investigate the potential predictors of the NPV ratio of at least 90%. The NPV ratios immediately post-treatment, therapeutic efficacy at 6 months' follow-up, and safety in terms of adverse effects and changes in anti-Mullerian hormone level were assessed. RESULTS By introducing multiple predictors obtained from multivariate analyses into a generalized estimating equation model, the results showed that the thickness of the subcutaneous fat layer in the anterior abdominal wall, peak enhancement of fibroid, time to peak of fibroid, and the ratio of area under the curve of fibroid to myometrium were statistically significant, except T2 signal intensity ratio of fibroid to myometrium, hence predicting an NPV ratio of at least 90%. No serious adverse effects and no significant difference between the anti-Mullerian hormone levels before or 6 months post-treatment were reported. CONCLUSIONS The findings in this study suggest that the achievement of NPV ratio of at least 90% in magnetic resonance imaging-guided HIFU treatment of uterine fibroids based on prediction model appears clinically possible without compromising the safety of patients.
Collapse
Affiliation(s)
- Bilgin Keserci
- Department of Radiology, Pham Ngoc Thach University of Medicine, 86/2 Thanh Thai, Ward 12, District 10, Ho Chi Minh city, Viet Nam.
| | - Nguyen Minh Duc
- Department of Radiology, Pham Ngoc Thach University of Medicine, 86/2 Thanh Thai, Ward 12, District 10, Ho Chi Minh city, Viet Nam
| |
Collapse
|
15
|
Duc NM, Keserci B. Review of influential clinical factors in reducing the risk of unsuccessful MRI-guided HIFU treatment outcome of uterine fibroids. Diagn Interv Radiol 2018; 24:283-291. [PMID: 30211682 PMCID: PMC6135061 DOI: 10.5152/dir.2018.18111] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 04/17/2018] [Accepted: 04/18/2018] [Indexed: 12/28/2022]
Abstract
Magnetic resonance imaging-guided high-intensity focused ultrasound (MRI-guided HIFU) is an effective noninvasive treatment option for symptomatic uterine fibroids. However, tissue characteristics of uterine fibroids and technical limitations can limit the patient population that can benefit from this therapy. In this article, we present our literature review focusing on the influential clinical factors that might reduce the risk of an unsuccessful MRI-guided HIFU treatment outcome of uterine fibroids.
Collapse
Affiliation(s)
- Nguyen Minh Duc
- Department of Radiology, Pham Ngoc Thach University of Medicine, Ho Chi Minh city, Viet Nam
| | - Bilgin Keserci
- Department of Radiology, Pham Ngoc Thach University of Medicine, Ho Chi Minh city, Viet Nam
| |
Collapse
|
16
|
Liu H, Zhou M, Sheng Z, Chen Y, Yeh CK, Chen W, Liu J, Liu X, Yan F, Zheng H. Theranostic nanosensitizers for highly efficient MR/fluorescence imaging-guided sonodynamic therapy of gliomas. J Cell Mol Med 2018; 22:5394-5405. [PMID: 30156368 PMCID: PMC6201228 DOI: 10.1111/jcmm.13811] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2018] [Revised: 06/25/2018] [Accepted: 06/29/2018] [Indexed: 12/22/2022] Open
Abstract
Glioma is the most frequent primary brain tumour of the central nervous system. Its high aggressiveness and deep‐seated brain lesion make it a great challenge to develop a non‐invasive, precise and effective treatment approach. Here, we report a multifunctional theranostic agent that can integrate imaging and therapy into a single nano‐platform for imaging‐guided sonodynamic therapy (SDT). The SDT agents were fabricated by encapsulation of sinoporphyrin sodium (DVDMS) chelating with manganese ions into nanoliposomes (DVDMS‐Mn‐LPs). DVDMS‐Mn‐LPs are physiologically stable and biologically compatible, and they can produce singlet oxygen upon ultrasound irradiation to kill cancer cells. Both cell and animal studies demonstrated that SDT with DVDMS‐Mn‐LPs can significantly improve the antitumour growth efficiency even in the presence of skull. In addition, DVDMS‐Mn‐LPs are good for MR and fluorescence imaging. Thus, DVDMS‐Mn‐LPs reported here may provide a promising strategy for imaging‐guided modality for glioma treatment.
Collapse
Affiliation(s)
- Hongmei Liu
- Department of Ultrasonography, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Meijun Zhou
- Department of Ultrasonography, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Zonghai Sheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yu Chen
- State Key Laboratory of High Performance Ceramic and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, China
| | - Chih-Kuang Yeh
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Taiwan
| | - Wenting Chen
- School of Life Science and Engineering, Southwest University of Science and Technology, Mianyang, China
| | - Jia Liu
- Department of Ultrasonography, Guangdong Provincial Hospital of Chinese Medicine, The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xin Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Fei Yan
- Department of Ultrasonography, Guangdong Second Provincial General Hospital, Guangzhou, China.,Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Department of Ultrasonography, Guangdong Second Provincial General Hospital, Guangzhou, China.,Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
17
|
Shen S, Li Y, Xiao Y, Zhao Z, Zhang C, Wang J, Li H, Liu F, He N, Yuan Y, Lu Y, Guo S, Wang Y, Liao W, Liao Y, Chen Y, Bin J. Folate-conjugated nanobubbles selectively target and kill cancer cells via ultrasound-triggered intracellular explosion. Biomaterials 2018; 181:293-306. [PMID: 30096563 DOI: 10.1016/j.biomaterials.2018.07.030] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2018] [Revised: 07/18/2018] [Accepted: 07/18/2018] [Indexed: 01/01/2023]
Abstract
With the rapid development of cancer-targeted nanotechnology, a variety of nanoparticle-based drug delivery systems have clinically been employed in cancer therapy. However, multidrug resistance significantly impacts the therapeutic efficacy. Physical non-drug therapy has emerged as a new and promising strategy. This study aimed to determine whether novel folate-nanobubbles (F-NBs), combined with therapeutic ultrasound (US), could act as a safe and effective physical targeted cancer therapy. Using folate-conjugated N-palmitoyl chitosan (F-PLCS), we developed novel F-NBs and characterised their physicochemical properties, internalization mechanism, targeting ability, therapeutic effects, and killing mechanism. The results showed that the novel F-NBs selectively accumulated in FR-positive endothelial cells and tumour cells via FR coupled with clathrin- and caveolin-mediated endocytosis in vitro and in vivo. In addition, the F-NBs killed target cells by an intracellular explosion under US irradiation. Hoechst/PI staining demonstrated that apoptosis and necrosis accounted for a large proportion of cell death in vivo. F-NBs combined with US therapy significantly inhibited tumour growth and improved the overall survival of tumour-bearing mice. Under US irradiation, the novel F-NBs selectively killed FR-positive tumour cells in vitro and in vivo via intracellular explosion and therefore is a promising alternative for targeted cancer treatment.
Collapse
Affiliation(s)
- Shuxin Shen
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China; Department of Cardiology, People's Hospital of Zhengzhou University, Zhengzhou, 450003, China
| | - Ying Li
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China; Department of Critical Care Medicine, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350005, China
| | - Yunbin Xiao
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Zonglei Zhao
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Chuanxi Zhang
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Junfen Wang
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Hairui Li
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Feng Liu
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Nvqin He
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Ye Yuan
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Yongkang Lu
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Shengcun Guo
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Yan Wang
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Wangjun Liao
- Department of Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Yulin Liao
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China
| | - Yanmei Chen
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China.
| | - Jianping Bin
- State Key Laboratory of Organ Failure Research, Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China.
| |
Collapse
|
18
|
Yeo SY, Kim YS, Lim HK, Rhim H, Jung SH, Hwang NY. Uterine fibroids: Influence of “T2-Rim sign” on immediate therapeutic responses to magnetic resonance imaging-guided high-intensity focused ultrasound ablation. Eur J Radiol 2017; 97:21-30. [DOI: 10.1016/j.ejrad.2017.10.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 09/28/2017] [Accepted: 10/03/2017] [Indexed: 10/18/2022]
|
19
|
Pelvic Blood Flow Predicts Fibroid Volume and Embolic Required for Uterine Fibroid Embolization: A Pilot Study With 4D Flow MR Angiography. AJR Am J Roentgenol 2017; 210:189-200. [PMID: 29090998 DOI: 10.2214/ajr.17.18127] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
OBJECTIVE We report here an initial experience using 4D flow MRI in pelvic imaging-specifically, in imaging uterine fibroids. We hypothesized that blood flow might correlate with fibroid volume and that quantifying blood flow might help to predict the amount of embolic required to achieve stasis at subsequent uterine fibroid embolization (UFE). MATERIALS AND METHODS Thirty-three patients with uterine fibroids and seven control subjects underwent pelvic MRI with 4D flow imaging. Of the patients with fibroids, 10 underwent 4D flow imaging before UFE and seven after UFE; in the remaining 16 patients with fibroids, UFE had yet to be performed. Four-dimensional flow measurements were performed using Arterys CV Flow. The flow fraction of the internal iliac artery was expressed as the ratio of internal iliac artery flow to external iliac artery flow and was compared between groups. The flow ratios between the internal iliac arteries on each side were calculated. Fibroid volume versus internal iliac flow fraction, embolic volume versus internal iliac flow fraction, and embolic volume ratio between sides versus the ratio of internal iliac artery flows between sides were compared. RESULTS The mean internal iliac flow fraction was significantly higher in the 26 patients who underwent imaging before UFE (mean ± standard error, 0.78 ± 0.06) than in the seven patients who underwent imaging after UFE (0.48 ± 0.07, p < 0.01) and in the seven control patients without fibroids (0.48 ± 0.08, p < 0.0001). The internal iliac flow fraction correlated well with fibroid volumes before UFE (r = 0.7754, p < 0.0001) and did not correlate with fibroid volumes after UFE (r = -0.3051, p = 0.51). The ratio of embolic required to achieve stasis between sides showed a modest correlation with the ratio of internal iliac flow (r = 0.6776, p = 0.03). CONCLUSION Internal iliac flow measured by 4D flow MRI correlates with fibroid volume and is predictive of the ratio of embolic required to achieve stasis on each side at subsequent UFE and may be useful for preprocedural evaluation of patients with uterine fibroids.
Collapse
|
20
|
Silberzweig JE, Powell DK, Matsumoto AH, Spies JB. Management of Uterine Fibroids: A Focus on Uterine-sparing Interventional Techniques. Radiology 2017; 280:675-92. [PMID: 27533290 DOI: 10.1148/radiol.2016141693] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Uterine fibroids occur in approximately 50% of women over the age of 40 years, and an estimated 50% of those are symptomatic. Menorrhagia is the most common symptom and the primary indication for treatment, although bulk symptoms often occur and can be treated. Pharmacotherapy is typically inadequate unless it can be expected to successfully bridge to menopause or allow for a less-invasive intervention. However, hormonal therapies have risks. Hysterectomy is still the most commonly performed procedure for symptomatic fibroids and has the lowest rate of reintervention (compared with myomectomy or uterine artery embolization [UAE]), but rates of more serious complications are higher and patient satisfaction and ability to return to normal activities may also be less favorable. Myomectomy is not necessarily less morbid than hysterectomy and may have a greater failure rate than UAE. Techniques and devices vary with little standardization, and operator experience is crucial to success. The largest studies of UAE show very low rates of serious complications and rapid recovery. UAE significantly improves symptoms related to uterine fibroids in 85%-90% of patients. Herein, this article will discuss the nature of fibroids and their diagnosis, pharmacotherapy, surgical treatment, and nonsurgical interventional treatment, including UAE and magnetic resonance-guided focused ultrasound. (©) RSNA, 2016.
Collapse
Affiliation(s)
- James E Silberzweig
- From the Department of Radiology, Mount Sinai Beth Israel, New York, NY (J.E.S.); West Cancer Center, University of Tennessee Health Science Center, 7945 Wolf River Boulevard, Germantown, TN 38138 (D.K.P.); Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Va (A.H.S.); and Department of Radiology, MedStar Georgetown University Hospital, Washington, DC (J.B.S.)
| | - Daniel K Powell
- From the Department of Radiology, Mount Sinai Beth Israel, New York, NY (J.E.S.); West Cancer Center, University of Tennessee Health Science Center, 7945 Wolf River Boulevard, Germantown, TN 38138 (D.K.P.); Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Va (A.H.S.); and Department of Radiology, MedStar Georgetown University Hospital, Washington, DC (J.B.S.)
| | - Alan H Matsumoto
- From the Department of Radiology, Mount Sinai Beth Israel, New York, NY (J.E.S.); West Cancer Center, University of Tennessee Health Science Center, 7945 Wolf River Boulevard, Germantown, TN 38138 (D.K.P.); Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Va (A.H.S.); and Department of Radiology, MedStar Georgetown University Hospital, Washington, DC (J.B.S.)
| | - James B Spies
- From the Department of Radiology, Mount Sinai Beth Israel, New York, NY (J.E.S.); West Cancer Center, University of Tennessee Health Science Center, 7945 Wolf River Boulevard, Germantown, TN 38138 (D.K.P.); Department of Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Va (A.H.S.); and Department of Radiology, MedStar Georgetown University Hospital, Washington, DC (J.B.S.)
| |
Collapse
|
21
|
Kim YS, Kim TJ, Lim HK, Rhim H, Jung SH, Ahn JH, Lee JW, Kim BG. Preservation of the endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound ablation of submucosal uterine fibroids. Eur Radiol 2017; 27:3956-3965. [PMID: 28210800 DOI: 10.1007/s00330-017-4765-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Revised: 12/28/2016] [Accepted: 01/23/2017] [Indexed: 12/20/2022]
Abstract
OBJECTIVE To evaluate the integrity of endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of submucosal uterine fibroids based on contrast-enhanced MRI findings, and to identify the risk factors for endometrial impairment. METHODS In total, 117 submucosal fibroids (diameter: 5.9 ± 3.0 cm) in 101 women (age: 43.6 ± 4.4 years) treated with MR-HIFU ablation were retrospectively analysed. Endometrial integrity was assessed with contrast-enhanced T1-weighted images at immediate (n = 101), 3-month (n = 62) and 12-month (n = 15) follow-ups. Endometrial impairment was classified into grades 0 (continuous endometrium), 1 (pin-point, full-thickness discontinuity), 2 (between grade 1 and 3), or 3 (full-thickness discontinuity >1 cm). Risk factors were assessed with generalized estimating equation (GEE) analysis. RESULTS Among 117 fibroids, grades 0, 1, 2 and 3 endometrial impairments were observed at initial examination in 56.4%, 24.8%, 13.7% and 4.3%, respectively. Among 37 fibroid cases of endometrial impairment for which follow-ups were conducted, 30 showed improvements at 3- and/or 12-month follow-up. GEE analysis revealed the degree of endometrial protrusion was significantly associated with severity of endometrial injury (P < 0.0001). CONCLUSIONS After MR-HIFU ablation of submucosal fibroids, endometrial enhancement was preserved intact or minimally impaired in most cases. Impaired endometrium, which is more common after treating endometrially-protruded fibroids, may recover spontaneously. KEY POINTS • After MR-HIFU ablation for submucosal fibroid, endometrium is mostly preserved/minimally impaired. • Endometrial-protruded submucosal fibroid is susceptible to more severe endometrial impairment. • The impaired endometrium may recover spontaneously at follow-up MR exams.
Collapse
Affiliation(s)
- Young-Sun Kim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Radiology, Uterine Fibroid Integrated Management Center, MINT Intervention Hospital, Seoul, Korea
| | - Tae-Joong Kim
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710, Korea.
| | - Hyo Keun Lim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
| | - Hyunchul Rhim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Sin-Ho Jung
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
- Department of Biostatistics and Clinical Epidemiology, Samsung Medical Center, Seoul, Korea
| | - Joong Hyun Ahn
- Biostatistics Team, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Korea
| | - Jeong-Won Lee
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710, Korea
| | - Byoung-Gie Kim
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710, Korea
| |
Collapse
|
22
|
Kim YS. Clinical application of high-intensity focused ultrasound ablation for uterine fibroids. Biomed Eng Lett 2017; 7:99-105. [PMID: 30603156 DOI: 10.1007/s13534-017-0012-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Revised: 10/26/2016] [Accepted: 11/06/2016] [Indexed: 12/17/2022] Open
Abstract
HIFU (high-intensity focused ultrasound) ablation is an emerging therapeutic modality that induces thermal coagulative necrosis of biological tissues by focusing high-energy ultrasound waves onto one small spot. This technique is at various stages of clinical applications in several organs. However, it has increasingly been used in the treatment of symptomatic uterine fibroids, a common condition affecting women. Since its first clinical use for symptomatic uterine fibroids, this technique has been recognized for safety, satisfactory therapeutic efficacy in symptom control, uterus-preserving ability, radiation-free nature, and because of the fact that it does not require hospitalization. Owing to its numerous benefits, HIFU ablation is currently one of the major therapeutic options for symptomatic uterine fibroids. In this review, several aspects ranging from the physical principle of HIFU to the long-term outcomes are summarized from the perspective of the clinical application for uterine fibroids.
Collapse
Affiliation(s)
- Young-Sun Kim
- 1Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710 Korea.,Present Address: Department of Radiology, Uterine Fibroid Integrated Management Center, MINT Intervention Hospital, 640-3, Munjeong-dong, Songpa-gu, Seoul, Korea
| |
Collapse
|
23
|
Liu J, Keserci B, Rong R, Wei J, Zhang J, Wang X. Effect of the degree of magnetic resonance-guided high-intensity focused ultrasound ablation of uterine fibroid tissue on 6-month volume reduction. Int J Gynaecol Obstet 2017; 137:92-94. [PMID: 28084010 DOI: 10.1002/ijgo.12102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Revised: 09/30/2016] [Accepted: 01/10/2017] [Indexed: 11/05/2022]
Affiliation(s)
- Jing Liu
- Department of Radiology, Peking University, First Hospital, Beijing, China
| | - Bilgin Keserci
- Philips Healthcare, MR Therapy Clinical Science, Seoul, South Korea
| | - Rong Rong
- Department of Radiology, Peking University, First Hospital, Beijing, China
| | - Juan Wei
- Philips Research China, Shanghai, China
| | | | - Xiaoying Wang
- Department of Radiology, Peking University, First Hospital, Beijing, China
| |
Collapse
|
24
|
Screening Magnetic Resonance Imaging-Based Prediction Model for Assessing Immediate Therapeutic Response to Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids. Invest Radiol 2016; 51:15-24. [PMID: 26309184 DOI: 10.1097/rli.0000000000000199] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study was to fit and validate screening magnetic resonance imaging (MRI)-based prediction models for assessing immediate therapeutic responses of uterine fibroids to MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation. MATERIALS AND METHODS Informed consent from all subjects was obtained for our institutional review board-approved study. A total of 240 symptomatic uterine fibroids (mean diameter, 6.9 cm) in 152 women (mean age, 43.3 years) treated with MR-HIFU ablation were retrospectively analyzed (160 fibroids for training, 80 fibroids for validation). Screening MRI parameters (subcutaneous fat thickness [mm], x1; relative peak enhancement [%] in semiquantitative perfusion MRI, x2; T2 signal intensity ratio of fibroid to skeletal muscle, x3) were used to fit prediction models with regard to ablation efficiency (nonperfused volume/treatment cell volume, y1) and ablation quality (grade 1-5, poor to excellent, y2), respectively, using the generalized estimating equation method. Cutoff values for achievement of treatment intent (efficiency >1.0; quality grade 4/5) were determined based on receiver operating characteristic curve analysis. Prediction performances were validated by calculating positive and negative predictive values. RESULTS Generalized estimating equation analyses yielded models of y1 = 2.2637 - 0.0415x1 - 0.0011x2 - 0.0772x3 and y2 = 6.8148 - 0.1070x1 - 0.0050x2 - 0.2163x3. Cutoff values were 1.312 for ablation efficiency (area under the curve, 0.7236; sensitivity, 0.6882; specificity, 0.6866) and 4.019 for ablation quality (0.8794; 0.7156; 0.9020). Positive and negative predictive values were 0.917 and 0.500 for ablation efficiency and 0.978 and 0.600 for ablation quality, respectively. CONCLUSIONS Screening MRI-based prediction models for assessing immediate therapeutic responses of uterine fibroids to MR-HIFU ablation were fitted and validated, which may reduce the risk of unsuccessful treatment.
Collapse
|
25
|
Kim YS, Lim HK, Rhim H. Magnetic Resonance Imaging-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids: Effect of Bowel Interposition on Procedure Feasibility and a Unique Bowel Displacement Technique. PLoS One 2016; 11:e0155670. [PMID: 27186881 PMCID: PMC4871469 DOI: 10.1371/journal.pone.0155670] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 05/02/2016] [Indexed: 11/18/2022] Open
Abstract
Purpose To evaluate the effect of bowel interposition on assessing procedure feasibility, and the usefulness and limiting conditions of bowel displacement techniques in magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids. Materials and Methods Institutional review board approved this study. A total of 375 screening MR exams and 206 MR-HIFU ablations for symptomatic uterine fibroids performed between August 2010 and March 2015 were retrospectively analyzed. The effect of bowel interposition on procedure feasibility was assessed by comparing pass rates in periods before and after adopting a unique bowel displacement technique (bladder filling, rectal filling and subsequent bladder emptying; BRB maneuver). Risk factors for BRB failure were evaluated using logistic regression analysis. Results Overall pass rates of pre- and post-BRB periods were 59.0% (98/166) and 71.7% (150/209), and in bowel-interposed cases they were 14.6% (7/48) and 76.4% (55/72), respectively. BRB maneuver was technically successful in 81.7% (49/60). Through-the-bladder sonication was effective in eight of eleven BRB failure cases, thus MR-HIFU could be initiated in 95.0% (57/60). A small uterus on treatment day was the only significant risk factor for BRB failure (B = 0.111, P = 0.017). Conclusion The BRB maneuver greatly reduces the fraction of patients deemed ineligible for MR-HIFU ablation of uterine fibroids due to interposed bowels, although care is needed when the uterus is small.
Collapse
Affiliation(s)
- Young-sun Kim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- * E-mail:
| | - Hyo Keun Lim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Health Science and Technology, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyunchul Rhim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
26
|
Kim YS, Lee JW, Choi CH, Kim BG, Bae DS, Rhim H, Lim HK. Uterine Fibroids: Correlation of T2 Signal Intensity with Semiquantitative Perfusion MR Parameters in Patients Screened for MR-guided High-Intensity Focused Ultrasound Ablation. Radiology 2016; 278:925-35. [DOI: 10.1148/radiol.2015150608] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|