Grandits T, Gillette K, Neic A, Bayer J, Vigmond E, Pock T, Plank G. An Inverse Eikonal Method for Identifying Ventricular Activation Sequences from Epicardial Activation Maps. JOURNAL OF COMPUTATIONAL PHYSICS 2020; 419:109700. [PMID: 32952215 PMCID: PMC7116090 DOI: 10.1016/j.jcp.2020.109700] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
A key mechanism controlling cardiac function is the electrical activation sequence of the heart's main pumping chambers termed the ventricles. As such, personalization of the ventricular activation sequences is of pivotal importance for the clinical utility of computational models of cardiac electrophysiology. However, a direct observation of the activation sequence throughout the ventricular volume is virtually impossible. In this study, we report on a novel method for identification of activation sequences from activation maps measured at the outer surface of the heart termed the epicardium. Conceptually, the method attempts to identify the key factors governing the ventricular activation sequence - the timing of earliest activation sites (EAS) and the velocity tensor field within the ventricular walls - from sparse and noisy activation maps sampled from the epicardial surface and fits an Eikonal model to the observations. Regularization methods are first investigated to overcome the severe ill-posedness of the inverse problem in a simplified 2D example. These methods are then employed in an anatomically accurate biventricular model with two realistic activation models of varying complexity - a simplified trifascicular model (3F) and a topologically realistic model of the His-Purkinje system (HPS). Using epicardial activation maps at full resolution, we first demonstrate that reconstructing the volumetric activation sequence is, in principle, feasible under the assumption of known location of EAS and later evaluate robustness of the method against noise and reduced spatial resolution of observations. Our results suggest that the FIMIN algorithm is able to robustly recover the full 3D activation sequence using epicardial activation maps at a spatial resolution achievable with current mapping systems and in the presence of noise. Comparing the accuracy achieved in the reconstructed activation maps with clinical data uncertainties suggests that the FIMIN method may be suitable for the patient- specific parameterization of activation models.
Collapse
Affiliation(s)
- Thomas Grandits
- Institute of Computer Graphics and Vision, Graz University of Technology
- BioTechMed-Graz, Austria
| | - Karli Gillette
- Institute of Biophysics, Medical University of Graz
- BioTechMed-Graz, Austria
| | - Aurel Neic
- Institute of Biophysics, Medical University of Graz
| | - Jason Bayer
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, Pessac-Bordeaux
| | - Edward Vigmond
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, Pessac-Bordeaux
| | - Thomas Pock
- Institute of Computer Graphics and Vision, Graz University of Technology
- BioTechMed-Graz, Austria
| | - Gernot Plank
- Institute of Biophysics, Medical University of Graz
- BioTechMed-Graz, Austria
| |
Collapse
|
2
|
He K, Nie Z, Zhong G, Yang C, Sun J. Localization of origins of premature ventricular contraction in the whole ventricle based on machine learning and automatic beat recognition from 12-lead ECG. Physiol Meas 2020; 41:055007. [PMID: 32252035 DOI: 10.1088/1361-6579/ab86d7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The localization of origins of premature ventricular contraction (PVC) is the key factor for the success of ablation of ventricular arrhythmias. Existing methods rely heavily on manual extraction of PVC beats, which limits their application to the automatic PVC recognition from long-term data recorded by ECG monitors before and during operation. In addition, research identifying PVC sources in the whole ventricle have not been reported. The purpose of this study was to validate the feasibility of localization of origins of PVC in the whole ventricle and to explore an automatic algorithm for recognition of PVC beats based on long-term 12-lead ECG. APPROACH This study included 249 patients with spontaneous PVCs or pacing-induced PVCs. A novel algorithm was used to automatically extract PVC beats from a massive amount of original ECG data, which was collected by different acquisition devices. After clustering and labelling, 374 sample groups, each containing dozens to hundreds of PVC beats, formed the entire dataset of 11 categories corresponding to 11 regions of PVC origins in the whole ventricle. To choose the best classification model for the current task, four machine learning methods, support vector machine (SVM), random forest (RF), gradient-boosting decision tree (GBDT) and Gaussian naïve Bayes (GNB), were compared by randomly selecting 70% of the entire dataset (sample groups = 257) for training and the remaining 30% (sample groups = 117) for testing. The average performance of each model was estimated by the bootstrap method using 1000 resampling trials. MAIN RESULTS For PVC beat recognition, the achieved testing accuracy, sensitivity and specificity is 97.6%, 98.3% and 96.7%, respectively. For localization purpose, the achieved testing accuracy varies slightly from 70.7% to 74.1% among four classifiers, and when neighboring regions were combined, the testing rank accuracy is improved to a range of 91.5% to 93.2%. SIGNIFICANCE The proposed algorithm can automatically recognize PVC beats and map them to one of the 11 regions in the whole ventricle. Owing to the high accuracy of PVC beat recognition and the capability to target the potential PVC origins in multi regions, it is expected to be a predominant technique being used in clinical settings to automatically analyze huge ECG data before and during operation so as to replace the tedious manual identification.
Collapse
Affiliation(s)
- Kaiyue He
- Department of Electronic Engineering, Fudan University, Shanghai 200433, People's Republic of China. Authors contributed equally to this work
| | | | | | | | | |
Collapse
|
3
|
Kunisch K, Neic A, Plank G, Trautmann P. Inverse localization of earliest cardiac activation sites from activation maps based on the viscous Eikonal equation. J Math Biol 2019; 79:2033-2068. [PMID: 31473798 PMCID: PMC6858910 DOI: 10.1007/s00285-019-01419-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 05/30/2019] [Indexed: 01/25/2023]
Abstract
In this study we propose a novel method for identifying the locations of earliest activation in the human left ventricle from activation maps measured at the epicardial surface. Electrical activation is modeled based on the viscous Eikonal equation. The sites of earliest activation are identified by solving a minimization problem. Arbitrary initial locations are assumed, which are then modified based on a shape derivative based perturbation field until a minimal mismatch between the computed and the given activation maps on the epicardial surface is achieved. The proposed method is tested in two numerical benchmarks, a generic 2D unit-square benchmark, and an anatomically accurate MRI-derived 3D human left ventricle benchmark to demonstrate potential utility in a clinical context. For unperturbed input data, our localization method is able to accurately reconstruct the earliest activation sites in both benchmarks with deviations of only a fraction of the used spatial discretization size. Further, with the quality of the input data reduced by spatial undersampling and addition of noise, we demonstrate that an accurate identification of the sites of earliest activation is still feasible.
Collapse
Affiliation(s)
| | - Aurel Neic
- , Auenbruggerplatz 2, 8036, Graz, Austria
| | | | | |
Collapse
|
4
|
Yang T, Pogwizd SM, Walcott GP, Yu L, He B. Noninvasive Activation Imaging of Ventricular Arrhythmias by Spatial Gradient Sparse in Frequency Domain-Application to Mapping Reentrant Ventricular Tachycardia. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:525-539. [PMID: 30136937 PMCID: PMC6372101 DOI: 10.1109/tmi.2018.2866951] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The aim of this paper is to develop and evaluate a novel imaging method [spatial gradient sparse in frequency domain (SSF)] for the reconstruction of activation sequences of ventricular arrhythmia from noninvasive body surface potential map (BSPM) measurements. We formulated and solved the electrocardiographic inverse problem in the frequency domain, and the activation time was encoded in the phase information of the imaging solution. A cellular automaton heart model was used to generate focal ventricular tachycardia (VT). Different levels of Gaussian white noise were added to simulate noise-contaminated BSPM. The performance of SSF was compared with that of weighted minimum norm inverse solution. We also evaluated the method in a swine model with simultaneous intracardiac and body surface recordings. Four reentrant VTs were observed in pigs with myocardial infarction generated by left anterior descending artery occlusion. The imaged activation sequences of reentrant VTs were compared with those obtained from intracardiac electrograms. In focal VT simulation, SSF has increased the correlation coefficient (CC) by 5% and decreased localization errors (LEs) by 2.7 mm on average under different noise levels. In the animal validation with reentrant VT, SSF has achieved an average CC of 88% and an average LE of 6.3 mm in localizing the earliest and latest activation site in the reentry circuit. Our promising results suggest that the SSF provides noninvasive imaging capability of detecting and mapping macro-reentrant circuits in 3-D ventricular space. The SSF may become a useful imaging tool of identifying and localizing the potential targets for ablation of focal and reentrant VT.
Collapse
Affiliation(s)
- Ting Yang
- Biomedical Engineering Department, University of Minnesota, Minneapolis, MN 55455, USA
| | - Steven M. Pogwizd
- Division of Cardiovascular Disease, School of Medicine, the University of Alabama at Birmingham, Birmingham, AL 0019, USA
| | - Gregory P. Walcott
- Division of Cardiovascular Disease, School of Medicine, the University of Alabama at Birmingham, Birmingham, AL 0019, USA
| | - Long Yu
- Biomedical Engineering Department, University of Minnesota, Minneapolis, MN 55455, USA
| | | |
Collapse
|
5
|
Zhou S, Sapp JL, Dawoud F, Horacek BM. Localization of Activation Origin on Patient-Specific Epicardial Surface by Empirical Bayesian Method. IEEE Trans Biomed Eng 2018; 66:1380-1389. [PMID: 30281434 DOI: 10.1109/tbme.2018.2872983] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Ablation treatment of ventricular arrhythmias can be facilitated by pre-procedure planning aided by electrocardiographic inverse solution, which can help to localize the origin of arrhythmia. Our aim was to improve localization accuracy of the inverse solution by using a novel Bayesian approach. METHODS The inverse problem of electrocardiography was solved by reconstructing epicardial potentials from 120 body-surface electrocardiograms and from patient-specific geometry of the heart and torso for four patients suffering from scar-related ventricular tachycardia who underwent epicardial catheter mapping, which included pace-mapping. Simulations using dipole sources in patient-specific geometry were also performed. The proposed method, using dynamic spatio-temporal a priori constraints of the solution, was compared with classical Tikhonov methods based on fixed constraints. RESULTS The mean localization error of the proposed method for all available pacing sites (n=78) was significantly smaller than that achieved by Tikhonov methods; specifically, the localization accuracy for pacing in the normal tissue (n=17) was [Formula: see text] mm (mean ± SD) versus [Formula: see text] mm reported in the previous study using the same clinical data and Tikhonov regularization. Simulation experiments further supported these clinical findings. CONCLUSION The promising results of in vivo and in silico experiments presented in this study provide a strong incentive to pursuing further investigation of data-driven Bayesian methods in solving the electrocardiographic inverse problem. SIGNIFICANCE The proposed approach to localizing origin of ventricular activation sequence may have important applications in pre-procedure assessment of arrhythmias and in guiding their ablation treatment.
Collapse
|
6
|
Yang T, Yu L, Jin Q, Wu L, He B. Localization of Origins of Premature Ventricular Contraction by Means of Convolutional Neural Network From 12-Lead ECG. IEEE Trans Biomed Eng 2018; 65:1662-1671. [PMID: 28952932 PMCID: PMC6089373 DOI: 10.1109/tbme.2017.2756869] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE This paper proposes a novel method to localize origins of premature ventricular contractions (PVCs) from 12-lead electrocardiography (ECG) using convolutional neural network (CNN) and a realistic computer heart model. METHODS The proposed method consists of two CNNs (Segment CNN and Epi-Endo CNN) to classify among ventricular sources from 25 segments and from epicardium (Epi) or endocardium (Endo). The inputs are the full time courses and the first half of QRS complexes of 12-lead ECG, respectively. After registering the ventricle computer model with an individual patient's heart, the training datasets were generated by multiplying ventricular current dipoles derived from single pacing at various locations with patient-specific lead field. The origins of PVC are localized by calculating the weighted center of gravity of classification returned by the CNNs. A number of computer simulations were conducted to evaluate the proposed method under a variety of noise levels and heart registration errors. Furthermore, the proposed method was evaluated on 90 PVC beats from nine human patients with PVCs and compared against ablation outcome in the same patients. RESULTS The computer simulation evaluation returned relatively high accuracies for Segment CNN (∼78%) and Epi-Endo CNN (∼90%). Clinical testing in nine PVC patients resulted an averaged localization error of 11 mm. CONCLUSION Our simulation and clinical evaluation results demonstrate the capability and merits of the proposed CNN-based method for localization of PVC. SIGNIFICANCE This paper suggests a new approach for cardiac source localization of origin of arrhythmias using only the 12-lead ECG by means of CNN, and may have important applications for future real-time monitoring and localizing origins of cardiac arrhythmias guiding ablation treatment.
Collapse
|
7
|
Yang T, Yu L, Jin Q, Wu L, He B. Activation recovery interval imaging of premature ventricular contraction. PLoS One 2018; 13:e0196916. [PMID: 29906289 PMCID: PMC6003683 DOI: 10.1371/journal.pone.0196916] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2018] [Accepted: 04/23/2018] [Indexed: 01/23/2023] Open
Abstract
Dispersion of ventricular repolarization due to abnormal activation contributes to the susceptibility to cardiac arrhythmias. However, the global pattern of repolarization is difficult to assess clinically. Activation recovery interval (ARI) has been used to understand the properties of ventricular repolarization. In this study, we developed an ARI imaging technique to noninvasively reconstruct three-dimensional (3D) ARI maps in 10 premature ventricular contraction (PVC) patients and evaluated the results with the endocardial ARI maps recorded by a clinical navigation system (CARTO). From the analysis results of a total of 100 PVC beats in 10 patients, the average correlation coefficient is 0.86±0.05 and the average relative error is 0.06±0.03. The average localization error is 4.5±2.3 mm between the longest ARI sites in 3D ARI maps and those in CARTO endocardial ARI maps. The present results suggest that ARI imaging could serve as an alternative of evaluating global pattern of ventricular repolarization noninvasively and could assist in the future investigation of the relationship between global repolarization dispersion and the susceptibility to cardiac arrhythmias.
Collapse
Affiliation(s)
- Ting Yang
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States of America
| | - Long Yu
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States of America
| | - Qi Jin
- Department of Cardiology, Shanghai Ruijin Hospital, Shanghai, China
| | - Liqun Wu
- Department of Cardiology, Shanghai Ruijin Hospital, Shanghai, China
| | - Bin He
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States of America
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, United States of America
| |
Collapse
|
8
|
Giffard-Roisin S, Delingette H, Jackson T, Webb J, Fovargue L, Lee J, Rinaldi CA, Razavi R, Ayache N, Sermesant M. Transfer Learning From Simulations on a Reference Anatomy for ECGI in Personalized Cardiac Resynchronization Therapy. IEEE Trans Biomed Eng 2018; 66:343-353. [PMID: 29993409 DOI: 10.1109/tbme.2018.2839713] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
GOAL Noninvasive cardiac electrophysiology (EP) model personalisation has raised interest for instance in the scope of predicting EP cardiac resynchronization therapy (CRT) response. However, the restricted clinical applicability of current methods is due in particular to the limitation to simple situations and the important computational cost. METHODS We propose in this manuscript an approach to tackle these two issues. First, we analyze more complex propagation patterns (multiple onsets and scar tissue) using relevance vector regression and shape dimensionality reduction on a large simulated database. Second, this learning is performed offline on a reference anatomy and transferred onto patient-specific anatomies in order to achieve fast personalized predictions online. RESULTS We evaluated our method on a dataset composed of 20 dyssynchrony patients with a total of 120 different cardiac cycles. The comparison with a commercially available electrocardiographic imaging (ECGI) method shows a good identification of the cardiac activation pattern. From the cardiac parameters estimated in sinus rhythm, we predicted five different paced patterns for each patient. The comparison with the body surface potential mappings (BSPM) measured during pacing and the ECGI method indicates a good predictive power. CONCLUSION We showed that learning offline from a large simulated database on a reference anatomy was able to capture the main cardiac EP characteristics from noninvasive measurements for fast patient-specific predictions. SIGNIFICANCE The fast CRT pacing predictions are a step forward to a noninvasive CRT patient selection and therapy optimisation, to help clinicians in these difficult tasks.
Collapse
|
9
|
Giffard-Roisin S, Jackson T, Fovargue L, Lee J, Delingette H, Razavi R, Ayache N, Sermesant M. Noninvasive Personalization of a Cardiac Electrophysiology Model From Body Surface Potential Mapping. IEEE Trans Biomed Eng 2016; 64:2206-2218. [PMID: 28113292 DOI: 10.1109/tbme.2016.2629849] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
GOAL We use noninvasive data (body surface potential mapping, BSPM) to personalize the main parameters of a cardiac electrophysiological (EP) model for predicting the response to different pacing conditions. METHODS First, an efficient forward model is proposed, coupling the Mitchell-Schaeffer transmembrane potential model with a current dipole formulation. Then, we estimate the main parameters of the cardiac model: activation onset location and tissue conductivity. A large patient-specific database of simulated BSPM is generated, from which specific features are extracted to train a machine learning algorithm. The activation onset location is computed from a Kernel Ridge Regression and a second regression calibrates the global ventricular conductivity. RESULTS The evaluation of the results is done both on a benchmark dataset of a patient with premature ventricular contraction (PVC) and on five nonischaemic implanted cardiac resynchonization therapy (CRT) patients with a total of 21 different pacing conditions. Good personalization results were found in terms of the activation onset location for the PVC (mean distance error, MDE = 20.3 mm), for the pacing sites (MDE = 21.7 mm) and for the CRT patients (MDE = 24.6 mm). We tested the predictive power of the personalized model for biventricular pacing and showed that we could predict the new electrical activity patterns with a good accuracy in terms of BSPM signals. CONCLUSION We have personalized the cardiac EP model and predicted new patient-specific pacing conditions. SIGNIFICANCE This is an encouraging first step towards a noninvasive preoperative prediction of the response to different pacing conditions to assist clinicians for CRT patient selection and therapy planning.
Collapse
|
10
|
Zhou Z, Jin Q, Yu L, Wu L, He B. Noninvasive Imaging of Human Atrial Activation during Atrial Flutter and Normal Rhythm from Body Surface Potential Maps. PLoS One 2016; 11:e0163445. [PMID: 27706179 PMCID: PMC5051739 DOI: 10.1371/journal.pone.0163445] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Accepted: 09/08/2016] [Indexed: 11/19/2022] Open
Abstract
Background Knowledge of atrial electrophysiological properties is crucial for clinical intervention of atrial arrhythmias and the investigation of the underlying mechanism. This study aims to evaluate the feasibility of a novel noninvasive cardiac electrical imaging technique in imaging bi-atrial activation sequences from body surface potential maps (BSPMs). Methods The study includes 7 subjects, with 3 atrial flutter patients, and 4 healthy subjects with normal atrial activations. The subject-specific heart-torso geometries were obtained from MRI/CT images. The equivalent current densities were reconstructed from 208-channel BSPMs by solving the inverse problem using individual heart-torso geometry models. The activation times were estimated from the time instant corresponding to the highest peak in the time course of the equivalent current densities. To evaluate the performance, a total of 32 cycles of atrial flutter were analyzed. The imaged activation maps obtained from single beats were compared with the average maps and the activation maps measured from CARTO, by using correlation coefficient (CC) and relative error (RE). Results The cardiac electrical imaging technique is capable of imaging both focal and reentrant activations. The imaged activation maps for normal atrial activations are consistent with findings from isolated human hearts. Activation maps for isthmus-dependent counterclockwise reentry were reconstructed on three patients with typical atrial flutter. The method was capable of imaging macro counterclockwise reentrant loop in the right atrium and showed inter-atria electrical conduction through coronary sinus. The imaged activation sequences obtained from single beats showed good correlation with both the average activation maps (CC = 0.91±0.03, RE = 0.29±0.05) and the clinical endocardial findings using CARTO (CC = 0.70±0.04, RE = 0.42±0.05). Conclusions The noninvasive cardiac electrical imaging technique is able to reconstruct complex atrial reentrant activations and focal activation patterns in good consistency with clinical electrophysiological mapping. It offers the potential to assist in radio-frequency ablation of atrial arrhythmia and help defining the underlying arrhythmic mechanism.
Collapse
Affiliation(s)
- Zhaoye Zhou
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, United States of America
| | - Qi Jin
- Department of Cardiology, Ruijin Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Long Yu
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, United States of America
| | - Liqun Wu
- Department of Cardiology, Ruijin Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Bin He
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, United States of America
- Institute for Engineering in Medicine, University of Minnesota, Minneapolis, Minnesota, United States of America
- * E-mail:
| |
Collapse
|
11
|
Duchateau J, Potse M, Dubois R. Spatially Coherent Activation Maps for Electrocardiographic Imaging. IEEE Trans Biomed Eng 2016; 64:1149-1156. [PMID: 27448338 DOI: 10.1109/tbme.2016.2593003] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Cardiac mapping is an important diagnostic step in cardiac electrophysiology. One of its purposes is to generate a map of the depolarization sequence. This map is constructed in clinical routine either by directly analyzing cardiac electrograms (EGMs) recorded invasively or an estimate of these EGMs obtained by a noninvasive technique. Activation maps based on noninvasively estimated EGMs often show artefactual jumps in activation times. To overcome this problem, we present a new method to construct the activation maps from reconstructed unipolar EGMs. METHODS On top of the standard estimation of local activation time from unipolar intrinsic deflections, we propose to mutually compare the EGMs in order to estimate the delays in activation for neighboring recording locations. We then describe a workflow to construct a spatially coherent activation map from local activation times and delay estimates in order to create more accurate maps. The method is optimized using simulated data and evaluated on clinical data from 12 different activation sequences. RESULTS We found that the standard methodology created lines of artificially strong activation time gradient. The proposed workflow enhanced these maps significantly. CONCLUSION Estimating delays between neighbors is an interesting option for activation map computation in electrocardiographic imaging.
Collapse
|
12
|
Potyagaylo D, Dossel O, van Dam P. Influence of Modeling Errors on the Initial Estimate for Nonlinear Myocardial Activation Times Imaging Calculated With Fastest Route Algorithm. IEEE Trans Biomed Eng 2016; 63:2576-2584. [PMID: 27164568 DOI: 10.1109/tbme.2016.2561973] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Noninvasive reconstruction of cardiac electrical activity has a great potential to support clinical decision making, planning, and treatment. Recently, significant progress has been made in the estimation of the cardiac activation from body surface potential maps (BSPMs) using boundary element method (BEM) with the equivalent double layer (EDL) as a source model. In this formulation, noninvasive assessment of activation times results in a nonlinear optimization problem with an initial estimate calculated with the fastest route algorithm (FRA). Each FRA-simulated activation sequence is converted into the ECG. The best initialization is determined by the sequence providing the highest correlation between predicted and measured potentials. We quantitatively assess the effects of the forward modeling errors on the FRA-based initialization. We present three simulation setups to investigate the effects of volume conductor model simplifications, neglecting the cardiac anisotropy and geometrical errors on the localization of ectopic beats starting on the ventricular surface. For the analysis, 12-lead ECG and 99 electrodes BSPM system were used. The areas in the heart exposing the largest localization errors were volume conductor model and electrode configuration specific with an average error <10 mm. The results show the robustness of the FRA-based initialization with respect to the considered modeling errors.
Collapse
|