Barka ND, Smith JW, Shoyama FM, Howard BT. Intracardiac Induced Ventricular Fibrillation for the Euthanasia of Sheep. JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE : JAALAS 2023; 62:464-469. [PMID: 37673664 PMCID: PMC10597332 DOI: 10.30802/aalas-jaalas-23-000062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 07/27/2023] [Accepted: 07/28/2023] [Indexed: 09/08/2023]
Abstract
Euthanasia is the humane termination of an animal's life and an important consideration for scientists, veterinarians, regulators, and others contemplating investigations involving animals. Techniques for euthanasia must induce the most rapid, painless, and distress-free death possible. This study investigated the effectiveness of direct current induction of ventricular fibrillation for the euthanasia of sheep after a primary study in which artifacts or chemical contamination from injectable euthanasia agents were undesirable. Female crossbred adult sheep (Ovis aries; n = 12) under deep isoflurane general anesthesia were instrumented with electrophysiology catheters to induce ventricular fibrillation for euthanasia. Data regarding invasive arterial blood pressure, expired airway gases, limb lead electrocardiograms, and pulse oximetry were collected and assessed just prior to, immediately after, and at 5, 10, 15, and 20min after energy delivery. In all animals, a single 10-s application of 9V of direct current to the right ventricular endocardium via the electrophysiology catheter induced persistent ventricular fibrillation. Arterial blood pressure (mean ± 1 SD) immediately after fibrillation induction was 22.9±4.5mmHg, with negligible difference between systolic and diastolic pressures. The lack of differential pressure continued through the end of the monitoring period. Arterial blood pressure reached an initial nadir at 1??0.5min after fibrillation induction, peaked (40.8±11.1mmHg) due to a vasoconstrictive reflex at 3min after induction, and returned to a static uniform pressure (20.4±17.8mmHg) with mildly increased variability due to reflexive diaphragmatic contractions at 10min after induction. The use of 9V direct current for the induction of ventricular fibrillation via an electrophysiology catheter is a reliable method of euthanasia in sheep.
Collapse
|
2
|
Anderson RD, Massé S, Asta J, Lai PFH, Chakraborty P, Azam MA, Downar E, Nanthakumar K. Role of Purkinje-Muscle Junction in Early Ventricular Fibrillation in a Porcine Model: Beyond the Trigger Concept. Pacing Clin Electrophysiol 2022; 45:742-751. [PMID: 35067947 DOI: 10.1111/pace.14453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 01/01/2022] [Accepted: 01/14/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND The role of the Purkinje network in triggering ventricular fibrillation (VF) has been studied, however, its involvement after onset and in early maintenance of VF is controversial. AIM We studied the role of the Purkinje-muscle junctions (PMJ) on epicardial-endocardial activation gradients during early VF. METHODS In a healthy, porcine, beating-heart Langendorff model [control, n = 5; ablation, n = 5], simultaneous epicardial-endocardial dominant frequent mapping was used (224 unipolar electrograms) to calculate activation rate gradients during the onset and early phase of VF. Selective Purkinje ablation was performed using Lugol's solution, followed by VF re-induction and mapping and finally, histological evaluation. RESULTS Epicardial activation rates were faster than endocardial rates for both onset and early VF. After PMJ ablation, activation rates decreased epicardially and endocardially for both onset and early VF [Epi: 9.7±0.2 to 8.3±0.2 Hz (P<0.0001) and 10.9±0.4 to 8.8±0.3 Hz (P<0.0001), respectively; Endo: 8.2 ± 0.3 Hz to 7.4 ± 0.2 Hz (P<0.0001) and 7.0 ± 0.4 Hz to 6.6 ± 0.3 Hz (P = 0.0002), respectively]. In controls, epicardial-endocardial activation rate gradients during onset and early VF were 1.7±0.3 Hz and 4.5±0.4 Hz (P<0.001), respectively. After endocardial ablation of PMJs, these gradients were reduced to 0.9±0.3 Hz (onset VF, P<0.001) and to 2.2±0.3 Hz (early VF, P<0.001). Endocardial-epicardial Purkinje fibre arborization and selective Purkinje fibre extinction after only endocardial ablation (not with epicardial ablation) was confirmed on histological analysis. CONCLUSIONS Beyond the trigger paradigm, PMJs determine activation rate gradients during onset and during early maintenance of VF. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Robert D Anderson
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Canada
| | - Stéphane Massé
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Canada
| | - John Asta
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Canada
| | - Patrick F H Lai
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Canada
| | - Praloy Chakraborty
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Canada
| | - Mohammed Ali Azam
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Canada
| | - Eugene Downar
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Canada
| | - Kumaraswamy Nanthakumar
- The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, Toronto, Canada
| |
Collapse
|
3
|
Herndon C, Astley HC, Owerkowicz T, Fenton FH. Defibrillate You Later, Alligator: Q10 Scaling and Refractoriness Keeps Alligators from Fibrillation. Integr Org Biol 2021; 3:obaa047. [PMID: 33977229 PMCID: PMC8101277 DOI: 10.1093/iob/obaa047] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Effective cardiac contraction during each heartbeat relies on the coordination of an electrical wave of excitation propagating across the heart. Dynamically induced heterogeneous wave propagation may fracture and initiate reentry-based cardiac arrhythmias, during which fast-rotating electrical waves lead to repeated self-excitation that compromises cardiac function and potentially results in sudden cardiac death. Species which function effectively over a large range of heart temperatures must balance the many interacting, temperature-sensitive biochemical processes to maintain normal wave propagation at all temperatures. To investigate how these species avoid dangerous states across temperatures, we optically mapped the electrical activity across the surfaces of alligator (Alligator mississippiensis) hearts at 23°C and 38°C over a range of physiological heart rates and compare them with that of rabbits (Oryctolagus cuniculus). We find that unlike rabbits, alligators show minimal changes in wave parameters (action potential duration and conduction velocity) which complement each other to retain similar electrophysiological wavelengths across temperatures and pacing frequencies. The cardiac electrophysiology of rabbits accommodates the high heart rates necessary to sustain an active and endothermic metabolism at the cost of increased risk of cardiac arrhythmia and critical vulnerability to temperature changes, whereas that of alligators allows for effective function over a range of heart temperatures without risk of cardiac electrical arrhythmias such as fibrillation, but is restricted to low heart rates. Synopsis La contracción cardíaca efectiva durante cada latido del corazón depende de la coordinación de una onda eléctrica de excitación que se propaga a través del corazón. Heterogéidades inducidas dinámicamente por ondas de propagación pueden resultar en fracturas de las ondas e iniciar arritmias cardíacas basadas en ondas de reingreso, durante las cuales ondas espirales eléctricas de rotación rápida producen una autoexcitación repetida que afecta la función cardíaca y pude resultar en muerte súbita cardíaca. Las especies que funcionan eficazmente en una amplia gama de temperaturas cardíacas deben equilibrar los varios procesos bioquímicos que interactúan, sensibles a la temperatura para mantener la propagación normal de ondas a todas las temperaturas. Para investigar cómo estas especies evitan los estados peligrosos a través de las temperaturas, mapeamos ópticamente la actividad eléctrica a través de las superficies de los corazones de caimanes (Alligator mississippiensis) a 23°C and 38°C sobre un rango de frecuencias fisiológicas del corazón y comparamos con el de los conejos (Oryctolagus cuniculus). Encontramos que a diferencia de los conejos, los caimanes muestran cambios mínimos en los parámetros de onda (duración potencial de acción y velocidad de conducción) que se complementan entre sí para retener longitudes de onda electrofisiológicas similares a través de los rangos de temperaturas y frecuencias de ritmo. La electrofisiología cardíaca de los conejos acomoda las altas frecuencias cardíacas necesarias para mantener un metabolismo activo y endotérmico a costa de un mayor riesgo de arritmia cardíaca y vulnerabilidad crítica a los cambios de temperatura, mientras que la de los caimanes permite un funcionamiento eficaz en una serie de temperaturas cardíacas sin riesgo de arritmias eléctricas cardíacas como la fibrilación, pero está restringida a bajas frecuencias cardíacas.
Collapse
Affiliation(s)
- Conner Herndon
- School of Physics, Georgia Institute of Technology, Atlanta, GA, USA
| | - Henry C Astley
- Department of Biology, Biomimicry Research & Innovation Center, University of Akron, Akron, OH, USA
| | - Tomasz Owerkowicz
- Department of Biology, California State University, San Bernardino, CA, USA
| | - Flavio H Fenton
- School of Physics, Georgia Institute of Technology, Atlanta, GA, USA
| |
Collapse
|
4
|
Neuber JU, Varghese F, Pakhomov AG, Zemlin CW. Using Nanosecond Shocks for Cardiac Defibrillation. Bioelectricity 2019; 1:240-246. [PMID: 32685917 DOI: 10.1089/bioe.2019.0030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
The purpose of this review article is to summarize our current understanding of the efficacy and safety of cardiac defibrillation with nanosecond shocks. Experiments in isolated hearts, using optical mapping of the electrical activity, have demonstrated that nanosecond shocks can defibrillate with lower energies than conventional millisecond shocks. Single defibrillation strength nanosecond shocks do not cause obvious damage, but repeated stimulation leads to deterioration of the hearts. In isolated myocytes, nanosecond pulses can also stimulate at lower energies than at longer pulses and cause less electroporation (propidium uptake). The mechanism is likely electroporation of the plasma membrane. Repeated stimulation leads to distorted calcium gradients.
Collapse
Affiliation(s)
- Johanna U Neuber
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, Virginia.,Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, Virginia
| | - Frency Varghese
- Department of Medicine, University of Massachusetts Medical School, Worcester, Massachusetts
| | - Andrei G Pakhomov
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, Virginia
| | - Christian W Zemlin
- Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, Virginia.,Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, Virginia
| |
Collapse
|
5
|
Kroll MW, Panescu D, Hirtler R, Koch M, Andrews CJ. Dosimetry for Ventricular Fibrillation Risk with Short Electrical Pulses: History and Future. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:1788-1794. [PMID: 31946244 DOI: 10.1109/embc.2019.8857787] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
UNLABELLED Electrical safety limits for unidirectional pulses with short durations are increasingly important due to the proliferation of electric-car and factory energy storage systems with potentially dangerous voltages. Electrocution by a short-duration direct-current pulse is not understood as well as that by alternating current and the data are limited. The primary international guidance comes from IEC 60479-2 section 11. METHODS We have analyzed the dosimetry for short pulse safety limits based on a fuller understanding of the scientific principles involved and human data. Implantable defibrillators have been tested by externally delivering short-duration pulses giving us human data which we analyze for this paper. RESULTS The present IEC current limit (60479-2:11) for short pulse durations is based on an exponent of -0.68 in the equation I = d-0.68, (d being pulse width), while the correct exponent should be -1.0 given the constant charge for the VF threshold of short pulses. We also propose a baseline charge value based on the human data. CONCLUSIONS Charge-based VF thresholds give the correct dosimetry for short-duration pulses. Results from this paper should be considered in support of revising the IEC 60479-2 standard section 11.
Collapse
|
6
|
Connolly A, Kelly A, Campos FO, Myles R, Smith G, Bishop MJ. Ventricular Endocardial Tissue Geometry Affects Stimulus Threshold and Effective Refractory Period. Biophys J 2018; 115:2486-2498. [PMID: 30503533 PMCID: PMC6301915 DOI: 10.1016/j.bpj.2018.11.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 10/15/2018] [Accepted: 11/05/2018] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND Understanding the biophysical processes by which electrical stimuli applied to cardiac tissue may result in local activation is important in both the experimental and clinical electrophysiology laboratory environments, as well as for gaining a more in-depth knowledge of the mechanisms of focal-trigger-induced arrhythmias. Previous computational models have predicted that local myocardial tissue architecture alone may significantly modulate tissue excitability, affecting both the local stimulus current required to excite the tissue and the local effective refractory period (ERP). In this work, we present experimental validation of this structural modulation of local tissue excitability on the endocardial tissue surface, use computational models to provide mechanistic understanding of this phenomena in relation to localized changes in electrotonic loading, and demonstrate its implications for the capture of afterdepolarizations. METHODS AND RESULTS Experiments on rabbit ventricular wedge preparations showed that endocardial ridges (surfaces of negative mean curvature) had a stimulus capture threshold that was 0.21 ± 0.03 V less than endocardial grooves (surfaces of positive mean curvature) for pairwise comparison (24% reduction, corresponding to 56.2 ± 6.4% of the energy). When stimulated at the minimal stimulus strength for capture, ridge locations showed a shorter ERP than grooves (n = 6, mean pairwise difference 7.4 ± 4.2 ms). When each site was stimulated with identical-strength stimuli, the difference in ERP was further increased (mean pairwise difference 15.8 ± 5.3 ms). Computational bidomain models of highly idealized cylindrical endocardial structures qualitatively agreed with these findings, showing that such changes in excitability are driven by structural modulation in electrotonic loading, quantifying this relationship as a function of surface curvature. Simulations further showed that capture of delayed afterdepolarizations was more likely in trabecular ridges than grooves, driven by this difference in loading. CONCLUSIONS We have demonstrated experimentally and explained mechanistically in computer simulations that the ability to capture tissue on the endocardial surface depends upon the local tissue architecture. These findings have important implications for deepening our understanding of excitability differences related to anatomical structure during stimulus application that may have important applications in the translation of novel experimental optogenetics pacing strategies. The uncovered preferential vulnerability to capture of afterdepolarizations of endocardial ridges, compared to grooves, provides important insight for understanding the mechanisms of focal-trigger-induced arrhythmias.
Collapse
Affiliation(s)
- Adam Connolly
- Department of Bioengineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Allen Kelly
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, United Kingdom
| | - Fernando O Campos
- Department of Bioengineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Rachel Myles
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, United Kingdom
| | - Godfrey Smith
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, United Kingdom
| | - Martin J Bishop
- Department of Bioengineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
| |
Collapse
|
7
|
Kalla M, Chotalia M, Coughlan C, Hao G, Crabtree MJ, Tomek J, Bub G, Paterson DJ, Herring N. Protection against ventricular fibrillation via cholinergic receptor stimulation and the generation of nitric oxide. J Physiol 2016; 594:3981-92. [PMID: 26752781 PMCID: PMC4794549 DOI: 10.1113/jp271588] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Accepted: 01/06/2016] [Indexed: 12/12/2022] Open
Abstract
KEY POINTS Animal studies suggest an anti-fibrillatory action of the vagus nerve on the ventricle, although the exact mechanism is controversial. Using a Langendorff perfused rat heart, we show that the acetylcholine analogue carbamylcholine raises ventricular fibrillation threshold (VFT) and flattens the electrical restitution curve. The anti-fibrillatory action of carbamylcholine was prevented by the nicotinic receptor antagonist mecamylamine, inhibitors of neuronal nitric oxide synthase (nNOS) and soluble guanylyl cyclase (sGC), and can be mimicked by the nitric oxide (NO) donor sodium nitroprusside. Carbamylcholine increased NO metabolite content in the coronary effluent and this was prevented by mecamylamine. The anti-fibrillatory action of both carbamylcholine and sodium nitroprusside was ultimately dependent on muscarinic receptor stimulation as all effects were blocked by atropine. These data demonstrate a protective effect of carbamylcholine on VFT that depends upon both muscarinic and nicotinic receptor stimulation, where the generation of NO is likely to be via a neuronal nNOS-sGC dependent pathway. ABSTRACT Implantable cardiac vagal nerve stimulators are a promising treatment for ventricular arrhythmia in patients with heart failure. Animal studies suggest the anti-fibrillatory effect may be nitric oxide (NO) dependent, although the exact site of action is controversial. We investigated whether a stable analogue of acetylcholine could raise ventricular fibrillation threshold (VFT), and whether this was dependent on NO generation and/or muscarinic/nicotinic receptor stimulation. VFT was determined in Langendorff perfused rat hearts by burst pacing until sustained VF was induced. Carbamylcholine (CCh, 200 nmol l(-1) , n = 9) significantly (P < 0.05) reduced heart rate from 292 ± 8 to 224 ± 6 b.p.m. Independent of this heart rate change, CCh caused a significant increase in VFT (control 1.5 ± 0.3 mA, CCh 2.4 ± 0.4 mA, wash 1.1 ± 0.2 mA) and flattened the restitution curve (n = 6) derived from optically mapped action potentials. The effect of CCh on VFT was abolished by a muscarinic (atropine, 0.1 μmol l(-1) , n = 6) or a nicotinic receptor antagonist (mecamylamine, 10 μmol l(-1) , n = 6). CCh significantly increased NOx content in coronary effluent (n = 8), but not in the presence of mecamylamine (n = 8). The neuronal nitric oxide synthase inhibitor AAAN (N-(4S)-4-amino-5-[aminoethyl]aminopentyl-N'-nitroguanidine; 10 μmol l(-1) , n = 6) or soluble guanylate cyclase (sGC) inhibitor ODQ (1H-[1,2,4]oxadiazolo[4,3-a]quinoxalin-1-one; 10 μmol l(-1) , n = 6) prevented the rise in VFT with CCh. The NO donor sodium nitrprusside (10 μmol l(-1) , n = 8) mimicked the action of CCh on VFT, an effect that was also blocked by atropine (n = 10). These data demonstrate a protective effect of CCh on VFT that depends upon both muscarinic and nicotinic receptor stimulation, where the generation of NO is likely to be via a neuronal nNOS/sGC-dependent pathway.
Collapse
Affiliation(s)
- Manish Kalla
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| | - Minesh Chotalia
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| | - Charles Coughlan
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| | - Guoliang Hao
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| | - Mark J Crabtree
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| | - Jakub Tomek
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| | - Gil Bub
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| | - David J Paterson
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| | - Neil Herring
- Burdon Sanderson Cardiac Science Centre, Department of Physiology, Anatomy and Genetics, Sherrington Building, University of Oxford, Oxford, UK
| |
Collapse
|
8
|
Images as drivers of progress in cardiac computational modelling. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2014; 115:198-212. [PMID: 25117497 PMCID: PMC4210662 DOI: 10.1016/j.pbiomolbio.2014.08.005] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Accepted: 08/02/2014] [Indexed: 11/28/2022]
Abstract
Computational models have become a fundamental tool in cardiac research. Models are evolving to cover multiple scales and physical mechanisms. They are moving towards mechanistic descriptions of personalised structure and function, including effects of natural variability. These developments are underpinned to a large extent by advances in imaging technologies. This article reviews how novel imaging technologies, or the innovative use and extension of established ones, integrate with computational models and drive novel insights into cardiac biophysics. In terms of structural characterization, we discuss how imaging is allowing a wide range of scales to be considered, from cellular levels to whole organs. We analyse how the evolution from structural to functional imaging is opening new avenues for computational models, and in this respect we review methods for measurement of electrical activity, mechanics and flow. Finally, we consider ways in which combined imaging and modelling research is likely to continue advancing cardiac research, and identify some of the main challenges that remain to be solved.
Collapse
|