1
|
Hartmann JP, Lassen ML, Mohammad M, Iepsen UW, Mortensen J, Hasbak P, Berg RMG. Pulmonary blood volume measured by 82Rb-PET in patients with chronic obstructive pulmonary disease: a retrospective cohort study. J Appl Physiol (1985) 2024; 136:1276-1283. [PMID: 38602000 DOI: 10.1152/japplphysiol.00058.2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 04/03/2024] [Accepted: 04/03/2024] [Indexed: 04/12/2024] Open
Abstract
In patients with chronic obstructive pulmonary disease (COPD), pulmonary vascular dysfunction and destruction are observable before the onset of detectable emphysema, but it is unknown whether this is associated with central hypovolemia. We investigated if patients with COPD have reduced pulmonary blood volume (PBV) evaluated by 82Rb-positron emission tomography (PET) at rest and during adenosine-induced hyperemia. This single-center retrospective cohort study assessed 6,301 82Rb-PET myocardial perfusion imaging (MPI) examinations performed over a 6-yr period. We compared 77 patients with COPD with 44 healthy kidney donors (controls). Cardiac output ([Formula: see text]) and mean 82Rb bolus transit time (MBTT) were used to calculate PBV. [Formula: see text] was similar at rest (COPD: 3,649 ± 120 mL vs. control: 3,891 ± 160 mL, P = 0.368) but lower in patients with COPD compared with controls during adenosine infusion (COPD: 5,432 ± 124 mL vs. control: 6,185 ± 161 mL, P < 0.050). MBTT was shorter in patients with COPD compared with controls at rest (COPD: 8.7 ± 0.28 s vs. control: 11.4 ± 0.37 s, P < 0.001) and during adenosine infusion (COPD: 9.2 ± 0.28 s vs. control: 10.2 ± 0.37 s, P < 0.014). PBV was lower in patients with COPD, even after adjustment for body surface area, sex, and age at rest [COPD: 530 (29) mL vs. 708 (38) mL, P < 0.001] and during adenosine infusion [COPD: 826 (29) mL vs. 1,044 (38) mL, P < 0.001]. In conclusion, patients with COPD show evidence of central hypovolemia, but it remains to be determined whether this has any diagnostic or prognostic impact.NEW & NOTEWORTHY The present study demonstrated that patients with chronic obstructive pulmonary disease (COPD) exhibit central hypovolemia compared with healthy controls. Pulmonary blood volume may thus be a relevant physiological and/or clinical outcome measure in future COPD studies.
Collapse
Affiliation(s)
- Jacob Peter Hartmann
- Centre for Physical Activity Research, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Martin Lyngby Lassen
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Milan Mohammad
- Centre for Physical Activity Research, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
| | - Ulrik Winning Iepsen
- Centre for Physical Activity Research, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Anaesthesiology and Intensive Care, Copenhagen University Hospital-Hvidovre, Copenhagen, Denmark
| | - Jann Mortensen
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
| | - Philip Hasbak
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
| | - Ronan M G Berg
- Centre for Physical Activity Research, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Neurovascular Research Laboratory, Faculty of Life Sciences and Education, University of South Wales, Pontypridd, United Kingdom
| |
Collapse
|
2
|
Lassen ML, Byrne C, Hartmann JP, Kjaer A, Berg RMG, Hasbak P. Pulmonary blood volume assessment from a standard cardiac rubidium-82 imaging protocol: impact of adenosine-induced hyperemia. J Nucl Cardiol 2023; 30:2504-2513. [PMID: 37349559 PMCID: PMC10682170 DOI: 10.1007/s12350-023-03308-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 05/08/2023] [Indexed: 06/24/2023]
Abstract
BACKGROUND This study aimed to assess the feasibility of estimating the pulmonary blood volume noninvasively using standard Rubidium-82 myocardial perfusion imaging (MPI) and characterize the changes during adenosine-induced hyperemia. METHODS This study comprised 33 healthy volunteers (15 female, median age = 23 years), of which 25 underwent serial rest/adenosine stress Rubidium-82 MPI sessions. Mean bolus transit times (MBTT) were obtained by calculating the time delay from the Rubidium-82 bolus arrival in the pulmonary trunk to the arrival in the left myocardial atrium. Using the MBTT, in combination with stroke volume (SV) and heart rate (HR), we estimated pulmonary blood volume (PBV = (SV × HR) × MBTT). We report the empirically measured MBTT, HR, SV, and PBV, all stratified by sex [male (M) vs female (F)] as mean (SD). In addition, we report grouped repeatability measures using the within-subject repeatability coefficient. RESULTS Mean bolus transit times was shortened during adenosine stressing with sex-specific differences [(seconds); Rest: Female (F) = 12.4 (1.5), Male (M) = 14.8 (2.8); stress: F = 8.8 (1.7), M = 11.2 (3.0), all P ≤ 0.01]. HR and SV increased during stress MPI, with a concomitant increase in the PBV [mL]; Rest: F = 544 (98), M = 926 (105); Stress: F = 914 (182), M = 1458 (338), all P < 0.001. The following test-retest repeatability measures were observed for MBTT (Rest = 17.2%, Stress = 17.9%), HR (Rest = 9.1%, Stress = 7.5%), SV (Rest = 8.9%, Stress = 5.6%), and for PBV measures (Rest = 20.7%, Stress = 19.5%) CONCLUSION: Pulmonary blood volume can be extracted by cardiac rubidium-82 MPI with excellent test-retest reliability, both at rest and during adenosine-induced hyperemia.
Collapse
Affiliation(s)
- Martin Lyngby Lassen
- Department of Clinical Physiology, Nuclear Medicine and PET, University Hospital Copenhagen-Rigshospitalet, Copenhagen, Denmark.
- Cluster for Molecular Imaging, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
| | - Christina Byrne
- Department of Clinical Physiology, Nuclear Medicine and PET, University Hospital Copenhagen-Rigshospitalet, Copenhagen, Denmark
- Cluster for Molecular Imaging, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Jacob Peter Hartmann
- Department of Clinical Physiology, Nuclear Medicine and PET, University Hospital Copenhagen-Rigshospitalet, Copenhagen, Denmark
- Renal, Cardiovascular, and Pulmonary Research, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Centre for Physical Activity Research, University Hospital Copenhagen-Rigshospitalet, Copenhagen, Denmark
| | - Andreas Kjaer
- Department of Clinical Physiology, Nuclear Medicine and PET, University Hospital Copenhagen-Rigshospitalet, Copenhagen, Denmark
- Cluster for Molecular Imaging, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Ronan M G Berg
- Department of Clinical Physiology, Nuclear Medicine and PET, University Hospital Copenhagen-Rigshospitalet, Copenhagen, Denmark
- Renal, Cardiovascular, and Pulmonary Research, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
- Centre for Physical Activity Research, University Hospital Copenhagen-Rigshospitalet, Copenhagen, Denmark
- Neurovascular Research Laboratory, Faculty of Life Sciences and Education, University of South Wales, Cardiff, UK
| | - Philip Hasbak
- Department of Clinical Physiology, Nuclear Medicine and PET, University Hospital Copenhagen-Rigshospitalet, Copenhagen, Denmark
| |
Collapse
|
3
|
Assessment of Upper Extremity Venous Compliance in Patients With Abdominal Aortic Aneurysms. Eur J Vasc Endovasc Surg 2020; 60:739-746. [PMID: 32778487 DOI: 10.1016/j.ejvs.2020.07.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 06/28/2020] [Accepted: 07/03/2020] [Indexed: 11/21/2022]
Abstract
OBJECTIVE Abdominal aortic aneurysm (AAA) is associated with morphological and functional changes in both aneurysmal and non-aneurysmal arteries. However, it remains uncertain whether similar changes also exist in the venous vasculature. The aim of this study was to evaluate global venous function in patients with AAA and controls. METHODS This experimental study comprised 31 men with AAA (mean ± standard deviation age 70.0 ± 2.8 years) and 29 male controls (aged 70.6 ± 3.4 years). Venous occlusion plethysmography (VOP) was used to evaluate arm venous compliance at venous pressures between 10 and 60 mmHg in steps of 5 mmHg. Compensatory mobilisation of venous capacitance blood (capacitance response) was measured with a volumetric technique during experimental hypovolaemia induced by lower body negative pressure (LBNP). RESULTS The VOP induced pressure-volume curve was significantly less steep in patients with AAA (interaction, p < .001), indicating lower venous compliance. Accordingly, the corresponding pressure-compliance curves displayed reduced venous compliance at lower venous pressures in patients with AAA vs. controls (interaction, p < .001; AAA vs. control, p = .018). After adjusting for arterial hypertension, diabetes mellitus, hyperlipidaemia, chronic obstructive pulmonary disease, and smoking, VOP detected differences in venous compliance remained significant at low venous pressures, that is, at 10 mmHg (p = .008), 15 mmHg (p = .013), and 20 mmHg (p = .026). Mean venous compliance was negatively correlated with aortic diameter (r = -.332, p = .010). Mobilisation of venous capacitance response during LBNP was reduced by approximately 25% in patients with AAA (p = .030), and the redistribution of venous blood during LBNP was negatively correlated with aortic diameter (r = -.417, p = .007). CONCLUSION Men with AAA demonstrated reduced venous compliance and, as a result, a lesser capacity to mobilise peripheral venous blood to the central circulation during hypovolaemic stress. These findings imply that the AAA disease may be accompanied by functional changes in the venous vascular wall.
Collapse
|
4
|
Characterization of an Artificial Liver Support System-Related Vasovagal Reaction. BIOMED RESEARCH INTERNATIONAL 2020; 2020:6313480. [PMID: 32733947 PMCID: PMC7376416 DOI: 10.1155/2020/6313480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 07/03/2020] [Indexed: 11/23/2022]
Abstract
Objective An artificial liver support system (ALSS) is an effective therapy for patients with severe liver injury. A vasovagal reaction (VVR) is a common complication in various treatment settings but has not been reported previously in ALSS. Methods This study retrospectively evaluated patients who suffered an ALSS-related VRR between January 2018 and June 2019. We collected data from VVR episodes including onset time, duration, changes in heart rate (HR) and blood pressure (BP), and drug treatment. Results Among 637 patients who underwent ALSS treatment, 18 were included in the study. The incidence of VVR was approximately 2.82%. These patients were characterized by a rapid decrease in BP or HR with associated symptoms such as chest distress, nausea, and vomiting. The majority of patients (78%) suffered a VVR during their first ALSS treatment. Sixteen patients (89%) had associated symptoms after treatment began. Sixteen patients (89%) received human albumin or Ringer's solution. Atropine was used in 11 patients (61%). The symptoms were relieved within 20 min in 15 patients and over 20 min in 3 patients. Conclusions A VVR is a rare complication in patients with severe liver injury undergoing ALSS treatment. Low BP and HR are the main characteristics of a VVR.
Collapse
|
5
|
Skoog J, Nelzén O, Zachrisson H. Venous Compliance in Great Saphenous Vein Incompetence: Pre- and Post-interventional Changes. EJVES Vasc Forum 2020. [PMCID: PMC7320196 DOI: 10.1016/j.ejvssr.2019.11.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Objective Methods Results Conclusions Venous compliance reflects the mechanical properties of the vessel wall. Calf venous compliance is reduced in patients with great saphenous vein insufficiency. Venous reflux parameters markedly improve after surgical intervention. Venous compliance is further reduced in the post-operative state.
Collapse
Affiliation(s)
- Johan Skoog
- Department of Clinical Physiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Corresponding author. Department of Clinical Physiology and Department of Health, Medicine and Caring Sciences, Linköping University, SE 581 85, Linköping, Sweden.
| | - Oskar Nelzén
- Department of Thoracic and Vascular Surgery and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Helene Zachrisson
- Department of Clinical Physiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
6
|
Lindenberger M, Fedorowski A, Melander O, Gallo W, Engvall J, Skoog J. Cardiovascular biomarkers and echocardiographic findings at rest and during graded hypovolemic stress in women with recurrent vasovagal syncope. J Cardiovasc Electrophysiol 2019; 30:2936-2943. [DOI: 10.1111/jce.14207] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 09/19/2019] [Accepted: 09/26/2019] [Indexed: 01/01/2023]
Affiliation(s)
- Marcus Lindenberger
- Department of CardiologyLinköping University HospitalLinköping Sweden
- Department of Medical and Health SciencesLinköping UniversityLinköping Sweden
| | - Arthur Fedorowski
- Department of Clinical SciencesLund UniversityMalmö Sweden
- Department of CardiologySkåne University HospitalMalmö Sweden
| | - Olle Melander
- Department of Clinical SciencesLund UniversityMalmö Sweden
| | - Widet Gallo
- Department of Clinical SciencesLund UniversityMalmö Sweden
| | - Jan Engvall
- Department of Medical and Health SciencesLinköping UniversityLinköping Sweden
| | - Johan Skoog
- Department of Medical and Health SciencesLinköping UniversityLinköping Sweden
| |
Collapse
|