1
|
Moher Alsady T, Ruschepaul J, Voskrebenzev A, Klimes F, Poehler GH, Vogel-Claussen J. Estimating ventilation correlation coefficients in the lungs using PREFUL-MRI in chronic obstructive pulmonary disease patients and healthy adults. Magn Reson Med 2024; 91:2142-2152. [PMID: 38217450 DOI: 10.1002/mrm.29982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 11/14/2023] [Accepted: 12/01/2023] [Indexed: 01/15/2024]
Abstract
PURPOSE Various parameters of regional lung ventilation can be estimated using phase-resolved functional lung (PREFUL)-MRI. The parameter "ventilation correlation coefficient (Vent-CC)" was shown advantageous because it assesses the dynamics of regional air flow. Calculating Vent-CC depends on a voxel-wise comparison to a healthy reference flow curve. This work examines the effect of placing a reference region of interest (ROI) in various lung quadrants or in different coronal slices. Furthermore, algorithms for automated ROI selection are presented and compared in terms of test-retest repeatability. METHODS Twenty-eight healthy subjects and 32 chronic obstructive pulmonary disease (COPD) patients were scanned twice using PREFUL-MRI. Retrospective analyses examined the homogeneity of air flow curves of various reference ROIs using cross-correlation. Vent-CC and ventilation defect percentage (VDP) calculated using various reference ROIs were compared using one-way analysis of variance (ANOVA). The coefficient of variation was calculated for Vent-CC and VDP when using different reference selection algorithms. RESULTS Flow-volume curves were highly correlated between ROIs placed at various lung quadrants in the same coronal slice (r > 0.97) with no differences in Vent-CC and VDP (ANOVA: p > 0.5). However, ROIs placed at different coronal slices showed lower correlation coefficients and resulted in significantly different Vent-CC and VDP values (ANOVA: p < 0.001). Vent-CC and VDP showed higher repeatability when calculated using the presented new algorithm. CONCLUSION In COPD and healthy cohorts, assessing regional ventilation dynamics using PREFUL-MRI in terms of the Vent-CC metric showed higher repeatability using a new algorithm for selecting a homogenous reference ROI from the same slice.
Collapse
Affiliation(s)
- Tawfik Moher Alsady
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Lower Saxony, Germany
- Biomedical Research in End-Stage and Obstructive Lung Disease (BREATH), German Center for Lung Research, Hannover, Lower Saxony, Germany
| | - Jakob Ruschepaul
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Lower Saxony, Germany
- Biomedical Research in End-Stage and Obstructive Lung Disease (BREATH), German Center for Lung Research, Hannover, Lower Saxony, Germany
| | - Andreas Voskrebenzev
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Lower Saxony, Germany
- Biomedical Research in End-Stage and Obstructive Lung Disease (BREATH), German Center for Lung Research, Hannover, Lower Saxony, Germany
| | - Filip Klimes
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Lower Saxony, Germany
- Biomedical Research in End-Stage and Obstructive Lung Disease (BREATH), German Center for Lung Research, Hannover, Lower Saxony, Germany
| | - Gesa Helen Poehler
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Lower Saxony, Germany
- Biomedical Research in End-Stage and Obstructive Lung Disease (BREATH), German Center for Lung Research, Hannover, Lower Saxony, Germany
| | - Jens Vogel-Claussen
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Lower Saxony, Germany
- Biomedical Research in End-Stage and Obstructive Lung Disease (BREATH), German Center for Lung Research, Hannover, Lower Saxony, Germany
| |
Collapse
|
2
|
Camporesi A, Vetrugno L, Morello R, De Rose C, Ferrario S, Buonsenso D. Prognostic Value of the Area of Lung Involved in Severe and Non-Severe Bronchiolitis: An Observational, Ultrasound-Based Study. J Clin Med 2023; 13:84. [PMID: 38202091 PMCID: PMC10780043 DOI: 10.3390/jcm13010084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/12/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024] Open
Abstract
BACKGROUND Point of care lung ultrasound (LUS) has a definite role in viral bronchiolitis when combined with clinical data. Previous data showed a bigger involvement of the superior lung zones in more severe cases. The aim of the present study is to describe whether different lung areas are implicated to different degrees in patients admitted to a Pediatric Intensive Care Unit (PICU) and needing ventilation compared to those with less severe forms. METHODS observational, prospective study. LUS scores of single lung areas and clinical data were collected for all children aged 0-12 months presenting with bronchiolitis to the participating centers and used as covariates for logistic regression having "PICU admission" as outcome. A subsequent analysis was carried out to investigate factors concurring with different lung zones' involvement. RESULTS 173 patients were enrolled. Difficulty in feeding, presence of wheezing, SpO2 were all risk factors for PICU admission. Superior lung areas' LUS scores presented higher Odds Ratios for PICU admission and need for ventilation than inferior ones. Age and prematurity concurred in determining their higher LUS scores. CONCLUSIONS Superior lobes' greater involvement could be favored by the geometrical distribution of relative bronchi, exiting with an acute angle from mainstem bronchi in small children where airway caliber is small and only small volumes of secretions can be occlusive.
Collapse
Affiliation(s)
- Anna Camporesi
- Pediatric Anesthesia and Intensive Care, Buzzi Children’s Hospital, 20154 Milano, Italy;
| | - Luigi Vetrugno
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy;
| | - Rosa Morello
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario “A. Gemelli”, 00168 Roma, Italy; (R.M.); (C.D.R.); (D.B.)
| | - Cristina De Rose
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario “A. Gemelli”, 00168 Roma, Italy; (R.M.); (C.D.R.); (D.B.)
| | - Stefania Ferrario
- Pediatric Anesthesia and Intensive Care, Buzzi Children’s Hospital, 20154 Milano, Italy;
| | - Danilo Buonsenso
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario “A. Gemelli”, 00168 Roma, Italy; (R.M.); (C.D.R.); (D.B.)
- Centro di Salute Globale, Università Cattolica del Sacro Cuore, 00168 Roma, Italy
| |
Collapse
|
3
|
Ahookhosh K, Vanoirbeek J, Vande Velde G. Lung function measurements in preclinical research: What has been done and where is it headed? Front Physiol 2023; 14:1130096. [PMID: 37035677 PMCID: PMC10073442 DOI: 10.3389/fphys.2023.1130096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Accepted: 03/10/2023] [Indexed: 04/11/2023] Open
Abstract
Due to the close interaction of lung morphology and functions, repeatable measurements of pulmonary function during longitudinal studies on lung pathophysiology and treatment efficacy have been a great area of interest for lung researchers. Spirometry, as a simple and quick procedure that depends on the maximal inspiration of the patient, is the most common lung function test in clinics that measures lung volumes against time. Similarly, in the preclinical area, plethysmography techniques offer lung functional parameters related to lung volumes. In the past few decades, many innovative techniques have been introduced for in vivo lung function measurements, while each one of these techniques has their own advantages and disadvantages. Before each experiment, depending on the sensitivity of the required pulmonary functional parameters, it should be decided whether an invasive or non-invasive approach is desired. On one hand, invasive techniques offer sensitive and specific readouts related to lung mechanics in anesthetized and tracheotomized animals at endpoints. On the other hand, non-invasive techniques allow repeatable lung function measurements in conscious, free-breathing animals with readouts related to the lung volumes. The biggest disadvantage of these standard techniques for lung function measurements is considering the lung as a single unit and providing only global readouts. However, recent advances in lung imaging modalities such as x-ray computed tomography and magnetic resonance imaging opened new doors toward obtaining both anatomical and functional information from the same scan session, without the requirement for any extra pulmonary functional measurements, in more regional and non-invasive manners. Consequently, a new field of study called pulmonary functional imaging was born which focuses on introducing new techniques for regional quantification of lung function non-invasively using imaging-based techniques. This narrative review provides first an overview of both invasive and non-invasive conventional methods for lung function measurements, mostly focused on small animals for preclinical research, including discussions about their advantages and disadvantages. Then, we focus on those newly developed, non-invasive, imaging-based techniques that can provide either global or regional lung functional readouts at multiple time-points.
Collapse
Affiliation(s)
- Kaveh Ahookhosh
- Biomedical MRI, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Jeroen Vanoirbeek
- Centre of Environment and Health, Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
| | - Greetje Vande Velde
- Biomedical MRI, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
- *Correspondence: Greetje Vande Velde,
| |
Collapse
|
4
|
Shi L, Herrmann J, Bou Jawde S, Bates JHT, Nia HT, Suki B. Modeling the influence of gravity and the mechanical properties of elastin and collagen fibers on alveolar and lung pressure-volume curves. Sci Rep 2022; 12:12280. [PMID: 35853981 PMCID: PMC9294799 DOI: 10.1038/s41598-022-16650-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Accepted: 07/13/2022] [Indexed: 11/13/2022] Open
Abstract
The relationship between pressure (P) and volume (V) in the human lung has been extensively studied. However, the combined effects of gravity and the mechanical properties of elastin and collagen on alveolar and lung P–V curves during breathing are not well understood. Here, we extended a previously established thick-walled spherical model of a single alveolus with wavy collagen fibers during positive pressure inflation. First, we updated the model for negative pressure-driven inflation that allowed incorporation of a gravity-induced pleural pressure gradient to predict how the static alveolar P–V relations vary spatially throughout an upright human lung. Second, by introducing dynamic surface tension and collagen viscoelasticity, we computed the hysteresis loop of the lung P–V curve. The model was tested by comparing its predicted regional ventilation to literature data, which offered insight into the effects of microgravity on ventilation. The model has also produced novel testable predictions for future experiments about the variation of mechanical stresses in the septal walls and the contribution of collagen and elastin fibers to the P–V curve and throughout the lung. The model may help us better understand how mechanical stresses arising from breathing and pleural pressure variations affect regional cellular mechanotransduction in the lung.
Collapse
Affiliation(s)
- Linzheng Shi
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA
| | - Jacob Herrmann
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA
| | - Samer Bou Jawde
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA
| | - Jason H T Bates
- Department of Medicine, University of Vermont, Burlington, VT, USA
| | - Hadi T Nia
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA
| | - Béla Suki
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA.
| |
Collapse
|
5
|
Regional Gas Transport During Conventional and Oscillatory Ventilation Assessed by Xenon-Enhanced Computed Tomography. Ann Biomed Eng 2021; 49:2377-2388. [PMID: 33948747 DOI: 10.1007/s10439-021-02767-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 03/12/2021] [Indexed: 01/16/2023]
Abstract
Enhanced intrapulmonary gas transport enables oscillatory ventilation modalities to support gas exchange using extremely low tidal volumes at high frequencies. However, it is unknown whether gas transport rates can be improved by combining multiple frequencies of oscillation simultaneously. The goal of this study was to investigate distributed gas transport in vivo during multi-frequency oscillatory ventilation (MFOV) as compared with conventional mechanical ventilation (CMV) or high-frequency oscillatory ventilation (HFOV). We hypothesized that MFOV would result in more uniform rates of gas transport compared to HFOV, measured using contrast-enhanced CT imaging during wash-in of xenon gas. In 13 pigs, xenon wash-in equilibration rates were comparable between CMV and MFOV, but 21 to 39% slower for HFOV. By contrast, the root-mean-square delivered volume was lowest for MFOV, increased by 70% during HFOV and 365% during CMV. Overall gas transport heterogeneity was similar across all modalities, but gravitational gradients and regional patchiness of specific ventilation contributed to regional ventilation heterogeneity, depending on ventilator modality. We conclude that MFOV combines benefits of low lung stretch, similar to HFOV, but with fast rates of gas transport, similar to CMV.
Collapse
|
6
|
Functional lung imaging with synchrotron radiation: Methods and preclinical applications. Phys Med 2020; 79:22-35. [PMID: 33070047 DOI: 10.1016/j.ejmp.2020.10.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 09/30/2020] [Accepted: 10/03/2020] [Indexed: 01/05/2023] Open
Abstract
Many lung disease processes are characterized by structural and functional heterogeneity that is not directly appreciable with traditional physiological measurements. Experimental methods and lung function modeling to study regional lung function are crucial for better understanding of disease mechanisms and for targeting treatment. Synchrotron radiation offers useful properties to this end: coherence, utilized in phase-contrast imaging, and high flux and a wide energy spectrum which allow the selection of very narrow energy bands of radiation, thus allowing imaging at very specific energies. K-edge subtraction imaging (KES) has thus been developed at synchrotrons for both human and small animal imaging. The unique properties of synchrotron radiation extend X-ray computed tomography (CT) capabilities to quantitatively assess lung morphology, and also to map regional lung ventilation, perfusion, inflammation and biomechanical properties, with microscopic spatial resolution. Four-dimensional imaging, allows the investigation of the dynamics of regional lung functional parameters simultaneously with structural deformation of the lung as a function of time. This review summarizes synchrotron radiation imaging methods and overviews examples of its application in the study of disease mechanisms in preclinical animal models, as well as the potential for clinical translation both through the knowledge gained using these techniques and transfer of imaging technology to laboratory X-ray sources.
Collapse
|
7
|
Hopkins SR. Ventilation/Perfusion Relationships and Gas Exchange: Measurement Approaches. Compr Physiol 2020; 10:1155-1205. [PMID: 32941684 DOI: 10.1002/cphy.c180042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Ventilation-perfusion ( V ˙ A / Q ˙ ) matching, the regional matching of the flow of fresh gas to flow of deoxygenated capillary blood, is the most important mechanism affecting the efficiency of pulmonary gas exchange. This article discusses the measurement of V ˙ A / Q ˙ matching with three broad classes of techniques: (i) those based in gas exchange, such as the multiple inert gas elimination technique (MIGET); (ii) those derived from imaging techniques such as single-photon emission computed tomography (SPECT), positron emission tomography (PET), magnetic resonance imaging (MRI), computed tomography (CT), and electrical impedance tomography (EIT); and (iii) fluorescent and radiolabeled microspheres. The focus is on the physiological basis of these techniques that provide quantitative information for research purposes rather than qualitative measurements that are used clinically. The fundamental equations of pulmonary gas exchange are first reviewed to lay the foundation for the gas exchange techniques and some of the imaging applications. The physiological considerations for each of the techniques along with advantages and disadvantages are briefly discussed. © 2020 American Physiological Society. Compr Physiol 10:1155-1205, 2020.
Collapse
Affiliation(s)
- Susan R Hopkins
- Departments of Medicine and Radiology, University of California, San Diego, California, USA
| |
Collapse
|
8
|
Clark AR, Burrowes KS, Tawhai MH. Ventilation/Perfusion Matching: Of Myths, Mice, and Men. Physiology (Bethesda) 2019; 34:419-429. [PMID: 31577170 PMCID: PMC7002871 DOI: 10.1152/physiol.00016.2019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 07/01/2019] [Accepted: 07/08/2019] [Indexed: 11/22/2022] Open
Abstract
Despite a huge range in lung size between species, there is little measured difference in the ability of the lung to provide a well-matched air flow (ventilation) to blood flow (perfusion) at the gas exchange tissue. Here, we consider the remarkable similarities in ventilation/perfusion matching between species through a biophysical lens and consider evidence that matching in large animals is dominated by gravity but in small animals by structure.
Collapse
Affiliation(s)
- Alys R Clark
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Kelly S Burrowes
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Merryn H Tawhai
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
9
|
Thomlinson W, Elleaume H, Porra L, Suortti P. K-edge subtraction synchrotron X-ray imaging in bio-medical research. Phys Med 2018; 49:58-76. [DOI: 10.1016/j.ejmp.2018.04.389] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 04/12/2018] [Accepted: 04/16/2018] [Indexed: 11/26/2022] Open
|
10
|
Ambrisko TD, Schramel JP, Auer U, Moens YPS. Impact of four different recumbencies on the distribution of ventilation in conscious or anaesthetized spontaneously breathing beagle dogs: An electrical impedance tomography study. PLoS One 2017; 12:e0183340. [PMID: 28922361 PMCID: PMC5603158 DOI: 10.1371/journal.pone.0183340] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 08/02/2017] [Indexed: 11/18/2022] Open
Abstract
The aim was to examine the effects of recumbency and anaesthesia on distribution of ventilation in beagle dogs using Electrical Impedance Tomography (EIT). Nine healthy beagle dogs, aging 3.7±1.7 (mean±SD) years and weighing 16.3±1.6 kg, received a series of treatments in a fixed order on a single occasion. Conscious dogs were positioned in right lateral recumbency (RLR) and equipped with 32 EIT electrodes around the thorax. Following five minutes of equilibration, two minutes of EIT recordings were made in each recumbency in the following order: RLR, dorsal (DR), left (LLR) and sternal (SR). The dogs were then positioned in RLR, premedicated (medetomidine 0.01, midazolam 0.1, butorphanol 0.1 mg kg-1 iv) and pre-oxygenated. Fifteen minutes later anaesthesia was induced with 1 mg kg-1 propofol iv and maintained with propofol infusion (0.1–0.2 mg kg-1 minute-1 iv). After induction, the animals were intubated and allowed to breathe spontaneously (FIO2 = 1). Recordings of EIT were performed again in four recumbencies similarly to conscious state. Centre of ventilation (COV) and global inhomogeneity (GI) index were calculated from the functional EIT images. Repeated-measures ANOVA and Bonferroni tests were used for statistical analysis (p < 0.05). None of the variables changed in the conscious state. During anaesthesia left-to-right COV increased from 46.8±2.8% in DR to 49.8±2.9% in SR indicating a right shift, and ventral-to-dorsal COV increased from 49.8±1.7% in DR to 51.8±1.1% in LLR indicating a dorsal shift in distribution of ventilation. Recumbency affected distribution of ventilation in anaesthetized but not in conscious dogs. This can be related to loss of respiratory muscle tone (e.g. diaphragm) and changes in thoracic shape. Changing position of thoraco-abdominal organs under the EIT belt should be considered as alternative explanation of these findings.
Collapse
Affiliation(s)
- Tamas D Ambrisko
- Anaesthesiology and Perioperative Intensive-Care Medicine, Department for Companion Animals and Horses, University of Veterinary Medicine, Vienna, Austria
| | - Johannes P Schramel
- Anaesthesiology and Perioperative Intensive-Care Medicine, Department for Companion Animals and Horses, University of Veterinary Medicine, Vienna, Austria
| | - Ulrike Auer
- Anaesthesiology and Perioperative Intensive-Care Medicine, Department for Companion Animals and Horses, University of Veterinary Medicine, Vienna, Austria
| | - Yves P S Moens
- Anaesthesiology and Perioperative Intensive-Care Medicine, Department for Companion Animals and Horses, University of Veterinary Medicine, Vienna, Austria
| |
Collapse
|
11
|
Zhang GG, Latifi K, Du K, Reinhardt JM, Christensen GE, Ding K, Feygelman V, Moros EG. Evaluation of the ΔV 4D CT ventilation calculation method using in vivo xenon CT ventilation data and comparison to other methods. J Appl Clin Med Phys 2016; 17:550-560. [PMID: 27074479 PMCID: PMC5874808 DOI: 10.1120/jacmp.v17i2.5985] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 11/30/2015] [Accepted: 11/25/2015] [Indexed: 12/25/2022] Open
Abstract
Ventilation distribution calculation using 4D CT has shown promising potential in several clinical applications. This study evaluated the direct geometric ventilation calculation method, namely the ΔV method, with xenon-enhanced CT (XeCT) ventilation data from four sheep, and compared it with two other published meth-ods, the Jacobian and the Hounsfield unit (HU) methods. Spearman correlation coefficient (SCC) and Dice similarity coefficient (DSC) were used for the evaluation and comparison. The average SCC with one standard deviation was 0.44 ± 0.13 with a range between 0.29 and 0.61 between the XeCT and ΔV ventilation distributions. The average DSC value for lower 30% ventilation volumes between the XeCT and ΔV ventilation distributions was 0.55 ± 0.07 with a range between 0.48 and 0.63. Ventilation difference introduced by deformable image registration errors improved with smoothing. In conclusion, ventilation distributions generated using ΔV-4D CT and deformable image registration are in reasonably agreement with the in vivo XeCT measured ventilation distribution.
Collapse
|
12
|
Pennati F, Salito C, Baroni G, Woods J, Aliverti A. Comparison between multivolume CT-based surrogates of regional ventilation in healthy subjects. Acad Radiol 2014; 21:1268-75. [PMID: 25126974 DOI: 10.1016/j.acra.2014.05.022] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Revised: 05/22/2014] [Accepted: 05/27/2014] [Indexed: 01/14/2023]
Abstract
RATIONALE AND OBJECTIVES The assessment of regional ventilation is of critical importance when investigating lung function during disease progression and planning of pulmonary interventions. Recently, different computed tomography (CT)-based parameters have been proposed as surrogates of lung ventilation. The aim of the present study was to compare these parameters, namely variations of density (ΔHU), specific volume (sVol), and specific gas volume (ΔSVg) between different lung volumes, in relation to their topographic distribution within the lung. MATERIALS AND METHODS Ten healthy volunteers were scanned via high-resolution CT at residual volume (RV) and total lung capacity (TLC); ΔHU, sVol, and ΔSVg were mapped voxel by voxel after registering TLC onto RV. Variations of the three parameters along the vertical and horizontal directions were analyzed. RESULTS Along the vertical direction (from ventral to dorsal regions), a strong dependence on gravity was found in ΔHU and sVol, with greater values in the dorsal regions of the lung (P < .001), whereas ΔSVg was more homogeneously distributed within the lung. Conversely, along the caudocranial direction (from lung bases to apexes) where no gravitational gradient is present, the three parameters behaved similarly, with lower values at the apices. CONCLUSIONS ΔHU, sVol, and ΔSVg behave differently along the gravity direction. As the greater amount of air delivered to the dependent portion of the lung supplies a larger number of alveoli, the amount of gas delivered to alveoli compared to the mass of tissue is not gravity dependent. The minimization of gravity dependence in the distribution of ventilation when using ΔSVg suggests that this parameter is more reliable to discriminate healthy from pathologic regions.
Collapse
Affiliation(s)
- Francesca Pennati
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, P.zza L. da Vinci, 32, 20133 Milano, Italy
| | - Caterina Salito
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, P.zza L. da Vinci, 32, 20133 Milano, Italy
| | - Guido Baroni
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, P.zza L. da Vinci, 32, 20133 Milano, Italy
| | - Jason Woods
- Pulmonary Imaging Research Center, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio
| | - Andrea Aliverti
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, P.zza L. da Vinci, 32, 20133 Milano, Italy.
| |
Collapse
|
13
|
Chung YE, Hong SR, Lee MJ, Lee M, Lee HJ. Krypton-enhanced ventilation CT with dual energy technique: Experimental study for optimal krypton concentration. Exp Lung Res 2014; 40:439-46. [DOI: 10.3109/01902148.2014.946630] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
14
|
Park HW, Jung JW, Kim KM, Kim TW, Lee SH, Lee CH, Goo JM, Min KU, Cho SH. Xenon ventilation computed tomography and the management of asthma in the elderly. Respirology 2014; 19:389-95. [PMID: 24512222 DOI: 10.1111/resp.12242] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2012] [Revised: 12/19/2012] [Accepted: 11/12/2013] [Indexed: 11/27/2022]
Abstract
BACKGROUND AND OBJECTIVE Xenon ventilation computed tomography (CT) has shown potential in assessing the regional ventilation status in subjects with asthma. The purpose of this study was to evaluate the usefulness of xenon ventilation CT in the management of asthma in the elderly. METHODS Treatment-naïve asthmatics aged 65 years or older were recruited. Before initiation of medication, spirometry with bronchodilator (BD) reversibility, questionnaires to assess the severity of symptoms including a visual analogue scale (VAS), tests to evaluate cognitive function and mood, and xenon ventilation CT were performed. Xenon gas trapping (XT) on xenon ventilation CT represents an area where inhaled xenon gas was not expired and was trapped. Symptoms and lung functions were measured again after the 12-week treatment. RESULTS A total of 30 elderly asthmatics were enrolled. The severity of dyspnoea measured by the VAS showed a significant correlation with the total number of areas of XT on the xenon ventilation CT taken in the pre-BD wash-out phase (r = -0.723, P < 0.001). The total number of areas of XT significantly decreased after BD inhalation, and differences in the total number of areas of XT (between the pre- and post-BD wash-out phases) at baseline showed significant correlations with the per cent increases in forced expiratory volume in 1 s after subsequent anti-asthma treatment (r = -0.775, P < 0.001). CONCLUSIONS Xenon ventilation CT may be an objective and promising tool in the measurement of dyspnoea and prediction of the treatment response in elderly asthmatics.
Collapse
Affiliation(s)
- Heung-Woo Park
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea; Institute of Allergy and Clinical Immunology, Seoul National University Medical Research Center, Seoul, Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Du K, Bayouth JE, Ding K, Christensen GE, Cao K, Reinhardt JM. Reproducibility of intensity-based estimates of lung ventilation. Med Phys 2014; 40:063504. [PMID: 23718615 DOI: 10.1118/1.4805106] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Lung function depends on lung expansion and contraction during the respiratory cycle. Respiratory-gated CT imaging and image registration can be used to estimate the regional lung volume change by observing CT voxel density changes during inspiration or expiration. In this study, the authors examine the reproducibility of intensity-based estimates of lung tissue expansion and contraction in three mechanically ventilated sheep and ten spontaneously breathing humans. The intensity-based estimates are compared to the estimates of lung function derived from image registration deformation field. METHODS 4DCT data set was acquired for a cohort of spontaneously breathing humans and anesthetized and mechanically ventilated sheep. For each subject, two 4DCT scans were performed with a short time interval between acquisitions. From each 4DCT data set, an image pair consisting of a volume reconstructed near end inspiration and a volume reconstructed near end exhalation was selected. The end inspiration and end exhalation images were registered using a tissue volume preserving deformable registration algorithm. The CT density change in the registered image pair was used to compute intensity-based specific air volume change (SAC) and the intensity-based Jacobian (IJAC), while the transformation-based Jacobian (TJAC) was computed directly from the image registration deformation field. IJAC is introduced to make the intensity-based and transformation-based methods comparable since SAC and Jacobian may not be associated with the same physiological phenomenon and have different units. Scan-to-scan variations in respiratory effort were corrected using a global scaling factor for normalization. A gamma index metric was introduced to quantify voxel-by-voxel reproducibility considering both differences in ventilation and distance between matching voxels. The authors also tested how different CT prefiltering levels affected intensity-based ventilation reproducibility. RESULTS Higher reproducibility was found for anesthetized mechanically ventilated animals than for the humans for both the intensity-based (IJAC) and transformation-based (TJAC) ventilation estimates. The human IJAC maps had scan-to-scan correlation coefficients of 0.45 ± 0.14, a gamma pass rate 70 ± 8 without normalization and 75 ± 5 with normalization. The human TJAC maps had correlation coefficients 0.81 ± 0.10, a gamma pass rate 86 ± 11 without normalization and 93 ± 4 with normalization. The gamma pass rate and correlation coefficient of the IJAC maps gradually increased with increased smoothing, but were still much lower than those of the TJAC maps. CONCLUSIONS The transformation-based ventilation maps show better reproducibility than the intensity-based maps, especially in human subjects. Reproducibility was also found to depend on variations in respiratory effort; all techniques were better when applied to images from mechanically ventilated sheep compared to spontaneously breathing human subjects. Nevertheless, intensity-based techniques applied to mechanically ventilated sheep were less reproducible than the transformation-based applied to spontaneously breathing humans, suggesting the method used to determine ventilation maps is important. Prefiltering of the CT images may help to improve the reproducibility of the intensity-based ventilation estimates, but even with filtering the reproducibility of the intensity-based ventilation estimates is not as good as that of transformation-based ventilation estimates.
Collapse
Affiliation(s)
- Kaifang Du
- Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa 52242, USA
| | | | | | | | | | | |
Collapse
|
16
|
Glenny RW, Robertson HT. Spatial distribution of ventilation and perfusion: mechanisms and regulation. Compr Physiol 2013; 1:375-95. [PMID: 23737178 DOI: 10.1002/cphy.c100002] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
With increasing spatial resolution of regional ventilation and perfusion, it has become more apparent that ventilation and blood flow are quite heterogeneous in the lung. A number of mechanisms contribute to this regional variability, including hydrostatic gradients, pleural pressure gradients, lung compressibility, and the geometry of the airway and vascular trees. Despite this marked heterogeneity in both ventilation and perfusion, efficient gas exchange is possible through the close regional matching of the two. Passive mechanisms, such as the shared effect of gravity and the matched branching of vascular and airway trees, create efficient gas exchange through the strong correlation between ventilation and perfusion. Active mechanisms that match local ventilation and perfusion play little if no role in the normal healthy lung but are important under pathologic conditions.
Collapse
Affiliation(s)
- Robb W Glenny
- Department of Medicine, University of Washington, USA.
| | | |
Collapse
|
17
|
Lilburn DML, Hughes-Riley T, Six JS, Stupic KF, Shaw DE, Pavlovskaya GE, Meersmann T. Validating excised rodent lungs for functional hyperpolarized xenon-129 MRI. PLoS One 2013; 8:e73468. [PMID: 24023683 PMCID: PMC3758272 DOI: 10.1371/journal.pone.0073468] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Accepted: 07/21/2013] [Indexed: 12/15/2022] Open
Abstract
Ex vivo rodent lung models are explored for physiological measurements of respiratory function with hyperpolarized (hp) (129)Xe MRI. It is shown that excised lung models allow for simplification of the technical challenges involved and provide valuable physiological insights that are not feasible using in vivo MRI protocols. A custom designed breathing apparatus enables MR images of gas distribution on increasing ventilation volumes of actively inhaled hp (129)Xe. Straightforward hp (129)Xe MRI protocols provide residual lung volume (RV) data and permit for spatially resolved tracking of small hp (129)Xe probe volumes during the inhalation cycle. Hp (129)Xe MRI of lung function in the excised organ demonstrates the persistence of post mortem airway responsiveness to intravenous methacholine challenges. The presented methodology enables physiology of lung function in health and disease without additional regulatory approval requirements and reduces the technical and logistical challenges with hp gas MRI experiments. The post mortem lung functional data can augment histological measurements and should be of interest for drug development studies.
Collapse
Affiliation(s)
- David M. L. Lilburn
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Theodore Hughes-Riley
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Joseph S. Six
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Karl F. Stupic
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Dominick E. Shaw
- Nottingham Respiratory Research Unit, Nottingham City Hospital, Nottingham, United Kingdom
| | - Galina E. Pavlovskaya
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Thomas Meersmann
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| |
Collapse
|
18
|
Du K, Bayouth JE, Cao K, Christensen GE, Ding K, Reinhardt JM. Reproducibility of registration-based measures of lung tissue expansion. Med Phys 2013; 39:1595-608. [PMID: 22380392 DOI: 10.1118/1.3685589] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Lung function depends on lung expansion and contraction during the respiratory cycle. Respiratory-gated CT imaging and 3D image registration can be used to locally estimate lung tissue expansion and contraction (regional lung volume change) by computing the determinant of the Jacobian matrix of the image registration deformation field. In this study, the authors examine the reproducibility of Jacobian-based measures of lung tissue expansion in two repeat 4DCT acquisitions of mechanically ventilated sheep and free-breathing humans. METHODS 4DCT image data from three white sheep and nine human subjects were used for this analysis. In each case, two 4DCT studies were acquired for each subject within a short time interval. The animal subjects were anesthetized and mechanically ventilated, while the humans were awake and spontaneously breathing based on respiratory pacing audio cues. From each 4DCT data set, an image pair consisting of a volume reconstructed near end inspiration and a volume reconstructed near end exhalation was selected. The end inspiration and end exhalation images were registered using a tissue volume preserving deformable registration algorithm and the Jacobian of the registration deformation field was used to measure regional lung expansion. The Jacobian map from the baseline data set was compared to the Jacobian map from the followup data by measuring the voxel-by-voxel Jacobian ratio. RESULTS In the animal subjects, the mean Jacobian ratio (baseline scan Jacobian divided by followup scan Jacobian, voxel-by-voxel) was 0.9984±0.021 (mean ± standard deviation, averaged over the entire lung region). The mean Jacobian ratio was 1.0224±0.058 in the human subjects. The reproducibility of the Jacobian values was found to be strongly dependent on the reproducibility of the subject's respiratory effort and breathing pattern. CONCLUSIONS Lung expansion, a surrogate for lung function, can be assessed using two or more respiratory-gated CT image acquisitions. The results show that good reproducibility can be obtained in anesthetized, mechanically ventilated animals, but variations in respiratory effort and breathing patterns reduce reproducibility in spontaneously-breathing humans. The global linear normalization can globally compensate for breathing effort differences, but a homogeneous scaling does not account for differences in regional lung expansion rates. Additional work is needed to develop compensation procedures or normalization schemes that can account for local variations in lung expansion during respiration.
Collapse
Affiliation(s)
- Kaifang Du
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA
| | | | | | | | | | | |
Collapse
|
19
|
Emami K, Xu Y, Hamedani H, Profka H, Kadlecek S, Xin Y, Ishii M, Rizi RR. Accelerated fractional ventilation imaging with hyperpolarized Gas MRI. Magn Reson Med 2013; 70:1353-9. [PMID: 23400938 DOI: 10.1002/mrm.24582] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2012] [Revised: 10/24/2012] [Accepted: 11/12/2012] [Indexed: 11/11/2022]
Abstract
PURPOSE To investigate the utility of accelerated imaging to enhance multibreath fractional ventilation (r) measurement accuracy using hyperpolarized gas MRI. Undersampling shortens the breath-hold time, thereby reducing the O2 -induced signal decay and allows subjects to maintain a more physiologically relevant breathing pattern. Additionally, it may improve r estimation accuracy by reducing radiofrequency destruction of hyperpolarized gas. METHODS Image acceleration was achieved using an eight-channel phased array coil. Undersampled image acquisition was simulated in a series of ventilation images and data was reconstructed for various matrix sizes (48-128) using generalized auto-calibrating partially parallel acquisition. Parallel accelerated r imaging was also performed on five mechanically ventilated pigs. RESULTS Optimal acceleration factor was fairly invariable (2.0-2.2×) over the range of simulated resolutions. Estimation accuracy progressively improved with higher resolutions (39-51% error reduction). In vivo r values were not significantly different between the two methods: 0.27 ± 0.09, 0.35 ± 0.06, 0.40 ± 0.04 (standard) versus 0.23 ± 0.05, 0.34 ± 0.03, 0.37 ± 0.02 (accelerated); for anterior, medial, and posterior slices, respectively, whereas the corresponding vertical r gradients were significant (P < 0.001): 0.021 ± 0.007 (standard) versus 0.019 ± 0.005 (accelerated) (cm(-1) ). CONCLUSION Quadruple phased array coil simulations resulted in an optimal acceleration factor of ∼2× independent of imaging resolution. Results advocate undersampled image acceleration to improve accuracy of fractional ventilation measurement with hyperpolarized gas MRI.
Collapse
Affiliation(s)
- Kiarash Emami
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Huang TC, Hsiao CY, Chien CR, Liang JA, Shih TC, Zhang GG. IMRT treatment plans and functional planning with functional lung imaging from 4D-CT for thoracic cancer patients. Radiat Oncol 2013; 8:3. [PMID: 23281734 PMCID: PMC3552773 DOI: 10.1186/1748-717x-8-3] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2012] [Accepted: 12/29/2012] [Indexed: 12/25/2022] Open
Abstract
Background and purpose Currently, the inhomogeneity of the pulmonary function is not considered when treatment plans are generated in thoracic cancer radiotherapy. This study evaluates the dose of treatment plans on highly-functional volumes and performs functional treatment planning by incorporation of ventilation data from 4D-CT. Materials and methods Eleven patients were included in this retrospective study. Ventilation was calculated using 4D-CT. Two treatment plans were generated for each case, the first one without the incorporation of the ventilation and the second with it. The dose of the first plans was overlapped with the ventilation and analyzed. Highly-functional regions were avoided in the second treatment plans. Results For small targets in the first plans (PTV < 400 cc, 6 cases), all V5, V20 and the mean lung dose values for the highly-functional regions were lower than that of the total lung. For large targets, two out of five cases had higher V5 and V20 values for the highly-functional regions. All the second plans were within constraints. Conclusion Radiation treatments affect functional lung more seriously in large tumor cases. With compromise of dose to other critical organs, functional treatment planning to reduce dose in highly-functional lung volumes can be achieved
Collapse
Affiliation(s)
- Tzung-Chi Huang
- Department of Biomedical Imaging and Radiological Science, China Medical University, 91, Hsueh-Shih Road, Taichung City, Taiwan.
| | | | | | | | | | | |
Collapse
|
21
|
Introduction to 4D Motion Modeling and 4D Radiotherapy. 4D MODELING AND ESTIMATION OF RESPIRATORY MOTION FOR RADIATION THERAPY 2013. [DOI: 10.1007/978-3-642-36441-9_1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
22
|
Li B, Christensen GE, Hoffman EA, McLennan G, Reinhardt JM. Establishing a normative atlas of the human lung: computing the average transformation and atlas construction. Acad Radiol 2012; 19:1368-81. [PMID: 22951110 DOI: 10.1016/j.acra.2012.04.025] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2012] [Revised: 03/06/2012] [Accepted: 04/23/2012] [Indexed: 10/28/2022]
Abstract
RATIONALE AND OBJECTIVES To establish the range of normal for quantitative computed tomography (CT)-based measures of lung structure and function, we seek to develop methods for matching pulmonary structures across individuals and establishing a normative human lung atlas. MATERIALS AND METHODS In our previous work, we have presented a three-dimensional (3D) image registration method suitable for pulmonary atlas construction based on CT datasets. The method has been applied to a population of normative lungs in multiple experiments and, in each instance, has resulted in significant reductions in registration errors. This study is a continuation to our previous work by presenting a method for synthesizing a computerized human lung atlas from previously registered and matched 3D pulmonary CT datasets from a population of normative subjects. Our method consists of defining the origin of the atlas coordinate system; defining the nomenclature and labels for anatomical structures within the atlas system; computing the average transformation based on the displacement fields to register individual subject to the common template subject; constructing the atlas by deforming the template with the average transformation; and calculating shape variations within the population. RESULTS The feasibility of pulmonary atlas construction was evaluated using CT datasets from 20 normal volunteers. Substantial reductions in shape variability were demonstrated. In addition, the constructed atlas depends only slightly on a specific subject being selected as the template. These results indicate the framework is a robust and valid method for pulmonary atlas construction based on CT scans. The atlas consists of a grayscale CT dataset of the template, a labeled mask dataset of the template (ie, lungs, lobes, and lobar fissures are labeled with different gray levels), a data set representing the population's average shape, datasets representing the population's shape variations (ie, the magnitude of standard deviation), a data structure to contain the labels and coordinates of major airway branchpoints, and the labels of the mask dataset, and a reference coordinate system for each lung. CONCLUSION A computerized human lung atlas representing by the average shape of a population of twenty normal subjects was constructed and visualized. The atlas provides a basis for establishing regional ranges of normative values for structural and functional measures of the human lung. In the future, we plan to use the computerized human lung atlas to help detect and quantify early signs of lung pathology.
Collapse
|
23
|
Ding K, Cao K, Fuld MK, Du K, Christensen GE, Hoffman EA, Reinhardt JM. Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT. Med Phys 2012; 39:5084-98. [PMID: 22894434 DOI: 10.1118/1.4736808] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Regional lung volume change as a function of lung inflation serves as an index of parenchymal and airway status as well as an index of regional ventilation and can be used to detect pathologic changes over time. In this paper, the authors propose a new regional measure of lung mechanics-the specific air volume change by corrected Jacobian. The authors compare this new measure, along with two existing registration based measures of lung ventilation, to a regional ventilation measurement derived from xenon-CT (Xe-CT) imaging. METHODS 4DCT and Xe-CT datasets from four adult sheep are used in this study. Nonlinear, 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration. Approximately 200 annotated anatomical points are used as landmarks to evaluate registration accuracy. Three different registration based measures of regional lung mechanics are derived and compared: the specific air volume change calculated from the Jacobian (SAJ); the specific air volume change calculated by the corrected Jacobian (SACJ); and the specific air volume change by intensity change (SAI). The authors show that the commonly used SAI measure can be derived from the direct SAJ measure by using the air-tissue mixture model and assuming there is no tissue volume change between the end inspiration and end expiration datasets. All three ventilation measures are evaluated by comparing to Xe-CT estimates of regional ventilation. RESULTS After registration, the mean registration error is on the order of 1 mm. For cubical regions of interest (ROIs) in cubes with size 20 mm × 20 mm × 20 mm, the SAJ and SACJ measures show significantly higher correlation (linear regression, average r(2) = 0.75 and r(2) = 0.82) with the Xe-CT based measure of specific ventilation (sV) than the SAI measure. For ROIs in slabs along the ventral-dorsal vertical direction with size of 150 mm × 8 mm × 40 mm, the SAJ, SACJ, and SAI all show high correlation (linear regression, average r(2) = 0.88, r(2) = 0.92, and r(2) = 0.87) with the Xe-CT based sV without significant differences when comparing between the three methods. The authors demonstrate a linear relationship between the difference of specific air volume change and difference of tissue volume in all four animals (linear regression, average r(2) = 0.86). CONCLUSIONS Given a deformation field by an image registration algorithm, significant differences between the SAJ, SACJ, and SAI measures were found at a regional level compared to the Xe-CT sV in four sheep that were studied. The SACJ introduced here, provides better correlations with Xe-CT based sV than the SAJ and SAI measures, thus providing an improved surrogate for regional ventilation.
Collapse
Affiliation(s)
- Kai Ding
- Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa 52242, USA
| | | | | | | | | | | | | |
Collapse
|
24
|
Emami K, Xu Y, Hamedani H, Xin Y, Profka H, Rajaei J, Kadlecek S, Ishii M, Rizi RR. Multislice fractional ventilation imaging in large animals with hyperpolarized gas MRI. NMR IN BIOMEDICINE 2012; 25:1015-1025. [PMID: 22290603 PMCID: PMC3362674 DOI: 10.1002/nbm.2763] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Revised: 11/17/2011] [Accepted: 11/22/2011] [Indexed: 05/31/2023]
Abstract
The noninvasive assessment of regional lung ventilation is of critical importance in the quantification of the severity of disease and evaluation of response to therapy in many pulmonary diseases. This work presents, for the first time, the implementation of a hyperpolarized (HP) gas MRI technique to measure whole-lung regional fractional ventilation (r) in Yorkshire pigs (n = 5) through the use of a gas mixing and delivery device in the supine position. The proposed technique utilizes a series of back-to-back HP gas breaths with images acquired during short end-inspiratory breath-holds. In order to decouple the radiofrequency pulse decay effect from the ventilatory signal build-up in the airways, the regional distribution of the flip angle (α) was estimated in the imaged slices by acquiring a series of back-to-back images with no interscan time delay during a breath-hold at the tail end of the ventilation sequence. Analysis was performed to assess the sensitivity of the multislice ventilation model to noise, oxygen and the number of flip angle images. The optimal α value was determined on the basis of the minimization of the error in r estimation: α(opt) = 5-6º for the set of acquisition parameters in pigs. The mean r values for the group of pigs were 0.27 ± 0.09, 0.35 ± 0.06 and 0.40 ± 0.04 for the ventral, middle and dorsal slices, respectively (excluding conductive airways r 0.9). A positive gravitational (ventral-dorsal) ventilation gradient effect was present in all animals. The trachea and major conductive airways showed a uniform near-unity r value, with progressively smaller values corresponding to smaller diameter airways, and ultimately leading to lung parenchyma. The results demonstrate the feasibility of the measurement of the fractional ventilation in large species, and provide a platform to address the technical challenges associated with long breathing time scales through the optimization of acquisition parameters in species with a pulmonary physiology very similar to that of humans.
Collapse
Affiliation(s)
- Kiarash Emami
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Regional pulmonary inflammation in an endotoxemic ovine acute lung injury model. Respir Physiol Neurobiol 2012; 183:149-58. [PMID: 22728442 DOI: 10.1016/j.resp.2012.06.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2012] [Revised: 06/08/2012] [Accepted: 06/11/2012] [Indexed: 11/23/2022]
Abstract
The regional distribution of inflammation during acute lung injury (ALI) is not well known. In an ovine ALI model we studied regional alveolar inflammation, surfactant composition, and CT-derived regional specific volume change (sVol) and specific compliance (sC). 18 ventilated adult sheep received IV lipopolysaccharide (LPS) until severe ALI was achieved. Blood and bronchoalveolar lavage (BAL) samples from apical and basal lung regions were obtained at baseline and injury time points, for analysis of cytokines (IL-6, IL-1β), BAL protein and surfactant composition. Whole lung CT images were obtained in 4 additional sheep. BAL protein and IL-1β were significantly higher in injured apical vs. basal regions. No significant regional surfactant composition changes were observed. Baseline sVol and sC were lower in apex vs. base; ALI enhanced this cranio-caudal difference, reaching statistical significance only for sC. This study suggests that apical lung regions show greater inflammation than basal ones during IV LPS-induced ALI which may relate to differences in regional mechanical events.
Collapse
|
26
|
Simon BA, Kaczka DW, Bankier AA, Parraga G. What can computed tomography and magnetic resonance imaging tell us about ventilation? J Appl Physiol (1985) 2012; 113:647-57. [PMID: 22653989 DOI: 10.1152/japplphysiol.00353.2012] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
This review provides a summary of pulmonary functional imaging approaches for determining pulmonary ventilation, with a specific focus on multi-detector x-ray computed tomography and magnetic resonance imaging (MRI). We provide the important functional definitions of pulmonary ventilation typically used in medicine and physiology and discuss the fact that some of the imaging literature describes gas distribution abnormalities in pulmonary disease that may or may not be related to the physiological definition or clinical interpretation of ventilation. We also review the current state-of-the-field in terms of the key physiological questions yet unanswered related to ventilation and gas distribution in lung disease. Current and emerging imaging research methods are described, including their strengths and the challenges that remain to translate these methods to more wide-spread research and clinical use. We also examine how computed tomography and MRI might be used in the future to gain more insight into gas distribution and ventilation abnormalities in pulmonary disease.
Collapse
Affiliation(s)
- Brett A Simon
- Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA
| | | | | | | |
Collapse
|
27
|
Robertson HT, Buxton RB. Imaging for lung physiology: what do we wish we could measure? J Appl Physiol (1985) 2012; 113:317-27. [PMID: 22582217 DOI: 10.1152/japplphysiol.00146.2012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The role of imaging as a tool for investigating lung physiology is growing at an accelerating pace. Looking forward, we wished to identify unresolved issues in lung physiology that might realistically be addressed by imaging methods in development or imaging approaches that could be considered. The role of imaging is framed in terms of the importance of good spatial and temporal resolution and the types of questions that could be addressed as these technical capabilities improve. Recognizing that physiology is fundamentally a quantitative science, a recurring emphasis is on the need for imaging methods that provide reliable measurements of specific physiological parameters. The topics included necessarily reflect our perspective on what are interesting questions and are not meant to be a comprehensive review. Nevertheless, we hope that this essay will be a spur to physiologists to think about how imaging could usefully be applied in their research and to physical scientists developing new imaging methods to attack challenging questions imaging could potentially answer.
Collapse
Affiliation(s)
- H Thomas Robertson
- Department of Medicine, University of Washington, Seattle, WA 98195, USA.
| | | |
Collapse
|
28
|
Couch MJ, Ouriadov A, Santyr GE. Regional ventilation mapping of the rat lung using hyperpolarized129Xe magnetic resonance imaging. Magn Reson Med 2012; 68:1623-31. [DOI: 10.1002/mrm.24152] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2011] [Revised: 11/17/2011] [Accepted: 12/14/2011] [Indexed: 11/11/2022]
|
29
|
Honda N, Osada H, Watanabe W, Nakayama M, Nishimura K, Krauss B, Otani K. Imaging of Ventilation with Dual-Energy CT during Breath Hold after Single Vital-Capacity Inspiration of Stable Xenon. Radiology 2012; 262:262-8. [DOI: 10.1148/radiol.11110569] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
30
|
Santyr GE, Couch MJ, Lam WW, Ouriadov A, Drangova M, McCormack DG, Holdsworth DW. Comparison of hyperpolarized (3)He MRI with Xe-enhanced computed tomography imaging for ventilation mapping of rat lung. NMR IN BIOMEDICINE 2011; 24:1073-1080. [PMID: 21274963 DOI: 10.1002/nbm.1659] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2010] [Revised: 11/16/2010] [Accepted: 12/02/2010] [Indexed: 05/30/2023]
Abstract
Lung ventilation was mapped in five healthy Brown Norway rats (210-377 g) using both hyperpolarized (3)He MRI and Xe-enhanced computed tomography (Xe-CT) under similar ventilator conditions. Whole-lung measurements of ventilation r obtained with (3)He MRI were not significantly different from those obtained from Xe-CT (p = 0.1875 by Wilcoxon matched pairs test). The ventilation parameter r is defined as the fraction of refreshed gas per unit volume per breath. Regional ventilation was also measured in four regions of the lung using both methods. A two-tailed paired t-test was performed for each region, yielding p > 0.05 for all but the upper portion of the right lung. The distribution of regional ventilation was evaluated by calculating ventilation gradients in the superior/inferior (S/I) direction. The average S/I gradient obtained using the (3)He MRI method was found to be 0.17 ± 0.04 cm(-1) , whereas the average S/I gradient obtained using the Xe-CT method was found to be 0.016 ± 0.005 cm(-1) . In general, S/I ventilation gradients obtained from both methods were significantly different from each other (p = 0.0019 by two-tailed paired t-test). These regional differences in ventilation measurements may be caused by the manner in which the gas contrast agents distribute physiologically and/or by the imaging modality.
Collapse
Affiliation(s)
- Giles E Santyr
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada.
| | | | | | | | | | | | | |
Collapse
|
31
|
Three-dimensional characterization of regional lung deformation. J Biomech 2011; 44:2489-95. [PMID: 21802086 DOI: 10.1016/j.jbiomech.2011.06.009] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2010] [Revised: 06/06/2011] [Accepted: 06/15/2011] [Indexed: 11/24/2022]
Abstract
The deformation of the lung during inspiration and expiration involves regional variations in volume change and orientational preferences. Studies have reported techniques for measuring the displacement field in the lung based on imaging or image registration. However, means of interpreting all the information in the displacement field in a physiologically relevant manner is lacking. We propose three indices of lung deformation that are determinable from the displacement field: the Jacobian--a measure of volume change, the anisotropic deformation index--a measure of the magnitude of directional preference in volume change and a slab-rod index--a measure of the nature of directional preference in volume change. To demonstrate the utility of these indices, they were determined for six human subjects using deformable image registration on static CT images, registered from FRC to TLC. Volume change was elevated in the inferior-dorsal region as should be expected for breathing in the supine position. The anisotropic deformation index was elevated in the inferior region owing to proximity to the diaphragm and in the lobar fissures owing to sliding. Vessel regions in the lung had a significantly rod-like deformation compared to the whole lung. Compared to upper lobes, lower lobes exhibited significantly greater volume change (19.4% and 21.3% greater in the right and left lungs on average; p<0.005) and anisotropy in deformation (26.3% and 21.8% greater in the right and left lungs on average; p<0.05) with remarkable consistency across subjects. The developed deformation indices lend themselves to exhaustive and physiologically intuitive interpretations of the displacement fields in the lung determined through image-registration techniques or finite element simulations.
Collapse
|
32
|
Affiliation(s)
- Ching-Long Lin
- Department of Mechanical and Industrial Engineering, The University of Iowa, Iowa City, IA 52242, USA.
| | | | | | | |
Collapse
|
33
|
Lung imaging in asthmatic patients: the picture is clearer. J Allergy Clin Immunol 2011; 128:467-78. [PMID: 21636118 DOI: 10.1016/j.jaci.2011.04.051] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2010] [Revised: 04/10/2011] [Accepted: 04/18/2011] [Indexed: 01/11/2023]
Abstract
Imaging of the lungs in patients with asthma has evolved dramatically over the last decade with sophisticated techniques, such as computed tomography, magnetic resonance imaging, positron emission tomography, and single photon emission computed tomography. New insights into current and future modalities for imaging in asthmatic patients and their application are discussed to potentially shed a clearer picture of the underlying pathophysiology of asthma, especially severe asthma, and the proposed clinical utility of imaging in patients with this common disease.
Collapse
|
34
|
Tawhai MH, Lin CL. Image-based modeling of lung structure and function. J Magn Reson Imaging 2011; 32:1421-31. [PMID: 21105146 DOI: 10.1002/jmri.22382] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
The current state-of-the-art in image-based modeling allows derivation of patient-specific models of the lung, lobes, airways, and pulmonary vascular trees. The application of traditional engineering analyses of fluid and structural mechanics to image-based subject-specific models has the potential to provide new insight into structure-function relationships in the individual via functional interpretation that complements imaging and experimental studies. Three major issues that are encountered in studies of airflow through the bronchial airways are the representation of airway geometry, the imposition of physiological boundary conditions, and the treatment of turbulence. Here we review some efforts to resolve each of these issues, with particular focus on image-based models that have been developed to simulate airflow from the mouth to the terminal bronchiole, and subjected to physiologically meaningful boundary conditions via image registration and soft-tissue mechanics models.
Collapse
Affiliation(s)
- Merryn H Tawhai
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
| | | |
Collapse
|
35
|
Tawhai MH, Hoffman EA, Lin CL. The lung physiome: merging imaging-based measures with predictive computational models. WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE 2010; 1:61-72. [PMID: 20835982 DOI: 10.1002/wsbm.17] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Global measurements of the lung provided by standard pulmonary function tests do not give insight into the regional basis of lung function and lung disease. Advances in imaging methodologies, computer technologies, and subject-specific simulations are creating new opportunities to study structure-function relationships in the lung through multidisciplinary research. The digital Human Lung Atlas is an image-based resource compiled from male and female subjects spanning several decades of age. The Atlas comprises both structural and functional measures, and includes computational models derived to match individual subjects for personalized prediction of function. The computational models in the Atlas form part of the Lung Physiome project, which is an international effort to develop integrative models of lung function at all levels of biological organization. The computational models provide mechanistic interpretation of imaging measures; the Atlas provides structural data on which to base model geometry, and functional data against which to test hypotheses. The example of simulating airflow on a subject-specific basis is considered. Methods for deriving multiscale models of the airway geometry for individual subjects in the Atlas are outlined, and methods for modeling turbulent flows in the airway are reviewed.
Collapse
Affiliation(s)
- Merryn H Tawhai
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Eric A Hoffman
- Department of Radiology and Biomedical Engineering, The University of Iowa, Iowa City, IA 52242, USA
| | - Ching-Long Lin
- Department of Mechanical Engineering and IIHR, The University of Iowa, Iowa City, IA 52242, USA
| |
Collapse
|
36
|
Zhang LJ, Wang ZJ, Lu L, Zhu K, Chai X, Zhao YE, Peng J, Lu GM. Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits. Eur J Radiol 2010; 78:266-71. [PMID: 21109377 DOI: 10.1016/j.ejrad.2010.10.029] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2010] [Revised: 10/11/2010] [Accepted: 10/20/2010] [Indexed: 11/30/2022]
Abstract
PURPOSE To assess the feasibility of dual energy CT (DECT) after aerosol inhalation of iodinated contrast medium for the evaluation of ventilation function in rabbits with airway obstruction. MATERIALS AND METHODS The study was approved by our institutional animal experimental committee and performed according to animal care guidelines. Airway obstruction was created by injecting gelatin sponge into the right bronchus of 6 New Zealand rabbits. One additional rabbit served as control without airway obstruction. All 7 rabbits then underwent inhalation of aerosol iodinated contrast medium for 5 min, followed by DECT of the lungs from which ventilation CT images were created. CT number and overlay value (calculated iodine enhancement on the ventilation images in hounsfield unit) of the obstructed and non-obstructed lung lobes were measured at 80-kVp, 140-kVp, and weighted average 120-kVp. Immediately after DECT scan, the rabbits were sacrificed, the lungs were removed and detailed pathological examination of the locations and parenchymal changes of the obstructed lung lobes were performed and correlated with DECT ventilation imaging findings. RESULTS Data from one rabbit with airway obstruction were excluded because of post-procedure pneumatothorax. Seventeen normal lung lobes without airway obstruction proven by histopathology had nearly homogeneous ventilation, while 13 abnormal lung lobes had ventilation defects on DECT ventilation images. CT numbers and overlay values of the normal (CT number, -737.77 ± 71.46 HU, -768.84 ± 73.86 HU, -731.86 ± 65.92 HU for 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 46.58 ± 19.49 HU) and abnormal lung lobes (CT number, -183.58 ± 173.37 HU, -124.93 ± 242.23 HU, -166.07 ± 191.57 HU for 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 0.00 ± 0.00 HU) were significantly different at 80-kVp, 140-kVp, and weighted average 120-kVp (P < 0.001 for all). Diffuse hemorrhage, inflammatory cell infiltration, and exudation were observed at histopathology in the obstructed lung lobes. CONCLUSIONS It is feasible to study regional lung ventilation function using DECT after aerosol inhalation of iodinated contrast medium in rabbit. The safety of inhalation of iodine contrast medium is unknown, and has to be investigated further before use of this new method in humans.
Collapse
Affiliation(s)
- Long-Jiang Zhang
- Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, 305 Zhongshan East Road, Xuanwu District, Nanjing, Jiangsu 210002, China
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Park EA, Goo JM, Park SJ, Lee HJ, Lee CH, Park CM, Yoo CG, Kim JH. Chronic Obstructive Pulmonary Disease: Quantitative and Visual Ventilation Pattern Analysis at Xenon Ventilation CT Performed by Using a Dual-Energy Technique. Radiology 2010; 256:985-97. [DOI: 10.1148/radiol.10091502] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
38
|
Sase S, Nakano H, Suzuki H, Honda M. Subtraction lung image for evaluating pulmonary ventilation in xenon-enhanced CT. Med Phys 2010; 37:4464-74. [DOI: 10.1118/1.3464490] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
39
|
Chae EJ, Seo JB, Kim N, Song KS, Shin JH, Kim TH, Lee Y. Collateral Ventilation in a Canine Model with Bronchial Obstruction: Assessment with Xenon-enhanced Dual-Energy CT. Radiology 2010; 255:790-798. [DOI: 10.1148/radiol.10090947] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
|
40
|
Ding K, Bayouth JE, Buatti JM, Christensen GE, Reinhardt JM. 4DCT-based measurement of changes in pulmonary function following a course of radiation therapy. Med Phys 2010; 37:1261-72. [PMID: 20384264 DOI: 10.1118/1.3312210] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Radiation therapy (RT) for lung cancer is commonly limited to subtherapeutic doses due to unintended toxicity to normal lung tissue. Reducing the frequency of occurrence and magnitude of normal lung function loss may benefit from treatment plans that incorporate the regional lung and radiation dose information. In this article, the authors propose a method that quantitatively measures the regional changes in lung tissue function following a course of radiation therapy by using 4DCT and image registration techniques. METHODS 4DCT data sets before and after RT from two subjects are used in this study. Nonlinear 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration to estimate the pulmonary function. The Jacobian of the image registration transformation, indicating local lung expansion or contraction, serves as an index of regional pulmonary function. Approximately 120 annotated vascular bifurcation points are used as landmarks to evaluate registration accuracy. The authors compare regional pulmonary function before and after RT to the planned radiation dose at different locations of the lung. RESULTS In all registration pairs, the average landmark distances after registration are on the order of 1 mm. The pulmonary function change as indicated by the Jacobian change ranges from -0.15 to 0.1 in the contralateral lung and -0.22 to 0.23 in the ipsilateral lung for subject A, and ranges from -0.4 to 0.39 in the contralateral lung and -0.25 to 0.5 in the ipsilateral lung for subject B. Both of the subjects show larger range of the increase in the pulmonary function in the ipsilateral lung than the contralateral lung. For lung tissue regions receiving a radiation dose larger than 24 Gy, a decrease in pulmonary function was observed. For regions receiving a radiation dose smaller than 24 Gy, either an increase or a decrease in pulmonary function was observed. The relationship between the pulmonary function change and the radiation dose varies at different locations. CONCLUSIONS With the use of 4DCT and image registration techniques, the pulmonary function prior to and following a course of radiation therapy can be measured. In the preliminary application of this approach for two subjects, changes in pulmonary function were observed with a weak correlation between the dose and pulmonary function change. In certain sections of the lung, detected locally compromised pulmonary function may have resulted from radiation injury.
Collapse
Affiliation(s)
- Kai Ding
- Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa 52242, USA
| | | | | | | | | |
Collapse
|
41
|
Akhavan Sharif MR, Lam WW, Ouriadov AV, Holdsworth DW, Santyr GE. Comparison of hyperpolarized (3)He MRI rat lung volume measurement with micro-computed tomography. NMR IN BIOMEDICINE 2010; 23:359-367. [PMID: 20099370 DOI: 10.1002/nbm.1470] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2009] [Revised: 08/26/2009] [Accepted: 09/27/2009] [Indexed: 05/28/2023]
Abstract
In this study, the upper-limit volume (gas plus partial tissue volume) as well as absolute volume (gas only) of lungs measured with hyperpolarized (3)He-MR imaging is compared with that determined by micro-computed tomography (CT) under similar ventilation conditions in normal rats. Five Brown Norway rats (210-259 g) were ventilated with O(2), alternately with (3)He, using a computer-controlled ventilator, and 3D density-weighted images of the lungs were acquired during a breath hold after six wash-in breaths of (3)He. The rats were then transferred to a micro-CT scanner, and a similar experimental setup was used to obtain images of the lungs during a breath hold of air with an airway pressure equal to that of the MR imaging breath hold. The upper-limit and absolute volumes obtained from (3)He-MR and micro-CT methods were not significantly different (p > 0.05). The good agreement between the lung volumes measured with the two imaging methods suggests that (3)He-MR imaging can be used for quantitative analysis of lung volume changes in longitudinal studies without the exposure to the ionizing radiation which accompanies micro-CT imaging.
Collapse
|
42
|
Emami K, Kadlecek SJ, Woodburn JM, Zhu J, Yu J, Vahdat V, Pickup S, Ishii M, Rizi RR. Improved technique for measurement of regional fractional ventilation by hyperpolarized 3He MRI. Magn Reson Med 2010; 63:137-50. [PMID: 19877277 DOI: 10.1002/mrm.22186] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Quantitative measurement of regional lung ventilation is of great significance in assessment of lung function in many obstructive and restrictive pulmonary diseases. A new technique for regional measurement of fractional ventilation using hyperpolarized 3He MRI is proposed, addressing the shortcomings of an earlier approach that limited its use to small animals. The new approach allows for the acquisition of similar quantitative maps over a shortened period and requires substantially less 3He gas. This technique is therefore a better platform for implementation in large species, including humans. The measurements using the two approaches were comparable to a great degree, as verified in a healthy rat lung, and are very reproducible. Preliminary validation is performed in a lung phantom system. Volume dependency of measurements was assessed both in vivo and in vitro. A scheme for selecting an optimum flip angle is proposed. In addition, a dead space modeling approach is proposed to yield more accurate measurements of regional fractional ventilation using either method. Finally, sensitivity of the new technique to model parameters, noise, and number of included images were assessed numerically. As a prelude to application in humans, the technique was implemented in a large animal study successfully.
Collapse
Affiliation(s)
- Kiarash Emami
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104-6100, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Remy-Jardin M, Faivre JB, Pontana F, Hachulla AL, Tacelli N, Santangelo T, Remy J. Thoracic Applications of Dual Energy. Radiol Clin North Am 2010; 48:193-205. [DOI: 10.1016/j.rcl.2009.08.013] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
44
|
Quantitative assessment of lung using hyperpolarized magnetic resonance imaging. Ann Am Thorac Soc 2009; 6:431-8. [PMID: 19687215 DOI: 10.1513/pats.200902-008aw] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Improvements in the quantitative assessment of structure, function, and metabolic activity in the lung, combined with improvements in the spatial resolution of those assessments, enhance the diagnosis and evaluation of pulmonary disorders. Radiologic methods are among the most attractive techniques for the comprehensive assessment of the lung, as they allow quantitative assessment of this organ through measurements of a number of structural, functional, and metabolic parameters. Hyperpolarized nuclei magnetic resonance imaging (MRI) has opened up new territories for the quantitative assessment of lung function and structure with an unprecedented spatial resolution and sensitivity. This review article presents a survey of recent developments in the field of pulmonary imaging using hyperpolarized nuclei MRI for quantitative imaging of different aspects of the lung, as well as preclinical applications of these techniques to diagnose and evaluate specific pulmonary diseases. After presenting a brief overview of various hyperpolarization techniques, this survey divides the research activities of the field into four broad areas: lung microstructure, ventilation, oxygenation, and perfusion. Finally, it discusses the challenges currently faced by researchers in this field to translate this rich body of methodology into wider-scale clinical applications.
Collapse
|
45
|
Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury. Anesthesiology 2009; 111:1065-74. [PMID: 19809280 DOI: 10.1097/aln.0b013e3181bc99cf] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Studies using transthoracic thermodilution have demonstrated increased extravascular lung water (EVLW) measurements attributed to progression of edema and flooding during sepsis and acute lung injury. The authors hypothesized that redistribution of pulmonary blood flow can cause increased apparent EVLW secondary to increased perfusion of thermally silent tissue, not increased lung edema. METHODS Anesthetized, mechanically ventilated canines were instrumented with PiCCO (Pulsion Medical, Munich, Germany) catheters and underwent lung injury by repetitive saline lavage. Hemodynamic and respiratory physiologic data were recorded. After stabilized lung injury, endotoxin was administered to inactivate hypoxic pulmonary vasoconstriction. Computed tomographic imaging was performed to quantify in vivo lung volume, total tissue (fluid) and air content, and regional distribution of blood flow. RESULTS Lavage injury caused an increase in airway pressures and decreased arterial oxygen content with minimal hemodynamic effects. EVLW and shunt fraction increased after injury and then markedly after endotoxin administration. Computed tomographic measurements quantified an endotoxin-induced increase in pulmonary blood flow to poorly aerated regions with no change in total lung tissue volume. CONCLUSIONS The abrupt increase in EVLW and shunt fraction after endotoxin administration is consistent with inactivation of hypoxic pulmonary vasoconstriction and increased perfusion to already flooded lung regions that were previously thermally silent. Computed tomographic studies further demonstrate in vivo alterations in regional blood flow (but not lung water) and account for these alterations in shunt fraction and EVLW.
Collapse
|
46
|
Determinants of regional ventilation and blood flow in the lung. Intensive Care Med 2009; 35:1833-42. [DOI: 10.1007/s00134-009-1649-3] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2009] [Accepted: 08/12/2009] [Indexed: 11/26/2022]
|
47
|
Volumetric xenon-CT imaging of conventional and high-frequency oscillatory ventilation. Acad Radiol 2009; 16:718-25. [PMID: 19268611 DOI: 10.1016/j.acra.2008.12.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2008] [Revised: 12/01/2008] [Accepted: 12/05/2008] [Indexed: 11/23/2022]
Abstract
RATIONALE AND OBJECTIVES For mechanical ventilation of patients with pulmonary injuries, it has been proposed that high-frequency oscillatory ventilation (HFOV) offers advantages over conventional ventilation (CV); however, these advantages have been difficult to quantify. We used volumetric, dynamic imaging of Xenon (Xe) washout of the canine lung during both HFOV and CV to compare regional ventilation in the two modalities. MATERIALS AND METHODS Three anesthetized, mechanically ventilated animals were studied, each at three different ventilator settings. Imaging was performed on an experimental Toshiba 256-slice scanner at 80 kV, 250 mAs, and 0.5-second scans, yielding 12.8 cm of Z-axis coverage. Repeated images were acquired at increasing intervals between 1 and 10 seconds for 90 seconds during HFOV and using retrospective respiratory gating to end-expiration for 60 seconds during CV. Image series were analyzed to quantify regional specific ventilation (sV ) from the regional density washout time constants. RESULTS High-quality, high-resolution regional ventilation maps were obtained during both CV and HFOV. Overall ventilation decreased at smaller tidal volume, as expected. Regional sV was more uniform during HFOV compared to CV, but the underlying distribution of lung aeration was similar. CONCLUSIONS High-resolution volumetric ventilation maps of the lung may be obtained with the 256-slice multidetector computed tomographic scanner. There is a marked difference in the distribution of regional ventilation between CV and HFOV, with a significant gravitational ventilation gradient in CV that was not present during HFOV. This technique may be useful in exploring the mechanisms by which HFOV improves gas exchange.
Collapse
|
48
|
Bayat S, Porra L, Suhonen H, Suortti P, Sovijärvi ARA. Paradoxical conducting airway responses and heterogeneous regional ventilation after histamine inhalation in rabbit studied by synchrotron radiation CT. J Appl Physiol (1985) 2009; 106:1949-58. [PMID: 19359611 DOI: 10.1152/japplphysiol.90550.2008] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
We studied both central conducting airway response and changes in the distribution of regional ventilation induced by inhaled histamine in healthy anesthetized and mechanically ventilated rabbit using a novel xenon-enhanced synchrotron radiation computed tomography (CT) imaging technique, K-edge subtraction imaging (KES). Images of specific ventilation were obtained using serial KES during xenon washin, in three axial lung slices, at baseline and twice after inhalation of histamine aerosol (50 or 125 mg/ml) in two groups of animals (n = 6 each). Histamine inhalation caused large clustered areas of poor ventilation, characterized by a drop in average specific ventilation (sV(m)), but an increase in sV(m) in the remaining lung zones indicating ventilation redistribution. Ventilation heterogeneity, estimated as coefficient of variation (CV) of sV(m) significantly increased following histamine inhalation. The area of ventilation defects and CV were significantly larger with the higher histamine dose. In conducting airways, histamine inhalation caused a heterogeneous airway response combining narrowing and dilatation in individual airways of different generations, with the probability for constriction increasing peripherally. This finding provides further in vivo evidence that airway reactivity in response to inhaled histamine is complex and that airway response may vary substantially with location within the bronchial tree.
Collapse
Affiliation(s)
- Sam Bayat
- Centre Hospitalier Universitaire d'Amiens, Cardiologie et Pneumo-Allergologie Pédiatriques, 80054 Amiens Cedex 1, France.
| | | | | | | | | |
Collapse
|
49
|
Tzeng YS, Lutchen K, Albert M. The difference in ventilation heterogeneity between asthmatic and healthy subjects quantified using hyperpolarized 3He MRI. J Appl Physiol (1985) 2008; 106:813-22. [PMID: 19023025 DOI: 10.1152/japplphysiol.01133.2007] [Citation(s) in RCA: 130] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
In this pilot study, algorithms for quantitatively evaluating the distribution and heterogeneity of human ventilation imaged with hyperpolarized (HP) (3)He MRI were developed for the goal of examining structure-function relationships within the asthmatic lung. Ten asthmatic and six healthy human subjects were imaged with HP (3)He MRI before bronchial challenge (pre-MCh), after bronchial challenge (post-MCh), and after a series of deep inspirations (post-DI) following challenge. The acquired images were rigidly coregistered. Local voxel fractional ventilation was computed by setting the sum of the pixel intensity within the lung region in each image to 1 liter of inhaled (3)He mixture. Local ventilation heterogeneity was quantified by computing regional signal coefficient of variation. Voxel fractional ventilation histograms and overall heterogeneity scores were then calculated. Asthmatic subjects had a higher ventilation heterogeneity to begin with (P = 0.025). A methacholine challenge elevated ventilation heterogeneity for all subjects (difference: P = 0.08). After a DI postchallenge, this heterogeneity reversed substantially toward the baseline state for healthy subjects but only minimally in asthmatic subjects. This difference was significant in absolute quantity (difference: P = 0.007) as well as relative to the initial increase (difference: P = 0.03). These findings suggest that constriction heterogeneity is not a characteristic unique to asthmatic airway trees but rather a behavior intrinsic to all airway trees when provoked. Once ventilation heterogeneity is established, it is the lack of reversal following DIs that distinguishes asthmatics from non-asthmatics.
Collapse
Affiliation(s)
- Yang-Sheng Tzeng
- Department of Radiology, Brigham & Women's Hospital, Boston, Massachusetts 01655, USA
| | | | | |
Collapse
|
50
|
Total and regional lung volume changes during high-frequency oscillatory ventilation (HFOV) of the normal lung. Respir Physiol Neurobiol 2008; 165:54-60. [PMID: 18996228 DOI: 10.1016/j.resp.2008.10.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2008] [Revised: 09/15/2008] [Accepted: 10/06/2008] [Indexed: 11/24/2022]
Abstract
The effect of high-frequency oscillatory ventilation (HFOV) settings on the distribution of lung volume (V(L)) with changes in mean airway pressure (Paw), frequency (f(R)) and tidal volume (V(T)) remains controversial. We used computer tomographic (CT) imaging to quantify the distribution of V(L) during HFOV compared to static continuous positive airway pressure (CPAP). In anesthetized, supine canines, CT imaging of the entire lung was performed during CPAP and HFOV at Paw of 5, 12.5 and 20 cm H(2)O, f(R)=5, 10, 15 Hz. We found small, statistically significant decreases compared with CPAP in total and regional V(L) during HFOV that were greatest at lower f(R) and Paw. Apex and base sub-volumes underwent changes comparable to the lung overall. Increases in f(R) were accompanied by increases in Pa(O)(2). These finding provide additional insight into the impact of HFOV settings on the distribution of V(L) and suggest that there is low risk of occult regional over-distention during HFOV in normal lungs.
Collapse
|