1
|
Liang S, Zhou G, Hu W. Research Progress of Heavy Ion Radiotherapy for Non-Small-Cell Lung Cancer. Int J Mol Sci 2022; 23:2316. [PMID: 35216430 PMCID: PMC8876478 DOI: 10.3390/ijms23042316] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/10/2022] [Accepted: 02/18/2022] [Indexed: 02/05/2023] Open
Abstract
Non-small-cell lung cancer (NSCLC) has a high incidence and poses a serious threat to human health. However, the treatment outcomes of concurrent chemoradiotherapy for non-small-cell lung cancer are still unsatisfactory, especially for high grade lesions. As a new cancer treatment, heavy ion radiotherapy has shown promising efficacy and safety in the treatment of non-small-cell lung cancer. This article discusses the clinical progress of heavy ion radiotherapy in the treatment of non-small-cell lung cancer mainly from the different cancer stages, the different doses of heavy ion beams, and the patient's individual factors, and explores the deficiency of heavy ion radiotherapy in the treatment of non-small-cell lung cancer and the directions of future research, in order to provide reference for the wider and better application of heavy ion radiotherapy in the future.
Collapse
Affiliation(s)
| | - Guangming Zhou
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, China;
| | - Wentao Hu
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, China;
| |
Collapse
|
2
|
Riva G, Imparato S, Savietto G, Pecorilla M, Iannalfi A, Barcellini A, Ronchi S, Fiore MR, Paganelli C, Buizza G, Ciocca M, Baroni G, Preda L, Orlandi E. Potential role of functional imaging in predicting outcome for patients treated with carbon ion therapy: a review. Br J Radiol 2021; 94:20210524. [PMID: 34520670 DOI: 10.1259/bjr.20210524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE Carbon ion radiation therapy (CIRT) is an emerging radiation technique with advantageous physical and radiobiologic properties compared to conventional radiotherapy (RT) providing better response in case of radioresistant and hypoxic tumors. Our aim is to critically review if functional imaging techniques could play a role in predicting outcome of CIRT-treated tumors, as already proven for conventional RT. METHODS 14 studies, concerning Magnetic resonance imaging (MRI) and Positron Emission Tomography (PET), were selected after a comprehensive search on multiple electronic databases from January 2000 to March 2020. RESULTS MRI studies (n = 5) focused on diffusion-weighted MRI and, even though quantitative parameters were the same in all studies (apparent diffusion coefficient, ADC), results were not univocal, probably due to different imaging acquisition protocols and tumoral histology. For PET studies (n = 9), different tracers were used such as [18F]FDG and other uncommon tracers ([11C]MET, [18F]FLT), with a relevant heterogeneity regarding parameters used for outcome assessment. CONCLUSION No conclusion can be drawn on the predictive value of functional imaging in CIRT-treated tumors. A standardization of image acquisition, multi-institutional large trials and external validations are needed in order to establish the prognostic value of functional imaging in CIRT and to guide clinical practice. ADVANCES IN KNOWLEDGE Emerging studies focused on functional imaging's role in predicting CIRT outcome. Due to the heterogeneity of images acquisition and studies, results are conflicting and prospective large studies with imaging standardized protocol are needed.
Collapse
Affiliation(s)
- Giulia Riva
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Sara Imparato
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Giovanni Savietto
- Unit of Radiology, Department of Clinical, Surgical, Diagnostic, and Pediatric Sciences, University of Pavia, Pavia, Italy
| | - Mattia Pecorilla
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Alberto Iannalfi
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Amelia Barcellini
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Sara Ronchi
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Maria Rosaria Fiore
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milano, Italy
| | - Giulia Buizza
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milano, Italy
| | - Mario Ciocca
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milano, Italy
| | - Lorenzo Preda
- Unit of Radiology, Department of Clinical, Surgical, Diagnostic, and Pediatric Sciences, University of Pavia, Pavia, Italy.,Department of Radiology, I.R.C.C.S. Policlinico San Matteo Foundation, Pavia, Italy
| | - Ester Orlandi
- Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| |
Collapse
|
3
|
Shirai K, Kawashima M, Saitoh JI, Abe T, Fukata K, Shigeta Y, Irie D, Shiba S, Okano N, Ohno T, Nakano T. Clinical outcomes using carbon-ion radiotherapy and dose-volume histogram comparison between carbon-ion radiotherapy and photon therapy for T2b-4N0M0 non-small cell lung cancer-A pilot study. PLoS One 2017; 12:e0175589. [PMID: 28399182 PMCID: PMC5388495 DOI: 10.1371/journal.pone.0175589] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2016] [Accepted: 03/28/2017] [Indexed: 12/25/2022] Open
Abstract
The safety and efficacy of carbon-ion radiotherapy for advanced non-small cell lung cancer have not been established. We evaluated the clinical outcomes and dose-volume histogram parameters of carbon-ion radiotherapy compared with photon therapy in T2b–4N0M0 non-small cell lung cancer. Twenty-three patients were treated with carbon-ion radiotherapy between May 2011 and December 2015. Seven, 14, and 2 patients had T2b, T3, and T4, respectively. The median age was 78 (range, 53−91) years, with 22 male patients. There were 12 adenocarcinomas, 8 squamous cell carcinomas, 1 non-small cell lung carcinoma, and 2 clinically diagnosed lung cancers. Eleven patients were operable, and 12 patients were inoperable. Most patients (91%) were treated with carbon-ion radiotherapy of 60.0 Gy relative biological effectiveness (RBE) in 4 fractions or 64.0 Gy (RBE) in 16 fractions. Local control and overall survival rates were calculated. Dose-volume histogram parameters of normal lung and tumor coverages were compared between carbon-ion radiotherapy and photon therapies, including three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT). The median follow-up of surviving patients was 25 months. Three patients experienced local recurrence, and the 2-year local control rate was 81%. During follow-up, 5 patients died of lung cancer, and 1 died of intercurrent disease. The 2-year overall survival rate was 70%. Operable patients had a better overall survival rate compared with inoperable patients (100% vs. 43%; P = 0.04). There was no grade ≥2 radiation pneumonitis. In dose-volume histogram analysis, carbon-ion radiotherapy had a significantly lower dose to normal lung and greater tumor coverage compared with photon therapies. Carbon-ion radiotherapy was effectively and safely performed for T2b–4N0M0 non-small cell lung cancer, and the dose distribution was superior compared with those for photon therapies. A Japanese multi-institutional study is ongoing to prospectively evaluate these patients and establish the use of carbon-ion radiotherapy.
Collapse
Affiliation(s)
- Katsuyuki Shirai
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
- * E-mail:
| | | | - Jun-ichi Saitoh
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| | - Takanori Abe
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| | - Kyohei Fukata
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| | - Yuka Shigeta
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| | - Daisuke Irie
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| | - Shintaro Shiba
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| | - Naoko Okano
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| | - Tatsuya Ohno
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| | - Takashi Nakano
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
| |
Collapse
|
4
|
Shirai K, Abe T, Saitoh JI, Mizukami T, Irie D, Takakusagi Y, Shiba S, Okano N, Ebara T, Ohno T, Nakano T. Maximum standardized uptake value on FDG-PET predicts survival in stage I non-small cell lung cancer following carbon ion radiotherapy. Oncol Lett 2017; 13:4420-4426. [PMID: 28588712 DOI: 10.3892/ol.2017.5952] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2015] [Accepted: 02/17/2017] [Indexed: 12/29/2022] Open
Abstract
The present study (University Hospital Medical Information Network study no. UMIN000003797) aimed to evaluate whether the maximum standardized uptake value (SUVmax) of pretreatment 18F-fluorodeoxyglucose-positron emission tomography (FDG-PET) is prognostic factor for stage I non-small cell lung cancer (NSCLC) treated with carbon ion radiotherapy (C-ion RT). Patients treated between June 2010 and June 2013 at Gunma University Heavy Ion Medical Center (Maebashi, Japan) on a prospective protocol were included in the present study. Patients with T1a-b and T2a NSCLC were treated with C-ion RT at a dose of 52.8 Gy [relative biological effectiveness (RBE)] and 60.0 Gy (RBE), respectively, in four fractions. Prior to treatment, all patients underwent FDG-PET, in which the SUVmax of primary tumors was evaluated. Local control, progression-free survival (PFS), and overall survival (OS) were calculated. A total of 45 patients were analyzed and the median follow-up period was 28.9 months. The 2-year local control, PFS and OS rates for all patients were 93, 78 and 89%, respectively. The mean SUVmax of primary tumors was 5.5, and patients were divided into higher (≥5.5) and lower (<5.5) SUVmax groups. The 2-year PFS rates were 61 and 89% for the higher and lower SUVmax groups, respectively (P=0.01), and the 2-year OS rates for the higher and lower SUVmax groups were 76 and 96%, respectively (P=0.01). The higher SUVmax group exhibited a significantly worse PFS and OS compared with the lower SUVmax group; however, the SUVmax was not associated with the local control rate. In total, 2 patients (4%) experienced grade 2 or 3 radiation pneumonitis, with their symptoms improved through conservative treatment. No patients experienced any grade 4 or 5 toxicities. The results of the present study indicate that pretreatment SUVmax is a prognostic indicator for outcomes in patients with stage I NSCLC treated with C-ion RT.
Collapse
Affiliation(s)
- Katsuyuki Shirai
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Takanori Abe
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Jun-Ichi Saitoh
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Tatsuji Mizukami
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Daisuke Irie
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Yosuke Takakusagi
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Shintaro Shiba
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Naoko Okano
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Takeshi Ebara
- Department of Radiation Oncology, Gunma Prefectural Cancer Center, Ota, Gunma 373-8550, Japan
| | - Tatsuya Ohno
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| | - Takashi Nakano
- Gunma University Heavy Ion Medical Center, Maebashi, Gunma 371-8511, Japan
| |
Collapse
|
5
|
Berberoğlu K. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer. Mol Imaging Radionucl Ther 2016; 25:50-62. [PMID: 27277321 PMCID: PMC5096621 DOI: 10.4274/mirt.19870] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Radiotherapy (RT) plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT) during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT) has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases inter-user variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.
Collapse
Affiliation(s)
- Kezban Berberoğlu
- Anadolu Medical Center, Clinic of Nuclear Medicine, İstanbul, Turkey, Phone: +90 532 584 62 56 E-mail:
| |
Collapse
|
6
|
Vaidya PJ, Kate AH, Yasufuku K, Chhajed PN. Endobronchial ultrasound-guided transbronchial needle aspiration in lung cancer diagnosis and staging. Expert Rev Respir Med 2014; 9:45-53. [PMID: 25496515 DOI: 10.1586/17476348.2015.992784] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Lung cancer is one of the most prevalent types of cancer in the world. A complete diagnosis of lung cancer involves tissue acquisition for pathological subtype, molecular diagnosis and accurate staging of the disease to guide appropriate therapy. Real-time endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is minimally invasive and relatively safe procedure, which can be done on an outpatient basis under moderate sedation. EBUS-TBNA has been shown to be a safe modality to obtain tissue for diagnosis, staging and molecular profiling in lung cancer. EBUS-TBNA stands out in comparison with other modalities for tissue acquisition in lung cancer. EBUS-TBNA performed with the patient under moderate sedation yields sufficient tissue for sequential molecular analysis in most patients. In this review, we describe the role of EBUS-TBNA in various aspects of diagnosis and staging of lung cancer in the present era along with its future aspects.
Collapse
Affiliation(s)
- Preyas J Vaidya
- Institute of Pulmonology, Medical Research and Development, Mumbai, India
| | | | | | | |
Collapse
|
7
|
Guo Y, Feng Y, Sun J, Zhang N, Lin W, Sa Y, Wang P. Automatic lung tumor segmentation on PET/CT images using fuzzy Markov random field model. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2014; 2014:401201. [PMID: 24987451 PMCID: PMC4058834 DOI: 10.1155/2014/401201] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Accepted: 05/12/2014] [Indexed: 11/18/2022]
Abstract
The combination of positron emission tomography (PET) and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF) model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC) patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice's similarity coefficient (DSC) was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum.
Collapse
Affiliation(s)
- Yu Guo
- Tianjin Key Lab of BME Measurement, Tianjin University, Tianjin 300072, China
| | - Yuanming Feng
- Tianjin Key Lab of BME Measurement, Tianjin University, Tianjin 300072, China
- Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin 300060, China
| | - Jian Sun
- Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin 300060, China
| | - Ning Zhang
- Tianjin Key Lab of BME Measurement, Tianjin University, Tianjin 300072, China
| | - Wang Lin
- Tianjin Key Lab of BME Measurement, Tianjin University, Tianjin 300072, China
| | - Yu Sa
- Tianjin Key Lab of BME Measurement, Tianjin University, Tianjin 300072, China
| | - Ping Wang
- Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, Tianjin 300060, China
| |
Collapse
|
8
|
Oncological Applications of Positron Emission Tomography for Evaluation of the Thorax. J Thorac Imaging 2013; 28:11-24. [DOI: 10.1097/rti.0b013e318279449b] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|