1
|
GÜN N, KARABOCE B, YURDALAN U. INVESTIGATION OF THERAPEUTIC ULTRASOUND DOSE ON MUSCLE PHANTOM: AN EXPERIMENTAL STUDY. CLINICAL AND EXPERIMENTAL HEALTH SCIENCES 2021. [DOI: 10.33808/clinexphealthsci.950896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
2
|
Low-Intensity Pulsed Ultrasound Effect on MIO-M1 Cell Viability: Setup Validation and Standing Waves Analysis. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app11010271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Low-intensity pulsed ultrasound (LIPUS) has been proposed for novel therapies still under study, where similar parameters and protocols have been used for producing opposite effects that range from increasing cell viability to provoking cell death. Those divergent outcomes make the generalization of expected effects difficult for cell models not yet studied. This paper presents the effect of LIPUS on the viability of the MIO-M1 cell line for two well-established setups and different protocols; the acoustic intensities, duty factors, and treatment duration were varied. Measurements and models for acoustic and thermal analysis are included for proposing a solution to improve the reproducibility of this kind of experiments. Results indicate that MIO-M1 viability is less affected for the cells treated through a dish that is partially immersed in water; in these conditions, the cells neither show detrimental nor proliferative effects at intensities lower than 0.4 W/cm2 at 20% duty factor. However, cell viability was reduced when LIPUS was followed by cell subculturing. Treating the cells through a gel, with the culture dish placed on the transducer, increases cell mortality by the production of standing waves and mixed vibration-acoustical effects. Using the water-based setup with a 1° dish inclination reduces the effects of standing waves.
Collapse
|
3
|
Nonuniform Bessel-Based Radiation Distributions on A Spherically Curved Boundary for Modeling the Acoustic Field of Focused Ultrasound Transducers. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9050911] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Therapeutic focused ultrasound is a technique that can be used with different intensities depending on the application. For instance, low intensities are required in nonthermal therapies, such as drug delivering, gene therapy, etc.; high intensity ultrasound is used for either thermal therapy or instantaneous tissue destruction, for example, in oncologic therapy with hyperthermia and tumor ablation. When an adequate therapy planning is desired, the acoustic field models of curve radiators should be improved in terms of simplicity and congruence at the prefocal zone. Traditional ideal models using uniform vibration distributions usually do not produce adequate results for clamped unbacked curved radiators. In this paper, it is proposed the use of a Bessel-based nonuniform radiation distribution at the surface of a curved radiator to model the field produced by real focused transducers. This proposal is based on the observed complex vibration of curved transducers modified by Lamb waves, which have a non-negligible effect in the acoustic field. The use of Bessel-based functions to approximate the measured vibration instead of using plain measurements simplifies the rationale and expands the applicability of this modeling approach, for example, when the determination of the effects of ultrasound in tissues is required.
Collapse
|