1
|
Zhang L, Zuo J, Wang K, Jiang T, Gu S, Xu L, Zhang Y. An advanced robotic system incorporating haptic feedback for precision cardiac ablation procedures. Sci Rep 2025; 15:6839. [PMID: 40000834 PMCID: PMC11862161 DOI: 10.1038/s41598-025-91342-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2024] [Accepted: 02/19/2025] [Indexed: 02/27/2025] Open
Abstract
This study introduces an innovative master-slave cardiac ablation catheter robot system that employs magnetorheological fluids. The system incorporates magnetorheological fluid to enable collision detection through haptic feedback, thereby enhancing the operator's situational awareness. A modular clamping and propulsion mechanism has been engineered for the ablation catheter, facilitating omnidirectional operation and force feedback within the cardiac cavity. To evaluate the proposed system, an in vitro experiment was performed. Results from the experiment indicate that the system demonstrates high motion transmission accuracy. Furthermore, the system effectively alerts operators to potential collisions, enabling swift catheter position adjustments, minimizing the risk of vascular perforation, and ultimately enhancing the overall safety and efficiency of the procedure.
Collapse
Affiliation(s)
- Linshuai Zhang
- School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, 611137, China
- School of Automation, Chengdu University of Information Technology, Chengdu, 610225, China
- International Joint Research Center of Robotics and Intelligence System of Sichuan Province, Chengdu, Sichuan, China
| | - Jinshan Zuo
- School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, 611137, China
| | - Ke Wang
- School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, 611137, China
| | - Tao Jiang
- School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, 611137, China.
| | - Shuoxin Gu
- School of Automation, Chengdu University of Information Technology, Chengdu, 610225, China.
| | - Lin Xu
- School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, 611137, China
| | - Yujie Zhang
- School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, 611137, China
| |
Collapse
|
2
|
Pescio M, Kundrat D, Dagnino G. Endovascular robotics: technical advances and future directions. MINIM INVASIV THER 2025:1-14. [PMID: 39835841 DOI: 10.1080/13645706.2025.2454237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 12/13/2024] [Indexed: 01/22/2025]
Abstract
Endovascular interventions excel in treating cardiovascular diseases in a minimally invasive manner, showing improved outcomes over open techniques. However, challenges related to precise navigation - still relying on 2D fluoroscopy - persist. This review examines the role of robotics, highlighting commercial and research platforms, while exploring emerging trends like MRI compatibility, enhanced navigation, and autonomy. MRI-compatible systems offer radiation-free 3D imaging. Human-robot interaction evolves with task-specific interfaces, while autonomy ranges from partial to full, aiding clinical operators. Challenges include complexity and cost, emphasizing compatibility and navigation advancements. Integrating MRI-compatible robots, refining human-robot interaction, and enhancing autonomy promise advancements in endovascular surgery, fueled by AI and innovative imaging.
Collapse
Affiliation(s)
- Matteo Pescio
- Bioengineering, Polytechnic University of Turin, Turin, Italy
- University of Turin, Turin, Italy
| | - Dennis Kundrat
- Individualized Therapy, Fraunhofer Research Institution for Individualized and Cell-Based Medical Engineering (IMTE), Lübeck, Germany
| | - Giulio Dagnino
- University of Turin, Turin, Italy
- Robotics and Mechatronics, University of Twente, Enschede, The Netherlands
| |
Collapse
|
3
|
Najafi G, Kreiser K, Abdelaziz MEMK, Hamady MS. Current State of Robotics in Interventional Radiology. Cardiovasc Intervent Radiol 2023; 46:549-561. [PMID: 37002481 PMCID: PMC10156773 DOI: 10.1007/s00270-023-03421-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 03/11/2023] [Indexed: 05/04/2023]
Abstract
As a relatively new specialty with a minimally invasive nature, the field of interventional radiology is rapidly growing. Although the application of robotic systems in this field shows great promise, such as with increased precision, accuracy, and safety, as well as reduced radiation dose and potential for teleoperated procedures, the progression of these technologies has been slow. This is partly due to the complex equipment with complicated setup procedures, the disruption to theatre flow, the high costs, as well as some device limitations, such as lack of haptic feedback. To further assess these robotic technologies, more evidence of their performance and cost-effectiveness is needed before their widespread adoption within the field. In this review, we summarise the current progress of robotic systems that have been investigated for use in vascular and non-vascular interventions.
Collapse
Affiliation(s)
- Ghazal Najafi
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, SW7 2AZ, UK.
| | - Kornelia Kreiser
- Department of Neuroradiology, Rehabilitations - und Universitätskliniken Ulm, 89081, Ulm, Germany
| | - Mohamed E M K Abdelaziz
- The Hamlyn Centre, Imperial College London, London, SW7 2AZ, UK
- Department of Electrical and Electronic Engineering, Faculty of Engineering, Imperial College London, London, SW7 2AZ, UK
| | - Mohamad S Hamady
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, SW7 2AZ, UK
- The Hamlyn Centre, Imperial College London, London, SW7 2AZ, UK
| |
Collapse
|
4
|
Li Z, Manzionna E, Monizzi G, Mastrangelo A, Mancini ME, Andreini D, Dankelman J, De Momi E. Position-based dynamics simulator of vessel deformations for path planning in robotic endovascular catheterization. Med Eng Phys 2022; 110:103920. [PMID: 36564143 DOI: 10.1016/j.medengphy.2022.103920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 09/14/2022] [Accepted: 11/03/2022] [Indexed: 11/08/2022]
Abstract
A major challenge during autonomous navigation in endovascular interventions is the complexity of operating in a deformable but constrained workspace with an instrument. Simulation of deformations for it can provide a cost-effective training platform for path planning. Aim of this study is to develop a realistic, auto-adaptive, and visually plausible simulator to predict vessels' global deformation induced by the robotic catheter's contact and cyclic heartbeat motion. Based on a Position-based Dynamics (PBD) approach for vessel modeling, Particle Swarm Optimization (PSO) algorithm is employed for an auto-adaptive calibration of PBD deformation parameters and of the vessels movement due to a heartbeat. In-vitro experiments were conducted and compared with in-silico results. The end-user evaluation results were reported through quantitative performance metrics and a 5-Point Likert Scale questionnaire. Compared with literature, this simulator has an error of 0.23±0.13% for deformation and 0.30±0.85mm for the aortic root displacement. In-vitro experiments show an error of 1.35±1.38mm for deformation prediction. The end-user evaluation results show that novices are more accustomed to using joystick controllers, and cardiologists are more satisfied with the visual authenticity. The real-time and accurate performance of the simulator make this framework suitable for creating a dynamic environment for autonomous navigation of robotic catheters.
Collapse
Affiliation(s)
- Zhen Li
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan 20133, Italy; Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, CD Delft 2628, Netherlands.
| | - Enrico Manzionna
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan 20133, Italy
| | | | | | | | - Daniele Andreini
- Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| | - Jenny Dankelman
- Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, CD Delft 2628, Netherlands
| | - Elena De Momi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan 20133, Italy
| |
Collapse
|
5
|
Innovation, disruptive Technologien und Transformation in der Gefäßchirurgie. GEFÄSSCHIRURGIE 2022. [DOI: 10.1007/s00772-022-00943-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
6
|
Zhao Y, Mei Z, Luo X, Mao J, Zhao Q, Liu G, Wu D. Remote vascular interventional surgery robotics: a literature review. Quant Imaging Med Surg 2022; 12:2552-2574. [PMID: 35371939 PMCID: PMC8923856 DOI: 10.21037/qims-21-792] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 12/22/2021] [Indexed: 07/25/2023]
Abstract
Vascular interventional doctors are exposed to radiation hazards during surgery and endure high work intensity. Remote vascular interventional surgery robotics is a hot research field, in which researchers aim to not only protect the health of interventional doctors, but to also improve surgical accuracy and efficiency. However, the current vascular interventional robots have numerous shortcomings, such as poor haptic feedback, few compatible surgeries and instruments, and cumbersome maintenance and operational procedures. Nevertheless, vascular interventional surgery combined with robotics provides more cutting-edge directions, such as Internet remote surgery combined with 5G network technology and the application of artificial intelligence in surgical procedures. To summarize the developmental status and key technical points of intravascular interventional surgical robotics research, we performed a systematic literature search to retrieve original articles related to remote vascular interventional surgery robotics published up to December 2020. This review, which includes 113 articles published in English, introduces the mechanical and structural characteristics of various aspects of vascular interventional surgical robotics, discusses the current key features of vascular interventional surgical robotics in force sensing, haptic feedback, and control methods, and summarizes current frontiers in autonomous surgery, long-distance robotic telesurgery, and magnetic resonance imaging (MRI)-compatible structures. On the basis of summarizing the current research status of remote vascular interventional surgery robotics, we aim to propose a variety of prospects for future robotic systems.
Collapse
Affiliation(s)
- Yang Zhao
- Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen, China
| | - Ziyang Mei
- Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen, China
| | - Xiaoxiao Luo
- Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen, China
| | - Jingsong Mao
- Department of Radiology, Xiang’an Hospital of Xiamen University, Xiamen, China
| | - Qingliang Zhao
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen, China
| | - Gang Liu
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen, China
| | - Dezhi Wu
- Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen, China
| |
Collapse
|
7
|
Phelan MF, Tiryaki ME, Lazovic J, Gilbert H, Sitti M. Heat-Mitigated Design and Lorentz Force-Based Steering of an MRI-Driven Microcatheter toward Minimally Invasive Surgery. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2105352. [PMID: 35112810 PMCID: PMC8981448 DOI: 10.1002/advs.202105352] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 01/08/2022] [Indexed: 05/11/2023]
Abstract
Catheters integrated with microcoils for electromagnetic steering under the high, uniform magnetic field within magnetic resonance (MR) scanners (3-7 Tesla) have enabled an alternative approach for active catheter operations. Achieving larger ranges of tip motion for Lorentz force-based steering have previously been dependent on using high power coupled with active cooling, bulkier catheter designs, or introducing additional microcoil sets along the catheter. This work proposes an alternative approach using a heat-mitigated design and actuation strategy for a magnetic resonance imaging (MRI)-driven microcatheter. A quad-configuration microcoil (QCM) design is introduced, allowing miniaturization of existing MRI-driven, Lorentz force-based catheters down to 1-mm diameters with minimal power consumption (0.44 W). Heating concerns are experimentally validated using noninvasive MRI thermometry. The Cosserat model is implemented within an MR scanner and results demonstrate a desired tip range up to 110° with 4° error. The QCM is used to validate the proposed model and power-optimized steering algorithm using an MRI-compatible neurovascular phantom and ex vivo kidney tissue. The power-optimized tip orientation controller conserves as much as 25% power regardless of the catheter's initial orientation. These results demonstrate the implementation of an MRI-driven, electromagnetic catheter steering platform for minimally invasive surgical applications without the need for camera feedback or manual advancement via guidewires. The incorporation of such system in clinics using the proposed design and actuation strategy can further improve the safety and reliability of future MRI-driven active catheter operations.
Collapse
Affiliation(s)
- Martin Francis Phelan
- Physical Intelligence DepartmentMax Planck Institute for Intelligent Systems70569StuttgartGermany
- Department of Mechanical EngineeringCarnegie Mellon UniversityPittsburghPA15213USA
| | - Mehmet Efe Tiryaki
- Physical Intelligence DepartmentMax Planck Institute for Intelligent Systems70569StuttgartGermany
- Institute for Biomedical EngineeringETH ZurichZurich8092Switzerland
| | - Jelena Lazovic
- Physical Intelligence DepartmentMax Planck Institute for Intelligent Systems70569StuttgartGermany
| | - Hunter Gilbert
- Department of Mechanical and Industrial EngineeringLouisiana State UniversityBaton RougeLA70803USA
| | - Metin Sitti
- Physical Intelligence DepartmentMax Planck Institute for Intelligent Systems70569StuttgartGermany
- Department of Mechanical EngineeringCarnegie Mellon UniversityPittsburghPA15213USA
- Institute for Biomedical EngineeringETH ZurichZurich8092Switzerland
- College of Engineering and School of MedicineKoç UniversityIstanbul34450Turkey
| |
Collapse
|
8
|
Cruddas L, Martin G, Riga C. Robotic endovascular surgery: current and future practice. Semin Vasc Surg 2021; 34:233-240. [PMID: 34911629 DOI: 10.1053/j.semvascsurg.2021.10.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 10/10/2021] [Accepted: 10/13/2021] [Indexed: 11/11/2022]
Abstract
Minimally invasive techniques have been at the forefront of surgical progress, and the evolution of endovascular robotic technologies has seen a paradigm shift in the focus of future innovation. Endovascular robotic technology may help overcome many of the challenges associated with traditional endovascular techniques by enabling greater control, stability, and precision of target navigation and treatment, while simultaneously reducing operator learning curves and improving safety. Several robotic systems have been developed to perform a broad range of endovascular procedures, but none have been used at scale or widely in routine practice, and the evidence for their safety, effectiveness, and efficiency remains limited. High cost and device complexity, lack of haptic feedback, and limited integration and interoperability with existing equipment and devices are the principal technology, cost, and sustainability barriers to the scalability and widespread adoption in day-to-day practice. In order to fully realize its potential, future robotic innovation must ensure compatibility with a range of off-the-shelf equipment that can be tracked and exchanged quickly during a procedure and come together with developments in navigation, tracking, and imaging. Reducing cost and complexity and supporting sustainability of the technology is key. In parallel, new technologies must be evaluated by clear and transparent standardized outcomes and be accompanied by robust clinical training. Key to the successful future development and dissemination of robotic technology is open collaboration among industry, clinicians, and patients in order to fully understand and address current challenges and enable the technology to realize its full potential.
Collapse
Affiliation(s)
- Lucinda Cruddas
- Imperial Vascular Unit, Imperial College Healthcare NHS Trust, London, UK
| | - Guy Martin
- Imperial Vascular Unit, Imperial College Healthcare NHS Trust, London, UK; Department of Surgery and Cancer, Imperial College London, 10(th) Floor QEQM Building, St Mary's Hospital, Praed Street, London, W2 1NY, UK.
| | - Celia Riga
- Imperial Vascular Unit, Imperial College Healthcare NHS Trust, London, UK; Department of Surgery and Cancer, Imperial College London, 10(th) Floor QEQM Building, St Mary's Hospital, Praed Street, London, W2 1NY, UK
| |
Collapse
|
9
|
Development of a Robotic Catheter Manipulation System Based on BP Neural Network PID Controller. Appl Bionics Biomech 2020; 2020:8870106. [PMID: 33425007 PMCID: PMC7775165 DOI: 10.1155/2020/8870106] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 10/15/2020] [Accepted: 12/05/2020] [Indexed: 11/23/2022] Open
Abstract
In the process of artificial interventional therapy, the operation of artificial catheter is not accurate, which will bring strong radiation damage to surgeons. The purpose of this study is to develop a catheter operating system of surgical robot to assist doctors in remote operation and avoid the influence of radiation. BP neural network plays an important role in the flexibility and rapidity of control. According to the actual output of the system, the control parameters of the controller are constantly adjusted to achieve better output effect. This paper introduces the practical application of BP neural network PID controller in the remote operation of the system and compares with the traditional PID controller. The results show that the new control algorithm is feasible and effective. The results show that the synchronization performance of BP neural network PID controller is better than that of traditional PID controller.
Collapse
|
10
|
Zhao Y, Guo S, Xiao N, Wang Y, Li Y, Jiang Y. Operating force information on-line acquisition of a novel slave manipulator for vascular interventional surgery. Biomed Microdevices 2018; 20:33. [PMID: 29610988 DOI: 10.1007/s10544-018-0275-7] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Vascular interventional surgery has its advantages compared to traditional operation. Master-slave robotic technology can further improve the operation accuracy, efficiency and safety of this complicated and high risk surgery. However, on-line acquisition of operating force information of catheter and guidewire remains to be a significant obstacle on the path to enhancing robotic surgery safety. Thus, a novel slave manipulator is proposed in this paper to realize on-line sensing of guidewire torsional operating torque and axial operation force during robotic assisted operations. A strain sensor is specially designed to detect the small scale torsional operation torque with low rotational frequency. Additionally, the axial operating force is detected via a load cell, which is incorporated into a sliding mechanism to eliminate the influence of friction. For validation, calibration and performance evaluation experiments are conducted. The results indicate that the proposed operation torque and force detection device is effective. Thus, it can provide the foundation for enabling accurate haptic feedback to the surgeon to improve surgical safety.
Collapse
Affiliation(s)
- Yan Zhao
- Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China
| | - Shuxiang Guo
- Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
- Faculty of Engineering, Kagawa University, 2217-20 Hayashi-cho, Takamatsu, Kagawa, 760-8521, Japan.
| | - Nan Xiao
- Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
| | - Yuxin Wang
- Key Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China
| | - Youxiang Li
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050, China
| | - Yuhua Jiang
- Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050, China
| |
Collapse
|
11
|
Guo J, Jin X, Guo S. Study of the Operational Safety of a Vascular Interventional Surgical Robotic System. MICROMACHINES 2018; 9:mi9030119. [PMID: 30424053 PMCID: PMC6187718 DOI: 10.3390/mi9030119] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 03/01/2018] [Accepted: 03/06/2018] [Indexed: 12/26/2022]
Abstract
This paper proposes an operation safety early warning system based on LabView (2014, National Instruments Corporation, Austin, TX, USA) for vascular interventional surgery (VIS) robotic system. The system not only provides intuitive visual feedback information for the surgeon, but also has a safety early warning function. It is well known that blood vessels differ in their ability to withstand stress in different age groups, therefore, the operation safety early warning system based on LabView has a vascular safety threshold function that changes in real-time, which can be oriented to different age groups of patients and a broader applicable scope. In addition, the tracing performance of the slave manipulator to the master manipulator is also an important index for operation safety. Therefore, we also transformed the slave manipulator and integrated the displacement error compensation algorithm in order to improve the tracking ability of the slave manipulator to the master manipulator and reduce master–slave tracking errors. We performed experiments “in vitro” to validate the proposed system. According to previous studies, 0.12 N is the maximum force when the blood vessel wall has been penetrated. Experimental results showed that the proposed operation safety early warning system based on LabView combined with operating force feedback can effectively avoid excessive collisions between the surgical catheter and vessel wall to avoid vascular puncture. The force feedback error of the proposed system is maintained between ±20 mN, which is within the allowable safety range and meets our design requirements. Therefore, the proposed system can ensure the safety of surgery.
Collapse
Affiliation(s)
- Jian Guo
- Key Laboratory for Control Theory and Application in Complicated Systems and Biomedical Robot Laboratory, Tianjin University of Technology, Tianjin 300384, China.
| | - Xiaoliang Jin
- Key Laboratory for Control Theory and Application in Complicated Systems and Biomedical Robot Laboratory, Tianjin University of Technology, Tianjin 300384, China.
| | - Shuxiang Guo
- Key Laboratory for Control Theory and Application in Complicated Systems and Biomedical Robot Laboratory, Tianjin University of Technology, Tianjin 300384, China.
- School of Life Science, Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, The Institute of Advanced Biomedical Engineering System, Beijing Institute of Technology, Beijing 100081, China.
- Intelligent Mechanical Systems Engineering Department, Kagawa University, Takamatsu 761-0396, Japan.
| |
Collapse
|