1
|
Reconsidering Race Adjustment in Prenatal Alpha-Fetoprotein Screening. Obstet Gynecol 2023; 141:438-444. [PMID: 36735409 DOI: 10.1097/aog.0000000000005045] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 10/07/2022] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Black racial designation is the only race for which adjustment is recommended for maternal prenatal serum alpha-fetoprotein (AFP) screening. The objective of this study is to reevaluate the relationship between maternal race and maternal serum AFP values in prenatal analyte screening. METHODS This was a single-center retrospective analysis of patients who underwent prenatal analyte screening between January 2007 and December 2020. Nomograms for raw maternal serum AFP values by gestational age were created and compared between patients identified as "Black" and "non-Black" on the laboratory requisition. Multivariable linear regression models were created to evaluate the relationship among gestational age, maternal weight, and maternal race on maternal serum AFP levels. The new models were compared with the laboratory-derived calculations, which used historically determined race adjustments. RESULTS A total of 43,997 patients underwent analyte screening, and 27,710 patients had complete data for analysis. Of these, 6% were identified as Black. Black patients had laboratory blood draws at a mean gestational age of 123 days, compared with 120 days in non-Black patients ( P <.001), and had higher maternal weight (mean 170 vs 161 lbs, P <.001). Nomograms for raw maternal serum AFP values did not differ between Black and non-Black patients ( P =.065). When adjusted for gestational age and maternal weight, no difference in maternal serum AFP values was identified between Black and non-Black individuals ( P =.81). CONCLUSION No difference in maternal serum AFP values was identified between Black and non-Black pregnant individuals when adjusted by maternal weight and gestational age at blood draw. These findings suggest that routine race-based adjustment of maternal serum AFP screening should be discontinued.
Collapse
|
2
|
Alldred SK, Takwoingi Y, Guo B, Pennant M, Deeks JJ, Neilson JP, Alfirevic Z. First trimester ultrasound tests alone or in combination with first trimester serum tests for Down's syndrome screening. Cochrane Database Syst Rev 2017; 3:CD012600. [PMID: 28295158 PMCID: PMC6464518 DOI: 10.1002/14651858.cd012600] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Down's syndrome occurs when a person has three, rather than two copies of chromosome 21; or the specific area of chromosome 21 implicated in causing Down's syndrome. It is the commonest congenital cause of mental disability and also leads to numerous metabolic and structural problems. It can be life-threatening, or lead to considerable ill health, although some individuals have only mild problems and can lead relatively normal lives. Having a baby with Down's syndrome is likely to have a significant impact on family life.Non-invasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing.Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive and false negative screening tests (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. OBJECTIVES To estimate and compare the accuracy of first trimester ultrasound markers alone, and in combination with first trimester serum tests for the detection of Down's syndrome. SEARCH METHODS We carried out extensive literature searches including MEDLINE (1980 to 25 August 2011), Embase (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), and The Database of Abstracts of Reviews of Effects (the Cochrane Library 2011, Issue 7). We checked reference lists and published review articles for additional potentially relevant studies. SELECTION CRITERIA Studies evaluating tests of first trimester ultrasound screening, alone or in combination with first trimester serum tests (up to 14 weeks' gestation) for Down's syndrome, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. DATA COLLECTION AND ANALYSIS Data were extracted as test positive/test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS criteria. We used hierarchical summary ROC meta-analytical methods to analyse test performance and compare test accuracy. Analysis of studies allowing direct comparison between tests was undertaken. We investigated the impact of maternal age on test performance in subgroup analyses. MAIN RESULTS We included 126 studies (152 publications) involving 1,604,040 fetuses (including 8454 Down's syndrome cases). Studies were generally good quality, although differential verification was common with invasive testing of only high-risk pregnancies. Sixty test combinations were evaluated formed from combinations of 11 different ultrasound markers (nuchal translucency (NT), nasal bone, ductus venosus Doppler, maxillary bone length, fetal heart rate, aberrant right subclavian artery, frontomaxillary facial angle, presence of mitral gap, tricuspid regurgitation, tricuspid blood flow and iliac angle 90 degrees); 12 serum tests (inhibin A, alpha-fetoprotein (AFP), free beta human chorionic gonadotrophin (ßhCG), total hCG, pregnancy-associated plasma protein A (PAPP-A), unconjugated oestriol (uE3), disintegrin and metalloprotease 12 (ADAM 12), placental growth factor (PlGF), placental growth hormone (PGH), invasive trophoblast antigen (ITA) (synonymous with hyperglycosylated hCG), growth hormone binding protein (GHBP) and placental protein 13 (PP13)); and maternal age. The most frequently evaluated serum markers in combination with ultrasound markers were PAPP-A and free ßhCG.Comparisons of the 10 most frequently evaluated test strategies showed that a combined NT, PAPP-A, free ßhCG and maternal age test strategy significantly outperformed ultrasound markers alone (with or without maternal age) except nasal bone, detecting about nine out of every 10 Down's syndrome pregnancies at a 5% false positive rate (FPR). In both direct and indirect comparisons, the combined NT, PAPP-A, free ßhCG and maternal age test strategy showed superior diagnostic accuracy to an NT and maternal age test strategy (P < 0.0001). Based on the indirect comparison of all available studies for the two tests, the sensitivity (95% confidence interval) estimated at a 5% FPR for the combined NT, PAPP-A, free ßhCG and maternal age test strategy (69 studies; 1,173,853 fetuses including 6010 with Down's syndrome) was 87% (86 to 89) and for the NT and maternal age test strategy (50 studies; 530,874 fetuses including 2701 Down's syndrome pregnancies) was 71% (66 to 75). Combinations of NT with other ultrasound markers, PAPP-A and free ßhCG were evaluated in one or two studies and showed sensitivities of more than 90% and specificities of more than 95%.High-risk populations (defined before screening was done, mainly due to advanced maternal age of 35 years or more, or previous pregnancies affected with Down's syndrome) showed lower detection rates compared to routine screening populations at a 5% FPR. Women who miscarried in the over 35 group were more likely to have been offered an invasive test to verify a negative screening results, whereas those under 35 were usually not offered invasive testing for a negative screening result. Pregnancy loss in women under 35 therefore leads to under-ascertainment of screening results, potentially missing a proportion of affected pregnancies and affecting test sensitivity. Conversely, for the NT, PAPP-A, free ßhCG and maternal age test strategy, detection rates and false positive rates increased with maternal age in the five studies that provided data separately for the subset of women aged 35 years or more. AUTHORS' CONCLUSIONS Test strategies that combine ultrasound markers with serum markers, especially PAPP-A and free ßhCG, and maternal age were significantly better than those involving only ultrasound markers (with or without maternal age) except nasal bone. They detect about nine out of 10 Down's affected pregnancies for a fixed 5% FPR. Although the absence of nasal bone appeared to have a high diagnostic accuracy, only five out of 10 affected Down's pregnancies were detected at a 1% FPR.
Collapse
Affiliation(s)
- S Kate Alldred
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | - Yemisi Takwoingi
- University of BirminghamInstitute of Applied Health ResearchEdgbastonBirminghamUKB15 2TT
| | - Boliang Guo
- University of NottinghamSchool of MedicineCLAHRC, C floor, IHM, Jubilee CampusUniversity of Nottingham, Triumph RoadNottinghamEast MidlandsUKNG7 2TU
| | - Mary Pennant
- Cambridgeshire County CouncilPublic Health DirectorateCambridgeUK
| | - Jonathan J Deeks
- University of BirminghamInstitute of Applied Health ResearchEdgbastonBirminghamUKB15 2TT
| | | | - Zarko Alfirevic
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | | |
Collapse
|
3
|
Alldred SK, Takwoingi Y, Guo B, Pennant M, Deeks JJ, Neilson JP, Alfirevic Z. First and second trimester serum tests with and without first trimester ultrasound tests for Down's syndrome screening. Cochrane Database Syst Rev 2017; 3:CD012599. [PMID: 28295159 PMCID: PMC6464364 DOI: 10.1002/14651858.cd012599] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Down's syndrome occurs when a person has three copies of chromosome 21 (or the specific area of chromosome 21 implicated in causing Down's syndrome) rather than two. It is the commonest congenital cause of mental disability. Non-invasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing. Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal) and false negative screening tests (i.e. a fetus with Down's syndrome will be missed). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. OBJECTIVES To estimate and compare the accuracy of first and second trimester serum markers with and without first trimester ultrasound markers for the detection of Down's syndrome in the antenatal period, as combinations of markers. SEARCH METHODS We conducted a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), Embase (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), the Database of Abstracts of Reviews of Effectiveness (the Cochrane Library 25 August 2011), MEDION (25 August 2011), the Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), the National Research Register (Archived 2007), and Health Services Research Projects in Progress database (25 August 2011). We did not apply a diagnostic test search filter. We did forward citation searching in ISI citation indices, Google Scholar and PubMed 'related articles'. We also searched reference lists of retrieved articles SELECTION CRITERIA: Studies evaluating tests of combining first and second trimester maternal serum markers in women up to 24 weeks of gestation for Down's syndrome, with or without first trimester ultrasound markers, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. DATA COLLECTION AND ANALYSIS Data were extracted as test positive/test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS criteria. We used hierarchical summary ROC meta-analytical methods to analyse test performance and compare test accuracy. Analysis of studies allowing direct comparison between tests was undertaken. We investigated the impact of maternal age on test performance in subgroup analyses. MAIN RESULTS Twenty-two studies (reported in 25 publications) involving 228,615 pregnancies (including 1067 with Down's syndrome) were included. Studies were generally high quality, although differential verification was common with invasive testing of only high risk pregnancies. Ten studies made direct comparisons between tests. Thirty-two different test combinations were evaluated formed from combinations of eight different tests and maternal age; first trimester nuchal translucency (NT) and the serum markers AFP, uE3, total hCG, free βhCG, Inhibin A, PAPP-A and ADAM 12. We looked at tests combining first and second trimester markers with or without ultrasound as complete tests, and we also examined stepwise and contingent strategies.Meta-analysis of the six most frequently evaluated test combinations showed that a test strategy involving maternal age and a combination of first trimester NT and PAPP-A, and second trimester total hCG, uE3, AFP and Inhibin A significantly outperformed other test combinations that involved only one serum marker or NT in the first trimester, detecting about nine out of every 10 Down's syndrome pregnancies at a 5% false positive rate. However, the evidence was limited in terms of the number of studies evaluating this strategy, and we therefore cannot recommend one single screening strategy. AUTHORS' CONCLUSIONS Tests involving first trimester ultrasound with first and second trimester serum markers in combination with maternal age are significantly better than those without ultrasound, or those evaluating first trimester ultrasound in combination with second trimester serum markers, without first trimester serum markers. We cannot make recommendations about a specific strategy on the basis of the small number of studies available.
Collapse
Affiliation(s)
- S Kate Alldred
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | - Yemisi Takwoingi
- University of BirminghamInstitute of Applied Health ResearchEdgbastonBirminghamUKB15 2TT
| | - Boliang Guo
- University of NottinghamSchool of MedicineCLAHRC, C floor, IHM, Jubilee CampusUniversity of Nottingham, Triumph RoadNottinghamEast MidlandsUKNG7 2TU
| | - Mary Pennant
- Cambridgeshire County CouncilPublic Health DirectorateCambridgeUK
| | - Jonathan J Deeks
- University of BirminghamInstitute of Applied Health ResearchEdgbastonBirminghamUKB15 2TT
| | | | - Zarko Alfirevic
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | | |
Collapse
|
4
|
Alldred SK, Guo B, Takwoingi Y, Pennant M, Wisniewski S, Deeks JJ, Neilson JP, Alfirevic Z. Urine tests for Down's syndrome screening. Cochrane Database Syst Rev 2015; 2015:CD011984. [PMID: 26662198 PMCID: PMC7081127 DOI: 10.1002/14651858.cd011984] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Down's syndrome occurs when a person has three copies of chromosome 21, or the specific area of chromosome 21 implicated in causing Down's syndrome, rather than two. It is the commonest congenital cause of mental disability and also leads to numerous metabolic and structural problems. It can be life-threatening, or lead to considerable ill health, although some individuals have only mild problems and can lead relatively normal lives. Having a baby with Down's syndrome is likely to have a significant impact on family life. The risk of a Down's syndrome affected pregnancy increases with advancing maternal age.Noninvasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing. Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive and false negative screening tests (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. OBJECTIVES To estimate and compare the accuracy of first and second trimester urine markers for the detection of Down's syndrome. SEARCH METHODS We carried out a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), EMBASE (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), The Database of Abstracts of Reviews of Effectiveness (The Cochrane Library 2011, Issue 7), MEDION (25 August 2011), The Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), The National Research Register (archived 2007), Health Services Research Projects in Progress database (25 August 2011). We studied reference lists and published review articles. SELECTION CRITERIA Studies evaluating tests of maternal urine in women up to 24 weeks of gestation for Down's syndrome, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. DATA COLLECTION AND ANALYSIS We extracted data as test positive or test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS (Quality Assessment of Diagnostic Accuracy Studies) criteria. We used hierarchical summary ROC (receiver operating characteristic) meta-analytical methods to analyse test performance and compare test accuracy. We performed analysis of studies allowing direct comparison between tests. We investigated the impact of maternal age on test performance in subgroup analyses. MAIN RESULTS We included 19 studies involving 18,013 pregnancies (including 527 with Down's syndrome). Studies were generally of high quality, although differential verification was common with invasive testing of only high-risk pregnancies. Twenty-four test combinations were evaluated formed from combinations of the following seven different markers with and without maternal age: AFP (alpha-fetoprotein), ITA (invasive trophoblast antigen), ß-core fragment, free ßhCG (beta human chorionic gonadotrophin), total hCG, oestriol, gonadotropin peptide and various marker ratios. The strategies evaluated included three double tests and seven single tests in combination with maternal age, and one triple test, two double tests and 11 single tests without maternal age. Twelve of the 19 studies only evaluated the performance of a single test strategy while the remaining seven evaluated at least two test strategies. Two marker combinations were evaluated in more than four studies; second trimester ß-core fragment (six studies), and second trimester ß-core fragment with maternal age (five studies).In direct test comparisons, for a 5% false positive rate (FPR), the diagnostic accuracy of the double marker second trimester ß-core fragment and oestriol with maternal age test combination was significantly better (ratio of diagnostic odds ratio (RDOR): 2.2 (95% confidence interval (CI) 1.1 to 4.5), P = 0.02) (summary sensitivity of 73% (CI 57 to 85) at a cut-point of 5% FPR) than that of the single marker test strategy of second trimester ß-core fragment and maternal age (summary sensitivity of 56% (CI 45 to 66) at a cut-point of 5% FPR), but was not significantly better (RDOR: 1.5 (0.8 to 2.8), P = 0.21) than that of the second trimester ß-core fragment to oestriol ratio and maternal age test strategy (summary sensitivity of 71% (CI 51 to 86) at a cut-point of 5% FPR). AUTHORS' CONCLUSIONS Tests involving second trimester ß-core fragment and oestriol with maternal age are significantly more sensitive than the single marker second trimester ß-core fragment and maternal age, however, there were few studies. There is a paucity of evidence available to support the use of urine testing for Down's syndrome screening in clinical practice where alternatives are available.
Collapse
Affiliation(s)
- S Kate Alldred
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | - Boliang Guo
- University of NottinghamSchool of MedicineCLAHRC, C floor, IHM, Jubilee CampusUniversity of Nottingham, Triumph RoadNottinghamEast MidlandsUKNG7 2TU
| | - Yemisi Takwoingi
- University of BirminghamPublic Health, Epidemiology and BiostatisticsEdgbastonBirminghamUKB15 2TT
| | - Mary Pennant
- Cambridgeshire County CouncilPublic Health DirectorateCambridgeUK
| | - Susanna Wisniewski
- Cochrane Dementia and Cognitive Improvement Group, Oxford UniversityOxfordUK
| | - Jonathan J Deeks
- University of BirminghamPublic Health, Epidemiology and BiostatisticsEdgbastonBirminghamUKB15 2TT
| | - James P Neilson
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | - Zarko Alfirevic
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | | |
Collapse
|
5
|
Alldred SK, Takwoingi Y, Guo B, Pennant M, Deeks JJ, Neilson JP, Alfirevic Z. First trimester serum tests for Down's syndrome screening. Cochrane Database Syst Rev 2015; 2015:CD011975. [PMID: 26617074 PMCID: PMC6465076 DOI: 10.1002/14651858.cd011975] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND Down's syndrome occurs when a person has three, rather than two copies of chromosome 21; or the specific area of chromosome 21 implicated in causing Down's syndrome. It is the commonest congenital cause of mental disability and also leads to numerous metabolic and structural problems. It can be life-threatening, or lead to considerable ill health, although some individuals have only mild problems and can lead relatively normal lives. Having a baby with Down's syndrome is likely to have a significant impact on family life.Noninvasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing. However, no test can predict the severity of problems a person with Down's syndrome will have. OBJECTIVES The aim of this review was to estimate and compare the accuracy of first trimester serum markers for the detection of Down's syndrome in the antenatal period, both as individual markers and as combinations of markers. Accuracy is described by the proportion of fetuses with Down's syndrome detected by screening before birth (sensitivity or detection rate) and the proportion of women with a low risk (normal) screening test result who subsequently had a baby unaffected by Down's syndrome (specificity). SEARCH METHODS We conducted a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), Embase (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), The Database of Abstracts of Reviews of Effectiveness (The Cochrane Library 25 August 2011), MEDION (25 August 2011), The Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), The National Research Register (Archived 2007), Health Services Research Projects in Progress database (25 August 2011). We did forward citation searching ISI citation indices, Google Scholar and PubMed 'related articles'. We did not apply a diagnostic test search filter. We also searched reference lists and published review articles. SELECTION CRITERIA We included studies in which all women from a given population had one or more index test(s) compared to a reference standard (either chromosomal verification or macroscopic postnatal inspection). Both consecutive series and diagnostic case-control study designs were included. Randomised trials where individuals were randomised to different screening strategies and all verified using a reference standard were also eligible for inclusion. Studies in which test strategies were compared head-to-head either in the same women, or between randomised groups were identified for inclusion in separate comparisons of test strategies. We excluded studies if they included less than five Down's syndrome cases, or more than 20% of participants were not followed up. DATA COLLECTION AND ANALYSIS We extracted data as test positive or test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS (Quality Assessment of Diagnostic Accuracy Studies) criteria. We used hierarchical summary ROC meta-analytical methods or random-effects logistic regression methods to analyse test performance and compare test accuracy as appropriate. Analyses of studies allowing direct and indirect comparisons between tests were undertaken. MAIN RESULTS We included 56 studies (reported in 68 publications) involving 204,759 pregnancies (including 2113 with Down's syndrome). Studies were generally of good quality, although differential verification was common with invasive testing of only high-risk pregnancies. We evaluated 78 test combinations formed from combinations of 18 different tests, with or without maternal age; ADAM12 (a disintegrin and metalloprotease), AFP (alpha-fetoprotein), inhibin, PAPP-A (pregnancy-associated plasma protein A, ITA (invasive trophoblast antigen), free βhCG (beta human chorionic gonadotrophin), PlGF (placental growth factor), SP1 (Schwangerschafts protein 1), total hCG, progesterone, uE3 (unconjugated oestriol), GHBP (growth hormone binding protein), PGH (placental growth hormone), hyperglycosylated hCG, ProMBP (proform of eosinophil major basic protein), hPL (human placental lactogen), (free αhCG, and free ßhCG to AFP ratio. Direct comparisons between two or more tests were made in 27 studies.Meta-analysis of the nine best performing or frequently evaluated test combinations showed that a test strategy involving maternal age and a double marker combination of PAPP-A and free ßhCG significantly outperformed the individual markers (with or without maternal age) detecting about seven out of every 10 Down's syndrome pregnancies at a 5% false positive rate (FPR). Limited evidence suggested that marker combinations involving PAPP-A may be more sensitive than those without PAPP-A. AUTHORS' CONCLUSIONS Tests involving two markers in combination with maternal age, specifically PAPP-A, free βhCG and maternal age are significantly better than those involving single markers with and without age. They detect seven out of 10 Down's affected pregnancies for a fixed 5% FPR. The addition of further markers (triple tests) has not been shown to be statistically superior; the studies included are small with limited power to detect a difference.The screening blood tests themselves have no adverse effects for the woman, over and above the risks of a routine blood test. However some women who have a 'high risk' screening test result, and are given amniocentesis or chorionic villus sampling (CVS) have a risk of miscarrying a baby unaffected by Down's. Parents will need to weigh up this risk when deciding whether or not to have an amniocentesis or CVS following a 'high risk' screening test result.
Collapse
Affiliation(s)
- S Kate Alldred
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | - Yemisi Takwoingi
- University of BirminghamPublic Health, Epidemiology and BiostatisticsEdgbastonBirminghamUKB15 2TT
| | - Boliang Guo
- University of NottinghamSchool of MedicineCLAHRC, C floor, IHM, Jubilee CampusUniversity of Nottingham, Triumph RoadNottinghamEast MidlandsUKNG7 2TU
| | - Mary Pennant
- Cambridgeshire County CouncilPublic Health DirectorateCambridgeUK
| | - Jonathan J Deeks
- University of BirminghamPublic Health, Epidemiology and BiostatisticsEdgbastonBirminghamUKB15 2TT
| | - James P Neilson
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | - Zarko Alfirevic
- The University of LiverpoolDepartment of Women's and Children's HealthFirst Floor, Liverpool Women's NHS Foundation TrustCrown StreetLiverpoolUKL8 7SS
| | | |
Collapse
|
6
|
Reference ranges and determinants of total hCG levels during pregnancy: the Generation R Study. Eur J Epidemiol 2015; 30:1057-66. [PMID: 25963653 PMCID: PMC4584104 DOI: 10.1007/s10654-015-0039-0] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Accepted: 05/04/2015] [Indexed: 01/01/2023]
Abstract
Human chorionic gonadotropin (hCG) is a pregnancy hormone secreted by the placental synctiotrophoblast cell layer that has been linked to fetal growth and various placental, uterine and fetal functions. In order to investigate the effects of hCG on clinical endpoints, knowledge on reference range (RR) methodology and determinants of gestational hCG levels is crucial. Moreover, a better understanding of gestational hCG physiology can improve current screening programs and future clinical management. Serum total hCG levels were determined in 8195 women participating in the Generation R Study. Gestational age specific RRs using ‘ultrasound derived gestational age’ (US RRs) were calculated and compared with ‘last menstrual period derived gestational age’ (LMP RRs) and a model-based RR. We also investigated which pregnancy characteristics were associated with hCG levels. Compared to the US RRs, the LMP RRs were lower, most notably for the median and lower limit levels. No considerable differences were found between RRs calculated in the general population or in uncomplicated pregnancies only. Maternal smoking, BMI, parity, ethnicity, fetal gender, placental weight and hyperemesis gravidarum symptoms were associated with total hCG. We provide gestational RRs for total hCG and show that total hCG values and RR cut-offs during pregnancy vary depending on pregnancy dating methodology. This is likely due to the influence of hCG on embryonic growth, suggesting that ultrasound based pregnancy dating might be less reliable in women with high/low hCG levels. Furthermore, we identify different pregnancy characteristics that influence total hCG levels considerably and should therefore be accounted for in clinical studies.
Collapse
|
7
|
Toriola AT, Tolockiene E, Schock H, Surcel HM, Zeleniuch-Jacquotte A, Wadell G, Toniolo P, Lundin E, Grankvist K, Lukanova A. Free β-human chorionic gonadotropin, total human chorionic gonadotropin and maternal risk of breast cancer. Future Oncol 2014; 10:377-84. [PMID: 24559445 DOI: 10.2217/fon.13.208] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND We investigated whether the free β-human chorionic gonadotropin (free β-hCG) would provide additional information to that provided by total hCG alone and thus be useful in future epidemiological studies relating hCG to maternal breast cancer risk. MATERIALS & METHODS Cases (n = 159) and controls (n = 286) were a subset of our previous study within the Northern Sweden Maternity Cohort on total hCG during primiparous pregnancy and breast cancer risk. RESULTS The associations between total hCG (hazard ratio: 0.79; 95% CI: 0.49-1.27), free β-hCG (hazard ratio: 0.85; 95% CI: 0.33-2.18) and maternal risk of breast cancer were very similar in all analyses and mutual adjustment for either one had minor effects on the risk estimates. CONCLUSION In the absence of a reliable assay on intact hCG, total hCG alone can be used in epidemiological studies investigating hCG and breast cancer risk, as free β-hCG does not appear to provide any additional information.
Collapse
Affiliation(s)
- Adetunji T Toriola
- Division of Public Health Sciences, Department of Surgery & Siteman Cancer Center, Washington University School of Medicine, St Louis, MO, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Alldred SK, Deeks JJ, Guo B, Neilson JP, Alfirevic Z. Second trimester serum tests for Down's Syndrome screening. Cochrane Database Syst Rev 2012; 2012:CD009925. [PMID: 22696388 PMCID: PMC7086392 DOI: 10.1002/14651858.cd009925] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Down's syndrome occurs when a person has three copies of chromosome 21 - or the specific area of chromosome 21 implicated in causing Down's syndrome - rather than two. It is the commonest congenital cause of mental retardation. Noninvasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing. OBJECTIVES To estimate and compare the accuracy of second trimester serum markers for the detection of Down's syndrome. SEARCH METHODS We carried out a sensitive and comprehensive literature search of MEDLINE (1980 to May 2007), EMBASE (1980 to 18 May 2007), BIOSIS via EDINA (1985 to 18 May 2007), CINAHL via OVID (1982 to 18 May 2007), The Database of Abstracts of Reviews of Effectiveness (The Cochrane Library 2007, Issue 1), MEDION (May 2007), The Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (May 2007), The National Research Register (May 2007), Health Services Research Projects in Progress database (May 2007). We studied reference lists and published review articles. SELECTION CRITERIA Studies evaluating tests of maternal serum in women at 14-24 weeks of gestation for Down's syndrome, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. DATA COLLECTION AND ANALYSIS Data were extracted as test positive/test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS criteria. We used hierarchical summary ROC meta-analytical methods to analyse test performance and compare test accuracy. Analysis of studies allowing direct comparison between tests was undertaken. We investigated the impact of maternal age on test performance in subgroup analyses. MAIN RESULTS Fifty-nine studies involving 341,261 pregnancies (including 1,994 with Down's syndrome) were included. Studies were generally high quality, although differential verification was common with invasive testing of only high-risk pregnancies. Seventeen studies made direct comparisons between tests. Fifty-four test combinations were evaluated formed from combinations of 12 different tests and maternal age; alpha-fetoprotein (AFP), unconjugated oestriol (uE3), total human chorionic gonadotrophin (hCG), free beta human chorionic gonadotrophin (βhCG), free alpha human chorionic gonadotrophin (αhCG), Inhibin A, SP2, CA125, troponin, pregnancy-associated plasma protein A (PAPP-A), placental growth factor (PGF) and proform of eosinophil major basic protein (ProMBP).Meta-analysis of 12 best performing or frequently evaluated test combinations showed double and triple tests (involving AFP, uE3, total hCG, free βhCG) significantly outperform individual markers, detecting six to seven out of every 10 Down's syndrome pregnancies at a 5% false positive rate. Tests additionally involving inhibin performed best (eight out of every 10 Down's syndrome pregnancies) but were not shown to be significantly better than standard triple tests in direct comparisons. Significantly lower sensitivity occurred in women over the age of 35 years. Women who miscarried in the over 35 group were more likely to have been offered an invasive test to verify a negative screening results, whereas those under 35 were usually not offered invasive testing for a negative screening result. Pregnancy loss in women under 35 therefore leads to under ascertainment of screening results, potentially missing a proportion of affected pregnancies and affecting the accuracy of the sensitivity. AUTHORS' CONCLUSIONS Tests involving two or more markers in combination with maternal age are significantly more sensitive than those involving one marker. The value of combining four or more tests or including inhibin have not been proven to show statistically significant improvement. Further study is required to investigate reduced test performance in women aged over 35 and the impact of differential pregnancy loss on study findings.
Collapse
Affiliation(s)
- S Kate Alldred
- Department of Women’s and Children’s Health, The University of Liverpool, Liverpool, UK.
| | | | | | | | | |
Collapse
|
9
|
Järvelä IY, Žáčková T, Laitinen P, Ryynänen M, Tekay A. Effect of parity and fetal sex on placental and luteal hormones during early first trimester. Prenat Diagn 2012; 32:160-7. [DOI: 10.1002/pd.2921] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Ilkka Y. Järvelä
- Departments of Obstetrics and Gynecology; Oulu University Hospital; Oulu; Finland
| | - Tamara Žáčková
- Institute for the Care of Mother and Child Department of IVF; Charles University; Prague; Czech Republic
| | | | - Markku Ryynänen
- Departments of Obstetrics and Gynecology; Oulu University Hospital; Oulu; Finland
| | - Aydin Tekay
- Departments of Obstetrics and Gynecology; Oulu University Hospital; Oulu; Finland
| |
Collapse
|
10
|
Zhang J, Lambert-Messerlian G, Palomaki GE, Canick JA. Impact of smoking on maternal serum markers and prenatal screening in the first and second trimesters. Prenat Diagn 2011; 31:583-8. [DOI: 10.1002/pd.2755] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2011] [Revised: 02/28/2011] [Accepted: 03/01/2011] [Indexed: 11/05/2022]
|
11
|
Maternal hormones during early pregnancy: a cross-sectional study. Cancer Causes Control 2010; 21:719-27. [PMID: 20084544 DOI: 10.1007/s10552-009-9500-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2009] [Accepted: 12/29/2009] [Indexed: 01/29/2023]
Abstract
BACKGROUND Little is known about correlates of first-trimester pregnancy hormones as in most studies maternal hormones have been measured later in gestation. We examined the associations of maternal characteristics and child sex with first-trimester maternal concentrations of four hormones implicated in breast cancer: human chorionic gonadotropin (hCG), alpha-fetoprotein (AFP), insulin-like growth factor (IGF)-I, and IGF-II. METHODS About 338 serum samples donated to the Northern Sweden Maternity Cohort (NSMC), 1975-2001, during the first trimester of uncomplicated pregnancies, were analyzed for the hormones of interest as a part of a case-control study. The associations of maternal characteristics and child sex with hormone concentrations were investigated by correlation, general linear regression, and multivariate regression models. RESULTS In the first trimester, greater maternal age was inversely correlated with IGF-I and IGF-II. In comparison with women carrying their first child, already parous women had higher IGF-I but lower hCG. Greater maternal weight and smoking were inversely correlated with hCG. No differences in hormone levels by child sex were observed. CONCLUSIONS Our analyses indicated that potentially modifiable maternal characteristics (maternal weight and smoking) influence first-trimester pregnancy maternal hormone concentrations.
Collapse
|
12
|
Lukanova A, Andersson R, Wulff M, Zeleniuch-Jacquotte A, Grankvist K, Dossus L, Afanasyeva Y, Johansson R, Arslan AA, Lenner P, Wadell G, Hallmans G, Toniolo P, Lundin E. Human chorionic gonadotropin and alpha-fetoprotein concentrations in pregnancy and maternal risk of breast cancer: a nested case-control study. Am J Epidemiol 2008; 168:1284-91. [PMID: 18936438 DOI: 10.1093/aje/kwn254] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Pregnancy hormones are believed to be involved in the protection against breast cancer conferred by pregnancy. The authors explored the association of maternal breast cancer with human chorionic gonadotropin (hCG) and alpha-fetoprotein (AFP). In 2001, a case-control study was nested within the Northern Sweden Maternity Cohort, an ongoing study in which blood samples have been collected from first-trimester pregnant women since 1975. Cases (n = 210) and controls (n = 357) were matched for age, parity, and date of blood donation. Concentrations of hCG and AFP were measured by immunoassay. No overall significant association of breast cancer with either hCG or AFP was observed. However, women with hCG levels in the top tertile tended to be at lower risk of breast cancer than women with hCG levels in the lowest tertile in the whole study population and in subgroups of age at sampling, parity, and age at cancer diagnosis. A borderline-significant decrease in risk with high hCG levels was observed in women who developed breast cancer after the median lag time to cancer diagnosis (> or =14 years; odds ratio = 0.53, 95% confidence interval: 0.27, 1.03; P = 0.06). These findings, though very preliminary, are consistent with a possible long-term protective association of breast cancer risk with elevated levels of circulating hCG in the early stages of pregnancy.
Collapse
|
13
|
Haddow JE, McClain MR, Lambert-Messerlian G, Palomaki GE, Canick JA, Cleary-Goldman J, Malone FD, Porter TF, Nyberg DA, Bernstein P, D'Alton ME. Variability in thyroid-stimulating hormone suppression by human chorionic [corrected] gonadotropin during early pregnancy. J Clin Endocrinol Metab 2008; 93:3341-7. [PMID: 18544616 PMCID: PMC2567848 DOI: 10.1210/jc.2008-0568] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
OBJECTIVE The objective of the study was to further explore relationships between human chorionic gonadotropin (hCG), TSH, and free T4 in pregnant women at 11 through 18 wk gestation. STUDY DESIGN The design of the study was to analyze hCG in comparison with TSH and free T4, in paired first- and second-trimester sera from 9562 women in the First and Second Trimester Evaluation of Risk for Fetal Aneuploidy trial study. RESULTS hCG is strongly correlated with body mass index, smoking, and gravidity. Correlations with selected maternal covariates also exist for TSH and free T4. As hCG deciles increase, body mass index and percent of women who smoke both decrease, whereas the percent of primigravid women increases (P < 0.0001). hCG/TSH correlations are weak in both trimesters (r2 = 0.03 and r2 = 0.02). TSH concentrations at the 25th and fifth centiles become sharply lower at higher hCG levels, whereas 50th centile and above TSH concentrations are only slightly lower. hCG/free T4 correlations are weak in both trimesters (r2 = 0.06 and r2 = 0.003). At 11-13 wk gestation, free T4 concentrations rise uniformly at all centiles, as hCG increases (test for trend, P < 0.0001), but not at 15-18 wk gestation. Multivariate analyses with TSH and free T4 as dependent variables and selected maternal covariates and hCG as independent variables do not alter these observations. CONCLUSIONS In early pregnancy, a woman's centile TSH level appears to determine susceptibility to the TSH being suppressed at any given hCG level, suggesting that hCG itself may be the primary analyte responsible for stimulating the thyroid gland. hCG affects lower centile TSH values disproportionately.
Collapse
Affiliation(s)
- James E Haddow
- The Warren Alpert Medical School of Brown University, Providence, Rhode Island 02903, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Verkleij-Hagoort AC, Ursem NT, Hop WC, Geurts-Moespot A, Steegers EA, Sweep FC, Steegers-Theunissen RP. Complex congenital malformations and the impact of the plasminogen activator system and beta-hCG in amniotic fluid. Eur J Obstet Gynecol Reprod Biol 2006; 135:47-52. [PMID: 17141398 DOI: 10.1016/j.ejogrb.2006.10.033] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2006] [Revised: 08/30/2006] [Accepted: 10/30/2006] [Indexed: 11/20/2022]
Abstract
OBJECTIVE The plasminogen activator system and beta-hCG may affect neural crest cells and angiogenesis, and thereby embryogenesis. Therefore, we investigated these parameters in amniotic fluids of pregnancies with a complex congenital malformation. STUDY DESIGN In a case-control study amniotic fluid samples were collected from 62 pregnancies with a complex congenital malformation and from 110 healthy control pregnancies at an obstetric department of a large university hospital in the Netherlands. We determined concentrations of tissue-type plasminogen activator (tPA), urokinase-type plasminogen activator (uPA), plasminogen activator inhibitors (PAI-1, PAI-2), tPA approximately PAI-1 and uPA approximately PAI-1 complexes, and beta-hCG with enzyme-linked immunosorbent assays. Mann-Whitney U-tests and analysis of covariance, adjusting for gestational and maternal age, were performed for data comparisons. RESULTS Compared with controls, cases demonstrated significantly lower adjusted geometric mean levels of uPA (24%), tPA (> or =19%) and tPA approximately PAI-1 (35%). Cases showed significantly higher adjusted mean levels of beta-hCG (> or =48%) and PAI-2 (10 ng/mL) than controls. Mean PAI-1 and uPA approximately PAI-1 levels were comparable between both groups. CONCLUSIONS Disturbances in the plasminogen activator system and beta-hCG levels are suggested to be involved in the pathogenesis of complex congenital malformations by affecting neural crest cell migration and angiogenesis.
Collapse
Affiliation(s)
- Anna C Verkleij-Hagoort
- Department of Obstetrics and Gynaecology, Division of Obstetrics and Prenatal Medicine, Erasmus MC, University Medical Centre, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
15
|
Brajenović-Milić B, Tislarić D, Zuvić-Butorac M, Bacić J, Petrović O, Ristić S, Mimica M, Kapović M. Elevated second-trimester free beta-hCG as an isolated finding and pregnancy outcomes. Fetal Diagn Ther 2005; 19:483-7. [PMID: 15539871 DOI: 10.1159/000080159] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2003] [Accepted: 10/02/2003] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To investigate the relationship between unexplained elevated second-trimester free beta-human chorionic gonadotropin (beta-hCG) levels and pregnancy complications as well as adverse pregnancy outcomes. METHODS The study cohort comprised 2,110 non-smoking women with chromosomal and structurally normal fetuses at low-risk for both Down's syndrome (risk <1:250) and neural tube defects (maternal serum alpha-fetoprotein <2.0 MoM). A free beta-hCG value of > or =2.0 MoM was used to define the populations with elevated levels of free beta-hCG. Descriptive statistics, chi2 test, Fisher's exact test, and logistic regression analysis were used for statistical analysis, and p < 0.05 was considered statistically significant. RESULTS The mean maternal age of the study group was significantly lower than in controls (27.9 +/- 4.3 and 30.6 +/- 5.1 years, respectively, p < 0.05), while the proportion of primigravidas was significantly higher compared to that of controls (p < 0.05). After adjustment of the 2 groups according to maternal age and parity, we observed an increased incidence of preeclampsia among women with elevated free beta-hCG levels in relation to controls (p < 0.05). However, a logistic regression analysis demonstrated that the free beta-hCG level was not a predictor of the occurrence of preeclampsia. No significant relationship was found with the incidence of gestational diabetes, oligohydramnios, polyhydramnios, pregnancy-related hypertension, intrauterine growth retardation, preterm delivery, spontaneous abortion and stillbirths (p > 0.05).
Collapse
|
16
|
|