1
|
Hicks KB, Brown KD, Selleck AM, Dedmon MM, Thompson NJ. Surgical Outcomes of Modified Technique for Transcutaneous Bone Conduction Hearing Aid Implantation. Laryngoscope 2024; 134:2401-2404. [PMID: 38149671 DOI: 10.1002/lary.31244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 10/11/2023] [Accepted: 12/01/2023] [Indexed: 12/28/2023]
Abstract
OBJECTIVE To detail a modified surgical technique for implantation of the Osia 2 Bone Conduction Hearing Aid (BCHA) system and to assess intra- and postoperative outcomes of this technique. METHODS A retrospective review was performed for cases undergoing implantation of an Osia 2 BCHA at a tertiary academic medical center. Modifications were made to the surgical procedure including: horizontal or curvilinear incisions, placement of the osseointegrated screw slightly superior to the plane of the external auditory canal, and double layer wound closure. Data regarding outcomes including demographics, incision type, surgical time, drilling requirements, and complications were collected using the electronic medical record. RESULTS A total of twenty-eight cases were evaluated with 57.1% and 42.9% utilizing horizontal and curved incisions, respectively. The median age for recipients was 43.1 years with six pediatric cases included in the study. Median operative time was 58 min (43-126 min). The majority of cases required minimal (60.7%) or no drilling (28.6%) with a significant increase in operative time for those requiring moderate drilling versus minimal to no drilling (F = 8.02, p = 0.002). There were no intraoperative complications. One (3.6%) postoperative seroma occurred which resolved with conservative management. CONCLUSION The proposed modified surgical technique is a safe and effective method for implantation of the transcutaneous BCHA system with a low complication rate. Keys include incision design, implant placement, and two-layered closure to minimize wound tension. These modifications can improve ease of the procedure and reduce operative time. These techniques also appear to be applicable to the pediatric population. LEVEL OF EVIDENCE 3 Laryngoscope, 134:2401-2404, 2024.
Collapse
Affiliation(s)
- Kayla B Hicks
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Kevin D Brown
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - A Morgan Selleck
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Matthew M Dedmon
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Nicholas J Thompson
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| |
Collapse
|
2
|
Key S, Mohamed N, Da Cruz M, Kong K, Hasan Z. Systematic Review and Meta-Analysis of a New Active Transcutaneous Bone Conduction Implant. Laryngoscope 2024; 134:1531-1539. [PMID: 37721219 DOI: 10.1002/lary.31053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 08/10/2023] [Accepted: 09/01/2023] [Indexed: 09/19/2023]
Abstract
OBJECTIVE This review aims to quantify the pooled functional gain (FG) in different types of hearing loss with the transcutaneous hearing device, Osia (Cochlear, Sydney, Australia) in comparison with the unaided state. Secondary outcomes are patient-reported outcomes measures (PROMs) and complication rates. DATA SOURCES Medline, Embase, SCOPUS, Cochrane CENTRAL, PROSPERO and Cochrane Library. REVIEW METHODS Systematic review and meta-analysis of indexed search terms relating to "Osia," "Osseointegration," "Cochlear Implant," and "Bone-Anchored Prosthesis" was performed from database inception to September 20, 2022. RESULTS Of the 168 studies identified, 14 studies with 15 patient cohorts (n = 314) met inclusion criteria for meta-analysis. Pooled overall mean FG for all types of hearing loss was 35.0 dB sound pressure level (SPL) (95% confidence interval [CI] 29.12-40.97) compared against unaided hearing. Pooled FG for conductive/mixed hearing loss was 37.7 dB SPL (95% CI 26.1-49.3). Pooled single-sided deafness (SSD) FG could not be calculated due to the small patient cohort for whom SSD data was reported. There is a trend toward improvements in speech receptiveness threshold, signal to noise ratio, and some PROMs compared with baseline hearing. Early complication rates demonstrate risks similar to other transcutaneous implants, with a low predicted explantation (0.11%, 95% CI 0.00%-1.90%) and wound infection rate (1.92% [95% CI 0.00%-6.17%]). No articles directly comparing transcutaneous devices were identified. CONCLUSION The Osia devices demonstrate clear audiologic benefits and a good safety profile for the included patient population. Our study results indicate that frequency-specific gain, PROMs, and the audiological benefit in single-sided deafness may be areas for future prospective research. Laryngoscope, 134:1531-1539, 2024.
Collapse
Affiliation(s)
- Seraphina Key
- Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
| | - Nusrat Mohamed
- Department of Otolaryngology Head and Neck Surgery, Canterbury Hospital, Campsie, New South Wales, Australia
| | - Melville Da Cruz
- Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
- Department of Otolaryngology-Head and Neck Surgery, Westmead Hospital, Sydney, New South Wales, Australia
| | - Kelvin Kong
- Department of Otolaryngology-Head and Neck Surgery, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
- School of Medicine and Public Health, The University of Newcastle, Callaghan, New South Wales, Australia
- Faculty of Medicine, Macquarie University, Macquarie Park, New South Wales, Australia
| | - Zubair Hasan
- Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
- Department of Otolaryngology-Head and Neck Surgery, John Hunter Hospital, New Lambton Heights, New South Wales, Australia
- Department of Otolaryngology-Head and Neck Surgery, The Royal Children's Hospital, Parkville, Victoria, Australia
| |
Collapse
|
3
|
Cowan R, Lewis AT, Hallberg C, Tong MCF, Birman CS, Ng IHY, Briggs R. Clinical performance, safety, and patient-reported outcomes of an active osseointegrated bone-conduction hearing implant system at 24-month follow-up. Eur Arch Otorhinolaryngol 2024; 281:683-691. [PMID: 37552281 PMCID: PMC10796683 DOI: 10.1007/s00405-023-08133-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 07/13/2023] [Indexed: 08/09/2023]
Abstract
PURPOSE To investigate 2-year post-operative hearing performance, safety, and patient-reported outcomes of hearing-impaired adults treated with the Osia® 2 System, an active osseointegrated bone-conduction hearing implant that uses piezoelectric technology. METHODS A prospective, multicenter, open-label, single-arm, within-subject clinical study conducted at three tertiary referral clinical centers located in Melbourne, Sydney and Hong Kong. Twenty adult recipients of the Osia 2 System were enrolled and followed up between 12 and 24 months post-implantation: 17 with mixed or conductive hearing loss and 3 with single-sided sensorineural deafness. Safety data, audiological thresholds, speech recognition thresholds in noise, and patient-reported outcomes were collected and evaluated. In addition, pre-and 6-month post-implantation data were collected retrospectively for this recipient cohort enrolled into the earlier study (ClinicalTrials.gov NCT04041700). RESULTS Between 6- and 24-month follow-up, there was no statistically significant change in free-field hearing thresholds or speech reception thresholds in noise (p = > 0.05), indicating that aided improvements were maintained up to 24 months of follow-up. Furthermore, improvements in health-related quality of life and daily hearing ability, as well as clinical and subjective measures of hearing benefit remained stable over the 24-month period. No serious adverse events were reported during extended follow-up. CONCLUSIONS These study results provide further evidence to support the longer term clinical safety, hearing performance, and patient-related benefits of the Osia 2 System in patients with either a conductive hearing loss, mixed hearing loss, or single-sided sensorineural deafness. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT04754477. First posted: February 15, 2021.
Collapse
Affiliation(s)
- Robert Cowan
- Department of Otolaryngology, The University of Melbourne, Melbourne, Australia
| | | | | | - Michael C F Tong
- Department of Otorhinolaryngology, Head and Neck Surgery and Institute of Human Communicative Research, The Chinese University of Hong Kong, Hong Kong SAR, People's Republic of China
| | - Catherine S Birman
- Nextsense, Sydney, Australia
- Faculty of Medicine and Health, Sydney University, Sydney, Australia
- Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| | - Iris H-Y Ng
- Department of Otorhinolaryngology, Head and Neck Surgery and Institute of Human Communicative Research, The Chinese University of Hong Kong, Hong Kong SAR, People's Republic of China
| | - Robert Briggs
- Department of Otolaryngology, The University of Melbourne, Melbourne, Australia.
| |
Collapse
|
4
|
Young A, Fechtner L, Brennan C, Rende S, Wazen J. Clinical performance, audiological outcomes, and quality of life of the Cochlear Osia ® system. Am J Otolaryngol 2023; 44:103951. [PMID: 37329694 DOI: 10.1016/j.amjoto.2023.103951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Accepted: 06/04/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE The Cochlear Osseointegrated Steady-State Implant Bone Anchored Hearing Device (Osia) is a surgically implanted titanium apparatus that utilizes a piezoelectric actuator under the skin to address conductive and mixed hearing loss as well as single-sided deafness. The purpose of this study is to examine the clinical, audiologic, and quality-of-life outcomes in patients who underwent Osia implantation. METHODS This is a retrospective study analyzing 30 adult patients (age 27-86) with conductive healing loss (CHL), mixed hearing loss (MHL), or single-sided deafness (SSD) who were implanted with the Osia device from January 2020 to April 2023 at a single institution by the senior author. Preoperative speech score testing (CNC, AzBio in quiet, AzBio in noise) were performed in all subjects while unaided, wearing conventional air conduction hearing aids, and wearing a softband BAHA. These preoperative speech scores were then compared to post-implantation speech scores using paired t-test analysis to assess for degree of speech improvement. In order to analyze quality of life after Osia implantation, each patient filled out the Glasgow Benefit Inventory (GBI) survey. The GBI is a series of 18 questions answered using a five-point Likert scale that addresses the changes in general health status, physical health status, psychosocial health status, and social support after a medical intervention. RESULTS CHL, MHL, and SSD patients had significant improvement in hearing and speech recognition scores after Osia implantation compared to preoperative unaided hearing: CNC (14 % vs 80 %, p < 0.0001), AzBio in Quiet (26 % vs 94 %, p < 0.0001), and AzBio in Noise (36 % vs 87 %, p = 0.0001). Preoperative speech scores using the softband BAHA were accurate predictors of post-implantation speech scores and can serve to determine surgical candidacy for the Osia. Post-implantation Glasgow Benefit Inventory patient surveys demonstrated significant improvement in quality of life with patients scoring an average increase of +54.1 points in heath satisfaction. CONCLUSION Adult patients with CHL, MHL, and SSD can receive significant improvement in speech recognition scores after implantation with the Osia device. This translates to improved quality of life, which was confirmed on the post-implantation Glasgow Benefit Inventory patient surveys.
Collapse
Affiliation(s)
- Allen Young
- Silverstein Institute-First Physicians Group of Sarasota, 1901 Floyd Street, Sarasota, FL 34239, United States of America.
| | - Linnea Fechtner
- Grand Valley ENT and Facial Plastics Surgeons, 2373 G Road, Suite 270, Grand Junction, CO 81505, United States of America
| | - Carolyn Brennan
- Silverstein Institute-First Physicians Group of Sarasota, 1901 Floyd Street, Sarasota, FL 34239, United States of America
| | - Sharon Rende
- Silverstein Institute-First Physicians Group of Sarasota, 1901 Floyd Street, Sarasota, FL 34239, United States of America
| | - Jack Wazen
- Silverstein Institute-First Physicians Group of Sarasota, 1901 Floyd Street, Sarasota, FL 34239, United States of America
| |
Collapse
|
5
|
Geerardyn A, De Voecht K, Wouters J, Verhaert N. Electro-vibrational stimulation results in improved speech perception in noise for cochlear implant users with bilateral residual hearing. Sci Rep 2023; 13:11251. [PMID: 37438474 DOI: 10.1038/s41598-023-38468-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Accepted: 07/08/2023] [Indexed: 07/14/2023] Open
Abstract
A cochlear implant is a neuroprosthetic device that can restore speech perception for people with severe to profound hearing loss. Because of recent evolutions, a growing number of people with a cochlear implant have useful residual acoustic hearing. While combined electro-acoustic stimulation has been shown to improve speech perception for this group of people, some studies report limited adoption rates. Here, we present electro-vibrational stimulation as an alternative combined stimulation strategy that similarly targets the full cochlear reserve. This novel strategy combines the electrical stimulation by the cochlear implant with low-frequency bone conduction stimulation. In a first evaluation of electro-vibrational stimulation, speech perception in noise was assessed in 9 subjects with a CI and symmetrical residual hearing. We demonstrate a statistically significant and clinically relevant improvement for speech perception in noise of 1.9 dB signal-to-noise ratio. This effect was observed with a first prototype that provides vibrational stimulation to both ears with limited transcranial attenuation. Future integration of electro-vibrational stimulation into one single implantable device could ultimately allow cochlear implant users to benefit from their low-frequency residual hearing without the need for an additional insert earphone.
Collapse
Affiliation(s)
- Alexander Geerardyn
- ExpORL, Department of Neurosciences, KU Leuven, Leuven, Belgium
- Department of Neurosciences, Leuven Brain Institute, KU Leuven, Leuven, Belgium
- Department of Otorhinolaryngology-Head and Neck Surgery, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Katleen De Voecht
- Department of Otorhinolaryngology-Head and Neck Surgery, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Jan Wouters
- ExpORL, Department of Neurosciences, KU Leuven, Leuven, Belgium
- Department of Neurosciences, Leuven Brain Institute, KU Leuven, Leuven, Belgium
| | - Nicolas Verhaert
- ExpORL, Department of Neurosciences, KU Leuven, Leuven, Belgium.
- Department of Neurosciences, Leuven Brain Institute, KU Leuven, Leuven, Belgium.
- Department of Otorhinolaryngology-Head and Neck Surgery, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium.
| |
Collapse
|
6
|
Schwam ZG, Perez ER, Oh S, Wong K, Fan C, Cosetti MK, Wanna GB. Initial Experience With Two Active Transcutaneous Bone-Anchored Hearing Implants. Otol Neurotol 2022; 43:1212-1215. [PMID: 36075090 DOI: 10.1097/mao.0000000000003681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To analyze our institutional experience with two active transcutaneous bone-anchored hearing aids. STUDY DESIGN Retrospective cohort study. SETTING Tertiary academic otology-neurotology practice. PATIENTS Patients with conductive or mixed hearing losses meeting criteria to receive active transcutaneous bone-anchored hearing aids. INTERVENTIONS Implantation with one of two active transcutaneous bone-anchored hearing aids. OUTCOME MEASURES Operative time, dural exposure and decompression, use of lifts, implant position, ease of use, qualitative patient satisfaction, complication rates. RESULTS Ten patients received Implant 1 and 11 patients received Implant 2. The most common underlying etiologies of hearing loss were chronic suppurative otitis media in 33.3%, atresia/microtia in 23.8%, and cholesteatoma in 23.8%. Average operative times were 99.3 minutes for Implant 1 and 80.9 minutes for Implant 2 ( p = 0.263). Implant 1 required lifts in 60%, dural exposure in 50%, and dural compression in 30%. Overall, placement was difficult in 47.6% of cases. There were no intraoperative complications. There were higher rates of issues with sound quality (27.3% versus 0.0%, p = 0.123) and poor cosmesis (36.4% versus 10.0%, p = 0.360) with Implant 2. Functional gain was not recorded, but all patients derived qualitative benefit from their implant. Three patients had local wound complications that self-resolved or were treated with antibiotics. One patient implanted at an outside institution required explant because of multiple infections. CONCLUSIONS There were no statistically significant differences in outcomes comparing Implants 1 and 2; however, Implant 2 had much higher rates of issues with audio quality and poor cosmesis. Placing Implant 1 often required special techniques.
Collapse
Affiliation(s)
- Zachary G Schwam
- Department of Otolaryngology-Head and Neck Surgery, Icahn School of Medicine at Mount Sinai, New York, New York
| | | | | | | | | | | | | |
Collapse
|
7
|
Nie Y, Sang J, Zheng C, Xu J, Zhang F, Li X. An objective bone conduction verification tool using a piezoelectric thin-film force transducer. Front Neurosci 2022; 16:1068682. [DOI: 10.3389/fnins.2022.1068682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 10/31/2022] [Indexed: 11/18/2022] Open
Abstract
All hearing aid fittings should be validated with appropriate outcome measurements, whereas there is a lack of well-designed objective verification methods for bone conduction (BC) hearing aids, compared to the real-ear measurement for air conduction hearing aids. This study aims to develop a new objective verification method for BC hearing aids by placing a piezoelectric thin-film force transducer between the BC transducer and the stimulation position. The newly proposed method was compared with the ear canal method and the artificial mastoid method through audibility estimation. The audibility estimation adopted the responses from the transducers that correspond to the individual BC hearing thresholds and three different input levels of pink noise. Twenty hearing-impaired (HI) subjects without prior experience with hearing aids were recruited for this study. The measurement and analysis results showed that the force transducer and ear canal methods almost yielded consistent results, while the artificial mastoid method exhibited significant differences from these two methods. The proposed force transducer method showed a lower noise level and was less affected by the sound field signal when compared with other methods. This indicates that it is promising to utilize a piezoelectric thin-film force transducer as an in-situ objective measurement method of BC stimulation.
Collapse
|
8
|
Casazza GC, Kesser BW. Modern Advances in Bone Conduction–Hearing Devices. CURRENT OTORHINOLARYNGOLOGY REPORTS 2022. [DOI: 10.1007/s40136-022-00430-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
9
|
Rauch AK, Wesarg T, Aschendorff A, Speck I, Arndt S. Long-term data of the new transcutaneous partially implantable bone conduction hearing system Osia®. Eur Arch Otorhinolaryngol 2022; 279:4279-4288. [PMID: 34792628 PMCID: PMC9363475 DOI: 10.1007/s00405-021-07167-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Accepted: 11/01/2021] [Indexed: 01/07/2023]
Abstract
PURPOSE The new active transcutaneous partially implantable osseointegrated system Cochlear™ Osia® System is indicated in case of conductive or mixed hearing loss (CHL/MHL) with a maximum average bone conduction hearing loss of 55 dB, or in single-sided deafness (SSD). The implant directly stimulates the bone via a piezoelectric transducer and is directed by an external sound processor. We conducted a monocentric retrospective longitudinal within-subject clinical study at our tertiary academic referral center. The aim was to investigate long-term data (2017-2021) on audiological outcomes and hearing-related quality of life for the Osia system. METHODS Between 2017 and 2020, 22 adults (18: CHL/MHL; 3: SSD) were implanted with the Osia100 implant; seven received bilateral implants. As of 10/2020, the sound processor was upgraded to Osia 2. RESULTS Mean Osia system use by 04/2021 was 30.9 ± 8.6 months (range 17-40 months). Unaided bone conduction thresholds were unchanged postoperatively. One patient had to be explanted because of prolonged wound infection. Aided hearing thresholds were significantly lower compared to the unaided thresholds preoperatively, along with a marked increase in speech recognition in quiet. Speech processor upgrade resulted in a stable benefit. Patients with CHL/MHL and SSD showed a similar improvement in self-rated hearing performance revealed by SSQ, APHAB, and HUI questionnaires. CONCLUSION The Osia system is a safe, effective and sustainable option for treatment of conductive and mixed hearing loss or single-sided deafness.
Collapse
Affiliation(s)
- Ann-Kathrin Rauch
- Department of Oto-Rhino-Laryngology, Medical Center, University of Freiburg, Killianstr. 5, 79106, Freiburg, Germany.
| | - Thomas Wesarg
- Department of Oto-Rhino-Laryngology, Medical Center, University of Freiburg, Killianstr. 5, 79106, Freiburg, Germany
| | - Antje Aschendorff
- Department of Oto-Rhino-Laryngology, Medical Center, University of Freiburg, Killianstr. 5, 79106, Freiburg, Germany
| | - Iva Speck
- Department of Oto-Rhino-Laryngology, Medical Center, University of Freiburg, Killianstr. 5, 79106, Freiburg, Germany
| | - Susan Arndt
- Department of Oto-Rhino-Laryngology, Medical Center, University of Freiburg, Killianstr. 5, 79106, Freiburg, Germany
| |
Collapse
|
10
|
Deep NL, Johnson BJ, Kay-Rivest E, Carlson ML, Friedmann DR, Driscoll CLW, Thomas Roland J, Jethanamest D. Modifications to Implanting the OSIA® 2 Bone Conduction Hearing Implant: How I Do it. Laryngoscope 2022; 132:1850-1854. [PMID: 35616210 DOI: 10.1002/lary.30153] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 03/23/2022] [Accepted: 04/16/2022] [Indexed: 11/06/2022]
Abstract
This "How I Do It" report describes modifications made to the OSIA bone conduction hearing implant surgery in order to reduce wound complications. Laryngoscope, 2022.
Collapse
Affiliation(s)
- Nicholas L Deep
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Phoenix, Arizona, U.S.A
| | - Brian J Johnson
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota, U.S.A
| | - Emily Kay-Rivest
- Department of Otolaryngology-Head and Neck Surgery, NYU Langone Health, New York, New York, U.S.A
| | - Matthew L Carlson
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota, U.S.A
| | - David R Friedmann
- Department of Otolaryngology-Head and Neck Surgery, NYU Langone Health, New York, New York, U.S.A
| | - Colin L W Driscoll
- Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota, U.S.A
| | - J Thomas Roland
- Department of Otolaryngology-Head and Neck Surgery, NYU Langone Health, New York, New York, U.S.A
| | - Daniel Jethanamest
- Department of Otolaryngology-Head and Neck Surgery, NYU Langone Health, New York, New York, U.S.A
| |
Collapse
|
11
|
Siegel L, Araslanova R, Stepniak C, Zimmerman K, Agrawal SK. Achondroplasia and severe sensorineural hearing loss: The role of active bone conduction implants. Cochlear Implants Int 2022; 23:291-299. [DOI: 10.1080/14670100.2022.2045073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Lauren Siegel
- Department of Otolaryngology-Head and Neck Surgery, Schulich School of Medicine and Dentistry, Western University, London, Canada
| | - Rakhna Araslanova
- Department of Otolaryngology-Head and Neck Surgery, Schulich School of Medicine and Dentistry, Western University, London, Canada
- Department of Otolaryngology-Head and Neck Surgery, Zucker School of Medicine at Hofstra/Northwell, New York, NY, USA
| | - Camilla Stepniak
- Department of Otolaryngology-Head and Neck Surgery, Schulich School of Medicine and Dentistry, Western University, London, Canada
| | - Kim Zimmerman
- Cochlear Implant Program, London Health Sciences Centre, London, Canada
| | - Sumit K. Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Schulich School of Medicine and Dentistry, Western University, London, Canada
- Cochlear Implant Program, London Health Sciences Centre, London, Canada
- National Centre for Audiology, University of Western Ontario, London, Canada
| |
Collapse
|
12
|
Systematic and audiological indication criteria for bone conduction devices and active middle ear implants. Hear Res 2021; 421:108424. [PMID: 34987018 DOI: 10.1016/j.heares.2021.108424] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 12/02/2021] [Accepted: 12/22/2021] [Indexed: 01/11/2023]
Abstract
Certain patients with conductive or mixed hearing loss can benefit from bone-conduction hearing devices or active middle ear implants. Available devices differ in coupling site, energy transfer from the sound processor to the implant, and the active or passive actuator technology. The audiological benefit of those devices depends on the maximum stable power output and the noise floor of the device, the degree and expected stability of the sensorineural hearing loss and the coupling efficiency with the aim on achieving a minumum of 30-35 dB effective dynamic range. The choice of the device is often a trade-off between the optimal audiological solution with respect to the hearing loss, technical device-related parameters and the expected coupling efficiency, the optimal surgical solution with respect to patho-anatomical aspects, device dimensions and the coupling site, invasiveness or surgical risks, and other patient factors with respect to the patients' wish and expectations, social aspects, device usability and connectivity. This review article lists all currently available implantable and conventional bone-conduction hearing devices and active middle ear implants with respect to technical features like maximum power output, market availability, and the expected effective output dynamic range.
Collapse
|