1
|
Sayad R, Elsaeidy AS, Anis AM, Atef M, Hawash EA, Saad HA, Hamad KAA, Kohaf NA. Safety considerations and risk mitigation strategies for ketamine use: a comprehensive review. Ann Med Surg (Lond) 2025; 87:2829-2837. [PMID: 40337391 PMCID: PMC12055169 DOI: 10.1097/ms9.0000000000003232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2024] [Accepted: 03/20/2025] [Indexed: 05/09/2025] Open
Abstract
Ketamine, a dissociative anesthetic, has gained widespread use in various medical contexts, including anesthesia, pain management, and treatment-resistant depression. Despite its therapeutic potential, concerns regarding its safety profile have prompted ongoing research and regulatory guidance. This comprehensive literature review explores the current safety considerations of ketamine, summarizing its adverse effects, particularly on cardiovascular, neuropsychiatric, and dependency effects. Evidence-based guidelines for its administration, dosing, and monitoring are discussed, emphasizing the importance of risk-benefit assessments in clinical practice. The review also delves into current guidelines and proposes future directions for ketamine research and clinical implementation, including enhanced safety protocols, long-term patient outcomes, and the development of individualized safe dosing protocols.
Collapse
Affiliation(s)
- Reem Sayad
- Faculty of Medicine, Assiut University, Assiut, Egypt
| | | | - Amna M. Anis
- College of Medicine, Alfaisal University, Riyadh, Saudi Arabia
| | - Mohamed Atef
- Faculty of Medicine, Assiut University, Assiut, Egypt
| | | | - Hager Adel Saad
- Faculty of Pharmacy and Biotechnology, German University in Cairo (GUC), New Cairo, Egypt
| | | | - Neveen A. Kohaf
- Department of Clinical Pharmacy, Faculty of Pharmacy (Girls), Al-Azhar University, Cairo, Egypt
- Department of Clinical Pharmacy, Faculty of Clinical Pharmacy, Al Baha University, Al Baha, Saudi Arabia
| |
Collapse
|
2
|
吴 文, 戎 惠, 程 锐, 杨 洋, 沈 飞. [Risk factors for initial non-invasive ventilation failure in very low birth weight infants with gestational age <32 weeks: a multicenter retrospective study]. ZHONGGUO DANG DAI ER KE ZA ZHI = CHINESE JOURNAL OF CONTEMPORARY PEDIATRICS 2024; 26:907-913. [PMID: 39267504 PMCID: PMC11404468 DOI: 10.7499/j.issn.1008-8830.2404166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Accepted: 08/05/2024] [Indexed: 09/17/2024]
Abstract
OBJECTIVES To investigate the risk factors and adverse prognosis associated with initial non-invasive ventilation (NIV) failure in very low birth weight infants (VLBWI) with gestational age <32 weeks. METHODS A retrospective collection of clinical data from preterm infants admitted to the neonatal intensive care unit (NICU) in 28 tertiary hospitals in Jiangsu Province from January 2019 to December 2021 was conducted. Based on the outcomes of initial NIV, the infants were divided into a successful group and a failure group to analyze the risk factors for NIV failure and adverse prognosis. RESULTS A total of 817 infants were included, with 453 males (55.4%) and 139 failures (17.0%). The failure group had lower gestational age, birth weight, and 1-minute and 5-minute Apgar scores compared to the successful group (P<0.05). The failure group also had a higher proportion of respiratory distress syndrome (RDS) diagnosed upon NICU admission, higher maximum positive end-expiratory pressure during NIV, and higher percentages of reaching the required maximum fraction of inspired oxygen (FiO2) ≥30%, ≥35%, and ≥40% throughout the initial NIV process compared to the successful group (P<0.05). Gestational age (OR=0.671, 95%CI: 0.581-0.772), RDS (OR=1.955, 95%CI: 1.181-3.366), and FiO2 ≥30% (OR=2.053, 95%CI: 1.106-4.044) were identified as risk factors for initial NIV failure in these infants with gestational age <32 weeks (P<0.05). The failure group had higher incidences of complications such as pulmonary infections, pneumothorax, retinopathy of prematurity, moderate to severe bronchopulmonary dysplasia, and severe intraventricular hemorrhage during hospitalization, as well as longer hospital stays and higher total costs compared to the successful group (P<0.05). CONCLUSIONS Smaller gestational age, a diagnosis of RDS in the NICU, and achieving a maximum FiO2 ≥30% during the initial NIV process are risk factors for initial NIV failure in infants with gestational age <32 weeks. Initial NIV failure significantly increases the risk of adverse outcomes in this population.
Collapse
|
3
|
Göktürk G, Sarıalioğlu A. Effect of white noise during nasal continuous positive airway pressure application on newborn's pain and stress levels, physiological parameters, and crying durations: A randomized controlled study. J Pediatr Nurs 2024; 78:e330-e337. [PMID: 39060170 DOI: 10.1016/j.pedn.2024.07.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 07/21/2024] [Accepted: 07/21/2024] [Indexed: 07/28/2024]
Abstract
PURPOSE The study was conducted to determine the effects of white noise during nasal continuous positive airway pressure (CPAP) application on the newborn's pain and stress levels, physiological parameters, and crying durations. DESIGN AND METHODS The study used a randomized, controlled experimental design. The study was completed with 80 newborns (40 in the intervention group and 40 in the control group). The Newborn Descriptive Data Form, ALPS Newborn Pain and Stress Assessment Scale, and Follow-up Form were used to collect the study data. Routine nasal CPAP application was performed to newborns in the control group. White noise was played to newborns in the intervention group before, during, and after the nasal CPAP application. The study was approved by an ethics committee. RESULTS It was found that the newborn's pain and stress levels of the intervention group were lower than the control group before, during, and after the nasal CPAP application (p < 0.05). Before nasal CPAP application, the intervention group's SpO2 average was lower than that of the control group (p < 0.01). During nasal CPAP application, the intervention group's heart rate, SpO2, and crying duration averages were found to be lower than the control group (p < 0.05). After nasal CPAP application, the intervention group's crying duration average was lower than the control group (p < 0.01). CONCLUSIONS It was found that white noise before, during, and after the nasal CPAP application reduced newborns' pain and stress levels. PRACTICE IMPLICATION It is recommended that white noise be used as an easily applicable, economical, safe, and non-pharmacological method to reduce the pain and stress caused by nasal CPAP application in newborns. CLINICAL TRIALS REGISTRATION The study was registered at Clinical-Trials.gov (NCT05440669).
Collapse
Affiliation(s)
- Gülistan Göktürk
- Department of Child Health and Diseases Nursing, Şanlıurfa Training and Research Hospital, Turkey
| | - Arzu Sarıalioğlu
- Department of Child Health and Diseases Nursing, Atatürk University, Erzurum, Turkey.
| |
Collapse
|
4
|
Roehr CC, Farley HJ, Mahmoud RA, Ojha S. Non-Invasive Ventilatory Support in Preterm Neonates in the Delivery Room and the Neonatal Intensive Care Unit: A Short Narrative Review of What We Know in 2024. Neonatology 2024; 121:576-583. [PMID: 39173610 PMCID: PMC11446298 DOI: 10.1159/000540601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Accepted: 07/22/2024] [Indexed: 08/24/2024]
Abstract
BACKGROUND Guidelines recommend non-invasive ventilatory (NIV) support as first-line respiratory support mode in preterm infants as NIV is superior to intubation and mechanical ventilation in preventing death or bronchopulmonary dysplasia. However, with an ever-expanding variety of NIV modes available, there is much debate about which NIV modality should ideally be used, how, and when. The aims of this work were to summarise the evidence on different NIV modalities for both primary and secondary respiratory support: nCPAP, nasal high-flow therapy (nHFT), and nasal intermittent positive airway pressure ventilation (nIPPV), bi-level positive airway pressure (BiPAP), nasal high-frequency oscillatory ventilation (nHFOV), and nasally applied, non-invasive neurally adjusted ventilatory assist (NIV-NAVA) modes, with particular focus on their use in preterm infants. SUMMARY This is a narrative review with reference to published guidelines by European Consensus Guidelines on the Management of Respiratory Distress Syndrome: 2022 Update. nCPAP is currently the most commonly used primary and secondary NIV modality for premature infants. However, there is increasing evidence on the superiority of nIPPV over nCPAP. No beneficial effect was found for BiPAP over nCPAP. For the use of nHFT, nHFOV, and NIV-NAVA, more studies are needed to establish their place in neonatal respiratory care. KEY MESSAGES The superiority of nIPPV over nCPAP needs to be confirmed by contemporaneous trials comparing nCPAP to nIPPV at comparable mean airway pressures. Future trials should study NIV modalities in preterm infants with comparable respiratory pathology and indications, at comparable pressure settings and with different modes of synchronisation. Importantly, future trials should not exclude infants of the smallest gestational ages.
Collapse
Affiliation(s)
- Charles C Roehr
- National Perinatal Epidemiology Unit, Oxford Population Health, University of Oxford, Oxford, UK,
- Faculty of Health Sciences, University of Bristol, Bristol, UK,
- Newborn Care, Southmead Hospital, North Bristol Trust, Bristol, UK,
| | - Hannah J Farley
- National Perinatal Epidemiology Unit, Oxford Population Health, University of Oxford, Oxford, UK
| | - Ramadan A Mahmoud
- Department of Pediatrics, Sohag Faculty of Medicine, Sohag University, Sohag, Egypt
| | - Shalini Ojha
- Centre for Perinatal Research, School of Medicine, University of Nottingham, Nottingham, UK
- Neonatal Unit, University Hospitals of Derby and Burton NHS Foundation Trust, Derby, UK
| |
Collapse
|
5
|
Wang R, Yang H, Jiang J, Lin Z, Zheng Q, Yu W, Fan S, Liu L. Noninvasive pressure-strain loop quantitative assessment of left ventricular function in anemic preterm infants with different modes of respiratory support. Int J Cardiovasc Imaging 2024; 40:1535-1542. [PMID: 38833045 PMCID: PMC11258163 DOI: 10.1007/s10554-024-03138-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Accepted: 05/13/2024] [Indexed: 06/06/2024]
Abstract
To investigate noninvasive pressure-strain loop (PSL) combined with two-dimensional speck tracking imaging and left ventricular pressure measurement in the evaluation of cardiac function changes in anemia of prematurity (AOP) with different modes of respiratory support, and to explore its value in detecting subclinical myocardial injury in preterm infants. This retrospective study included 79 preterm infants with anemia, according to different modes of respiratory support, who were divided into invasive respiratory support group (39 cases) and noninvasive respiratory support group (40 cases). A control group of 40 nonanemic preterm infants with matched age, sex, and gestational age were also included. Complete echocardiography was performed for each included infant. There are PSL parameters that used to evaluate cardiac function, including global longitudinal strain (GLS), global work index (GWI), global constructive work (GCW), global wasted work (GWW), and global work efficiency (GWE) among the three groups were compared. Compared with the control group, the value of GWI, GCW, and GWE were significantly lower and GWW was higher in the AOP groups (P < 0.05), and GWI, GCW and GWE were much significantly lower in the invasive respiratory support group than in the noninvasive respiratory support group (P < 0.05). There was no significant difference in GLS among the three groups (P > 0.05). Noninvasive PSL analysis can quantitatively assess myocardial work in AOP with different respiratory support, which is more sensitive than other conventional echocardiographic indices. This technique may provide a new method for monitoring subclinical myocardial injury with AOP.
Collapse
MESH Headings
- Humans
- Retrospective Studies
- Infant, Newborn
- Female
- Male
- Infant, Premature
- Predictive Value of Tests
- Ventricular Function, Left
- Gestational Age
- Ventricular Pressure
- Anemia/physiopathology
- Anemia/diagnosis
- Anemia/etiology
- Reproducibility of Results
- Infant, Premature, Diseases/physiopathology
- Infant, Premature, Diseases/diagnostic imaging
- Infant, Premature, Diseases/therapy
- Respiration, Artificial
- Noninvasive Ventilation
- Echocardiography
Collapse
Affiliation(s)
- Ruijie Wang
- Department of Ultrasound, Shenzhen Children's Hospital, Shenzhen, China
| | - Hui Yang
- Department of Neonatal Intensive Care Unit, Shenzhen Children's Hospital, Shenzhen, China
| | - Jingbo Jiang
- Department of Neonatal Intensive Care Unit, Shenzhen Children's Hospital, Shenzhen, China
| | - Zhou Lin
- Department of Ultrasound, Shenzhen Children's Hospital, Shenzhen, China
| | - Qiuying Zheng
- Department of Ultrasound, Shenzhen Children's Hospital, Shenzhen, China
| | - Wei Yu
- Department of Ultrasound, Shenzhen Children's Hospital, Shenzhen, China
| | - Shumin Fan
- Department of Ultrasound, Shenzhen Children's Hospital, Shenzhen, China
| | - Lei Liu
- Department of Ultrasound, Shenzhen Children's Hospital, Shenzhen, China.
| |
Collapse
|
6
|
Prakash R, De Paoli AG, Davis PG, Oddie SJ, McGuire W. Bubble devices versus other pressure sources for nasal continuous positive airway pressure in preterm infants. Cochrane Database Syst Rev 2023; 3:CD015130. [PMID: 37009665 PMCID: PMC10064833 DOI: 10.1002/14651858.cd015130] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
Abstract
BACKGROUND Several types of pressure sources, including underwater bubble devices, mechanical ventilators, and the Infant Flow Driver, are used for providing continuous positive airway pressure (CPAP) to preterm infants with respiratory distress. It is unclear whether the use of bubble CPAP versus other pressure sources is associated with lower rates of CPAP treatment failure, or mortality and other morbidity. OBJECTIVES: To assess the benefits and harms of bubble CPAP versus other pressure sources (mechanical ventilators or Infant Flow Driver) for reducing treatment failure and associated morbidity and mortality in newborn preterm infants with or at risk of respiratory distress. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2023, Issue 1); MEDLINE (1946 to 6 January 2023), Embase (1974 to 6 January 2023), Maternity & Infant Care Database (1971 to 6 January 2023), and the Cumulative Index to Nursing and Allied Health Literature (1982 to 6 January 2023). We searched clinical trials databases and the reference lists of retrieved articles. SELECTION CRITERIA We included randomised controlled trials comparing bubble CPAP with other pressure sources (mechanical ventilators or Infant Flow Driver) for the delivery of nasal CPAP to preterm infants. DATA COLLECTION AND ANALYSIS We used standard Cochrane methods. Two review authors separately evaluated trial quality, extracted data, and synthesised effect estimates using risk ratio (RR), risk difference (RD), and mean difference. We used the GRADE approach to assess the certainty of the evidence for effects on treatment failure, all-cause mortality, neurodevelopmental impairment, pneumothorax, moderate-severe nasal trauma, and bronchopulmonary dysplasia. MAIN RESULTS We included 15 trials involving a total of 1437 infants. All trials were small (median number of participants 88). The methods used to generate the randomisation sequence and ensure allocation concealment were unclear in about half of the trial reports. Lack of measures to blind caregivers or investigators was a potential source of bias in all of the included trials. The trials took place during the past 25 years in care facilities internationally, predominantly in India (five trials) and Iran (four trials). The studied pressure sources were commercially available bubble CPAP devices versus a variety of mechanical ventilator (11 trials) or Infant Flow Driver (4 trials) devices. Meta-analyses suggest that the use of bubble CPAP compared with mechanical ventilator or Infant Flow Driver CPAP may reduce the rate of treatment failure (RR 0.76, 95% confidence interval (CI) 0.60 to 0.95; (I² = 31%); RD -0.05, 95% CI -0.10 to -0.01; number needed to treat for an additional beneficial outcome 20, 95% CI 10 to 100; 13 trials, 1230 infants; low certainty evidence). The type of pressure source may not affect mortality prior to hospital discharge (RR 0.93, 95% CI 0.64 to 1.36 (I² = 0%); RD -0.01, 95% CI -0.04 to 0.02; 10 trials, 1189 infants; low certainty evidence). No data were available on neurodevelopmental impairment. Meta-analysis suggests that the pressure source may not affect the risk of pneumothorax (RR 0.73, 95% CI 0.40 to 1.34 (I² = 0%); RD -0.01, 95% CI -0.03 to 0.01; 14 trials, 1340 infants; low certainty evidence). Bubble CPAP likely increases the risk of moderate-severe nasal injury (RR 2.29, 95% CI 1.37 to 3.82 (I² = 17%); RD 0.07, 95% CI 0.03 to 0.11; number needed to treat for an additional harmful outcome 14, 95% CI 9 to 33; 8 trials, 753 infants; moderate certainty evidence). The pressure source may not affect the risk of bronchopulmonary dysplasia (RR 0.76, 95% CI 0.53 to 1.10 (I² = 0%); RD -0.04, 95% CI -0.09 to 0.01; 7 trials, 603 infants; low certainty evidence). AUTHORS' CONCLUSIONS: Given the low level of certainty about the effects of bubble CPAP versus other pressure sources on the risk of treatment failure and most associated morbidity and mortality for preterm infants, further large, high-quality trials are needed to provide evidence of sufficient validity and applicability to inform context- and setting-relevant policy and practice.
Collapse
Affiliation(s)
- Raj Prakash
- Paediatrics, York and Scarborough Teaching Hospitals NHS Trust, York, UK
| | | | - Peter G Davis
- Newborn Research Centre and Neonatal Services, The Royal Women's Hospital, Melbourne, Australia
| | - Sam J Oddie
- Bradford Neonatology, Bradford Teaching Hospitals NHS Foundation Trust, Bradford, UK
| | - William McGuire
- Centre for Reviews and Dissemination, University of York, York, UK
| |
Collapse
|
7
|
Boix H, Fernández C, Serrano Martín MDM, Arruza L, Concheiro A, Gimeno A, Sánchez A, Rite S, Jiménez F, Méndez P, Agüera JJ. Failure of early non-invasive ventilation in preterm infants with respiratory distress syndrome in current care practice in Spanish level-III neonatal intensive care units - a prospective observational study. Front Pediatr 2023; 11:1098971. [PMID: 36896404 PMCID: PMC9989254 DOI: 10.3389/fped.2023.1098971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 01/30/2023] [Indexed: 02/25/2023] Open
Abstract
Introduction Despite advances in respiratory distress syndrome (RDS) management over the past decade, non-invasive ventilation (NIV) failure is frequent and associated with adverse outcomes. There are insufficient data on the failure of different NIV strategies currently used in clinical practice in preterm infants. Methods This was a prospective, multicenter, observational study of very preterm infants [gestational age (GA) <32 weeks] admitted to the neonatal intensive care unit for RDS that required NIV from the first 30 min after birth. The primary outcome was the incidence of NIV failure, defined as the need for mechanical ventilation for <72 h of life. Secondary outcomes were risk factors associated with NIV failure and complication rates. Results The study included 173 preterm infants with a median GA of 28 (IQR 27-30) weeks and a median birth weight of 1,100 (IQR 800-1,333) g. The incidence of NIV failure was 15.6%. In the multivariate analysis, lower GA (OR, 0.728; 95% CI, 0.576-0.920) independently increased the risk of NIV failure. Compared to NIV success, NIV failure was associated with higher rates of unfavorable outcomes, including pneumothorax, intraventricular hemorrhage, periventricular leukomalacia, pulmonary hemorrhage, and a combined outcome of moderate-to-severe bronchopulmonary dysplasia or death. Conclusion NIV failure occurred in 15.6% of the preterm neonates and was associated with adverse outcomes. The use of LISA and newer NIV modalities most likely accounts for the reduced failure rate. Gestational age remains the best predictor of NIV failure and is more reliable than the fraction of inspired oxygen during the first hour of life.
Collapse
Affiliation(s)
- Hector Boix
- Division of Neonatology, Hospital Universitario Dexeus, Barcelona, Spain
| | - Cristina Fernández
- Department of Neonatology, Hospital Universitario Vall d'Hebron, Barcelona, Spain
| | | | - Luis Arruza
- Department of Neonatology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - Ana Concheiro
- Department of Neonatology, Álvaro Cunqueiro University Hospital, Vigo, Spain
| | - Ana Gimeno
- Division of Neonatology, University and Polytechnic Hospital La Fe, Valencia, Spain
| | - Ana Sánchez
- Department of Neonatology, Hospital Universitario La Paz, Madrid, Spain
| | - Segundo Rite
- Division of Neonatology, Hospital Universitario Miguel Servet, Zaragoza, Spain
| | - Francisco Jiménez
- Department of Neonatology and Neonatal Intensive Care Unit, Hospital Infantil Universitario Virgen del Rocio, Seville, Spain
| | - Paula Méndez
- Division of Paediatrics, Section of Neonatology, Hospital Universitario Puerta del Mar, Cadiz, Spain
| | - Juan José Agüera
- Department of Paediatrics, Neonatology Section, Virgen de la Arrixaca, University Hospital, Murcia, Spain
| | | |
Collapse
|
8
|
Prakash R, De Paoli AG, Oddie SJ, Davis PG, McGuire W. Masks versus prongs as interfaces for nasal continuous positive airway pressure in preterm infants. Cochrane Database Syst Rev 2022; 11:CD015129. [PMID: 36374241 PMCID: PMC9662142 DOI: 10.1002/14651858.cd015129] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Nasal masks and nasal prongs are used as interfaces for providing continuous positive airway pressure (CPAP) for preterm infants with or at risk of respiratory distress, either as primary support after birth or as ongoing support after endotracheal extubation from mechanical ventilation. It is unclear which type of interface is associated with lower rates of CPAP treatment failure, nasal trauma, or mortality and other morbidity. OBJECTIVES To assess the benefits and harms of nasal masks versus nasal prongs for reducing CPAP treatment failure, nasal trauma, or mortality and other morbidity in newborn preterm infants with or at risk of respiratory distress. SEARCH METHODS We used standard, extensive Cochrane search methods. The latest search date was October 2021. SELECTION CRITERIA We included randomised controlled trials comparing masks versus prongs as interfaces for delivery of nasal CPAP in newborn preterm infants (less than 37 weeks' gestation) with or at risk of respiratory distress. DATA COLLECTION AND ANALYSIS We used standard Cochrane methods. Our primary outcomes were 1. treatment failure, 2. all-cause mortality, and 3. neurodevelopmental impairment. Our secondary outcomes were 4. pneumothorax, 5. moderate-severe nasal trauma, 6. bronchopulmonary dysplasia, 7. duration of CPAP use, 8. duration of oxygen supplementation, 9. duration of hospitalisation, 10. patent ductus arteriosus receiving medical or surgical treatment, 11. necrotising enterocolitis, 12. severe intraventricular haemorrhage, and 13. severe retinopathy of prematurity. We used the GRADE approach to assess the certainty of the evidence. MAIN RESULTS We included 12 trials with 1604 infants. All trials were small (median number of participants 118). The trials occurred after 2001 in care facilities internationally, predominantly in India (eight trials). Most participants were preterm infants of 26 to 34 weeks' gestation who received nasal CPAP as the primary form of respiratory support after birth. The studied interfaces included commonly used commercially available masks and prongs. Lack of measures to blind caregivers or investigators was a potential source of performance and detection bias in all the trials. Meta-analyses suggested that use of masks compared with prongs may reduce CPAP treatment failure (risk ratio (RR) 0.72, 95% confidence interval (CI) 0.58 to 0.90; 8 trials, 919 infants; low certainty). The type of interface may not affect mortality prior to hospital discharge (RR 0.83, 95% CI 0.56 to 1.22; 7 trials, 814 infants; low certainty). There are no data on neurodevelopmental impairment. Meta-analyses suggest that the choice of interface may result in little or no difference in the risk of pneumothorax (RR 0.93, 95% CI 0.45 to 1.93; 5 trials, 625 infants; low certainty). Use of masks rather than prongs may reduce the risk of moderate-severe nasal injury (RR 0.55, 95% CI 0.44 to 0.71; 10 trials, 1058 infants; low certainty). The evidence is very uncertain about the effect on bronchopulmonary dysplasia (RR 0.69, 95% CI 0.46 to 1.03; 7 trials, 843 infants; very low certainty). AUTHORS' CONCLUSIONS The available trial data provide low-certainty evidence that use of masks compared with prongs as the nasal CPAP interface may reduce treatment failure and nasal injury, and may have little or no effect on mortality or the risk of pneumothorax in newborn preterm infants with or at risk of respiratory distress. The effect on bronchopulmonary dysplasia is very uncertain. Large, high-quality trials would be needed to provide evidence of sufficient validity and applicability to inform policy and practice.
Collapse
Affiliation(s)
- Raj Prakash
- York and Scarborough Teaching Hospitals, NHS Trust, York, UK
| | | | - Sam J Oddie
- Bradford Neonatology, Bradford Teaching Hospitals NHS Foundation Trust, Bradford, UK
| | - Peter G Davis
- Newborn Research Centre and Neonatal Services, The Royal Women's Hospital, Melbourne, Australia
- Murdoch Children's Research Institute, Melbourne, Australia
- Department of Obstetrics and Gynecology, University of Melbourne, Melbourne, Australia
| | - William McGuire
- Centre for Reviews and Dissemination, University of York, York, UK
| |
Collapse
|
9
|
Schulzke SM, Stoecklin B. Update on ventilatory management of extremely preterm infants-A Neonatal Intensive Care Unit perspective. Paediatr Anaesth 2022; 32:363-371. [PMID: 34878697 PMCID: PMC9300007 DOI: 10.1111/pan.14369] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 12/03/2021] [Accepted: 12/06/2021] [Indexed: 12/11/2022]
Abstract
Extremely preterm infants commonly suffer from respiratory distress syndrome. Ventilatory management of these infants starts from birth and includes decisions such as timing of respiratory support in relation to umbilical cord management, oxygenation targets, and options of positive pressure support. The approach of early intubation and surfactant administration through an endotracheal tube has been challenged in recent years by primary noninvasive respiratory support and newer methods of surfactant administration via thin catheters. Available data comparing the thin catheter method to endotracheal tube and delayed extubation in extremely preterm infants born before 28 weeks of gestation did not show differences in survival free of bronchopulmonary dysplasia. Data from numerous randomized trials comparing conventional ventilation with high-frequency oscillatory ventilation did not show differences in meaningful outcomes. Among conventional modes of ventilation, there is good evidence to favor volume-targeted ventilation over pressure-limited ventilation. The former reduces the combined risk of bronchopulmonary dysplasia or death and several important secondary outcomes without an increase in adverse events. There are no evidence-based guidelines to set positive end-expiratory pressure in ventilated preterm infants. Recent research suggests that the forced oscillation technique may help to find the lowest positive end-expiratory pressure at which lung recruitment is optimal. Benefits and risks of the various modes of noninvasive ventilation depend on the clinical setting, degree of prematurity, severity of lung disease, and competency of staff in treating associated complications. Respiratory care after discharge includes home oxygen therapy, lung function monitoring, weaning from medication started in the neonatal unit, and treatment of asthma-like symptoms.
Collapse
Affiliation(s)
- Sven M. Schulzke
- Department of NeonatologyUniversity Children's Hospital Basel UKBBBaselSwitzerland,Faculty of MedicineUniversity of BaselBaselSwitzerland
| | - Benjamin Stoecklin
- Department of NeonatologyUniversity Children's Hospital Basel UKBBBaselSwitzerland
| |
Collapse
|
10
|
Halliday HL, Speer CP. Sharing Progress in Neonatology (SPIN): Oxygen and Surfactant, Optimal Ventilation, Pulmonary Hypertension, Diagnostic Procedures, and Definition of Bronchopulmonary Dysplasia. Neonatology 2021; 118:207-210. [PMID: 33979805 DOI: 10.1159/000516039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Accepted: 03/22/2021] [Indexed: 11/19/2022]
|