1
|
Clinical and Radiographic Outcomes of Zirconia Dental Implants-A Clinical Case Series Study. MATERIALS 2022; 15:ma15072437. [PMID: 35407772 PMCID: PMC8999721 DOI: 10.3390/ma15072437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/22/2022] [Accepted: 03/23/2022] [Indexed: 11/17/2022]
Abstract
The purpose of this clinical series was to evaluate the clinical and radiographic outcomes of 20 zirconia dental implants, with a minimum follow-up of two years. Patients with at least one zirconia dental implant were included, with a mean follow-up of 34.05 months. The patient complaints such as pain and foreign body sensation, as well as clinical parameters including peri-implant infections with suppuration, implant mobility, gingival index (GI), modified plaque index (mPI), modified sulcus bleeding index (mBI), probing depth (PD) and radiological distance between the implant shoulder to the closest mesial and distal bone-to-implant contact (BIC), were assessed. All zirconia implants were successfully integrated without any pain or foreign body sensation. No mobility was detected in any of the 20 implants. Clinical examination revealed a mean PD of 2.56 mm and a radiological mean distance between the implant shoulder and the initial site of visible bone-to-implant contact (BIC) of 1.44 mm. In addition, GI, mPI and mBI indicated minimal to no inflammation. Results obtained from this series suggest that one-piece zirconia dental implants achieve good clinical and radiographic outcomes over a mean follow-up of 34 months and may be deemed a good option in patients with favorable bone conditions.
Collapse
|
2
|
A Biocompatible Ultrananocrystalline Diamond (UNCD) Coating for a New Generation of Dental Implants. NANOMATERIALS 2022; 12:nano12050782. [PMID: 35269268 PMCID: PMC8911871 DOI: 10.3390/nano12050782] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/09/2022] [Accepted: 02/17/2022] [Indexed: 02/04/2023]
Abstract
Implant therapy using osseointegratable titanium (Ti) dental implants has revolutionized clinical dental practice and has shown a high rate of success. However, because a metallic implant is in contact with body tissues and fluids in vivo, ions/particles can be released into the biological milieu as a result of corrosion or biotribocorrosion. Ultrananocrystalline diamond (UNCD) coatings possess a synergistic combination of mechanical, tribological, and chemical properties, which makes UNCD highly biocompatible. In addition, because the UNCD coating is made of carbon (C), a component of human DNA, cells, and molecules, it is potentially a highly biocompatible coating for medical implant devices. The aim of the present research was to evaluate tissue response to UNCD-coated titanium micro-implants using a murine model designed to evaluate biocompatibility. Non-coated (n = 10) and UNCD-coated (n = 10) orthodontic Ti micro-implants were placed in the hematopoietic bone marrow of the tibia of male Wistar rats. The animals were euthanized 30 days post implantation. The tibiae were resected, and ground histologic sections were obtained and stained with toluidine blue. Histologically, both groups showed lamellar bone tissue in contact with the implants (osseointegration). No inflammatory or multinucleated giant cells were observed. Histomorphometric evaluation showed no statistically significant differences in the percentage of BIC between groups (C: 53.40 ± 13% vs. UNCD: 58.82 ± 9%, p > 0.05). UNCD showed good biocompatibility properties. Although the percentage of BIC (osseointegration) was similar in UNCD-coated and control Ti micro-implants, the documented tribological properties of UNCD make it a superior implant coating material. Given the current surge in the use of nano-coatings, nanofilms, and nanostructured surfaces to enhance the biocompatibility of biomedical implants, the results of the present study contribute valuable data for the manufacture of UNCD coatings as a new generation of superior dental implants.
Collapse
|
3
|
Salivary Levels of Titanium, Nickel, Vanadium, and Arsenic in Patients Treated with Dental Implants: A Case-Control Study. J Clin Med 2020; 9:jcm9051264. [PMID: 32349296 PMCID: PMC7288178 DOI: 10.3390/jcm9051264] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2020] [Revised: 04/19/2020] [Accepted: 04/23/2020] [Indexed: 12/12/2022] Open
Abstract
Background: Recent articles have hypothesized a possible correlation between dental implants dissolution products and peri-implantitis. The null hypothesis tested in this case-control study was that there would be no differences in salivary concentrations of titanium (Ti), vanadium (V), nickel (Ni) and arsenic (As) ions among patients with dental implants, healthy (Group A) or affected by peri-implantitis (Group B), compared to subjects without implants and/or metallic prosthetic restorations (Group C). Methods: Inductively coupled plasma mass spectrometry was used to analyze saliva samples. One-way repeated-measure analysis of variance (ANOVA) was used to identify statistically significant differences in the salivary level of Ti, V, Ni and As between the three groups. Results: A total of 100 patients were enrolled in the study (42 males and 58 females), distributed in three groups: 50 patients in Group C, 26 patients in Group B and 24 patients Group B. In our study, concentrations of metallic ions were higher in Group A and B, compared to the control group, with the exception of vanadium. However, there were no statistically significant differences (p > 0.05) for metallic ions concentrations between Group A and Group B. Conclusions: Based on our results, there are no differences in titanium or other metals concentrations in saliva of patients with healthy or diseased implants.
Collapse
|
4
|
Noumbissi S, Scarano A, Gupta S. A Literature Review Study on Atomic Ions Dissolution of Titanium and Its Alloys in Implant Dentistry. MATERIALS 2019; 12:ma12030368. [PMID: 30682826 PMCID: PMC6384935 DOI: 10.3390/ma12030368] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Revised: 01/06/2019] [Accepted: 01/21/2019] [Indexed: 02/07/2023]
Abstract
This review of literature paper was done in order to conduct a review of the literature and an assessment of the effects of titanium implant corrosion on peri-implant health and success in the oral environment. This paper evaluates and critically reviews the findings of the multiple in-depth in vivo and in vitro studies that are related to corrosion aspects of the titanium and its alloys. A literature survey was conducted by electronic search in Medline and studies that were published between 1940 and August 2018 were selected. The search terms used were types of corrosion, corrosion of titanium implants, titanium corrosion, metal ion release from the titanium implants, fretting and pitting corrosion, implant corrosion, peri implantitis, and corrosion. Both in vivo and in vitro studies were also included in the review. The search and selection resulted in 64 articles. These articles were divided on the basis of their context to different kinds of corrosion related to titanium dental implants. It is evident that metal ions are released from titanium and titanium alloy dental implants as a result of corrosion. Corrosion of implants is multifactorial, including electrical, chemical, and mechanical factors, which have an effect on the peri-implant tissues and microbiota. The literature surveyed showed that corrosion related to titanium and its alloys has an effect on the health of peri-implant soft and hard tissue and the long term survival of metal dental implants. It can be concluded that presence of the long-term corrosion reaction along with continuous corrosion leads to the release of ions into the peri-implant tissue but also to a disintegration of the implant that contribute to material fatigue and even fracture of the abutments and implant body or both. This combined impact of the corrosion, bacterial activity, chemical reactions, and functional stresses are to be looked at as important factors of implant failure. The findings can be used to explore the possible strategies of research to investigate the biological impact of implant materials.
Collapse
Affiliation(s)
- Sammy Noumbissi
- International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA.
- Department of Medical, Oral and Biotechnological Sciences and CeSi Met, University of Chieti-Pescara, 66100 Chieti, Italy.
- Zirconia Implant Research Group, Silver Spring, MD 20910, USA.
| | - Antonio Scarano
- Department of Medical, Oral and Biotechnological Sciences and CeSi Met, University of Chieti-Pescara, 66100 Chieti, Italy.
- Zirconia Implant Research Group, Silver Spring, MD 20910, USA.
| | - Saurabh Gupta
- International Academy of Ceramic Implantology, Silver Spring, MD 20910, USA.
- Zirconia Implant Research Group, Silver Spring, MD 20910, USA.
- Oral & Maxillofacial Surgeon and Implantologist, Private Practice Dentistry, Bangalore 560042, India.
| |
Collapse
|
5
|
Titanium Ions Promote Exogenous Calcium-Dependent Calcium Influx in Activated Jurkat T Cells: A Possible Mechanism to Explain Its Immunostimulatory Properties. Mediators Inflamm 2018; 2018:3286905. [PMID: 30581368 PMCID: PMC6276418 DOI: 10.1155/2018/3286905] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 06/22/2018] [Accepted: 10/14/2018] [Indexed: 12/22/2022] Open
Abstract
Titanium and its alloys have been widely used in dental and orthopedic implants. Owing to the biotribocorrosion behavior of implants in simulated oral environment, Ti(IV) ions could be released into surrounding tissues. Current studies have found that Ti(IV) ions could affect the biological activities of immune cells in adjacent tissues and subsequently jeopardize the long-term performance of implant prostheses. However, the potential mechanism underlying its immunomodulatory properties remains unclear. Calcium signaling has been confirmed to be involved in regulation of lymphocyte immune function. Therefore, we hypothesize that Ti(IV) ions modulated T cell function through the change of intracellular calcium concentrations. This study is aimed at exploring the role of intracellular calcium responses in the modulatory effect of Ti(IV) ions on unactivated and phytohemagglutinin-activated Jurkat T cells. Here, we confirmed that Ti(IV) ions within a certain concentration range induced CD69 expression on both unactivated and activated T cells in our study. Additionally, the combined stimulation with Ti(IV) ions and PHA increased expression of IL-1β, TNF-α, and RANKL. Furthermore, we found that treatment with Ti(IV) induced a transitory increase in the levels of [Ca2+]i in activated Jurkat cells, dependent on the presence of exogenous calcium. Treatment with different doses of Ti(IV) for 24 h significantly increased the levels of [Ca2+]i in the activated Jurkat cells in a dose-dependent manner, but had little effect in the unactivated cells. Treatment with Ti(IV) did not significantly affect the PLCγ1 activation and inositol-1,4,5-trisphosphate (IP3) secretion in Jurkat cells. Taken together, these data indicated that Ti(IV) enhanced calcium influx during the T cell activation, independent of IP3-mediated intracellular calcium release. Our work provides insights into the mechanism involved in the regulation of lymphocyte behaviors under the effect of Ti(IV) ions, which may help to develop therapeutic strategies for dental implant failures.
Collapse
|
6
|
Mehl C, Kern M, Neumann F, Bähr T, Wiltfang J, Gassling V. Effect of ultraviolet photofunctionalization of dental titanium implants on osseointegration. J Zhejiang Univ Sci B 2018; 19:525-534. [PMID: 29971991 DOI: 10.1631/jzus.b1600505] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The aim of the current study was to evaluate the effect of ultraviolet (UV) photofunctionalization of dental titanium implants with exposure to the oral cavity on osseointegration in an animal model. METHODS Forty-eight titanium implants (Camlog® Conelog® 4.3 mmx9.0 mm) were placed epicrestally into the edentulous jaws of three minipigs and implant stability was assessed by measuring the implant stability quotient (ISQ). Prior to implantation half of the implants were photofunctionalized with intense UV-light. After three months, the implants were exposed and ISQ was measured again. After six months of implant exposure, the minipigs were sacrificed and the harvested specimens were analyzed using histomorphometric, light, and fluorescence microscopy. MAIN RESULTS Forty-two of 48 implants osseointegrated. The overall mean bone-implant contact area (BIC) was (64±22)%. No significant differences were found in BIC or ISQ value (multivariate analysis of variance (MANOVA), P>0.05) between implants with and without exposure to UV photofunctionalization. CONCLUSIONS No significant effects were observed on osseointegration of dental titanium implants nine months after exposure of UV photofunctionalization.
Collapse
Affiliation(s)
- Christian Mehl
- Department of Prosthodontics, Propaedeutics and Dental Materials, Christian-Albrechts University at Kiel, Arnold-Heller-Straße 16, 24105, Kiel, Germany
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, Christian-Albrechts University at Kiel, Arnold-Heller-Straße 16, 24105, Kiel, Germany
| | - Friederike Neumann
- Department of Prosthodontics, Propaedeutics and Dental Materials, Christian-Albrechts University at Kiel, Arnold-Heller-Straße 16, 24105, Kiel, Germany
| | - Telse Bähr
- Private Practice, Lassabeker Weg 3, 24211, Lehmkuhlen, Germany
| | - Jörg Wiltfang
- Department of Oral and Maxillofacial Surgery, Christian-Albrechts University at Kiel, Arnold-Heller-Straße 16, 24105, Kiel, Germany
| | - Volker Gassling
- Department of Oral and Maxillofacial Surgery, Christian-Albrechts University at Kiel, Arnold-Heller-Straße 16, 24105, Kiel, Germany
| |
Collapse
|
7
|
Suárez-López del Amo F, Garaicoa-Pazmiño C, Fretwurst T, Castilho RM, Squarize CH. Dental implants-associated release of titanium particles: A systematic review. Clin Oral Implants Res 2018; 29:1085-1100. [DOI: 10.1111/clr.13372] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 08/16/2018] [Accepted: 08/28/2018] [Indexed: 12/13/2022]
Affiliation(s)
- Fernando Suárez-López del Amo
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Periodontics; University of Oklahoma Health Sciences Center; Oklahoma City Oklahoma
| | - Carlos Garaicoa-Pazmiño
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Periodontics and Oral Medicine; University of Michigan School of Dentistry; Ann Arbor Michigan
| | - Tobias Fretwurst
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Oral and Craniomaxillofacial Surgery, Center for Dental Medicine; University Medical Center Freiburg; Freiburg Germany
| | - Rogerio M. Castilho
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Periodontics and Oral Medicine; University of Michigan School of Dentistry; Ann Arbor Michigan
| | - Cristiane H. Squarize
- Laboratory of Epithelial Biology, Department of Periodontics and Oral Medicine; University of Michigan School; Ann Arbor Michigan
- Department of Periodontics and Oral Medicine; University of Michigan School of Dentistry; Ann Arbor Michigan
| |
Collapse
|
8
|
Safioti LM, Kotsakis GA, Pozhitkov AE, Chung WO, Daubert DM. Increased Levels of Dissolved Titanium Are Associated With Peri-Implantitis - A Cross-Sectional Study. J Periodontol 2016; 88:436-442. [PMID: 27858551 DOI: 10.1902/jop.2016.160524] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND Peri-implantitis represents a disruption of the biocompatible interface between the titanium dioxide layer of the implant surface and the peri-implant tissues. Increasing preclinical data suggest that peri-implantitis microbiota not only triggers an inflammatory immune response but also causes electrochemical alterations of the titanium surfaces, i.e., corrosion, that aggravate this inflammatory response. Thus, it was hypothesized that there is an association between dissolution of titanium from dental implants, which suggests corrosion, and peri-implantitis in humans. The objective of this study is to compare levels of dissolved titanium in submucosal plaque collected from healthy implants and implants with peri-implantitis. METHODS Submucosal plaque from 20 implants with peri-implantitis and 20 healthy implants was collected with sterile curets from 30 participants. Levels of titanium were quantified using inductively coupled plasma mass spectrometry and normalized for mass of bacterial DNA per sample to exclude confounding by varying amounts of plaque per site. Statistical analysis was performed using generalized estimated equations to adjust for clustering of implants per participant. RESULTS Implants with peri-implantitis harbored significantly higher mean levels of titanium (0.85 ± 2.47) versus healthy implants (0.07 ± 0.19) after adjusting for amount of plaque collected per site (P = 0.033). CONCLUSIONS Greater levels of dissolved titanium were detected in submucosal plaque around implants with peri-implantitis compared with healthy implants, indicating an association between titanium dissolution and peri-implantitis. Factors triggering titanium dissolution, as well as the role of titanium corrosion in the peri-implant inflammatory process, warrant further investigation.
Collapse
Affiliation(s)
| | | | | | - Whasun O Chung
- Department of Oral Health Sciences, University of Washington
| | - Diane M Daubert
- Department of Periodontics, University of Washington, Seattle, WA
| |
Collapse
|