1
|
Karvonen J, Lehto S, Lenz C, Beaudoint C, Oyeniran S, Kayser T, Vikman S, Pakarinen S. Minute ventilation sensor-driven rate response as a part of cardiac resynchronization therapy optimization in older patients. J Interv Card Electrophysiol 2024; 67:2017-2027. [PMID: 38914900 PMCID: PMC11711142 DOI: 10.1007/s10840-024-01848-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 06/03/2024] [Indexed: 06/26/2024]
Abstract
BACKGROUND Chronotropic incompetence (CI) is common among elderly cardiac resynchronization therapy pacemaker (CRT-P) patients on optimal medical therapy. This study aimed to evaluate the impact of optimized rate-adaptive pacing utilizing the minute ventilation (MV) sensor on exercise tolerance. METHODS In a prospective, multicenter study, older patients (median age 76 years) with a guideline-based indication for CRT were evaluated following CRT-P implantation. If there was no documented CI, requiring clinically rate-responsive pacing, the device was programmed DDD at pre-discharge. At 1 month, a 6-min walk test (6MWT) was conducted. If the maximum heart rate was < 100 bpm or < 80% of the age-predicted maximum, the response was considered CI. Patients with CI were programmed with DDDR. At 3 months post-implant, the 6MWT was repeated in the correct respective programming mode. In addition, heart rate score (HRSc, defined as the percentage of all sensed and paced atrial events in the single tallest 10 bpm histogram bin) was assessed at 1 and 3 months. RESULTS CI was identified in 46/61 (75%) of patients without prior indication at enrollment. MV sensor-based DDDR mode increased heart rate in CI patients similarly to non-CI patients with intrinsically driven heart rates during 6MWT. Walking distance increased substantially with DDDR (349 ± 132 m vs. 376 ± 128 m at 1 and 3 months, respectively, p < 0.05). Furthermore, DDDR reduced HRSc by 14% (absolute reduction, p < 0.001) in those with more severe CI, i.e., HRSc ≥ 70%. CONCLUSION Exercise tolerance in older CRT-P patients can be further improved by the utilization of an MV sensor.
Collapse
Affiliation(s)
- Jarkko Karvonen
- Department of Cardiology, Helsinki University Hospital Heart and Lung Center, Haartmaninkatu 4, 00029, Helsinki, Finland.
| | - Sanni Lehto
- Department of Cardiology, Helsinki University Hospital Heart and Lung Center, Haartmaninkatu 4, 00029, Helsinki, Finland
| | - Corinna Lenz
- UKB Klinik Für Innere Medizin, Kardiologie, Berlin, Germany
| | - Caroline Beaudoint
- Boston Scientific, Green Square, Lambroekstraat 5D, 1831, Diegem, Belgium
| | - Sola Oyeniran
- Boston Scientific, Green Square, Lambroekstraat 5D, 1831, Diegem, Belgium
| | - Torsten Kayser
- Boston Scientific, Green Square, Lambroekstraat 5D, 1831, Diegem, Belgium
| | - Saila Vikman
- Heart Hospital, Tampere University Hospital, Tampere, Finland
| | - Sami Pakarinen
- Department of Cardiology, Helsinki University Hospital Heart and Lung Center, Haartmaninkatu 4, 00029, Helsinki, Finland
| |
Collapse
|
2
|
Hayashi K, Abe H, Olshansky B, Sharma AD, Jones PW, Wold N, Perschbacher D, Kohno R, Lip GYH, Varma N, Wilkoff BL. High initial heart rate score is an independent predictor of new atrial high-rate episodes in pacemaker patients with sinus node dysfunction. Heart Rhythm 2024; 21:2543-2551. [PMID: 38936446 DOI: 10.1016/j.hrthm.2024.06.046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 06/20/2024] [Accepted: 06/22/2024] [Indexed: 06/29/2024]
Abstract
BACKGROUND Heart rate score (HRSc), the percentage of atrial depolarizations in the largest paced and sensed 10-beats/min histogram bin recorded in cardiac devices, is associated with several adverse outcomes, but it remains uncertain whether HRSc independently predicts atrial high-rate episodes (AHREs) in patients with sinus node dysfunction (SND) undergoing pacemaker (PM) implantation. OBJECTIVE This study aimed to determine whether initial HRSc after PM implantation predicts new-onset AHREs in patients with SND. METHODS Patients had Boston Scientific PMs implanted for SND from 2012 to 2021 at Cleveland Clinic, University of Occupational and Environmental Health, Japan, Kyushu Rosai Hospital, and JCHO Kyushu Hospital. Patients were excluded if they had atrial fibrillation before PM implantation or AHREs within 3 months after implantation. Subsequent AHREs after implantation were evaluated and correlated with HRSc. RESULTS During 48.9 (interquartile range, 25.7-50.4) months, 130 consecutive PM patients (76 ± 10 years; 40% male) had a median initial HRSc of 74% (57%-86%). AHREs defined by >1%, >6 h/d burden, and atrial tachycardia response events >24 hours developed in 27 of 130 (21%), 15 of 130 (12%), and 9 of 130 (7%), respectively. For each definition, patients with HRSc ≥80% had higher occurrence of AHREs than those with HRSc <80% (both P = .008, log-rank test). After adjustment for age, race, comorbidities, left ventricular ejection fraction, left atrial diameter, and cumulative percentage of right atrial and right ventricular pacing, initial HRSc ≥80% (hazard ratio, 3.33; 95% CI, 1.35-8.18; P = .009) and male sex (hazard ratio, 2.59; 95% CI, 1.06-6.33; P = .04) independently predicted AHREs. CONCLUSION HRSc ≥80% is associated with new-onset, device-determined AHREs for patients undergoing PM implantation for SND. HRSc may have prognostic and therapeutic implications.
Collapse
Affiliation(s)
- Katsuhide Hayashi
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio.
| | - Haruhiko Abe
- Department of Heart Rhythm, University of Occupational and Environmental Health, Japan, Kitakyushu, Japan
| | - Brian Olshansky
- Department of Internal Medicine, University of Iowa Hospital and Clinics, Iowa City, Iowa
| | | | | | | | | | - Ritsuko Kohno
- Department of Heart Rhythm, University of Occupational and Environmental Health, Japan, Kitakyushu, Japan
| | - Gregory Y H Lip
- Department of Cardiovascular Medicine, Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom
| | - Niraj Varma
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio
| | - Bruce L Wilkoff
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
3
|
Huttelmaier MT, Münsterer S, Morbach C, Sahiti F, Scholz N, Albert J, Gabel A, Angermann C, Ertl G, Frantz S, Störk S, Fischer TH. Activated rate-response is associated with increased mortality risk in cardiac device carriers with acute heart failure. PLoS One 2024; 19:e0302321. [PMID: 38635729 PMCID: PMC11025974 DOI: 10.1371/journal.pone.0302321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 04/01/2024] [Indexed: 04/20/2024] Open
Abstract
AIMS This study investigated whether an activated R-mode in patients carrying a cardiac implantable electronic device (CIED) is associated with worse prognosis during and after an episode of acutely decompensated heart failure (AHF). METHODS Six hundred and twenty-three patients participating in an ongoing prospective cohort study that phenotypes and follows patients admitted for AHF were studied. We compared CIED carriers with activated R-mode stimulation (CIED-R) to CIED carriers not in R-mode (CIED-0) and patients without CIEDs (no-CIED). The independent impact of R-mode activation on 12-month all-cause death was examined using uni- and multivariable Cox proportional hazards regression taking into account potential confounders, and hazard ratios (HR) with their 95% confidence intervals (CI) were reported. RESULTS Mean heart rate on admission was lower in CIED-R (n = 37, 16% women) vs. CIED-0 (n = 64, 23% women) or no-CIED (n = 511, 43% women): 70 bpm vs. 80 bpm or 82 bpm; both p<0.001. In-hospital mortality was similar across groups, but age- and sex-adjusted all-cause 12-month mortality risk was differentially affected by R-mode activation; CIED-R vs. CIED-0: HR 2.44, 95%CI 1.25-4.74; CIED-R vs. no-CIED: HR 2.61, 95%CI 1.59-4.29. These effects persisted after multivariable adjustment for potential confounders. Within CIED-R, mortality risk was similar in patients with pacemakers vs. ICDs and in subgroups with left ventricular ejection fraction (LVEF) <50% vs. ≥50%. CONCLUSION In patients admitted with AHF, R-mode stimulation was associated with a significantly increased 12-month mortality risk. Our findings shed new light on "admission heart rate" as a potentially treatable target in AHF. Our data are compatible with the concept that chronotropic incompetence contributes to an adverse outcome in these patients and may not be adequately treated through accelerometer-based R-mode stimulation.
Collapse
Affiliation(s)
| | - Sascha Münsterer
- Dept. of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Caroline Morbach
- Dept. of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Floran Sahiti
- Dept. of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Nina Scholz
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Judith Albert
- Dept. of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Alexander Gabel
- Helmholtz Institute for RNA-based Infection Research (HIRI), Helmholtz Centre for Infection Research (HZI), Würzburg, Germany
- Infection Control and Antimicrobial Stewardship Unit, University Hospital Würzburg, Würzburg, Germany
| | - Christiane Angermann
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Georg Ertl
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Stefan Frantz
- Dept. of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Stefan Störk
- Dept. of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
- Dept. Clinical Research & Epidemiology, Comprehensive Heart Failure Centre Würzburg, Würzburg, Germany
| | - Thomas H. Fischer
- Dept. of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
| |
Collapse
|
4
|
Niu H, Yu Y, Ravikumar V, Gold MR. The impact of chronotropic incompetence on atrioventricular conduction times in heart failure patients. J Interv Card Electrophysiol 2023; 66:2055-2062. [PMID: 37036553 DOI: 10.1007/s10840-023-01545-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 04/03/2023] [Indexed: 04/11/2023]
Abstract
BACKGROUND Intrinsic atrioventricular (AV) conduction is used to optimize AV intervals with cardiac resynchronization therapy (CRT) in most device algorithms. Atrial pacing and heart rate affect conduction times, but little is known regarding differeces among chronotropic incompetent(CI) and competent(CC) patients to guide programming. METHODS RAVE was a multicenter prospective trial of CRT patients. Heart rate was increased with incremental atrial pacing and with submaximal exercise. According to the maximal heart rate achieved during exercise, patients were classified as either CI or CC. For CI patients, an additional symptom-limited exercise with rate-adaptive pacing activated was performed. Intracardiac intervals were measured from the implantable lead electrograms in multiple postures. RESULTS There were 12 subjects with CI and 24 with CC. With atrial pacing, AV interval immediately increased and gradually increased with incremental atrial pacing in all patients. However, the changes in the atrial to right ventricular (ARV) and atrial to left ventricular (ALV) intervals with increasing atrial pacing rates were about threefold greater in CI patients compared to CC patients (24.3 ± 28.9 vs. 7.2 ± 5.5 ms/10 bpm for ARV and 22.7 ± 25.6 vs. 7.1 ± 5.7 ms/10 bpm for ALV in the standing position, p < 0.05). In CI pacing with rate-adaptive pacing during exercise, AV interval changes with paced heart rate were variable. CONCLUSIONS The AV response to overdrive atrial pacing at rest may provide a simple means of identifying chronotropic competence in CRT patients. For patients with CI, who often require rate-adaptive atrial pacing, rate-adaptive AV algorithms should be adjusted individually.
Collapse
Affiliation(s)
- Hongxia Niu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | | | | | - Michael R Gold
- Division of Cardiology, Medical University of South Carolina, 30 Courtenay Drive, MSC 592, Charleston, SC, 29425, USA.
| |
Collapse
|
5
|
Olshansky B, Ricci F, Fedorowski A. Importance of resting heart rate. Trends Cardiovasc Med 2023; 33:502-515. [PMID: 35623552 DOI: 10.1016/j.tcm.2022.05.006] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 05/20/2022] [Accepted: 05/20/2022] [Indexed: 11/30/2022]
Abstract
Resting heart rate is a determinant of cardiac output and physiological homeostasis. Although a simple, but critical, parameter, this vital sign predicts adverse outcomes, including mortality, and development of diseases in otherwise normal and healthy individuals. Temporal changes in heart rate can have valuable predictive capabilities. Heart rate can reflect disease severity in patients with various medical conditions. While heart rate represents a compilation of physiological inputs, including sympathetic and parasympathetic tone, aside from the underlying intrinsic sinus rate, how resting heart rate affects outcomes is uncertain. Mechanisms relating resting heart rate to outcomes may be disease-dependent but why resting heart rate in otherwise healthy, normal individuals affects outcomes remains obscure. For specific conditions, physiologically appropriate heart rate reductions may improve outcomes. However, to date, in the normal population, evidence that interventions aimed at reducing heart rate improves outcomes remains undefined. Emerging data suggest that reduction in heart rate via vagal activation and/or sympathetic inhibition is propitious.
Collapse
Affiliation(s)
- Brian Olshansky
- Division of Cardiology, Department of Internal Medicine, University of Iowa, Iowa City, IA 52242, USA.
| | - Fabrizio Ricci
- Department of Neuroscience, Imaging and Clinical Sciences, "G.d'Annunzio" University of Chieti-Pescara, Via dei Vestini, 33, Chieti 66100, Italy; Department of Clinical Sciences, Lund University, 214 28 Malmö, Sweden
| | - Artur Fedorowski
- Department of Clinical Sciences, Lund University, 214 28 Malmö, Sweden; Department of Cardiology, Karolinska University Hospital, and Department of Medicine, Karolinska Institute, 171 76 Stockholm, Sweden
| |
Collapse
|
6
|
Hayashi K, Abe H, Olshansky B, Sharma AD, Jones PW, Wold N, Perschbacher D, Kohno R, Richards M, Wilkoff BL. Initial heart rate score predicts new-onset atrial tachyarrhythmias in pacemaker patients. Europace 2023; 25:euad242. [PMID: 37552791 PMCID: PMC10440628 DOI: 10.1093/europace/euad242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 07/01/2023] [Indexed: 08/10/2023] Open
Abstract
AIMS Heart rate score (HRSc), the per cent of atrial paced and sensed event in the largest 10 b.p.m. rate histogram bin of a pacemaker, predicts survival in patients with cardiac devices. No correlation between HRSc and development of atrial fibrillation (AF) has been reported. In this study, we evaluated the relationship between pacemaker post-implantation HRSc and the incidence of newly developed atrial tachyarrhythmias (ATAs). METHODS AND RESULTS Patients with dual-chamber pacemakers, implanted 2013-17, with the LATITUDE remote monitoring data with ≥600 000 beats of histogram data collected at baseline were included (N = 34 543). Heart rate score was determined from the initial 3-month post-implantation histogram data. Patients were excluded if they had ATAs, defined as atrial high-rate episodes >5 min or >1% of right atrial beats >170 b.p.m. during the initial 3 months post-implantation. New ATAs, after the baseline period, were defined by each of the following: >1, >10, or >25% of atrial beats >170 b.p.m. or atrial tachycardia response (ATR) events >24 h. Patients were followed a median of 2.8 (1.0-4.0) years. The incidence of ATAs increased in proportion to HRSc (log-rank P-value <0.001), and the initial HRSc ≥70% was associated with increased ATAs by all definitions. Patients with initial HRSc ≥70% were older, had a higher percentage of right atrium pacing (%RA pacing), had a lower percentage of right ventricular pacing (%RV pacing), and were more likely programmed with rate-response vs. subjects with HRSc <70%. Initial HRSc (hazard ratio: 1.07, 95% confidence interval: 1.05-1.09; P < 0.0001) independently predicted ATAs after adjusting for age, gender, %RV pacing, and rate-response programming. The %RA pacing and initial HRSc were correlated. CONCLUSION Heart rate score independently predicts any subsequent duration of ATAs in pacemaker patients.
Collapse
Affiliation(s)
- Katsuhide Hayashi
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - Haruhiko Abe
- Department of Heart Rhythm Management, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Brian Olshansky
- Department of Internal Medicine-Cardiovascular Medicine, University of Iowa Hospital and Clinics, Iowa City, IA, USA
| | | | | | | | | | - Ritsuko Kohno
- Department of Heart Rhythm Management, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Mark Richards
- Department of Cardiology, Yakima Valley Memorial Hospital, Yakima, WA, USA
| | - Bruce L Wilkoff
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| |
Collapse
|
7
|
Hsu JC, Hesselson AB, Liang JJ, Mountantonakis S, David GT, Costea A. Atrial fibrillation associated with heart failure treated by a 2-lead CRT-DX system (BIO-AffectDX): Study design and clinical protocol. Heart Rhythm O2 2022; 2:642-650. [PMID: 34988510 PMCID: PMC8703153 DOI: 10.1016/j.hroo.2021.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Background Evidence to support use of cardiac resynchronization therapy (CRT) among patients with both heart failure (HF) and atrial fibrillation (AF) is largely limited to retrospective or post hoc subanalyses. Data from a prospectively enrolled and contemporary cohort are needed. Objective We aim to better characterize the changes from baseline in HF patients with concomitant AF subsequently implanted with a 2-lead CRT-DX system capable of sensing in the atrium, aggregating diagnostics, and delivering CRT therapy. The primary objective of this study is to evaluate the percentage of all HF subjects with an improvement in a clinical composite score from pre-CRT implant to 12 months. Methods The study is a US-based, prospective, observational multicenter clinical trial conducted at up to 50 sites and enrolling approximately 400 subjects with a follow-up period of 1 year. Multiple subject assessments, atrial rhythm status, and device interrogation will be collected at follow-up visits occurring at 3, 6, and 12 months postimplant. Results A Clinical Events Committee will adjudicate subject HF events, arrhythmia events, death events, and all device-classified ventricular tachycardia and ventricular fibrillation episodes with treatment that are collected throughout the follow-up period. Their decisions are based on independent physician review of the data from sites and device interrogation. Conclusion The BIO-AffectDX study aims to provide further insight into the expected outcomes from CRT treatment in patients with HF and AF.
Collapse
Affiliation(s)
- Jonathan C Hsu
- Cardiac Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California, San Diego, La Jolla, California
| | - Aaron B Hesselson
- University of Kentucky Gill Heart & Vascular Institute, Lexington, Kentucky
| | - Jackson J Liang
- Electrophysiology, Division of Cardiology, Internal Medicine, University of Michigan, Ann Arbor, Michigan
| | - Stavros Mountantonakis
- Division of Cardiac Electrophysiology, Lenox Hill Hospital, Northwell Health, New York, New York
| | | | - Alexandru Costea
- Clinical Cardiac Electrophysiology at University of Cincinnati Medical Center, Cincinnati, Ohio
| |
Collapse
|
8
|
Gopinathannair R, Sharma A, Jones P, English C, Furmanek S, Olshansky B. Heart rate score and outcomes in ICD patients: insights from the prospective randomized INTRINSIC RV trial. J Interv Card Electrophysiol 2021; 64:87-93. [PMID: 34778910 DOI: 10.1007/s10840-021-01091-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 11/08/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND Heart rate score (HRSc), the percentage of atrial sensed and paced beats in the largest 10 beat/min bin of a device histogram and mean intrinsic heart rate (MIHR), predicted survival in nonrandomized studies of implantable defibrillator (ICD) patients. We evaluated whether HRSc and MIHR independently predicted mortality and heart failure (HF) hospitalization in the prospective, randomized, controlled INTRINSIC RV trial. METHODS AND RESULTS The INTRINSIC RV trial enrolled 1530 patients receiving dual-chamber ICDs. This analysis involves patients (n = 1471) for whom MIHR and HRSc data were available. Mean follow-up was 10.4 months. The relationship between pre-randomization MIHR and HRSc on the primary endpoint of all-cause mortality and HF hospitalization was assessed using multivariate regression and Cox modeling. As categorical variables, MIHR > 70 bpm and HRSc > 70% were considered high. RESULTS The median baseline MIHR and HRSc were 74 (IQR = 16) and 50% (IQR = 20) respectively. As a continuous variable, for every 1% increase in HRSc, death/HF hospitalization increased by 1% (95%CI: 1.002-1.017; p = 0.01). Regression analysis showed baseline MIHR was associated with HRSc (p = 0.01); for every 1 beat/min increase in MIHR, HRSc increased by 1.8%. A MIHR > 70 bpm and HRSc ≥ 70% predicted, but were independently associated with, the primary endpoint (HR: 1.39; 95%CI: 1.10-1.76, p = 0.005 for MIHR and HR: 1.654; 95%CI: 1.11-2.46, p = 0.01 for HRSc). Male gender (HR: 0.75), history of HF (HR: 1.29), and atrial fibrillation (HR: 1.37) also predicted death/hospitalization in the Cox model. CONCLUSIONS In this large, prospectively studied ICD population, HRSc was a robust and independent predictor of death/HF hospitalization. High MIHR and high HRSc were associated but each predicted outcomes independently.
Collapse
Affiliation(s)
- Rakesh Gopinathannair
- Kansas City Heart Rhythm Institute, 5100 W 110th St, Ste 200, Overland Park, KS, 66211, USA.
| | - Arjun Sharma
- Medical Devices Consultants LLC, Saint Paul, MN, USA
| | - Paul Jones
- Boston Scientific Corp, Minneapolis, MN, USA
| | | | | | - Brian Olshansky
- University of Iowa Hospitals and Clinics, Iowa City, IA, USA
| |
Collapse
|
9
|
Sharma AD, Wilkoff BL, Richards M, Wold N, Jones P, Perschbacher D, Olshansky B. Lower rate limit for pacing by cardiac resynchronization defibrillators: Should lower rate programming be reconsidered? Heart Rhythm 2021; 18:2087-2093. [PMID: 34371194 DOI: 10.1016/j.hrthm.2021.07.068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 07/30/2021] [Accepted: 07/30/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND No real-world large database associates lower rate limit (LRL) programming and survival of subjects with cardiac resynchronization therapy-defibrillators (CRT-Ds). OBJECTIVE The purpose of this study was to test the hypothesis that lower LRL programming is independently associated with survival, and that LRL and heart rate score (HrSc) are associated. METHODS All dual-chamber CRT-D devices in the Remote Patient Monitoring (RPM) ALTITUDE database (2006-2011) were queried. Baseline HrSc was defined as the percentage of all atrial sensed and paced beats in the tallest 10-beat histogram bin postimplant. LRL was assessed during repeated RPM uploads. Using a Cox model multivariable analysis, relationships between LRL, survival, HrSc, and other variables were evaluated. Survival was determined by query of death indices. RESULTS Data analyzed included 61,881 subjects (mean follow-up 2.9 years). LRL ranged from 40 to 85 bpm. Baseline lower LRL was associated with younger age, less atrial fibrillation, female sex, and lower HrSc (P <.001 for all covariates). Lower LRL was associated with improved survival, with LRL 40 associated with the largest survival benefit. This was significant for all 3 HrSc subgroups (P <.001). An interaction between HrSc and LRL was observed, with the largest survival difference between HrSc groups observed at LRL-40 (P <.001). CONCLUSION LRL programming and HrSc were associated, and lower values of both were associated with improved survival in a large database of CRT-D subjects. Relationships between survival, LRL programming, and HrSc merit further study.
Collapse
|
10
|
Czermak T, Seitelberger V, Hagl C, Samson-Himmelstjerna PN, Groß S, Sadoni S, Heyn O, Kellnar A, Hartrampf B, Lemmermöhle E, Klier I, Rehms R, Hoffmann S, Estner HL, Fichtner S, Lackermair K. Survival after left ventricular assist device implantation correlates with a novel device-based measure of heart rate variability: the heart rate score. Interact Cardiovasc Thorac Surg 2021; 33:309-315. [PMID: 34027967 DOI: 10.1093/icvts/ivab063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 11/06/2020] [Accepted: 12/06/2020] [Indexed: 12/27/2022] Open
Abstract
OBJECTIVES The heart rate score (HRS) serves as a device-based measure of impaired heart rate variability and is an independent predictor of death in patients with heart failure and a cardiac implantable electrical device. However, no data are available for predicting death from the HRS in patients with end stage heart failure and a left ventricular assist device. METHODS From November 2011 to July 2018, a total of 56 patients with a pre-existing cardiac implantable electrical device underwent left ventricular assist device implantation at our 2 study sites. The ventricular HRS was calculated retrospectively during the first cardiac implantable electrical device follow-up examination following the index hospitalization. Survival during follow-up was correlated with initial HRS. RESULTS During the follow-up period, 46.4% of the patients (n = 26) died. The median follow-up period was 33.2 months. The median HRS after the index hospitalization was 41.1 ± 21.8%. More patients with an HRS >65% died compared to patients with an HRS <30% (76.9% vs 14.4%; P = 0.007). CONCLUSIONS In our multicentre experience, survival of patients after an left ventricular assist device implant correlates with the HRS. After confirmation of our findings in a larger cohort, the effect of rate-responsive pacing will be within the scope of further investigation.
Collapse
Affiliation(s)
- Thomas Czermak
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| | - Valentina Seitelberger
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| | - Christian Hagl
- Department of Cardiac Surgery, University Hospital Munich, Ludwig Maximilians University, Munich, Germany.,Department of Cardiac Surgery, Klinikum Augustinum, Munich, Germany
| | - Patrick-Nicolas Samson-Himmelstjerna
- Department of Cardiac Surgery, University Hospital Munich, Ludwig Maximilians University, Munich, Germany.,Department of Cardiac Surgery, Klinikum Augustinum, Munich, Germany
| | - Sven Groß
- Department of Cardiac Surgery, University Hospital Munich, Ludwig Maximilians University, Munich, Germany.,Department of Cardiac Surgery, Klinikum Augustinum, Munich, Germany
| | - Sebastian Sadoni
- Department of Cardiac Surgery, University Hospital Munich, Ludwig Maximilians University, Munich, Germany.,Department of Cardiac Surgery, Klinikum Augustinum, Munich, Germany
| | - Oliver Heyn
- Department of Cardiac Surgery, University Hospital Munich, Ludwig Maximilians University, Munich, Germany.,Department of Cardiac Surgery, Klinikum Augustinum, Munich, Germany
| | - Antonia Kellnar
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| | - Bonnie Hartrampf
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| | - Eric Lemmermöhle
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| | - Ina Klier
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| | - Raphael Rehms
- Institute for Medical Information Processing, Biometry and Epidemiology (IBE), Munich, Germany
| | - Sabine Hoffmann
- Institute for Medical Information Processing, Biometry and Epidemiology (IBE), Munich, Germany
| | - Heidi L Estner
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| | - Stephanie Fichtner
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| | - Korbinian Lackermair
- Department of Medicine I, University Hospital Munich, Ludwig Maximilians University, Munich, Germany
| |
Collapse
|
11
|
Sharma AD, Richards M, Olshansky B, Wold N, Jones P, Perschbacher D, Wilkoff BL. Heart rate score, a measure related to chronotropic incompetence in pacemaker patients. Heart Rhythm O2 2021; 2:124-131. [PMID: 34113914 PMCID: PMC8183967 DOI: 10.1016/j.hroo.2021.02.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Heart rate score (HrSc) ≥70% in cardiac resynchronization therapy defibrillator and implantable cardioverter-defibrillator subjects predicts 5-year mortality risk. A high HrSc suggests few sensed cardiac cycles above the programmed lower rate. OBJECTIVE To determine if HrSc is related to chronotropic incompetence (CI) in pacemaker (PM) subjects. METHODS HrSc is the percentage of all atrial-paced and sensed events in the single tallest 10 beats/min histogram bin programmed to DDD 60/min. The prospective LIFE study of PM subjects examined multiple treadmill-based measures of CI. The 1-month postimplant DDD 60/min PM rate histogram prior to treadmill was retrospectively analyzed for HrSc. Measures of CI were applied to submaximal treadmill data in the DDD mode. HrSc was compared to these CI measures and to clinical indications for PM. RESULTS The 1-month histogram demonstrated HrSc ≥70% in 43% of subjects. HrSc ≥70% correlated with a clinical diagnosis of sick sinus syndrome (P < .001). CI was present in 34%-88% of subjects by treadmill-based measures. Agreement between treadmill-based measures for CI was poor and varied from 39% to 83%. HrSc ≥70%, as a measure of CI, was most highly correlated with unpaced heart rate <70% of age-predicted maximum heart rate (67%) (odds ratio 3.7, P < .001). CONCLUSIONS HrSc ≥70% correlates with treadmill measures of CI and clinical sick sinus syndrome. HrSc ≥70% is a measure of CI in PM subjects that is inexpensive, repeatable, and quantitative.
Collapse
|
12
|
Arimoto T, Watanabe E, Kohno R, Shimeno K, Kikuchi K, Doi A, Inoue K, Nitta T, Nogami A, Abe H, Okumura K. Impact of a poor functional capacity on the clinical outcomes in patients with a pacemaker implantation -Results from the Japanese Heart Rhythm Society Registry. J Arrhythm 2021; 37:182-188. [PMID: 33664901 PMCID: PMC7896460 DOI: 10.1002/joa3.12459] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 10/13/2020] [Accepted: 10/28/2020] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Functional capacity (FC) correlates with mortality in various cardiovascular diseases. The aim of this study was to examine whether cardiac pacemaker implantations improve the FC and affect the prognosis. METHODS AND RESULTS We prospectively enrolled 621 de novo pacemaker recipients (age 76 ± 9 years, 50.7% male). The FC was assessed by metabolic equivalents (METs) during the implantation and periodically thereafter. The patients were a priori classified into poor FC (<2 METs, n = 40), moderate FC (2 ≤ METs < 4, n = 239), and good FC (≥4 METs, n = 342). Three months after the pacemaker implantation, poor FC or moderate FC patients improved to a good FC by 43%. The distribution of the three FCs remained at those levels until after 1 year of follow-up (P = .18). During a median follow-up of 2.4 years, 71 patients (11%) had cardiovascular hospitalizations and 35 (5.6%) all-cause death. A multivariate Cox analysis revealed that a poor FC at baseline was an independent predictor of both cardiovascular hospitalization (hazard ratio [HR] 2.494, P = .012) and all-cause death (HR 3.338, P = .016). One year after the pacemaker implantation, the eight who remained with a poor FC had a high mortality rate of 37.5% (P < .01). CONCLUSION Approximately half of the poor or moderate FC patients improved to good FC 3 months after the pacemaker implantation. The baseline FC predicted the prognosis, and patients with an improved FC after the pacemaker implantation had a better prognosis.
Collapse
Affiliation(s)
- Takanori Arimoto
- Department of CardiologyYamagata University School of MedicineYamagataJapan
| | - Eiichi Watanabe
- Department of CardiologyFujita Health University Bantane HospitalNagoyaJapan
| | - Ritsuko Kohno
- Department of Heart Rhythm ManagementUniversity of Occupational and Environmental HealthKitakyushuJapan
| | - Kenji Shimeno
- Department of CardiologyOsaka City General HospitalOsakaJapan
| | - Kan Kikuchi
- Division of CardiologyJapan Community Healthcare Organization Kyushu HospitalKitakyushuJapan
| | - Atsushi Doi
- Department of Cardiovascular MedicineOsaka City University Graduate School of MedicineOsakaJapan
| | - Kanki Inoue
- Division of CardiologySakakibara Heart InstituteTokyoJapan
| | - Takashi Nitta
- Cardiovascular SurgeryNippon Medical SchoolTokyoJapan
| | - Akihiko Nogami
- Department of CardiologyFaculty of MedicineUniversity of TsukubaTsukubaJapan
| | - Haruhiko Abe
- Department of Heart Rhythm ManagementUniversity of Occupational and Environmental HealthKitakyushuJapan
| | - Ken Okumura
- Division of CardiologySaiseikai Kumamoto HospitalKumamotoJapan
| |
Collapse
|
13
|
Vamos M, Nemeth M, Balazs T, Zima E, Duray GZ. Rationale and feasibility of the atrioventricular single-lead ICD systems with a floating atrial dipole (DX) in clinical practice. Trends Cardiovasc Med 2021; 32:84-89. [PMID: 33482321 DOI: 10.1016/j.tcm.2021.01.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 01/12/2021] [Accepted: 01/14/2021] [Indexed: 01/30/2023]
Abstract
Cardiac implantable electronic devices establish proper therapy for the prevention of sudden cardiac death, significantly reducing the morbidity and mortality of patients with arrhythmias and heart failure. It is well-known that the number of electrodes increases the risk of complications. To preserve the benefit of atrial sensing without the need to implant an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD lead) has been developed. Besides all of the potential benefits, the necessity of a reliable and stable atrial sensing via the floating dipole could be the main concern against the use of this lead type. In the current generation of DX devices, the specially filtered atrial signal seems to be high enough and stable over time, which is crucial in the early detection of atrial arrhythmias, discrimination between different forms of tachycardias in order to prevent inappropriate ICD therapy, and achieving an optimal atrioventricular and interventricular synchrony in patients with a two-lead CRT-DX system. The present review summarizes the benefits and potential drawbacks of the DX ICD systems based on the available literature, furthermore, proposes an evidence-based algorithm of ICD type selection.
Collapse
Affiliation(s)
- Mate Vamos
- Department of Internal Medicine, Cardiac Electrophysiology Division, University of Szeged, Semmelweis u. 8., 6725 Szeged, Szeged, Hungary.
| | | | | | - Endre Zima
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Gabor Zoltan Duray
- Department of Cardiology, Medical Centre, Hungarian Defense Forces, Budapest, Hungary
| |
Collapse
|
14
|
Mangi MA, Nesheiwat Z, Kahloon R, Moukarbel GV. CardioMEMS TM System in the Daily Management of Heart Failure: Review of Current Data and Technique of Implantation. Expert Rev Med Devices 2020; 17:637-648. [PMID: 32500762 DOI: 10.1080/17434440.2020.1779588] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
INTRODUCTION Heart failure (HF) leads to significant morbidity and mortality and imposes a large economic burden. Although there have been several advances in HF monitoring and management, HF-rehospitalization remains a significant problem. Remote monitoring of HF to detect early signs of decompensation has emerged in past years as an option to prevent or reduce the incidence of HF rehospitalization. The CardioMEMSTM HF system is a wireless pulmonary artery (PA) pressure monitoring system that detects changes in PA pressure and transmits data to the healthcare provider. Since changes in PA pressure happen early in the course of HF decompensation, the CardioMEMSTM system allows the provider to institute timely intensification of HF therapies to alter the course. In trial and registry data, the use of the CardioMEMSTM HF system has been associated with reduction in HF hospitalization, improvement in quality of life, symptoms, and physical activity. AREAS COVERED This review will focus on the available data supporting its utilization in patients with HF. EXPERT OPINION CardioMEMSTM is relatively safe and cost-effective, reduces heart failure hospitalization rates, and fits into intermediate to high-value medical care.
Collapse
Affiliation(s)
- Muhammad Asif Mangi
- Department of Medicine, University of Toledo College of Medicine and Life Sciences , Toledo, Ohio, USA
| | - Zeid Nesheiwat
- Department of Medicine, University of Toledo College of Medicine and Life Sciences , Toledo, Ohio, USA
| | - Rehan Kahloon
- Department of Medicine, University of Tennessee College of Medicine Chattanooga , Chattanooga, Tennessee, USA
| | - George V Moukarbel
- Department of Medicine, University of Toledo College of Medicine and Life Sciences , Toledo, Ohio, USA
| |
Collapse
|
15
|
Heart rate score predicts mortality independent of shocks in ICD and CRT-D patients. J Interv Card Electrophysiol 2019; 58:103-111. [PMID: 31875270 DOI: 10.1007/s10840-019-00688-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Accepted: 12/12/2019] [Indexed: 10/25/2022]
Abstract
BACKGROUND Heart Rate Score (HrSc), a novel index found to predict mortality in patients with implantable defibrillator (ICD) and cardiac resynchronization defibrillator (CRT-D) devices, is associated with mortality in ICD and CRT-D recipients when HrSc is ≥ 70%. Implantable defibrillator shocks have also been associated with increased mortality in ICD and CRT-D recipients. The objective of this study was to evaluate the relationships between HrSc, shocks, and mortality in ICD and CRT-D patients. METHODS HrSc was calculated from atrial sensed and paced rate histograms collected from the 2006-2011 ALTITUDE remote interrogation database. Shocks were determined in the first year of follow-up. Mortality was assessed over the next 4 years by the Social Security Death Index. Four multivariable models were run: ICD and CRT-D, shock and no shock, with mortality as the outcome and HrS as predictor. RESULTS Data from 49,358 ICD and 55,953 CRT-D patients were divided into HrSc: ≥ 70%, 30-69%, and < 30%. Shock rates differed between HrSc groups (p < 0.001) for ICD and CRT-D patients. However, the lowest mortality risk HrSc (< 30%) had the highest shock rate. Both highest HrSc (> 70%; p < 0.001) and shocks (p < 0.001) predicted mortality during follow-up. Mortality was unrelated to interactions between HrSc and shocks in ICD patients (p = 0.275) or CRT-D patients (p < 0.079). Comparing HrSc ≥ 70% to HrSc < 30%, HrSc ≥ 70% predicted mortality in CRT-D (HR 1.40; 95% CI 1.29-1.52) and ICD (HR 1.23; 95% CI 1.11-1.36) patients regardless of shocks (P < 0.001 for both). CONCLUSIONS Patients with ICDs or CRT-Ds having the lowest mortality risk HrSc had the highest shock rate. Shocks and HrSc appear to complement each other as predictors of mortality.
Collapse
|
16
|
Zweerink A, van der Lingen ALCJ, Handoko ML, van Rossum AC, Allaart CP. Chronotropic Incompetence in Chronic Heart Failure. Circ Heart Fail 2019; 11:e004969. [PMID: 30354566 DOI: 10.1161/circheartfailure.118.004969] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Chronotropic incompetence (CI) is generally defined as the inability to increase the heart rate (HR) adequately during exercise to match cardiac output to metabolic demands. In patients with heart failure (HF), however, this definition is unsuitable because metabolic demands are unmatched to cardiac output in both conditions. Moreover, HR dynamics in patients with HF differ from those in healthy subjects and may be affected by β-blocking medication. Nevertheless, it has been demonstrated that CI in HF is associated with reduced functional capacity and poor survival. During exercise, the normal heart increases both stroke volume and HR, whereas in the failing heart, contractility reserve is lost, thus rendering increases in cardiac output primarily dependent on cardioacceleration. Consequently, insufficient cardioacceleration because of CI may be considered a major limiting factor in the exercise capacity of patients with HF. Despite the profound effects of CI in this specific population, the issue has drawn limited attention during the past years and is often overlooked in clinical practice. This might partly be caused by a lack of standardized approach to diagnose the disease, further complicated by changes in HR dynamics in the HF population, which render reference values derived from a normal population invalid. Cardiac implantable electronic devices (implantable cardioverter defibrillator; cardiac resynchronization therapy) now offer a unique opportunity to study HR dynamics and provide treatment options for CI by rate-adaptive pacing using an incorporated sensor that measures physical activity. This review provides an overview of disease mechanisms, diagnostic strategies, clinical consequences, and state-of-the-art device therapy for CI in HF.
Collapse
Affiliation(s)
- Alwin Zweerink
- Department of Cardiology, Amsterdam Cardiovascular Sciences, VU University Medical Center, the Netherlands
| | | | - M Louis Handoko
- Department of Cardiology, Amsterdam Cardiovascular Sciences, VU University Medical Center, the Netherlands
| | - Albert C van Rossum
- Department of Cardiology, Amsterdam Cardiovascular Sciences, VU University Medical Center, the Netherlands
| | - Cornelis P Allaart
- Department of Cardiology, Amsterdam Cardiovascular Sciences, VU University Medical Center, the Netherlands
| |
Collapse
|
17
|
Biffi M, D'Onofrio A, Pignalberi C, Pisanò EC, Iacopino S, Curnis A, Senatore G, Capucci A, Della Bella P, Calvi V, Zanotto G, Caravati F, Maglia G, Manzo M, Santamaria M, Ziacchi M, Lissoni F, Giacopelli D, Gargaro A, Solimene F. Rate-responsive pacing and atrial high rate episodes in cardiac resynchronization therapy patients: Is low heart rate the key? Clin Cardiol 2019; 42:820-828. [PMID: 31282000 PMCID: PMC6727874 DOI: 10.1002/clc.23227] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 06/20/2019] [Accepted: 06/28/2019] [Indexed: 01/24/2023] Open
Abstract
BACKGROUND The role of atrial rate-responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor. HYPOTHESIS The presence of an association between RR and the incidence of AHREs. METHODS Daily remote transmissions from 836 CRT recipients were analyzed. AHREs were classified by duration: ≥15 minutes, ≥5 hours, and ≥ 24 hours. Variables possibly associated to AHREs were included in time-dependent proportional-hazard models, averaging over 30-day periods and adjusting for main baseline variables. RESULTS After a median follow-up of 23.9 (12.2-36.0) months, 507 (60.6%) patients experienced at least one 15-minute AHRE. RR function was programmed in 166 (19.8%) patients and was associated with an increased AHRE occurrence rate with hazard ratio (HR) ranging from 1.45 to 1.78 for the 3 cutoffs of episode duration. The negative effect of RR function was not observed in the subset of patients with low mean heart rate (<68 bpm). Higher mean heart rates increased AHRE risk (HR:1.02, P = .01), while CRT amount decreased it (HR:0.98, P < .01). The extent of atrial pacing did not predict AHRE occurrence. CONCLUSIONS RR pacing in CRT recipients is associated with increased AHRE occurrence, especially when an average heart rate > 68 bpm is attained.
Collapse
Affiliation(s)
- Mauro Biffi
- Policlinico Sant'Orsola‐MalpighiBolognaItaly
| | | | | | | | | | | | | | | | | | - Valeria Calvi
- Policlinico Vittorio Emanuele PO FerrarottoCataniaItaly
| | | | | | | | - Michele Manzo
- Azienda Ospedaliera Universitaria S.Giovanni di Dio e Ruggi D'AragonaSalernoItaly
| | | | | | | | | | | | | |
Collapse
|
18
|
Predictors of rate-adaptive pacing in patients implanted with implantable cardioverter–defibrillator and subsequent differential clinical outcomes. J Interv Card Electrophysiol 2019; 55:83-91. [DOI: 10.1007/s10840-019-00536-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2018] [Accepted: 03/06/2019] [Indexed: 10/27/2022]
|
19
|
Richards M, Olshansky B, Sharma AD, Wold N, Jones P, Perschbacher D, Wilkoff BL. Addition of minute ventilation to rate-response pacing improves heart rate score more than accelerometer alone. Heart Rhythm 2018; 15:1730-1735. [DOI: 10.1016/j.hrthm.2018.06.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Indexed: 10/14/2022]
|
20
|
Biffi M, Massaro G, Candelora A, Angeletti A, Valzania C, Martignani C, Grassini D, Diemberger I, Ziacchi M. Less is more: Can we achieve cardiac resynchronization with 2 leads only? Int J Cardiol 2017; 249:184-190. [DOI: 10.1016/j.ijcard.2017.09.189] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Revised: 08/17/2017] [Accepted: 09/22/2017] [Indexed: 10/18/2022]
|
21
|
WILKOFF BRUCEL, RICHARDS MARK, SHARMA ARJUN, WOLD NICHOLAS, JONES PAUL, PERSCHBACHER DAVID, OLSHANSKY BRIAN. A Device Histogram-Based Simple Predictor of Mortality Risk in ICD and CRT-D Patients: The Heart Rate Score. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2017; 40:333-343. [DOI: 10.1111/pace.13036] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2016] [Revised: 12/09/2016] [Accepted: 01/08/2017] [Indexed: 11/28/2022]
Affiliation(s)
| | - MARK RICHARDS
- Northwest Ohio Cardiology Consultants; ProMedica Cardiology; Toledo Ohio
| | | | | | | | | | | |
Collapse
|