1
|
Safety and efficacy of the novel Alpha stent for the treatment of intracranial wide-necked aneurysm. Sci Rep 2024; 14:8723. [PMID: 38622273 PMCID: PMC11018798 DOI: 10.1038/s41598-024-59363-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 04/09/2024] [Indexed: 04/17/2024] Open
Abstract
The Alpha stent is an intracranial closed-cell stent with a unique mesh design to enhance wall apposition. It recently underwent structural modifications to facilitate easier stent deployment. This study aimed to evaluate the safety and efficacy of stent-assisted coil embolization for unruptured intracranial aneurysms using the Alpha stent. Between January 2021 and November 2021, 35 adult patients with 35 unruptured intracranial aneurysms in the distal internal carotid artery were prospectively enrolled. For efficacy outcomes, magnetic resonance angiography at the 6-month follow-up was evaluated using the Raymond-Roy occlusion classification (RROC). The safety outcome evaluated the occurrence of symptomatic procedure-related neurological complications up to 6 months postoperatively. Technical success was achieved in 34/35 (97.1%). Six months postoperatively, aneurysm occlusion showed RROC I in 32/35 (91.4%) and RROC II in 3/35 (8.6%) patients. Procedure-related neurologic complications occurred in one patient (2.9%) who experienced hemiparesis due to acute lacunar infarction, which resulted in a 6-month mRS score of 1. The Alpha stent demonstrated excellent efficacy and safety outcomes in stent-assisted coil embolization of unruptured distal ICA aneurysms. The recent structural modifications allowed for easier stent delivery and deployment.Clinical trial registration number: KCT0005841; registration date: 28/01/2021.
Collapse
|
2
|
Intracranial aneurysms treated with stent-assisted coil embolization: evaluation with four-dimensional ultrashort-TE MR angiography. Eur Radiol 2023; 33:7923-7933. [PMID: 37284863 DOI: 10.1007/s00330-023-09755-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 02/23/2023] [Accepted: 03/10/2023] [Indexed: 06/08/2023]
Abstract
OBJECTIVES As a novel follow-up method for intracranial aneurysms treated with stent-assisted coil embolization (SACE), we developed four-dimensional magnetic resonance angiography (MRA) with minimized acoustic noise utilizing ultrashort-echo time (4D mUTE-MRA). We aimed to assess whether 4D mUTE-MRA is useful for the evaluation of intracranial aneurysms treated with SACE. METHODS This study included 31 consecutive patients with intracranial aneurysm treated with SACE who underwent 4D mUTE-MRA at 3 T and digital subtraction angiography (DSA). For 4D mUTE-MRA, five dynamic MRA images with a spatial resolution of 0.5 × 0.5 × 0.5 mm3 were obtained every 200 ms. Two readers independently reviewed the 4D mUTE-MRA images to evaluate the aneurysm occlusion status (total occlusion, residual neck, and residual aneurysm) and the flow in the stent using a 4-point scale (from 1 [not visible] to 4 [excellent]). The interobserver and intermodality agreement was assessed using κ statistics. RESULTS On DSA images, 10 aneurysms were classified as total occlusion, 14 as residual neck, and 7 as residual aneurysm. In terms of aneurysm occlusion status, the intermodality and interobserver agreement was excellent (κ = 0.92 and κ = 0.96, respectively). For the flow in the stents on 4D mUTE-MRA, the mean score was significantly higher for single stents than multiple stents (p < .001) and for open-cell type stents than closed-cell type (p < .01). CONCLUSIONS 4D mUTE-MRA is a useful tool with a high spatial and temporal resolution for the evaluation of intracranial aneurysms treated with SACE. KEY POINTS • In the evaluation of intracranial aneurysms treated with SACE on 4D mUTE-MRA and DSA, the intermodality and interobserver agreement in aneurysm occlusion status was excellent. • 4D mUTE-MRA shows good to excellent visualization of flow in the stents, especially for cases treated with a single or open-cell stent. • 4D mUTE-MRA can provide hemodynamic information related to embolized aneurysms and the distal arteries to stented parent arteries.
Collapse
|
3
|
Endovascular treatment in bilateral cavernous sinus dural arteriovenous fistulas: a systematic review and meta-analysis. Sci Rep 2023; 13:7108. [PMID: 37528115 PMCID: PMC10394050 DOI: 10.1038/s41598-023-31864-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Accepted: 03/20/2023] [Indexed: 08/03/2023] Open
Abstract
Few studies have discussed the disease nature and treatment outcomes for bilateral cavernous sinus dural arteriovenous fistula (CSDAVF). This study aimed to investigate the clinical features and treatment outcomes of bilateral CSDAVF. Embase, Medline, and Cochrane library were searched for studies that specified the outcomes of bilateral CSDAVF from inception to April 2022. The classification, clinical presentation, angiographic feature, surgical approach, and treatment outcomes were collected. Meta-analysis was performed using the random effects model. Eight studies reporting 97 patients were included. The clinical presentation was mainly orbital (n = 80), cavernous (n = 52) and cerebral (n = 5) symptoms. The most approached surgical route was inferior petrosal sinus (n = 80), followed by superior orbital vein (n = 10), and alternative approach (n = 7). Clinical symptoms of 88% of the patients (95% CI 80-93%, I2 = 0%) were cured, and 82% (95% CI 70-90%, I2 = 7%) had angiographic complete obliteration of fistulas during follow up. The overall complication rate was 18% (95% CI 11-27%, I2 = 0%). Therefore, endovascular treatment is an effective treatment for bilateral CSDAVF regarding clinical or angiographic outcomes. However, detailed evaluation of preoperative images and comprehensive surgical planning of the approach route are mandatory owing to complexity of the lesions.
Collapse
|
4
|
Morphological Factors affecting Coil-Only Embolization of Small Unruptured Aneurysms. Asian J Neurosurg 2023; 18:125-131. [PMID: 37056877 PMCID: PMC10089743 DOI: 10.1055/s-0043-1763528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
Abstract:
Objective When small unruptured aneurysms (SUA) are embolized by coils, manipulation of the microcatheter and coil is limited because of their small size. Previous studies suggested that the morphology of the artery and aneurysm is important. In the present study, we clarified the morphological factors affecting coil-only embolization of SUA.
Patients and Methods We retrospectively identified 17 patients who underwent embolization for unruptured aneurysm with a maximum diameter less than 5 mm. We investigated the following: (1) the relationships among dome/neck ratio (D/N), height/neck ratio (H/N), height/dome ratio (H/D), projection of aneurysm-parent artery, and adverse events, (2) immediate and late occlusion, and (3) number of coils.
Results (1) Adverse events developed in three cases in which the H/D was smaller than 1 (p < 0.02). There was a significant difference in the rate of adverse events by projection of the aneurysm-parent artery (p < 0.03), (2) Occlusion rate: Immediately after coil embolization, 71% (12/17) were neck remnant; however, 88% (15/17) of SUA became complete occlusion in the follow-up term, and (3) 1.5 ± 0.6 coils were used.
Conclusion To achieve successful coil-only embolization in SUAs, it is important to select aneurysms for which the projection of the parent artery is suitable for embolizing and the H/D ratio is larger than 1. In SUAs, occlusion develops naturally after coil embolization.
Collapse
|
5
|
Ultrashort Echo Time Magnetic Resonance Angiography as an Alternative Tool to Digital Subtraction Angiography in the Follow-up of Stent-Assisted Coil Embolization Outcomes. Neurosurgery 2023; 92:574-580. [PMID: 36512845 DOI: 10.1227/neu.0000000000002273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 09/20/2022] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Follow-up of aneurysms treated with stent-assisted coil embolization has been performed using digital subtraction angiography (DSA) because in time-of-flight magnetic resonance angiography, metal artifacts from the stent often affect visualization. OBJECTIVE To confirm whether ultrashort echo time (TE) MRA may be an alternative for DSA during follow-up. METHODS Patients with unruptured aneurysms initially treated with stent-assisted coil embolization between April 2019 and March 2021 were enrolled. After 3 months of treatment, follow-up DSA and ultrashort TE MRA were performed. All images were independently reviewed by neurosurgeons to evaluate in-stent flow and rated from 1 (not visible) to 4 (excellent). Aneurysmal embolization status was assessed as complete obliteration, residual neck, or residual aneurysm. Ultrashort TE MRA findings were classified as evaluative or nonevaluative state based on the presence of metal artifacts. We investigated the types of aneurysms that were evaluative and the agreement between ultrashort TE and DSA. RESULTS Overall, 89 aneurysms were examined, of which 74% (n = 66) were classified as evaluative on ultrashort TE. Significant differences were observed in size and stent type. Evaluative cases had an aneurysm size of <7 mm ( P = .0007) and a higher rate of Neuroform Atlas ( P = .0006). The rate of agreement between ultrashort TE with evaluative state and DSA was 95%. CONCLUSION Ultrashort TE MRA could evaluate an embolization status treated with stenting, and the findings are in excellent agreement with those of DSA. Aneurysms measuring <7 mm and treated with Neuroform Atlas are evaluative on ultrashort TE, and DSA might not be necessary.
Collapse
|
6
|
Usefulness of Pointwise Encoding Time Reduction with Radial Acquisition-Magnetic Resonance Angiography after Endovascular Treatment for Intracranial Aneurysms. Interv Neuroradiol 2023; 29:20-29. [PMID: 34913378 PMCID: PMC9893233 DOI: 10.1177/15910199211065906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 10/19/2021] [Accepted: 11/18/2021] [Indexed: 02/05/2023] Open
Abstract
PURPOSE Imaging follow-up after endovascular treatment is important; however, time-of-flight magnetic resonance angiography (TOF-MRA) has limitations associated with magnetic susceptibility and radiofrequency shielding caused by the stent and coils. We evaluated the diagnostic performance of pointwise encoding time reduction with radial acquisition (PETRA)-MRA after endovascular treatment for intracranial aneurysms. MATERIAL AND METHODS A total of 186 patients with 211 aneurysms who underwent both pointwise encoding time reduction with radial acquisition- and time-of-flight magnetic resonance angiography in the same imaging session for follow-up after endovascular treatment. We subjectively graded the overall image quality, visualization of treated sites, and occlusion status. RESULTS Although the overall image quality scores of pointwise encoding time reduction with radial acquisition-magnetic resonance angiography were significantly lower than those of time-of-flight magnetic resonance angiography for both observers (4.04 ± 0.81 vs. 4.85 ± 0.35 [observer 1], 4.60 ± 0.69 vs. 4.94 ± 0.24 [observer 2]) (both P < .001), the visibility of treated sites using pointwise encoding time reduction with radial acquisition-magnetic resonance angiography was significantly better than that of time-of-flight magnetic resonance angiography overall (4.27 ± 0.97 vs. 3.42 ± 1.01; P < .001), in the distal internal carotid artery (4.46 ± 0.79 vs. 3.40 ± 1.00; P < .001), and in the middle cerebral artery (4.19 ± 0.93 vs. 3.08 ± 0.53, P = 0.007). Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed a higher area under the curve than time-of-flight magnetic resonance angiography for the evaluation of treated aneurysm occlusion, except for posterior circulation aneurysms. CONCLUSIONS Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed better visualization of treated sites and better diagnostic performance than time-of-flight magnetic resonance angiography for anterior circulation aneurysms. However, Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed limitations in the follow-up evaluation of posterior circulation aneurysms.
Collapse
|
7
|
Usefulness of Silent Magnetic Resonance Angiography in the Follow-Up of Endovascular-Treated Intracranial Aneurysm: A Prospective Study. J Stroke Cerebrovasc Dis 2021; 31:106256. [PMID: 34923434 DOI: 10.1016/j.jstrokecerebrovasdis.2021.106256] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 11/23/2021] [Accepted: 11/26/2021] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVES To prospectively evaluate the clinical usefulness of Silent magnetic resonance angiography (Silent MRA) in the follow-up of endovascular-treated intracranial aneurysms by comparing it with time-of-flight magnetic resonance angiography (TOF MRA) and digital subtraction angiography (DSA). METHODS Patients with endovascular-treated saccular aneurysms and followed with Silent MRA, TOF MRA, and DSA in our center were included. The visualization of the treated sites in the two MRA sequences was assessed using a 5-point scale. The aneurysm occlusion status according to each of the three imaging modalities was assessed using a 3-point scale. RESULTS Forty-one patients with 46 saccular aneurysms were recruited. The image quality score of Silent MRA was significantly higher than that of TOF MRA (4.32 ± 0.87 vs. 3.08 ± 1.48, P < 0.001). In the aneurysms treated by simple coiling, the maximal aneurysm diameter showed a strong negative correlation with image quality score in TOF MRA (Spearman's r = -0.519, P = 0.033), while it showed no significant correlation in Silent MRA (r = -0.037, P = 0.887). For the aneurysm occlusion status, inter-modality agreement was excellent (κ = 0.845) between DSA and Silent MRA, but poor (κ = 0.185) between DSA and TOF MRA. CONCLUSIONS Silent MRA was superior to TOF MRA in the follow-up of endovascular-treated intracranial aneurysms and showed excellent consistency with DSA in the evaluation of aneurysm occlusion. Therefore, Silent MRA is useful for the follow-up of endovascular-treated aneurysms.
Collapse
|
8
|
Usefulness of Craniograms in Discriminating Coiled Intracranial Aneurysms Requiring Retreatment. Neurol Med Chir (Tokyo) 2021; 62:118-124. [PMID: 34880195 PMCID: PMC8918367 DOI: 10.2176/nmc.oa.2021-0225] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
While endovascular coil embolization has become one of the major therapeutic modalities for intracranial aneurysms, long-term imaging follow-up is required because of the higher rate of retreatment compared with surgical clipping. The purpose of this study was to show the usefulness of craniograms to discriminate coiled intracranial aneurysms that required retreatment. Under the study protocol approved by institutional review board, a retrospective review of the medical record was done regarding coil embolization for intracranial aneurysms performed between January 2014 and December 2018. Coil embolization performed as the initial treatment and followed up for more than 1 year without additional treatment, and those performed as retreatment after the initial coil embolization performed at our institution were recruited. Craniograms obtained just after the initial treatment were compared with those obtained just before the additional treatment in the retreated cases and compared with the latest ones in the non-recurrence cases. Correlation between the morphological changes in the coil mass on the craniograms and retreatments was evaluated. During the study period, 288 coil embolization procedures for intracranial aneurysms were performed. From these, 191 treatments that were followed up for more than 1 year without any additional treatments and 30 retreatments were included. Morphological change of the coil mass was observed in 4 of the 191 non-recurrence treatments and 26 of the 30 retreatments, which was significantly correlated with retreatments (p <0.001). Craniogram was a useful modality in following up the coiled intracranial aneurysms to detect those required retreatments.
Collapse
|
9
|
Application of 3D T1-SPACE combined with 3D-TOF sequence for follow-up evaluation of stent-assisted coil embolization for intracranial aneurysm. J Interv Med 2021; 4:71-76. [PMID: 34805951 PMCID: PMC8562288 DOI: 10.1016/j.jimed.2021.02.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 02/22/2021] [Accepted: 02/23/2021] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES To assess 3D T1-SPACE combined with 3D-TOF sequence for follow-up evaluation of stent-assisted coil embolization for intracranial aneurysm. MATERIALS AND METHODS Between Oct 2018 and May 2019, we enrolled 25 patients with intracranial aneurysm who underwent stent-assisted coil embolization. All patients were followed up for 6 to10 months after endovascular treatment (EVT) using 3D-TOF MRA, 3D T1-SPACE and DSA to evaluate aneurysm occlusion and parent artery patency. RESULTS With regards to aneurysm occlusion, the specificity of 3D-TOF MRA was 86.9% (20/23) and the accuracy was 84% (21/25). There was no statistical significance (P = 0.409) compared with the DSA. The parent artery by 3D-TOF MRA showed that there were 14 patients with grade 3, 8 patients with grade 2 and 3 patients with grade 1. However, 3D T1-SPACE showed that all 25 patients were grade 4, and were clearly displayed without metal artifacts. The comparison of the two MR techniques demonstrated that 3D T1-SPACE was superior to 3D-TOF MRA in the evaluation of parent artery (P<0.001). CONCLUSIONS 3D T1-SPACE sequence provides better image quality and higher accuracy for evaluating stented parent arteries compared to TOF-MRA. This study also shows that 3D-TOF MRA has a merit to evaluate aneurysm occlusion. The combination of these two modalities can be used as an optional follow-up evaluation after EVT of intracranial aneurysms.
Collapse
|
10
|
Utility of skull X-rays in identifying recurrence of coiled cerebral aneurysms. J Cerebrovasc Endovasc Neurosurg 2021; 23:108-116. [PMID: 33902273 PMCID: PMC8256019 DOI: 10.7461/jcen.2021.e2020.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 01/15/2021] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE A high rate of cerebral aneurysm recurrence following endovascular coiling has prompted the use of digital subtraction angiography (DSA) for interval follow-up. However, the utility of skull x-rays as an alternative screening method for aneurysm recurrence is unproperly characterized. METHODS Retrospective review of a prospective registry of ruptured and unruptured cerebral aneurysms. Anteroposterior and lateral skull x-rays were obtained immediately at the end of the procedure and at 6-month follow-up. Aneurysm recurrence was defined by comparing post-procedure and 6-month DSA imaging. A true positive was defined as a change in coil mass morphology on at least one projection with aneurysm recurrence on DSA, and a true negative defined as a stable coil mass on both projections and no recurrence on DSA. Receiver operating characteristic area under the curve (AUC) statistics was used to assess the performance of skull x-rays in identifying aneurysm recurrence. RESULTS A total of 118 cerebral aneurysms were evaluated with DSA imaging and skull x-rays. A change in coil mass morphology on one projection of skull x-rays correctly detected all true recurrences with a sensitivity of 100% (95% confidence interval [CI], 91-100%). Skull x-rays failed to identify a stable aneurysm coil mass in 15 cases, with a specificity of 79% (68-88%). Skull x-rays performed with AUC 0.8958 (95% CI, 0.8490-0.9431) in identifying aneurysm recurrence. CONCLUSIONS The findings of our study suggest that skull x-rays may represent a lowcost, non-invasive screening tool to rule out aneurysm recurrence, which can potentially aid in decreasing the utilization of DSA in the follow-up of patients with coiled cerebral aneurysms.
Collapse
|
11
|
Ultrashort Echo Time Magnetic Resonance Angiography in Follow-up of Intracranial Aneurysms Treated With Endovascular Coiling: Comparison of Time-of-Flight, Pointwise Encoding Time Reduction With Radial Acquisition, and Contrast-Enhanced Magnetic Resonance Angiography. Neurosurgery 2021; 88:E179-E189. [PMID: 33319900 DOI: 10.1093/neuros/nyaa467] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 08/11/2020] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The optimal magnetic resonance angiography (MRA) sequence for assessing the aneurysm occlusion state or in-stent flow after endovascular coiling is not well established. OBJECTIVE To evaluate the diagnostic performance of pointwise encoding time reduction with radial acquisition (PETRA)-MRA in patients who underwent endovascular coiling relative to that of time-of-flight (TOF)-MRA and contrast-enhanced (CE)-MRA. METHODS We evaluated the aneurysm occlusion state using digital subtraction angiography (DSA) and MRA. In patients who underwent stent-assisted coiling, we estimated the visibility of in-stent flow. RESULTS We enrolled 189 patients with assessable TOF, PETRA, and CE-MRAs after coiling. In patients who underwent simple coiling (128 patients), PETRA showed a higher sensitivity in the detection of residual flow than TOF and CE (PETRA, 100%; CE, 83%; TOF, 80%). There were no significant differences in the height of residual flow between DSA (0.68 ± 1.45 mm) and PETRA (0.70 ± 1.50 mm; P = 1.000). In patients who underwent stent-assisted coiling (61 patients), PETRA showed the highest sensitivity (88%) in detecting residual flow (CE, 56%; TOF, 31%). Regarding in-stent flow, PETRA, CE, and TOF showed visual scores of ≥3 with frequencies of 96.7%, 85.2%, and 37.7%, respectively. Relative signal-to-noise ratio of PETRA (0.62 ± 0.18) was significantly higher than that of CE (0.56 ± 0.12) and TOF (0.39 ± 0.12; P < .001 for both). CONCLUSION PETRA-MRA showed excellent diagnostic performance in terms of residual flow detection and in-stent flow assessment. PETRA could be a versatile alternative sequence for following up patients with coiled aneurysm.
Collapse
|
12
|
Usefulness of 3D T1-SPACE in Combination With 3D-TOF MRA for Follow-Up Evaluation of Intracranial Aneurysms Treated With Pipeline Embolization Devices. Front Neurol 2020; 11:542493. [PMID: 33362681 PMCID: PMC7759539 DOI: 10.3389/fneur.2020.542493] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Accepted: 11/09/2020] [Indexed: 01/10/2023] Open
Abstract
Object: Follow-up evaluation of intracranial aneurysms treated by flow-diverting stents using MRI is challenging due to the presence of imaging artifacts. This study evaluated 3D T1-SPACE in combination with 3D-TOF sequence for follow-up evaluation of intracranial aneurysms treated with Pipeline embolization devices. Methods: Forty patients with 53 intracranial aneurysms who were treated with Pipeline Embolization Devices from October 2018 to July 2019 were enrolled in this study. All patients were evaluated for aneurysm occlusion and stent patency 4 to 7 months post-treatment using 3D T1-SPACE sequence, 3D-TOF MRA, and DSA examinations. Results: With regards to aneurysm occlusion, the intermodality (DSA and 3D-TOF MRA) agreement was good (κ = 0.755). The specificity of 3D-TOF MRA was 94.4% (34/36), the sensitivity was 76.5% (13/17), the total coincidence rate was 88.7% (47/53). With regards to the patency of the stented arteries after PED treatment, 3D T1-SPACE sequence was more accurate compared to 3D-TOF MRA (Z = −6.283, P < 0.001), with a no-artifact rate of 95.7% (44/46). Conclusions: 3D T1-SPACE sequence provides better image quality and higher accuracy for evaluating stented parent arteries compared to TOF-MRA. 3D-TOF MRA may be valuable in the evaluation of aneurysm occlusion. The combination of these two modalities may be used for long-term follow-up of intracranial aneurysms treated with Pipeline Embolization Devices.
Collapse
|
13
|
The clinical value of ceMRA versus DSA for follow-up of intracranial aneurysms treated by coil embolization: an assessment of occlusion classifications and impact on treatment decisions. Eur Radiol 2020; 31:4104-4113. [PMID: 33221944 DOI: 10.1007/s00330-020-07492-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Revised: 09/10/2020] [Accepted: 11/10/2020] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this study was a detailed analysis of the value of contrast-enhanced magnetic resonance angiography (ceMRA) compared to digital subtraction angiography (DSA) for follow-up imaging of intracranial aneurysms treated by coil embolization. METHODS Patients with coiled aneurysms and follow-up exams including both DSA and 3 T ceMRA were retrospectively identified. In blinded readings, both modalities were graded according to the modified Raymond-Roy classification (MRRC) and the Meyers scale. Additionally, readers were asked to make a decision regarding retreatment/follow-up based on the respective imaging findings. RESULTS The study comprised 92 patients harboring 102 coiled aneurysms. There was good intermethod agreement of DSA and ceMRA concerning both the MRRC (κ = 0.64) and the Meyers scale (κ = 0.74). Agreement regarding occlusion of < 90% of the aneurysm (Meyers grade ≥ 2) was very good (κ = 0.87). Regarding the detection of a remnant with contrast between the coil mass and the aneurysm wall (MRRC IIIb), there were 12 discrepant findings and agreement was good (κ = 0.70). Comparing treatment/follow-up decisions, the two methods agreed very well (κ = 0.92). In seven patients with discrepant treatment decisions, the authors concurred with DSA in four cases and with ceMRA in three cases when evaluating both modalities together. Interval aneurysm growth was found in more cases with ceMRA (n = 19) than with DSA (n = 16). CONCLUSIONS CeMRA is very unlikely to miss a relevant aneurysm remnant and thus could be suitable as the primary follow-up method. In case of remnant growth or recurrence, however, additional DSA might be required to guide treatment decisions. KEY POINTS • There is high accordance between ceMRA and DSA regarding the evaluation of intracranial aneurysms treated by endovascular coil embolization, but closer analysis also revealed relevant differences. • CeMRA could be suitable as the primary follow-up imaging modality, potentially eliminating the need for routine DSA. • DSA will still be required in case of aneurysm remnant growth or recurrence as detected by ceMRA.
Collapse
|
14
|
Assessing the Hemodynamics in Residual Cavities of Intracranial Aneurysm after Coil Embolization with Combined Computational Flow Dynamics and Silent Magnetic Resonance Angiography. J Stroke Cerebrovasc Dis 2020; 29:105290. [PMID: 32992205 DOI: 10.1016/j.jstrokecerebrovasdis.2020.105290] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 08/21/2020] [Accepted: 08/26/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND AND PURPOSE Metal artifacts limit computational fluid dynamics analysis after coil embolization. Silent magnetic resonance angiography reduces metal artifacts and improves visualization of the residual cavity of coil-embolized aneurysms. This study investigated the flow dynamics of the residual cavity after coil embolization using silent magnetic resonance angiography and computational fluid dynamics to elucidate the hemodynamic characteristics of recanalization. METHODS Twenty internal carotid-posterior communicating aneurysm cases treated with coil embolization and without stent assistance were followed up (mean±standard deviation, 13.0±6.1 months) and assessed using silent magnetic resonance angiography. The hemodynamic characteristics of the residual cavities in both types of aneurysms were compared between neck remnants, which persisted for >12 months (NR group), and those treated with coil compaction-induced body filling (BF group). Computational fluid dynamics analysis of each aneurysm was performed using morphological data obtained from silent magnetic resonance angiography. Pressure, pressure difference, normalized wall shear stress, and flow velocity were measured. RESULTS The residual cavity was well-visualized using silent magnetic resonance angiography and compared with those imaged using conventional time-of-flight magnetic resonance angiography, and eight internal carotid-posterior communicating aneurysms with neck remnants and body filling were investigated. The maximum pressure area was localized to the aneurysm wall in the NR group (n=4) and to sides of the coil surface in the BF group (n=4). No significant differences were observed for each hemodynamic parameter. CONCLUSIONS Combination of silent magnetic resonance angiography and computational fluid dynamics helps to understand the hemodynamic characteristics of residual cavity in coil- embolized aneurysms. The flow-impingement zone at the coil surface (maximum pressure area) may influence the risk for future coil compaction.
Collapse
|
15
|
Effect of aneurysm size on procedure-related rupture in patients with subarachnoid hemorrhage treated with coil occlusion. INTERDISCIPLINARY NEUROSURGERY 2020. [DOI: 10.1016/j.inat.2019.100566] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
16
|
Magnetic Resonance Imaging in Aneurysmal Subarachnoid Hemorrhage: Current Evidence and Future Directions. Neurocrit Care 2019; 29:241-252. [PMID: 29633155 DOI: 10.1007/s12028-018-0534-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND Aneurysmal subarachnoid hemorrhage (aSAH) is associated with an unacceptably high mortality and chronic disability in survivors, underscoring a need to validate new approaches for treatment and prognosis. The use of advanced imaging, magnetic resonance imaging (MRI) in particular, could help address this gap given its versatile capacity to quantitatively evaluate and map changes in brain anatomy, physiology and functional activation. Yet there is uncertainty about the real value of brain MRI in the clinical setting of aSAH. METHODS In this review, we discuss current and emerging MRI research in aSAH. PubMed was searched from inception to June 2017, and additional studies were then chosen on the basis of relevance to the topics covered in this review. RESULTS Available studies suggest that brain MRI is a feasible, safe, and valuable testing modality. MRI detects brain abnormalities associated with neurologic examination, outcomes, and aneurysm treatment and thus has the potential to increase knowledge of aSAH pathophysiology as well as to guide management and outcome prediction. Newer pulse sequences have the potential to reveal structural and physiological changes that could also improve management of aSAH. CONCLUSION Research is needed to confirm the value of MRI-based biomarkers in clinical practice and as endpoints in clinical trials, with the goal of improving outcome for patients with aSAH.
Collapse
|
17
|
Is 3 years adequate for tracking completely occluded coiled aneurysms? J Neurosurg 2019; 133:758-764. [PMID: 31419789 DOI: 10.3171/2019.5.jns183651] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Accepted: 05/14/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The authors conducted a study to ascertain the long-term durability of coiled aneurysms completely occluded at 36 months' follow-up given the potential for delayed recanalization. METHODS In this retrospective review, the authors examined 299 patients with 339 aneurysms, all shown to be completely occluded at 36 months on follow-up images obtained between 2011 and 2013. Medical records and radiological data acquired during the extended monitoring period (mean 74.3 ± 22.5 months) were retrieved, and the authors analyzed the incidence of (including mean annual risk) and risk factors for delayed recanalization. RESULTS A total of 5 coiled aneurysms (1.5%) occluded completely at 36 months showed recanalization (0.46% per aneurysm-year) during the long-term surveillance period (1081.9 aneurysm-years), 2 surfacing within 60 months and 3 developing thereafter. Four showed minor recanalization, with only one instance of major recanalization. The latter involved the posterior communicating artery as an apparent de novo lesion, arising at the neck of a firmly coiled sac, and was unrelated to coil compaction or growth. Additional embolization was undertaken. In a multivariate analysis, a second embolization for a recurrent aneurysm (HR = 22.088, p = 0.003) independently correlated with delayed recanalization. CONCLUSIONS Almost all coiled aneurysms (98.5%) showing complete occlusion at 36 months postembolization proved to be stable during extended observation. However, recurrent aneurysms were predisposed to delayed recanalization. Given the low probability yet seriousness of delayed recanalization and the possibility of de novo aneurysm formation, careful monitoring may be still considered in this setting but at less frequent intervals beyond 36 months.
Collapse
|
18
|
MRA versus DSA for the follow-up imaging of intracranial aneurysms treated using endovascular techniques: a meta-analysis. J Neurointerv Surg 2019; 11:1009-1014. [PMID: 31048457 DOI: 10.1136/neurintsurg-2019-014936] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 04/10/2019] [Accepted: 04/15/2019] [Indexed: 12/16/2022]
Abstract
BACKGROUND Treated aneurysms must be followed over time to ensure durable occlusion, as more than 20% of endovascularly treated aneurysms recur. While digital subtraction angiography (DSA) remains the gold standard, magnetic resonance angiography (MRA) is attractive as a non-invasive follow-up technique. Two different MRA techniques have traditionally been used: time-of-flight (TOF) and contrast-enhanced (CE) MRA. We analysed data from studies comparing MRA techniques with DSA for the follow-up of aneurysms undergoing endovascular treatment. Subgroup analysis of stent-assisted coiling (SAC) and flow diversion (FD) techniques was completed. METHODS Comprehensive searches using the Embase, PubMed, and Cochrane databases were performed and updated to November 2018. Pooled sensitivity and specificity were calculated using aneurysm occlusion status as defined by the Raymond-Roy occlusion grading scale. RESULTS The literature search yielded 1579 unique titles. Forty-three studies were included. For TOF-MRA, sensitivity and specificity of all aneurysms undergoing endovascular therapy were 88% and 94%, respectively. For CE-MRA, the sensitivity and specificity were 88% and 96%, respectively. For SAC and FD techniques, sensitivity and specificity of TOF-MRA were 86% and 95%, respectively. CE-MRA had sensitivity and specificity of 90% and 92%. CONCLUSION MRA is a reliable modality for the follow-up of aneurysms treated using endovascular techniques. While the data are limited, MRA techniques can also be used to reliably follow patients undergoing FD and SAC. However, clinical factors must be used to optimize follow-up regimens for individual patients.
Collapse
|
19
|
ACR Appropriateness Criteria ® Cerebrovascular Disease. J Am Coll Radiol 2018; 14:S34-S61. [PMID: 28473091 DOI: 10.1016/j.jacr.2017.01.051] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Revised: 01/27/2017] [Accepted: 01/31/2017] [Indexed: 11/23/2022]
Abstract
Diseases of the cerebral vasculature represent a heterogeneous group of ischemic and hemorrhagic etiologies, which often manifest clinically as an acute neurologic deficit also known as stroke or less commonly with symptoms such as headache or seizures. Stroke is the fourth leading cause of death and is a leading cause of serious long-term disability in the United States. Eighty-seven percent of strokes are ischemic, 10% are due to intracerebral hemorrhage, and 3% are secondary to subarachnoid hemorrhage. The past two decades have seen significant developments in the screening, diagnosis, and treatment of ischemic and hemorrhagic causes of stroke with advancements in CT and MRI technology and novel treatment devices and techniques. Multiple different imaging modalities can be used in the evaluation of cerebrovascular disease. The different imaging modalities all have their own niches and their own advantages and disadvantages in the evaluation of cerebrovascular disease. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
Collapse
|
20
|
Comparison of 3D TOF MR angiographic accuracy in predicting Raymond grade of flow-diverted versus coiled intracranial aneurysms. J Clin Neurosci 2017; 42:182-185. [PMID: 28457861 DOI: 10.1016/j.jocn.2017.03.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2016] [Accepted: 03/05/2017] [Indexed: 10/19/2022]
Abstract
The accuracy of 3D time of Flight Magnetic Resonance Angiography (TOF MRA) has been studied extensively for following coiled intracranial aneurysms. It is used by many clinicians for non-invasive follow-up because of its adequate sensitivity in predicting aneurysmal recanalization compared to diagnostic cerebral angiography. The data on the accuracy of 3D TOF MRA for the Pipeline™ Embolization Device (PED) are sparse. In a retrospective chart review, we compared the accuracy of 3D TOF MRA of PED to coil embolization at our institution. 3D TOF MRA had a lower sensitivity and positive predictive value in detecting aneurysmal filling in PED-treated versus coiled aneurysms (57% versus 87% and 80% versus 100%, respectively). Analysis of discrepancies between conventional diagnostic angiography and 3D TOF MRA revealed that 3D TOF MRA was inaccurate in the setting of small residual necks and slow residual filling of the dome with fluid-fluid layers. Therefore, contrasted studies such as contrast-enhanced MRA may be preferred for non-invasively following PED-treated aneurysms to increase accuracy.
Collapse
|
21
|
Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms. AJNR Am J Neuroradiol 2016; 38:577-581. [PMID: 28007767 DOI: 10.3174/ajnr.a5033] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Accepted: 10/12/2016] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Y-configuration stent-assisted coil embolization is used for treating wide-neck aneurysms. Noninvasive alternatives to x-ray DSA for follow-up after Y-configuration stent-assisted coil embolization treatment are required. This study aimed to assess the usefulness of non-contrast-enhanced MRA by using a Silent Scan (silent MRA) for follow-up after Y-configuration stent-assisted coil embolization for basilar tip aneurysms. MATERIALS AND METHODS Seven patients treated with Y-configuration stent-assisted coil embolization for basilar tip aneurysms underwent silent MRA, 3D TOF-MRA, and DSA. Silent MRA and 3D TOF-MRA images were obtained during the same scan session on a 3T MR imaging system. Two neuroradiologists independently reviewed both types of MRA images and subjectively scored the flow in the stents on a scale of 1 (not visible) to 5 (nearly equal to DSA) by referring to the latest DSA image as a criterion standard. Furthermore, we evaluated the visualization of the neck remnant. RESULTS In all patients, the 2 observers gave a higher score for the flow in the stents on silent MRA than on 3D TOF-MRA. The average score ± standard deviation was 4.07 ± 0.70 for silent MRA and 1.93 ± 0.80 (P < .05) for 3D TOF-MRA. Neck remnants were depicted by DSA in 5 patients. In silent MRA, neck remnants were depicted in 5 patients, and visualization was similar to DSA; however, in 3D TOF-MRA, neck remnants were depicted in only 1 patient. CONCLUSIONS Silent MRA might be useful for follow-up after Y-configuration stent-assisted coil embolization.
Collapse
|
22
|
Guidelines for the Management of Patients With Unruptured Intracranial Aneurysms: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association. Stroke 2015; 46:2368-400. [PMID: 26089327 DOI: 10.1161/str.0000000000000070] [Citation(s) in RCA: 590] [Impact Index Per Article: 65.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
PURPOSE The aim of this updated statement is to provide comprehensive and evidence-based recommendations for management of patients with unruptured intracranial aneurysms. METHODS Writing group members used systematic literature reviews from January 1977 up to June 2014. They also reviewed contemporary published evidence-based guidelines, personal files, and published expert opinion to summarize existing evidence, indicate gaps in current knowledge, and when appropriate, formulated recommendations using standard American Heart Association criteria. The guideline underwent extensive peer review, including review by the Stroke Council Leadership and Stroke Scientific Statement Oversight Committees, before consideration and approval by the American Heart Association Science Advisory and Coordinating Committee. RESULTS Evidence-based guidelines are presented for the care of patients presenting with unruptured intracranial aneurysms. The guidelines address presentation, natural history, epidemiology, risk factors, screening, diagnosis, imaging and outcomes from surgical and endovascular treatment.
Collapse
|
23
|
Is visual evaluation of aneurysm coiling a reliable study end point? Systematic review and meta-analysis. Stroke 2015; 46:1574-81. [PMID: 25944331 DOI: 10.1161/strokeaha.114.008513] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2014] [Accepted: 04/10/2015] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND PURPOSE Angiographic occlusion as a surrogate marker of satisfactory aneurysm treatment is commonly used in clinical trials although some pitfalls have to be considered. To investigate the inter-rater reliability of visual rating of aneurysm occlusion as study end point, we performed a systematic review and meta-analysis. METHODS Electronic databases (MEDLINE, EMBASE, PubMed, and the Cochrane Library) were searched up to June 2014. Assessment of risk for bias was based on the Quality Appraisal Tool for Studies of Diagnostic Reliability and the Guidelines for Reporting Reliability and Agreement studies. Inter-rater reliability estimates were pooled across studies using meta-analysis, and the influence of several factors (eg, imaging methods, grading scales, and occlusion rate) was tested with meta-regression. RESULTS From 1193 titles, 644 abstracts and 87 full-text versions were reviewed. Twenty-six articles met the inclusion criteria and provided 77 reliability estimates. Twenty-one different rating scales were used, and statistical analysis varied. Mean inter-rater agreement of the pooled studies was substantial (κ=0.65; 95% confidence interval, 0.60-0.69). Reliability varied significantly as a function of imaging methods, grading scales, occlusion rates, and their interaction. Observer agreement substantially increased with increasing occlusion rate in digital subtraction angiography but not in MR angiography. Reliability was higher in studies using 2- or 3-value grading scales than in studies with 4-value grading scales. CONCLUSIONS There is significant heterogeneity between studies evaluating the reliability of visual evaluation of aneurysm coiling. On the basis of our analysis, we found that the combination of magnetic resonance angiography, 3-value grading scale, and 2 trained raters seems most promising for usage as surrogate study end points.
Collapse
|
24
|
Assessing Blood Flow in an Intracranial Stent: A Feasibility Study of MR Angiography Using a Silent Scan after Stent-Assisted Coil Embolization for Anterior Circulation Aneurysms. AJNR Am J Neuroradiol 2014; 36:967-70. [PMID: 25523588 DOI: 10.3174/ajnr.a4199] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2014] [Accepted: 10/29/2014] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Blood flow in an intracranial stent cannot be visualized with 3D time-of-flight MR angiography owing to magnetic susceptibility and radiofrequency shielding. As a novel follow-up tool after stent-assisted coil embolization, we applied MRA by using a Silent Scan algorithm that contains an ultrashort TE combined with an arterial spin-labeling technique (Silent MRA). The purpose of this study was to determine whether Silent MRA could visualize flow in an intracranial stent placed in the anterior circulation. MATERIALS AND METHODS Nine patients treated with stent-assisted coil embolization for anterior circulation aneurysms underwent MRAs (Silent MRA and TOF MRA) and x-ray digital subtraction angiography. MRAs were performed in the same session on a 3T unit. Two neuroradiologists independently reviewed the MRA images and subjectively scored flow in a stent as 1 (not visible) to 4 (excellent) by referring to the latest x-ray digital subtraction angiography image as a criterion standard. RESULTS Both observers gave MRA higher scores than TOF MRA for flow in a stent in all cases. The mean score for Silent MRA was 3.44 ± 0.53, and for TOF MRA, it was 1.44 ± 0.46 (P < .001). CONCLUSIONS Silent MRA was able to visualize flow in an intracranial stent more effectively than TOF MRA. Silent MRA might be useful for follow-up imaging after stent-assisted coil embolization, though these study results may be only preliminary due to some limitations.
Collapse
|
25
|
Optimized angiographic CT using intravenous contrast injection: a noninvasive imaging option for the follow-up of coiled aneurysms? AJNR Am J Neuroradiol 2014; 35:2341-7. [PMID: 25034780 DOI: 10.3174/ajnr.a4039] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Because recanalization of coiled cerebral aneurysms is reported to occur, follow-up imaging is mandatory, ideally noninvasively. Our study aimed to evaluate the accuracy of an optimized angiographic CT by using intravenous contrast material injection in the assessment of coiled cerebral aneurysms, compared with MR angiography and digital subtraction angiography, the criterion standard. MATERIALS AND METHODS We included 69 patients with 76 coiled cerebral aneurysms. In each patient, we performed an angiographic CT with intravenous contrast material injection with a dual rotational acquisition, a time-of-flight MR angiography, and a DSA. The angiographic CT with intravenous contrast material injection data was postprocessed by using newly implemented reconstructions modes and a dual-volume technique. An aneurysm occlusion rate was assessed in angiographic CT with intravenous contrast material injection and MRA; remnants were measured and correlated with DSA, respectively. RESULTS Twenty-eight remnants were revealed by DSA with a mean size of 3.1 × 3.1 mm. Angiographic CT with intravenous contrast material injection demonstrated a sensitivity of 93% and a specificity of 96% in remnant detection. MRA showed almost identical accuracy (sensitivity of 93%, specificity of 100%). Assessment of remnant size by angiographic CT with intravenous contrast material injection and by MRA revealed a high significant correlation with DSA, respectively (P < .001). CONCLUSIONS Optimized angiographic CT with intravenous contrast material injection and MRA demonstrated accuracy comparable with that of DSA in the follow-up of coiled aneurysms, respectively. The assessment of remnant size showed a high correlation with DSA for both techniques. Due to the lack of radiation exposure, MRA seems to be the preferred technique. However, angiographic CT with intravenous contrast material injection can be considered a reliable, noninvasive alternative in patients with MR imaging contraindications or in cases of compromising artifacts due to metal implants (ie, clips).
Collapse
|
26
|
Late onset aneurysm development following radiosurgical obliteration of a cerebellopontine angle meningioma. J Neurointerv Surg 2014; 7:e21. [PMID: 24847091 DOI: 10.1136/neurintsurg-2014-011206.rep] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/15/2014] [Indexed: 11/03/2022]
Abstract
The development of de novo intracranial aneurysms following stereotactic radiosurgery for intracranial pathology is a rare complication secondary to vascular injury. Typically, these aneurysms develop within the first few years after radiation surgery. We present the first case of an aneurysm developing 10 years after radiosurgery for a cerebellopontine angle meningioma. This case highlights the importance of careful long-term follow-up of patients who undergo radiosurgery for lesions abutting major vessels and/or who suffer post-radiation complications.
Collapse
|
27
|
Late onset aneurysm development following radiosurgical obliteration of a cerebellopontine angle meningioma. BMJ Case Rep 2014; 2014:bcr-2014-011206. [PMID: 24827655 DOI: 10.1136/bcr-2014-011206] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
The development of de novo intracranial aneurysms following stereotactic radiosurgery for intracranial pathology is a rare complication secondary to vascular injury. Typically, these aneurysms develop within the first few years after radiation surgery. We present the first case of an aneurysm developing 10 years after radiosurgery for a cerebellopontine angle meningioma. This case highlights the importance of careful long-term follow-up of patients who undergo radiosurgery for lesions abutting major vessels and/or who suffer post-radiation complications.
Collapse
|
28
|
Abstract
Abstract
Recent advancements in all phases of endovascular aneurysm treatment, including medical therapy, diagnostics, devices, and implants, abound. Advancements in endovascular technologies and techniques have enabled treatment of a wide variety of intracranial aneurysms. In this article, technical advances in endovascular treatment of cerebral aneurysms are discussed, with an effort to incorporate a clinically relevant perspective. Advancements in diagnostic tools, medical therapy, and implants are reviewed and discussed.
Collapse
|
29
|
Time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent for intracranial aneurysm: usefulness of source images. Korean J Radiol 2014; 15:161-8. [PMID: 24497808 PMCID: PMC3909851 DOI: 10.3348/kjr.2014.15.1.161] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Accepted: 09/23/2013] [Indexed: 11/15/2022] Open
Abstract
Objective The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms with the Enterprise stent. Materials and Methods Two experienced neurointerventionists independently reviewed the follow-up MRA studies of 40 consecutive patients with 44 coiled aneurysms. All aneurysms were treated with assistance from the Enterprise stent and the radiologic follow-up intervals were greater than 6 months after the endovascular therapy. Digital subtraction angiography (DSA) served as the reference standard. The degree of aneurysm occlusion was determined by an evaluation of the maximal intensity projection (MIP) and source images (SI) of the TOF MRA. The capability of the TOF MRA to depict the residual flow within the coiled aneurysms and the stented parent arteries was compared with that of the DSA. Results DSA showed stable occlusions in 25 aneurysms, minor recanalization in 8, and major recanalization in 11. Comparisons between the TOF MRA and conventional angiography showed that the MIP plus SI had almost perfect agreement (κ = 0.892, range 0.767 to 1.000) and had better agreement than with the MIP images only (κ = 0.598, range 0.370 to 0.826). In-stent stenosis of more than 33% was observed in 5 cases. Both MIP and SI of the MRA showed poor depiction of in-stent stenosis compared with the DSA. Conclusion TOF MRA seemed to be reliable in screening for aneurysm recurrence after coil embolization with Enterprise stent assistance, especially in the evaluation of the SI, in addition to MIP images in the TOF MRA.
Collapse
|
30
|
MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis. AJNR Am J Neuroradiol 2013; 35:1655-61. [PMID: 24008171 DOI: 10.3174/ajnr.a3700] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
MR angiography is proposed as a safer and less expensive alternative to the reference standard, DSA, in the follow-up of intracranial aneurysms treated with endovascular coil occlusion. We performed a systematic review and meta-analysis to evaluate the accuracy of TOF-MRA and contrast-enhanced MRA in detecting residual flow in the follow-up of coiled intracranial aneurysms. Literature was reviewed through the PubMed, Cochrane, and EMBASE data bases. In comparison with DSA, the sensitivity of TOF-MRA was 86% (95% CI: 82-89%), with a specificity of 84% (95% CI: 81-88%), for the detection of any recurrent flow. For contrast-enhanced MRA, the sensitivity and specificity were 86% (95% CI: 82-89%) and 89% (95% CI: 85-92%), respectively. Both TOF-MRA and contrast-enhanced MRA are shown to be highly accurate for detection of any recanalization in intracranial aneurysms treated with endovascular coil occlusion.
Collapse
|