1
|
Argilés M, Mangues-Villar M. Impact of sectorial hemifield occlusions on the motion perception of rotating snake illusion. Perception 2025; 54:214-218. [PMID: 39957146 DOI: 10.1177/03010066241311098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2025]
Abstract
This study investigates the impact of sectorial hemifield occlusions on the perception of the rotating snake illusion, a well-studied optical phenomenon. The rotating snake illusion induces the perception of movement in a static image and has been linked to cortical activation in areas such as hMT+ and MT. Binasal sectorial hemifield occlusions (BNO), which partially obscure the retina, have been explored in relation to mild traumatic brain injury and associated with increased visual evoked potentials. However, the mechanisms by which these occlusions modulate the perception of this illusion remain unclear. This study compared the effects of BNO and bitemporal occlusion (BTO) on the rotating snake illusion. Neurotypical participants rated the illusion's movement on a scale while being exposed to different occlusions. The results revealed that both BNO and BTO affect the perception of movement in the rotating snake illusion relative to baseline, but there was no evidence for a difference between these effects.
Collapse
|
2
|
Gong A, Busija L, Skalicky SE. Evaluating the Consistency of Online Circular Contrast Perimetry Across Different Computer Monitors: A Cross-sectional Study. J Curr Glaucoma Pract 2025; 19:15-27. [PMID: 40417139 PMCID: PMC12096869 DOI: 10.5005/jp-journals-10078-1468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2025] [Accepted: 02/19/2025] [Indexed: 05/27/2025] Open
Abstract
Aim and background The aim of this study is to evaluate the agreement between perimetric findings of a novel 24°, 52-loci online circular contrast perimetry (OCCP) application on three different computer monitors to determine its stability of testing across varying displays. Materials and methods Sixty-one participants (19 healthy controls, 42 with glaucoma) underwent SAP testing followed by OCCP testing on three uncalibrated computer monitors in randomized order: a large-screen (24-inch) desktop personal computer (DPC) (Dell, Texas, US), a 17-inch laptop (LPC) (Dell), and a 14-inch MacBook Pro (MP) (Apple, California, US). Results Agreement of mean deviation (MD), pattern standard deviation (PSD), and visual field index (VFI)/visual index (VI) values between MP, DPC, and LPC OCCP were strong, with intraclass correlations and Deming's coefficients ranging from 0.96 to 1.00 and 0.93 to 1.03, respectively. When OCCP tests were compared to SAP, ICCs and Deming's coefficients were less strong, ranging from 0.89 to 0.95 and 0.72 to 0.89. Bland-Altman analyses revealed higher biases (2.90 to 3.59 dB) and wider limits of agreement when comparing OCCP to SAP than when comparing OCCP on different monitors. Bland-Altman bias of contrast sensitivities for each 24-2 testing location revealed stronger relationships between OCCP tests on different monitors (-0.82 to 0.78) than between OCCP and SAP tests (-1.53 to 1.32). Conclusion OCCP demonstrates strong levels of test-retest agreement when performed on computer monitors of varying display and moderate to strong levels of correlation to SAP perimetric indices. Clinical significance With further enhancements, OCCP could potentially be used on different personal computers, which could help address current challenges in glaucoma care, such as limited access to traditional perimetric testing. This has the potential to expand the scope of glaucoma detection and monitoring, particularly in remote and underserved areas of our community. How to cite this article Gong A, Busija L, Skalicky SE. Evaluating the Consistency of Online Circular Contrast Perimetry Across Different Computer Monitors: A Cross-sectional Study. J Curr Glaucoma Pract 2025;19(1):15-27.
Collapse
Affiliation(s)
- Angela Gong
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, Victoria, Australia
| | - Lazar Busija
- Department of Glaucoma Investigation, Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia
| | - Simon Edward Skalicky
- Department of Surgery Ophthalmology, University of Melbourne; Department of Glaucoma Investigation, Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
3
|
Hoang TT, Mai TQ, Pham DT, Nguyen XT, Nguyen DA, Vu DT, Hoang HT, Nkurunziza M, Bigirimana D, Skalicky SE. Glaucoma Clinic Monitoring Over 6 Months Using Online Circular Contrast Perimetry in Comparison with Standard Automatic Perimetry: The Developing-World Setting. Clin Ophthalmol 2024; 18:3767-3780. [PMID: 39697638 PMCID: PMC11653856 DOI: 10.2147/opth.s496728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2024] [Accepted: 12/09/2024] [Indexed: 12/20/2024] Open
Abstract
Purpose Online circular contrast perimetry provides visual field testing on any computer or tablet without additional hardware. This study compared outcomes of online circular contrast perimetry (OCCP) and standard automated perimetry (SAP) in a developing world setting. Methods The longitudinal and observation study was conducted on patients sampled during 2023 at Hanoi Medical University Hospital. Participants were either healthy volunteers as controls or stable glaucoma patients with either primary angle closure or primary open-angle glaucoma. They underwent a comprehensive ocular examination, retinal nerve fiber layer optical coherence tomography scan, and visual field tests performed at baseline and after 3 months and 6 months, using OCCP and SAP in clinic. Results The current study was carried out in 168 eyes of 87 patients at baseline, 133 eyes of 69 patients at 3 months, and 121 eyes of 63 patients at 6 months. At baseline, OCCP mean deviation (MD) (R2 = 0.804, p < 0.001) and visual index (VI) (R2 = 0.892, p < 0.001) were strongly correlated with SAP MD and visual field index (VFI) respectively. There was strong agreement and correlation between MD and VI/VFI for SAP and OCCP on repeated testing after 6 months. At 6 months AUC of SAP VFI (0.79) was superior to AUC of OCCP VI (0.67, p = 0.036); otherwise there was no difference in AUC of MD or VI/VFI at baseline, 3 and 6 months, when comparing OCCP and SAP. Conclusion OCCP parameters are significantly correlated with those of SAP. OCCP has the potential to provide a complementary role to SAP in glaucoma screening and monitoring.
Collapse
Affiliation(s)
- Tung Thanh Hoang
- Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
- Ophthalmology Unit, Hanoi Medical University Hospital, Hanoi, Vietnam
| | - Tung Quoc Mai
- Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
| | - Dung Thi Pham
- Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
| | - Xuan Thi Nguyen
- Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
| | - Duc-Anh Nguyen
- Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
| | - Diu Thi Vu
- Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
| | - Hien Thi Hoang
- Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
| | - Menus Nkurunziza
- Centre for Mathematics and Physics, University of Burundi, Bujumbura, Burundi
| | - Deus Bigirimana
- University of Melbourne, Department of Surgery, Melbourne, Victoria, Australia
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia
- Centre for Eye Research Australia, The Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia
| | - Simon Edward Skalicky
- University of Melbourne, Department of Surgery, Melbourne, Victoria, Australia
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
4
|
Meyerov J, Chen Y, Busija L, Green C, Skalicky SE. Repeatability of Online Circular Contrast Perimetry Compared to Standard Automated Perimetry. J Glaucoma 2024; 33:505-515. [PMID: 38595156 DOI: 10.1097/ijg.0000000000002384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 02/16/2024] [Indexed: 04/11/2024]
Abstract
PRCIS Online circular contrast perimetry provides visual field assessment on any computer or tablet with no extra hardware. It has good test repeatability and reliability that is comparable with standard automated perimetry. It holds promise for use in disease screening and surveillance to expand the provision of glaucoma care. PURPOSE To evaluate the repeatability of online circular contrast perimetry (OCCP) compared to standard automated perimetry (SAP) in normal participants and patients with stable glaucoma over 18 weeks. METHODS Thirty-six participants (13 normal controls and 23 patients with open angle glaucoma) were recruited. OCCP and SAP perimetry tests were performed twice at baseline, then at 6, 12, and 18 weeks. Global perimetric indices were compared between perimetry types and analyzed for short-term and intermediate-term repeatability. RESULTS There were no statistically significant changes over time for both OCCP and SAP across all groups for mean deviation (MD), pattern standard deviation, and visual index/visual field index ( P >0.05). Test-retest intraclass correlation coefficients (ICCs) for OCCP MD were excellent at baseline (0.98, 95% CI: 0.89-0.99) and good at 18 weeks (0.88, 95% CI: 0.51-0.98). SAP test-retest ICCs were excellent at baseline (0.94, 95% CI: 0.70-0.99) and 18 weeks (0.97, 95% CI: 0.84-0.99). Inter-test ICCs were good, ranging from 0.84 to 0.87. OCCP testing time was shorter than SAP (5:29 ± 1:24 vs. 6:00 ± 1:05, P <0.001). OCCP had similar false-positive (3.84 ± 3.32 vs. 3.66 ± 4.53, P =0.48) but lower false-negative (0.73 ± 1.52 vs. 4.48 ± 5.00, P <0.001) and fixation loss responses (0.91 ± 1.32 vs. 2.02 ± 2.17, P <0.001). CONCLUSIONS OCCP allows visual field assessment on any computer screen with no additional hardware. It demonstrated good repeatability and reliability with similar performance indices to SAP in both the short term and intermediate term. OCCP has the potential to be utilized as a glaucoma screening and surveillance tool for in-clinic and at-home testing, expanding the provision of care.
Collapse
Affiliation(s)
- Joshua Meyerov
- Department of Ophthalmology, The Alfred Hospital, Alfred Health
| | - Yang Chen
- Department of Surgery Ophthalmology, University of Melbourne
| | - Lazar Busija
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Catherine Green
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| |
Collapse
|
5
|
Chen YX, Meyerov J, Skalicky SE. Online Circular Contrast Perimetry via a Web-Application: Establishing a Normative Database for Central 10-Degree Perimetry. Clin Ophthalmol 2024; 18:201-213. [PMID: 38269363 PMCID: PMC10807269 DOI: 10.2147/opth.s440964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 12/23/2023] [Indexed: 01/26/2024] Open
Abstract
Purpose To establish a normative database using a central 10-degree grid pattern for the online circular contrast perimetry (OCCP) application. Participants Fifty participants with mean age 65 ± 13 years were selected for this study. One eye from each participant that met inclusion criteria was randomly included in the cohort. Methods The web-application delivered online 52-loci perimetry in a central 10-degree pattern using circular flickering targets. These targets consist of concentric sinusoidal alternating contrast rings. Users were guided by the application to the correct viewing distance and head position using in-built blind spot localization and webcam monitoring. A spinning golden star was used as the fixation target and patients performed the test in a darkened room following standard automated perimetry (SAP). Results The reliability rates and global indices for OCCP were similar to SAP. OCCP mean sensitivity reduced with age at a similar rate to SAP. Mean sensitivity per loci of 10-degree OCCP was greater than SAP by 1.24 log units (95% CI 1.23 to 1.26) and obeyed a physiological hill of vision. Small differences existed in mean sensitivities between OCCP and SAP which increased with increasing spot eccentricity. Mean deviation (MD) displayed good agreement between the two tests. Conclusion Central 10-degree online circular contrast perimetry via a computer-based application has comparable perimetric results to standard automated perimetry in a normal cohort.
Collapse
Affiliation(s)
- Yang X Chen
- St Vincent’s Hospital Clinical School, University of Melbourne, Melbourne, VIC, Australia
| | - Joshua Meyerov
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
- Glaucoma Investigation and Research Unit, the Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| |
Collapse
|
6
|
Goliskina V, Ceple I, Kassaliete E, Serpa E, Truksa R, Svede A, Krauze L, Fomins S, Ikaunieks G, Krumina G. The Effect of Stimulus Contrast and Spatial Position on Saccadic Eye Movement Parameters. Vision (Basel) 2023; 7:68. [PMID: 37873896 PMCID: PMC10594497 DOI: 10.3390/vision7040068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 10/05/2023] [Accepted: 10/16/2023] [Indexed: 10/25/2023] Open
Abstract
(1) Background: Saccadic eye movements are rapid eye movements aimed to position the object image on the central retina, ensuring high-resolution data sampling across the visual field. Although saccadic eye movements are studied extensively, different experimental settings applied across different studies have left an open question of whether and how stimulus parameters can affect the saccadic performance. The current study aims to explore the effect of stimulus contrast and spatial position on saccadic eye movement latency, peak velocity and accuracy measurements. (2) Methods: Saccadic eye movement targets of different contrast levels were presented at four different spatial positions. The eye movements were recorded with a Tobii Pro Fusion video-oculograph (250 Hz). (3) Results: The results demonstrate a significant effect of stimulus spatial position on the latency and peak velocity measurements at a medium grey background, 30 cd/m2 (negative and positive stimulus polarity), light grey background, 90 cd/m2 (negative polarity), and black background, 3 cd/m2 (positive polarity). A significant effect of the stimulus spatial position was observed on the accuracy measurements when the saccadic eye movement stimuli were presented on a medium grey background (negative polarity) and on a black background. No significant effect of stimulus contrast was observed on the peak velocity measurements under all conditions. A significant stimulus contrast effect on latency and accuracy was observed only on a light grey background. (4) Conclusions: The best saccadic eye movement performance (lowest latency, highest peak velocity and accuracy measurements) can be observed when the saccades are oriented to the right and left from the central fixation point. Furthermore, when presenting the stimulus on a light grey background, a very low contrast stimuli should be considered carefully.
Collapse
Affiliation(s)
- Viktorija Goliskina
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| | - Ilze Ceple
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| | - Evita Kassaliete
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| | - Evita Serpa
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| | - Renars Truksa
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| | - Aiga Svede
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| | - Linda Krauze
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| | - Sergejs Fomins
- Institute of Solid State Physics, University of Latvia, LV-1063 Riga, Latvia;
| | - Gatis Ikaunieks
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| | - Gunta Krumina
- Department of Optometry and Vision Science, Faculty of Physics, Mathematics and Optometry, University of Latvia, LV-1586 Riga, Latvia; (E.K.); (E.S.); (R.T.); (A.S.); (L.K.); (G.I.); (G.K.)
| |
Collapse
|
7
|
Meyerov J, Deng Y, Busija L, Bigirimana D, Skalicky SE. Online Circular Contrast Perimetry: A Comparison to Standard Automated Perimetry. Asia Pac J Ophthalmol (Phila) 2023; 12:4-15. [PMID: 36706329 DOI: 10.1097/apo.0000000000000589] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 10/30/2022] [Indexed: 01/29/2023] Open
Abstract
PURPOSE The aim was to validate and compare the diagnostic accuracy of a novel 24-degree, 52-loci online circular contrast perimetry (OCCP) application to standard automated perimetry (SAP). DESIGN Prospective cohort study. METHODS Two hundred and twenty participants (125 normal controls, 95 open angle glaucoma patients) were included. Agreement, correlation, sensitivity, specificity, and area under receiver operating curves (AUC) were compared for parameters of OCCP, SAP, and optical coherence tomography (OCT) for the retinal nerve fiber layer and macular ganglion cell complex inner plexiform layer. RESULTS Pointwise sensitivity for OCCP was greater than SAP by 1.02 log units (95% CI: 0.95-1.08); 95% limits of agreement 0.860 to 1.17. Correlation and agreement for global indices and regional zones between OCCP and SAP were strong. OCCP mean deviation (MD) AUC was 0.885±0.08, similar to other instruments' parameters with the highest AUC: SAP MD (0.851±0.08), OCT retinal nerve fiber layer inferior thickness (0.908±0.07), OCT ganglion cell complex inner plexiform layer inferior thickness (0.849±0.08), P>0.05. At best cutoff, OCCP MD sensitivity/specificity were comparable to SAP MD (90/74 vs 94/65%). CONCLUSIONS OCCP demonstrates similar perimetric sensitivities to SAP and similar AUC to SAP and OCT in distinguishing glaucoma patients from controls. OCCP holds promise as a glaucoma surveillance and screening tool, with the potential to be utilized for in-clinic and at-home perimetry and expand community testing.
Collapse
Affiliation(s)
- Joshua Meyerov
- St Vincent's Hospital Clinical School, University of Melbourne, Melbourne, Vic., Australia
| | - Yuanchen Deng
- St Vincent's Hospital Clinical School, University of Melbourne, Melbourne, Vic., Australia
| | - Lazar Busija
- Glaucoma Investigation and Research Unit, the Royal Victorian Eye and Ear Hospital, Melbourne, Vic., Australia
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, Vic., Australia
| | - Deus Bigirimana
- Glaucoma Investigation and Research Unit, the Royal Victorian Eye and Ear Hospital, Melbourne, Vic., Australia
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, Vic., Australia
| | - Simon E Skalicky
- Glaucoma Investigation and Research Unit, the Royal Victorian Eye and Ear Hospital, Melbourne, Vic., Australia
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, Vic., Australia
| |
Collapse
|
8
|
McDonald MA, Stevenson CH, Kersten HM, Danesh-Meyer HV. Eye Movement Abnormalities in Glaucoma Patients: A Review. Eye Brain 2022; 14:83-114. [PMID: 36105571 PMCID: PMC9467299 DOI: 10.2147/eb.s361946] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 07/09/2022] [Indexed: 11/23/2022] Open
Abstract
Glaucoma is a common condition that relies on careful clinical assessment to diagnose and determine disease progression. There is growing evidence that glaucoma is associated not only with loss of retinal ganglion cells but also with degeneration of cortical and subcortical brain structures associated with vision and eye movements. The effect of glaucoma pathophysiology on eye movements is not well understood. In this review, we examine the evidence surrounding altered eye movements in glaucoma patients compared to healthy controls, with a focus on quantitative eye tracking studies measuring saccades, fixation, and optokinetic nystagmus in a range of visual tasks. The evidence suggests that glaucoma patients have alterations in several eye movement domains. Patients exhibit longer saccade latencies, which worsen with increasing glaucoma severity. Other saccadic abnormalities include lower saccade amplitude and velocity, and difficulty inhibiting reflexive saccades. Fixation is pathologically altered in glaucoma with reduced stability. Optokinetic nystagmus measures have also been shown to be abnormal. Complex visual tasks (eg reading, driving, and navigating obstacles), integrate these eye movements and result in behavioral adaptations. The review concludes with a summary of the evidence and recommendations for future research in this emerging field.
Collapse
Affiliation(s)
- Matthew A McDonald
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Clark H Stevenson
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand
| | - Hannah M Kersten
- School of Optometry and Vision Science, University of Auckland, Auckland, New Zealand.,Eye Institute, Auckland, New Zealand
| | - Helen V Danesh-Meyer
- Department of Ophthalmology, University of Auckland, Auckland, New Zealand.,Eye Institute, Auckland, New Zealand
| |
Collapse
|
9
|
Mahanama B, Jayawardana Y, Rengarajan S, Jayawardena G, Chukoskie L, Snider J, Jayarathna S. Eye Movement and Pupil Measures: A Review. FRONTIERS IN COMPUTER SCIENCE 2022. [DOI: 10.3389/fcomp.2021.733531] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Our subjective visual experiences involve complex interaction between our eyes, our brain, and the surrounding world. It gives us the sense of sight, color, stereopsis, distance, pattern recognition, motor coordination, and more. The increasing ubiquity of gaze-aware technology brings with it the ability to track gaze and pupil measures with varying degrees of fidelity. With this in mind, a review that considers the various gaze measures becomes increasingly relevant, especially considering our ability to make sense of these signals given different spatio-temporal sampling capacities. In this paper, we selectively review prior work on eye movements and pupil measures. We first describe the main oculomotor events studied in the literature, and their characteristics exploited by different measures. Next, we review various eye movement and pupil measures from prior literature. Finally, we discuss our observations based on applications of these measures, the benefits and practical challenges involving these measures, and our recommendations on future eye-tracking research directions.
Collapse
|
10
|
Agrawal Y, Van de Berg R, Wuyts F, Walther L, Magnusson M, Oh E, Sharpe M, Strupp M. Presbivestibulopatía: criterios diagnósticos. Documento de consenso del Comité de Clasificación de la Bárány Society. ACTA OTORRINOLARINGOLOGICA ESPANOLA 2022. [DOI: 10.1016/j.otorri.2021.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
11
|
Ramzaoui H, Faure S, Spotorno S. EXPRESS: Age-related differences when searching in a real environment: The use of semantic contextual guidance and incidental object encoding. Q J Exp Psychol (Hove) 2021; 75:1948-1958. [PMID: 34816760 DOI: 10.1177/17470218211064887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Visual search is a crucial, everyday activity that declines with aging. Here, referring to the environmental support account, we hypothesized that semantic contextual associations between the target and the neighboring objects (e.g., a teacup near a tea bag and a spoon), acting as external cues, may counteract this decline. Moreover, when searching for a target, viewers may encode information about the co-present distractor objects, by simply looking at them. In everyday life, where viewers often search for several targets within the same environment, such distractor objects may often become targets of future searches. Thus, we examined whether incidentally fixating a target during previous trials, when it was a distractor, may also modulate the impact of aging on search performance. We used everyday object arrays on tables in a real room, where healthy young and older adults had to search sequentially for multiple objects across different trials within the same array. We showed that search was quicker: (1) in young than older adults, (2) for targets surrounded by semantically associated objects than unassociated objects, but only in older adults, and (3) for incidentally fixated targets than for targets that were not fixated when they were distractors, with no differences between young and older adults. These results suggest that older viewers use both environmental support based on object semantic associations and object information incidentally encoded to enhance efficiency of real-world search, even in relatively simple environments. This reduces, but does not eliminate, search decline related to aging.
Collapse
Affiliation(s)
| | | | - Sara Spotorno
- School of Psychology, Keele University, United Kingdom 4212
| |
Collapse
|
12
|
Bedggood P, Prea SM, Kong YXG, Vingrys AJ. Scaling the size of perimetric stimuli reduces variability and returns constant thresholds across the visual field. J Vis 2021; 21:2. [PMID: 34617957 PMCID: PMC8504188 DOI: 10.1167/jov.21.11.2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The conventional stimulus for standard automated perimetry is fixed in size, giving elevated contrast thresholds and reduced test reliability in the periphery. Here, we test the hypothesis that appropriate scaling of the size of perimetric stimuli will return fixed thresholds and reduced variability across the visual field. We derived frequency-of-seeing (FOS) curves in five healthy subjects at central (3 degrees) and peripheral (27 degrees) locations with a method of constant stimuli (MOCS) using a desktop LCD display. FOS curves for a Goldmann III (GIII) stimulus were compared with those for size scaled spots. To consider clinical translation, we tested a further five healthy subjects (22–24 years) with the Melbourne Rapid Fields (MRF) tablet perimeter at several locations spanning 1 degree to 25 degrees from fixation, deriving FOS curves (MOCS) and also conducting repeated adaptive clinical thresholding to assess intra- and interobserver variability. We found that GIII contrast thresholds were significantly elevated in the periphery compared with the parafovea, with concomitant reduction of FOS slope. Using appropriately size scaled spots, threshold and slope differences between these locations were significantly reduced. FOS data collected with the tablet perimeter confirmed that size scaling confers broad equivalence of the shape of the FOS curve across the visual field. Repeated adaptive thresholding with size scaled stimuli gave relatively constant intra-observer variability across the visual field, which compares favorably with published normative data obtained with the GIII stimulus. The reduced variability will improve signal-to-noise ratio for correct classification of normal visual field test results, whereas the lower contrast thresholds yield greater dynamic range, which should improve the ability to reliably monitor moderate defects.
Collapse
Affiliation(s)
- Phillip Bedggood
- Department of Optometry & Vision Sciences, University of Melbourne, Parkville, Victoria, Australia.,
| | - Selwyn Marc Prea
- Department of Optometry & Vision Sciences, University of Melbourne, Parkville, Victoria, Australia.,
| | - Yu Xiang George Kong
- Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Centre for Eye Research Australia, East Melbourne, Australia.,
| | - Algis J Vingrys
- Department of Optometry & Vision Sciences, University of Melbourne, Parkville, Victoria, Australia.,
| |
Collapse
|
13
|
Thepass G, Lemij HG, Vermeer KA, van der Steen J, Pel JJM. Slowed Saccadic Reaction Times in Seemingly Normal Parts of Glaucomatous Visual Fields. Front Med (Lausanne) 2021; 8:679297. [PMID: 34513866 PMCID: PMC8426641 DOI: 10.3389/fmed.2021.679297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 08/02/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose: In eye movement perimetry, peripheral stimuli are confirmed by goal-directed eye movements toward the stimulus. The saccadic reaction time (SRT) is regarded as an index of visual field responsiveness, whereas in standard automated perimetry (SAP), the visual field sensitivity is tested. We investigated the relation between visual field sensitivity and responsiveness in corresponding locations of the visual field in healthy controls and in patients with mild, moderate and advanced glaucoma. Materials and Methods: Thirty-four healthy control subjects and 42 glaucoma patients underwent a 54-point protocol in eye movement perimetry (EMP) and a 24-2 SITA standard protocol in a Humphrey Field Analyzer. The visual field points were stratified by total deviation sensitivity loss in SAP into 6 strata. A generalized linear mixed model was applied to determine the influence of the various factors. Results: The generalized linear mixed model showed that the mean SRT increased with increasing glaucoma severity, from 479 ms in the control eyes to 678 ms in the eyes of patients with advanced glaucoma (p < 0.001). Mean SRTs significantly increased with increasing SAP sensitivity loss. Even at the locations where no sensitivity loss was detected by SAP (total deviation values greater or equal than 0 dB), we found lengthened SRTs in mild, moderate and advanced glaucoma compared to healthy controls (p < 0.05) and in moderate and advanced glaucoma compared to mild glaucoma (p < 0.05). At locations with total deviation values between 0 and −3 dB, −3 and −6 dB and −6 and −12 dB, we found similar differences. Conclusions: The lengthened SRT in areas with normal retinal sensitivities in glaucomatous eyes, i.e., planning and execution of saccades to specific locations, precede altered sensory perception as assessed with SAP. Better understanding of altered sensory processing in glaucoma might allow earlier diagnosis of emerging glaucoma.
Collapse
Affiliation(s)
- Gijs Thepass
- Vestibular and Ocular Motor Research Group, Department of Neuroscience, Erasmus MC, Rotterdam, Netherlands.,Rotterdam Ophthalmic Institute, Rotterdam, Netherlands
| | - Hans G Lemij
- Glaucoma Service, Rotterdam Eye Hospital, Rotterdam, Netherlands
| | | | - Johannes van der Steen
- Vestibular and Ocular Motor Research Group, Department of Neuroscience, Erasmus MC, Rotterdam, Netherlands.,Royal Dutch Visio, Huizen, Netherlands
| | - Johan J M Pel
- Vestibular and Ocular Motor Research Group, Department of Neuroscience, Erasmus MC, Rotterdam, Netherlands
| |
Collapse
|
14
|
Wong EC, Pasquesi L, Steenerson KK, Sharon JD. A Broader View of Video Head Impulse Tests-Reframing Windows. JAMA Otolaryngol Head Neck Surg 2021; 147:215-218. [PMID: 33270083 DOI: 10.1001/jamaoto.2020.4135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Emily C Wong
- University of California, San Francisco, San Francisco
| | | | | | | |
Collapse
|
15
|
孙 勍, 张 清, 彭 新, 陈 元, 孙 悍. [Clinical strategies to prevent falls]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2021; 35:108-111. [PMID: 33540989 PMCID: PMC10127870 DOI: 10.13201/j.issn.2096-7993.2021.02.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Indexed: 06/12/2023]
Abstract
With the aging of population structure, the age-related balance dysfunction increases gradually, and the injuries related fall are increasing, which cause a serious social and economic burden. In addition, dizziness or vertigo is very common clinically, and these patients also have a higher risk of falling. In order to reduce the incidence of falls, targeted prevention measures are urgently needed. In this paper, the risk assessment, preventive measures and rehabilitation strategies of falls are systematically expounded, it is hoped that it will be helpful for the prevention and treatment of falls.
Collapse
Affiliation(s)
- 勍 孙
- 解放军总医院耳鼻咽喉头颈外科医学部 解放军总医院第三医学中心耳鼻咽喉头颈外科 国家耳鼻咽喉疾病临床医学研究中心(北京,100039)
| | - 清华 张
- 解放军总医院耳鼻咽喉头颈外科医学部 解放军总医院第三医学中心耳鼻咽喉头颈外科 国家耳鼻咽喉疾病临床医学研究中心(北京,100039)
| | | | - 元星 陈
- 解放军总医院耳鼻咽喉头颈外科医学部 解放军总医院第三医学中心耳鼻咽喉头颈外科 国家耳鼻咽喉疾病临床医学研究中心(北京,100039)
| | - 悍军 孙
- 解放军总医院耳鼻咽喉头颈外科医学部 解放军总医院第三医学中心耳鼻咽喉头颈外科 国家耳鼻咽喉疾病临床医学研究中心(北京,100039)
| |
Collapse
|
16
|
Salience-based object prioritization during active viewing of naturalistic scenes in young and older adults. Sci Rep 2020; 10:22057. [PMID: 33328485 PMCID: PMC7745017 DOI: 10.1038/s41598-020-78203-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 11/18/2020] [Indexed: 11/21/2022] Open
Abstract
Whether fixation selection in real-world scenes is guided by image salience or by objects has been a matter of scientific debate. To contrast the two views, we compared effects of location-based and object-based visual salience in young and older (65 + years) adults. Generalized linear mixed models were used to assess the unique contribution of salience to fixation selection in scenes. When analysing fixation guidance without recurrence to objects, visual salience predicted whether image patches were fixated or not. This effect was reduced for the elderly, replicating an earlier finding. When using objects as the unit of analysis, we found that highly salient objects were more frequently selected for fixation than objects with low visual salience. Interestingly, this effect was larger for older adults. We also analysed where viewers fixate within objects, once they are selected. A preferred viewing location close to the centre of the object was found for both age groups. The results support the view that objects are important units of saccadic selection. Reconciling the salience view with the object view, we suggest that visual salience contributes to prioritization among objects. Moreover, the data point towards an increasing relevance of object-bound information with increasing age.
Collapse
|
17
|
Eklöf M, Asp F, Berninger E. Sound localization latency in normal hearing and simulated unilateral hearing loss. Hear Res 2020; 395:108011. [PMID: 32792116 DOI: 10.1016/j.heares.2020.108011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Revised: 05/14/2020] [Accepted: 05/28/2020] [Indexed: 10/24/2022]
Abstract
Directing gaze towards auditory events is a natural behavior. In addition to the well-known accuracy of auditory elicited gaze responses for normal binaural listening, their latency is a measure of possible clinical interest and methodological importance. The aim was to develop a clinically feasible method to assess sound localization latency (SLL), and to study SLL as a function of simulated unilateral hearing loss (SUHL) and the relationship with accuracy. Eight healthy and normal-hearing adults (18-40 years) participated in this study. Horizontal gaze responses, recorded by non-invasive corneal reflection eye-tracking, were obtained during azimuthal shifts (24 trials) of a 3-min continuous auditory stimulus. In each trial, a sigmoid function was fitted to gaze samples. Latency was estimated by the abscissa corresponding to 50% of the arctangent amplitude. SLL was defined as the mean latency across trials. SLL was measured in normal-hearing and simulated SUHL conditions (SUHL30 and SUHL43: mean threshold of 30 dB HL and 43 dB HL across 0.5, 1, 2, and 4 kHz). In the normal-hearing condition, the mean ± SD SLL was 280 ± 40 ms (n = 8) with a test-retest SD = 20 ms. A linear mixed model showed a statistically significant effect of listening condition on SLL. The SUHL30 and SUHL43 conditions revealed a mean SLL of 370 ± 49 ms and 540 ± 120 ms, respectively. Repeated measures correlation analysis showed a clear relationship between SLL and the average sound localization accuracy (R2 = 0.94). The rapid and reliable method to obtain SLL may be an important clinical tool for evaluation of binaural processing. Future studies in clinical cohorts are needed to assess whether SLL may reveal information about binaural processing abilities beyond that afforded by sound localization accuracy.
Collapse
Affiliation(s)
- Martin Eklöf
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden; Department of ENT, Section of Hearing Implants, Karolinska University Hospital, Stockholm, Sweden.
| | - Filip Asp
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden; Department of ENT, Section of Hearing Implants, Karolinska University Hospital, Stockholm, Sweden
| | - Erik Berninger
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden; Department of Audiology and Neurotology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
18
|
Visual Field Plots: A Comparison Study Between Standard Automated Perimetry and Eye Movement Perimetry. J Glaucoma 2020; 29:351-361. [PMID: 32108671 DOI: 10.1097/ijg.0000000000001477] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
PRéCIS:: This eye movement perimetry (EMP) study describes the development of saccadic reaction time (SRT)-based visual field plots, which could effectively display the presence, location, and extent of glaucomatous defects and support clinical decision-making. PURPOSE EMP is capable of discriminating normal from glaucomatous visual field defects on the basis of average delays in SRTs. To classify the presence and extent of age-corrected visual field defects, it is required to create SRT-based probability maps. AIM The aim of this study was to create visual field probability plots based on SRTs and to evaluate their clinical applicability by 2 glaucoma specialists. MATERIALS AND METHODS The development phase included 95 controls segregated into 5 age-bins to estimate normative limits of SRT. Next, for the testing phase, a set of 28 healthy subjects and 24 glaucoma patients were recruited who underwent standard automated perimetry (SAP) and EMP visual field testing. Fifty-two SAP and EMP plots were presented to 2 glaucoma specialists to classify them as normal or abnormal and to identify the defect location and pattern as 1 or more of 7 predefined categories. RESULTS The glaucoma specialists showed a sensitivity of 100% and a specificity of 93% and 96% for identifying normal versus abnormal visual field. For specialists 1 and 2, 85% and 92%, respectively, of EMP reports were assigned to the same category as SAP. The reports that did not agree with SAP were graded to a higher defect pattern. The intermethod agreement for specialists 1 and 2 was κ 0.92 and 0.96, respectively. CONCLUSION SRT-based visual field probability plots provided a comprehensive summary of an individual's visual field status and showed comparable clinical applicability to that of SAP plots.
Collapse
|
19
|
Agrawal Y, Van de Berg R, Wuyts F, Walther L, Magnusson M, Oh E, Sharpe M, Strupp M. Presbyvestibulopathy: Diagnostic criteria Consensus document of the classification committee of the Bárány Society. J Vestib Res 2019; 29:161-170. [PMID: 31306146 PMCID: PMC9249286 DOI: 10.3233/ves-190672] [Citation(s) in RCA: 93] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
This paper describes the diagnostic criteria for presbyvestibulopathy (PVP) by the Classification Committee of the Bárány Society. PVP is defined as a chronic vestibular syndrome characterized by unsteadiness, gait disturbance, and/or recurrent falls in the presence of mild bilateral vestibular deficits, with findings on laboratory tests that are between normal values and thresholds established for bilateral vestibulopathy. The diagnosis of PVP is based on the patient history, bedside examination and laboratory evaluation. The diagnosis of PVP requires bilaterally reduced function of the vestibulo-ocular reflex (VOR). This can be diagnosed for the high frequency range of the VOR with the video-HIT (vHIT); for the middle frequency range with rotary chair testing; and for the low frequency range with caloric testing. For the diagnosis of PVP, the horizontal angular VOR gain on both sides should be < 0.8 and > 0.6, and/or the sum of the maximal peak velocities of the slow phase caloric-induced nystagmus for stimulation with warm and cold water on each side should be < 25°/s and > 6°/s, and/or the horizontal angular VOR gain should be > 0.1 and < 0.3 upon sinusoidal stimulation on a rotatory chair. PVP typically occurs along with other age-related deficits of vision, proprioception, and/or cortical, cerebellar and extrapyramidal function which also contribute and might even be required for the manifestation of the symptoms of unsteadiness, gait disturbance, and falls. These criteria simply consider the presence of these symptoms, along with documented impairment of vestibular function, in older adults.
Collapse
Affiliation(s)
- Yuri Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University, Baltimore, USA
| | - Raymond Van de Berg
- Department of Otolaryngology-Head and Neck Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Floris Wuyts
- Lab for Equilibrium Investigations and Aerospace, University of Antwerp, Antwerp, Belgium
| | - Leif Walther
- Department of Otorhinolaryngology-Head and Neck Surgery, University Medicine Mannheim, University of Heidelberg, Germany
| | - Mans Magnusson
- Department of Otorhinolaryngology, Lund University, Lund, Sweden
| | - Esther Oh
- Department of Geriatric Medicine and Gerontology, Johns Hopkins University, Baltimore, USA
| | | | - Michael Strupp
- Department of Neurology and German Center for Vertigo, Ludwig Maximilians University, Munich, Germany
| |
Collapse
|
20
|
Mazumdar D, Meethal NSK, Panday M, Asokan R, Thepass G, George RJ, van der Steen J, Pel JJM. Effect of Age, Sex, Stimulus Intensity, and Eccentricity on Saccadic Reaction Time in Eye Movement Perimetry. Transl Vis Sci Technol 2019; 8:13. [PMID: 31388465 PMCID: PMC6670042 DOI: 10.1167/tvst.8.4.13] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 05/13/2019] [Indexed: 11/24/2022] Open
Abstract
Purpose In eye movement perimetry (EMP), the extent of the visual field is tested by assessing the saccades using an eye tracker. The aim of the present study was to determine the effects of age and sex of the subjects, the eccentricity and intensity of the peripheral stimuli on saccadic reaction time (SRT), and the interaction between these parameters in healthy participants. Methods Healthy participants aged between 20 to 70 years underwent a complete ophthalmic examination and an EMP test. SRT was determined from detected peripheral stimuli of four intensity levels. A multilevel mixed-model analysis was used to verify the influence of subject and stimulus characteristics on SRT within the tested visual field. Results Ninety-five subjects (mean age 43.0 [15.0] years) were included. Age, stimulus intensity, and eccentricity had a statistically significant effect on SRT, not sex. SRTs were significantly faster with increasing stimulus intensity and decreasing eccentricity (P < 0.001). At the lowest stimulus intensity of 192 cd/m2, a significant interaction was found between age and eccentricity. Conclusions The current study demonstrated significant SRT dependence across the visual field measured up to 27°, irrespective of sex. The presented SRT values may serve as a first normative guide for EMP. Translational Relevance This report of SRT interaction can aid in refining its use as a measure of visual field responsiveness.
Collapse
Affiliation(s)
- Deepmala Mazumdar
- Vestibular and Ocular Motor Research Group, Department of Neuroscience, Erasmus MC, the Netherlands.,Medical and Vision Research Foundation, Chennai, India
| | - Najiya S Kadavath Meethal
- Vestibular and Ocular Motor Research Group, Department of Neuroscience, Erasmus MC, the Netherlands.,Medical and Vision Research Foundation, Chennai, India
| | - Manish Panday
- Medical and Vision Research Foundation, Chennai, India
| | - Rashima Asokan
- Medical and Vision Research Foundation, Chennai, India.,Elite School of Optometry, Chennai, India
| | - Gijs Thepass
- Vestibular and Ocular Motor Research Group, Department of Neuroscience, Erasmus MC, the Netherlands
| | | | - Johannes van der Steen
- Vestibular and Ocular Motor Research Group, Department of Neuroscience, Erasmus MC, the Netherlands.,Royal Dutch Visio, Huizen, the Netherlands
| | - Johan J M Pel
- Medical and Vision Research Foundation, Chennai, India
| |
Collapse
|
21
|
Cavazzana A, Röhrborn A, Garthus-Niegel S, Larsson M, Hummel T, Croy I. Sensory-specific impairment among older people. An investigation using both sensory thresholds and subjective measures across the five senses. PLoS One 2018; 13:e0202969. [PMID: 30148857 PMCID: PMC6110574 DOI: 10.1371/journal.pone.0202969] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 08/13/2018] [Indexed: 12/12/2022] Open
Abstract
Age-related sensory impairment is a slow and gradual progress, which affects multiple modalities. Two contradictory hypotheses exist about the age-related decline of sensory thresholds. The common factor theory assumes one underlying factor-which accounts for the loss of several sensory modalities simultaneously-and the specific factor theory predicts that the sensory decline is uncorrelated between different modalities. In this study, we aimed to explore whether (i) there is a common factor of sensory thresholds in older people, (ii) older people assume that sensory decline in one modality also affects other modalities, (iii) there is a relation between sensory threshold and the subjective assessment of sensory function. This was accomplished by collecting both threshold measures and self-reported ratings for smell, hearing, taste, vision, and touch function in a group of 104 older people (mean age: 67.2 years; SD: 9.85; range: 50-100 years). Results indicated that there was no common factor of sensory thresholds, hence an impairment in one modality did not necessarily imply a shortfall in other modalities. In contrast, our results suggested one or two common factor(s) for the participants' ratings. Participants who reported a diminished function in one sense tended to generalize this rating to the other senses as well. The correspondence between subjective ratings and sensory thresholds was relatively good for vision and audition, although no correlations were observed for the other domains. These findings have implications for clinicians, suggesting that subjective measures should be combined with sensory threshold measurements when evaluating sensory dysfunction. Also, these data convey a positive message for older people and their physicians by showing that loss in one sensory modality does not necessarily generalize to losses across all sensory modalities.
Collapse
Affiliation(s)
- Annachiara Cavazzana
- Smell & Taste Clinic, Department of Otorhinolaryngology, TU Dresden, Dresden, Germany
- Gösta Ekman Laboratory, Department of Psychology, Stockholm University, Stockholm, Sweden
| | - Anja Röhrborn
- Department of Psychotherapy and Psychosomatic Medicine, Faculty of Medicine of the Technische Universität Dresden, Dresden, Germany
| | - Susan Garthus-Niegel
- Department of Psychotherapy and Psychosomatic Medicine, Faculty of Medicine of the Technische Universität Dresden, Dresden, Germany
- Department of Child Health, Norwegian Institute of Public Health, Oslo, Norway
| | - Maria Larsson
- Gösta Ekman Laboratory, Department of Psychology, Stockholm University, Stockholm, Sweden
| | - Thomas Hummel
- Smell & Taste Clinic, Department of Otorhinolaryngology, TU Dresden, Dresden, Germany
| | - Ilona Croy
- Department of Psychotherapy and Psychosomatic Medicine, Faculty of Medicine of the Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
22
|
Development of a test grid using Eye Movement Perimetry for screening glaucomatous visual field defects. Graefes Arch Clin Exp Ophthalmol 2017; 256:371-379. [PMID: 29282563 PMCID: PMC5790865 DOI: 10.1007/s00417-017-3872-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 12/07/2017] [Accepted: 12/11/2017] [Indexed: 11/08/2022] Open
Abstract
Background Eye Movement Perimetry (EMP) uses Saccadic Eye Movement (SEM) responses for visual field evaluation. Previous studies have demonstrated significant delay in initiation of SEMs among glaucoma patients in comparison with healthy subjects. The aim of the current study was to develop an EMP-based screening grid to identify glaucomatous visual field defects. Methods An interactive test consisting of 36 locations and two stimulus contrasts (162 cd/m2 and 190 cd/m2 on a background of 140 cd/m2) was evaluated in 54 healthy subjects and 50 primary glaucoma patients. Each subject was presented a central fixation target combined with the random projection of Goldmann size III peripheral targets. Instructions were given to look at each peripheral target on detection and then re-fixate at the central fixation target while the saccades were assessed using an eye tracker. From each seen peripheral target, the Saccadic Reaction Time (SRT) was calculated for contrast level 162 cd/ m2. These values were used to plot Receiver Operating Characteristic (ROC) curves for each test locations and the Area Under the Curve (AUC) values were used to identify the locations with highest susceptibility to glaucomatous damage. Each stimulus location with an AUC less than 0.75 along with its mirrored test location around the horizontal axis were eliminated from the grid. Results The mean age was 48.1 ± 16.6 years and 50.0 ± 14.5 years for healthy subjects and glaucoma patients respectively. A significant increase of SRT values by 76.5% (p < 0.001) was found in glaucoma patients in comparison with the healthy subjects. From the ROC analysis, ten out of 36 locations meeting the cut-off criteria of AUC were eliminated resulting in a new grid containing 26 test locations. SRT values were significantly different (p < 0.05) between the healthy subjects and glaucoma irrespective of the grids used. Conclusions The present study resulted in a screening grid consisting of 26 locations predominantly testing nasal, superior and inferior areas of the visual field. An internal validation of the modified grid showed 90.4% of screening accuracy which makes it a potential approach for population based glaucoma screening. Electronic supplementary material The online version of this article (10.1007/s00417-017-3872-x) contains supplementary material, which is available to authorized users.
Collapse
|
23
|
Xie Y, Anson ER, Simonsick EM, Studenski SA, Agrawal Y. Compensatory Saccades Are Associated With Physical Performance in Older Adults: Data From the Baltimore Longitudinal Study of Aging. Otol Neurotol 2017; 38:373-378. [PMID: 28192379 PMCID: PMC5308452 DOI: 10.1097/mao.0000000000001301] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To determine whether compensatory saccade metrics observed in the video head impulse test, specifically saccade amplitude and latency, predict physical performance. STUDY DESIGN Cross-sectional analysis of the Baltimore Longitudinal Study of Aging, a prospective cohort study. SETTING National Institute on Aging Intramural Research Program Clinical Research Unit in Baltimore, Maryland. PATIENTS Community-dwelling older adults. INTERVENTION(S) Video head impulse testing was performed, and compensatory saccades and horizontal vestibulo-ocular reflex (VOR) gain were measured. Physical performance was assessed using the Short Physical Performance Battery (SPPB), which included the feet side-by-side, semitandem, tandem, and single-leg stance; repeated chair stands; and usual gait speed measurements. MAIN OUTCOME MEASURE(S) Compensatory saccade amplitude and latency, VOR gain, and SPPB performance. RESULTS In 183 participants who underwent vestibular and SPPB testing (mean age 71.8 yr; 53% females), both higher mean saccade amplitude (odds ratio [OR] =1.62, p = 0.010) and shorter mean saccade latency (OR = 0.88, p = 0.004) were associated with a higher odds of failing the tandem stand task. In contrast, VOR gain was not associated with any physical performance measure. CONCLUSION We observed in a cohort of healthy older adults that compensatory saccade amplitude and latency were associated with tandem stance performance. Compensatory saccade metrics may provide insights into capturing the impact of vestibular loss on physical function in older adults.
Collapse
Affiliation(s)
- Yanjun Xie
- Department of Otolaryngology—Head and Neck Surgery, Johns Hopkins University School of Medicine, 601 North Caroline Street, 6 Floor, Baltimore, Maryland 21287 United States
| | - Eric R. Anson
- Department of Otolaryngology—Head and Neck Surgery, Johns Hopkins University School of Medicine, 601 North Caroline Street, 6 Floor, Baltimore, Maryland 21287 United States
| | - Eleanor M. Simonsick
- Longitudinal Studies Section, Translational Gerontology Branch, National Institute on Aging, National Institute of Health, 251 Bayview Boulevard Suite 100, Baltimore, Maryland 21224 United States
| | - Stephanie A. Studenski
- Longitudinal Studies Section, Translational Gerontology Branch, National Institute on Aging, National Institute of Health, 251 Bayview Boulevard Suite 100, Baltimore, Maryland 21224 United States
| | - Yuri Agrawal
- Department of Otolaryngology—Head and Neck Surgery, Johns Hopkins University School of Medicine, 601 North Caroline Street, 6 Floor, Baltimore, Maryland 21287 United States
| |
Collapse
|
24
|
Erel H, Levy DA. Orienting of visual attention in aging. Neurosci Biobehav Rev 2016; 69:357-80. [DOI: 10.1016/j.neubiorev.2016.08.010] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2015] [Revised: 08/01/2016] [Accepted: 08/06/2016] [Indexed: 11/28/2022]
|
25
|
Gadkaree SK, Sun DQ, Li C, Lin FR, Ferrucci L, Simonsick EM, Agrawal Y. Does Sensory Function Decline Independently or Concomitantly with Age? Data from the Baltimore Longitudinal Study of Aging. J Aging Res 2016; 2016:1865038. [PMID: 27774319 PMCID: PMC5059583 DOI: 10.1155/2016/1865038] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Accepted: 09/06/2016] [Indexed: 11/17/2022] Open
Abstract
Objectives. To investigate whether sensory function declines independently or in parallel with age within a single individual. Methods. Cross-sectional analysis of Baltimore Longitudinal Study of Aging (BLSA) participants who underwent vision (visual acuity threshold), proprioception (ankle joint proprioceptive threshold), vestibular function (cervical vestibular-evoked myogenic potential), hearing (pure-tone average audiometric threshold), and Health ABC physical performance battery testing. Results. A total of 276 participants (mean age 70 years, range 26-93) underwent all four sensory tests. The function of all four systems declined with age. After age adjustment, there were no significant associations between sensory systems. Among 70-79-year-olds, dual or triple sensory impairment was associated with poorer physical performance. Discussion. Our findings suggest that beyond the common mechanism of aging, other distinct (nonshared) etiologic mechanisms may contribute to decline in each sensory system. Multiple sensory impairments influence physical performance among individuals in middle old-age (age 70-79).
Collapse
Affiliation(s)
- Shekhar K. Gadkaree
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Daniel Q. Sun
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Carol Li
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Frank R. Lin
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Luigi Ferrucci
- National Institute on Aging, National Institutes of Health, Baltimore, MD, USA
| | | | - Yuri Agrawal
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
26
|
Anson ER, Bigelow RT, Carey JP, Xue QL, Studenski S, Schubert MC, Weber KP, Agrawal Y. Aging Increases Compensatory Saccade Amplitude in the Video Head Impulse Test. Front Neurol 2016; 7:113. [PMID: 27486430 PMCID: PMC4947583 DOI: 10.3389/fneur.2016.00113] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Accepted: 07/05/2016] [Indexed: 11/16/2022] Open
Abstract
Objective Rotational vestibular function declines with age resulting in saccades as a compensatory mechanism to improve impaired gaze stability. Small reductions in rotational vestibulo-ocular reflex (VOR) gain that would be considered clinically normal have been associated with compensatory saccades. We evaluated whether compensatory saccade characteristics varied as a function of age, independent of semicircular canal function as quantified by VOR gain. Methods Horizontal VOR gain was measured in 243 participants age 27–93 from the Baltimore Longitudinal Study of Aging using video head impulse testing. Latency and amplitude of the first saccade (either covert – occurring during head impulse, or overt – occurring following head impulse) were measured for head impulses with compensatory saccades (n = 2230 head impulses). The relationship between age and saccade latency, as well as the relationship between age and saccade amplitude, were evaluated using regression analyses adjusting for VOR gain, gender, and race. Results Older adults (mean age 75.9) made significantly larger compensatory saccades relative to younger adults (mean age 45.0). In analyses adjusted for VOR gain, there was a significant association between age and amplitude of the first compensatory covert saccade (β = 0.015, p = 0.008). In analyses adjusted for VOR gain, there was a significant association between age and amplitude of the first compensatory overt saccade (β = 0.02, p < 0.001). Compensatory saccade latencies did not vary significantly by age. Conclusion We observed that aging increases the compensatory catch-up saccade amplitude in healthy adults after controlling for VOR gain. Size of compensatory saccades may be useful in addition to VOR gain for characterizing vestibular function in aging adults.
Collapse
Affiliation(s)
- Eric R Anson
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine , Baltimore, MD , USA
| | - Robin T Bigelow
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine , Baltimore, MD , USA
| | - John P Carey
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine , Baltimore, MD , USA
| | - Quan-Li Xue
- Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA; Center on Aging and Health, Johns Hopkins Medical Institutions, Baltimore, MD, USA
| | - Stephanie Studenski
- Longitudinal Studies Section, National Institute on Aging , Baltimore, MD , USA
| | - Michael C Schubert
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine , Baltimore, MD , USA
| | - Konrad P Weber
- Department of Neurology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; Department of Ophthalmology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Yuri Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine , Baltimore, MD , USA
| |
Collapse
|
27
|
Anson ER, Bigelow RT, Carey JP, Xue QL, Studenski S, Schubert MC, Agrawal Y. VOR Gain Is Related to Compensatory Saccades in Healthy Older Adults. Front Aging Neurosci 2016; 8:150. [PMID: 27445793 PMCID: PMC4919329 DOI: 10.3389/fnagi.2016.00150] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Accepted: 06/10/2016] [Indexed: 11/30/2022] Open
Abstract
Objective: Vestibulo-ocular reflex (VOR) gain is well-suited for identifying rotational vestibular dysfunction, but may miss partial progressive decline in age-related vestibular function. Since compensatory saccades might provide an alternative method for identifying subtle vestibular decline, we describe the relationship between VOR gain and compensatory saccades in healthy older adults. Methods: Horizontal VOR gain was measured in 243 subjects age 60 and older from the Baltimore Longitudinal Study of Aging using video head impulse testing (HIT). Saccades in each HIT were identified as either “compensatory” or “compensatory back-up,” i.e., same or opposite direction as the VOR response respectively. Saccades were also classified as “covert” (occurring during head movement) and “overt” (occurring after head movement). The relationship between VOR gain and percentage of HITs with saccades, as well as the relationship between VOR gain and saccade latency and amplitude, were evaluated using regression analyses adjusting for age, gender, and race. Results: In adjusted analyses, the percentage of HITs with compensatory saccades increased 4.5% for every 0.1 decrease in VOR gain (p < 0.0001). Overt compensatory saccade amplitude decreased 0.6° (p < 0.005) and latency increased 90 ms (p < 0.001) for every 0.1 increase in VOR gain. Covert back-up compensatory saccade amplitude increased 0.4° for every 0.1 increase in VOR gain. Conclusion: We observed significant relationships between VOR gain and compensatory saccades in healthy older adults. Lower VOR gain was associated with larger amplitude, shorter latency compensatory saccades. Compensatory saccades reflect underlying rotational vestibular hypofunction, and may be particularly useful at identifying partial vestibular deficits as occur in aging adults.
Collapse
Affiliation(s)
- Eric R Anson
- Department of Otolaryngology - Head and Neck Surgery, Johns Hopkins University School of Medicine Baltimore, MD, USA
| | - Robin T Bigelow
- Department of Otolaryngology - Head and Neck Surgery, Johns Hopkins University School of Medicine Baltimore, MD, USA
| | - John P Carey
- Department of Otolaryngology - Head and Neck Surgery, Johns Hopkins University School of Medicine Baltimore, MD, USA
| | - Qian-Li Xue
- Department of Medicine, Johns Hopkins University School of MedicineBaltimore, MD, USA; Center on Aging and Health, Johns Hopkins Medical InstitutionsBaltimore, MD, USA
| | - Stephanie Studenski
- Longitudinal Studies Section, National Institute on Aging Baltimore, MD, USA
| | - Michael C Schubert
- Department of Otolaryngology - Head and Neck Surgery, Johns Hopkins University School of Medicine Baltimore, MD, USA
| | - Yuri Agrawal
- Department of Otolaryngology - Head and Neck Surgery, Johns Hopkins University School of Medicine Baltimore, MD, USA
| |
Collapse
|
28
|
The Effect of Cataract on Eye Movement Perimetry. J Ophthalmol 2015; 2015:425067. [PMID: 26078873 PMCID: PMC4452848 DOI: 10.1155/2015/425067] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2015] [Revised: 04/28/2015] [Accepted: 05/01/2015] [Indexed: 01/19/2023] Open
Abstract
Purpose. To determine how different grades of cataract affect sensitivity threshold and saccadic reaction time (SRT) in eye movement perimetry (EMP). Methods. In EMP, the visual field is tested by assessing the saccades that a subject makes towards peripheral stimuli using an eye tracker. Forty-eight cataract patients underwent pre- and postoperative EMP examination in both eyes. The subjects had to fix a central stimulus presented on the eye tracker monitor and to look at any detected peripheral stimulus upon its appearance. A multilevel mixed model was used to determine the factors that affected the sensitivity threshold and the SRT as a function of cataract grade. Results. We found no effect of cataract severity (LOCS III grades I through IV) on SRT and the sensitivity thresholds. In cataract of LOCS III grade V, however, we found an increase by 27% and 21% (p < 0.001), respectively, compared to the SRT and the sensitivity threshold in LOCS III grade I. Eyes that underwent cataract surgery showed no change in mean SRTs and sensitivity thresholds after surgery in LOCS III grade IV and lower. Conclusion. The present study shows that EMP can be readily used in patients with cataract with LOCS III grade IV and below.
Collapse
|