1
|
Braun M, Saini C, Sun JA, Shen LQ. The Role of Optical Coherence Tomography Angiography in Glaucoma. Semin Ophthalmol 2024; 39:412-423. [PMID: 38643350 DOI: 10.1080/08820538.2024.2343049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 04/08/2024] [Accepted: 04/09/2024] [Indexed: 04/22/2024]
Abstract
Glaucoma is the leading cause of irreversible vision loss and comprises a group of chronic optic neuropathies characterized by progressive retinal ganglion cell (RGC) loss. Various etiologies, including impaired blood supply to the optic nerve, have been implicated for glaucoma pathogenesis. Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality for visualizing the ophthalmic microvasculature. Using blood flow as an intrinsic contrast agent, it distinguishes blood vessels from the surrounding tissue. Vessel density (VD) is mainly used as a metric for quantifying the ophthalmic microvasculature. The key anatomic regions for OCTA in glaucoma are the optic nerve head area including the peripapillary region, and the macular region. Specifically, VD of the superficial peripapillary and superficial macular microvasculature is reduced in glaucoma patients compared to unaffected subjects, and VD correlates with functional deficits measured by visual field (VF). This renders OCTA similar in diagnostic capabilities compared to structural retinal nerve fiber layer (RNFL) thickness measurements, especially in early glaucoma. Furthermore, in cases where RNFL thickness measurements are limited due to artifact or floor effect, OCTA technology can be used to evaluate and monitor glaucoma, such as in eyes with high myopia and eyes with advanced glaucoma. However, the clinical utility of OCTA in glaucoma management is limited due to the prevalence of imaging artifacts. Overall, OCTA can play a complementary role in structural OCT imaging and VF testing to aid in the diagnosis and monitoring of glaucoma.
Collapse
Affiliation(s)
- Maximilian Braun
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
- Department of Ophthalmology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Chhavi Saini
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| | - Jessica A Sun
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| | - Lucy Q Shen
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
2
|
Lommatzsch C, van Oterendorp C. Current Status and Future Perspectives of Optic Nerve Imaging in Glaucoma. J Clin Med 2024; 13:1966. [PMID: 38610731 PMCID: PMC11012267 DOI: 10.3390/jcm13071966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 03/16/2024] [Accepted: 03/20/2024] [Indexed: 04/14/2024] Open
Abstract
Being the primary site of degeneration, the optic nerve has always been the focus of structural glaucoma assessment. The technical advancements, mainly of optical coherence tomography (OCT), now allow for a very precise quantification of the optic nerve head and peripapillary retina morphology. By far the most commonly used structural optic nerve parameter is the thickness of the parapapillary retinal nerve fiber, which has great clinical utility but also suffers from significant limitations, mainly in advanced glaucoma. Emerging novel imaging technologies, such as OCT angiography, polarization-sensitive or visible-light OCT and adaptive optics, offer new biomarkers that have the potential to significantly improve structural glaucoma diagnostics. Another great potential lies in the processing of the data already available. Artificial intelligence does not only help increase the reliability of current biomarkers but can also integrate data from various imaging modalities and other clinical measures to increase diagnostic accuracy. And it can, in a more efficient way, draw information from available datasets, such as an OCT scan, compared to the current concept of biomarkers, which only use a fraction of the whole dataset.
Collapse
Affiliation(s)
- Claudia Lommatzsch
- Department of Ophthalmology, St. Franziskus Hospital, Hohenzollernring 74, 48145 Muenster, Germany
- Department of Ophthalmology, University of Luebeck, 23562 Luebeck, Germany
| | | |
Collapse
|
3
|
Chua J, Wong D, Yow AP, Tan B, Liu X, Ismail MB, Chin CWL, Lamoureux E, Husain R, Schmetterer L. Segregation of neuronal and vascular retinal damage in patients with hypertension and diabetes. Ann N Y Acad Sci 2024; 1531:49-59. [PMID: 38084081 DOI: 10.1111/nyas.15089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
This study aimed to examine the impact of diabetes and hypertension on retinal nerve fiber layer (RNFL) thickness components. Optical coherence tomography (OCT) measurements do not consider blood vessel contribution, which this study addressed. We hypothesized that diabetes and/or hypertension would lead to thinner RNFL versus controls due to the vascular component. OCT angiography was used to measure the RNFL in 121 controls, 50 diabetes patients, 371 hypertension patients, and 177 diabetes patients with hypertension. A novel technique separated the RNFL thickness into original (vascular component) and corrected (no vascular component) measurements. Diabetes-only (98 ± 1.7 µm; p = 0.002) and diabetes with hypertension (99 ± 0.8 µm; p = 0.001) patients had thinner original RNFL versus controls (102 ± 0.8 µm). No difference was seen between hypertension-only patients (101 ± 0.5 µm; p = 0.083) and controls. After removing the blood vessel component, diabetes/hypertension groups had thinner corrected RNFL versus controls (p = 0.024). Discrepancies in diabetes/hypertension patients were due to thicker retinal blood vessels within the RNFL thickness (p = 0.002). Our findings suggest that diabetes and/or hypertension independently contribute to neurodegenerative thinning of the RNFL, even in the absence of retinopathy. The differentiation of neuronal and vascular components in RNFL thickness measurements provided by the novel technique highlights the importance of considering vascular changes in individuals with these conditions.
Collapse
Affiliation(s)
- Jacqueline Chua
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
| | - Damon Wong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| | - Ai Ping Yow
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore
- Institute for Digital Molecular Analytics and Science (IDMxS), Singapore, Singapore
| | - Bingyao Tan
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore
| | - Xinyu Liu
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore
| | - Munirah Binte Ismail
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore
| | - Calvin Woon Loong Chin
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
- National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, Singapore
| | - Ecosse Lamoureux
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
| | - Rahat Husain
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
| | - Leopold Schmetterer
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore
- Department of Clinical Pharmacology, Medical University Vienna, Vienna, Austria
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| |
Collapse
|
4
|
Yow AP, Chua J, Tan B, Chong R, Nongpiur ME, Gupta P, Lamoureux E, Husain R, Schmetterer L, Wong D. Neurovascular segregation of the retinal nerve fiber layer in glaucoma. Ann N Y Acad Sci 2023; 1528:95-103. [PMID: 37571987 DOI: 10.1111/nyas.15043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/14/2023]
Abstract
The imaging data of one eye from 154 healthy and 143 glaucoma participants were acquired to evaluate the contributions of the neuronal and vascular components within the retinal nerve fiber layer (RNFL) for detecting glaucoma and modeling visual field loss through the use of optical coherence tomography (OCT) and OCT angiography. The neuronal and vascular components within the circumpapillary RNFL were independently evaluated. In healthy eyes, the neuronal component showed a stronger association with age (r = -0.52, p < 0.001) compared to measured RNFL thickness (r = -0.46, p < 0.001). Using the neuronal component alone improved detection of glaucoma (AUC: 0.890 ± 0.020) compared to measured RNFL thickness (AUC: 0.877 ± 0.021; χ2 = 5.54, p = 0.019). Inclusion of the capillary components with the sectoral neuronal component resulted in a significant improvement in glaucoma detection (AUC: 0.927 ± 0.015; χ2 = 15.34, p < 0.001). After adjusting for potential confounders, AUC increased to 0.952 ± 0.011. Results from modeling visual field loss in glaucoma eyes suggest that visual field losses associated with neuronal thinning were moderated in eyes with a larger capillary component. These findings suggest that segregation of the neurovascular components could help improve understanding of disease pathophysiology and affect disease management in glaucoma.
Collapse
Affiliation(s)
- Ai Ping Yow
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- Institute for Digital Molecular Analytics and Science (IDMxS), Singapore
| | - Jacqueline Chua
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Bingyao Tan
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore
| | - Rachel Chong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Monisha E Nongpiur
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Preeti Gupta
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Ecosse Lamoureux
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
| | - Rahat Husain
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Leopold Schmetterer
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| | - Damon Wong
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| |
Collapse
|
5
|
Sharif NA. Recently Approved Drugs for Lowering and Controlling Intraocular Pressure to Reduce Vision Loss in Ocular Hypertensive and Glaucoma Patients. Pharmaceuticals (Basel) 2023; 16:791. [PMID: 37375739 DOI: 10.3390/ph16060791] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Revised: 05/17/2023] [Accepted: 05/19/2023] [Indexed: 06/29/2023] Open
Abstract
Serious vision loss occurs in patients affected by chronically raised intraocular pressure (IOP), a characteristic of many forms of glaucoma where damage to the optic nerve components causes progressive degeneration of retinal and brain neurons involved in visual perception. While many risk factors abound and have been validated for this glaucomatous optic neuropathy (GON), the major one is ocular hypertension (OHT), which results from the accumulation of excess aqueous humor (AQH) fluid in the anterior chamber of the eye. Millions around the world suffer from this asymptomatic and progressive degenerative eye disease. Since clinical evidence has revealed a strong correlation between the reduction in elevated IOP/OHT and GON progression, many drugs, devices, and surgical techniques have been developed to lower and control IOP. The constant quest for new pharmaceuticals and other modalities with superior therapeutic indices has recently yielded health authority-approved novel drugs with unique pharmacological signatures and mechanism(s) of action and AQH drainage microdevices for effectively and durably treating OHT. A unique nitric oxide-donating conjugate of latanoprost, an FP-receptor prostaglandin (PG; latanoprostene bunod), new rho kinase inhibitors (ripasudil; netarsudil), a novel non-PG EP2-receptor-selective agonist (omidenepag isopropyl), and a form of FP-receptor PG in a slow-release intracameral implant (Durysta) represent the additions to the pharmaceutical toolchest to mitigate the ravages of OHT. Despite these advances, early diagnosis of OHT and glaucoma still lags behind and would benefit from further concerted effort and attention.
Collapse
Affiliation(s)
- Najam A Sharif
- Eye-APC Duke-NUS Medical School, Singapore 169856, Singapore
- Singapore Eye Research Institute, Singapore 169856, Singapore
- Department of Pharmacology and Neuroscience, University of North Texas Health Sciences Center, Fort Worth, TX 76107, USA
- Department of Pharmacy Sciences, Creighton University, Omaha, NE 68178, USA
- Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Texas Southern University, Houston, TX 77004, USA
- Imperial College of Science and Technology, St. Mary's Campus, London SW7 2BX, UK
- Institute of Ophthalmology, University College London, London WC1E 6BT, UK
| |
Collapse
|
6
|
Xu C, Saini C, Wang M, Devlin J, Wang H, Greenstein SH, Brauner SC, Shen LQ. Combined Model of OCT Angiography and Structural OCT Parameters to Predict Paracentral Visual Field Loss in Primary Open-Angle Glaucoma. Ophthalmol Glaucoma 2023; 6:255-265. [PMID: 36252920 PMCID: PMC10102259 DOI: 10.1016/j.ogla.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 09/13/2022] [Accepted: 10/10/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE To assess a model combining OCT angiography (OCTA) and OCT parameters to predict the severity of paracentral visual field (VF) loss in primary open-angle glaucoma (POAG). DESIGN Cross-sectional study. PARTICIPANTS Forty-four patients with POAG and 42 control subjects underwent OCTA and OCT imaging with a swept-source OCT device. METHODS The circumpapillary microvasculature was quantified for vessel density (cpVD) and flow (cpFlow) after delineation of Bruch's membrane opening and removal of large vessels. Retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening-minimum rim width (BMO-MRW) were measured from structural OCT. Paracentral total deviation (PaTD) was defined as the average of the total deviation values within the central 10 degrees on Humphrey VF testing (24-2) for upper and lower hemifields. The OCT and OCTA parameters were measured in the affected hemisphere corresponding to the hemifield with lower PaTD for POAG patients. Models were created to predict affected PaTD based on RNFLT alone; RNFLT and BMO-MRW; OCTA alone; or RNFLT, BMO-MRW and OCTA parameters. The models were compared using coefficient of determination (r2) and Bayesian information criterion (BIC) score. Bayesian information criterion decrease of ≥6 indicates strong evidence for model improvement. MAIN OUTCOME MEASURES Performance of models containing OCT and OCTA parameters in predicting PaTD. RESULTS Patients with POAG and controls were similar in age and sex (65.9 ± 9.5 years and 38.4% male overall, P ≥ 0.56 for both). Average RNFLT, minimum RNFLT, average BMO-MRW, minimum BMO-MRW, cpVD, and cpFlow were all significantly lower (all P < 0.001) in the affected hemisphere in patients with POAG than in controls. In patients with POAG, the average mean deviation was -4.33 ± 3.25 dB; the PaTD of the affected hemifield averaged -4.55 ± 5.26 dB and correlated significantly with both OCTA and structural OCT parameters (r ≥ 0.43, P ≤ 0.004 for all). The model containing RNFLT, BMO-MRW, and OCTA parameters was superior in predicting affected PaTD (r2 = 0.47, BIC = 290.7), with higher r2 and lower BIC compared with all 3 other models. CONCLUSIONS A combined model of OCTA and structural OCT parameters can predict the severity of paracentral VF loss of the affected hemifield, supporting clinical utility of OCTA in patients with POAG with paracentral VF loss. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found after the references.
Collapse
Affiliation(s)
- Christine Xu
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Chhavi Saini
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Mengyu Wang
- Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Julia Devlin
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Haobing Wang
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Scott H Greenstein
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Stacey C Brauner
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Lucy Q Shen
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts.
| |
Collapse
|
7
|
Kamalipour A, Moghimi S, Khosravi P, Mohammadzadeh V, Nishida T, Micheletti E, Wu JH, Mahmoudinezhad G, Li EHF, Christopher M, Zangwill L, Javidi T, Weinreb RN. Combining Optical Coherence Tomography and Optical Coherence Tomography Angiography Longitudinal Data for the Detection of Visual Field Progression in Glaucoma. Am J Ophthalmol 2023; 246:141-154. [PMID: 36328200 PMCID: PMC11789620 DOI: 10.1016/j.ajo.2022.10.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 10/14/2022] [Accepted: 10/15/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE To use longitudinal optical coherence tomography (OCT) and OCT angiography (OCTA) data to detect glaucomatous visual field (VF) progression with a supervised machine learning approach. DESIGN Prospective cohort study. METHODS One hundred ten eyes of patients with suspected glaucoma (33.6%) and patients with glaucoma (66.4%) with a minimum of 5 24-2 VF tests and 3 optic nerve head and macula images over an average follow-up duration of 4.1 years were included. VF progression was defined using a composite measure including either a "likely progression event" on Guided Progression Analysis, a statistically significant negative slope of VF mean deviation or VF index, or a positive pointwise linear regression event. Feature-based gradient boosting classifiers were developed using different subsets of baseline and longitudinal OCT and OCTA summary parameters. The area under the receiver operating characteristic curve (AUROC) was used to compare the classification performance of different models. RESULTS VF progression was detected in 28 eyes (25.5%). The model with combined baseline and longitudinal OCT and OCTA parameters at the global and hemifield levels had the best classification accuracy to detect VF progression (AUROC = 0.89). Models including combined OCT and OCTA parameters had higher classification accuracy compared with those with individual subsets of OCT or OCTA features alone. Including hemifield measurements significantly improved the models' classification accuracy compared with using global measurements alone. Including longitudinal rates of change of OCT and OCTA parameters (AUROCs = 0.80-0.89) considerably increased the classification accuracy of the models with baseline measurements alone (AUROCs = 0.60-0.63). CONCLUSIONS Longitudinal OCTA measurements complement OCT-derived structural metrics for the evaluation of functional VF loss in patients with glaucoma.
Collapse
Affiliation(s)
- Alireza Kamalipour
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Sasan Moghimi
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Pooya Khosravi
- School of Medicine (P.K.), University of California, Irvine, Irvine, California, USA
| | - Vahid Mohammadzadeh
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Takashi Nishida
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Eleonora Micheletti
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Jo-Hsuan Wu
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Golnoush Mahmoudinezhad
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Elizabeth H F Li
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Mark Christopher
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Linda Zangwill
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology
| | - Tara Javidi
- Department of Electrical and Computer Engineering (T.J.), University of California San Diego, La Jolla
| | - Robert N Weinreb
- From the Hamilton Glaucoma (A.K., S.M., V.M., T.N., E.M., J-H.W., G.M., E.H.F.L., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology.
| |
Collapse
|
8
|
Hou W, Feng J, Chen J, Li X, Yang G, Sun X. Analysis of the Optic Nerve Head Microcirculation Using Optical Coherence Tomography Angiography and the Upstream Macrocirculation Using Color Doppler Imaging in Low-Tension and High-Tension Glaucoma Patients. Ophthalmic Res 2022; 66:579-589. [PMID: 36473452 DOI: 10.1159/000528521] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 11/25/2022] [Indexed: 12/12/2022]
Abstract
INTRODUCTION The aim of the study was to analyze the optic nerve head (ONH) microcirculation using optical coherence tomography angiography (OCT-A) and the upstream macrocirculation using color Doppler imaging (CDI) in low-tension and high-tension glaucoma (LTG and HTG, respectively). METHODS This cross-sectional study included 67 eyes of 67 HTG patients, 55 eyes of 55 LTG patients, and 42 eyes of 42 healthy controls. We recorded the complete ophthalmological examination, visual fields, retinal nerve fiber layer (RNFL) thickness, ONH vessel density (VD) measured using OCT-A, peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI) measured using CDI. SPSS software was used for data analysis. Data are presented as mean ± standard deviation or median (interquartile range) and compared using t test or Mann-Whitney U test, as appropriate. Pearson χ2 test or Fisher's exact test was used for comparisons, as appropriate. Pearson correlation analysis was used to evaluate the correlations between variables. p < 0.05 was considered statistically significant. RESULTS The ONH VD and RNFL thickness were considerably lower in glaucomatous eyes than in healthy eyes (both p < 0.001). Compared with the HTG group, the LTG group had lower VD in the peripapillary region (p = 0.027). Compared with the healthy group, the HTG group had lower PSV (p = 0.029 and = 0.023, respectively), lower EDV (p = 0.023 and <0.001, respectively), and higher RI (p = 0.019 and = 0.006, respectively) of the internal carotid artery (ICA) and central retinal artery (CRA). The LTG group had lower PSV (p = 0.015 and <0.001, respectively) and EDV (p = 0.047 and = 0.001, respectively) of the ophthalmic artery (OA) and CRA. The LTG group had lower PSV of CRA than the HTG group (p = 0.034). In glaucomatous eyes, peripapillary VD had a significant association with the mean defect (p < 0.001) and RNFL thickness (p < 0.001), but not with the other CDI indices (all p > 0.05). CONCLUSION The ONH microcirculation and upstream macrocirculation of the large arteries exhibited differences in the blood flow characteristics between the LTG and HTG groups. These differences may improve our understanding of glaucoma. There was no correlation between the characteristics of the ONH microcirculation and the upstream macrocirculation of large vessels in the LTG and HTG groups.
Collapse
Affiliation(s)
- Wenbo Hou
- Department II of Ophthalmology, The Eye Hospital, China Academy Of Chinese Medical Sciences, Beijing, China,
| | - Jun Feng
- Department II of Ophthalmology, The Eye Hospital, China Academy Of Chinese Medical Sciences, Beijing, China
| | - Jie Chen
- Department II of Ophthalmology, The Eye Hospital, China Academy Of Chinese Medical Sciences, Beijing, China
| | - Xin Li
- Department II of Ophthalmology, The Eye Hospital, China Academy Of Chinese Medical Sciences, Beijing, China
| | - Guiping Yang
- Department II of Ophthalmology, The Eye Hospital, China Academy Of Chinese Medical Sciences, Beijing, China
| | - Xuguang Sun
- Department of Ocular Microbiology, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Dongjiaomin Lane, Beijing, China
| |
Collapse
|
9
|
Kamalipour A, Moghimi S, Inpirom VR, Mahmoudinezhad G, Weinreb RN. Multipressure Dial Goggle Effects on Circumpapillary Structure and Microvasculature in Glaucoma Patients. Ophthalmol Glaucoma 2022; 5:572-580. [PMID: 35605936 PMCID: PMC10566504 DOI: 10.1016/j.ogla.2022.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 04/25/2022] [Accepted: 05/16/2022] [Indexed: 11/19/2022]
Abstract
PURPOSE To evaluate the effects of pressure changes induced by a multipressure dial (MPD) on circumpapillary retinal nerve fiber layer (RNFL) and capillary density (CD) measurements in patients with glaucoma using OCT angiography (OCTA). DESIGN Prospective interventional study. PARTICIPANTS Twenty-four patients with primary open-angle glaucoma. METHODS One eye of each patient underwent negative pressure application with the MPD. The MPD alters intraocular pressure (IOP) relative to atmospheric pressure by generating a negative pressure vacuum within a goggle chamber that is placed over the eye. Each participant underwent serial high density OCTA imaging (AngioVue) of the optic nerve head at different negative pressure increments of -5 mmHg, starting from 0 mmHg, ending at -20 mmHg, and then returning to baseline. Images were acquired after 2 minutes of sustained negative pressure at each target pressure to allow for stabilization of the retinal structures and microvasculature. The RNFL thickness and CD measurements were automatically calculated using the native AngioVue software, and then exported for analysis. MAIN OUTCOME MEASURES The influence of different levels of negative pressure on circumpapillary RNFL thickness and CD measurements, assessed by a linear mixed-effects model with repeated measures. RESULTS The mean (± SD) age was 71.0 years (± 7.8 years), the baseline IOP was 17.5 mmHg (± 3.6 mmHg), and there was a mean 24-2 mean deviation of -2.80 dB (± 2.55 dB). Serial circumpapillary CD measurements showed a statistically significant dose-dependent increase from baseline, without negative pressure application, to the maximum negative pressure application of -20 mmHg (difference, 2.27%; P = 0.010). Capillary density measurements then decreased symmetrically when lowering the negative pressure to baseline. Circumpapillary CD measurements at target negative pressures of -10 mmHg, -15 mmHg, and -20 mmHg were significantly higher than the baseline measurements (all P values < 0.05). Circumpapillary RNFL thickness remained the same throughout different levels of negative pressure. CONCLUSIONS Circumpapillary CD measurements showed a dose-dependent increase with the induction of negative pressure, while RNFL thickness measurements remained unchanged.
Collapse
Affiliation(s)
- Alireza Kamalipour
- Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, CA
| | - Sasan Moghimi
- Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, CA
| | - Veronica R Inpirom
- Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, CA
| | - Golnoush Mahmoudinezhad
- Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, CA
| | - Robert N Weinreb
- Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, CA.
| |
Collapse
|
10
|
Retinal Oxygen Extraction in Patients with Primary Open-Angle Glaucoma. Int J Mol Sci 2022; 23:ijms231710152. [PMID: 36077550 PMCID: PMC9456494 DOI: 10.3390/ijms231710152] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 08/26/2022] [Accepted: 08/29/2022] [Indexed: 12/02/2022] Open
Abstract
Objective: To compare total retinal oxygen extraction between patients with primary open-angle glaucoma (POAG) and healthy control subjects. Design: A prospective, single-center, cross-sectional, case−control study performed at the Medical University of Vienna. Subjects: Forty patients with POAG and 40 age- and sex-matched control subjects. Methods: Total retinal blood flow was measured using Doppler optical coherence tomography (OCT). Retinal arterial and venous oxygen saturation was measured using reflectance spectroscopy. From these parameters, oxygen content in the retinal arterial and venous circulation as well as total retinal oxygen extraction were calculated. Results: Total retinal blood flow was lower in POAG (25.2 ± 6.7 µL/min) as compared to healthy control subjects (35.6 ± 8.3 µL/min, p < 0.001). Retinal arterial oxygen content was not different between the two groups (0.18 ± 0.01 mL(O2)/mL in both groups, p < 0.761), but retinal venous oxygen content was higher in POAG (0.15 ± 0.01 mL(O2)/mL) than in healthy controls (0.14 ± 0.01 mL(O2)/mL p < 0.001). Accordingly, retinal oxygen extraction was reduced in POAG (0.8 ± 0.3 µL(O2)/min as compared to healthy controls: 1.4 ± 0.4 µL(O2)/min, p < 0.001). There was a significant association between total retinal blood flow and total retinal oxygen extraction with measures of structural and functional damage (p < 0.001 each). Conclusions: This study indicates that POAG is associated with a reduction in total retinal oxygen extraction linked to structural and functional damage of the disease. Since the technology is non-invasive, it allows for longitudinal studies investigating to which degree low retinal oxygen extraction is linked to the progression of the disease.
Collapse
|
11
|
Wong D, Chua J, Bujor I, Chong RS, Nongpiur ME, Vithana EN, Husain R, Aung T, Popa‐Cherecheanu A, Schmetterer L. Comparison of machine learning approaches for structure-function modeling in glaucoma. Ann N Y Acad Sci 2022; 1515:237-248. [PMID: 35729796 PMCID: PMC10946805 DOI: 10.1111/nyas.14844] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
To evaluate machine learning (ML) approaches for structure-function modeling to estimate visual field (VF) loss in glaucoma, models from different ML approaches were trained on optical coherence tomography thickness measurements to estimate global VF mean deviation (VF MD) and focal VF loss from 24-2 standard automated perimetry. The models were compared using mean absolute errors (MAEs). Baseline MAEs were obtained from the VF values and their means. Data of 832 eyes from 569 participants were included, with 537 Asian eyes for training, and 148 Asian and 111 Caucasian eyes set aside as the respective test sets. All ML models performed significantly better than baseline. Gradient-boosted trees (XGB) achieved the lowest MAE of 3.01 (95% CI: 2.57, 3.48) dB and 3.04 (95% CI: 2.59, 3.99) dB for VF MD estimation in the Asian and Caucasian test sets, although difference between models was not significant. In focal VF estimation, XGB achieved median MAEs of 4.44 [IQR 3.45-5.17] dB and 3.87 [IQR 3.64-4.22] dB across the 24-2 VF for the Asian and Caucasian test sets and was comparable to VF estimates from support vector regression (SVR) models. VF estimates from both XGB and SVR were significantly better than the other models. These results show that XGB and SVR could potentially be used for both global and focal structure-function modeling in glaucoma.
Collapse
Affiliation(s)
- Damon Wong
- SERI‐NTU Advanced Ocular Engineering (STANCE)Singapore
- School of Chemical and Biomedical EngineeringNanyang Technological UniversitySingapore
- Singapore Eye Research InstituteSingapore National Eye CentreSingapore
- Institute of Molecular and Clinical OphthalmologyBaselSwitzerland
| | - Jacqueline Chua
- SERI‐NTU Advanced Ocular Engineering (STANCE)Singapore
- Singapore Eye Research InstituteSingapore National Eye CentreSingapore
| | - Inna Bujor
- Carol Davila University of Medicine and PharmacyBucharestRomania
| | - Rachel S. Chong
- Singapore Eye Research InstituteSingapore National Eye CentreSingapore
| | | | - Eranga N. Vithana
- Singapore Eye Research InstituteSingapore National Eye CentreSingapore
| | - Rahat Husain
- Singapore Eye Research InstituteSingapore National Eye CentreSingapore
| | - Tin Aung
- Singapore Eye Research InstituteSingapore National Eye CentreSingapore
- Yong Loo Lin School of MedicineNational University of SingaporeSingapore
| | - Alina Popa‐Cherecheanu
- Carol Davila University of Medicine and PharmacyBucharestRomania
- Department of OphthalmologyEmergency University HospitalBucharestRomania
| | - Leopold Schmetterer
- SERI‐NTU Advanced Ocular Engineering (STANCE)Singapore
- School of Chemical and Biomedical EngineeringNanyang Technological UniversitySingapore
- Singapore Eye Research InstituteSingapore National Eye CentreSingapore
- Institute of Molecular and Clinical OphthalmologyBaselSwitzerland
- Department of Clinical PharmacologyMedical University of ViennaViennaAustria
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| |
Collapse
|
12
|
Microvascular changes in the macular and parafoveal areas of multiple sclerosis patients without optic neuritis. Sci Rep 2022; 12:13366. [PMID: 35922463 PMCID: PMC9349324 DOI: 10.1038/s41598-022-17344-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Accepted: 07/25/2022] [Indexed: 02/08/2023] Open
Abstract
Retinal imaging has been proposed as a biomarker for neurological diseases such as multiple sclerosis (MS). Recently, a technique for non-invasive assessment of the retinal microvasculature called optical coherence tomography angiography (OCTA) was introduced. We investigated retinal microvasculature alterations in participants with relapsing–remitting MS (RRMS) without history of optic neuritis (ON) and compared them to a healthy control group. The study was performed in a prospective, case–control design, including 58 participants (n = 100 eyes) with RRMS without ON and 78 age- and sex-matched control participants (n = 136 eyes). OCTA images of the superficial capillary plexus (SCP), deep capillary plexus (DCP) and choriocapillaris (CC) were obtained using a commercial OCTA system (Zeiss Cirrus HD-5000 Spectral-Domain OCT with AngioPlex OCTA, Carl Zeiss Meditec, Dublin, CA). The outcome variables were perfusion density (PD) and foveal avascular zone (FAZ) features (area and circularity) in both the SCP and DCP, and flow deficit in the CC. MS group had on average higher intraocular pressure (IOP) than controls (P < 0.001). After adjusting for confounders, MS participants showed significantly increased PD in SCP (P = 0.003) and decreased PD in DCP (P < 0.001) as compared to controls. A significant difference was still noted when large vessels (LV) in the SCP were removed from the PD calculation (P = 0.004). Deep FAZ was significantly larger (P = 0.005) and less circular (P < 0.001) in the eyes of MS participants compared to the control ones. Neither LV, PD or FAZ features in the SCP, nor flow deficits in the CC showed any statistically significant differences between the MS group and control group (P > 0.186). Our study indicates that there are microvascular changes in the macular parafoveal retina of RRMS patients without ON, showing increased PD in SCP and decreased PD in DCP. Further studies with a larger cohort of MS patients and MRI correlations are necessary to validate retinal microvascular changes as imaging biomarkers for diagnosis and screening of MS.
Collapse
|
13
|
Young SL, Jain N, Tatham AJ. The application of advanced imaging techniques in glaucoma. EXPERT REVIEW OF OPHTHALMOLOGY 2022. [DOI: 10.1080/17469899.2022.2101449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- Su Ling Young
- Princess Alexandra Eye Pavilion, Edinburgh, UK
- Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK
| | - Nikhil Jain
- Addenbrooke’s Hospital, Cambridge University Hospitals NHS trust, Cambridge, UK
| | - Andrew J Tatham
- Princess Alexandra Eye Pavilion, Edinburgh, UK
- Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK
| |
Collapse
|
14
|
A Global and Sector-Based Comparison of OCT Angiography and Visual Field Defects in Glaucoma. J Ophthalmol 2022; 2022:6182592. [PMID: 35607610 PMCID: PMC9124140 DOI: 10.1155/2022/6182592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 04/08/2022] [Accepted: 04/25/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose. To evaluate the correlation of optical coherence tomography angiography (OCTA) and spectral-domain optical coherence tomography (SD-OCT) with visual field for global and sector-based indices among glaucoma and glaucoma-suspected eyes. Patients and Methods. This is a retrospective study, and in total, 48 glaucoma eyes and 31 glaucoma suspect eyes were included. The correlation between visual field parameters and radial peripapillary capillary (RPC) vessel density via OCTA was compared to the correlation with retinal nerve fiber layer (RNFL) thickness via SD-OCT. The RPC vessel density and RNFL thickness were divided into eight sectors, which included the temporal upper, temporal lower, superotemporal, inferotemporal, superonasal, inferonasal, nasal upper, and nasal lower sectors. Pearson correlations with 95% confidence intervals were calculated with resampling, and correlations were compared with a Fisher Z transformation. Results. Both RPC vessel density (R = 0.63, 95% CI [0.24, 0.86]) and RNFL thickness (R = 0.49, 95% CI [0.23, 0.69]) were correlated with the mean deviation when comparing global indices of glaucoma patients. In glaucoma suspects, the correlations between the mean deviation and RPC vessel density (R = 0.21, 95% CI [−0.05, 0.49]) and RNFL thickness (R = 0.01, 95% CI [−0.35, 0.39]) were not significant. Glaucoma eyes had the highest correlation between the mean sensitivity and RPC vessel density and RNFL thickness for the superotemporal, superonasal, temporal upper, and inferotemporal sectors. Conclusion. Across a diverse population and heterogeneous glaucoma types, RPC vessel density measurements correlate with global and sector-wise visual field indices similar to RNFL thickness.
Collapse
|
15
|
KAMALIPOUR ALIREZA, MOGHIMI SASAN, HOU HUIYUAN, PROUDFOOT JAMESA, NISHIDA TAKASHI, ZANGWILL LINDAM, WEINREB ROBERTN. Multilayer Macula Vessel Density and Visual Field Progression in Glaucoma. Am J Ophthalmol 2022; 237:193-203. [PMID: 34801510 DOI: 10.1016/j.ajo.2021.11.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 11/05/2021] [Accepted: 11/11/2021] [Indexed: 11/01/2022]
Abstract
PURPOSE To evaluate the association of macular superficial vessel density (SVD) and projection-resolved deep vessel density (DVD) with past visual field (VF) progression in patients with primary open-angle glaucoma. DESIGN Retrospective cohort. METHODS In this longitudinal study, 208 eyes of 147 patients with glaucoma from the Diagnostics Innovations in Glaucoma Study were included. Eligible participants were required to have at least five 24-2 VF tests over a minimum follow-up period of 3 years before macular optical coherence tomography angiography imaging. VF progression was defined based on both event-based pointwise linear regression and trend-based methods. The association of macular SVD and DVD with the probability and rate of past VF progression was evaluated using a linear mixed effects model. RESULTS Fifty-two (25%) eyes had VF progression based on the pointwise linear regression based criterion at the end of a mean ± standard deviation follow-up duration of 6.9 ± 1.2 years. In the event-based multivariable analysis, a lower baseline SVD was associated with a higher likelihood of past VF progression (odds ratio per 1% lower. 1.28; 95% confidence interval, 1.02-1.59). Similarly, in the trend-based multivariable analysis, lower macular SVD was associated with a faster past rate of mean deviation decline (coefficient = -0.03 dB/year; 95% confidence interval, -0.04 to -0.01). Event-based and trend-based analyses found no significant associations for macular DVD with the likelihood/rate of past VF progression (P > .05). CONCLUSIONS Lower macular SVD, and not DVD, was associated with a higher probability of past VF progression. Macular optical coherence tomography angiography imaging shows promise for identifying eyes at risk of VF progression in patients with glaucoma.
Collapse
|
16
|
Kallab M, Hommer N, Schlatter A, Chua J, Tan B, Schmidl D, Hirn C, Findl O, Schmetterer L, Garhöfer G, Wong D. Combining vascular and nerve fiber layer thickness measurements to model glaucomatous focal visual field loss. Ann N Y Acad Sci 2022; 1511:133-141. [PMID: 35029314 PMCID: PMC9305098 DOI: 10.1111/nyas.14732] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 11/01/2021] [Accepted: 11/12/2021] [Indexed: 11/29/2022]
Abstract
We compare the focal structure-function correlation of structural measurements of peripapillary retinal nerve fiber layer thickness (RNFL-T) using optical coherence tomography (OCT), capillary density (CD) measurements using OCT-angiography (OCT-A), or a combination of both, with visual field deviation (VFD) in early to advanced glaucoma. Primary open angle glaucoma patients (n = 46, mean ± SD age: 67 ± 10 years; VF mean deviation: -10.41 ± 6.76 dB) were included in this cross-sectional study. We performed 30-2 standard automated perimetry OCT (3.5-mm diameter ring scan) and 15°×15° OCT-A (superficial vascular complex slab). Based on a nerve fiber trajectory model, each VF test spot was assigned to an OCT-A wedge and an OCT ring-sector. Two univariate linear models (Mv and Mt ) using either CD-based vascular (Mv ) or RNFL-T-based thickness information (Mt ) and one multivariate model using both (Mv:t ) were compared in their associations with measured focal VFD, which were higher for the multivariate model Mv:t (mean ± SD correlation coefficient: 0.710 ± 0.086) than for either nested model (0.627 ± 0.078 for Mv and 0.578 ± 0.095 for Mt ). Using a focal visual field approach, the combination of RNFL-T and CD showed better structure-function correlations than thickness or vascular information only.
Collapse
Affiliation(s)
- Martin Kallab
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Nikolaus Hommer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Andreas Schlatter
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria.,Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital, Vienna, Austria
| | - Jacqueline Chua
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.,Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
| | - Bingyao Tan
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.,SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore.,School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, Singapore
| | - Doreen Schmidl
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Cornelia Hirn
- Department of Ophthalmology, Hanusch Hospital, Vienna, Austria
| | - Oliver Findl
- Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital, Vienna, Austria.,Department of Ophthalmology, Hanusch Hospital, Vienna, Austria
| | - Leopold Schmetterer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria.,Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.,Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore.,SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore.,School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, Singapore.,Institute of Molecular and Clinical Ophthalmology Basel, Basel, Switzerland.,Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Gerhard Garhöfer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Damon Wong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.,SERI-NTU Advanced Ocular Engineering (STANCE), Singapore, Singapore.,School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, Singapore.,Institute of Molecular and Clinical Ophthalmology Basel, Basel, Switzerland
| |
Collapse
|
17
|
Wong D, Chua J, Tan B, Yao X, Chong R, Sng CCA, Husain R, Aung T, Garway-Heath D, Schmetterer L. Combining OCT and OCTA for Focal Structure-Function Modeling in Early Primary Open-Angle Glaucoma. Invest Ophthalmol Vis Sci 2021; 62:8. [PMID: 34878500 PMCID: PMC8662568 DOI: 10.1167/iovs.62.15.8] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To investigate modeling of the focal visual field (VF) loss by combining structural measurements and vascular measurements in eyes with early primary open-angle glaucoma (POAG). Methods In this cross-sectional study, subjects with early glaucoma (VF mean deviation, ≥−6 dB) underwent optical coherence tomography (OCT) imaging, optical coherence tomography angiography (OCTA) imaging, and Humphrey 24-2 VF tests. Capillary perfusion densities (CPDs) were calculated after the removal of large vessels in the OCTA images. Focal associations between VF losses at the individual VF test locations, circumpapillary retinal nerve fiber layer (RNFL) thickness measurements from OCT, and CPDs were determined using nerve fiber trajectory tracings. Linear mixed models were used to model focal VF losses at each VF test location. Results Ninety-seven eyes with early POAG (VF mean deviation, −2.47 ± 1.64 dB) of 71 subjects were included. Focal VF modeling using a combined RNFL–CPD approach resulted in a median adjusted R2 value of 0.30 (interquartile range [IQR], 0.13–0.55), whereas the RNFL-only and CPD-only approaches resulted in median values of 0.22 (IQR, 0.10–0.51) and 0.26 (IQR, 0.10–0.52), respectively. Seventeen VF locations with the combined approach had an adjusted R2 value greater than 0.50. Likelihood testing at each VF test location showed that the combined approach performed significantly better at the superior nasal VF regions of the eyes compared with the univariate approaches. Conclusions Modeling of focal VF losses showed improvements when structural thickness and vascular parameters were included in tandem. Evaluation of VF defects in early glaucoma may benefit from considering both RNFL and OCTA characteristics.
Collapse
Affiliation(s)
- Damon Wong
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore.,School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore.,Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Jacqueline Chua
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Bingyao Tan
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore.,School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore.,Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Xinwen Yao
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore.,School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore.,Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Rachel Chong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Chelvin C A Sng
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Department of Ophthalmology, National University Hospital, Singapore
| | - Rahat Husain
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Tin Aung
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Academic Clinical Program, Duke-NUS Medical School, Singapore.,Department of Ophthalmology, National University Hospital, Singapore.,Department of Ophthalmology, National University Hospital, Singapore
| | - David Garway-Heath
- NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.,Institute of Ophthalmology, University College, London, United Kingdom
| | - Leopold Schmetterer
- SERI-NTU Advanced Ocular Engineering (STANCE), Singapore.,School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore.,Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.,Department of Ophthalmology, National University Hospital, Singapore.,Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria.,Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| |
Collapse
|