1
|
Comparison of risk factors for OBL in FS-LASIK and SMILE correction for myopia and myopia astigmatism. Graefes Arch Clin Exp Ophthalmol 2024; 262:1925-1931. [PMID: 38091059 DOI: 10.1007/s00417-023-06336-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/26/2023] [Accepted: 11/30/2023] [Indexed: 05/22/2024] Open
Abstract
BACKGROUND To find out the incidence and risk factors of opaque bubble layer (OBL) in eyes with myopia and myopic astigmatism following femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE). METHODS A total of 1076 eyes from 569 patients who had FS-LASIK or SMILE were included in the retrospective research. For each kind of surgery, eyes were separated into two groups: "OBL" groups and "no OBL" groups. In the FS-LASIK group, eyes that developed OBL were split into "hard OBL" and "soft OBL" groups. The incidence and size of OBL were analyzed after watching the surgical procedure videotaped during the operation and taking screenshots. Surgical parameters, including sphere, cylinder, keratometry, corneal thickness, flap thickness, cap thickness, lenticule thickness, and visual acuity, were compared. RESULTS In the FS-LASIK surgery, the incidence of OBL was 63.2% (347 eyes). A thicker central corneal thickness (CCT) was the only independent risk factor affecting the OBL area (β = 0.126, P = 0.019). One hundred and thirty of these eyes had hard OBL, and the flap thickness of these eyes was thinner than that of those with soft OBL (P = 0.027). In the SMILE group, 26.6% (140 eyes) developed OBL. A higher flat keratometry (K) and a thicker residual stromal thickness (RST) were risk factors affecting the OBL area (β = 0.195, P = 0.024; β = 0.281, P = 0.001). CONCLUSION The incidence of OBL differs between the FS-LASIK surgery and the SMILE surgery. There are differences in the factors influencing OBL between the two surgeries.
Collapse
|
2
|
Myopic Regression after FS-LASIK and SMILE. Cornea 2024:00003226-990000000-00563. [PMID: 38780430 DOI: 10.1097/ico.0000000000003573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Accepted: 04/13/2024] [Indexed: 05/25/2024]
Abstract
PURPOSE To compare the degree of myopic regression after myopia correction with either femtosecond laser-assisted in situ keratomileusis (FS-LASIK) or small-incision lenticule extraction (SMILE) over 18 months. METHODS Patients undergoing FS-LASIK or SMILE surgery for myopia correction were retrospectively recruited. The propensity scores were used to match patients by age and preoperative manifest spherical equivalent (SEQ) from these 2 groups. Myopic regression was analyzed using the Cox proportional hazard model. RESULTS A total of 416 eyes of 416 patients undergoing FS-LASIK and 416 eyes of 416 patients undergoing SMILE were matched. Using 1-month SEQ as baseline, the SEQ regression values after FS-LASIK were 0D, -0.17 ± 0.69D, -0.24 ± 0.65D, -0.31 ± 0.65D, -0.32 ± 0.63D, and -0.33 ± 0.62D and the SEQ regression values after SMILE were 0D, -0.07 ± 0.75D, -0.18 ± 0.77D, -0.23 ± 0.82 D, -0.21 ± 0.77D, and -0.24 ± 0.68D at 1, 3, 6, 9, 12, and 18 months, respectively. The Cox proportional hazard model showed that preoperative manifest SEQ (P = 0.021) and designed optical zone (P = 0.048) are significant predictors. The selected surgical procedure had no significant effect on predicting myopic regression (P = 0.470). The cumulative survival rates of myopic regression were 54.74% and 42.10% in the FS-LASIK group and 58.66% and 43.83% in the SMILE group, at 12 and 18 months, respectively (log-rank test, P = 0.11). CONCLUSIONS After matching based on age and preoperative manifest SEQ, we found that higher myopia and a smaller optical zone contribute significantly to the development of myopic regression after undergoing FS-LASIK or SMILE surgery at 18 months. The selected surgical procedure, however, does not affect the likelihood of myopic regression.
Collapse
|
3
|
Investigation of the optimal cutting depth in small incision lenticule extraction based on a collagen fibril crimping constitutive model of the cornea. J Biomech 2024; 169:112145. [PMID: 38761745 DOI: 10.1016/j.jbiomech.2024.112145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 04/30/2024] [Accepted: 05/08/2024] [Indexed: 05/20/2024]
Abstract
To investigate the optimal cutting depth (Cap) in small incision lenticule extraction from the perspective of corneal biomechanics, a three-dimensional finite element model of the cornea was established using a stromal sub-regional material model to simulate small incision lenticule extraction. The displacement difference PΔ at the central point of the posterior corneal surface before and after lenticule extraction, as well as the von Mises stress at four points of different thicknesses in the center of the cornea, were analyzed using the finite element model considering the hyperelastic property and the difference in stiffness between the anterior and posterior of the cornea. The numerical curves of PΔ-Cap and von Mises Stress-Cap relations at different diopters show that the displacement difference PΔ has a smallest value at the same diopter. In this case, the von Mises stress at four points with different thicknesses in the center of the cornea was also minimal. Which means that the optimal cutting depth exsisting in the cornea. Moreover, PΔ-Cap curves for different depth of stromal stiffness boundaries show that the optimal cap thickness would change with the depth of the stromal stiffness boundary. These results are of guiding significance for accurately formulating small incision lenticule extraction surgery plans and contribute to the advancement of research on the biomechanical properties of the cornea.
Collapse
|
4
|
Differences in ocular high order aberrations before and after small incision lenticule extraction for correction of myopia: a systematic review and meta-analysis. Front Med (Lausanne) 2024; 11:1274101. [PMID: 38601117 PMCID: PMC11004322 DOI: 10.3389/fmed.2024.1274101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 03/13/2024] [Indexed: 04/12/2024] Open
Abstract
Objective To examine the causes and factors that lead to high order aberration (HOA) during the treatment of myopia using small incision lenticule extraction (SMILE), as well as the differences between SMILE and other corneal refractive surgeries through a systematic review and meta-analysis. Methods A systematic search was conducted from January 2015 to February 2023 in Pubmed, Embase, Web of Science, and Google Scholar databases to gather relevant studies on SMILE and HOA. Studies meeting specific criteria were chosen, and clinical data was retrieved for analysis. Results This meta-analysis resulted in the inclusion of 19 studies involving 1,503 eyes. Pooled results showed significant induction of total HOA (tHOA, d = -0.21, p < 0.001), spherical aberration (SA, d = -0.11, p < 0.001) and coma aberration (CA, d = -0.18, p < 0.001) after SMILE compared to pre-SMILE, while no significant change in trefoil aberration (TA) was observed (d = -0.00, p = 0.91). There was a significantly lower induction of tHOA after SMILE compared to femtosecond laser-assisted in situ keratomileusis (FS-LASIK, d = 0.04, p < 0.001), and no significant difference was observed compared to wavefront aberration-guided (WFG) refractive surgery (d = 0.00, p = 0.75). There was also a significant association between different levels of myopia and astigmatism, duration of follow-up, lenticule thickness, and preoperative central corneal thickness (CCT) on the induction of tHOA after SMILE (p < 0.05), while the higher preoperative myopia group (sphere > -5D), lower preoperative astigmatism group (cylinder ≤ -1D), larger lenticule thickness group (lenticule thickness > 100 μm), shorter follow-up group (follow-up 1 month postoperatively) and the thicker CCT group (CCT > 550 μm) brought a significant induction of tHOA compared to the opposite comparison group (p < 0.001). Conclusion While SMILE can induce HOA significantly, it induces less HOA than FS-LASIK. Postoperative HOA following SMILE can be affected by factors such as myopia, astigmatism, lenticule thickness, CCT, and duration of follow-up. Future research should continue to explore techniques to decrease the induction of HOA by using this methodology. Systematic review registration https://www.crd.york.ac.uk/prospero/.
Collapse
|
5
|
Comparative Analysis of Corneal Higher-Order Aberrations after Laser-Assisted In Situ Keratomileusis, Photorefractive Keratectomy, and Small Incision Lenticule Extraction with Correlations to Change in Myopic Q-Value and Spherical Equivalent with and without Astigmatism. J Clin Med 2024; 13:1906. [PMID: 38610671 PMCID: PMC11012266 DOI: 10.3390/jcm13071906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 03/15/2024] [Accepted: 03/19/2024] [Indexed: 04/14/2024] Open
Abstract
Background: This retrospective chart review compared the higher-order aberrations (HOAs) among photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis (LASIK), and small incision lenticule extraction (SMILE) alongside changes in spherical equivalent (SEQ) and corneal shape (Q-value). Methods: Analyzing 371 myopic eyes, including 154 LASIK, 173 PRK, and 44 SMILE cases, Pentacam imaging was utilized pre-operatively and at one-year post-operative visits. Results: All procedures resulted in 100% of patients achieving an uncorrected distance visual acuity (UDVA) of 20/40 or better, with 87% of LASIK and PRK, and 91% of SMILE patients having 20/20 or better. Significant increases in HOAs were observed across all procedures (p < 0.05), correlating positively with SEQ and Q-value changes (LASIK (0.686, p < 0.05), followed by PRK (0.4503, p < 0.05), and SMILE (0.386, p < 0.05)). Vertical coma and spherical aberration (SA) were the primary factors for heightened aberration magnitude among the procedures (p < 0.05), with the largest contribution in SMILE, which is likely attributed to the centration at the corneal apex. Notably, PRK showed insignificant changes in vertical coma (-0.197 µm ± 0.0168 to -0.192 µm ± 0.0198, p = 0.78), with an increase in oblique trefoil (p < 0.05). Conclusions: These findings underscore differences in HOAs among PRK, LASIK, and SMILE, helping to guide clinicians.
Collapse
|
6
|
Comparison of 110- and 145-µm Small-Incision Lenticule Extraction Cap Thickness: A Randomized Contralateral Eye Study. Cornea 2024; 43:154-158. [PMID: 37186807 DOI: 10.1097/ico.0000000000003294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 03/13/2023] [Indexed: 05/17/2023]
Abstract
PURPOSE To investigate the visual, refractive, and biomechanical outcomes of small incision lenticule extraction (SMILE) with two different cap thicknesses. METHODS Thirty-four patients were included in this prospective, randomized, contralateral eye study. Subjects were randomized to receive SMILE surgery with a 110-m cap thickness in one eye and 145-µm cap thickness in the fellow eye. Uncorrected and corrected distance visual acuity, contrast sensitivity (CS), total higherorder aberrations (THOAs) and corneal biomechanical properties were compared 3 months after surgery. RESULTS Postoperative refractive and visual outcomes, CS and THOAs were similar between the two groups ( P > 0.05 for all parameters). At 3 months postoperatively, there was a significant difference in Corvis ST Biomechanical Index (CBI); stiffness parameter at first applanation (SP A1), and Integrated Radius between the two groups (all P < 0.05). CONCLUSIONS Eyes with thicker SMILE corneal caps showed no advantage regarding visual acuity, CS and THOAs over eyes with thinner caps. However, higher cap thickness may result in better corneal biomechanical properties postoperatively.
Collapse
|
7
|
Corneal Biomechanics After SMILE, Femtosecond-Assisted LASIK, and Photorefractive Keratectomy: A Matched Comparison Study. Transl Vis Sci Technol 2023; 12:12. [PMID: 36928130 PMCID: PMC10029763 DOI: 10.1167/tvst.12.3.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023] Open
Abstract
Purpose To evaluate the change in corneal stiffness after small incision lenticule extraction (SMILE), femtosecond laser-assisted in situ keratomileusis (FS-LASIK), and photorefractive keratectomy (PRK). Methods Age, gender, spherical equivalent, and central corneal thickness (CCT)-matched cases undergoing SMILE with a 120-µ cap, FS-LASIK with a 110-µ flap, and PRK were enrolled. One-year change in the stress-strain index, stiffness parameter at first applanation, integrated inverse radius, deformation amplitude ratio at 2 mm, and deformation amplitude ratio at 1 mm were compared between the surgical groups by linear mixed-effect models. Results Within each surgical group, 120 eyes completed 1 year of follow-up. The residual stromal bed (RSB) thickness and (RSB/CCTpostop) were 348.1 ± 35.0 (0.74), 375.4 ± 31.0 (0.77) and 426.7 ± 2 µm (0.88) after SMILE, FS-LASIK, and PRK, respectively. The 1-year change in all biomechanical indices was significant, except the stress-strain index with PRK (P = 0.884). The change in all indices with SMILE were significantly greater than with FS-LASIK and with PRK (all P < 0.01), except the deformation amplitude ratio at 1 mm change between SMILE and FS-LASIK (P = 0.075). The changes in all indices with FS-LASIK were significantly greater than with PRK (all P < 0.05). Conclusions Although SMILE preserves the greatest amount of anterior cornea with a cap thickness of 120 µ, this also produces the smallest RSB and the greatest decrease in stiffness. Thus, the RSB is shown to be the predominant determinant of stiffness decreases, rather than the preserved anterior cornea. We recommend using a thinner cap to achieve a thicker RSB and a lesser decrease in the corneal stiffness in the SMILE procedure. Translational Relevance After refractive surgery, RSB is predominant determinant of stiffness decreases, rather than the preserved anterior cornea.
Collapse
|
8
|
Corneal biomechanical characteristics following small incision lenticule extraction for myopia and astigmatism with 3 different cap thicknesses. BMC Ophthalmol 2023; 23:42. [PMID: 36717828 PMCID: PMC9885585 DOI: 10.1186/s12886-023-02786-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 01/16/2023] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND The design of cap thickness for small incision lenticule extraction (SMILE) plays a role in post-laser vision correction (post-LVC) corneal biomechanics. This study aimed to compare the corneal biomechanical characteristics following SMILE with different cap thicknesses of 110 μm, 120 μm, and 130 μm for myopia and myopic astigmatism correction. METHODS Seventy-five patients (146 eyes) who underwent SMILE with designed cap thickness of 110 μm, 120 μm, and 130 μm were recruited at the Eye Center of Beijing Tongren Hospital between August 2020 and November 2021. Visual acuity, refraction, and corneal biomechanical parameters were measured preoperatively, 1 week and 1, 3, 6 months postoperatively. One-way analysis of variances (ANOVA) with Bonferroni correction or Kruskal-Wallis test was performed to compare the parameters among different groups. Repeated-measures analysis of variance with Bonferroni correction or Friedman test was applied for comparing the parameters within different follow-up times. RESULTS Uncorrected distance visual acuity of 110-μm group was better only at 1-week and 1-month postoperatively (P = 0.012, 0.037). There were no significant differences in spherical equivalent, nor in Corvis biomechanical index-laser vision correction (CBI-LVC). All the parameters reached stability at 3-month postoperatively. Integrated radius (IR) and deformation amplitude ratio 2 mm (DA ratio 2 mm) in 120-μm and 130-μm groups were higher than 110-μm group at 1-month postoperatively (P = 0.019, 0.002). So was Ambrósio relational thickness (ARTh) at 6-month postoperatively (P = 0.011). Stiffness parameter at applanation A1 (SP-A1), stress-strain index (SSI), biomechanically corrected intraocular pressure (bIOP) and central corneal thickness (CCT) were highest in 130-μm group, followed by 120-μm group, then 110-μm group at 3-month (P<0.001, P = 0.030, P = 0.027, P = 0.008) and 6-month (P<0.001, P = 0.002, P = 0.0023, P = 0.001) postoperatively. CONCLUSIONS The corneal stiffness following SMILE was greatest with 130-μm cap, followed by 120-μm cap, then 110-μm cap. 130-μm cap might have advantages in terms of corneal biomechanics and retreatment option. The SMILE-designed protocol should be customized in practice.
Collapse
|
9
|
Comparison of Changes in Corneal Thickness and Curvature After Myopia Correction Between SMILE and FS-LASIK. J Refract Surg 2023; 39:15-22. [PMID: 36630439 DOI: 10.3928/1081597x-20221130-03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE To comparatively investigate the changes in corneal thickness and curvature between small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). METHODS Data were collected preoperatively and postoperatively at 1 week, 1 month, and 3 months, including central corneal thickness (CCT), midperipheral corneal thickness (MPCT), peripheral corneal thickness (PCT), central keratometry (CK), midperipheral keratometry (MPK), and peripheral keratometry (PK), using a dual rotating Scheimpflug analyzer. RESULTS At 1 week postoperatively, changes in CCT, MPCT, PCT, and PK were significantly greater in the SMILE group than in the FS-LASIK group (P = .003 for CCT and < .001 for MPCT, PCT, and PK), but no significant inter-group differences were found between changes in CK and MPK (P = .883 and .513, respectively). CCT, MPCT, and PK values showed a similar increase in both groups, but significantly more increase in PCT and significantly less increase in CK and MPK was observed in the SMILE group from 1 week to 3 months after surgery. At 3 months postoperatively, CCT and MPCT were significantly thinner in the SMILE group than in the FSLASIK group (P = .018 and .022, respectively), and there was no significant difference in PCT, CK, MPK, and PK between the two groups. CONCLUSIONS SMILE caused significantly more corneal thinning at the center, midperiphery, and periphery, and more corneal flattening at the periphery, compared to FS-LASIK. A different pattern of corneal remodeling was observed between the two surgeries during the 3-month follow-up period. [J Refract Surg. 2023;39(1):15-22.].
Collapse
|
10
|
Clinical Evaluation of Corneal Biomechanics following Laser Refractive Surgery in Myopic Eyes: A Review of the Literature. J Clin Med 2022; 12:jcm12010243. [PMID: 36615041 PMCID: PMC9821300 DOI: 10.3390/jcm12010243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/18/2022] [Accepted: 12/23/2022] [Indexed: 12/31/2022] Open
Abstract
The role of corneal biomechanics in laser vision correction (LVC) is currently being raised in the assessment of postoperative corneal ectasia risk. The aim of the paper was to evaluate the changes in corneal biomechanics after LVC procedures based on a systematic review of current studies. The results of a search of the literature in the PubMed, Science Direct, Google Scholar, and Web of Science databases were selected for final consideration according to the PRISMA 2020 flow diagram. Included in our review were 17 prospective clinical studies, with at least 6 months of follow-up time. Corneal biomechanical properties were assessed by Ocular Response Analyzer (ORA), or Corvis ST. The results of the study revealed the highest corneal biomechanics reduction after laser in situ keratomileusis (LASIK) followed by small incision lenticule extraction (SMILE) and surface procedures, such as photorefractive keratectomy (PRK) or laser-assisted sub-epithelial keratectomy (LASEK). In SMILE procedure treatment planning, the use of thicker caps preserves the corneal biomechanics. Similarly, reduction of flap thickness in LASIK surgery maintains the corneal biomechanical strength. Future prospective clinical trials with standardization of the study groups and surgical parameters are needed to confirm the results of the current review.
Collapse
|
11
|
Quantitative Evaluation of In Vivo Corneal Biomechanical Properties after SMILE and FLEx Surgery by Acoustic Radiation Force Optical Coherence Elastography. SENSORS (BASEL, SWITZERLAND) 2022; 23:s23010181. [PMID: 36616779 PMCID: PMC9823345 DOI: 10.3390/s23010181] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 12/20/2022] [Accepted: 12/22/2022] [Indexed: 05/28/2023]
Abstract
The purpose of this study is to quantitatively evaluate the differences in corneal biomechanics after SMILE and FLEx surgery using an acoustic radiation force optical coherence elastography system (ARF-OCE) and to analyze the effect of the corneal cap on the integrity of corneal biomechanical properties. A custom ring array ultrasound transducer is used to excite corneal tissue to produce Lamb waves. Depth-resolved elastic modulus images of the in vivo cornea after refractive surgery were obtained based on the phase velocity of the Lamb wave. After refractive surgery, the average elastic modulus of the corneal flap decreased (71.7 ± 24.6 kPa), while the elastic modulus of the corneal cap increased (219.5 ± 54.9 kPa). The average elastic modulus of residual stromal bed (RSB) was increased after surgery, and the value after FLEx (305.8 ± 48.5 kPa) was significantly higher than that of SMILE (221.3 ± 43.2 kPa). Compared with FLEx, SMILE preserved most of the anterior stroma with less change in corneal biomechanics, which indicated that SMILE has an advantage in preserving the integrity of the corneal biomechanical properties. Therefore, the biomechanical properties of the cornea obtained by the ARF-OCE system may be one of the essential indicators for evaluating the safety of refractive surgery.
Collapse
|
12
|
Clinical outcomes of the immediate reapplication of small-incision lenticule extraction without adjusting the surgical parameters after suction loss. Sci Rep 2022; 12:15973. [PMID: 36153404 PMCID: PMC9509434 DOI: 10.1038/s41598-022-20403-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 09/13/2022] [Indexed: 11/23/2022] Open
Abstract
This study was to analyze the clinical outcomes of immediate reapplication of small-incision lenticule extraction (SMILE) without adjusting the surgical parameters after suction loss and to compare the outcomes with contralateral eyes that underwent uneventful SMILE. A total of 74 patients who underwent uneventful SMILE in one eye (Uneventful group) and immediate reapplication of SMILE without adjusting the surgical parameters after suction loss in the contralateral eye (Suction loss group) were included. Suction loss occurred during the posterior lenticule surface cut in 39 eyes (53%) and the cap cut in 35 eyes (47%). Surgical outcomes, including visual acuity, manifest refraction, keratometry, and corneal wavefront aberrations, were evaluated at 6 months postoperatively. The mean uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and spherical equivalent were − 0.02 ± 0.07, − 0.04 ± 0.04, and − 0.10 ± 0.46 diopters (D), respectively, in the Suction loss group and − 0.02 ± 0.07, − 0.04 ± 0.05, and − 0.19 ± 0.53 D, respectively (P = 0.965, 0.519, and 0.265, respectively), in the Uneventful group. Changes between the preoperative and 6-month postoperative total corneal aberrations, spherical aberrations, and horizontal and vertical coma did not significantly differ between the Suction loss and Uneventful groups. Immediate reapplication of SMILE without adjusting the surgical parameters after suction loss resulted in good surgical outcomes that were comparable with those of uneventful SMILE.
Collapse
|
13
|
Visual Outcomes of Small-Incision Lenticule Extraction (SMILE) in Thin Corneas. J Clin Med 2022; 11:jcm11144162. [PMID: 35887926 PMCID: PMC9324047 DOI: 10.3390/jcm11144162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 07/09/2022] [Accepted: 07/13/2022] [Indexed: 02/04/2023] Open
Abstract
We aimed to find out whether thin (≤500 μm) or normal (>500 μm, control) corneal thickness would impact efficacy and safety outcomes of small-incision lenticule extraction (SMILE). We retrospectively analyzed medical records of adult patients who had undergone SMILE. A total of 57 eyes were included in the “thin corneas” group and 180 eyes in the “control” group. At one month after surgery, rates of patients with uncorrected distance visual activity (UDVA) ≥ 0.8 were significantly higher in patients from the control group compared to the “thin corneas” group (87 vs. 71%, respectively p < 0.01), though rates were comparable at 3 months (87 vs. 76%, respectively, p > 0.05). SMILE had comparable safety in patients with thin and normal corneas. Procedure result predictability was comparable between groups. Regression analysis demonstrated that cap thickness impacted posterior corneal biomechanics, and the volume of removed tissue had a higher influence in patients with thin corneas. Moreover, an increase in cap thickness was associated with better final BCVA. Further study is needed for the evaluation of the impact of thin corneas on SMILE outcomes and planning. Our study also indicates that patients with thin corneas might require a different approach to nomogram calculation.
Collapse
|