1
|
Wang H, Masselos K, Tan JCK, Patel NB, Agar A, Kalloniatis M, Phu J. The frontloading approach to meet guideline-recommended visual field testing for glaucoma: time and cost. Ophthalmol Glaucoma 2025:S2589-4196(25)00071-7. [PMID: 40222604 DOI: 10.1016/j.ogla.2025.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2025] [Revised: 04/03/2025] [Accepted: 04/07/2025] [Indexed: 04/15/2025]
Abstract
PURPOSE To measure the time and clinical resources taken to obtain six reliable visual field (VF) tests for glaucoma in a glaucoma clinic. DESIGN Longitudinal, prospective study in a glaucoma clinic. SUBJECTS 10,010 SITA-Faster VF tests of 535 clinical subjects. METHODS The cumulative number of VF tests with false positive rates ≤15% for each eye of each subject was counted over time and from there, the time to achieve six VF tests was determined and compared under frontloaded (two VFs per eye per visit) and non-frontloaded (first VF within the frontloaded set) conditions. Costs to attain six VF tests were modelled. MAIN OUTCOME MEASURES VF counts and costs for attainment. RESULTS 8,931 of the 10,010 VF results had a false positive rate ≤15%. Approximately 90% of subjects had early or moderate open angle glaucoma. When using the frontloading protocol, it took an average of 1.4 years to attain 6 reliable VFs for right and left eyes, respectively. For the non-frontloaded protocol, the average times were 2.6 years and 2.5 years for right and left eyes, respectively. 82.5% of right eyes and 85.4% of left eyes achieved 6 reliable VFs within 2 years when frontloaded, but the proportion was only 15.8% and 18.8% when non-frontloaded for right and left eyes, respectively. There was a significantly lower cost for obtaining 6 reliable VFs with frontloading, compared to non-frontloading, due to fewer office visits. CONCLUSIONS A frontloading approach and SITA-Faster paradigm led to patients attaining 6 reliable VFs over 14 months sooner compared to non-frontloaded, with over 84% receiving the recommended number of 6 tests in the first 2 years. The frontloading approach overall leads to savings in time and cost in comparison to non-frontloading for achieving 6 reliable VFs, and thus potentially provides an avenue for earlier detection of glaucomatous change.
Collapse
Affiliation(s)
- Henrietta Wang
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia; Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia
| | - Katherine Masselos
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia; Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| | - Jeremy C K Tan
- Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia; Faculty of Medicine and Health, University of New South Wales, Kensington, NSW, Australia
| | - Nimesh B Patel
- College of Optometry, University of Houston, Houston, TX
| | - Ashish Agar
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia; Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia; Faculty of Medicine and Health, University of New South Wales, Kensington, NSW, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia; College of Optometry, University of Houston, Houston, TX; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| | - Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia; Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia; Faculty of Medicine and Health, University of Sydney, Sydney, NSW; Concord Clinical School, Concord Repatriation General Hospital, Concord, NSW.
| |
Collapse
|
2
|
Tan JCK, Yohannan J, Ramulu PY, Kalloniatis M, Crabb DP, Crowston J, Phu J. Visual field testing in glaucoma using the Swedish Interactive Thresholding Algorithm (SITA). Surv Ophthalmol 2025; 70:141-152. [PMID: 39349186 DOI: 10.1016/j.survophthal.2024.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 08/28/2024] [Accepted: 09/12/2024] [Indexed: 10/02/2024]
Abstract
The Swedish Interactive Thresholding Algorithm (SITA) is the main measurement acquisition algorithm used on the Humphrey Field Analyser, the most commonly used instrument for visual field (VF) assessment worldwide. We compare the sensitivity outputs and reliability parameters of the three currently available SITA algorithms-SITA Standard (SS), Fast (SF), and Faster (SFR), with a focus on the newly released SFR and the 24-2C test grid. SFR displays similar sensitivity outputs to SS and SF, but may not be interchangeable with SS in eyes with more severe VF loss. The reliability metric with the greatest impact on VF reliability is the level of false positives, although the recommended 15 % false positive cut off may be inappropriate as a threshold for judging whether a test is reliable and should be included for use in SFR. Finally, the 24-2C grid may be useful in flagging the presence of a clustered central VF defect, while the 10-2 grid can be used to more comprehensively characterize central field defects. We also discuss strategies to improve testing frequency in clinical practice.
Collapse
Affiliation(s)
- Jeremy C K Tan
- Faculty of Medicine and Health, University of New South Wales, Kensington, NSW, Australia; Optometry and Visual Sciences, City, University of London, Northampton Square, London, United Kingdom; Save Sight Institute, University of Sydney,Camperdown, NSW, Australia.
| | - Jithin Yohannan
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Pradeep Y Ramulu
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia; University of Houston College of Optometry, Houston, TX, USA
| | - David P Crabb
- Optometry and Visual Sciences, City, University of London, Northampton Square, London, United Kingdom
| | - Jonathan Crowston
- Save Sight Institute, University of Sydney,Camperdown, NSW, Australia; Singapore Eye Research Institute, DUKE-NUS Singapore, Singapore
| | - Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; Faculty of Medicine and Health, University of Sydney, NSW, Australia; Centre for Eye Health, UNSW, Sydney, NSW, Australia.
| |
Collapse
|
3
|
Phu J, Khuu SK, Nivison-Smith L, Kalloniatis M. Standard automated perimetry for glaucoma and diseases of the retina and visual pathways: Current and future perspectives. Prog Retin Eye Res 2025; 104:101307. [PMID: 39413870 DOI: 10.1016/j.preteyeres.2024.101307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 10/11/2024] [Accepted: 10/11/2024] [Indexed: 10/18/2024]
Abstract
Static automated perimetry (SAP) remains a mainstay of functional assessment of the visual field in diseases of the visual pathway, such as glaucoma and age-related macular degeneration. The fundamental psychophysical task of responding to stimuli of different levels of contrast has remained minimally changed since its inception in the 1980s, and this is potentially the root of several unresolved issues involving the technique. Enduring issues include the optimisation of SAP parameters for maximising defect detection, the influence of subjective behaviour on the response, structure-function discordance, and ageing- and disease-related changes of the visual pathway. Addressing these issues has been a focus of our research program and is the subject of this manuscript. We will review some of the basic psychophysical principles and methods that have contributed to the development of SAP and their contributions to its output measurements. Parameters that are interrogated include stimulus size and background luminance and their modification to improve defect defection in glaucoma and age-related macular degeneration. We propose frameworks for optimising testing parameters and leveraging the results for changing clinical care. In our pursuit of optimising the structure-function relationship in the eye, several areas of research have been developed and explored, including: the reconciliation of subjective responses in perimetry; by minimising sources of biases, such as Method of Limits we have been able to equate static and kinetic perimetry outputs in relation to underlying structural loci. This also formed the basis for our clustering framework, which groups together statistically similar structural and functional test locations to maximise structure-function concordance. Throughout the manuscript, we review the scientific underpinnings of clinical measurements, framing application into real-world patients to improve clinical practice.
Collapse
Affiliation(s)
- Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia; Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia; Concord Clinical School, Concord Repatriation General Hospital, Concord, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, VIC, Australia.
| | - Sieu K Khuu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia.
| | - Lisa Nivison-Smith
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, VIC, Australia; College of Optometry, University of Houston, Houston, TX, USA.
| |
Collapse
|
4
|
Phu J, Tan J, Kalloniatis M. Multiple (frontloaded) visual field tests increase identification of very slow mean deviation progression in glaucoma. CANADIAN JOURNAL OF OPHTHALMOLOGY 2024; 59:311-323. [PMID: 37652089 DOI: 10.1016/j.jcjo.2023.07.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 03/29/2023] [Accepted: 07/31/2023] [Indexed: 09/02/2023]
Abstract
OBJECTIVE To determine the effect of frontloading (multiple) visual field (VF) tests at the same visit for detecting mean deviation (MD) change in slowly progressive glaucoma. METHODS This was a computer simulation study. Baseline MD (range, 0 to -12 dB) and progression rate (range, 0 to -0.4 dB/year, non-inclusive) were generated for 10,000 patients. Each patient had 6 simulated "stable" baseline VF tests. Then follow-up VFs (up to 10 years) were generated by incorporating progression rate and within-visit and between-visit variability. The independent variables were number of VF tests per visit (one non-frontloaded or two frontloaded), VF reliability (100%, 85%, or 70%), repeat testing because of unreliable results (yes or no), and follow-up interval (6-monthly or yearly). The outcomes were detection of progression (MD slope that was negative and significant at p < 0.05), MD at detection, and number of years to detection. RESULTS Frontloading identified more progressors (62.7%-79.2%) compared with non-frontloading (31.0%-36.7%) at 10 years (p < 0.0001). Six-monthly follow-ups led to greater detection than yearly intervals. Progressors detected by both methods were detected by the non-frontloaded method sooner (up to 0.26 years), but this was small and not clinically significant (MD difference, 0.06 dB). An increase (less severe) in MD, an increase (slower) in progression rate, and an increase in SD of baseline VFs decreased the likelihood of detecting progression. CONCLUSIONS Frontloading VF tests at 6-monthly intervals improve detection rates of MD progression in slowly progressive glaucoma patients compared with performing 1 test per visit at yearly intervals.
Collapse
Affiliation(s)
- Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia; Faculty of Medicine and Health, University of Sydney, NSW, Australia; Centre for Eye Health, UNSW, Sydney, NSW, Australia.
| | - Jeremy Tan
- Faculty of Medicine and Health, University of New South Wales, Kensington, NSW, Australia; Department of Ophthalmology, Prince of Wales Hospital, Randwick, NSW, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| |
Collapse
|
5
|
Meyerov J, Chen Y, Busija L, Green C, Skalicky SE. Repeatability of Online Circular Contrast Perimetry Compared to Standard Automated Perimetry. J Glaucoma 2024; 33:505-515. [PMID: 38595156 DOI: 10.1097/ijg.0000000000002384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 02/16/2024] [Indexed: 04/11/2024]
Abstract
PRCIS Online circular contrast perimetry provides visual field assessment on any computer or tablet with no extra hardware. It has good test repeatability and reliability that is comparable with standard automated perimetry. It holds promise for use in disease screening and surveillance to expand the provision of glaucoma care. PURPOSE To evaluate the repeatability of online circular contrast perimetry (OCCP) compared to standard automated perimetry (SAP) in normal participants and patients with stable glaucoma over 18 weeks. METHODS Thirty-six participants (13 normal controls and 23 patients with open angle glaucoma) were recruited. OCCP and SAP perimetry tests were performed twice at baseline, then at 6, 12, and 18 weeks. Global perimetric indices were compared between perimetry types and analyzed for short-term and intermediate-term repeatability. RESULTS There were no statistically significant changes over time for both OCCP and SAP across all groups for mean deviation (MD), pattern standard deviation, and visual index/visual field index ( P >0.05). Test-retest intraclass correlation coefficients (ICCs) for OCCP MD were excellent at baseline (0.98, 95% CI: 0.89-0.99) and good at 18 weeks (0.88, 95% CI: 0.51-0.98). SAP test-retest ICCs were excellent at baseline (0.94, 95% CI: 0.70-0.99) and 18 weeks (0.97, 95% CI: 0.84-0.99). Inter-test ICCs were good, ranging from 0.84 to 0.87. OCCP testing time was shorter than SAP (5:29 ± 1:24 vs. 6:00 ± 1:05, P <0.001). OCCP had similar false-positive (3.84 ± 3.32 vs. 3.66 ± 4.53, P =0.48) but lower false-negative (0.73 ± 1.52 vs. 4.48 ± 5.00, P <0.001) and fixation loss responses (0.91 ± 1.32 vs. 2.02 ± 2.17, P <0.001). CONCLUSIONS OCCP allows visual field assessment on any computer screen with no additional hardware. It demonstrated good repeatability and reliability with similar performance indices to SAP in both the short term and intermediate term. OCCP has the potential to be utilized as a glaucoma screening and surveillance tool for in-clinic and at-home testing, expanding the provision of care.
Collapse
Affiliation(s)
- Joshua Meyerov
- Department of Ophthalmology, The Alfred Hospital, Alfred Health
| | - Yang Chen
- Department of Surgery Ophthalmology, University of Melbourne
| | - Lazar Busija
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Catherine Green
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| |
Collapse
|
6
|
Tan JCK, Agar A, Kalloniatis M, Phu J. Quantification and Predictors of Visual Field Variability in Healthy, Glaucoma Suspect, and Glaucomatous Eyes Using SITA-Faster. Ophthalmology 2024; 131:658-666. [PMID: 38110124 DOI: 10.1016/j.ophtha.2023.12.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 11/27/2023] [Accepted: 12/12/2023] [Indexed: 12/20/2023] Open
Abstract
PURPOSE The newly released Swedish Interactive Thresholding Algorithm (SITA)-Faster (SFR) has significantly shorter testing durations compared with older SITA algorithms, but its variability is uncertain. This study quantified and established threshold limits of test-retest variability across the 24-2 test grid using SFR. DESIGN Cross-sectional study with prospective longitudinal arm. PARTICIPANTS 1426 eyes of 787 patients with healthy, suspected glaucoma, or manifest glaucoma eyes from hospital- and university- eye clinics. METHODS Two SFR tests per eye at a baseline visit and at two follow-up visits. MAIN OUTCOME MEASURES Pointwise variability measured by test-retest difference in pointwise sensitivity between tests one and two, mean global variability (test-retest variance) measured by average of pointwise variability for each participant, global sensitivity, and reliability indices of each eye. RESULTS Of the 1426 eyes, 540 eyes (37.9%) had a diagnosis of glaucoma, 753 eyes (52.8%) were suspected of having glaucoma, and the remaining 133 eyes (9.3%) were healthy. Of 74 152 pointwise sensitivities obtained, the mean test-retest difference was 2.17 ± 2.9 dB, whereas the mean test-retest variance for each participant was 2.17 ± 1.2 dB. Pointwise and global variability increased with worsening threshold sensitivity and (MD), respectively, and was greater for peripheral compared with central test locations. In the longitudinal cohort, no significant difference in mean test-retest variance was found across the 3 visits (mean variability, 2.10 dB vs. 2.16 dB vs. 2.16 dB at visits F0 vs. F1 vs. F2; P = 0.53, repeated-measures analysis of variance). Baseline MD (-0.19 dB; 95% CI, -0.22 to 0.16 dB; P < 0.0001) and abnormally high sensitivity on glaucoma hemifield test (1.14 dB; 95% CI, 0.78-1.51 dB; P < 0.0001) were significantly associated with increased variability. Finally, test-retest MD showed minimal change around the recommended 15% false-positive cutoff threshold. CONCLUSIONS The variability of SFR increases with worsening threshold sensitivity, is stable over time, and is greater for peripheral compared with central test locations. Worse baseline MD and abnormally high sensitivity are significant predictors of increased variability. A cutoff of 15% in false-positive results may be inappropriate as a threshold for judging test reliability in SFR. FINANCIAL DISCLOSURE(S) The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Collapse
Affiliation(s)
- Jeremy C K Tan
- Faculty of Medicine and Health, University of New South Wales, Kensington, New South Wales, Australia; Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia.
| | - Ashish Agar
- Faculty of Medicine and Health, University of New South Wales, Kensington, New South Wales, Australia; Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| | - Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia; Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia; Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia.
| |
Collapse
|
7
|
Wu D, Lu J, Zheng N, Elsehrawy MG, Alfaiz FA, Zhao H, Alqahtani MS, Xu H. Utilizing nanotechnology and advanced machine learning for early detection of gastric cancer surgery. ENVIRONMENTAL RESEARCH 2024; 245:117784. [PMID: 38065392 DOI: 10.1016/j.envres.2023.117784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 11/20/2023] [Accepted: 11/23/2023] [Indexed: 01/06/2024]
Abstract
Nanotechnology has emerged as a promising frontier in revolutionizing the early diagnosis and surgical management of gastric cancers. The primary factors influencing curative efficacy in GIC patients are drug inefficacy and high surgical and pharmacological therapy recurrence rates. Due to its unique optical features, good biocompatibility, surface effects, and small size effects, nanotechnology is a developing and advanced area of study for detecting and treating cancer. Considering the limitations of GIC MRI and endoscopy and the complexity of gastric surgery, the early diagnosis and prompt treatment of gastric illnesses by nanotechnology has been a promising development. Nanoparticles directly target tumor cells, allowing their detection and removal. It also can be engineered to carry specific payloads, such as drugs or contrast agents, and enhance the efficacy and precision of cancer treatment. In this research, the boosting technique of machine learning was utilized to capture nonlinear interactions between a large number of input variables and outputs by using XGBoost and RNN-CNN as a classification method. The research sample included 350 patients, comprising 200 males and 150 females. The patients' mean ± SD was 50.34 ± 13.04 with a mean age of 50.34 ± 13.04. High-risk behaviors (P = 0.070), age at diagnosis (P = 0.034), distant metastasis (P = 0.004), and tumor stage (P = 0.014) were shown to have a statistically significant link with GC patient survival. AUC was 93.54%, Accuracy 93.54%, F1-score 93.57%, Precision 93.65%, and Recall 93.87% when analyzing stomach pictures. Integrating nanotechnology with advanced machine learning techniques holds promise for improving the diagnosis and treatment of gastric cancer, providing new avenues for precision medicine and better patient outcomes.
Collapse
Affiliation(s)
- Dan Wu
- Department of Gastrointestinal Surgery, Lishui Municipal Central Hospital, Lishui, 323000, Zhejiang, China
| | - Jianhua Lu
- Department of Gastrointestinal Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, 325000, China
| | - Nan Zheng
- School of Pharmacy, Wenzhou Medicine University, Wenzhou, 325000, China
| | - Mohamed Gamal Elsehrawy
- Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Kingdom of Saudi Arabia; Nursing Faculty, Port-Said University, Egypt.
| | - Faiz Abdulaziz Alfaiz
- Department of Biology, College of Science, Majmaah University, Al-Majmaah, 11952, Saudi Arabia.
| | - Huajun Zhao
- School of Pharmacy, Wenzhou Medicine University, Wenzhou, 325000, China.
| | - Mohammed S Alqahtani
- Radiological Sciences Department, College of Applied Medical Sciences, King Khalid University, Abha, 61421, Saudi Arabia; BioImaging Unit, Space Research Centre, Michael Atiyah Building, University of Leicester, Leicester, LE1 7RH, UK
| | - Hongtao Xu
- Department of Gastrointestinal Surgery, The Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, 323000, Zhejiang, China.
| |
Collapse
|
8
|
Wang H, Kalloniatis M, Tan JCK, Phu J. Frontloading visual field tests detect earlier mean deviation progression when applied to real-world-derived early-stage glaucoma data. Ophthalmic Physiol Opt 2024; 44:426-441. [PMID: 38226742 DOI: 10.1111/opo.13270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 11/20/2023] [Accepted: 12/21/2023] [Indexed: 01/17/2024]
Abstract
PURPOSE To examine the diagnostic accuracy of performing two (frontloaded) versus one (clinical standard) visual field (VF) test per visit for detecting the progression of early glaucoma in data derived from clinical populations. METHODS A computer simulation model was used to follow the VFs of 10,000 glaucoma patients (derived from two cohorts: Heijl et al., Swedish cohort; and Chauhan et al., Canadian Glaucoma Study [CGS]) over a 10-year period to identify patients whose mean deviation (MD) progression was detected. Core data (baseline MD and progression rates) were extracted from two studies in clinical cohorts of glaucoma, which were modulated using SITA-Faster variability characteristics from previous work. Additional variables included follow-up intervals (six-monthly or yearly) and rates of perimetric data loss for any reason (0%, 15% and 30%). The main outcome measures were the proportions of progressors detected. RESULTS When the Swedish cohort was reviewed six-monthly, the frontloaded strategy detected more progressors compared to the non-frontloaded method up to years 8, 9 and 10 of follow-up for 0%, 15% and 30% data loss conditions. The time required to detect 50% of cases was 1.0-1.5 years less for frontloading compared to non-frontloading. At 4 years, frontloading increased detection by 26.7%, 28.7% and 32.4% for 0%, 15% and 30% data loss conditions, respectively. Where both techniques detected progression, frontloading detected progressors earlier compared to the non-frontloaded strategy (78.5%-81.5% and by 1.0-1.3 years when reviewed six-monthly; 81%-82.9% and by 1.2-2.1 years when reviewed yearly). Accordingly, these patients had less severe MD scores (six-monthly review: 0.63-1.67 dB 'saved'; yearly review: 1.10-2.87 dB). The differences increased with higher rates of data loss. Similar tendencies were noted when applied to the CGS cohort. CONCLUSIONS Frontloaded VFs applied to clinical distributions of MD and progression led to earlier detection of early glaucoma progression.
Collapse
Affiliation(s)
- Henrietta Wang
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia
- School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
- School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| | - Jeremy C K Tan
- Faculty of Medicine and Health, University of New South Wales, Kensington, New South Wales, Australia
- Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| | - Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia
- School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
- Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
- Concord Clinical School, Concord Repatriation General Hospital, Concord, New South Wales, Australia
| |
Collapse
|
9
|
Phu J, Wang H, Kalloniatis M. Comparing a head-mounted virtual reality perimeter and the Humphrey Field Analyzer for visual field testing in healthy and glaucoma patients. Ophthalmic Physiol Opt 2024; 44:83-95. [PMID: 37803502 PMCID: PMC10952716 DOI: 10.1111/opo.13229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 08/16/2023] [Accepted: 08/23/2023] [Indexed: 10/08/2023]
Abstract
PURPOSE To compare clinical visual field outputs in glaucoma and healthy patients returned by the Humphrey Field Analyzer (HFA) and virtual reality (Virtual Field, VF) perimetry. METHODS One eye of 54 glaucoma patients and 41 healthy subjects was prospectively tested (three times each in random order) using the HFA and VF perimeters (24-2 test grids). We extracted and compared global indices (mean deviation [MD] and pattern standard deviation [PSD]), pointwise sensitivity (and calculated 'equivalent' sensitivity after accounting for differences in background luminance) and pointwise defects. Bland-Altman (mean difference [Mdiff ] and 95% limits of agreement [LoA]) and intraclass correlation analyses were performed. RESULTS The VF test was shorter (by 76 s) and had lower fixation losses (by 0.08) and false-positive rate (by 0.01) compared to the HFA (all p < 0.0001). Intraclass correlations were 0.86, 0.82 and 0.47 for MD, PSD and pointwise sensitivity between devices, respectively. Test-retest variability was higher for VF (Mdiff 0.3 dB, LoA -7.6 to 8.2 dB) compared to the HFA (Mdiff -0.3 dB, LoA -6.4 to 5.9 dB), indicating greater test-retest variability. When using each device's underlying normative database, the HFA detected, on average, 7 more defects (at the p < 0.05 level) out of the 52 test locations compared to this iteration of VF in the glaucoma cohort. CONCLUSIONS Virtual Field returns global results that are correlated with the HFA, but pointwise sensitivities were more variable. Differences in test-retest variability and defect detection by its current normative database raise questions about the widespread adoption of VF in lieu of the HFA.
Collapse
Affiliation(s)
- Jack Phu
- School of Optometry and Vision ScienceUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
- Centre for Eye HealthUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
- Faculty of Medicine and HealthUniversity of SydneyCamperdownNew South WalesAustralia
- Concord Clinical SchoolConcord Repatriation General HospitalConcordNew South WalesAustralia
- School of Medicine (Optometry)Deakin UniversityWaurn PondsVictoriaAustralia
| | - Henrietta Wang
- School of Optometry and Vision ScienceUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
- Centre for Eye HealthUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
| | - Michael Kalloniatis
- School of Optometry and Vision ScienceUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
- School of Medicine (Optometry)Deakin UniversityWaurn PondsVictoriaAustralia
| |
Collapse
|
10
|
Tan JCK, Phu J, Go D, Nguyen D, Masselos K, Bank A, Kalloniatis M, Agar A. Evaluation of the Consistency of Glaucomatous Visual Field Defects Using a Clustered SITA-Faster Protocol. Ophthalmology 2023; 130:1138-1148. [PMID: 37385298 DOI: 10.1016/j.ophtha.2023.06.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 06/20/2023] [Accepted: 06/21/2023] [Indexed: 07/01/2023] Open
Abstract
PURPOSE Frontloading SITA-Faster (SFR) visual fields (2 tests per eye on the same visit) has been shown to provide repeatable perimetric data at minimal time cost. This study reports the outcomes of using frontloaded SFR in the evaluation of pointwise visual field (VF) defects in a cohort of patients with glaucoma when transitioned from SITA-Standard (SS). DESIGN Prospective, cross-sectional study. PARTICIPANTS A total of 144 eyes of 91 patients with confirmed or suspected glaucoma who had an SS test on a previous visit. METHODS Two SFR tests (T1, T2) per eye on the same visit. MAIN OUTCOME MEASURES Global sensitivity, reliability indices, and pointwise deviation map probability scores from the pattern deviation grid of each patient were compared across the 3 sequential tests to evaluate the consistency of VF defects. RESULTS The mean age was 68.6 years, and 79.2% of patients had a diagnosis of glaucoma. There was no significant difference in mean deviation (MD) across the 3 tests (-5.83 decibels [dB], -5.28 dB, and -5.71 dB in SS, SFR1, and SFR2, respectively, repeated-measures analysis of variance [ANOVA], P = 0.48). The frontloaded SFR tests provided repeatable VFs that confirmed existing pointwise data on the SS in 4661 (62.3%) locations, reversed an SS defect in 614 (8.2%) locations, and demonstrated a new repeatable defect in 406 (5.4%) locations of the pattern deviation grid. A new defect of at least 3 contiguous points was identified in 20.1% of eyes. The non-repeatable points on the 2 SFR tests displayed no significant difference in the distribution of defect/nondefect points based on test order or peripheral versus central locations. There was no significant difference in the rate of obtaining at least 1 reliable test result between SS and the frontloaded SFR T1 and T2 (P = 0.77). Test duration significantly decreased from SS to SFR1/2 (379 vs. 160 vs. 158 seconds, P < 0.0001). CONCLUSIONS Frontloading SFR tests can provide repeatable data for the evaluation of the consistency of pattern deviation defects in glaucoma, with no observable decline in performance from test fatigue. This is achieved at equivalent duration and reliability as a single SS test. Frontloading SFR may be helpful in increasing testing frequency/quantity to meet recommended guidelines for progression analysis. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Jeremy C K Tan
- Faculty of Medicine and Health, University of New South Wales, Kensington, New South Wales, Australia; Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia.
| | - Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia; Faculty of Medicine and Health, University of Sydney, New South Wales, Australia; Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia
| | - Denise Go
- Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| | - Doan Nguyen
- Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| | - Katherine Masselos
- Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia; Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia
| | - Allan Bank
- Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| | - Ashish Agar
- Faculty of Medicine and Health, University of New South Wales, Kensington, New South Wales, Australia; Department of Ophthalmology, Prince of Wales Hospital, Randwick, New South Wales, Australia
| |
Collapse
|
11
|
Tan JCK, Kalloniatis M, Phu J. Frontloading SITA-Faster Can Increase Frequency and Reliability of Visual Field Testing at Minimal Time Cost. Ophthalmol Glaucoma 2023; 6:445-456. [PMID: 36958625 DOI: 10.1016/j.ogla.2023.03.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 03/04/2023] [Accepted: 03/15/2023] [Indexed: 03/25/2023]
Abstract
PURPOSE To report the outcomes of frontloaded visual field (VF) testing (2 tests per eye on the same visit) over 2 longitudinal, consecutive visits using SITA-Faster (SFR) in terms of global indices, reliability metrics, and test duration. DESIGN Prospective longitudinal study. SUBJECTS A total of 902 eyes of 463 subjects with normal, suspect, or manifest glaucoma. METHODS Two intravisit SFR VF tests (T1 and T2) per eye at an initial (Ti) and follow-up (Tf) visit. MAIN OUTCOME MEASURES Intra- and intervisit global indices, reliability metrics, and test durations. RESULTS The mean age of the subjects was 63.6 years, and 58.3% were male. Seven hundred ninety eyes (87.4%) had a diagnosis of glaucoma or glaucoma suspicion. The mean duration between visits was 265.0 (standard deviation 98.8) days. In total, 3608 VF tests were analyzed, with the correlation of mean deviation (MD) values of the frontloaded tests at each visit high (T1/T2 MD correlation at initial visit r = 0.83, root mean squared error [RMSE] = 1.26, follow-up visit r = 0.83, RMSE = 1.25, P < 0.0001) and greater than the correlation of MD between visits (Ti1/Tf1 MD correlation r = 0.72, RMSE = 1.31). There was a significant intra-visit decrease in rates of abnormally high sensitivity in the glaucoma hemifield test (3.2% vs. 1.6%, P = 0.0023) and rates of unreliable test results (15.4% vs. 9.2%, P = 0.002) from T1 to T2 in both visits, with a corresponding significant decrease in MD (-1.28 dB vs. -1.68 dB, P < 0.0001) and VF index (P = 0.03). The mean duration of each SFR test was 132.6 (SD 27.2) seconds. CONCLUSIONS Frontloading VFs using SFR produced sets of repeatable perimetric data with significant improvement of reliability indices from the first to second test. This may help increase testing frequency at minimal time cost to meet recommended guidelines and for evaluating patients prone to high variability. FINANCIAL DISCLOSURE(S) The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Collapse
Affiliation(s)
- Jeremy C K Tan
- Faculty of Medicine and Health, University of New South Wales, Kensington, NSW, Australia; Department of Ophthalmology, Prince of Wales Hospital, Randwick, NSW, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, Victoria, Australia
| | - Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia; Centre for Eye Health, UNSW, Sydney, NSW, Australia; Concord Clinical School, Concord Repatriation General Hospital, Concord, NSW, Australia.
| |
Collapse
|
12
|
Lee GA, Kong GYX, Liu CH. Visual fields in glaucoma: Where are we now? Clin Exp Ophthalmol 2023; 51:162-169. [PMID: 36751125 DOI: 10.1111/ceo.14210] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 01/25/2023] [Accepted: 02/03/2023] [Indexed: 02/09/2023]
Abstract
Visual fields are an integral part of glaucoma diagnosis and management. COVID has heightened the awareness of the potential for viral spread with the practice of visual fields modified. Mask artefacts can occur due to fogging of the inferior rim of the trail lens. Fortunately, the risk of airborne transmission when field testing is low. The 24-2c may be useful to detect early disease and the 10-2 more sensitive to detect advanced loss. The SITA faster test algorithm is able to reduce testing time thereby improving clinic efficiency, however, may show milder results for moderate or severe glaucoma. The technician has an important role of supervising the visual field performance to achieve reliable output. Home monitoring can provide earlier detection of progression and thus improve monitoring of glaucoma as well as reduce the burden of in-clinic assessments. Artificial Intelligence has been found to have high sensitivity and specificity compared to expert observers in detecting field abnormalities and progression as well as integrating structure with function. Although these advances will improve efficiency and guide accuracy, there will remain a need for clinicians to interpret the results and instigate management.
Collapse
Affiliation(s)
- Graham A Lee
- City Eye Centre, Brisbane, Queensland, Australia.,University of Queensland, Herston, Queensland, Australia.,Department of Ophthalmology, Mater Hospital, Brisbane, Queensland, Australia
| | - George Y X Kong
- Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital VIC, East Melbourne, Victoria, Australia.,Centre for Eye Research Australia, Royal Victorian Eye, and Ear Hospital, East Melbourne, Victoria, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Parkville, Victoria, Australia
| | | |
Collapse
|
13
|
Meyerov J, Deng Y, Busija L, Bigirimana D, Skalicky SE. Online Circular Contrast Perimetry: A Comparison to Standard Automated Perimetry. Asia Pac J Ophthalmol (Phila) 2023; 12:4-15. [PMID: 36706329 DOI: 10.1097/apo.0000000000000589] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 10/30/2022] [Indexed: 01/29/2023] Open
Abstract
PURPOSE The aim was to validate and compare the diagnostic accuracy of a novel 24-degree, 52-loci online circular contrast perimetry (OCCP) application to standard automated perimetry (SAP). DESIGN Prospective cohort study. METHODS Two hundred and twenty participants (125 normal controls, 95 open angle glaucoma patients) were included. Agreement, correlation, sensitivity, specificity, and area under receiver operating curves (AUC) were compared for parameters of OCCP, SAP, and optical coherence tomography (OCT) for the retinal nerve fiber layer and macular ganglion cell complex inner plexiform layer. RESULTS Pointwise sensitivity for OCCP was greater than SAP by 1.02 log units (95% CI: 0.95-1.08); 95% limits of agreement 0.860 to 1.17. Correlation and agreement for global indices and regional zones between OCCP and SAP were strong. OCCP mean deviation (MD) AUC was 0.885±0.08, similar to other instruments' parameters with the highest AUC: SAP MD (0.851±0.08), OCT retinal nerve fiber layer inferior thickness (0.908±0.07), OCT ganglion cell complex inner plexiform layer inferior thickness (0.849±0.08), P>0.05. At best cutoff, OCCP MD sensitivity/specificity were comparable to SAP MD (90/74 vs 94/65%). CONCLUSIONS OCCP demonstrates similar perimetric sensitivities to SAP and similar AUC to SAP and OCT in distinguishing glaucoma patients from controls. OCCP holds promise as a glaucoma surveillance and screening tool, with the potential to be utilized for in-clinic and at-home perimetry and expand community testing.
Collapse
Affiliation(s)
- Joshua Meyerov
- St Vincent's Hospital Clinical School, University of Melbourne, Melbourne, Vic., Australia
| | - Yuanchen Deng
- St Vincent's Hospital Clinical School, University of Melbourne, Melbourne, Vic., Australia
| | - Lazar Busija
- Glaucoma Investigation and Research Unit, the Royal Victorian Eye and Ear Hospital, Melbourne, Vic., Australia
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, Vic., Australia
| | - Deus Bigirimana
- Glaucoma Investigation and Research Unit, the Royal Victorian Eye and Ear Hospital, Melbourne, Vic., Australia
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, Vic., Australia
| | - Simon E Skalicky
- Glaucoma Investigation and Research Unit, the Royal Victorian Eye and Ear Hospital, Melbourne, Vic., Australia
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, Vic., Australia
| |
Collapse
|
14
|
Phu J, Kalloniatis M. Gaze tracker parameters have little association with visual field metrics of intrasession frontloaded SITA-Faster 24-2 visual field results. Ophthalmic Physiol Opt 2022; 42:973-985. [PMID: 35598152 PMCID: PMC9542222 DOI: 10.1111/opo.13006] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 04/27/2022] [Accepted: 04/28/2022] [Indexed: 11/03/2022]
Abstract
PURPOSE To determine the usefulness of Humphrey Field Analyser (HFA) SITA-Faster 24-2 gaze tracker outputs on interpreting intra-visit visual field (VF) result pairs. METHODS Analysis of 1380 right-left eye pairs and 1432 pairs of test 1-test 2 intrasession VF results of patients seen within a university-based glaucoma service was undertaken to understand gaze deviation distributions. Output gaze tracker results were aggregated into total ticks, sum of amplitudes and average amplitudes. Correlations between visual field indices (mean deviation [MD], "events" and overall hill of vision) and independent variables (age and test order) were performed using one eye from each subject. RESULTS There was no association of test order (right-left, test 1-test 2) with eye movements. There was a significant, but weak correlation between eye movements and age (r = 0.16). Correlations of eye movements with MD were driven by more severe MD values. There were no significant correlations between intrasession difference in eye movements and the change in MD, number of "events" and hill of vision, or in the root mean square of sensitivity and total deviation values. There was also no significant correlation between gaze tracker outputs and another commonly used "reliability" metric, false positive rate. CONCLUSIONS Eye movement parameters as currently reported by the HFA do not appear to be correlated with key sensitivity parameters when considering the repeatability of intrasession SITA-Faster 24-2 VF results. Thus, current gaze tracker outputs do not appear to provide clinically meaningful information for interpretation of intra-visit visual field results that cannot already be garnered using other strategies.
Collapse
Affiliation(s)
- Jack Phu
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, University of New South Wales, Kensington, New South Wales, Australia.,School of Optometry and Vision Science, University of New South Wales, Kensington, New South Wales, Australia
| |
Collapse
|