1
|
Clarke H, Leav S, Zestic J, Mohamed I, Salisbury I, Sanderson P. Enhanced Neonatal Pulse Oximetry Sounds for the First Minutes of Life: A Laboratory Trial. HUMAN FACTORS 2024; 66:1017-1036. [PMID: 35993422 DOI: 10.1177/00187208221118472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
OBJECTIVE Auditory enhancements to the pulse oximetry tone may help clinicians detect deviations from target ranges for oxygen saturation (SpO2) and heart rate (HR). BACKGROUND Clinical guidelines recommend target ranges for SpO2 and HR during neonatal resuscitation in the first 10 minutes after birth. The pulse oximeter currently maps HR to tone rate, and SpO2 to tone pitch. However, deviations from target ranges for SpO2 and HR are not easy to detect. METHOD Forty-one participants were presented with 30-second simulated scenarios of an infant's SpO2 and HR levels in the first minutes after birth. Tremolo marked distinct HR ranges and formants marked distinct SpO2 ranges. Participants were randomly allocated to conditions: (a) No Enhancement control, (b) Enhanced HR Only, (c) Enhanced SpO2 Only, and (d) Enhanced Both. RESULTS Participants in the Enhanced HR Only and Enhanced SpO2 Only conditions identified HR and SpO2 ranges, respectively, more accurately than participants in the No Enhancement condition, ps < 0.001. In the Enhanced Both condition, the tremolo enhancement of HR did not affect participants' ability to identify SpO2 range, but the formants enhancement of SpO2 may have attenuated participants' ability to identify tremolo-enhanced HR range. CONCLUSION Tremolo and formant enhancements improve range identification for HR and SpO2, respectively, and could improve clinicians' ability to identify SpO2 and HR ranges in the first minutes after birth. APPLICATION Enhancements to the pulse oximeter tone to indicate clinically important ranges could improve the management of oxygen delivery to the neonate during resuscitation in the first 10 minutes after birth.
Collapse
Affiliation(s)
- Hugh Clarke
- School of Psychology, The University of Queensland, St Lucia, QLD, Australia
| | - Samnang Leav
- School of Psychology, The University of Queensland, St Lucia, QLD, Australia
| | - Jelena Zestic
- School of Psychology, The University of Queensland, St Lucia, QLD, Australia
| | - Ismail Mohamed
- School of Psychology, The University of Queensland, St Lucia, QLD, Australia
| | - Isaac Salisbury
- School of Psychology, The University of Queensland, St Lucia, QLD, Australia
| | - Penelope Sanderson
- School of Psychology
- School of Information Technology and Electrical Engineering, and
- School of Clinical Medicine, The University of Queensland, St Lucia, QLD, Australia
| |
Collapse
|
2
|
Sanderson PM, Loeb RG, Liley H, Liu D, Paterson E, Hinckfuss K, Zestic J. Signaling Patient Oxygen Desaturation with Enhanced Pulse Oximetry Tones. Biomed Instrum Technol 2022; 56:46-57. [PMID: 35671368 PMCID: PMC9767428 DOI: 10.2345/0899-8205-56.2.46] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Manufacturers could improve the pulse tones emitted by pulse oximeters to support more accurate identification of a patient's peripheral oxygen saturation (SpO2) range. In this article, we outline the strengths and limitations of the variable-pitch tone that represents SpO2 of each detected pulse, and we argue that enhancements to the tone to demarcate clinically relevant ranges are feasible and desirable. The variable-pitch tone is an appreciated and trusted feature of the pulse oximeter's user interface. However, studies show that it supports relative judgments of SpO2 trends over time and is less effective at supporting absolute judgments about the SpO2 number or conveying when SpO2 moves into clinically important ranges. We outline recent studies that tested whether acoustic enhancements to the current tone could convey clinically important ranges more directly, without necessarily using auditory alarms. The studies cover the use of enhanced variable-pitch pulse oximeter tones for neonatal and adult use. Compared with current tones, the characteristics of the enhanced tones represent improvements that are both clinically relevant and statistically significant. We outline the benefits of enhanced tones, as well as discuss constraints of which developers of enhanced tones should be aware if enhancements are to be successful.
Collapse
Affiliation(s)
- Penelope M Sanderson
- Penelope M. Sanderson, PhD, is professor of cognitive engineering and human factors in the Schools of Psychology, Clinical Medicine, and Information Technology and Electrical Engineering at The University of Queensland in Queensland, Australia.
| | - Robert G Loeb
- Robert G. Loeb, MD, is an honorary professor in the School of Psychology at The University of Queensland in Queensland, Australia, and an emeritus clinical professor at University of Florida-Gainesville
| | - Helen Liley
- Helen Liley, MBCh, FRACP, is a senior staff specialist at Mater Mothers' Hospital and a professor in the Faculty of Medicine at The University of Queensland in Queensland, Australia
| | - David Liu
- David Liu, MBBS, PhD, is an anaesthetics registrar at Sunshine Coast University Hospital in Queensland, Australia, and a senior lecturer in the Faculty of Medicine at The University of Queensland in Queensland, Australia
| | - Estrella Paterson
- Estrella Paterson, PhD, is a postdoctoral fellow in the School of Psychology at The University of Queensland in Queensland, Australia
| | - Kelly Hinckfuss
- Kelly Hinckfuss, MPhil, is a clinical masters student in the School of Psychology at The University of Queensland in Queensland, Australia
| | - Jelena Zestic
- Jelena Zestic, PhD, is a human systems engineer at Boeing Research and Technology in Brisbane, Australia
| |
Collapse
|
3
|
Sanderson PM, Loeb RG, Liley H, Liu D, Paterson E, Hinckfuss K, Zestic J. Signaling Patient Oxygen Desaturation with Enhanced Pulse Oximetry Tones. Biomed Instrum Technol 2022. [PMID: 35671368 DOI: 10.2345/1943-5967-56.2.46] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Manufacturers could improve the pulse tones emitted by pulse oximeters to support more accurate identification of a patient's peripheral oxygen saturation (SpO2) range. In this article, we outline the strengths and limitations of the variable-pitch tone that represents SpO2 of each detected pulse, and we argue that enhancements to the tone to demarcate clinically relevant ranges are feasible and desirable. The variable-pitch tone is an appreciated and trusted feature of the pulse oximeter's user interface. However, studies show that it supports relative judgments of SpO2 trends over time and is less effective at supporting absolute judgments about the SpO2 number or conveying when SpO2 moves into clinically important ranges. We outline recent studies that tested whether acoustic enhancements to the current tone could convey clinically important ranges more directly, without necessarily using auditory alarms. The studies cover the use of enhanced variable-pitch pulse oximeter tones for neonatal and adult use. Compared with current tones, the characteristics of the enhanced tones represent improvements that are both clinically relevant and statistically significant. We outline the benefits of enhanced tones, as well as discuss constraints of which developers of enhanced tones should be aware if enhancements are to be successful.
Collapse
Affiliation(s)
- Penelope M Sanderson
- Penelope M. Sanderson, PhD, is professor of cognitive engineering and human factors in the Schools of Psychology, Clinical Medicine, and Information Technology and Electrical Engineering at The University of Queensland in Queensland, Australia.
| | - Robert G Loeb
- Robert G. Loeb, MD, is an honorary professor in the School of Psychology at The University of Queensland in Queensland, Australia, and an emeritus clinical professor at University of Florida-Gainesville
| | - Helen Liley
- Helen Liley, MBCh, FRACP, is a senior staff specialist at Mater Mothers' Hospital and a professor in the Faculty of Medicine at The University of Queensland in Queensland, Australia
| | - David Liu
- David Liu, MBBS, PhD, is an anaesthetics registrar at Sunshine Coast University Hospital in Queensland, Australia, and a senior lecturer in the Faculty of Medicine at The University of Queensland in Queensland, Australia
| | - Estrella Paterson
- Estrella Paterson, PhD, is a postdoctoral fellow in the School of Psychology at The University of Queensland in Queensland, Australia
| | - Kelly Hinckfuss
- Kelly Hinckfuss, MPhil, is a clinical masters student in the School of Psychology at The University of Queensland in Queensland, Australia
| | - Jelena Zestic
- Jelena Zestic, PhD, is a human systems engineer at Boeing Research and Technology in Brisbane, Australia
| |
Collapse
|
4
|
Paterson E, Sanderson PM, Salisbury IS, Burgmann FP, Mohamed I, Loeb RG, Paterson NA. Evaluation of an enhanced pulse oximeter auditory display: a simulation study. Br J Anaesth 2020; 125:826-834. [DOI: 10.1016/j.bja.2020.05.038] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 05/11/2020] [Accepted: 05/21/2020] [Indexed: 10/23/2022] Open
|
5
|
Paterson E, Sanderson PM, Brecknell B, Paterson NAB, Loeb RG. Comparison of Standard and Enhanced Pulse Oximeter Auditory Displays of Oxygen Saturation. Anesth Analg 2019; 129:997-1004. [DOI: 10.1213/ane.0000000000004267] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
6
|
Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting. Anesthesiol Res Pract 2019; 2019:5914305. [PMID: 31428146 PMCID: PMC6679872 DOI: 10.1155/2019/5914305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Accepted: 06/04/2019] [Indexed: 11/23/2022] Open
Abstract
Background Anesthesia providers may need to interpret the output of vital sign monitors based on auditory cues, in the context of multitasking in the operating room. This study aims to evaluate the ability of different anesthesia providers to estimate heart rate and oxygen saturation in a simulation setting. Methods Sixty anesthesia providers (residents, nurse anesthetics, and anesthesiologists) were studied. Four scenarios were arranged in a simulation context. Two baseline scenarios with and without waveform visual aid, and two scenarios with variation of heart rate and/or oxygen saturation were used to assess the accuracy of the estimation made by the participants. Results When the accurate threshold for the heart rate was set at less than 5 beats per minute, the providers only had a correct estimation at two baseline settings with visual aids (p=0.22 and 0.2237). Anesthesia providers tend to underestimate the heart rate when it increases. Providers failed to accurately estimate oxygen saturation with or without visual aid (p=0.0276 and 0.0105, respectively). Change in recording settings significantly affected the accuracy of heart rate estimation (p < 0.0001), and different experience levels affected the estimation accuracy (p=0.041). Conclusion The ability of anesthesia providers with different levels of experience to assess baseline and variations of heart rate and oxygen saturation is unsatisfactory, especially when oxygen desaturation and bradycardia coexist, and when the subject has less years of experience.
Collapse
|
7
|
Klueber S, Wolf E, Grundgeiger T, Brecknell B, Mohamed I, Sanderson P. Supporting multiple patient monitoring with head-worn displays and spearcons. APPLIED ERGONOMICS 2019; 78:86-96. [PMID: 31046963 DOI: 10.1016/j.apergo.2019.01.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 01/17/2019] [Accepted: 01/18/2019] [Indexed: 06/09/2023]
Abstract
In hospitals, clinicians often need to monitor several patients while performing other tasks. However, visual displays that show patients' vital signs are in fixed locations and auditory alarms intended to alert clinicians may be missed. Information such as spearcons (time-compressed speech earcons) that 'travels' with the clinician and is delivered by earpiece and/or head-worn displays (HWDs), might overcome these problems. In this study, non-clinicians monitored five simulated patients in three 10-min scenarios while performing a demanding tracking task. Monitoring accuracy was better for participants using spearcons and a HWD (88.7%) or a HWD alone (86.2%) than for participants using spearcons alone (74.1%). Participants using the spearcons and HWD (37.7%) performed the tracking task no differently from participants using spearcons alone (37.1%) but participants using the HWD alone performed worse overall (33.1%). The combination of both displays may be a suitable solution for monitoring multiple patients.
Collapse
Affiliation(s)
- Sara Klueber
- Institute Human-Computer-Media, University of Würzburg, Germany.
| | - Erik Wolf
- Institute Human-Computer-Media, University of Würzburg, Germany
| | | | - Birgit Brecknell
- School of Psychology, The University of Queensland, Brisbane, Australia
| | - Ismail Mohamed
- School of Psychology, The University of Queensland, Brisbane, Australia
| | - Penelope Sanderson
- School of Psychology, The University of Queensland, Brisbane, Australia; School of Medicine and School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia
| |
Collapse
|
8
|
Zestic J, Brecknell B, Liley H, Sanderson P. A Novel Auditory Display for Neonatal Resuscitation: Laboratory Studies Simulating Pulse Oximetry in the First 10 Minutes After Birth. HUMAN FACTORS 2019; 61:119-138. [PMID: 30260681 DOI: 10.1177/0018720818793769] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
OBJECTIVE We tested whether enhanced sonifications would improve participants' ability to judge the oxygen saturation levels (SpO2) of simulated neonates in the first 10 min after birth. BACKGROUND During the resuscitation of a newborn infant, clinicians must keep the neonate's SpO2 levels within the target range, however the boundaries for the target range change each minute during the first 10 min after birth. Resuscitation places significant demand on the clinician's visual attention, and the pulse oximeter's sonification could provide eyes-free monitoring. However, clinicians have difficulty judging SpO2 levels using the current sonification. METHOD In two experiments, nonclinicians' ability to detect SpO2 range and direction-while performing continuous arithmetic problems-was tested with enhanced versus conventional sonifications. In Experiment 1, tremolo signaled when SpO2 had deviated below or above the target range. In Experiment 2, tremolo plus brightness signaled when SpO2 was above target range, and tremolo alone when SpO2 was below target range. RESULTS The tremolo sonification improved range identification accuracy over the conventional display (81% vs. 63%, p < .001). The tremolo plus brightness sonification further improved range identification accuracy over the conventional display (92% vs. 62%, p <.001). In both experiments, there was no difference across conditions in arithmetic task accuracy ( p >.05). CONCLUSION Using the enhanced sonifications, participants identified SpO2 range more accurately despite a continuous distractor task. APPLICATION An enhanced pulse oximetry sonification could help clinicians multitask more effectively during neonatal resuscitations.
Collapse
Affiliation(s)
| | | | - Helen Liley
- The University of Queensland, St Lucia, Australia
| | | |
Collapse
|
9
|
Aoki T, Inoue M, Miyasaka K. Audible capnometric cues with end-tidal carbon dioxide improve the quality of patient monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2017:4305-4308. [PMID: 29060849 DOI: 10.1109/embc.2017.8037808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The importance of capnometry and end-tidal carbon dioxide (ETCO2) has been underscored in recent years by guidelines as a method to continuously monitor adequacy of ventilation during sedation and anesthesia. Guidelines for cardiopulmonary resuscitation (CPR) recommend attempts to improve CPR quality if ETCO2 is lower than 10 mmHg. ETCO2 is thus a time-critical parameter that may benefit from being delivered in real time to health care providers. We performed a pilot study to investigate whether the addition of audible capnometric cues after each breath enhanced providers' ability to maintain appropriate ventilation over conventional capnography. The addition of audible cues was confirmed to enhance control of ETCO2 during manual ventilation. We subsequently developed five distinct audible capnometric cues corresponding to different levels of ETCO2. We performed a study using ten random simulated test cases to confirm whether changes between levels as well as the direction of change could be distinguished using these audible cues. Audible cues were found to be easily distinguishable. 16 evaluators correctly identified presence and direction of change in ETCO2 with an average pass rate of 89%. It is anticipated that this "ETCO2 Audible Cue" feature will be able to improve the quality of patient monitoring, as well help improve the quality of CPR.
Collapse
|
10
|
Paterson E, Sanderson P, Paterson N, Loeb R. Effectiveness of enhanced pulse oximetry sonifications for conveying oxygen saturation ranges: a laboratory comparison of five auditory displays. Br J Anaesth 2017; 119:1224-1230. [DOI: 10.1093/bja/aex343] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/01/2017] [Indexed: 11/14/2022] Open
|
11
|
Deschamps ML, Sanderson P, Hinckfuss K, Browning C, Loeb RG, Liley H, Liu D. Improving the detectability of oxygen saturation level targets for preterm neonates: A laboratory test of tremolo and beacon sonifications. APPLIED ERGONOMICS 2016; 56:160-169. [PMID: 27184324 DOI: 10.1016/j.apergo.2016.03.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2015] [Revised: 03/22/2016] [Accepted: 03/23/2016] [Indexed: 06/05/2023]
Abstract
Recent guidelines recommend oxygen saturation (SpO2) levels of 90%-95% for preterm neonates on supplemental oxygen but it is difficult to discern such levels with current pulse oximetry sonifications. We tested (1) whether adding levels of tremolo to a conventional log-linear pulse oximetry sonification would improve identification of SpO2 ranges, and (2) whether adding a beacon reference tone to conventional pulse oximetry confuses listeners about the direction of change. Participants using the Tremolo (94%) or Beacon (81%) sonifications identified SpO2 range significantly more accurately than participants using the LogLinear sonification (52%). The Beacon sonification did not confuse participants about direction of change. The Tremolo sonification may have advantages over the Beacon sonification for monitoring SpO2 of preterm neonates, but both must be further tested with clinicians in clinically representative scenarios, and with different levels of ambient noise and distractions.
Collapse
Affiliation(s)
| | - Penelope Sanderson
- School of Psychology, The University of Queensland, Australia; School of ITEE, The University of Queensland, Australia; School of Medicine, The University of Queensland, Australia.
| | - Kelly Hinckfuss
- School of Psychology, The University of Queensland, Australia
| | | | - Robert G Loeb
- Department of Anesthesiology, University of Arizona, USA
| | - Helen Liley
- School of Medicine, The University of Queensland, Australia; Mater Mothers Hospital, Australia
| | - David Liu
- School of ITEE, The University of Queensland, Australia; School of Medicine, The University of Queensland, Australia
| |
Collapse
|
12
|
|
13
|
Affiliation(s)
- Joseph Schlesinger
- From the Departments of Anesthesiology, Biomedical Engineering, and Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
14
|
Paterson E, Sanderson PM, Paterson NAB, Liu D, Loeb RG. The effectiveness of pulse oximetry sonification enhanced with tremolo and brightness for distinguishing clinically important oxygen saturation ranges: a laboratory study. Anaesthesia 2016; 71:565-72. [DOI: 10.1111/anae.13424] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/27/2016] [Indexed: 10/22/2022]
Affiliation(s)
- E. Paterson
- School of Psychology The University of Queensland Brisbane Queensland Australia
| | - P. M. Sanderson
- Schools of ITEE, Psychology, and Medicine The University of Queensland Brisbane Queensland Australia
| | | | - D. Liu
- School of ITEE The University of Queensland Brisbane Queensland Australia
| | - R. G. Loeb
- Department of Anesthesiology College of Medicine University of Arizona Arizona Tucson USA
| |
Collapse
|
15
|
Hinckfuss K, Sanderson P, Loeb RG, Liley HG, Liu D. Novel Pulse Oximetry Sonifications for Neonatal Oxygen Saturation Monitoring: A Laboratory Study. HUMAN FACTORS 2016; 58:344-359. [PMID: 26715687 DOI: 10.1177/0018720815617406] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2015] [Accepted: 10/11/2015] [Indexed: 06/05/2023]
Abstract
OBJECTIVE We aimed to test whether the use of novel pulse oximetry sounds (sonifications) better informs listeners when a neonate's oxygen saturation (SpO2) deviates from the recommended range. BACKGROUND Variable-pitch pulse oximeters do not accurately inform clinicians via sound alone when SpO2 is outside the target range of 90% to 95% for neonates on supplemental oxygen. Risk of blindness, organ damage, and death increase if SpO2 remains outside the target range. A more informative sonification may improve clinicians' ability to maintain the target range. METHOD In two desktop experiments, nonclinicians' ability to detect SpO2 range and direction of change was tested with novel versus conventional sonifications of simulated patient data. In Experiment 1, a "shoulder" sonification used larger pitch differences between adjacent saturation percentages for SpO2 values outside the target range. In Experiment 2, a "beacon" sonification used equal-appearing pitch differences, but when SpO2 was outside the target range, a fixed-pitch reference tone from the center of the target SpO2 range preceded every fourth pulse tone. RESULTS The beacon sonification improved range identification accuracy over the control display (85% vs. 60%; p < .001), but the shoulder sonification did not (55% vs. 52%). CONCLUSION The beacon provided a distinct auditory alert and reference that significantly improved nonclinical participants' ability to identify SpO2 range. APPLICATION Adding a beacon to the variable-pitch pulse oximeter sound may help clinicians identify when, and by how much, a neonate's SpO2 deviates from the target range, particularly during patient transport situations when auditory information becomes essential.
Collapse
Affiliation(s)
- Kelly Hinckfuss
- The University of Queensland, St. Lucia, AustraliaUniversity of Arizona, TucsonMater Mothers' Hospital, Brisbane, AustraliaThe University of Queensland, St. Lucia, Australia
| | | | | | | | - David Liu
- The University of Queensland, St. Lucia, Australia
| |
Collapse
|
16
|
Brown Z, Edworthy J, Sneyd JR, Schlesinger J. A comparison of linear and logarithmic auditory tones in pulse oximeters. APPLIED ERGONOMICS 2015; 51:350-357. [PMID: 26154232 DOI: 10.1016/j.apergo.2015.06.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2012] [Revised: 06/04/2015] [Accepted: 06/05/2015] [Indexed: 06/04/2023]
Abstract
This study compared the ability of forty anaesthetists to judge absolute levels of oxygen saturation, direction of change, and size of change in saturation using auditory pitch and pitch difference in two laboratory-based studies that compared a linear pitch scale with a logarithmic scale. In the former the differences in saturation become perceptually closer as the oxygenation level becomes higher whereas in the latter the pitch differences are perceptually equivalent across the whole range of values. The results show that anaesthetist participants produce significantly more accurate judgements of both absolute oxygenation values and size of oxygenation level difference when a logarithmic, rather than a linear, scale is used. The line of best fit for the logarithmic function was also closer to x = y than for the linear function. The results of these studies can inform the development and standardisation of pulse oximetry tones in order to improve patient safety.
Collapse
Affiliation(s)
- Zoe Brown
- Department of Pediatric Anesthesia, BC Children's Hospital, Vancouver, BC, Canada; Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver, BC, Canada
| | - Judy Edworthy
- Cognition Institute, University of Plymouth, Drake Circus, Plymouth, Devon PL4 8AA, UK.
| | - J Robert Sneyd
- Plymouth University Penninsula School of Medicine and Dentistry, The John Bull Building, Plymouth Science Park, Plymouth, Devon PL6 8BU, UK
| | - Joseph Schlesinger
- Department of Anesthesiology, Vanderbilt University Medical Centre, Nashville, TN, USA
| |
Collapse
|
17
|
|
18
|
The Sound Intensity and Characteristics of Variable-pitch Pulse Oximeters. J Clin Monit Comput 2008; 22:199-207. [DOI: 10.1007/s10877-008-9125-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2007] [Accepted: 04/23/2008] [Indexed: 10/22/2022]
|
19
|
Sanderson P. The multimodal world of medical monitoring displays. APPLIED ERGONOMICS 2006; 37:501-12. [PMID: 16759627 DOI: 10.1016/j.apergo.2006.04.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
A vision of the future of intraoperative monitoring for anesthesia is presented-a multimodal world based on advanced sensing capabilities. I explore progress towards this vision, outlining the general nature of the anesthetist's monitoring task and the dangers of attentional capture. Research in attention indicates different kinds of attentional control, such as endogenous and exogenous orienting, which are critical to how awareness of patient state is maintained, but which may work differently across different modalities. Four kinds of medical monitoring displays are surveyed: (1) integrated visual displays, (2) head-mounted displays, (3) advanced auditory displays and (4) auditory alarms. Achievements and challenges in each area are outlined. In future research, we should focus more clearly on identifying anesthetists' information needs and we should develop models of attention in different modalities and across different modalities that are more capable of guiding design.
Collapse
Affiliation(s)
- Penelope Sanderson
- ARC Key Centre for Human Factors, The University of Queensland, St Lucia, Qld 4072, Australia.
| |
Collapse
|