Vertullo CJ, Cadman J, Dabirrahmani D, Appleyard R. Can tape-screw fixation of a quadrupled semitendinosus graft in a full-length tibial tunnel provide superior fixation compared with a doubled semitendinosus-gracilis held with an interference screw? A matched-pair cadaveric biomechanical comparison.
J Orthop Traumatol 2018;
19:11. [PMID:
30128979 PMCID:
PMC6102157 DOI:
10.1186/s10195-018-0495-x]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Accepted: 01/24/2018] [Indexed: 01/11/2023] Open
Abstract
Background
In anterior cruciate ligament reconstruction, quadrupled semitendinosus (Quad ST) grafts have potential advantages over doubled semitendinosus–gracilis (ST/G) including larger diameter and gracilis preservation, however the ideal tibial fixation method of the resultant shorter Quad ST graft remains elusive if a fixed-loop suspensory fixation device is used on the femur. We investigated whether the tibial fixation biomechanical properties of a Quad ST fixed indirectly with polyethylene terephthalate tape tied over a screw in a full outside-in created tunnel was superior to a ST/G graft fixed with an interference screw.
Materials and methods
In a controlled laboratory study, six cadaveric matched pairs of each construct were subjected to cyclic loading to mimic physiologic loading during rehabilitation. This included preconditioning cycling, cyclic loading to 220 N for 500 cycles, then cyclic loading to 500 N for 500 cycles.
Results
High standard deviations across the measured parameters occurred with no significant difference between measured parameters of elongation for the different constructs. Elongation of the Quad-ST construct was greater at 10 and 100 cycles, but not statistically different. Four of the six Quad-ST constructs failed below 100 cycles, compared with two failures below 100 cycles in the ST/G construct. There was a strong correlation between cycles to failure and bone mineral density for the Quad ST-tape constructs.
Conclusions
Tibial fixation of Quad ST with a tied tape–screw construct in a full-length tunnel was not biomechanically superior to ST/G graft fixed with an interference screw, exhibited greater nonsignificant construct elongation with earlier failure, and was more reliant on bone mineral density.
Level of evidence
In vitro laboratory study.