1
|
González-González AM, Cruz R, Rosales-Ibáñez R, Hernández-Sánchez F, Carrillo-Escalante HJ, Rodríguez-Martínez JJ, Velasquillo C, Talamás-Lara D, Ludert JE. In Vitro and In Vivo Evaluation of a Polycaprolactone (PCL)/Polylactic-Co-Glycolic Acid (PLGA) (80:20) Scaffold for Improved Treatment of Chondral (Cartilage) Injuries. Polymers (Basel) 2023; 15:polym15102324. [PMID: 37242899 DOI: 10.3390/polym15102324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 05/09/2023] [Accepted: 05/10/2023] [Indexed: 05/28/2023] Open
Abstract
Articular cartilage is a specialized tissue that provides a smooth surface for joint movement and load transmission. Unfortunately, it has limited regenerative capacity. Tissue engineering, combining different cell types, scaffolds, growth factors, and physical stimulation has become an alternative for repairing and regenerating articular cartilage. Dental Follicle Mesenchymal Stem Cells (DFMSCs) are attractive candidates for cartilage tissue engineering because of their ability to differentiate into chondrocytes, on the other hand, the polymers blend like Polycaprolactone (PCL) and Poly Lactic-co-Glycolic Acid (PLGA) have shown promise given their mechanical properties and biocompatibility. In this work, the physicochemical properties of polymer blends were evaluated by Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscope (SEM) and were positive for both techniques. The DFMSCs demonstrated stemness by flow cytometry. The scaffold showed to be a non-toxic effect when we evaluated it with Alamar blue, and the samples were analyzed using SEM and phalloidin staining to evaluate cell adhesion to the scaffold. The synthesis of glycosaminoglycans was positive on the construct in vitro. Finally, the PCL/PLGA scaffold showed a better repair capacity than two commercial compounds, when tested in a chondral defect rat model. These results suggest that the PCL/PLGA (80:20) scaffold may be suitable for applications in the tissue engineering of articular hyaline cartilage.
Collapse
Affiliation(s)
- Arely M González-González
- Department of Infectomics and Molecular Pathogenesis, Center for Research and Advanced Studies (CINVESTAV), Mexico City 07360, Mexico
- Laboratorio de Ingeniería Tisular y Medicina Traslacional, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de Mexico (UNAM), Mexico City 54090, Mexico
| | - Raymundo Cruz
- Department of Infectomics and Molecular Pathogenesis, Center for Research and Advanced Studies (CINVESTAV), Mexico City 07360, Mexico
| | - Raúl Rosales-Ibáñez
- Laboratorio de Ingeniería Tisular y Medicina Traslacional, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de Mexico (UNAM), Mexico City 54090, Mexico
| | | | | | - Jesús Jiovanni Rodríguez-Martínez
- Laboratorio de Ingeniería Tisular y Medicina Traslacional, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de Mexico (UNAM), Mexico City 54090, Mexico
| | - Cristina Velasquillo
- Unidad de Ingeniería de Tejidos, Terapia Celular y Medicina Regenerativa, Instituto Nacional de Rehabilitación "Luis Guillermo Ibarra Ibarra", Ciudad de Mexico 14389, Mexico
| | - Daniel Talamás-Lara
- Department of Infectomics and Molecular Pathogenesis, Center for Research and Advanced Studies (CINVESTAV), Mexico City 07360, Mexico
| | - Juan E Ludert
- Department of Infectomics and Molecular Pathogenesis, Center for Research and Advanced Studies (CINVESTAV), Mexico City 07360, Mexico
| |
Collapse
|
2
|
Solvent selection and its effect on crystallization behavior of poly(ε-caprolactone) in electrospun poly(ε-caprolactone)/poly (lactic-co-glycolic acid) blend fibers. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.128896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
3
|
Yang M, Zhang Y, Fang C, Song L, Wang Y, Lu L, Yang R, Bu Z, Liang X, Zhang K, Fu Q. Urine-Microenvironment-Initiated Composite Hydrogel Patch Reconfiguration Propels Scarless Memory Repair and Reinvigoration of the Urethra. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2109522. [PMID: 35120266 DOI: 10.1002/adma.202109522] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 02/02/2022] [Indexed: 06/14/2023]
Abstract
The harsh urine microenvironment (UME), as an inherent hurdle, endangers and renders urethral repair unreachable. Innovatively, the unfavorable UME is utilized as the design source to construct a UME-responsive 3D-printed hydrogel patch for realizing scarless memory repair, wherein laser-excited reactive oxygen species (ROS) production and mechanical strength elevation using chemically crosslinked silicon quantum dots are accessible. Intriguingly, the proposed composite scaffolds can respond to Ca2+ in urine, cause structure reconfiguration, and repress swelling to further enhance scaffold stiffness. Systematic experiments validate that ROS birth and unexpected stiffness elevation in such UME-responsive scaffolds can realize scarless memory repair of the urethra in vivo. Comprehensive mechanism explorations uncover that the activations of cell proliferation and collagen-related genes (e.g., MMP-1 and COL3A1) and the dampening of fibrosis-related (e.g., TGF-β/Smad) and mechanosensitive genes (e.g., YAP/TAZ) are responsible for the scarless memory repair of such UME-responsive scaffolds via enhancing collagen deposition, recalling mechanical memory, decreasing fibrosis and inflammation, and accelerating angiogenesis. The design rationales (e.g., UME-initiated structure reconfiguration and antiswelling) can serve as an instructive and general approach for urethra repair.
Collapse
Affiliation(s)
- Ming Yang
- Department of Urology, Affiliated Sixth People's Hospital, Shanghai Jiaotong University, No. 600 Yi-Shan Road, Shanghai, 200233, P. R. China
- Department of Medical Ultrasound and Central Laboratory, Nanotechnology and Intestinal Microecology Research Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, No. 301 Yan-chang-zhong Road, Shanghai, 200072, P. R. China
- Department of Plastic and Reconstructive Surgery, Shanghai Key Laboratory of Tissue Engineering, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Yang Zhang
- Department of Medical Ultrasound and Central Laboratory, Nanotechnology and Intestinal Microecology Research Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, No. 301 Yan-chang-zhong Road, Shanghai, 200072, P. R. China
| | - Chao Fang
- Department of Medical Ultrasound and Central Laboratory, Nanotechnology and Intestinal Microecology Research Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, No. 301 Yan-chang-zhong Road, Shanghai, 200072, P. R. China
| | - Li Song
- Department of Medical Ultrasound and Central Laboratory, Nanotechnology and Intestinal Microecology Research Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, No. 301 Yan-chang-zhong Road, Shanghai, 200072, P. R. China
| | - Ying Wang
- Department of Urology, Affiliated Sixth People's Hospital, Shanghai Jiaotong University, No. 600 Yi-Shan Road, Shanghai, 200233, P. R. China
| | - Lu Lu
- Department of Medical Ultrasound and Central Laboratory, Nanotechnology and Intestinal Microecology Research Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, No. 301 Yan-chang-zhong Road, Shanghai, 200072, P. R. China
| | - Ranxing Yang
- Department of Urology, Affiliated Sixth People's Hospital, Shanghai Jiaotong University, No. 600 Yi-Shan Road, Shanghai, 200233, P. R. China
| | - Zhaoting Bu
- Department of Medical Ultrasound and Central Laboratory, Nanotechnology and Intestinal Microecology Research Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, No. 301 Yan-chang-zhong Road, Shanghai, 200072, P. R. China
| | - Xiayi Liang
- Department of Medical Ultrasound and Central Laboratory, Nanotechnology and Intestinal Microecology Research Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, No. 301 Yan-chang-zhong Road, Shanghai, 200072, P. R. China
| | - Kun Zhang
- Department of Medical Ultrasound and Central Laboratory, Nanotechnology and Intestinal Microecology Research Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, No. 301 Yan-chang-zhong Road, Shanghai, 200072, P. R. China
| | - Qiang Fu
- Department of Urology, Affiliated Sixth People's Hospital, Shanghai Jiaotong University, No. 600 Yi-Shan Road, Shanghai, 200233, P. R. China
| |
Collapse
|
4
|
Rosales-Ibáñez R, Viera-Ruiz AE, Cauich-Rodríguez JV, Carrillo-Escalante HJ, González-González A, Rodríguez-Martínez JJ, Hernández-Sánchez F. Electrospun/3D-printed PCL bioactive scaffold for bone regeneration. Polym Bull (Berl) 2022. [DOI: 10.1007/s00289-022-04149-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
5
|
Ławkowska K, Rosenbaum C, Petrasz P, Kluth L, Koper K, Drewa T, Pokrywczynska M, Adamowicz J. Tissue engineering in reconstructive urology-The current status and critical insights to set future directions-critical review. Front Bioeng Biotechnol 2022; 10:1040987. [PMID: 36950181 PMCID: PMC10026841 DOI: 10.3389/fbioe.2022.1040987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Accepted: 12/13/2022] [Indexed: 03/05/2023] Open
Abstract
Advanced techniques of reconstructive urology are gradually reaching their limits in terms of their ability to restore urinary tract function and patients' quality of life. A tissue engineering-based approach to urinary tract reconstruction, utilizing cells and biomaterials, offers an opportunity to overcome current limitations. Although tissue engineering studies have been heralding the imminent introduction of this method into clinics for over a decade, tissue engineering is only marginally applied. In this review, we discuss the role of tissue engineering in reconstructive urology and try to answer the question of why such a promising technology has not proven its clinical usability so far.
Collapse
Affiliation(s)
- Karolina Ławkowska
- Department of Regenerative Medicine, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
- *Correspondence: Karolina Ławkowska, ; Clemens Rosenbaum, ; Piotr Petrasz, ; Krzysztof Koper, ; Luis Kluth, ; Tomasz Drewa, ; Marta Pokrywczynska, ; Jan Adamowicz,
| | - Clemens Rosenbaum
- Department of Urology Asklepios Klinik Barmbek Germany, Urologist in Hamburg, Hamburg, Germany
- *Correspondence: Karolina Ławkowska, ; Clemens Rosenbaum, ; Piotr Petrasz, ; Krzysztof Koper, ; Luis Kluth, ; Tomasz Drewa, ; Marta Pokrywczynska, ; Jan Adamowicz,
| | - Piotr Petrasz
- Department of Urology Voivodeship Hospital Gorzów Wielkopolski, Gorzów Wielkopolski, Poland
- *Correspondence: Karolina Ławkowska, ; Clemens Rosenbaum, ; Piotr Petrasz, ; Krzysztof Koper, ; Luis Kluth, ; Tomasz Drewa, ; Marta Pokrywczynska, ; Jan Adamowicz,
| | - Luis Kluth
- Department of Urology, University Medical Center Frankfurt, Frankfurt am Main, Germany
- *Correspondence: Karolina Ławkowska, ; Clemens Rosenbaum, ; Piotr Petrasz, ; Krzysztof Koper, ; Luis Kluth, ; Tomasz Drewa, ; Marta Pokrywczynska, ; Jan Adamowicz,
| | - Krzysztof Koper
- Department of Clinical Oncology and Nursing, Collegium Medicum, Nicolaus Copernicus University, Curie-Skłodowskiej 9, Bydgoszcz, Poland
- *Correspondence: Karolina Ławkowska, ; Clemens Rosenbaum, ; Piotr Petrasz, ; Krzysztof Koper, ; Luis Kluth, ; Tomasz Drewa, ; Marta Pokrywczynska, ; Jan Adamowicz,
| | - Tomasz Drewa
- Department of Regenerative Medicine, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
- *Correspondence: Karolina Ławkowska, ; Clemens Rosenbaum, ; Piotr Petrasz, ; Krzysztof Koper, ; Luis Kluth, ; Tomasz Drewa, ; Marta Pokrywczynska, ; Jan Adamowicz,
| | - Marta Pokrywczynska
- Department of Regenerative Medicine, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
- *Correspondence: Karolina Ławkowska, ; Clemens Rosenbaum, ; Piotr Petrasz, ; Krzysztof Koper, ; Luis Kluth, ; Tomasz Drewa, ; Marta Pokrywczynska, ; Jan Adamowicz,
| | - Jan Adamowicz
- Department of Regenerative Medicine, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
- *Correspondence: Karolina Ławkowska, ; Clemens Rosenbaum, ; Piotr Petrasz, ; Krzysztof Koper, ; Luis Kluth, ; Tomasz Drewa, ; Marta Pokrywczynska, ; Jan Adamowicz,
| | | |
Collapse
|
6
|
Biazar E, Kamalvand M, Avani F. Recent advances in surface modification of biopolymeric nanofibrous scaffolds. INT J POLYM MATER PO 2021. [DOI: 10.1080/00914037.2020.1857383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Esmaeil Biazar
- Department of Biomaterials Engineering, Tonekabon Branch, Islamic Azad University, Tonekabon, Iran
| | - Mahshad Kamalvand
- Department of Biomaterials Engineering, Tonekabon Branch, Islamic Azad University, Tonekabon, Iran
| | - Farzaneh Avani
- Biomedical Engineering Faculty, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| |
Collapse
|
7
|
Martín-Pat GE, Rodriguez-Fuentes N, Cervantes-Uc JM, Rosales-Ibáñez R, Carrillo-Escalante HJ, Ku-Gonzalez AF, Avila-Ortega A, Hernandez-Sanchez F. Effect of different exposure times on physicochemical, mechanical and biological properties of PGS scaffolds treated with plasma of iodine-doped polypyrrole. J Biomater Appl 2020; 35:485-499. [DOI: 10.1177/0885328220941466] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Polyglycerol sebacate (PGS) scaffolds obtained using a leaching technique were modified with iodine-doped polypyrrole (PPy-I) in a plasma reactor in order to study the effect of exposure time on the cell viability of hDPSCs. SEM analysis showed the formation and growth of PPy-I particles as the exposure time was increased, while FTIR and XPS analysis revealed the presence of -NH- and N+ groups in the chemical composition of the surfaces, relating to the increase in the amount of PPY-I particles. The water contact angle measurements showed an increase in the scaffold’s hydrophilicity with greater exposure times which was also attributed to the rising of PPy-I particles. It was also observed that PPy-I promotes the rigidity of the treated PGS scaffolds. when in direct contact with treated PGS scaffolds, cell viability improved with respect to non-treated scaffolds, however only at shorter time exposures. Extracts of plasma-treated PGS scaffolds showed high cytotoxicity as the time exposure to plasma treatment was increased.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Alejandro Avila-Ortega
- Facultad de Estudios Superiores Iztacala, Universidad Nacional Autonoma de Mexico, Ciudad de Mexico, Mexico
| | | |
Collapse
|