1
|
Effect of time and temperature-dependent changes of IOL material properties on IOL: Lens capsule interactions. Exp Eye Res 2021; 211:108726. [PMID: 34403680 DOI: 10.1016/j.exer.2021.108726] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 08/05/2021] [Accepted: 08/09/2021] [Indexed: 11/15/2022]
Abstract
Posterior Capsule Opacification (PCO) is the most common complication associated with Intraocular Lens (IOL) implantation. Based on the assumption that the interactions between an IOL and the lens capsule (LC) may influence the extent of PCO formation, a new in vitro model was developed to quantify the adhesion force of an IOL to simulated LC using a custom-designed micro-force tester. Using this system, we examined the influence of temperature (room temperature vs. body temperature) and incubation time (0 vs. 24 h) on the adhesion force between IOLs and LCs. The results show that, in line with clinical observations of PCO incidence, the adhesion force increased at body temperature and with increase in incubation time in the following order, Acrylic foldable IOLs > Silicone IOLs > PMMA IOLs. By examining the changes of surface properties as a function of temperature and incubation time, we found that acrylic foldable IOLs showed the largest increase in their hydrophilicity and reported the lowest surface roughness in comparison to other IOL groups. Coincidentally, using a newly established macromolecular dye imaging system to simulate cell migration between IOLs and LC, we observed that the amount of macromolecular dye infiltration between IOLs and LCs was in the following order: PMMA IOLs > Silicone IOLs > Acrylic foldable IOLs. These results support a new potential mechanism that body temperature, incubation time, surface hydrophilicity and smoothness of IOLs greatly contribute to their tight binding to LCs and such tight binding may lead to reduced IOL: LC space, cell infiltration, and thus PCO formation.
Collapse
|
2
|
Microscopic Characteristics of Late Intraocular Lens Opacifications. Arch Pathol Lab Med 2021; 145:759-767. [PMID: 33091924 DOI: 10.5858/arpa.2019-0626-ra] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/09/2020] [Indexed: 11/06/2022]
Abstract
CONTEXT.— The increases in overall life expectancy and in lens surgeries performed on younger patients have resulted in a significant increase in the anticipated duration of artificial intraocular lenses (IOLs) in the eye. Thus, the physicochemical properties of the IOL become a critical issue, and several types of postoperative IOL opacifications have been reported. OBJECTIVE.— To describe the microscopic characteristics of opacified IOLs. Glistenings and subsurface nanoglistenings are fluid-related phenomena developing mainly in hydrophobic acrylic IOLs and are associated with aqueous influx into the IOL matrix. Calcification presents in hydrophilic acrylic or silicone IOLs as deposits of hydroxyapatite or other phases of calcium. Snowflake degeneration is less common, and it manifests in older polymethyl methacrylate IOLs. DATA SOURCES.— PubMed and ScienceDirect databases were searched for the following keywords: intraocular lens, IOL, cataract surgery, phacoemulsification, opacification, glistening, subsurface nanoglistenings, calcification, snowflake degeneration. English-language articles published up to October 15, 2019 were included in the study. The manuscript contains mainly a literature review; however, it was supplemented with original investigations from the David J. Apple International Laboratory for Ocular Pathology. CONCLUSIONS.— Glistenings and subsurface nanoglistenings should be evaluated in a hydrated state and at room temperature; they manifest as microvacuoles sized from 1.0 to greater than 25.0 μm and less than 200 nm, respectively. Calcification deposits are situated on or underneath the surface of the IOL and can be stained with a 1% alizarin red solution or with the von Kossa method. Snowflake degeneration manifests as "particles" or "crystals," causing whitish IOL discoloration. Scanning electron microscopy or energy dispersive X-ray spectroscopy may improve the diagnostic accuracy.
Collapse
|
3
|
Abstract
PURPOSE OF REVIEW Phacoemulsification cataract surgery is one of the most commonly performed surgical procedure worldwide. In the majority of cases, intraocular lenses (IOLs) are implanted. Due to the increasing life expectancy and the fact that cataract surgery is performed in earlier stages, the anticipated IOL duration in the eye has increased over the last decades. The aim of this study was to review the types and describe the characteristics of late intraocular lens opacifications. RECENT FINDINGS Calcification was the most commonly reported type of opacification in hydrophilic IOLs; it usually negatively impacted the visual function and required IOL explantation. Glistening manifested in hydrophobic acrylic lenses and was frequent in some IOL models. In most cases glistening and subsurface nanoglistenigs do not lead to a decline in visual acuity or require IOL exchange. Current studies indicate that fluid-related phenomena may induce straylight, leading to a decrease of comfort and quality of vision. SUMMARY Several reports on late IOL opacifications have been published in recent years. In some cases, particularly in glistening, the development of the opacifications might be related to IOL aging. The influence of the fluid-related microvacuoles on the quality of vision requires further research.
Collapse
|
4
|
An evaluation of glistening and stability of intraocular lens material manufactured by different methods. Eur J Ophthalmol 2020; 31:427-435. [PMID: 32000525 DOI: 10.1177/1120672120902038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate glistening and long-term stability of five commercially available intraocular lenses. METHODS This experimental study evaluated the SN60WF (Alcon), XY1 (Hoya), NS-60YG (NIDEK), ZCB00V (Johnson & Johnson Vision) and AN6KA (Kowa) intraocular lenses. To generate glistenings, intraocular lenses were immersed in physiological saline at 50°C for 2 h, then left in situ at 35°C and removed at regular intervals over 24 h. Stability of the intraocular lens material was assessed by immersing intraocular lenses into vials of purified water placed at 100°C for 115 days, which simulated 20-year ageing. Gas chromatography-mass spectrometry was used to detect leached compounds. RESULTS Almost no glistenings were observed for the AN6KA. Glistenings were observed in the remaining intraocular lenses after 3 h. The number of glistenings gradually disappeared by 6 h for all intraocular lenses except SN60WF (12 h). Only the NS-60YG and ZCB00V intraocular lenses had no changes in weight or dimensions. Gas chromatography-mass spectrometry detected phenethyl alcohol in XY1 and SN60WF, 2-phenoxyethanol in AN6K and no compounds in the remaining intraocular lenses. A peak shift due to the carbonyl group between 1600 and 1700 cm-1 was detected for the SN60WF and AN6K intraocular lenses only. CONCLUSION SN60WF had the most numerous glistenings that resolved over a longer duration. The long-term stability test confirmed elution of the intraocular lens material-derived compounds and signs of degradation for the XY1, SN60WF and AN6K intraocular lenses. NS-60YG and ZCB00V showed no signs of deterioration due to ageing. Differing manufacturing methods likely play a role in the stability of intraocular lenses.
Collapse
|
5
|
Experimental study of the mechanisms leading to the formation of glistenings in intraocular lenses by Raman spectroscopy. BIOMEDICAL OPTICS EXPRESS 2019; 10:1870-1881. [PMID: 31086709 PMCID: PMC6484980 DOI: 10.1364/boe.10.001870] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 02/21/2019] [Accepted: 02/23/2019] [Indexed: 06/09/2023]
Abstract
The phenomenon of glistenings, often appearing in intraocular lenses (IOLs) of patients after some time from the surgical operation, is potentially able to induce a poor quality of vision and, therefore, frustrate IOL implantation itself. In this paper, we combine optical microscopy with micro-Raman spectroscopy to get a deeper insight on the mechanism ruling, at microscopic scale, glistening formation. In particular, we have analyzed two types of IOLs, characterized by a different internal hydrophobicity but a similar polymer hydration coefficient. Raman imaging of single microvacuoles reveals that water creeps into the polymeric network, which traps water. Finally, applying the Principal Component Analysis (PCA) to Raman data, we provide information on the probable mechanism leading to water trapping in the two kinds of analyzed IOLs.
Collapse
|
6
|
Biomaterial Influence on Intraocular Lens Performance: An Overview. J Ophthalmol 2018; 2018:2687385. [PMID: 29736282 PMCID: PMC5874989 DOI: 10.1155/2018/2687385] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Revised: 12/08/2017] [Accepted: 01/02/2018] [Indexed: 11/18/2022] Open
Abstract
There is strong evidence that the IOL material is the factor having the greatest impact on posterior capsule opacification (PCO), anterior capsule opacification (ACO) development, and glistening formation after cataract surgery, even though there are other IOL features—such as haptic material and design and edge and optic design—that also have some influence. We reviewed the published literature describing the adverse events that are mainly related to the intraocular lens (IOL) material, such as PCO, ACO, and the subsequent capsule contraction, as well as glistening formation. The adverse events presented in this overview are the most common ones in clinical practice, and therefore, they are generally included in the clinical protocols for IOL evaluation.
Collapse
|
7
|
Steam-like clouding observed on anterior surface of intraocular lens developed soon after implantation. Am J Ophthalmol Case Rep 2018; 11:172-175. [PMID: 30128370 PMCID: PMC6097176 DOI: 10.1016/j.ajoc.2018.01.049] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Accepted: 01/29/2018] [Indexed: 11/28/2022] Open
Abstract
Purpose To report our findings in three cases of a clouding of the anterior surface of an implanted intraocular lens that developed within 14 days after implantation. Observations Three eyes were implanted with the same model IOL and a steam-like clouding developed on the anterior surface of the IOL. The clouding occurred on days 4, 7, and 14 after the implantation in an area of the IOL that was in contact with the aqueous humor. The clouding was accompanied by a reduction of vision in all cases but without any other abnormalities such as inflammation. The clouding was resolved by irrigation and aspiration of the anterior chamber in 2 cases at 2 and 34 days after the onset, and a spontaneous disappearance in 1 case at 14 days after the onset of the clouding. After the disappearance of the clouding, the visual acuity improved, and there were no recurrences. The solution used to irrigate the anterior chamber was collected and examined to confirm the absence of cellular materials. Elemental analyses confirmed that sodium and chloride were the predominant ions. The IOL implanted was the XACT lens (Advanced Vision Science, USA) which is a hydrophobic acrylic IOL and is characterized by having higher water content compared to other IOLs. In addition, it is packaged in 0.9% saline to maintain the pre-hydrated condition. These aspects may be related to the cause of the clouding. This IOL was implanted in 3271 eyes in our clinic, and 3 of them (0.09%) developed this clouding. Conclusions and importance We report our findings in 3 eyes that developed a clouding on the anterior surface of the lens soon after implantation. The clouding was localized to the area in contact with the aqueous. The cause of the clouding was not determined.
Collapse
|
8
|
Glistenings, anterior/posterior capsular opacification and incidence of Nd:YAG laser treatments with two aspheric hydrophobic acrylic intraocular lenses - a long-term intra-individual study. Acta Ophthalmol 2017; 95:671-677. [PMID: 28371401 DOI: 10.1111/aos.13444] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Accepted: 02/20/2017] [Indexed: 11/29/2022]
Abstract
PURPOSE To compare two hydrophobic acrylic intraocular lenses (IOLs) regarding long-term anterior/posterior capsular opacification (ACO/PCO) development and need for neodymium:Yttrium-Aluminum-Garnet (Nd:YAG) laser treatment due to visually disturbing PCO, and to study development of glistenings in the IOL materials. METHODS In a prospective, randomized, intra-individual, comparative trial, 50 cataract patients received either an AcrySof IQ® SN60WF (Alcon, Fort Worth, TX, USA) or a Tecnis® ZCB00 (Abbott Medical Optics, Santa Ana, CA, USA) IOL in the first operated eye, and the second eye received the IOL type not implanted in the first eye. Anterior/posterior capsular opacification (ACO/PCO) and fibrosis were monitored with slit-lamp photography and semi-automated digital analysis 2 and 3 years postoperatively. Glistenings were semi-quantitatively assessed in slit-lamp photographs. Nd:YAG laser treatment for visually disturbing PCO was monitored. RESULTS Visual outcomes were similar for the two IOLs. Anterior capsular fibrosis and/or opacification developed more often in SN60WF eyes. Mean PCO area percentage was larger in ZCB00 eyes 3 years after surgery, but severity score did not differ with statistical significance between the two IOLs. Six ZCB00 eyes and 2 SN60WF eyes underwent Nd:YAG laser treatment during a mean of 4 years 8 months after surgery. This difference was not statistically significant. A high amount of glistenings developed in most SN60WF IOLs, while only few ZCB00 IOLs displayed a low degree of glistenings. CONCLUSION Visual outcomes, PCO development over time and need for Nd:YAG laser treatment were similar for the two IOLs. Anterior capsule fibrosis/contraction and glistenings were more pronounced with the SN60WF IOL.
Collapse
|
9
|
Glistening in glaucomatous eyes: visual performances and risk factors. Acta Ophthalmol 2014; 92:529-34. [PMID: 24119141 DOI: 10.1111/aos.12276] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Accepted: 08/22/2013] [Indexed: 11/27/2022]
Abstract
PURPOSE To analyse risk factors and visual performances of glaucomatous eyes with glistening in the intra-ocular lens (IOL). METHODS Prospective study performed between November 2010 and April 2011 and involving 67 consecutive glaucomatous eyes (47 patients), who previously had a phacoemulsification with a hydrophobic acrylic IOL implanted in the capsular bag. Glistening was classified in three groups of severity grade: G0 (<50 microvacuoles per mm(2) ), G1 (50-150 microvacuoles per mm(2) ), and G2 (>150 microvacuoles per mm(2) ). All eyes underwent a best-corrected visual acuity evaluation (BCVA, LogMAR scale), a complete clinical examination, a visual field test, a contrast sensitivity evaluation and a wavefront analysis of high-order aberrations (HOAs) using a Shack-Hartmann aberrometer. Eyes with a posterior capsular opacification and a BCVA>0.30 LogMAR were excluded. RESULTS Twenty six eyes (38.8%) had a grade 0, 12 eyes (17.9%) a grade 1 and 29 eyes (43.3%) a grade 2 of glistening severity grade. The mean follow-up after cataract surgery was 35.2 ± 24.2 months and was significantly higher for G1 and G2 groups (p < 0.001). A higher number of topical glaucoma medication were associated with a higher glistening severity grade (p < 0.05). G1 and G2 groups had significantly lower mean contrast sensitivity values at high spatial frequencies and significantly higher loss variance (LV) values of the visual field test (p < 0.05). There was no significant difference in mean BCVA between groups (p = 0.455). CONCLUSIONS In glaucomatous eyes, glistening increased with time was associated with the number of topical glaucoma medications daily instilled and altered visual performances. It should be a consideration for glaucoma patients who are more likely to develop glistening within the IOL optic.
Collapse
|
10
|
Abstract
A new, single-piece, hydrophobic acrylic lens – the first constructed with a lens optic and haptics comprised of a hydroxyethyl methacrylate-polyethylene glycol phenyl ether acrylate–styrene copolymer, cross-linked with ethylene glycol dimethacrylate, and labeled as “glistening-free” – was recently introduced globally. Glistenings have been a significant source of clinical concern with previous hydrophobic lens designs. This new monofocal lens provides enhanced, clear optics for lens-based surgery. The superior optical clarity of this lens is achieved through the elimination of glistenings, enhanced surface durability, high refractive index, a high Abbe number, and an aspheric design. Additionally, the lens design reduces the risk of developing posterior capsule opacification.
Collapse
|
11
|
Incidence of glistenings with the latest generation of yellow-tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 2012; 38:1140-6. [PMID: 22727284 DOI: 10.1016/j.jcrs.2012.01.031] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2011] [Revised: 01/30/2012] [Accepted: 01/31/2012] [Indexed: 10/28/2022]
Abstract
PURPOSE To evaluate the incidence of glistenings in a large series of consecutive eyes with a blue light-filtering hydrophobic acrylic intraocular lens (IOL) and the relationship with parameters such as age, sex, follow-up length, and corrected distance visual acuity (CDVA). SETTING Service d'Ophtalmologie, Centre Hospitalier et Universitaire Bordeaux, Bordeaux, France. DESIGN Cross-sectional study. METHODS This study included 111 eyes of 74 patients (age range 33 to 86 years). All cases had cataract surgery with Acrysof SN60WF monofocal IOL implantation and had a routine postoperative examination between March 2011 and June 2011. The incidence and severity of glistenings were evaluated with the slitlamp. Also evaluated was their relationship with age, sex, follow-up length, IOL power, and CDVA. Glistenings were subjectively graded (0 = absent; 1 = moderate; 2 = dense). RESULTS Glistenings occurred in 96 eyes (86.5%). Glistenings were of grade 1 severity in 45 eyes (40.5%) and of grade 2 severity in 51 eyes (45.9%). The follow-up was significantly longer in eyes with grade 2 glistenings (P ≤ .01). A limited, but significant, correlation was found between glistening severity and length of follow-up (r = 0.32, P<.01). Although there was a trend toward decreased visual acuities at higher glistening grades (r = 0.22, P = .01), there were no significant differences in CDVA between the glistening severity groups (P = .14). CONCLUSIONS Glistenings were common in eyes with the blue light-filtering hydrophobic acrylic IOL and increased over time. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
|
12
|
Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function. Am J Ophthalmol 2012; 154:240-251.e2. [PMID: 22633349 DOI: 10.1016/j.ajo.2012.03.011] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Revised: 03/08/2012] [Accepted: 03/08/2012] [Indexed: 10/28/2022]
Abstract
PURPOSE To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. DESIGN Case-control study. METHODS Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. RESULTS Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. CONCLUSIONS At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations.
Collapse
|
13
|
Calcification and Membrane Formation on the Surface of Intraocular Lenses in a Rabbit Model. Curr Eye Res 2012; 37:471-8. [DOI: 10.3109/02713683.2011.648254] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
14
|
Glistenings and surface light scattering in intraocular lenses. J Cataract Refract Surg 2010; 36:1398-420. [DOI: 10.1016/j.jcrs.2010.06.003] [Citation(s) in RCA: 138] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2009] [Revised: 04/27/2010] [Accepted: 04/29/2010] [Indexed: 11/28/2022]
|
15
|
Abstract
PURPOSE To evaluate the safety and efficacy of a hydrophilic acrylic intraocular lens (B-Lens((R)), Hanita, Israel) during a 2-year follow-up period. SETTING Department of Ophthalmology, Meir Hospital, Sapir Medical Center, Kfar-Saba, Israel. PATIENTS & METHODS Slit lamp biomicroscopy, refraction, visual function and patient satisfaction were recorded in 147 patients at 1 week, and at 1, 3, 12, and 24 months after surgery. RESULTS Nine cases (6%) were associated with partial rupture of the superior haptic intraoperatively, which did not preclude in-the-bag centration of the IOL in all cases. Postoperative complications were mild or reversible and rarely observed. The posterior capsule opacification (PCO) rate increased considerably (from 0.35 to 0.80) from 1 to 2 years but was for the most clinically insignificant; 16 of the 90 cases (18%) with PCO at 2 years had clinically significant opacification of the posterior capsule. No IOL discoloration was observed. BCVA stabilized by the third month and refraction was at the predicted level at two years. Eighty-one of 91 cases (89%) had BCVA equal to or more than 20/40 and 43 of 91 (47%) gained a BCVA of 20/20 at two years. CONCLUSION Hydrophilic acrylic B-Lens((R)) implantation is safe and effective for patients with cataract.
Collapse
|
16
|
Glistenings in a large series of hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 2009; 35:2121-6. [DOI: 10.1016/j.jcrs.2009.06.029] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2009] [Revised: 06/12/2009] [Accepted: 06/16/2009] [Indexed: 10/20/2022]
|