1
|
Lingegowda D, Gupta B, Gehani A, Sen S, Ghosh P. Catheter Lock Anchor Technique for Placement of Retrogradely Tunneled Implantable Ports. JOURNAL OF CLINICAL INTERVENTIONAL RADIOLOGY ISVIR 2022. [DOI: 10.1055/s-0042-1751034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
Abstract
Objective Groshong valved catheters require retrograde tunneling and a port chamber needs to be attached to the catheter after trimming. During this process, working space constraints are generally faced by operators. We describe a novel technique to improve the comfort of the operator while working in a constrained space.
Materials and Method The port catheter with the distal valve is retrogradely tunneled and trimmed. Thread from absorbable surgical suture is used to anchor the catheter lock. Anchored catheter lock is comfortably pushed over the catheter into the subcutaneous tunnel without it being migrated proximally. Once the port chamber is attached to the catheter, the catheter lock is retrieved back and moved to the locking position. We retrospectively analyzed implantable ports for smoothness of curves and outcomes in terms of catheter days.
Results Technical success was achieved in all patients. There were no periprocedural complications. Clinical success was achieved in 27/29 cases. Early port removal was done due to infection in one patient and for nonhealing of the wound in one patient.
Conclusion The catheter lock anchor is a safe and useful technique for the placement of valved ports. A satisfactory catheter-nut angle can be achieved with this technique.
Collapse
Affiliation(s)
| | - Bharat Gupta
- Department of Radiology, Tata Medical Center, Kolkata, West Bengal, India
| | - Anisha Gehani
- Department of Radiology, Tata Medical Center, Kolkata, West Bengal, India
| | - Saugata Sen
- Department of Radiology, Tata Medical Center, Kolkata, West Bengal, India
| | - Priya Ghosh
- Department of Radiology, Tata Medical Center, Kolkata, West Bengal, India
| |
Collapse
|
2
|
Chou PL, Fu JY, Cheng CH, Chu Y, Wu CF, Ko PJ, Liu YH, Wu CY. Current port maintenance strategies are insufficient: View based on actual presentations of implanted ports. Medicine (Baltimore) 2019; 98:e17757. [PMID: 31689833 PMCID: PMC6946320 DOI: 10.1097/md.0000000000017757] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 09/26/2019] [Accepted: 10/02/2019] [Indexed: 12/28/2022] Open
Abstract
Nursing staff play a crucial role in maintaining a functional port. Nursing guidelines recommend standard maintenance with 10 ml irrigation without consideration for variations among patients and individual nursing staff. The aim of this study is to identify the efficacy of the current maintenance strategy and analyze the correlation between complications and actual port presentations, based on disassembled intravenous ports after removal from patients. We attempt to organize the information and propose a definite maintenance strategy.After treatment completion, or due to complications, 434 implanted intravenous ports were removed from patients. All ports were deconstructed to observe their actual presentations and were then analyzed in conjunction with medical records. The correlation between complications and actual presentations was analyzed.From March 2012 to December 2017, 434 implanted intravenous ports were removed from oncology patients after completion of treatment or catheter related complications. From the view of maintenance related presentations, injection chamber blood clot was highly correlated with chemotherapy completion (P < .001) and malfunction (P = .005), while tip blood clot (P = .043) was related with chemotherapy completion and catheter fibrin (P = .015) was related to malfunction. From the view of structure related presentations, broken catheter integrity was correlated to chemotherapy completion (P = .007), fracture (P < .001), and malfunction (P = .008). Compression groove was related to chemotherapy completion (P = .03) and broken catheter at protruding stud was related to fracture (P = .04), while diaphragm rupture was correlated to chemotherapy completion (P = .048) and malfunction. (P < .001).Current port maintenance is insufficient for ideal port maintenance, whereby maintenance-related presentations, including tip clot, catheter fibrin, and injection chamber blood clot were identified. We propose a recommended maintenance strategy based on our findings. Structure-related presentations, including broken catheter integrity, broken catheter at protruding stud and diaphragm rupture were seen in patients with longer implantation period. Removal of the implanted port may be considered after 5 years if no disease relapse is noted.
Collapse
Affiliation(s)
- Pin-Li Chou
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Jui-Ying Fu
- Chang Gung University, Taiwan
- Division of Chest, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Chia-Hui Cheng
- Laboratory of Cardiovascular Physiology, Department of Medical Research and Development, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Yen Chu
- Chang Gung University, Taiwan
- Laboratory of Cardiovascular Physiology, Department of Medical Research and Development, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Ching-Feng Wu
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Po-Jen Ko
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Yun-Hen Liu
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Ching-Yang Wu
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| |
Collapse
|
3
|
Nishinari K, Wolosker N, Vinicius Bernardi C, Yazbek G. Totally Implantable Ports Connected to Valved Catheters for Chemotherapy: Experience from 350 Groshong Devices. J Vasc Access 2018; 11:17-22. [PMID: 20119917 DOI: 10.1177/112972981001100104] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Purpose There are few studies regarding the use of totally implantable valved ports for chemotherapy. The objective of this study was to analyze the results obtained from consecutive implantation of 350 devices. Methods Adult patients submitted to port insertion in veins of the superior vena cava system over a 17-month period (July 2006 to December 2007) were considered. The device used was composed of a titanium and silicone rubber port (Dome Portâ„¢; Bard Inc, Salt Lake City, UT) connected to an 8.0 Fr silastic Groshongâ„¢ catheter tube. Follow-up was conducted on outpatient data and during clinical readmissions, until the device was removed or the patient died. Results Three hundred and fifty devices, total of 74,691 days in situ, were inserted, with a median follow-up of 176 days. There were 11 early complications (3.1%) and 49 late complications (14%), 21 of these (6%) were considered major ones. Early complications comprised four instances of phlebitis of the external jugular, three of pocket infection, two of technical failure and two of ecchymosis. Late complications comprised 33 instances of withdrawal difficulty, 12 of port-related bacteremia, two of deep venous thrombosis, one of occlusion and one of catheter fracture. Out of the 350 catheters implanted, 258 (73.5%) were still being used, 73 (21%) remained in use until the patient died, five (1.5%) were removed at the end of the treatment and 14 (4%) were removed because of complications. Conclusions There was a low rate of major complications associated with this valved system justifying its use.
Collapse
Affiliation(s)
- Kenji Nishinari
- Department of Vascular Surgery, Hospital A.C. Camargo, São Paulo - Brazil
| | - Nelson Wolosker
- Department of Vascular Surgery, Hospital A.C. Camargo, São Paulo - Brazil
| | | | - Guilherme Yazbek
- Department of Vascular Surgery, Hospital A.C. Camargo, São Paulo - Brazil
| |
Collapse
|
4
|
Goossens GA, Stas M, Jérôme M, Moons P. Systematic review: malfunction of totally implantable venous access devices in cancer patients. Support Care Cancer 2011; 19:883-98. [DOI: 10.1007/s00520-011-1171-3] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2010] [Accepted: 04/18/2011] [Indexed: 11/25/2022]
|