1
|
Banchhor SK, Londhe ND, Araki T, Saba L, Radeva P, Khanna NN, Suri JS. Calcium detection, its quantification, and grayscale morphology-based risk stratification using machine learning in multimodality big data coronary and carotid scans: A review. Comput Biol Med 2018; 101:184-198. [DOI: 10.1016/j.compbiomed.2018.08.017] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 08/14/2018] [Accepted: 08/14/2018] [Indexed: 01/04/2023]
|
2
|
Ikeda N, Dey N, Sharma A, Gupta A, Bose S, Acharjee S, Shafique S, Cuadrado-Godia E, Araki T, Saba L, Laird JR, Nicolaides A, Suri JS. Automated segmental-IMT measurement in thin/thick plaque with bulb presence in carotid ultrasound from multiple scanners: Stroke risk assessment. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2017; 141:73-81. [PMID: 28241970 DOI: 10.1016/j.cmpb.2017.01.009] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 12/20/2016] [Accepted: 01/17/2017] [Indexed: 06/06/2023]
Abstract
BACKGROUND AND OBJECTIVES Standardization of the carotid IMT requires a reference marker in ultrasound scans. It has been shown previously that manual reference marker and manually created carotid segments are used for measuring IMT in these segments. Manual methods are tedious, time consuming, subjective, and prone to errors. Bulb edge can be considered as a reference marker for measurements of the cIMT. However, bulb edge can be difficult to locate in ultrasound scans due to: (a) low signal to noise ratio in the bulb region as compared to common carotid artery region; (b) uncertainty of bulb location in craniocaudal direction; and (c) variability in carotid bulb shape and size. This paper presents an automated system (a class of AtheroEdge™ system from AtheroPoint™, Roseville, CA, USA) for locating the bulb edge as a reference marker and further develop segmental-IMT (sIMT) which measures IMT in 10mm segments (namely: s1, s2 and s3) proximal to the bulb edge. METHODS The patented methodology uses an integrated approach which combines carotid geometry and pixel-classification paradigms. The system first finds the bulb edge and then measures the sIMT proximal to the bulb edge. The system also estimates IMT in bulb region (bIMT). The 649 image database consists of varying plaque (light, moderate to heavy), image resolutions, shapes, sizes and ethnicity. RESULTS Our results show that the IMT contributions in different carotid segments are as follows: bulb-IMT 34%, s1-IMT 29.46%, s2-IMT 11.48%, and s3-IMT 12.75%, respectively. We compare our automated results against reader's tracings demonstrating the following performance: mean lumen-intima error: 0.01235 ± 0.01224mm, mean media-adventitia error: 0.020933 ± 0.01539mm and mean IMT error: 0.01063 ± 0.0031mm. Our system's Precision of Merit is: 98.23%, coefficient of correlation between automated and Reader's IMT is: 0.998 (p-value < 0.0001). These numbers are improved compared to previous publications by Suri's group which is automated multi-resolution conventional cIMT. CONCLUSIONS Our fully automated bulb detection system reports 92.67% precision against ideal bulb edge locations as marked by the reader in the bulb transition zone.
Collapse
Affiliation(s)
- Nobutaka Ikeda
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, Japan
| | - Nilanjan Dey
- Point of Care Devices, Global Biomedical Technologies, Inc., Roseville, CA, USA
| | - Aditya Sharma
- Cardiovascular Medicine, University of Virginia, VA, USA
| | - Ajay Gupta
- Department of Radiology, Brain and Mind Research Institute, Weill Cornell Medical College, NY, USA
| | - Soumyo Bose
- Point of Care Devices, Global Biomedical Technologies, Inc., Roseville, CA, USA
| | - Suvojit Acharjee
- Point of Care Devices, Global Biomedical Technologies, Inc., Roseville, CA, USA
| | - Shoaib Shafique
- CorVasc Vascular Laboratory, 8433 Harcourt Rd #100, Indianapolis, IN, USA
| | | | - Tadashi Araki
- Division of Cardiovascular Medicine, Centre for Global Health and Medicine (NCGM), 1-21-1 Toyama Shinjuku-ku, Tokyo, Japan
| | - Luca Saba
- Azienda Ospedaliero Universitaria (A.O.U.) di Cagliari - Polo di Monserrato, Università di Cagliari, s.s. 554 Monserrato, Cagliari 09045, Italy
| | - John R Laird
- UC Davis Vascular Center, University of California, Davis, CA, USA
| | - Andrew Nicolaides
- Vascular Screening and Diagnostic Centre, London, and Department of Biological Sciences, University of Cyprus, Nicosia, Cyprus
| | - Jasjit S Suri
- Point of Care Devices, Global Biomedical Technologies, Inc., Roseville, CA, USA; Diagnostic and Monitoring Division, AtheroPoint™ LLC, Roseville, CA, USA; Electrical Engineering Department (Aff.), Idaho State University, ID, USA.
| |
Collapse
|