1
|
Heitzer M, Kilic K, Merfort R, Winnand P, Emonts C, Bock A, Ooms M, Steiner T, Hölzle F, Modabber A. Tensile strength of adhesives in peripheral nerve anastomoses: an in vitro biomechanical evaluation of four different neurorrhaphies. Eur J Med Res 2024; 29:264. [PMID: 38698476 PMCID: PMC11067280 DOI: 10.1186/s40001-024-01858-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Accepted: 04/24/2024] [Indexed: 05/05/2024] Open
Abstract
BACKGROUND The fundamental prerequisite for prognostically favorable postoperative results of peripheral nerve repair is stable neurorrhaphy without interruption and gap formation. METHODS This study evaluates 60 neurorrhaphies on femoral chicken nerves in terms of the procedure and the biomechanical properties. Sutured neurorrhaphies (n = 15) served as control and three sutureless adhesive-based nerve repair techniques: Fibrin glue (n = 15), Histoacryl glue (n = 15), and the novel polyurethane adhesive VIVO (n = 15). Tensile and elongation tests of neurorrhaphies were performed on a tensile testing machine at a displacement rate of 20 mm/min until failure. The maximum tensile force and elongation were recorded. RESULTS All adhesive-based neurorrhaphies were significant faster in preparation compared to sutured anastomoses (p < 0.001). Neurorrhaphies by sutured (102.8 [cN]; p < 0.001), Histoacryl (91.5 [cN]; p < 0.001) and VIVO (45.47 [cN]; p < 0.05) withstood significant higher longitudinal tensile forces compared to fibrin glue (10.55 [cN]). VIVO, with △L/L0 of 6.96 [%], showed significantly higher elongation (p < 0.001) compared to neurorrhaphy using fibrin glue. CONCLUSION Within the limitations of an in vitro study the adhesive-based neurorrhaphy technique with VIVO and Histoacryl have the biomechanical potential to offer alternatives to sutured neuroanastomosis because of their stability, and faster handling. Further in vivo studies are required to evaluate functional outcomes and confirm safety.
Collapse
Affiliation(s)
- Marius Heitzer
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany.
| | - Konrad Kilic
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Ricarda Merfort
- Department of Orthopedics, Trauma and Reconstructive Surgery, University Hospital of RWTH Aachen, Aachen, Germany
| | - Philipp Winnand
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Caroline Emonts
- Institute of Textile Technology, RWTH Aachen University, Otto-Blumenthal-Straße 1, 52074, Aachen, Germany
| | - Anna Bock
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Mark Ooms
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Timm Steiner
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Frank Hölzle
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Ali Modabber
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| |
Collapse
|
2
|
Eskildsen MPR, Kalliokoski O, Boennelycke M, Lundquist R, Settnes A, Loekkegaard E. An autologous blood-derived patch as a hemostatic agent: evidence from thromboelastography experiments and a porcine liver punch biopsy model. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2023; 34:20. [PMID: 37074487 PMCID: PMC10115690 DOI: 10.1007/s10856-023-06726-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 04/03/2023] [Indexed: 05/03/2023]
Abstract
Perioperative bleeding is a common complication in surgeries that increases morbidity, risk of mortality, and leads to increased socioeconomic costs. In this study we investigated a blood-derived autologous combined leukocyte, platelet, and fibrin patch as a new means of activating coagulation and maintaining hemostasis in a surgical setting. We evaluated the effects of an extract derived from the patch on the clotting of human blood in vitro, using thromboelastography (TEG). The autologous blood-derived patch activated hemostasis, seen as a reduced mean activation time compared to both non-activated controls, kaolin-activated samples, and fibrinogen/thrombin-patch-activated samples. The accelerated clotting was reproducible and did not compromise the quality or stability of the resulting blood clot. We also evaluated the patch in vivo in a porcine liver punch biopsy model. In this surgical model we saw 100% effective hemostasis and a significant reduction of the time-to-hemostasis, when compared to controls. These results were comparable to the hemostatic properties of a commercially available, xenogeneic fibrinogen/thrombin patch. Our findings suggest clinical potential for the autologous blood-derived patch as a hemostatic agent.
Collapse
Affiliation(s)
- Morten P R Eskildsen
- Department of Obstetrics and Gynecology, Copenhagen University Hospital - North Zealand, Hilleroed, Denmark.
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
- Department of Experimental Medicine, University of Copenhagen, Copenhagen, Denmark.
| | - Otto Kalliokoski
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Experimental Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Marie Boennelycke
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Pathology, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
| | | | - Annette Settnes
- Department of Obstetrics and Gynecology, Copenhagen University Hospital - North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Ellen Loekkegaard
- Department of Obstetrics and Gynecology, Copenhagen University Hospital - North Zealand, Hilleroed, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
3
|
Bremer L, Hagemeister K, Moss M, Ernst L, Tolba RH, Jockenhoevel S, Apel C. Long-Term Degradation Assessment of a Polyurethane-Based Surgical Adhesive-Assessment and Critical Consideration of Preclinical In Vitro and In Vivo Testing. J Funct Biomater 2023; 14:jfb14030168. [PMID: 36976092 PMCID: PMC10058192 DOI: 10.3390/jfb14030168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/08/2023] [Accepted: 03/18/2023] [Indexed: 03/29/2023] Open
Abstract
Tissue adhesives constitute a great possibility to improve conventional wound closure. In contrast to sutures, they enable nearly immediate hemostasis and can prevent fluid or air leaks. In the present study, a poly(ester)urethane-based adhesive was investigated which already proved to be suitable for different indications, such as reinforcing vascular anastomosis and sealing liver tissue. Using in vitro and in vivo setups, the degradation of the adhesives was monitored over a period of up to 2 years, to evaluate long-term biocompatibility and determine degradation kinetics. For the first time, the complete degradation of the adhesive was documented. In subcutaneous locations, tissue residues were found after 12 months and in intramuscular locations, tissue degradation was complete after about 6 months. A detailed histological evaluation of the local tissue reaction revealed good biocompatibility throughout the different degradation stages. After full degradation, complete remodeling to physiological tissue was observed at the implant locations. In addition, this study critically discusses common issues related to the assessment of biomaterial degradation kinetics in the context of medical device certification. This work highlighted the importance and encouraged the implementation of biologically relevant in vitro degradation models to replace animal studies or at least reduce the number of animals in preclinical testing prior to clinical studies. Moreover, the suitability of frequently used implantation studies based on ISO 10993-6 at standard locations was critically discussed, especially in light of the associated lack of reliable predictions for degradation kinetics at the clinically relevant site of implantation.
Collapse
Affiliation(s)
- Lisanne Bremer
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, 52074 Aachen, Germany
| | | | - Michaela Moss
- Institute for Laboratory Animal Science & Experimental Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany
| | - Lisa Ernst
- Institute for Laboratory Animal Science & Experimental Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany
| | - René H Tolba
- Institute for Laboratory Animal Science & Experimental Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, 52074 Aachen, Germany
| | - Christian Apel
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, 52074 Aachen, Germany
| |
Collapse
|
4
|
Heitzer M, Ooms M, Katz MS, Peters F, Kilic K, Tolba R, Jockenhoevel S, Hermanns-Sachweh B, Hölzle F, Modabber A. Evaluation of the long-term results of vascular anastomosis using polyurethane adhesive and shape-memory stent in the rat carotid artery model. Microsurgery 2022; 42:480-489. [PMID: 35670105 DOI: 10.1002/micr.30926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 04/04/2022] [Accepted: 05/20/2022] [Indexed: 11/11/2022]
Abstract
INTRODUCTION In free flaps, 5%-10% of complications are related to failure of sutured vascular anastomoses. Adhesive-based microvascular anastomoses are potential alternatives but are associated with failure rates of 70% in research studies. VIVO is a new adhesive with slow biodegradation within 6 months that has shown a 100% patency rate in research studies over 2 h observation time but long-term patency has not been evaluated. The authors hypothesize that VIVO will enable a reliable microvascular procedure comparable to sutured anastomoses over a 28-day period. MATERIALS AND METHODS The right common carotid artery of 60 male Sprague Dawley rats, ~450 g, were used for microvascular end-to-end anastomosis. VIVO was applied with reduced sutures with a temporary catheter in one group and in the other with a custom-shaped memory stent. Anastomoses with eight interrupted sutures served as control. All groups were n = 20. Anastomosis time and bleeding were recorded for each procedure. Doppler flowmetry was performed 20 min, 1, 10, and 28 days postoperatively. Postmortem toluidine staining was used for semi-quantitative analysis of stenosis, thrombosis, necrosis, and aneurysm formation by histologic evaluation. RESULTS No occlusion was detected 20 min and 1 day postoperative, and after 28 days of observation in all anastomoses. The anastomosis time of the VIVO with catheter group was about 32% significantly faster than the VIVO with stent group. In the VIVO group with stent, the bleeding time was ~80% shorter than in the control group with 2.1 ± 0.3 and VIVO with catheter 2.0 ± 0.5 (p ≤ .001 each). Minor and nonsignificant stent-associated thrombus formation and stent-typical intraluminal stenosis were detected exclusively in the VIVO with stent group. CONCLUSION Within the limitations of a rat study, the use of VIVO in anastomosis showed promising results. VIVO with catheter was found to be advantageous.
Collapse
Affiliation(s)
- Marius Heitzer
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - Mark Ooms
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - Marie Sophie Katz
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - Florian Peters
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - Konrad Kilic
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - René Tolba
- Institute of Laboratory Animal Science and Experimental Surgery of RWTH-Aachen, Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid and Medical Textiles (BioTex), AME-Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | | | - Frank Hölzle
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| | - Ali Modabber
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Aachen, Germany
| |
Collapse
|
5
|
Schulten L, Spillner J, Kanzler S, Teubner A, Jockenhoevel S, Apel C. A polyurethane-based surgical adhesive for sealing blood vessel anastomoses-A feasibility study in pigs. J Biomed Mater Res B Appl Biomater 2022; 110:1922-1931. [PMID: 35293688 DOI: 10.1002/jbm.b.35049] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 02/24/2022] [Accepted: 03/03/2022] [Indexed: 12/14/2022]
Abstract
Peri- and postoperative anastomotic leakage from blood vessel anastomosis is a common and potentially life-threatening complication. As an adjunctive therapy providing an additional layer of safety, a new biodegradable, polyurethane-based adhesive was developed. It consists of two components: an isocyanate-functionalized prepolymer and an amino-based curing agent. The adhesive was investigated in a porcine animal model to seal sutured blood vessel anastomoses of arteries, veins, aortas and prosthetic aortic graft replacements. The material-determined properties of the adhesive like viscosity, processing and polymerization time as well as bonding strength were well suited for this application. The adhesive stopped perioperative suture-line bleedings and stayed on all anastomoses until sacrifice. Hematological and serological inflammation marker assessments were unobtrusive. The histological evaluation showed a mild to moderate local tissue reaction to the adhesive constituting a physiological, non-adverse tissue-biomaterial interaction. The adhesive did not interfere with vascular wound healing. The adhesive demonstrated to be suitable to improve the outcome of cardiovascular surgeries by securing the classical sutured anastomoses in a fast, easy and safe manner. However, further studies are required to quantitatively evaluate efficacy in terms of anastomotic leakage prevention as well as long-term tissue compatibility and degradation.
Collapse
Affiliation(s)
- Lisanne Schulten
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | - Jan Spillner
- Clinic for Thoracic and Cardiovascular Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | | | - Andreas Teubner
- Central Animal Facility, Faculty of Health, Medicine & Life Sciences, Maastricht University, Maastricht, The Netherlands
| | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | - Christian Apel
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
6
|
Modabber A, Winnand P, Goloborodko E, Möhlhenrich SC, Kniha K, Tolba R, Jockenhoevel S, Hermanns-Sachweh B, Hölzle F, Heitzer M. Biodegradation and Immunological Parameters of Polyurethane-based Tissue Adhesive in Arterial Microvascular Anastomoses - a Long-term in Vivo Study. Macromol Biosci 2022; 22:e2100451. [PMID: 35080346 DOI: 10.1002/mabi.202100451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 01/16/2022] [Indexed: 11/07/2022]
Abstract
In microsurgical anastomosis, non-synthetic fibrin-based adhesives have predominantly shown superior properties to synthetic cyanoacrylates, but they have hardly any clinical application. This study aimed to investigate the local and systemic effects of synthetically produced biodegradable adhesive VIVO when used in microsurgical anastomosis. VIVO was used in two different anastomosis procedures in the common carotid artery in a rat model: VIVO in addition to a temporary catheter (VIVO TC) and VIVO with a custom-shaped memory nitinol stent (VIVO SM). Conventionally sutured anastomoses served as controls (C). Tissue response was assessed by in vivo fluorescence imaging and histological examination. The systemic effects of biodegradation were measured using hematologic parameters and serum levels of transaminase activity and lactate dehydrogenase. Finally, the degree of local adhesion of the different anastomotic procedures was evaluated. Fluorescence imaging showed reduced inflammatory blood flow in the VIVO TC group. Histological analysis of the anastomosed vessels also revealed significantly more inflammation in C than in the two adhesive groups. The severity of VIVO adhesions proved acceptable, and no histotoxic effects of VIVO were detected. The data demonstrated that the synthetic tissue adhesive VIVO is a reliable and- compared to sutures-tissue-friendly adhesive for microsurgical anastomoses. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Ali Modabber
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.,Head & Chairman Univ. Prof. Dr. med. Dr. med. dent. Frank Hölzle
| | - Philipp Winnand
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.,Head & Chairman Univ. Prof. Dr. med. Dr. med. dent. Frank Hölzle
| | - Evgeny Goloborodko
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.,Head & Chairman Univ. Prof. Dr. med. Dr. med. dent. Frank Hölzle
| | - Stephan Christian Möhlhenrich
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.,Head & Chairman Univ. Prof. Dr. med. Dr. med. dent. Frank Hölzle.,Department of Orthodontics, University of Witten/Herdecke, Alfred-Herrhausen Str. 45, Witten, 58455, Germany.,Head & Chairman Univ.-Prof. Dr. med. dent. Golamreza Danesh
| | - Kristian Kniha
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.,Head & Chairman Univ. Prof. Dr. med. Dr. med. dent. Frank Hölzle
| | - René Tolba
- Institute of Laboratory Animal Science and Experimental Surgery of RWTH-Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.,Head & Chairman Univ.-Prof. Dr. med. René H. Tolba
| | - Stefan Jockenhoevel
- Department of Biohybrid and Medical Textiles (BioTex), AME-Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Aachen, 52074, Germany
| | - Benita Hermanns-Sachweh
- Implant Pathology ZBMT, Campus Melaten, Pauwelsstraße 17, Aachen, 52074.,Prof. Dr. med. Benita Hermanns-Sachweh
| | - Frank Hölzle
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.,Head & Chairman Univ. Prof. Dr. med. Dr. med. dent. Frank Hölzle
| | - Marius Heitzer
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, Aachen, 52074, Germany.,Head & Chairman Univ. Prof. Dr. med. Dr. med. dent. Frank Hölzle
| |
Collapse
|
7
|
Kalverkamp S, Mantas A, Spillner J, Hima F, Kanzler SS, Stopinski T, Tolba RH, Zayat R. Efficacy of a Novel Medical Adhesive for Sealing Lung Parenchyma: An in vitro Study in Rabbit Lungs. Eur Surg Res 2021; 62:255-261. [PMID: 34289469 DOI: 10.1159/000517173] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Accepted: 05/12/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION During thoracic resection procedures, complete hemostasis and aerostasis are priorities. A persistent alveolar air leak is associated with increased morbidity and mortality rates. This study aimed to evaluate whether the novel medical adhesive VIVO (Adhesys Medical GmbH Aachen, Germany) is a reliable alternative sealing technique to routine surgical procedures. METHODS We conducted an in vitro animal study by analyzing 21 lungs of New Zealand (n = 19) and Chinchilla Bastard (n = 2) rabbits (age, 11-18 weeks; weight, 2,400-3,600 g). Three groups, each comprising 7 animals, were evaluated. VIVO (VIVO-group) was compared with standard surgical lung parenchymal lesion closure with a polypropylene suture (Suture-group) and TachoSil® (TachoSil-group). We adopted a stable, pressure-controlled ventilation protocol. After explantation, a surgical incision 0.5-cm deep and 1.5-cm wide was made in the lungs using a customized template. Air leak was measured quantitatively (mL/min) using a respirator and visualized qualitatively by 2 observers who made independent judgments. Next, the leak was closed using VIVO, suture, or TachoSil® as specified by the manufacturer. Subsequently, positive end-expiratory pressure (PEEP) and inspiratory pressure were gradually increased until a maximum of 15 and 30 mbar were attained, respectively. RESULTS At PEEPs of 8, 10, and 15 mbar, VIVO achieved complete sealing of the profound parenchymal defect in all (n = 7) lungs. After closure of the incision, we observed an air leak variation of 127 ± 114 mL/min (Suture-group), 31 ± 49 mL/min (VIVO-group), and 114 ± 134 mL/min (TachoSil-group). VIVO showed a significantly lower air leak than surgical sutures (p = 0.031) and TachoSil® (p = 0.046). CONCLUSION VIVO offers sufficient closure of the lung parenchymal lesions. The novel adhesive enabled significantly better sealing with lower persistent air leakage than TachoSil® or surgical sutures. Further investigation using in vivo models is strongly encouraged to confirm our findings.
Collapse
Affiliation(s)
- Sebastian Kalverkamp
- Department of Thoracic and Cardiovascular Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - Anna Mantas
- Department of Thoracic and Cardiovascular Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - Jan Spillner
- Department of Thoracic and Cardiovascular Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - Flutura Hima
- Department of Thoracic and Cardiovascular Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | | | - Thaddäus Stopinski
- Institute for Laboratory Animal Science & Experimental Surgery, RWTH Aachen, University Hospital RWTH Aachen, Aachen, Germany
| | - René H Tolba
- Institute for Laboratory Animal Science & Experimental Surgery, RWTH Aachen, University Hospital RWTH Aachen, Aachen, Germany
| | - Rashad Zayat
- Department of Thoracic and Cardiovascular Surgery, University Hospital RWTH Aachen, Aachen, Germany
| |
Collapse
|
8
|
Heitzer M, Brockhaus J, Kniha K, Merkord F, Peters F, Hölzle F, Goloborodko E, Modabber A. Mechanical strength and hydrostatic testing of VIVO adhesive in sutureless microsurgical anastomoses: an ex vivo study. Sci Rep 2021; 11:13598. [PMID: 34193930 PMCID: PMC8245481 DOI: 10.1038/s41598-021-92998-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 06/15/2021] [Indexed: 11/09/2022] Open
Abstract
Conventional anastomoses with interrupted sutures are challenging and inevitably associated with trauma to the vessel walls. The goal of this study was to evaluate a novel alternative adhesive-based suture-free anastomosis technique that uses an intraluminal stent. Overall, 120 porcine coronary vessels were analyzed in an ex vivo model and were examined for their mechanical (n = 20 per cohort) and hydrostatic strength (n = 20 per cohort). Anastomoses were made using the novel VIVO adhesive with an additional intraluminal nitinol stent and was compared to interrupted suture anastomosis and to native vessels. Sutureless anastomoses withstood pressures 299 ± 4.47 [mmHg] comparable to native vessels. They were performed significantly faster 553.8 ± 82.44 [sec] (p ≤ 0.001) and withstood significantly higher pressures (p ≤ 0.001) than sutured anastomoses. We demonstrate that the adhesive-based anastomosis can also resist unphysiologically high longitudinal tensile forces with a mean of 1.33 [N]. Within the limitations of an in vitro study adhesive-based suture-free anastomosis technique has the biomechanical potential to offer a seamless alternative to sutured anastomosis because of its stability, and faster handling. In vivo animal studies are needed to validate outcomes and confirm safety.
Collapse
Affiliation(s)
- Marius Heitzer
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany.
| | - Julia Brockhaus
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Kristian Kniha
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Felix Merkord
- Institute of Textile Technology, RWTH Aachen University, Aachen, Germany
| | - Florian Peters
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Frank Hölzle
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Evgeny Goloborodko
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| | - Ali Modabber
- Department of Oral and Maxillofacial Surgery, University Hospital of RWTH Aachen, Pauwelsstraße 13, 52074, Aachen, Germany
| |
Collapse
|
9
|
Heitzer M, Möhlhenrich SC, Kniha K, Tolba R, Jockenhoevel S, Hölzle F, Modabber A. Microvascular anastomosis techniques using the medical adhesive VIVO and expandable micro-stents in a rat carotid artery model. Ann Anat 2021; 238:151782. [PMID: 34144156 DOI: 10.1016/j.aanat.2021.151782] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 05/21/2021] [Accepted: 05/24/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND Sutured anastomosis remains the gold standard in microvascular surgery. The procedure is not free of complications and is a time-consuming operation requiring a high level of experience. The aim of this study was to develop new methods for a stable, faster, and safer anastomosis using a novel biodegradable adhesive, VIVO, and a custom-made microvascular stent. METHODS The VIVO medical adhesive was used for a total of 30 anastomoses in rats in the right carotid artery: 15 anastomoses were performed with a temporary intraluminal catheter, VIVO, and reduced sutures (VIVO + TC). A further 15 anastomoses were performed with nitinol stents, VIVO, and reduced sutures (VIVO + SM). Sutured anastomoses served as controls (C) and were performed on the left carotid arteries of the 30 rats. Operation and bleeding times were assessed, and patency was evaluated by Doppler flowmetry and indocyanine green (ICG) angiography. Subsequently, the anastomoses were evaluated histopathological. RESULTS The overall patency was recorded as 100% in all groups. No thrombosis or circulatory disturbance was found. Compared to C and VIVO + SM, VIVO + TC proved to be significantly less traumatic, less demanding, and time-saving. The sealing properties of VIVO lead to shorter bleeding times and less oozing. In contrast, VIVO + SM proved to be the most technically demanding and time-consuming procedure. CONCLUSION The success of a microvascular sutured anastomosis is determined by a short ischemic interval. Compared to sutured anastomosis, VIVO + TC showed ease of use as well as shorter time taken for anastomosis, less trauma, and lower blood loss. More long-term studies on the functions, biological interactions, and survival rates of glue-based anastomoses need to be initiated.
Collapse
Affiliation(s)
- Marius Heitzer
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074 Aachen, Germany.
| | - Stephan Christian Möhlhenrich
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074 Aachen, Germany; Department of Orthodontics, University of Witten/Herdecke, Alfred-Herrhausen Str. 45, 58455 Witten, Germany
| | - Kristian Kniha
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074 Aachen, Germany
| | - René Tolba
- Institute of Laboratory Animal Science and Experimental Surgery of RWTH-Aachen, Pauwelsstraße 30, 52074 Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid and Medical Textiles (BioTex), AME-Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, 52074 Aachen, Germany
| | - Frank Hölzle
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074 Aachen, Germany
| | - Ali Modabber
- Department of Oral and Maxillofacial Surgery, University Hospital of Aachen, Pauwelsstraße 30, 52074 Aachen, Germany
| |
Collapse
|
10
|
Lada E, Anna M, Patrik M, Zbynek T, Miroslav J, Hynek M, Richard P, Sarah L, Vaclav L. Porcine Liver Anatomy Applied to Biomedicine. J Surg Res 2020; 250:70-79. [DOI: 10.1016/j.jss.2019.12.038] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2019] [Revised: 12/16/2019] [Accepted: 12/28/2019] [Indexed: 02/06/2023]
|
11
|
Fukushima K, Tanaka H, Kadaba Srinivasan P, Pawlowsky K, Kögel B, Uemoto S, Ku Y, Tolba R. Hemostatic Efficacy and Safety of the Novel Medical Adhesive, MAR VIVO-107, in a Rabbit Liver Resection Model. Eur Surg Res 2018; 59:48-57. [DOI: 10.1159/000481818] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Accepted: 09/25/2017] [Indexed: 11/19/2022]
Abstract
Background: Topical hemostatic agents are useful when hepatic hemorrhage is difficult to control. The aim of this study was to evaluate the hemostatic efficacy and safety of a biodegradable polyurethane-based adhesive, MAR VIVO-107 (MAR), in comparison with a clinically used fibrin glue. Methods: Thirty female New Zealand white rabbits were randomly assigned to 3 study groups as follows: MAR (n = 10), fibrin glue (n = 10), and saline groups (n = 10). After standardized partial liver resection was performed, each agent was immediately applied to the wound area. Bleeding time until hemostasis and blood loss were recorded. After 7 days, body weight, hematology parameters, and serum levels of aspartate aminotransferase, alanine aminotransferase, and lactate dehydrogenase were measured. Simultaneously, the severity of intra-abdominal adhesion was evaluated. Results: The mean bleeding time in the MAR (38 ± 10 s) and fibrin glue groups (65 ± 17 s) was significantly shorter than that in the saline group (186 ± 12 s). Similarly, the mean blood loss in the MAR (9 ± 3 g) and fibrin glue groups (9 ± 3 g) was significantly less than that in the saline group (23 ± 4 g). No significant differences in bleeding time and blood loss were found between the MAR and fibrin glue groups. The postoperative survival rate was 100% in all the groups. Body weight as well as hematological and serum biochemical values on day 7 were within the small and physiological range when compared with the preoperative baseline values, and significant differences were not detected among the MAR, fibrin glue, and saline groups. The severities of adhesion were similar between the 3 groups. Conclusion: Our data demonstrated that MAR was not inferior to fibrin glue in terms of hemostatic efficacy and safety.
Collapse
|