1
|
Karimi A, Khan S, Razaghi R, Rahmati SM, Gathara M, Tudisco E, Aga M, Kelley MJ, Jian Y, Acott TS. Developing an experimental-computational workflow to study the biomechanics of the human conventional aqueous outflow pathway. Acta Biomater 2023; 164:346-362. [PMID: 37072067 PMCID: PMC10226761 DOI: 10.1016/j.actbio.2023.04.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 03/29/2023] [Accepted: 04/06/2023] [Indexed: 04/20/2023]
Abstract
The aqueous humor actively interacts with the trabecular meshwork (TM), juxtacanalicular tissue (JCT), and Schlemm's canal (SC) through a dynamic fluid-structure interaction (FSI) coupling. Despite the fact that intraocular pressure (IOP) undergoes significant fluctuations, our understanding of the hyperviscoelastic biomechanical properties of the aqueous outflow tissues is limited. In this study, a quadrant of the anterior segment from a normal human donor eye was dynamically pressurized in the SC lumen, and imaged using a customized optical coherence tomography (OCT). The TM/JCT/SC complex finite element (FE) with embedded collagen fibrils was reconstructed based on the segmented boundary nodes in the OCT images. The hyperviscoelastic mechanical properties of the outflow tissues' extracellular matrix with embedded viscoelastic collagen fibrils were calculated using an inverse FE-optimization method. Thereafter, the 3D microstructural FE model of the TM, with adjacent JCT and SC inner wall, from the same donor eye was constructed using optical coherence microscopy and subjected to a flow load-boundary from the SC lumen. The resultant deformation/strain in the outflow tissues was calculated using the FSI method, and compared to the digital volume correlation (DVC) data. TM showed larger shear modulus (0.92 MPa) compared to the JCT (0.47 MPa) and SC inner wall (0.85 MPa). Shear modulus (viscoelastic) was larger in the SC inner wall (97.65 MPa) compared to the TM (84.38 MPa) and JCT (56.30 MPa). The conventional aqueous outflow pathway is subjected to a rate-dependent IOP load-boundary with large fluctuations. This necessitates addressing the biomechanics of the outflow tissues using hyperviscoelastic material-model. STATEMENT OF SIGNIFICANCE: While the human conventional aqueous outflow pathway is subjected to a large-deformation and time-dependent IOP load-boundary, we are not aware of any studies that have calculated the hyperviscoelastic mechanical properties of the outflow tissues with embedded viscoelastic collagen fibrils. A quadrant of the anterior segment of a normal humor donor eye was dynamically pressurized from the SC lumen with relatively large fluctuations. The TM/JCT/SC complex were OCT imaged and the mechanical properties of the tissues with embedded collagen fibrils were calculated using the inverse FE-optimization algorithm. The resultant displacement/strain in the FSI outflow model was validated versus the DVC data. The proposed experimental-computational workflow may significantly contribute to understanding of the effects of different drugs on the biomechanics of the conventional aqueous outflow pathway.
Collapse
Affiliation(s)
- Alireza Karimi
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - Shanjida Khan
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - Reza Razaghi
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| | | | - Michael Gathara
- Department of Computer Science, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Erika Tudisco
- Division of Geotechnical Engineering, Lund University, Lund, Sweden
| | - Mini Aga
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - Mary J Kelley
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA; Department Integrative Biosciences, School of Dentistry, Oregon Health & Science University, Portland, OR, USA
| | - Yifan Jian
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA; Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - Ted S Acott
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA; Department Chemical Physiology & Biochemistry, School of Medicine, Oregon Health & Science University, Portland, OR, USA.
| |
Collapse
|
2
|
Lynch S, Nama N, Figueroa CA. Effects of non-Newtonian viscosity on arterial and venous flow and transport. Sci Rep 2022; 12:20568. [PMID: 36446813 PMCID: PMC9709089 DOI: 10.1038/s41598-022-19867-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Accepted: 09/06/2022] [Indexed: 11/30/2022] Open
Abstract
It is well known that blood exhibits non-Newtonian viscosity, but it is generally modeled as a Newtonian fluid. However, in situations of low shear rate, the validity of the Newtonian assumption is questionable. In this study, we investigated differences between Newtonian and non-Newtonian hemodynamic metrics such as velocity, vorticity, and wall shear stress. In addition, we investigated cardiovascular transport using two different approaches, Eulerian mass transport and Lagrangian particle tracking. Non-Newtonian solutions revealed important differences in both hemodynamic and transport metrics relative to the Newtonian model. Most notably for the hemodynamic metrics, in-plane velocity and vorticity were consistently larger in the Newtonian approximation for both arterial and venous flows. Conversely, wall shear stresses were larger for the non-Newtonian case for both the arterial and venous models. Our results also indicate that for the Lagrangian metrics, the history of accumulated shear was consistently larger for both arterial and venous flows in the Newtonian approximation. Lastly, our results also suggest that the Newtonian model produces larger near wall and luminal mass transport values compared to the non-Newtonian model, likely due to the increased vorticity and recirculation. These findings demonstrate the importance of accounting for non-Newtonian behavior in cardiovascular flows exhibiting significant regions of low shear rate and recirculation.
Collapse
Affiliation(s)
- Sabrina Lynch
- grid.214458.e0000000086837370Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI USA
| | - Nitesh Nama
- grid.24434.350000 0004 1937 0060Department of Mechanical & Materials Engineering, University of Nebraska, Lincoln, NE USA
| | - C. Alberto Figueroa
- grid.214458.e0000000086837370Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI USA ,grid.214458.e0000000086837370Department of Surgery, University of Michigan, Ann Arbor, MI USA
| |
Collapse
|
3
|
Karimi A, Razaghi R, Rahmati SM, Downs JC, Acott TS, Wang RK, Johnstone M. Modeling the biomechanics of the conventional aqueous outflow pathway microstructure in the human eye. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 221:106922. [PMID: 35660940 PMCID: PMC10424784 DOI: 10.1016/j.cmpb.2022.106922] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 05/16/2022] [Accepted: 05/26/2022] [Indexed: 05/27/2023]
Abstract
BACKGROUND AND OBJECTIVE Intraocular pressure (IOP) is determined by aqueous humor outflow resistance, which is a function of the combined resistance of Schlemm's canal (SC) endothelium and the trabecular meshwork (TM) and their interactions in the juxtacanalicular connective tissue (JCT) region. Aqueous outflow in the conventional outflow pathway results in pressure gradient across the TM, JCT, and SC inner wall, and induces mechanical stresses and strains that influence the geometry and homeostasis of the outflow system. The outflow resistance is affected by alteration in tissues' geometry, so there is potential for active, two-way, fluid-structure interaction (FSI) coupling between the aqueous humor (fluid) and the TM, JCT, and SC inner wall (structure). However, our understanding of the biomechanical interactions of the aqueous humor with the outflow connective tissues and its contribution to the outflow resistance regulation is incomplete. METHODS In this study, a microstructural finite element (FE) model of a human eye TM, JCT, and SC inner wall was constructed from a segmented, high-resolution histologic 3D reconstruction of the human outflow system. Three different elastic moduli (0.004, 0.128, and 51.5 MPa based on prior reports) were assigned to the TM/JCT complex while the elastic modulus of the SC inner wall was kept constant at 0.00748 MPa. The hydraulic conductivity was programmed separately for the TM, JCT, and SC inner wall using a custom subroutine. Cable elements were embedded into the TM and JCT extracellular matrix to represent the directional stiffness imparted by anisotropic collagen fibril orientation. The resultant stresses and strains in the outflow system were calculated using fluid-structure interaction method. RESULTS The higher TM/JCT stiffness resulted in larger stresses, but smaller strains in the outflow connective tissues, and resulted in a 4- and 5-fold larger pressure drop across the SC inner wall, respectively, compared to the most compliant model. Funneling through µm-sized SC endothelial pores was evident in the models at lower tissue stiffness, but aqueous flow was more turbulent in models with higher TM/JCT stiffness. CONCLUSIONS The mechanical properties of the outflow tissues play a crucial role in the hydrodynamics of the aqueous humor in the conventional outflow system.
Collapse
Affiliation(s)
- Alireza Karimi
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, 1670 University Boulevard, VH 372B, Birmingham, AL 35294, USA.
| | - Reza Razaghi
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, 1670 University Boulevard, VH 372B, Birmingham, AL 35294, USA
| | | | - J Crawford Downs
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, 1670 University Boulevard, VH 372B, Birmingham, AL 35294, USA
| | - Ted S Acott
- Ophthalmology and Biochemistry and Molecular Biology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
| | - Ruikang K Wang
- Department of Ophthalmology, University of Washington, Seattle, WA, USA; Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Murray Johnstone
- Department of Ophthalmology, University of Washington, Seattle, WA, USA
| |
Collapse
|
4
|
Alizadehghobadi S, Biglari H, Niroomand-Oscuii H, Matin MH. Numerical study of hemodynamics in a complete coronary bypass with venous and arterial grafts and different degrees of stenosis. Comput Methods Biomech Biomed Engin 2020; 24:883-896. [PMID: 33307817 DOI: 10.1080/10255842.2020.1857744] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Cardiovascular diseases are among the leading causes of death in the world. The coronary blockage is one of most common types of these diseases that in the majority of cases has been treated by bypass surgery. In the bypass surgery, a graft is implemented to alter the blocked coronary and allow the blood supply process. The hemodynamic characteristics of the bypass strongly depend on the geometry and mechanical properties of the graft. In the present study, the fluid-structure interaction (FSI) analysis is conducted to investigate the bypass performance for a thoracic artery as well as a saphenous vein graft. Blood flow introduces a pressure on the walls of the graft which behaves as a hyperelastic material. A complete coronary bypass with stenosis degrees of 70% and 100% is modeled. To consider the nonlinear stress-strain behavior of the grafts, a five parameter Mooney-Rivlin hyperplastic model is implemented for the structural analysis and blood is assumed to behave as a Newtonian fluid. The simulations are performed for a structured grid to solve the governing equations using finite element method (FEM). The results show that wall shear stress (WSS) for saphenous vein is larger than that of thoracic artery while the total deformation of the thoracic artery is larger compared to the saphenous vein. Also, for the venous grafts or lower stenosis degree, the oscillatory shear index (OSI) is higher at both left and right anastomoses meaning that venous grafts as well as lower degree of stenosis are more critical in terms of restenosis.
Collapse
Affiliation(s)
| | - Hasan Biglari
- Department of Mechanical Engineering, University of Tabriz, Tabriz, Iran
| | | | - Meisam H Matin
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL, USA
| |
Collapse
|
5
|
Hajati Z, Sadegh Moghanlou F, Vajdi M, Razavi SE, Matin S. Fluid-structure interaction of blood flow around a vein valve. BIOIMPACTS 2020; 10:169-175. [PMID: 32793439 PMCID: PMC7416012 DOI: 10.34172/bi.2020.21] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Revised: 11/09/2019] [Accepted: 12/14/2019] [Indexed: 11/09/2022]
Abstract
Introduction: Venous valves are a type of one-way valves which conduct blood flow toward the heart and prevent its backflow. Any malfunction of these organs may cause serious problems in the circulatory system. Numerical simulation can give us detailed information and point to point data such as velocity, wall shear stress, and von Mises stress from veins with small diameters, as obtaining such data is almost impossible using current medical devices. Having detailed information about fluid flow and valves' function can help the treatment of the related diseases. Methods: In the present work, the blood flow through a venous valve considering the flexibility of the vein wall and valve leaflets is investigated numerically. The governing equations of fluid flow and solid domain are discretized and solved by the Galerkin finite element method. Results: The obtained results showed that the blood velocity increases from inlet to the leaflets and then decreases passing behind the valve. A pair of vortices and the trapped region was observed just behind the valves. These regions have low shear stresses and are capable of sediment formation. Conclusion: The von Mises stress which is a criterion for the breakdown of solid materials was obtained. It was also observed that a maximum value occurred at the bottom of the leaflets.
Collapse
Affiliation(s)
- Zahra Hajati
- Faculty of Engineering, University of Mohaghegh Ardabili, Ardabil, Iran
| | | | - Mohammad Vajdi
- Faculty of Engineering, University of Mohaghegh Ardabili, Ardabil, Iran
| | | | - Somaieh Matin
- Department of Internal Medicine, Ardabil University of Medical Sciences, Ardabil, Iran
| |
Collapse
|
6
|
Steuer NB, Hugenroth K, Beck T, Spillner J, Kopp R, Reinartz S, Schmitz-Rode T, Steinseifer U, Wagner G, Arens J. Long-Term Venovenous Connection for Extracorporeal Carbon Dioxide Removal (ECCO 2R)-Numerical Investigation of the Connection to the Common Iliac Veins. Cardiovasc Eng Technol 2020; 11:362-380. [PMID: 32405926 PMCID: PMC7385029 DOI: 10.1007/s13239-020-00466-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 05/02/2020] [Indexed: 02/06/2023]
Abstract
Purpose Currently used cannulae for extracorporeal carbon dioxide removal (ECCO2R) are associated with complications such as thrombosis and distal limb ischemia, especially for long-term use. We hypothesize that the risk of these complications is reducible by attaching hemodynamically optimized grafts to the patient’s vessels. In this study, as a first step towards a long-term stable ECCO2R connection, we investigated the feasibility of a venovenous connection to the common iliac veins. To ensure its applicability, the drainage of reinfused blood (recirculation) and high wall shear stress (WSS) must be avoided. Methods A reference model was selected for computational fluid dynamics, on the basis of the analysis of imaging data. Initially, a sensitivity analysis regarding recirculation was conducted using as variables: blood flow, the distance of drainage and return to the iliocaval junction, as well as the diameter and position of the grafts. Subsequently, the connection was optimized regarding recirculation and the WSS was evaluated. We validated the simulations in a silicone model traversed by dyed fluid. Results The simulations were in good agreement with the validation measurements (mean deviation 1.64%). The recirculation ranged from 32.1 to 0%. The maximum WSS did not exceed 5.57 Pa. The position and diameter of the return graft show the highest influence on recirculation. A correlation was ascertained between recirculation and WSS. Overall, an inflow jet directed at a vessel wall entails not only high WSS, but also a flow separation and thereby an increased recirculation. Therefore, return grafts aligned to the vena cava are crucial. Conclusion In conclusion, a connection without recirculation could be feasible and therefore provides a promising option for a long-term ECCO2R connection.
Collapse
Affiliation(s)
- N B Steuer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
| | - K Hugenroth
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - T Beck
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - J Spillner
- Clinic for Cardiothoracic Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - R Kopp
- Department of Anesthesiology, University Hospital RWTH Aachen, Aachen, Germany
| | - S Reinartz
- Department of Radiology, University Hospital RWTH Aachen, Aachen, Germany
| | - T Schmitz-Rode
- Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - U Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - G Wagner
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - J Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.,Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, Enschede, The Netherlands
| |
Collapse
|
7
|
In Vitro Validation of a Numerical Simulation of Leaflet Kinematics in a Polymeric Aortic Valve Under Physiological Conditions. Cardiovasc Eng Technol 2018; 9:42-52. [DOI: 10.1007/s13239-018-0340-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2017] [Accepted: 01/05/2018] [Indexed: 10/18/2022]
|
8
|
Bahreinizad H, Salimi Bani M, Khosravi A, Karimi A. A numerical study on the application of the functionally graded bioabsorbable materials in the stent design. Artery Res 2018. [DOI: 10.1016/j.artres.2018.09.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
9
|
Khosravi A, Bahreinizad H, Bani MS, Karimi A. A numerical study on the application of the functionally graded materials in the stent design. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 73:182-188. [PMID: 28183596 DOI: 10.1016/j.msec.2016.12.034] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 11/08/2016] [Accepted: 12/07/2016] [Indexed: 11/25/2022]
Abstract
Undesirable deformation of the stent can induce a significant amount of injure not only to the blood vessel but also to the plaque. The objective of this study was to reduce/minimize these undesirable deformations by the application of Functionally Graded Materials (FGM). To do this, Finite Element (FE) method was employed to simulate the expansion of a stent and the corresponding displacement of the stenosis plaque. Three hyperelastic plaque types as well as five elastoplastic stents were simulated. Dogboning, foreshortening, maximum stress in the plaque, and the pressure which is needed to fully expand the stent for different stent materials, were acquired. While all FGMs had lower dogboning in comparison to the stents made of the uniform materials, the stent with the lowest heterogeneous index displayed the lowest amount of dogboning. Steel stent showed the lowest foreshortening and fully expansion pressure but the difference was much lower than that the one for dogboning. Therefore, the FGM with the heterogeneous index of 0.5 is expected to exhibit the most suitable results. In addition, the results revealed that the material parameters has crucial effects on the deformation of the stent and, as a result, as a design point of view the FGM parameters can be tailored to achieve the goal of the biomechanical optimization.
Collapse
Affiliation(s)
- Arezoo Khosravi
- Atherosclerosis Research Center, Baqiyatallah University of Medical science, Tehran, Iran
| | - Hossein Bahreinizad
- Mechanical Engineering Department, Sahand University of Technology, Tabriz, Iran
| | - Milad Salimi Bani
- Mechanical Engineering Department, Iran University of Science and Technology, Tehran, Iran.
| | | |
Collapse
|
10
|
Karimi A, Rahmati SM, Sera T, Kudo S, Navidbakhsh M. A Combination of Constitutive Damage Model and Artificial Neural Networks to Characterize the Mechanical Properties of the Healthy and Atherosclerotic Human Coronary Arteries. Artif Organs 2017; 41:E103-E117. [PMID: 28150399 DOI: 10.1111/aor.12855] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 06/29/2016] [Indexed: 01/10/2023]
Abstract
It has been indicated that the content and structure of the elastin and collagen of the arterial wall can subject to a significant alteration due to the atherosclerosis. Consequently, a high tissue stiffness, stress, and even damage/rupture are triggered in the arterial wall. Although many studies so far have been conducted to quantify the mechanical properties of the coronary arteries, none of them consider the role of collagen damage of the healthy and atherosclerotic human coronary arterial walls. Recently, a fiber family-based constitutive equation was proposed to capture the anisotropic mechanical response of the healthy and atherosclerotic human coronary arteries via both the histostructural and uniaxial data. In this study, experimental mechanical measurements along with histological data of the healthy and atherosclerotic arterial walls were employed to determine the constitutive damage parameters and remodeling of the collagen fibers. To do this, the preconditioned arterial tissues were excised from human cadavers within 5-h postmortem, and the mean angle of their collagen fibers was precisely determined. Thereafter, a group of quasistatic axial and circumferential loadings were applied to the arterial walls, and the constrained nonlinear minimization method was employed to identify the arterial parameters according to the axial and circumferential extension data. The remodeling of the collagen fibers during the tensile test was also predicted via Artificial Neural Networks algorithm. Regardless of loading direction, the results presented a noteworthy load-bearing capability and stiffness of the atherosclerotic arteries compared to the healthy ones (P < 0.005). Theoretical fiber angles were found to be consistent with the experimental histological data with less than 2 and 5° difference for the healthy and atherosclerotic arterial walls, respectively. The pseudoelastic damage model data were also compared with that of the experimental data, and interestingly, the arterial mechanical behavior for both the primary loading (up to the elastic region) and the discontinuous softening (up to the ultimate stress) was well addressed. The proposed model predicted well the mechanical response of the arterial tissue considering the damage of collagen fibers for both the healthy and atherosclerotic arterial walls.
Collapse
Affiliation(s)
- Alireza Karimi
- Tissue Engineering and Biological Systems Research Laboratory, School of Mechanical Engineering, Iran University of Science and Technology.,Basir Eye Health Research Center, Tehran, Iran
| | | | - Toshihiro Sera
- Department of Mechanical Engineering, Kyushu University, Nishi-ku, Fukuoka, Japan
| | - Susumu Kudo
- Department of Mechanical Engineering, Kyushu University, Nishi-ku, Fukuoka, Japan
| | - Mahdi Navidbakhsh
- Tissue Engineering and Biological Systems Research Laboratory, School of Mechanical Engineering, Iran University of Science and Technology
| |
Collapse
|
11
|
Viscoelastic properties of the autologous bypass grafts: A comparative study among the small saphenous vein and internal thoracic artery. Artery Res 2017. [DOI: 10.1016/j.artres.2017.06.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
12
|
Karimi A, Shojaei A, Razaghi R. Viscoelastic mechanical measurement of the healthy and atherosclerotic human coronary arteries using DIC technique. Artery Res 2017. [DOI: 10.1016/j.artres.2017.02.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
13
|
A computational fluid-structure interaction model to predict the biomechanical properties of the artificial functionally graded aorta. Biosci Rep 2016; 36:BSR20160468. [PMID: 27836981 PMCID: PMC5180251 DOI: 10.1042/bsr20160468] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 11/09/2016] [Accepted: 11/11/2016] [Indexed: 11/17/2022] Open
Abstract
In the present study, three layers of the ascending aorta in respect to the time and space at various blood pressures have been simulated. Two well-known commercial finite element (FE) software have used to be able to provide a range of reliable numerical results while independent on the software type. The radial displacement compared with the time as well as the peripheral stress and von Mises stress of the aorta have calculated. The aorta model was validated using the differential quadrature method (DQM) solution and, then, in order to design functionally graded materials (FGMs) with different heterogeneous indexes for the artificial vessel, two different materials have been employed. Fluid-structure interaction (FSI) simulation has been carried out on the FGM and a natural vessel of the human body. The heterogeneous index defines the variation of the length in a function. The blood pressure was considered to be a function of both the time and location. Finally, the response characteristics of functionally graded biomaterials (FGBMs) models with different values of heterogeneous material parameters were determined and compared with the behaviour of a natural vessel. The results showed a very good agreement between the numerical findings of the FGM materials and that of the natural vessel. The findings of the present study may have implications not only to understand the performance of different FGMs in bearing the stress and deformation in comparison with the natural human vessels, but also to provide information for the biomaterials expert to be able to select a suitable material as an implant for the aorta.
Collapse
|
14
|
Experimental verification of the healthy and atherosclerotic coronary arteries incompressibility via Digital Image Correlation. Artery Res 2016. [DOI: 10.1016/j.artres.2016.08.002] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
15
|
Measurement of the mechanical properties of the handball, volleyball, and basketball using DIC method: a combination of experimental, constitutive, and viscoelastic models. SPORT SCIENCES FOR HEALTH 2015. [DOI: 10.1007/s11332-015-0240-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|