• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4593338)   Today's Articles (0)   Subscriber (49321)
For: Bone MC, Cunningham JL, Lord J, Giddins G, Field J, Joyce TJ. Analysis of failed Van Straten LPM proximal interphalangeal prostheses. J Hand Surg Eur Vol 2013;38:313-20. [PMID: 22989733 DOI: 10.1177/1753193412460627] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Number Cited by Other Article(s)
1
Bone MC, Naylor A. Failure of an ACCIS metal-on-metal hip resurfacing prosthesis: A case report. Proc Inst Mech Eng H 2017;231:1188-1194. [PMID: 29105561 DOI: 10.1177/0954411917737457] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
2
Rijnja JP, Kouwenberg PPGM, Ray S, Walbeehm ET. Robert Mathys Finger prosthesis of the proximal interphalangeal joint: a retrospective case series of 19 joints in 17 patients. Arch Orthop Trauma Surg 2017;137:1155-1160. [PMID: 28608275 DOI: 10.1007/s00402-017-2725-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2016] [Indexed: 11/28/2022]
3
Thorkildsen R, Reigstad O, Røkkum M. Chrome nitride coating reduces wear of small, spherical CrCoMo metal-on-metal articulations in a joint simulator. J Hand Surg Eur Vol 2017;42:310-315. [PMID: 28196445 DOI: 10.1177/1753193416674161] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
4
Joyce TJ. The design and development of a finger joint simulator. Proc Inst Mech Eng H 2016;230:450-7. [DOI: 10.1177/0954411915626943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Accepted: 12/21/2015] [Indexed: 11/15/2022]
5
In Vitro Wear Testing of a CoCr-UHMWPE Finger Prosthesis with Hydroxyapatite Coated CoCr Stems. LUBRICANTS 2015. [DOI: 10.3390/lubricants3020244] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
6
Bone MC, Giddins G, Joyce TJ. An analysis of explanted pyrolytic carbon prostheses. J Hand Surg Eur Vol 2014;39:666-7. [PMID: 23212984 DOI: 10.1177/1753193412469134] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA