1
|
Kim JS, Kim YJ, Shin YS, Ahn S, Kim WY. Use of Coronary CT Angiography to Predict Obstructive Lesions in Patients with Chest Pain without Enzyme and ST-Segment Elevation. J Clin Med 2021; 10:5442. [PMID: 34830723 PMCID: PMC8625085 DOI: 10.3390/jcm10225442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Revised: 11/18/2021] [Accepted: 11/19/2021] [Indexed: 11/17/2022] Open
Abstract
It is challenging to rule out acute coronary syndrome among chest pain patients without both ST-segment elevation in electrocardiography and troponin elevation at emergency departments (ED). The purpose of this study was to develop a prediction model for rapidly determining the occurrence of significant stenosis in coronary computed tomography angiography (CCTA). Retrospective observational cohort study was conducted with 904 patients who had presented with chest pain without troponin elevation and ST-segment changes and underwent CCTA between January 2017 and December 2018. The primary endpoint was the presence of significant stenosis on CCTA, defined as narrowing above 70% diameter. The logistic regression model was used for development a new predictive model. One hundred and thirty-four patients (14.8%) were shown severe stenosis. The independent associated factors for significant stenosis were age ≥65 years, male, diabetes, history of acute coronary syndrome, and typical chest pain. Based these results, we developed a new prediction model. The area under the curve was 0.782 (95% confidence interval 0.742-0.822). Moreover, score of ≥5 was chosen as cut-off values with 86.6% sensitivity and 56.4% specificity. In conclusion, among chest pain patients without ST changes and troponin elevation, the new score will be helpful to identify potential candidate for CCTA such as patients with significant stenosis.
Collapse
Affiliation(s)
| | | | | | | | - Won Young Kim
- Department of Emergency Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505, Korea; (J.-s.K.); (Y.-J.K.); (Y.S.S.); (S.A.)
| |
Collapse
|
2
|
Harley K, Bissonnette S, Inzitari R, Schulz K, Apple FS, Kavsak PA, Gunsolus IL. Independent and combined effects of biotin and hemolysis on high-sensitivity cardiac troponin assays. Clin Chem Lab Med 2021; 59:1431-1443. [PMID: 33761581 DOI: 10.1515/cclm-2021-0124] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 03/16/2021] [Indexed: 12/27/2022]
Abstract
OBJECTIVES This study compared the independent and combined effects of hemolysis and biotin on cardiac troponin measurements across nine high-sensitivity cardiac troponin (hs-cTn) assays. METHODS Parallel cTn measurements were made in pooled lithium heparin plasma spiked with hemolysate and/or biotin using nine hs-cTn assays: Abbott Alinity, Abbott ARCHITECT i2000, Beckman Access 2, Ortho VITROS XT 7600, Siemens Atellica, Siemens Centaur, Siemens Dimension EXL cTnI, and two Roche Cobas e 411 Elecsys Troponin T-hs cTnT assays (outside US versions, with and without increased biotin tolerance). Absolute and percent cTn recovery relative to two baseline concentrations were determined in spiked samples and compared to manufacturer's claims. RESULTS All assays except the Ortho VITROS XT 7600 showed hemolysis and biotin interference thresholds equivalent to or greater than manufacturer's claims. While imprecision confounded analysis of Ortho VITROS XT 7600 data, evidence of biotin interference was lacking. Increasing biotin concentration led to decreasing cTn recovery in three assays, specifically both Roche Cobas e 411 Elecsys Troponin T-hs assays and the Siemens Dimension EXL. While one of the Roche assays was the most susceptible to biotin among the nine studied, a new version showed reduced biotin interference by approximately 100-fold compared to its predecessor. Increasing hemolysis also generally led to decreasing cTn recovery for susceptible assays, specifically the Beckman Access 2, Ortho VITROS XT 7600, and both Roche Cobas e 411 Elecsys assays. Equivalent biotin and hemolysis interference thresholds were observed at the two cTn concentrations considered for all but two assays (Beckman Access 2 and Ortho VITROS XT 7600). When biotin and hemolysis were present in combination, biotin interference thresholds decreased with increasing hemolysis for two susceptible assays (Roche Cobas e 411 Elecsys and Siemens Dimension EXL). CONCLUSIONS Both Roche Cobas e 411 Elecsys as well as Ortho VITROS XT assays were susceptible to interference from in vitro hemolysis at levels routinely encountered in clinical laboratory samples (0-3 g/L free hemoglobin), leading to falsely low cTn recovery up to 3 ng/L or 13%. While most assays are not susceptible to biotin at levels expected with over-the-counter supplementation, severely reduced cTn recovery is possible at biotin levels of 10-2000 ng/mL (41-8,180 nmol/L) for some assays. Due to potential additive effects, analytical interferences should not be considered in isolation.
Collapse
Affiliation(s)
| | - Sarah Bissonnette
- Department of Pathology, Marshfield Clinic Health System, Marshfield, WI, USA
| | - Rosanna Inzitari
- University College Dublin School of Medicine, Clinical Research Centre, Dublin, Ireland
| | - Karen Schulz
- Hennepin Healthcare Research Institute, Hennepin County Medical Center, Minneapolis, MN, USA
| | - Fred S Apple
- Departments of Laboratory Medicine & Pathology, Hennepin Healthcare/Hennepin County Medical Center, Hennepin Healthcare Research Institute and University of Minnesota, Minneapolis, MN, USA
| | - Peter A Kavsak
- Department of Pathology and Molecular Medicine, McMaster University, Hamilton, ON, Canada
| | - Ian L Gunsolus
- Department of Pathology, Medical College of Wisconsin, 8701 W Watertown Plank Road, Milwaukee, WI, 53226, USA
| |
Collapse
|
3
|
Short-term prognosis of unstable angina in the era of high-sensitivity cardiac troponin: insights for early rule-out strategies. Coron Artery Dis 2020; 31:687-693. [PMID: 32398574 DOI: 10.1097/mca.0000000000000906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND It is unclear if strategies to rule-out myocardial infarction (MI) based on a single high-sensitivity troponin T (hsTnT) measurement at the emergency department (ED) presentation may also exclude unstable angina. METHODS We measured hsTnT ex-post on the admission frozen blood sample of 644 subjects with Braunwald IIIB CK-MB-negative unstable angina. This analysis included the 240 patients with hsTnT value ≤99th percentile reference limit (UA). We evaluated the clinical outcome of UA patients and the applicability of two rule-out strategies based on the combination of a non-ischemic ECG with (1) a single hsTnT value below the Limit-of-Detection (LoD), (2) a TIMI risk score ≤1. RESULTS UA patients with hsTnT ≤99th percentile reference limit had a favorable 30-day outcome [0.8% MI, 0% cardiovascular death (CVD)], but the rate of CVD/MI at 180-day was 4.7%. Sensitivities for UA were 94.6% according to the 'TIMI ≤1-strategy' and 75.4% according to 'hsTnT-below-LoD-strategy', accounting for 5.4 and 24.6% missed diagnoses, respectively. A prognostic risk stratification to guide appropriate outpatient assessment in potential discharged unrecognized UA patients was developed: a risk score based on the combination of age >60 years and C-reactive protein >4.5 mg/L effectively stratified the 180-day CVD/MI occurrence: 0, 2.5 and 12.7% for score 0, 1 and 2 (log-rank = 0.001, C-statistic = 0.776). CONCLUSION Single measurement hsTnT strategies, successfully tested to rule-out MI, may allow safe ED discharge of patients with a suspected acute coronary syndrome: even if UA may not be excluded, its short-term prognosis is favorable. UA patients with a C-reactive protein >4.5 mg/L and older than 60 years have a substantial medium-term cardiovascular risk and may benefit from a timely outpatient diagnostic assessment.
Collapse
|
4
|
Stepinska J, Lettino M, Ahrens I, Bueno H, Garcia-Castrillo L, Khoury A, Lancellotti P, Mueller C, Muenzel T, Oleksiak A, Petrino R, Guimenez MR, Zahger D, Vrints CJ, Halvorsen S, de Maria E, Lip GY, Rossini R, Claeys M, Huber K. Diagnosis and risk stratification of chest pain patients in the emergency department: focus on acute coronary syndromes. A position paper of the Acute Cardiovascular Care Association. EUROPEAN HEART JOURNAL. ACUTE CARDIOVASCULAR CARE 2020; 9:76-89. [PMID: 31958018 DOI: 10.1177/2048872619885346] [Citation(s) in RCA: 91] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
This paper provides an update on the European Society of Cardiology task force report on the management of chest pain. Its main purpose is to provide an update on the decision algorithms and diagnostic pathways to be used in the emergency department for the assessment and triage of patients with chest pain symptoms suggestive of acute coronary syndromes.
Collapse
Affiliation(s)
- Janina Stepinska
- Department of Intensive Cardiac Therapy, Institute of Cardiology, Poland
| | | | - Ingo Ahrens
- Department of Cardiology and Medical Intensive Care, Augustinerinnen Hospital, Germany
| | - Hector Bueno
- Cardiology Department, Hospital Universitario 12 de Octubre and Instituto de Investigación Sanitaria Hospital 12 de Octubre (imas12), Madrid, Spain and Centro Nacional de Investigaciones Cardiovasculares (CNIC), Spain
| | | | - Abdo Khoury
- Department of Emergency Medicine and Critical Care Clinical Investigation Center, University Hospital of Besançon, France
| | | | - Christian Mueller
- Cardiovascular Research Institute, University Hospital of Basel, Switzerland
| | - Thomas Muenzel
- Universitätsmedizin Mainz, Zentrum für Kardiologie, Germany
| | - Anna Oleksiak
- Department of Intensive Cardiac Therapy, Institute of Cardiology, Poland
| | | | | | - Doron Zahger
- Department of Cardiology, Soroka University Medical Center, Israel
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Than MP, Pickering JW, Sandoval Y, Shah AS, Tsanas A, Apple FS, Blankenberg S, Cullen L, Mueller C, Neumann JT, Twerenbold R, Westermann D, Beshiri A, Mills NL. Machine Learning to Predict the Likelihood of Acute Myocardial Infarction. Circulation 2019; 140:899-909. [PMID: 31416346 PMCID: PMC6749969 DOI: 10.1161/circulationaha.119.041980] [Citation(s) in RCA: 129] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2019] [Accepted: 08/09/2019] [Indexed: 12/13/2022]
Abstract
BACKGROUND Variations in cardiac troponin concentrations by age, sex, and time between samples in patients with suspected myocardial infarction are not currently accounted for in diagnostic approaches. We aimed to combine these variables through machine learning to improve the assessment of risk for individual patients. METHODS A machine learning algorithm (myocardial-ischemic-injury-index [MI3]) incorporating age, sex, and paired high-sensitivity cardiac troponin I concentrations, was trained on 3013 patients and tested on 7998 patients with suspected myocardial infarction. MI3 uses gradient boosting to compute a value (0-100) reflecting an individual's likelihood of a diagnosis of type 1 myocardial infarction and estimates the sensitivity, negative predictive value, specificity and positive predictive value for that individual. Assessment was by calibration and area under the receiver operating characteristic curve. Secondary analysis evaluated example MI3 thresholds from the training set that identified patients as low risk (99% sensitivity) and high risk (75% positive predictive value), and performance at these thresholds was compared in the test set to the 99th percentile and European Society of Cardiology rule-out pathways. RESULTS Myocardial infarction occurred in 404 (13.4%) patients in the training set and 849 (10.6%) patients in the test set. MI3 was well calibrated with a very high area under the receiver operating characteristic curve of 0.963 [0.956-0.971] in the test set and similar performance in early and late presenters. Example MI3 thresholds identifying low- and high-risk patients in the training set were 1.6 and 49.7, respectively. In the test set, MI3 values were <1.6 in 69.5% with a negative predictive value of 99.7% (99.5-99.8%) and sensitivity of 97.8% (96.7-98.7%), and were ≥49.7 in 10.6% with a positive predictive value of 71.8% (68.9-75.0%) and specificity of 96.7% (96.3-97.1%). Using these thresholds, MI3 performed better than the European Society of Cardiology 0/3-hour pathway (sensitivity, 82.5% [74.5-88.8%]; specificity, 92.2% [90.7-93.5%]) and the 99th percentile at any time point (sensitivity, 89.6% [87.4-91.6%]); specificity, 89.3% [88.6-90.0%]). CONCLUSIONS Using machine learning, MI3 provides an individualized and objective assessment of the likelihood of myocardial infarction, which can be used to identify low- and high-risk patients who may benefit from earlier clinical decisions. CLINICAL TRIAL REGISTRATION URL: https://www.anzctr.org.au. Unique identifier: ACTRN12616001441404.
Collapse
Affiliation(s)
- Martin P. Than
- Emergency Department, Christchurch Hospital, New Zealand (M.P.T., J.W.P.)
| | - John W. Pickering
- Emergency Department, Christchurch Hospital, New Zealand (M.P.T., J.W.P.)
- Christchurch Heart Institute, Department of Medicine, University of Otago, New Zealand (J.W.P.)
| | - Yader Sandoval
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (Y.S.)
| | - Anoop S.V. Shah
- British Heart Foundation Centre for Cardiovascular Sciences (A.S.V.S., N.L.M.), University of Edinburgh, United Kingdom
- Usher Institute (A.S.V.S., A.T., N.L.M.), University of Edinburgh, United Kingdom
| | - Athanasios Tsanas
- Usher Institute (A.S.V.S., A.T., N.L.M.), University of Edinburgh, United Kingdom
| | - Fred S. Apple
- Department of Laboratory Medicine & Pathology, Hennepin Healthcare/Hennepin County Medical Center and University of Minnesota, Minneapolis (F.S.A.)
| | - Stefan Blankenberg
- German Center for Cardiovascular Research (DZHK) Partner Site Hamburg. Kiel.Lu.beck (S.B., J.T.N., D.W.)
| | - Louise Cullen
- Emergency Department, Royal Brisbane and Women’s Hospital, Australia (L.C.)
| | | | - Johannes T. Neumann
- German Center for Cardiovascular Research (DZHK) Partner Site Hamburg. Kiel.Lu.beck (S.B., J.T.N., D.W.)
| | - Raphael Twerenbold
- Emergency Department, Christchurch Hospital, New Zealand (M.P.T., J.W.P.)
- Christchurch Heart Institute, Department of Medicine, University of Otago, New Zealand (J.W.P.)
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (Y.S.)
- British Heart Foundation Centre for Cardiovascular Sciences (A.S.V.S., N.L.M.), University of Edinburgh, United Kingdom
- Usher Institute (A.S.V.S., A.T., N.L.M.), University of Edinburgh, United Kingdom
- Department of Laboratory Medicine & Pathology, Hennepin Healthcare/Hennepin County Medical Center and University of Minnesota, Minneapolis (F.S.A.)
- German Center for Cardiovascular Research (DZHK) Partner Site Hamburg. Kiel.Lu.beck (S.B., J.T.N., D.W.)
- Emergency Department, Royal Brisbane and Women’s Hospital, Australia (L.C.)
- Universitatsspital Basel, Switzerland (C.M.)
- Abbott Diagnostics, Abbott Laboratories, Lake Forest, IL (A.B.)
| | - Dirk Westermann
- German Center for Cardiovascular Research (DZHK) Partner Site Hamburg. Kiel.Lu.beck (S.B., J.T.N., D.W.)
| | - Agim Beshiri
- Abbott Diagnostics, Abbott Laboratories, Lake Forest, IL (A.B.)
| | - Nicholas L. Mills
- British Heart Foundation Centre for Cardiovascular Sciences (A.S.V.S., N.L.M.), University of Edinburgh, United Kingdom
- Usher Institute (A.S.V.S., A.T., N.L.M.), University of Edinburgh, United Kingdom
| |
Collapse
|
6
|
Andruchow JE, Boyne T, Innes G, Vatanpour S, Seiden-Long I, Wang D, Lang E, McRae AD. Low High-Sensitivity Troponin Thresholds Identify Low-Risk Patients With Chest Pain Unlikely to Benefit From Further Risk Stratification. CJC Open 2019; 1:289-296. [PMID: 32159123 PMCID: PMC7063640 DOI: 10.1016/j.cjco.2019.08.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Accepted: 08/20/2019] [Indexed: 01/20/2023] Open
Abstract
Background Very low high-sensitivity cardiac troponin T (hs-cTnT) thresholds on presentation can rule out acute myocardial infarction (AMI), but the ability to identify patients at low risk of 30-day major adverse cardiac events (MACE) is less clear. This study examines the sensitivity of low concentrations of hs-cTnT on presentation to rule out 30-day MACE. Methods This prospective cohort study enrolled patients with chest pain presenting to the emergency department with nonischemic electrocardiograms who underwent AMI rule-out with an hs-cTnT assay. The primary outcome was 30-day MACE; secondary outcomes were individual MACE components. Because guidelines recommend using a single hs-cTnT strategy only for patients with more than 3 hours since symptom onset, a subgroup analysis was performed for this population. Outcomes were adjudicated on the basis of review of medical records and telephone follow-up. Results Of 1167 patients enrolled, 125 (10.7%) experienced 30-day MACE and 97 (8.3%) had AMI on the index visit. More than one-third of patients (35.6%) had presenting hs-cTnT concentrations below the limit of detection (5 ng/L), which was 94.4% (95% confidence interval [CI], 88.8-97.7) sensitive for 30-day MACE and 99.0% (95% CI, 94.5-100) sensitive for index AMI. Of 292 patients (25.0%) with hs-cTnT < 5 ng/L and at least 3 hours since symptom onset, only 3 experienced 30-day MACE (sensitivity 97.6%; 95% CI, 93.2-100) and none had AMI within 30 days (sensitivity 100%; 95% CI, 96.3-100). Conclusions Among patients with nonischemic electrocardiograms and > 3 hours since symptom onset, low hs-cTnT thresholds on presentation confer a very low risk of 30-day MACE. In the absence of a high-risk clinical presentation, further risk stratification is likely to be low yield.
Collapse
Affiliation(s)
- James E Andruchow
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Timothy Boyne
- Department of Cardiac Sciences, University of Calgary, Calgary, Alberta, Canada
| | - Grant Innes
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada.,Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
| | - Shabnam Vatanpour
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Isolde Seiden-Long
- Department of Pathology and Laboratory Medicine, University of Calgary and Alberta Public Laboratories, Calgary, Alberta, Canada
| | - Dongmei Wang
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Eddy Lang
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada.,Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
| | - Andrew D McRae
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada.,Department of Community Health Sciences, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
7
|
Li XS, Obeid S, Wang Z, Hazen BJ, Li L, Wu Y, Hurd AG, Gu X, Pratt A, Levison BS, Chung YM, Nissen SE, Tang WHW, Mach F, Räber L, Nanchen D, Matter CM, Lüscher TF, Hazen SL. Trimethyllysine, a trimethylamine N-oxide precursor, provides near- and long-term prognostic value in patients presenting with acute coronary syndromes. Eur Heart J 2019; 40:2700-2709. [PMID: 31049589 PMCID: PMC7963132 DOI: 10.1093/eurheartj/ehz259] [Citation(s) in RCA: 68] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 01/04/2019] [Accepted: 04/17/2019] [Indexed: 12/19/2022] Open
Abstract
AIMS Trimethyllysine (TML) serves as a nutrient precursor of the gut microbiota-derived metabolite trimethylamine N-oxide (TMAO) and is associated with incident cardiovascular (CV) events in stable subjects. We examined the relationship between plasma TML levels and incident CV events in patients presenting with acute coronary syndromes (ACS). METHODS AND RESULTS Plasma levels of TML were quantified in two independent cohorts using mass spectrometry, and its relationship with CV events was investigated. In a Cleveland Cohort (N = 530), comprised of patients presenting to the emergency department with chest pain and suspected ACS, TML was associated with major adverse cardiac events (MACE, myocardial infarction, stroke, need for revascularization, or all-cause mortality) over both 30 days [3rd tertile (T3), adjusted odds ratio (OR) 1.77, 95% confidence interval (CI) 1.04-3.01; P < 0.05] and 6 months (T3, adjusted OR 1.95, 95% CI 1.15-3.32; P < 0.05) of follow-up independent of traditional CV risk factors and indices of renal function. Elevated TML levels were also associated with incident long-term (7-year) all-cause mortality [T3, adjusted hazard ratio (HR) 2.52, 95% CI 1.50-4.24; P < 0.001], and MACE even amongst patients persistently negative for cardiac Troponin T at presentation (e.g. 30-day MACE, T3, adjusted OR 4.49, 95% CI 2.06-9.79; P < 0.001). Trimethyllysine in combination with TMAO showed additive significance for near- and long-term CV events, including patients with 'negative' high-sensitivity Troponin T levels. In a multicentre Swiss Cohort (N = 1683) comprised of ACS patients, similar associations between TML and incident 1-year adverse cardiac risks were observed (e.g. mortality, adjusted T3 HR 2.74, 95% CI 1.28-5.85; P < 0.05; and MACE, adjusted T3 HR 1.55, 95% CI 1.04-2.31; P < 0.05). CONCLUSION Plasma TML levels, alone and together with TMAO, are associated with both near- and long-term CV events in patients with chest pain and ACS.
Collapse
Affiliation(s)
- Xinmin S Li
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Slayman Obeid
- Department of Cardiology, University Heart Center, University Hospital Zurich, Ramistrasse 100, CH-8091, Zurich, Switzerland
| | - Zeneng Wang
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Benjamin J Hazen
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Lin Li
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Yuping Wu
- Department of Mathematics, Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115, USA
| | - Alex G Hurd
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Xiaodong Gu
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Alan Pratt
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Bruce S Levison
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Yoon-Mi Chung
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Steven E Nissen
- Department of Cardiovascular Medicine, Heart and Vascular Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - Wai Hong Wilson Tang
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
- Department of Cardiovascular Medicine, Heart and Vascular Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | - François Mach
- Department of Cardiology, Hospital Universitaire de Geneve, Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1211, Geneva 14, Switzerland
| | - Lorenz Räber
- Department of Cardiology, Swiss Heart Center, Inselspital, Freiburgstrasse 18, CH-3010, Bern, Switzerland
| | - David Nanchen
- Center for Primary Care and Public Health (Unisanté), University of Lausanne, Rue du Bugnon 44, CH-1011, Lausanne, Switzerland
| | - Christian M Matter
- Department of Cardiology, University Heart Center, University Hospital Zurich, Ramistrasse 100, CH-8091, Zurich, Switzerland
- Center for Molecular Cardiology, University of Zurich, Wagistrasse 12, CH-8952, Schlieren, Switzerland
| | - Thomas F Lüscher
- Center for Molecular Cardiology, University of Zurich, Wagistrasse 12, CH-8952, Schlieren, Switzerland
- Department of Cardiology, Royal Brompton and Harefield Hospitals, Imperial College, London, SW3 6NP, UK
| | - Stanley L Hazen
- Department of Cardiovascular and Metabolic Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
- Department of Cardiovascular Medicine, Heart and Vascular Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| |
Collapse
|
8
|
Ljung L, Reichard C, Hagerman P, Eggers KM, Frick M, Lindahl B, Linder R, Martinsson A, Melki D, Svensson P, Jernberg T. Sensitivity of undetectable level of high-sensitivity troponin T at presentation in a large non-ST-segment elevation myocardial infarction cohort of early presenters. Int J Cardiol 2019; 284:6-11. [DOI: 10.1016/j.ijcard.2018.10.088] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 09/26/2018] [Accepted: 10/25/2018] [Indexed: 11/26/2022]
|
9
|
Experiences of a One-hour Algorithm in Chest Pain Patients With a Nonelevated Troponin T at Presentation. Crit Pathw Cardiol 2019; 17:6-12. [PMID: 29432370 PMCID: PMC7654725 DOI: 10.1097/hpc.0000000000000138] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Supplemental Digital Content is available in the text. Background: We aimed to evaluate the use of a 1-hour measurement of high-sensitivity cardiac troponin T (hs-cTnT) in an emergency department (ED) population of chest pain patients with a nonelevated baseline hs-cTnT and to examine the prevalence of early dynamic changes in hs-cTnT and the association with admission rate, diagnosis, and outcome. Methods: All patients with a chief complaint of chest pain presenting to the ED of Karolinska University Hospital, Solna, Sweden, from December 2014 to September 2015 who had a baseline hs-cTnT of ≤14 ng/L and a second value obtained within >30 to ≤90 minutes were followed for 30 days regarding admission, readmission, myocardial infarction (MI), and death. Results: A total of 1091 patients were included. Dynamic 1-hour changes in hs-cTnT defined as an increase or decrease of ≥3 ng/L occurred in 23 patients (2.1%). Fifteen patients (65.2%) in the dynamic group were admitted, compared with 148 patients (13.9%) in the nondynamic group (P < 0.001). Four of the admitted patients (26.7%) in the dynamic and 1 (0.7%) in the nondynamic group were diagnosed with an MI (P < 0.001). No death or MI occurred within 30 days among those discharged from the ED. Conclusions: Dynamic 1-hour changes in hs-cTnT were uncommon but associated with a higher rate of admission and of MI in an unselected population of chest pain patients with a nonelevated hs-cTnT at presentation. Lack of dynamic changes makes MI highly unlikely, and a 1-hour measurement may facilitate an early rule out of MI but should be used together with clinical assessment.
Collapse
|
10
|
Narayanan MA, Garcia S. Role of High-sensitivity Cardiac Troponin in Acute Coronary Syndrome. US CARDIOLOGY REVIEW 2019; 13:5-10. [DOI: 10.15420/usc.2018.16.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Chest pain is one of the most common reasons for an emergency room (ER) visit in the US, with almost 6 million ER visits annually. High-sensitivity cardiac troponin (hscTn) assays have the ability to rapidly rule in or rule out acute coronary syndrome with improved sensitivity, and they are increasingly being used. Though hscTn assays have been approved for use in European, Australian, and Canadian guidelines since 2010, the FDA only approved their use in 2017. There is no consensus on how to compare the results from various hscTn assays. A literature review was performed to analyze the advantages and limitations of using hscTn as a standard biomarker to evaluate patients with suspected ACS in the emergency setting.
Collapse
Affiliation(s)
- Mahesh Anantha Narayanan
- Division of Cardiovascular Disease, Department of Medicine, University of Minnesota, Minneapolis, MN
| | - Santiago Garcia
- Minneapolis Heart Institute at Abbott Northwestern Hospital, Minneapolis, MN
| |
Collapse
|
11
|
Arslan M, Dedic A, Boersma E, Dubois EA. Serial high-sensitivity cardiac troponin T measurements to rule out acute myocardial infarction and a single high baseline measurement for swift rule-in: A systematic review and meta-analysis. EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE 2019; 9:14-22. [PMID: 30618277 PMCID: PMC7008551 DOI: 10.1177/2048872618819421] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Aims: The purpose of this study was to determine (a) the ability of serial high-sensitivity cardiac troponin T measurements to rule out acute myocardial infarction and (b) the ability of a single high baseline high-sensitivity cardiac troponin T measurement to rule in acute myocardial infarction in patients presenting to the emergency department with acute chest pain. Methods and results: Embase, Medline, Cochrane, Web of Science and Google scholar were searched for prospective cohort studies that evaluated parameters of diagnostic accuracy of serial high-sensitivity cardiac troponin T to rule out acute myocardial infarction and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction. The search yielded 21 studies for the systematic review, of which 14 were included in the meta-analysis, with a total of 11,929 patients and an overall prevalence of acute myocardial infarction of 13.0%. For rule-out, six studies presented the sensitivity of serial measurements <14 ng/l. This cut-off classified 60.1% of patients as rule-out and the summary sensitivity was 96.7% (95% confidence interval: 92.3–99.3). Three studies presented the sensitivity of a one-hour algorithm with a baseline high-sensitivity cardiac troponin T value<12 ng/l and delta 1 hour <3 ng/l. This algorithm classified 60.2% of patients as rule-out and the summary sensitivity was 98.9% (96.4–100). For rule-in, six studies reported the specificity of baseline high-sensitivity cardiac troponin T value>50 ng/l. The summary specificity was 94.6% (91.5–97.1). Conclusion: Serial high-sensitivity cardiac troponin T measurement strategies to rule out acute myocardial infarction perform well, and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction has a high specificity.
Collapse
Affiliation(s)
- M Arslan
- Department of Cardiology, Erasmus Medical Centre, The Netherlands
| | - A Dedic
- Department of Cardiology, Erasmus Medical Centre, The Netherlands
| | - E Boersma
- Department of Cardiology, Erasmus Medical Centre, The Netherlands.,Department of Clinical Epidemiology, Erasmus Medical Centre, The Netherlands
| | - E A Dubois
- Department of Cardiology, Erasmus Medical Centre, The Netherlands
| |
Collapse
|
12
|
Hof D, von Eckardstein A. High-Sensitivity Troponin Assays in Clinical Diagnostics of Acute Coronary Syndrome. Methods Mol Biol 2019; 1929:645-662. [PMID: 30710302 DOI: 10.1007/978-1-4939-9030-6_40] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Nowadays, measurement of cardiac troponins (cTn) in patient plasma is central for diagnosis of patients with acute coronary syndrome (ACS). High-sensitivity (hs) immunoassays have been developed that can very precisely record slightly elevated and rising plasma concentrations of cTn very early after onset of clinical symptoms. Algorithms integrate measurements of hs-cTn at onset of clinical symptoms of acute myocardial infarction (AMI), and 1 or 3 h after onset, to rule-in and rule-out AMI patients. More and more point-of-care (POC) cTn assays conquer the diagnostic market, but thorough clinical validation studies are required before potential implementation of such POC tests into hospital settings. This review provides an overview of the technical aspects, as well as diagnostic and prognostic use of cardiac troponins in AMI patients and in the healthy population.
Collapse
|
13
|
Eggers KM, Jernberg T, Ljung L, Lindahl B. High-Sensitivity Cardiac Troponin-Based Strategies for the Assessment of Chest Pain Patients-A Review of Validation and Clinical Implementation Studies. Clin Chem 2018; 64:1572-1585. [PMID: 29941466 DOI: 10.1373/clinchem.2018.287342] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Accepted: 05/14/2018] [Indexed: 12/26/2022]
Abstract
BACKGROUND The introduction of high-sensitivity cardiac troponin (hs-cTn) assays has improved the early assessment of chest pain patients. A number of hs-cTn-based algorithms and accelerated diagnostic protocols (ADPs) have been developed and tested subsequently. In this review, we summarize the data on the performance and clinical utility of these strategies. CONTENT We reviewed studies investigating the diagnostic and prognostic performance of hs-cTn algorithms [level of detection (LoD) strategy, 0/1-h, 0/2-h, and 0/3-h algorithms) and of hs-cTn-based ADPs, together with the implications of these strategies when implemented as clinical routine. The LoD strategy, when combined with a nonischemic electrocardiogram, is best suited for safe rule-out of myocardial infarction and the identification of patients eligible for early discharge from the emergency department. The 0/1-h algorithms appear to identify most patients as being eligible for rule-out. The hs-cTn-based ADPs mainly focus on prognostic assessment, which is in contrast with the hs-cTn algorithms. They identify smaller proportions of rule-out patients, but there is increasing evidence from prospective studies on their successful clinical implementation. Such information is currently lacking for hs-cTn algorithms. CONCLUSIONS There is a trade-off between safety and efficacy for different hs-cTn-based strategies. This trade-off should be considered for the intended strategy, along with its user-friendliness and evidence from clinical implementation studies. However, several gaps in knowledge remain. At present, we suggest the use of an ADP in conjunction with serial hs-cTn results to optimize the early assessment of chest pain patients.
Collapse
Affiliation(s)
- Kai M Eggers
- Department of Medical Sciences and Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden;
| | - Tomas Jernberg
- Department of Clinical Sciences, Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden
| | - Lina Ljung
- Department of Cardiology, Södersjukhuset and Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm, Sweden
| | - Bertil Lindahl
- Department of Medical Sciences and Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden
| |
Collapse
|
14
|
Than MP, Aldous SJ, Troughton RW, Pemberton CJ, Richards AM, Frampton CMA, Florkowski CM, George PM, Bailey S, Young JM, Cullen L, Greenslade JH, Parsonage WA, Everett BM, Peacock WF, Jaffe AS, Pickering JW. Detectable High-Sensitivity Cardiac Troponin within the Population Reference Interval Conveys High 5-Year Cardiovascular Risk: An Observational Study. Clin Chem 2018; 64:1044-1053. [PMID: 29760219 DOI: 10.1373/clinchem.2017.285700] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Accepted: 04/10/2018] [Indexed: 12/31/2022]
Abstract
BACKGROUND Increased cardiac troponin I or T detected by high-sensitivity assays (hs-cTnI or hs-cTnT) confers an increased risk of adverse prognosis. We determined whether patients presenting with putatively normal, detectable cTn concentrations [> limit of detection and < upper reference limit (URL)] have increased risk of major adverse cardiovascular events (MACE) or all-cause mortality. METHODS A prospective 5-year follow-up of patients recruited in the emergency department with possible acute coronary syndrome (ACS) and cTn concentrations measured with hs-cTnI (Abbott) and hs-cTnT (Roche) assays. Cox regression models were generated with adjustment for covariates in those without MACE on presentation. Hazard ratios (HRs) for hs-cTn were calculated relative to the HRs at the median concentration. RESULTS Of 1113 patients, 836 were without presentation MACE. Of these, 138 incurred a MACE and 169 died during a median 5.8-year follow-up. HRs for MACE at the URLs were 2.3 (95% CI, 1.7-3.2) for hs-cTnI and 1.8 (95% CI, 1.3-2.4) for hs-cTnT. Corresponding HRs for mortality were 1.7 (95% CI, 1.2-2.2) for hs-cTnI and 2.3 (95 % CI, 1.7-3.1) for hs-cTnT. The HR for MACE increased with increasing hs-cTn concentration similarly for both assays, but the HR for mortality increased at approximately twice the rate for hs-cTnT than hs-cTnI. Patients with hs-cTnI ≥10 ng/L or hs-cTnT ≥16 ng/L had the same percentage of MACE at 5-year follow-up (33%) as patients with presentation MACE. CONCLUSIONS Many patients with ACS ruled out and putatively normal but detectable hs-cTnI concentrations are at similar long-term risk as those with MACE. hs-cTnT concentrations are more strongly associated with 5-year mortality than hs-cTnI.
Collapse
Affiliation(s)
| | | | - Richard W Troughton
- Christchurch Hospital, Christchurch, New Zealand.,Christchurch Heart Institute, University of Otago Christchurch, Christchurch, New Zealand
| | | | - A Mark Richards
- Christchurch Heart Institute, University of Otago Christchurch, Christchurch, New Zealand.,National University of Singapore, Singapore
| | | | | | | | | | | | - Louise Cullen
- Royal Brisbane and Women's Hospital, Herston, Australia.,University of Technology, Brisbane, Australia.,University of Queensland, Brisbane, Australia
| | - Jaimi H Greenslade
- Royal Brisbane and Women's Hospital, Herston, Australia.,University of Queensland, Brisbane, Australia
| | | | - Brendan M Everett
- Divisions of Cardiovascular and Preventive Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, MA
| | | | | | - John W Pickering
- Christchurch Hospital, Christchurch, New Zealand; .,Christchurch Heart Institute, University of Otago Christchurch, Christchurch, New Zealand
| |
Collapse
|
15
|
Andruchow JE, Kavsak PA, McRae AD. Contemporary Emergency Department Management of Patients with Chest Pain: A Concise Review and Guide for the High-Sensitivity Troponin Era. Can J Cardiol 2017; 34:98-108. [PMID: 29407013 DOI: 10.1016/j.cjca.2017.11.012] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 11/23/2017] [Accepted: 11/23/2017] [Indexed: 11/17/2022] Open
Abstract
This article synthesizes current best evidence for the evaluation of patients with suspected acute coronary syndrome (ACS) using high-sensitivity troponin assays, enabling physicians to effectively incorporate them into practice. Unlike conventional assays, high-sensitivity assays can precisely measure blood cardiac troponin concentrations in the vast majority of healthy individuals, facilitating the creation of rapid diagnostic algorithms. Very low troponin concentrations on presentation accurately rule out acute myocardial infarction (AMI) and enable the discharge of approximately 20% of patients after a single test, whereas an additional 30%-40% of patients can be safely discharged after short-interval serial sampling in as little as 1 or 2 hours. In contrast, highly abnormal troponin concentrations on presentation (more than 5 times the upper reference limit) or rapidly rising levels on serial testing can rapidly rule in AMI with high specificity. However, approximately one-third of patients remain in a biomarker-indeterminate "observation zone" even after serial sampling. These patients pose a disposition challenge to clinicians because although the differential diagnosis of elevated troponin concentrations is broad, these patients have an increased risk for short-term major adverse cardiac events. Use of repeated serial troponin sampling and structured clinical prediction tools may assist disposition for these patients, because no validated pathways currently exist to guide clinicians. Ongoing research to tailor diagnostic thresholds to individual patient characteristics may enable improved diagnostic accuracy and usher in a new era of personalized medicine in the evaluation of suspected ACS.
Collapse
Affiliation(s)
- James E Andruchow
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada; Alberta Health Services, Calgary, Alberta, Canada.
| | - Peter A Kavsak
- Department of Pathology and Molecular Medicine, McMaster University, Hamilton, Ontario, Canada
| | - Andrew D McRae
- Department of Emergency Medicine, University of Calgary, Calgary, Alberta, Canada; Alberta Health Services, Calgary, Alberta, Canada
| |
Collapse
|
16
|
Sandoval Y, Smith SW, Love SA, Sexter A, Schulz K, Apple FS. Single High-Sensitivity Cardiac Troponin I to Rule Out Acute Myocardial Infarction. Am J Med 2017; 130:1076-1083.e1. [PMID: 28344141 DOI: 10.1016/j.amjmed.2017.02.032] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 02/10/2017] [Accepted: 02/13/2017] [Indexed: 01/09/2023]
Abstract
BACKGROUND This study examined the performance of single high-sensitivity cardiac troponin I (hs-cTnI) measurement strategies to rule out acute myocardial infarction. METHODS This was a prospective, observational study of consecutive patients presenting to the emergency department (n = 1631) in whom cTnI measurements were obtained using an investigational hs-cTnI assay. The goals of the study were to determine 1) negative predictive value (NPV) and sensitivity for the diagnosis of acute myocardial infarction, type 1 myocardial infarction, and type 2 myocardial infarction; and 2) safety outcome of acute myocardial infarction or cardiac death at 30 days using hs-cTnI less than the limit of detection (LoD) (<1.9 ng/L) or the High-STEACS threshold (<5 ng/L) alone and in combination with normal electrocardiogram (ECG). RESULTS Acute myocardial infarction occurred in 170 patients (10.4%), including 68 (4.2%) type 1 myocardial infarction and 102 (6.3%) type 2 myocardial infarction. For hs-cTnI<LoD (27%), the NPV and sensitivity for acute myocardial infarction were 99.6% (95% confidence interval 98.9%-100%) and 98.8 (97.2%-100%). For hs-cTnI<5 ng/L (50%), the NPV and sensitivity for acute myocardial infarction were 98.9% (98.2%-99.6%) and 94.7% (91.3%-98.1%). In combination with a normal ECG, 1) hs-cTnI<LoD had an NPV of 99.6% (98.9%-100%) and sensitivity of 99.4% (98.3%-100%); and 2) hs-cTnI<5 ng/L had an NPV of 99.5% (98.8%-100%) and sensitivity of 98.8% (97.2%-100%). The NPV and sensitivity for the safety outcome were excellent for hs-cTnI<LoD alone or in combination with a normal ECG, and for hs-cTnI<5 ng/L in combination with a normal ECG. CONCLUSION Strategies using a single hs-cTnI alone or in combination with a normal ECG allow the immediate identification of patients unlikely to have acute myocardial infarction and who are at very low risk for adverse events at 30 days.
Collapse
Affiliation(s)
- Yader Sandoval
- Division of Cardiology, Hennepin County Medical Center and Minneapolis Heart Institute, Abbott Northwestern Hospital, Minn
| | - Stephen W Smith
- Department of Emergency Medicine, Hennepin County Medical Center and University of Minnesota, Minneapolis
| | - Sara A Love
- Minneapolis Medical Research Foundation, Minn; Department of Laboratory Medicine and Pathology, Hennepin County Medical Center and University of Minnesota, Minneapolis
| | - Anne Sexter
- Minneapolis Medical Research Foundation, Minn
| | | | - Fred S Apple
- Minneapolis Medical Research Foundation, Minn; Department of Laboratory Medicine and Pathology, Hennepin County Medical Center and University of Minnesota, Minneapolis.
| |
Collapse
|
17
|
Dynamic high-sensitivity troponin elevations in atrial fibrillation patients might not be associated with significant coronary artery disease. BMC Cardiovasc Disord 2017; 17:169. [PMID: 28655300 PMCID: PMC5488365 DOI: 10.1186/s12872-017-0601-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Accepted: 06/20/2017] [Indexed: 11/18/2022] Open
Abstract
Background Since the introduction of high-sensitivity troponin assays a greater proportion of atrial fibrillation (AF) patients present with dynamic troponin elevations. We hypothesize that significant coronary artery disease (CAD) causes relative ischemia in the setting of a rapid heart rate resulting in dynamic troponin elevation. The aim of this study was to examine if patients without known CAD who present with AF, tachycardia and dynamic high-sensitivity troponin T (hsTnT) change have an increased risk of cardiac events. Methods We retrospectively included AF patients presenting with tachycardia during one year. The primary endpoint was acute coronary syndrome, revascularization or death due to ischemic heart disease during 30 months follow-up. Results Five hundred twenty-two patients without known CAD were included, 300 (57%) had normal hsTnT and 49 (9.5%) had dynamic hsTnT elevation. During follow-up 12 (4%) patients with normal hsTnT reached the primary endpoint and a total of 14 (4.7%) patients died. In the group with dynamic hsTnT the results were 4 (8.2%) and 12 (25%) respectively. The age-adjusted hazard ratio (HR) for the primary endpoint in patients with dynamic hsTnT was 1.9 (95% CI: 0.6 to 6.2; p = 0.28) and for all-cause mortality 3.8 (95% CI: 1.7 to 8.5; p = 0.001). Conclusions Dynamic hsTnT elevation in connection with AF might not be associated with any major increased risk of coronary events, but indicates increased all-cause mortality. Electronic supplementary material The online version of this article (doi:10.1186/s12872-017-0601-7) contains supplementary material, which is available to authorized users.
Collapse
|
18
|
Mass spectrometry in medicine: a technology for the future? Future Sci OA 2017; 3:FSO213. [PMID: 28884010 PMCID: PMC5583653 DOI: 10.4155/fsoa-2017-0053] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Accepted: 04/26/2017] [Indexed: 01/01/2023] Open
|
19
|
Chapman AR, Anand A, Boeddinghaus J, Ferry AV, Sandeman D, Adamson PD, Andrews J, Tan S, Cheng SF, D'Souza M, Orme K, Strachan FE, Nestelberger T, Twerenbold R, Badertscher P, Reichlin T, Gray A, Shah ASV, Mueller C, Newby DE, Mills NL. Comparison of the Efficacy and Safety of Early Rule-Out Pathways for Acute Myocardial Infarction. Circulation 2017; 135:1586-1596. [PMID: 28034899 PMCID: PMC5404406 DOI: 10.1161/circulationaha.116.025021] [Citation(s) in RCA: 151] [Impact Index Per Article: 18.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Accepted: 12/15/2016] [Indexed: 01/25/2023]
Abstract
BACKGROUND High-sensitivity cardiac troponin assays enable myocardial infarction to be ruled out earlier, but the optimal approach is uncertain. We compared the European Society of Cardiology rule-out pathway with a pathway that incorporates lower cardiac troponin concentrations to risk stratify patients. METHODS Patients with suspected acute coronary syndrome (n=1218) underwent high-sensitivity cardiac troponin I measurement at presentation and 3 and 6 or 12 hours. We compared the European Society of Cardiology pathway (<99th centile at presentation or at 3 hours if symptoms <6 hours) with a pathway developed in the High-STEACS study (High-Sensitivity Troponin in the Evaluation of Patients With Acute Coronary Syndrome) population (<5 ng/L at presentation or change <3 ng/L and <99th centile at 3 hours). The primary outcome was a comparison of the negative predictive value of both pathways for index type 1 myocardial infarction or type 1 myocardial infarction or cardiac death at 30 days. We evaluated the primary outcome in prespecified subgroups stratified by age, sex, time of symptom onset, and known ischemic heart disease. RESULTS The primary outcome occurred in 15.7% (191 of 1218) patients. In those less than the 99th centile at presentation, the European Society of Cardiology pathway ruled out myocardial infarction in 28.1% (342 of 1218) and 78.9% (961 of 1218) at presentation and 3 hours, respectively, missing 18 index and two 30-day events (negative predictive value, 97.9%; 95% confidence interval, 96.9-98.7). The High-STEACS pathway ruled out 40.7% (496 of 1218) and 74.2% (904 of 1218) at presentation and 3 hours, missing 2 index and two 30-day events (negative predictive value, 99.5%; 95% confidence interval, 99.0-99.9; P<0.001 for comparison). The negative predictive value of the High-STEACS pathway was greater than the European Society of Cardiology pathway overall (P<0.001) and in all subgroups, including those presenting early or known to have ischemic heart disease. CONCLUSIONS Use of the High-STEACS pathway incorporating low high-sensitivity cardiac troponin concentrations rules out myocardial infarction in more patients at presentation and misses 5-fold fewer index myocardial infarctions than guideline-approved pathways based exclusively on the 99th centile. CLINICAL TRIAL REGISTRATION URL: http://clinicaltrials.gov. Unique identifier: NCT01852123.
Collapse
Affiliation(s)
- Andrew R Chapman
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom.
| | - Atul Anand
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Jasper Boeddinghaus
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Amy V Ferry
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Dennis Sandeman
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Philip D Adamson
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Jack Andrews
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Stephanie Tan
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Sheun F Cheng
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Michelle D'Souza
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Kate Orme
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Fiona E Strachan
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Thomas Nestelberger
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Raphael Twerenbold
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Patrick Badertscher
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Tobias Reichlin
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Alasdair Gray
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Anoop S V Shah
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Christian Mueller
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - David E Newby
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| | - Nicholas L Mills
- From British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (A.R.C., A.A., A.V.F., D.S., P.D.A., J.A., S.T., S.F.C., M.D., K.O., F.E.S., A.G., A.S.V.S., D.E.N., N.L.M.); Cardiovascular Research Institute Basel and Department of Cardiology, University Hospital, Switzerland (J.B., T.N., R.T., P.B.., T.R., C.M.); and Department of Emergency Medicine (A.G.) and EMERGE Research Group (A.G.), Royal Infirmary of Edinburgh, United Kingdom
| |
Collapse
|
20
|
Sandoval Y, Smith SW, Shah ASV, Anand A, Chapman AR, Love SA, Schulz K, Cao J, Mills NL, Apple FS. Rapid Rule-Out of Acute Myocardial Injury Using a Single High-Sensitivity Cardiac Troponin I Measurement. Clin Chem 2017; 63:369-376. [PMID: 27811203 DOI: 10.1373/clinchem.2016.264523] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2016] [Accepted: 08/23/2016] [Indexed: 01/07/2023]
Abstract
BACKGROUND Rapid rule-out strategies using high-sensitivity cardiac troponin assays are largely supported by studies performed outside the US in selected cohorts of patients with chest pain that are atypical of US practice, and focused exclusively on ruling out acute myocardial infarction (AMI), rather than acute myocardial injury, which is more common and associated with a poor prognosis. METHODS Prospective, observational study of consecutive patients presenting to emergency departments [derivation (n = 1647) and validation (n = 2198) cohorts], where high-sensitivity cardiac troponin I (hs-cTnI) was measured on clinical indication. The negative predictive value (NPV) and diagnostic sensitivity of an hs-cTnI concentration RESULTS In patients with hs-cTnI concentrations <99th percentile at presentation, acute myocardial injury occurred in 8.3% and 11.0% in the derivation and validation cohorts, respectively. In the derivation cohort, 27% had hs-cTnI < LoD, with NPV and diagnostic sensitivity for acute myocardial injury of 99.1% (95% CI, 97.7-99.8) and 99.0% (97.5-99.7) and an NPV for AMI or cardiac death at 30 days of 99.6% (98.4-100). In the validation cohort, 22% had hs-cTnI CONCLUSIONS A single hs-cTnI concentration
Collapse
Affiliation(s)
- Yader Sandoval
- Division of Cardiology, Hennepin County Medical Center, Minneapolis, MN
- Minneapolis Heart Institute, Abbott-Northwestern Hospital, Minneapolis, MN
- Minneapolis Medical Research Foundation, Minneapolis, MN
| | - Stephen W Smith
- Minneapolis Medical Research Foundation, Minneapolis, MN
- Department of Emergency Medicine, Hennepin County Medical Center and University of Minnesota, MN
| | - Anoop S V Shah
- BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Atul Anand
- BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Andrew R Chapman
- BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Sara A Love
- Minneapolis Medical Research Foundation, Minneapolis, MN
- Department of Laboratory Medicine and Pathology, Hennepin County Medical Center and University of Minnesota, Minneapolis, MN
| | - Karen Schulz
- Minneapolis Medical Research Foundation, Minneapolis, MN
| | - Jing Cao
- Minneapolis Medical Research Foundation, Minneapolis, MN
| | - Nicholas L Mills
- BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Fred S Apple
- Minneapolis Medical Research Foundation, Minneapolis, MN;
- Department of Laboratory Medicine and Pathology, Hennepin County Medical Center and University of Minnesota, Minneapolis, MN
| |
Collapse
|
21
|
Abstract
Acute coronary syndrome (ACS) encompasses a pathophysiological spectrum of cardiovascular diseases, all of which have significant morbidity and mortality. ACS was once considered an acute condition; however, new treatment strategies and improvements in biomarker assays have led to ACS being an acute and chronic disease. Cardiac troponin is the preferred biomarker for the diagnosis of myocardial infarction, and there is considerable interest and efforts toward development and implementation of high-sensitivity cardiac troponin (hs-cTn) assays worldwide. Analytical and clinical performance characteristics of hs-cTn assays as well as testing limitations are important for laboratorians and clinicians to understand in order to utilize testing appropriately. Furthermore, expanding the clinical utility of hs-cTn into other cohorts such as asymptomatic community dwelling populations, heart failure, and chronic kidney disease populations supports novel opportunities for improved short- and long-term prognosis.
Collapse
|
22
|
Sandoval Y, Apple FS, Smith SW. High-sensitivity cardiac troponin assays and unstable angina. EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE 2016; 7:120-128. [DOI: 10.1177/2048872616658591] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The term unstable angina has been conventionally applied to patients with myocardial ischemia without myocardial necrosis. However, while the clinical context has remained constant over time, the biomarkers of myocardial injury and acute myocardial infarction have evolved. High-sensitivity cardiac troponin assays have several key analytical differences from prior cardiac troponin assay generations, which may alter the diagnosis and frequency of unstable angina, as well as affect our understanding of previously developed risk stratification strategies. This document reviews the current challenges in regards to unstable angina when using high-sensitivity cardiac troponin I and T assays.
Collapse
Affiliation(s)
- Yader Sandoval
- Division of Cardiology, Department of Medicine, Hennepin County Medical Center, Minneapolis, MN, USA
- Minneapolis Heart Institute, Abbott-Northwestern Hospital, Minneapolis, MN, USA
| | - Fred S Apple
- Department of Laboratory Medicine and Pathology, Hennepin County Medical Center and University of Minnesota, Minneapolis, MN, USA
| | - Stephen W Smith
- Department of Emergency Medicine, Hennepin County Medical Center and University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
23
|
Sandoval Y, Smith SW, Apple FS. Present and Future of Cardiac Troponin in Clinical Practice: A Paradigm Shift to High-Sensitivity Assays. Am J Med 2016; 129:354-65. [PMID: 26743351 DOI: 10.1016/j.amjmed.2015.12.005] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2015] [Revised: 11/30/2015] [Accepted: 12/01/2015] [Indexed: 11/19/2022]
Abstract
Despite its wide utilization and central role in the evaluation of patients with potential ischemic symptoms, misconceptions and confusion about cardiac troponin (cTn) prevail. The implementation of high-sensitivity (hs) cTn assays in clinical practice has multiple potential advantages provided there is an education process tied to the introduction of these assays that emphasizes the appropriate utilization of the test. Several diagnostic strategies have been explored with hs-cTn assays, including the use of undetectable values, accelerated serial hs-cTn sampling, hs-cTn measurements in combination with a clinical-risk score, and the use of a single hs-cTn measurement with a concentration threshold tailored to meet a clinical need. In this document we discuss basic concepts that should facilitate the integration of hs-cTn assays into clinical care in years to come.
Collapse
Affiliation(s)
- Yader Sandoval
- Division of Cardiology, Department of Medicine, Hennepin County Medical Center, Minneapolis, Minn; Minneapolis Heart Institute, Abbott-Northwestern Hospital, Minn.
| | - Stephen W Smith
- Department of Emergency Medicine, Hennepin County Medical Center and University of Minnesota, Minneapolis
| | - Fred S Apple
- Department of Laboratory Medicine and Pathology, Hennepin County Medical Center and University of Minnesota, Minneapolis
| |
Collapse
|
24
|
The Correlation of Serum Myeloid-Related Protein-8/14 and Eosinophil Cationic Protein in Patients with Coronary Artery Disease. BIOMED RESEARCH INTERNATIONAL 2016; 2016:4980251. [PMID: 27022611 PMCID: PMC4789061 DOI: 10.1155/2016/4980251] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 10/22/2015] [Accepted: 12/06/2015] [Indexed: 02/06/2023]
Abstract
Objective. To investigate the changes in serum Myeloid-Related Protein 8/14 (MRP8/14) and Eosinophil Cationic Protein (ECP) levels in patients with different types of coronary artery diseases (CAD) and assess the value of MRP8/14 and ECP detection in predicting CAD. Methods. 178 patients were divided into CAD group including unstable angina pectoris (UAP), acute myocardial infarction (AMI), and stable angina pectoris (SAP). Thirty-six individuals with normal coronary artery served as the control group. Serum MRP8/14 and ECP were measured by ELISA. The severity of coronary artery stenosis was assessed by the numbers of involved coronary artery branches and the sum of Gensini scores. Results. The MRP8/14 levels were significantly higher in AMI and UAP group than SAP and control group (P < 0.05). The levels of MRP8/14 in AMI group were also obviously higher than UAP group (P < 0.05). The ECP levels were obviously increased in AMI group, but there was no difference between SAP and UAP group (P > 0.05). The ECP was significantly increased in three impaired coronary arteries and obviously correlated with Gensini score (P < 0.01), whereas the MRP8/14 was obviously positively correlated with CRP (P < 0.01). Conclusions. Increased MRP8/14 levels suggest the instability of the atherosclerotic plaque. ECP reflects the severity of coronary arteries stenosis, predicting atherosclerosis burden. They may become the new biomarkers of CAD.
Collapse
|