1
|
Cook V, Wang A, Llewellyn S, Adendorff B, Yan T. Modified Circuit for Left-Sided Heart Bypass in Thoracoabdominal Surgery. ANNALS OF THORACIC SURGERY SHORT REPORTS 2024; 2:21-24. [PMID: 39790259 PMCID: PMC11708587 DOI: 10.1016/j.atssr.2023.09.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 09/05/2023] [Indexed: 01/12/2025]
Abstract
Left-sided heart bypass may be run with a complete cardiopulmonary bypass circuit or a venoarterial extracorporeal membrane oxygenation circuit in thoracoabdominal surgery. Both configurations have specific disadvantages. We describe a modified circuit for left-sided heart bypass that can be run as an extracorporeal membrane oxygenation-like circuit, allowing lower activated clotting time targets and simplified perfusion while improving blood conservation and facilitating visceral perfusion.
Collapse
Affiliation(s)
- Victoria Cook
- Department of Cardiothoracic Surgery, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Andy Wang
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
- Sydney Medical School, Faculty of Medicine & Health, University of Sydney, Sydney, New South Wales, Australia
| | - Stephen Llewellyn
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Bruce Adendorff
- Department of Anaesthetics, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Tristan Yan
- Department of Cardiothoracic Surgery, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
- Sydney Medical School, Faculty of Medicine & Health, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
2
|
Huang L, Chen X, Hu Q, Luo F, Hu J, Duan L, Wang E, Ye Z, Zhang C. The application of modular multifunctional left heart bypass circuit system integrated with ultrafiltration in thoracoabdominal aortic aneurysm repair. Front Cardiovasc Med 2022; 9:944287. [PMID: 36211541 PMCID: PMC9534546 DOI: 10.3389/fcvm.2022.944287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Accepted: 08/23/2022] [Indexed: 11/13/2022] Open
Abstract
Open thoracoabdominal aortic aneurysm (TAAA) repair is a complex and challenging operation with a high incidence of serious complications, and high perioperative mortality and morbidity. Left heart bypass (LHB) is a circulatory support system used to perfuse the distal aorta during TAAA operation, and the advantages of LHB include guaranteeing distal perfusion, reducing the use of heparin, and diminishing the risk of bleeding and postoperative neurological deficits. In China, the circuit for TAAA repair is deficient, and far from the perfusion requirements. We designed a modular multifunctional LHB circuit for TAAA repair. The modular circuit consisted of cannulation pipelines, functional consumables connection pipelines, and accessory pipelines. The accessory pipelines make up lines for selective visceral perfusion and kidney perfusion, suckers and rapid infusion. The circuit can be assembled according to surgical requirements. The ultrafilter and heat exchanger are integrated into the circuit to fulfill the basic demands of LHB. The LHB circuit also has pipelines for selective visceral perfusion to the celiac artery and superior mesenteric artery and renal perfusion pipelines. Meanwhile, the reserved pipelines facilitate the quick switch from LHB to conventional cardiopulmonary bypass (CPB). The reserved pipelines reduce the time of reassembling the CPB circuit. Moreover, the rapid infusion was integrated into the LHB circuit, which can rapid infusion when massive hemorrhage during the open procedures such as exposure and reconstruction of the aorta. The ultrafiltration can diminish the consequent hemodilution of hemorrhage and rapid infusion. A hemoperfusion cartridge also can be added to reduce the systemic inflammatory during operation. The circuit can meet the needs of LHB and quickly switch to conventional CPB. No oxygenator was required during LHB, which reduce the use of heparin and reduce the risk of bleeding. The heat exchanger contributes to temperature regulation; ultrafiltration, arterial filter, and rapid-infusion facilitated the blood volume management and are useful to maintain hemodynamic stability. This circuit made the assembly of the LHB circuit more easily, and more efficient, which may contribute to the TAAA repair operation performed in lower volume centers easily. 26 patients who received TAAA repair under the modular multifunctional LHB from January 2018-March 2022 were analyzed, and we achieved acceptable clinical outcomes. The in-hospital mortality and 30-day postoperative mortality were 15.4%, and the postoperative incidences of paraparesis (4%), stroke (4%), and AKI need hemodialysis (12%) were not particularly high, based on the limited patients sample size in short research period duration.
Collapse
Affiliation(s)
- Lingjin Huang
- Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Xuliang Chen
- Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Qinghua Hu
- Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Fanyan Luo
- Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - Jiajia Hu
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
- Department of Anesthesiology, Xiangya Hospital, Central South University, Changsha, China
| | - Lian Duan
- Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| | - E. Wang
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
- Department of Anesthesiology, Xiangya Hospital, Central South University, Changsha, China
| | - Zhi Ye
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
- Department of Anesthesiology, Xiangya Hospital, Central South University, Changsha, China
| | - Chengliang Zhang
- Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, Changsha, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|