1
|
Swor K, Yeo L, Tarca AL, Jung E, Romero R. Fetal intelligent navigation echocardiography (FINE) has superior performance compared to manual navigation of the fetal heart by non-expert sonologists. J Perinat Med 2022; 51:477-491. [PMID: 36474319 PMCID: PMC10164033 DOI: 10.1515/jpm-2022-0387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 10/15/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVES Manual and intelligent navigation (i.e. fetal intelligent navigation echocardiography or FINE) by the operator are two methods to obtain standard fetal cardiac views from spatiotemporal image correlation (STIC) volumes. The objective was to compare the performance between manual and intelligent navigation (FINE) of the fetal heart by non-expert sonologists. METHODS In this prospective observational study, ten sonologists underwent formal training on both navigational methods. Subsequently, they were tested on their ability to obtain nine cardiac views from five STIC volumes of normal fetal hearts (19-28 gestational weeks) using such methods. The following parameters were determined for both methods: (1) success rate of obtaining nine cardiac views; (2) mean time to obtain nine cardiac views per sonologist; and (3) maximum number of cardiac views successfully obtained for each STIC volume. RESULTS All fetal cardiac images obtained from 100 STIC volumes (50 for each navigational method) were reviewed by an expert in fetal echocardiography. Compared to manual navigation, FINE was associated with a significantly: (1) higher success rate of obtaining eight (excluding the abdomen view) appropriate cardiac views (92-100% vs. 56-88%; all p<0.05); (2) shorter mean time (minute:seconds) to obtain nine cardiac views (2:11 ± 0:37 vs. 15:49 ± 7:44; p<0.0001); and (3) higher success rate of obtaining all nine cardiac views for a given STIC volume (86 vs. 14%; p<0.001). CONCLUSIONS When performed by non-expert sonologists, intelligent navigation (FINE) had a superior performance compared to manual navigation of the normal fetal heart. Specifically, FINE obtained appropriate fetal cardiac views in 92-100% of cases.
Collapse
Affiliation(s)
- Katie Swor
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Detroit Medical Center, Detroit, MI, USA.,Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Lami Yeo
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Detroit Medical Center, Detroit, MI, USA.,Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Adi L Tarca
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA.,Department of Computer Science, College of Engineering, Wayne State University, Detroit, MI, USA
| | - Eunjung Jung
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Roberto Romero
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Detroit Medical Center, Detroit, MI, USA.,Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, USA.,Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI, USA.,Center for Molecular Medicine and Genetics, Wayne State University, Detroit, MI, USA
| |
Collapse
|
2
|
Gembicki M, Hartge DR, Fernandes T, Weichert J. Feasibility of Semiautomatic Fetal Intelligent Navigation Echocardiography for Different Fetal Spine Positions: A Matter of "Time"? JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:91-100. [PMID: 32583930 DOI: 10.1002/jum.15379] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2020] [Revised: 05/11/2020] [Accepted: 05/19/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES We investigated the feasibility of a semiautomatic approach for assessments of the fetal heart (fetal intelligent navigation echocardiography [FINE]) in cases of optimal and unfavorable fetal spine positions. METHODS In this study, a total of 1693 spatiotemporal image correlation volumes of first-, second-, and third-trimester fetuses were evaluated by experts using the FINE approach. The data were analyzed regarding proper reconstruction of the diagnostic cardiac planes depending on the fetal spine position. RESULTS A total of 1531 volumes were included. The volumes were divided into 4 groups depending on the fetal spine position: 5-7 o'clock, 4 + 8 o'clock, 3 + 9 o'clock, and 2 + 10 o'clock. In total, 93.2% of the diagnostic planes were displayed properly. Between 5 and 7 o'clock, 94.9% of the diagnostic planes were displayed properly. The correct depiction rates in the other groups were 92.4% (4 + 8 o'clock; n = 538; P = 0.0027), 88.3% (3 + 9 o'clock; n = 156; P < .0001), and 87.3% (2 + 10 o'clock; n = 41; P = .0139). In total, the highest dropout rates were found in the sagittal planes: ductal arch, 13.9%; aortic arch, 10.5%; and venae cavae, 12.0%. CONCLUSIONS Based on our results, the FINE technique is an effective method, but its feasibility depends on the fetal position. The use of this semiautomatic work flow-based approach supports evaluation of the fetal heart in a standardized manner. Semiautomatic evaluation of the fetal heart might be useful in facilitating the detection of fetal cardiac anomalies.
Collapse
Affiliation(s)
- Michael Gembicki
- Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, Luebeck, Schleswig-Holstein, Germany
| | - David R Hartge
- Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, Luebeck, Schleswig-Holstein, Germany
| | - Theresa Fernandes
- Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, Luebeck, Schleswig-Holstein, Germany
| | - Jan Weichert
- Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, Luebeck, Schleswig-Holstein, Germany
| |
Collapse
|
3
|
Huang J, Shi H, Chen Q, Hu J, Zhang Y, Song H, Zhou Q. Three-Dimensional Printed Model Fabrication and Effectiveness Evaluation in Fetuses With Congenital Heart Disease or With a Normal Heart. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:15-28. [PMID: 32562576 DOI: 10.1002/jum.15366] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2020] [Revised: 05/02/2020] [Accepted: 05/14/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES The purpose of this study was to investigate the technical feasibility and accuracy of applying 3-dimensional (3D) printing of normal and abnormal fetal hearts based on spatiotemporal image correlation (STIC) volume-rendered data. METHODS Spatiotemporal image correlation volume images of 15 healthy fetuses and 15 fetuses with cardiac abnormalities were collected, and Mimics software (Materialise NV, Leuven, Belgium) was used to postprocess the volume data to obtain a 3D digital model of fetal heart and large blood vessel morphologic characteristics and to output the file to a 3D printer for printing the 3D model of the fetal heart and large blood vessels. The effect accuracy of the 3D printed model was qualitatively evaluated by showing the 3D anatomic structure of the model combined with echocardiographic or autopsy results, and the dimensional accuracy of the 3D printed model was quantitatively evaluated by comparing the measured data of the model and echocardiography. RESULTS In all 30 fetuses, STIC volume data of the fetal heart were successfully reprocessed and printed out, which could visually display the morphologic characteristics of the fetal heart chamber and passage of the great vessels under normal and abnormal pathologic conditions. No significant differences in all of the heart size parameters were found between the 3D digital model, 3D printed model, and routine echocardiographic images (all P > .05). Moreover, the size parameters were concordant well between the methods, and all of the data points fell within the limits of agreement. CONCLUSIONS It is feasible to 3D print the fetal heart using STIC volumetric images as the data source, and the 3D printed model can fully and accurately display abnormal anatomic structures of the heart.
Collapse
Affiliation(s)
- Jia Huang
- Ultrasonography Center of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Hua Shi
- Ultrasonography Center of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Qian Chen
- Ultrasonography Center of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Jiaqi Hu
- Ultrasonography Center of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Yuguo Zhang
- Ultrasonography Center of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Hongning Song
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, China
| | - Qing Zhou
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, China
| |
Collapse
|
4
|
Gembicki M, Hartge DR, Dracopoulos C, Weichert J. Semiautomatic Fetal Intelligent Navigation Echocardiography Has the Potential to Aid Cardiac Evaluations Even in Less Experienced Hands. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:301-309. [PMID: 31411353 DOI: 10.1002/jum.15105] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Accepted: 07/12/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES To investigate the interobserver and intraobserver variability and corresponding learning curve in a semiautomatic approach for a standardized assessment of the fetal heart (fetal intelligent navigation echocardiography [FINE]). METHODS A total of 30 stored spatiotemporal image correlation volume data sets of second-trimester fetuses were evaluated by 3 physicians with different levels of expertise in fetal echocardiography by using the FINE approach. Data were analyzed regarding the examination time and proper reconstruction of the diagnostic cardiac planes. The completions and numbers of correct depictions of all diagnostic planes were evaluated by a blinded expert (time t0). To determine interobserver and intraobserver variability, the volumes were reassessed after a 4-week training interval (time t1). RESULTS All operators were able to perform the investigation on all 30 volumes. At t0, the interobserver variability between the beginner and both the advanced (P = .0013) and expert (P < .0001) examiners was high. Focusing on intraobserver variability at t1, the beginner showed a marked improvement (P = .0087), whereas in advanced and expert hands, no further improvement regarding proper achievement of all diagnostic planes could be noticed (P > .999; P = .8383). The beginner also showed improvement in the mean investigation time (t0, 82.8 seconds; t1, 73.4 seconds; P = .0895); nevertheless, the advanced and expert examiners were faster in completing the examination (t1, advanced, 20.9 seconds; expert, 28.3 seconds; each P < .0001). CONCLUSIONS Based on our results, the FINE technique is a reliable and easily learned method. The use of this semiautomatic work flow-based approach supports evaluation of the fetal heart in a standardized and time-saving manner. A semiautomatic evaluation of the fetal heart might be useful in facilitating the detection of fetal cardiac anomalies.
Collapse
Affiliation(s)
- Michael Gembicki
- Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, Luebeck, Germany
| | - David R Hartge
- Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, Luebeck, Germany
| | - Christoph Dracopoulos
- Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, Luebeck, Germany
| | - Jan Weichert
- Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Campus Luebeck, Luebeck, Germany
| |
Collapse
|
5
|
Yeo L, Luewan S, Romero R. Fetal Intelligent Navigation Echocardiography (FINE) Detects 98% of Congenital Heart Disease. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:2577-2593. [PMID: 29603310 PMCID: PMC6165712 DOI: 10.1002/jum.14616] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Revised: 02/08/2018] [Accepted: 02/16/2018] [Indexed: 05/05/2023]
Abstract
OBJECTIVE Fetal intelligent navigation echocardiography (FINE) is a novel method that automatically generates and displays 9 standard fetal echocardiographic views in normal hearts by applying intelligent navigation technology to spatiotemporal image correlation (STIC) volume data sets. The main objective was to determine the sensitivity and specificity of FINE in the prenatal detection of congenital heart disease (CHD). METHODS A case-control study was conducted in 50 fetuses with a broad spectrum of CHD (cases) and 100 fetuses with normal hearts (controls) in the second and third trimesters. Using 4-dimensional ultrasound with STIC technology, volume data sets were acquired. After all identifying information was removed, the data sets were randomly distributed to a different investigator for analysis using FINE. The sensitivity and specificity for the prenatal detection of CHD, as well as positive and negative likelihood ratios were determined. RESULTS The diagnostic performance of FINE for the prenatal detection of CHD was: sensitivity of 98% (49 of 50), specificity of 93% (93 of 100), positive likelihood ratio of 14, and negative likelihood ratio of 0.02. Among cases with confirmed CHD, the diagnosis with use of FINE completely matched the final diagnosis in 74% (37 of 50); minor discrepancies were seen in 12% (6 of 50), and major discrepancies were seen in 14% (7 of 50). CONCLUSIONS This is the first time the sensitivity and specificity of the FINE method in fetuses with normal hearts and CHD in the second and third trimesters has been reported. Because FINE identifies a broad spectrum of CHD with 98% sensitivity, this method could be used prenatally to screen for and diagnose CHD.
Collapse
Affiliation(s)
- Lami Yeo
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of HealthBethesda, Maryland, and DetroitMichiganUSA
- Detroit Medical CenterHutzel Women's HospitalDetroitMichiganUSA
- Department of Obstetrics and GynecologyWayne State University School of MedicineDetroitMichiganUSA
| | - Suchaya Luewan
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of HealthBethesda, Maryland, and DetroitMichiganUSA
- Department of Obstetrics and GynecologyChiang Mai UniversityChiang MaiThailand
| | - Roberto Romero
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of HealthBethesda, Maryland, and DetroitMichiganUSA
- Department of Obstetrics and GynecologyUniversity of MichiganAnn ArborMichiganUSA
- Department of Epidemiology and BiostatisticsMichigan State UniversityEast LansingMichiganUSA
- Center for Molecular Medicine and GeneticsWayne State UniversityDetroitMichiganUSA
| |
Collapse
|
6
|
Abstract
With the introduction of the electronic 4-dimensional and spatial-temporal image Correlation (e-STIC), it is now possible to obtain large volume datasets of the fetal heart that are virtually free of artifact. This allows the examiner to use a number of imaging modalities when recording the volumes that include two-dimensional real time, power and color Doppler, and B-flow images. Once the volumes are obtained, manipulation of the volume dataset allows the examiner to recreate views of the fetal heart that enable examination of cardiac anatomy. The value of this technology is that a volume of the fetal heart can be obtained, irrespective of the position of the fetus in utero, and manipulated to render images for interpretation and diagnosis. This article presents a summary of the various imaging techniques and provides clinical examples of its application used for prenatal diagnosis of congenital heart defects and abnormal cardiac function.
Collapse
Affiliation(s)
- Greggory R DeVore
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.,Fetal Diagnostic Centers, Pasadena, Tarzana, and Lancaster, CA, USA
| | - Gary Satou
- Division of Pediatric Cardiology, Department of Pediatrics, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| | - Mark Sklansky
- Division of Pediatric Cardiology, Department of Pediatrics, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| |
Collapse
|
7
|
Veronese P, Bogana G, Cerutti A, Yeo L, Romero R, Gervasi MT. A Prospective Study of the Use of Fetal Intelligent Navigation Echocardiography (FINE) to Obtain Standard Fetal Echocardiography Views. Fetal Diagn Ther 2016; 41:89-99. [PMID: 27309391 DOI: 10.1159/000446982] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Accepted: 05/14/2016] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To evaluate the performance of Fetal Intelligent Navigation Echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volume datasets of the normal fetal heart in generating standard fetal echocardiography views. METHODS In this prospective cohort study of patients with normal fetal hearts (19-30 gestational weeks), one or more STIC volume datasets were obtained of the apical four-chamber view. Each STIC volume successfully obtained was evaluated by STICLoop™ to determine its appropriateness before applying the FINE method. Visualization rates for standard fetal echocardiography views using diagnostic planes and/or Virtual Intelligent Sonographer Assistance (VIS-Assistance®) were calculated. RESULTS One or more STIC volumes (total n = 463) were obtained from 246 patients. A single STIC volume per patient was analyzed using the FINE method. In normal cases, FINE was able to generate nine fetal echocardiography views using: (1) diagnostic planes in 76-100% of the cases, (2) VIS-Assistance® in 96-100% of the cases, and (3) a combination of diagnostic planes and/or VIS-Assistance® in 96-100% of the cases. CONCLUSION FINE applied to STIC volumes can successfully generate nine standard fetal echocardiography views in 96-100% of cases in the 2nd and 3rd trimesters. This suggests that the technology can be used as a method of screening for congenital heart disease.
Collapse
Affiliation(s)
- Paola Veronese
- Unit of Maternal Fetal Medicine, Department of Women's and Children's Health, Azienda Ospedaliera di Padova (AOP), Padua, Italy
| | | | | | | | | | | |
Collapse
|
8
|
Yeo L, Romero R. How to Acquire Cardiac Volumes for Sonographic Examination of the Fetal Heart: Part 2. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:1043-66. [PMID: 27091912 PMCID: PMC8475629 DOI: 10.7863/ultra.16.01082] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Accepted: 03/13/2016] [Indexed: 05/04/2023]
Abstract
The effective performance of fetal cardiac examination using spatiotemporal image correlation (STIC) technology requires 2 essential steps: volume acquisition and postprocessing. An important prerequisite is training sonologists to acquire high-quality volume data sets so that when analyzed, such volumes are informative. This article is part 2 of a series on 4-dimensional sonography with STIC. Part 1 focused on STIC technology and its features, the importance of operator training/experience and acquisition of high-quality STIC volumes, factors that affect STIC volume acquisition rates, and general recommendations on performing 4D sonography with STIC. In part 2, we discuss a detailed and practical stepwise approach for STIC volume acquisition, along with methods to determine whether such volumes are appropriate for analysis.
Collapse
Affiliation(s)
- Lami Yeo
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Hutzel Women’s Hospital, Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Roberto Romero
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, USA
- Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI, USA
- Center for Molecular Medicine and Genetics, Wayne State University, Detroit, MI, USA
| |
Collapse
|
9
|
Yeo L, Romero R. How to Acquire Cardiac Volumes for Sonographic Examination of the Fetal Heart: Part 1. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:1021-42. [PMID: 27091914 PMCID: PMC8475630 DOI: 10.7863/ultra.16.01081] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Accepted: 02/29/2016] [Indexed: 05/13/2023]
Abstract
Four-dimensional sonography with spatiotemporal image correlation (STIC) technology allows acquisition of a fetal cardiac volume data set and displays a cine loop of a complete single cardiac cycle in motion. Part 1 of this 2-part article reviews STIC technology and its features, the importance of operator training/experience, and acquisition of high-quality STIC volumes, as well as factors that affect STIC volume acquisition rates. We also propose a detailed and practical stepwise approach to performing 4-dimensional sonography with STIC and begin herein by providing general recommendations. Part 2 will discuss specifics of the approach, along with how to determine whether such volumes are appropriate for analysis.
Collapse
Affiliation(s)
- Lami Yeo
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Hutzel Women’s Hospital, Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Roberto Romero
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, USA
- Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI, USA
- Department of Molecular Obstetrics and Genetics, Wayne State University, Detroit, MI, USA
| |
Collapse
|
10
|
Yeo L, Romero R. Intelligent navigation to improve obstetrical sonography. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2016; 47:403-9. [PMID: 26525650 PMCID: PMC6419502 DOI: 10.1002/uog.12562] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Revised: 02/06/2013] [Accepted: 02/13/2013] [Indexed: 05/13/2023]
Abstract
'Manual navigation' by the operator is the standard method used to obtain information from two-dimensional and volumetric sonography. Two-dimensional sonography is highly operator dependent and requires extensive training and expertise to assess fetal anatomy properly. Most of the sonographic examination time is devoted to acquisition of images, while 'retrieval' and display of diagnostic planes occurs rapidly (essentially instantaneously). In contrast, volumetric sonography has a rapid acquisition phase, but the retrieval and display of relevant diagnostic planes is often time-consuming, tedious and challenging. We propose the term 'intelligent navigation' to refer to a new method of interrogation of a volume dataset whereby identification and selection of key anatomical landmarks allow the system to: 1) generate a geometrical reconstruction of the organ of interest; and 2) automatically navigate, find, extract and display specific diagnostic planes. This is accomplished using operator-independent algorithms that are both predictable and adaptive. Virtual Intelligent Sonographer Assistance (VIS-Assistance®) is a tool that allows operator-independent sonographic navigation and exploration of the surrounding structures in previously identified diagnostic planes. The advantage of intelligent (over manual) navigation in volumetric sonography is the short time required for both acquisition and retrieval and display of diagnostic planes. Intelligent navigation technology automatically realigns the volume, and reorients and standardizes the anatomical position, so that the fetus and the diagnostic planes are consistently displayed in the same manner each time, regardless of the fetal position or the initial orientation. Automatic labeling of anatomical structures, subject orientation and each of the diagnostic planes is also possible. Intelligent navigation technology can operate on conventional computers, and is not dependent on specific ultrasound platforms or on the use of software to perform manual navigation of volume datasets. Diagnostic planes and VIS-Assistance videoclips can be transmitted by telemedicine so that expert consultants can evaluate the images to provide an opinion. The end result is a user-friendly, simple, fast and consistent method of obtaining sonographic images with decreased operator dependency. Intelligent navigation is one approach to improve obstetrical sonography. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Collapse
Affiliation(s)
- Lami Yeo
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD.
- Detroit, MI, USA.
- Department of Obstetrics and Gynecology, Wayne State University, Detroit, MI, USA.
- Detroit Medical Center, Hutzel Women's Hospital, Detroit, MI, USA.
| | - Roberto Romero
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD.
- Detroit, MI, USA.
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, USA.
- Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI, USA.
- Department of Molecular Obstetrics and Genetics, Wayne State University, Detroit, MI, USA.
| |
Collapse
|
11
|
Garcia M, Yeo L, Romero R, Haggerty D, Giardina I, Hassan SS, Chaiworapongsa T, Hernandez-Andrade E. Prospective evaluation of the fetal heart using Fetal Intelligent Navigation Echocardiography (FINE). ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2016; 47:450-9. [PMID: 26278116 PMCID: PMC5898803 DOI: 10.1002/uog.15676] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2015] [Revised: 08/05/2015] [Accepted: 08/10/2015] [Indexed: 05/21/2023]
Abstract
OBJECTIVE To evaluate prospectively the performance of Fetal Intelligent Navigation Echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volume datasets of the normal fetal heart. METHODS In all women between 19 and 30 weeks' gestation with a normal fetal heart, an attempt was made to acquire STIC volume datasets of the apical four-chamber view if the following criteria were met: (1) fetal spine located between 5- and 7-o'clock positions; (2) minimal or absent shadowing (including a clearly visible transverse aortic arch); (3) absence of fetal breathing, hiccups, or movement; and (4) adequate image quality. Each STIC volume successfully acquired was evaluated by STICLoop™ to determine its appropriateness before applying the FINE method. Visualization rates of fetal echocardiography views using diagnostic planes and/or Virtual Intelligent Sonographer Assistance (VIS-Assistance®) were calculated. RESULTS One or more STIC volumes (365 in total) were obtained successfully in 72.5% (150/207) of women undergoing ultrasound examination. Of the 365 volumes evaluated by STICLoop, 351 (96.2%) were considered to be appropriate. From the 351 STIC volumes, only one STIC volume per patient (n = 150) was analyzed using the FINE method, and consequently nine fetal echocardiography views were generated in 76-100% of cases using diagnostic planes only, in 98-100% of cases using VIS-Assistance only, and in 98-100% of cases when using a combination of diagnostic planes and/or VIS-Assistance. CONCLUSIONS In women between 19 and 30 weeks' gestation with a normal fetal heart undergoing prospective sonographic examination, STIC volumes can be obtained successfully in 72.5% of cases. The FINE method can be applied to generate nine standard fetal echocardiography views in 98-100% of these cases using a combination of diagnostic planes and/or VIS-Assistance. This suggests that FINE could be implemented in fetal cardiac screening programs. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Collapse
Affiliation(s)
- Maynor Garcia
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Hutzel Women’s Hospital, Detroit, MI, USA
| | - Lami Yeo
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Hutzel Women’s Hospital, Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Roberto Romero
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, USA
- Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI, USA
- Center for Molecular Medicine and Genetics, Wayne State University, Detroit, MI, USA
| | - Denise Haggerty
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Hutzel Women’s Hospital, Detroit, MI, USA
| | - Irene Giardina
- Department of Obstetrics and Gynecology, University of Perugia, Perugia, Italy
| | - Sonia S. Hassan
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Hutzel Women’s Hospital, Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Tinnakorn Chaiworapongsa
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Hutzel Women’s Hospital, Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Edgar Hernandez-Andrade
- Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, NIH, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Hutzel Women’s Hospital, Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| |
Collapse
|
12
|
Jatavan T, Tongsong T. Comparison of fetal cardiac spatiotemporal image correlation segmental analysis between cardiac- and body-based scrolling. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2013; 32:2125-2129. [PMID: 24277894 DOI: 10.7863/ultra.32.12.2125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
OBJECTIVES The purpose of this study was to compare success rates for depiction of the 5 typical transverse planes in the fetal upper thorax between cardiac- and body-based scrolling techniques. METHODS Spatiotemporal image correlation volume data sets acquired at the 4-chamber view level were obtained from low-risk singleton pregnancies with healthy fetuses. Each data set was analyzed by the authors using both cardiac- and body-based techniques. With the cardiac-based technique, the exact 4-chamber view was first identified as an initial plane before scrolling, whereas with the body-based technique, a volume data set was first manipulated to get the fetal orientation in the exact dorsal supine position as an initial plane. In both techniques, the volumes were then scrolled through the upper thorax to identify the standard planes, including the 4-chamber, 5-chamber, 3-vessel, 3-vessel and trachea, and aortic arch views. RESULTS An analysis of 50 volume data sets to evaluate intraobserver and interobserver variability in the success rates for the 4-chamber, 5-chamber, 3-vessel, 3-vessel and trachea, and aortic arch views showed good agreement. In an analysis of 296 separate data sets, cardiac-based scrolling was associated with significantly higher success rates than body-based scrolling in all standard planes (P < .05). CONCLUSIONS Cardiac-based scrolling resulted in higher success rates for obtaining the standard spatiotemporal image correlation planes than body-based scrolling. Therefore, examiners in the early part of the learning curve should be encouraged to first identify a perfect 4-chamber view at the start of an examination.
Collapse
Affiliation(s)
- Thanate Jatavan
- Department of Obstetrics and Gynecology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand.
| | | |
Collapse
|
13
|
Yeo L, Romero R. Fetal Intelligent Navigation Echocardiography (FINE): a novel method for rapid, simple, and automatic examination of the fetal heart. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2013; 42:268-84. [PMID: 24000158 PMCID: PMC9651141 DOI: 10.1002/uog.12563] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Revised: 02/07/2013] [Accepted: 02/13/2013] [Indexed: 05/21/2023]
Abstract
OBJECTIVE To describe a novel method (Fetal Intelligent Navigation Echocardiography (FINE)) for visualization of standard fetal echocardiography views from volume datasets obtained with spatiotemporal image correlation (STIC) and application of 'intelligent navigation' technology. METHODS We developed a method to: 1) demonstrate nine cardiac diagnostic planes; and 2) spontaneously navigate the anatomy surrounding each of the nine cardiac diagnostic planes (Virtual Intelligent Sonographer Assistance (VIS-Assistance®)). The method consists of marking seven anatomical structures of the fetal heart. The following echocardiography views are then automatically generated: 1) four chamber; 2) five chamber; 3) left ventricular outflow tract; 4) short-axis view of great vessels/right ventricular outflow tract; 5) three vessels and trachea; 6) abdomen/stomach; 7) ductal arch; 8) aortic arch; and 9) superior and inferior vena cava. The FINE method was tested in a separate set of 50 STIC volumes of normal hearts (18.6-37.2 weeks of gestation), and visualization rates for fetal echocardiography views using diagnostic planes and/or VIS-Assistance® were calculated. To examine the feasibility of identifying abnormal cardiac anatomy, we tested the method in four cases with proven congenital heart defects (coarctation of aorta, tetralogy of Fallot, transposition of great vessels and pulmonary atresia with intact ventricular septum). RESULTS In normal cases, the FINE method was able to generate nine fetal echocardiography views using: 1) diagnostic planes in 78-100% of cases; 2) VIS-Assistance® in 98-100% of cases; and 3) a combination of diagnostic planes and/or VIS-Assistance® in 98-100% of cases. In all four abnormal cases, the FINE method demonstrated evidence of abnormal fetal cardiac anatomy. CONCLUSIONS The FINE method can be used to visualize nine standard fetal echocardiography views in normal hearts by applying 'intelligent navigation' technology to STIC volume datasets. This method can simplify examination of the fetal heart and reduce operator dependency. The observation of abnormal echocardiography views in the diagnostic planes and/or VIS-Assistance® should raise the index of suspicion for congenital heart disease.
Collapse
Affiliation(s)
- Lami Yeo
- Perinatology Research Branch, National Institute for Child Health and Human Development-NIH/DHHS, Bethesda, MD 20892, USA.
| | | |
Collapse
|