1
|
Oki Y, Uehara K, Mizonobe K, Akasaka H, Shiota Y, Sakamoto R, Harada A, Kitatani K, Yabuuchi T, Miyazaki S, Hattori T, Mayahara H. Plan comparison of prostate stereotactic radiotherapy in spacer implant patients. J Appl Clin Med Phys 2021; 22:280-288. [PMID: 34359100 PMCID: PMC8425928 DOI: 10.1002/acm2.13387] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/31/2021] [Accepted: 07/26/2021] [Indexed: 01/26/2023] Open
Abstract
In prostate stereotactic body radiation therapy (SBRT), hydrogel spacers are increasingly used. This study aimed to perform a dosimetry comparison of treatment plans using CyberKnife (CK), commonly used for prostate SBRT, Helical TomoTherapy (HT), and TrueBeam (TB) in patients with hydrogel spacer implantations. The data of 20 patients who received hydrogel spacer implantation for prostate SBRT were retrospectively analyzed. The prescription dose was 36.25 Gy in five fractions to 95% of the planning target volume (PTV; D95). The conformity index (CI), gradient index (GI), homogeneity index (HI), and dose‐volume histogram (DVH) were analyzed for the three modalities, using the same PTV margins. The monitor unit (MU) and the beam‐on‐time (BOT) values were subsequently compared. The CI of TB (0.93 ± 0.02) was significantly superior to those of CK (0.82 ± 0.03, p < 0.01) and HT (0.86 ± 0.03, p < 0.01). Similarly, the GI value of TB (3.59 ± 0.12) was significantly better than those of CK (4.31 ± 0.43, p < 0.01) and HT (4.52 ± 0.24, p < 0.01). The median doses to the bladder did not differ between the CK and TB (V18.1 Gy: 16.5% ± 4.5% vs. 15.8% ± 4.4%, p = 1.00), but were significantly higher for HT (V18.1 Gy: 33.2% ± 7.3%, p < 0.01 vs. CK, p < 0.01 vs. TB). The median rectal dose was significantly lower for TB (V18.1 Gy: 5.6% ± 4.5%) than for CK (V18.1 Gy: 11.2% ± 6.7%, p < 0.01) and HT (20.2% ± 8.3%, p < 0.01). TB had the shortest BOT (2.6 min; CK: 17.4 min, HT: 6.9 min). TB could create treatment plans dosimetrically comparable to those of CK when using the same margins, in patients with hydrogel spacers.
Collapse
Affiliation(s)
- Yuya Oki
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Kazuyuki Uehara
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Kazufusa Mizonobe
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Hiroaki Akasaka
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan.,Division of Radiation Oncology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan
| | - Yuichirou Shiota
- Division of Radiological Technology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Risako Sakamoto
- Division of Radiological Technology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Aya Harada
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Keiji Kitatani
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Tomonori Yabuuchi
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Shuichirou Miyazaki
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Takayuki Hattori
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| | - Hiroshi Mayahara
- Division of Radiation Oncology, Kobe Minimally Invasive Cancer Center, Kobe, Hyogo, Japan
| |
Collapse
|
2
|
Mannerberg A, Persson E, Jonsson J, Gustafsson CJ, Gunnlaugsson A, Olsson LE, Ceberg S. Dosimetric effects of adaptive prostate cancer radiotherapy in an MR-linac workflow. Radiat Oncol 2020; 15:168. [PMID: 32650811 PMCID: PMC7350593 DOI: 10.1186/s13014-020-01604-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 06/23/2020] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND The purpose was to evaluate the dosimetric effects in prostate cancer treatment caused by anatomical changes occurring during the time frame of adaptive replanning in a magnetic resonance linear accelerator (MR-linac) workflow. METHODS Two MR images (MR1 and MR2) were acquired with 30 min apart for each of the 35 patients enrolled in this study. The clinical target volume (CTV) and organs at risk (OARs) were delineated based on MR1. Using a synthetic CT (sCT), ultra-hypofractionated VMAT treatment plans were created for MR1, with three different planning target volume (PTV) margins of 7 mm, 5 mm and 3 mm. The three treatment plans of MR1, were recalculated onto MR2 using its corresponding sCT. The dose distribution of MR2 represented delivered dose to the patient after 30 min of adaptive replanning, omitting motion correction before beam on. MR2 was registered to MR1, using deformable registration. Using the inverse deformation, the structures of MR1 was deformed to fit MR2 and anatomical changes were quantified. For dose distribution comparison the dose distribution of MR2 was warped to the geometry MR1. RESULTS The mean center of mass vector offset for the CTV was 1.92 mm [0.13 - 9.79 mm]. Bladder volume increase ranged from 12.4 to 133.0% and rectum volume difference varied between -10.9 and 38.8%. Using the conventional 7 mm planning target volume (PTV) margin the dose reduction to the CTV was 1.1%. Corresponding values for 5 mm and 3 mm PTV margin were 2.0% and 4.2% respectively. The dose to the PTV and OARs also decreased from D1 to D2, for all PTV margins evaluated. Statistically significant difference was found for CTV Dmin between D1 and D2 for the 3 mm PTV margin (p < 0.01). CONCLUSIONS A target underdosage caused by anatomical changes occurring during the reported time frame for adaptive replanning MR-linac workflows was found. Volume changes in both bladder and rectum caused large prostate displacements. This indicates the importance of thorough position verification before treatment delivery and that the workflow needs to speed up before introducing margin reduction.
Collapse
Affiliation(s)
- Annika Mannerberg
- Department of Medical Radiation Physics, Lund University, Lund, Sweden.
| | - Emilia Persson
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
- Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden
| | - Joakim Jonsson
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | - Christian Jamtheim Gustafsson
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
- Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden
| | - Adalsteinn Gunnlaugsson
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Lars E Olsson
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
- Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö, Sweden
| | - Sofie Ceberg
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
| |
Collapse
|
3
|
de Muinck Keizer DM, Kerkmeijer LGW, Maspero M, Andreychenko A, van der Voort van Zyp JRN, van den Berg CAT, Raaymakers BW, Lagendijk JJW, de Boer JCJ. Soft-tissue prostate intrafraction motion tracking in 3D cine-MR for MR-guided radiotherapy. Phys Med Biol 2019; 64:235008. [PMID: 31698351 DOI: 10.1088/1361-6560/ab5539] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
To develop a method to automatically determine intrafraction motion of the prostate based on soft tissue contrast on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients who underwent prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold fiducial markers (FMs), had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR session consisted of 55 sequentially obtained 3D data sets ('dynamics') and was acquired over an 11 s period, covering a total of 10 min. The prostate was delineated on the first dynamic of every dataset and this delineation was used as the starting position for the soft tissue tracking (SST). Each subsequent dynamic was rigidly aligned to the first dynamic, based on the contrast of the prostate. The obtained translation and rotation describes the intrafraction motion of the prostate. The algorithm was applied to 6270 dynamics over 114 scans of 29 patients and the results were validated by comparing to previously obtained fiducial marker tracking data of the same dataset. Our proposed tracking method was also retro-perspectively applied to cine-MR images acquired during MR-guided radiotherapy of our first prostate patient treated on the MR-Linac. The difference in the 3D translation results between the soft tissue and marker tracking was below 1 mm for 98.2% of the time. The mean translation at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.8 mm and Z: [Formula: see text] mm. The mean rotation results at 10 min were X: [Formula: see text], Y: 0.1 [Formula: see text] 0.6° and Z: 0.0 [Formula: see text] 0.7°. A fast, robust and accurate SST algorithm was developed which obviates the need for FMs during MR-guided prostate radiotherapy. To our knowledge, this is the first data using full 3D cine-MR images for real-time soft tissue prostate tracking, which is validated against previously obtained marker tracking data.
Collapse
Affiliation(s)
- D M de Muinck Keizer
- Department of Radiotherapy, University Medical Center Utrecht, 3508 GA, Utrecht, The Netherlands. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Lapierre A, Horn S, Créhange G, Enachescu C, Latorzeff I, Supiot S, Sargos P, Hennequin C, Chapet O. Radiothérapie stéréotaxique extracrânienne : quelle machine pour quelle indication ? Stéréotaxie prostatique. Cancer Radiother 2019; 23:651-657. [DOI: 10.1016/j.canrad.2019.06.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 06/26/2019] [Indexed: 10/26/2022]
|
5
|
de Muinck Keizer DM, Pathmanathan AU, Andreychenko A, Kerkmeijer LGW, van der Voort van Zyp JRN, Tree AC, van den Berg CAT, de Boer JCJ. Fiducial marker based intra-fraction motion assessment on cine-MR for MR-linac treatment of prostate cancer. Phys Med Biol 2019; 64:07NT02. [PMID: 30794995 DOI: 10.1088/1361-6560/ab09a6] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
We have developed a method to determine intrafraction motion of the prostate through automatic fiducial marker (FM) tracking on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients undergoing prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold FMs, had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR examination consisted of 55 sequentially obtained 3D datasets ('dynamics'), acquired over a 11 s period, covering a total of 10 min. FM locations in the first dynamic were manually identified by a clinician, FM centers in subsequent dynamics were automatically determined. Center of mass (COM) translations and rotations were determined by calculating the rigid transformations between the FM template of the first and subsequent dynamics. The algorithm was applied to 7315 dynamics over 133 scans of 29 patients and the obtained results were validated by comparing the COM locations recorded by the clinician at the halfway-dynamic (after 5 min) and end dynamic (after 10 min). The mean COM translations at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.9 mm and Z: 0.9 [Formula: see text] 2.0 mm. The mean rotation results at 10 min were X: 0.1 [Formula: see text] 3.9°, Y: 0.0 [Formula: see text] 1.3° and Z: 0.1 [Formula: see text] 1.2°. The tracking success rate was 97.7% with a mean 3D COM error of 1.1 mm. We have developed a robust, fast and accurate FM tracking algorithm for cine-MR data, which allows for continuous monitoring of prostate motion during MR-guided radiotherapy (MRgRT). These results will be used to validate automatic prostate tracking based on soft-tissue contrast.
Collapse
Affiliation(s)
- D M de Muinck Keizer
- Department of Radiotherapy, University Medical Center Utrecht, PO Box 85500, 3508 GA, Utrecht, The Netherlands. Joint first author. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Winkel D, Bol GH, Werensteijn-Honingh AM, Kiekebosch IH, van Asselen B, Intven MP, Eppinga WS, Raaymakers BW, Jürgenliemk-Schulz IM, Kroon PS. Evaluation of plan adaptation strategies for stereotactic radiotherapy of lymph node oligometastases using online magnetic resonance image guidance. Phys Imaging Radiat Oncol 2019; 9:58-64. [PMID: 33458426 PMCID: PMC7807584 DOI: 10.1016/j.phro.2019.02.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 02/11/2019] [Accepted: 02/19/2019] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND AND PURPOSE Recent studies have shown that the use of magnetic resonance (MR) guided online plan adaptation yields beneficial dosimetric values and reduces unplanned violations of the dose constraints for stereotactic body radiation therapy (SBRT) of lymph node oligometastases. The purpose of this R-IDEAL stage 0 study was to determine the optimal plan adaptation approach for MR-guided SBRT treatment of lymph node oligometastases. MATERIALS AND METHODS Using pre-treatment computed tomography (CT) and repeated MR data from five patients with in total 17 pathological lymph nodes, six different methods of plan adaptation were performed on the daily MRI and contours. To determine the optimal plan adaptation approach for treatment of lymph node oligometastases, the adapted plans were evaluated using clinical dose criteria and the time required for performing the plan adaptation. RESULTS The average time needed for the different plan adaptation methods ranged between 11 and 119 s. More advanced adaptation methods resulted in more plans that met the clinical dose criteria [range, 0-16 out of 17 plans]. The results show a large difference between target coverage achieved by the different plan adaptation methods. CONCLUSION Results suggested that multiple plan adaptation methods, based on plan adaptation on the daily anatomy, were feasible for MR-guided SBRT treatment of lymph node oligometastases. The most advanced method, in which a full online replanning was performed by segment shape and weight optimization after fluence optimization, yielded the most favourable dosimetric values and could be performed within a time-frame acceptable (<5 min) for MR-guided treatment.
Collapse
Affiliation(s)
- Dennis Winkel
- Department of Radiotherapy, University Medical Center, Utrecht, the Netherlands
| | - Gijsbert H. Bol
- Department of Radiotherapy, University Medical Center, Utrecht, the Netherlands
| | | | - Ilse H. Kiekebosch
- Department of Radiotherapy, University Medical Center, Utrecht, the Netherlands
| | - Bram van Asselen
- Department of Radiotherapy, University Medical Center, Utrecht, the Netherlands
| | - Martijn P.W. Intven
- Department of Radiotherapy, University Medical Center, Utrecht, the Netherlands
| | - Wietse S.C. Eppinga
- Department of Radiotherapy, University Medical Center, Utrecht, the Netherlands
| | - Bas W. Raaymakers
- Department of Radiotherapy, University Medical Center, Utrecht, the Netherlands
| | | | - Petra S. Kroon
- Department of Radiotherapy, University Medical Center, Utrecht, the Netherlands
| |
Collapse
|
7
|
Benedek H, Lerner M, Nilsson P, Knöös T, Gunnlaugsson A, Ceberg C. The effect of prostate motion during hypofractionated radiotherapy can be reduced by using flattening filter free beams. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2018; 6:66-70. [PMID: 33458391 PMCID: PMC7807632 DOI: 10.1016/j.phro.2018.05.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Revised: 05/04/2018] [Accepted: 05/06/2018] [Indexed: 11/29/2022]
Abstract
Background and purpose Hypofractionated radiotherapy of prostate cancer reduces the overall treatment time but increases the per-fraction beam-on time due to the higher fraction doses. This increased fraction treatment time results in a larger uncertainty of the prostate position. The purpose of this study was to investigate the effect of prostate motion during flattening filter free (FFF) Volumetric Modulated Arc Therapy (VMAT) in ultrahypofractionation of prostate cancer radiotherapy with preserved plan quality compared to conventional flattened beams. Materials and methods Nine prostate patients from the Scandinavian HYPO-RT-PC trial were re-planned using VMAT technique with both conventional and flattening filter free beams. Two fractionation schedules were used, one hypofractionated (42.7 Gy in 7 fractions), and one conventional (78.0 Gy in 39 fractions). Pre-treatment verification measurements were performed on all plans and the treatment time was recorded. Measurements with simulated prostate motion were performed for the plans with the longest treatment times. Results All the 10FFF plans fulfilled the clinical gamma pass rate, 90% (3%, 2 mm), during all simulated prostate motion trajectories. The 10MV plans only fulfilled the clinical pass rate for three of the trajectories. The mean beam-on-time for the hypofractionated plans were reduced from 2.3 min to 1.0 min when using 10FFF compared to 10MV. No clinically relevant differences in dose distribution were identified when comparing the plans with different beam qualities. Conclusion Flattening-filter free VMAT reduces treatment times, limiting the dosimetric effect of organ motion for ultrahypofractionated prostate cancer with preserved plan quality.
Collapse
Affiliation(s)
- Hunor Benedek
- Department of Haematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.,Department of Medical Radiation Physics, Clinical Sciences, Lund University, Lund, Sweden
| | - Minna Lerner
- Department of Haematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Per Nilsson
- Department of Haematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.,Department of Medical Radiation Physics, Clinical Sciences, Lund University, Lund, Sweden
| | - Tommy Knöös
- Department of Haematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.,Department of Medical Radiation Physics, Clinical Sciences, Lund University, Lund, Sweden
| | - Adalsteinn Gunnlaugsson
- Department of Haematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Crister Ceberg
- Department of Medical Radiation Physics, Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
8
|
Pang EPP, Knight K, Fan Q, Tan SXF, Ang KW, Master Z, Mui WH, Leung RWK, Baird M, Tuan JKL. Analysis of intra-fraction prostate motion and derivation of duration-dependent margins for radiotherapy using real-time 4D ultrasound. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2018; 5:102-107. [PMID: 33458378 PMCID: PMC7807728 DOI: 10.1016/j.phro.2018.03.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Revised: 03/15/2018] [Accepted: 03/15/2018] [Indexed: 12/02/2022]
Abstract
Investigates the magnitude of intra-fraction prostate motion using real time monitoring. A motion-time trend analysis was presented. A duration-dependent margin was recommended. Larger margins are required around the prostate in the inferior and posterior directions.
Background and purpose During radiotherapy, prostate motion changes over time. Quantifying and accounting for this motion is essential. This study aimed to assess intra-fraction prostate motion and derive duration-dependent planning margins for two treatment techniques. Material and methods A four-dimension (4D) transperineal ultrasound Clarity® system was used to track prostate motion. We analysed 1913 fractions from 60 patients undergoing volumetric-modulated arc therapy (VMAT) to the prostate. The mean VMAT treatment duration was 3.4 min. Extended monitoring was conducted weekly to simulate motion during intensity-modulated radiation therapy (IMRT) treatment (an additional seven minutes). A motion-time trend analysis was conducted and the mean intra-fraction motion between VMAT and IMRT treatments compared. Duration-dependent margins were calculated and anisotropic margins for VMAT and IMRT treatments were derived. Results There were statistically significant differences in the mean intra-fraction motion between VMAT and the simulated IMRT duration in the inferior (0.1 mm versus 0.3 mm) and posterior (−0.2 versus −0.4 mm) directions respectively (p ≪ 0.01). An intra-fraction motion trend inferiorly and posteriorly was observed. The recommended minimum anisotropic margins are 1.7 mm/2.7 mm (superior/inferior); 0.8 mm (left/right), 1.7 mm/2.9 mm (anterior/posterior) for VMAT treatments and 2.9 mm/4.3 mm (superior/inferior), 1.5 mm (left/right), 2.8 mm/4.8 mm (anterior/posterior) for IMRT treatments. Smaller anisotropic margins were required for VMAT compared to IMRT (differences ranging from 1.2 to 1.6 mm superiorly/inferiorly, 0.7 mm laterally and 1.1–1.9 mm anteriorly/posteriorly). Conclusions VMAT treatment is preferred over IMRT as prostate motion increases with time. Larger margins should be employed in the inferior and posterior directions for both treatment durations. Duration-dependent margins should be applied in the presence of prolonged imaging and verification time.
Collapse
Affiliation(s)
- Eric Pei Ping Pang
- Division of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Drive, Singapore 169610, Singapore
- Faculty of Medicine, Nursing and Health Sciences, Department of Medical Imaging & Radiation Sciences, Monash University, Wellington Road, Clayton, VIC 3800, Australia
- Corresponding author at: Division of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Drive, Singapore 169610, Singapore.
| | - Kellie Knight
- Faculty of Medicine, Nursing and Health Sciences, Department of Medical Imaging & Radiation Sciences, Monash University, Wellington Road, Clayton, VIC 3800, Australia
| | - Qiao Fan
- Centre for Quantitative Medicine, Duke-NUS Medical School, 8 College Road, Singapore 169857, Singapore
| | - Sheena Xue Fei Tan
- Division of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Drive, Singapore 169610, Singapore
| | - Khong Wei Ang
- Division of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Drive, Singapore 169610, Singapore
| | - Zubin Master
- Division of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Drive, Singapore 169610, Singapore
| | - Wing-Ho Mui
- Tuen Mun Hospital, 23 Tsing Chung Koon Road, Tuen Mun, New Territories, Hong Kong
| | | | - Marilyn Baird
- Faculty of Medicine, Nursing and Health Sciences, Department of Medical Imaging & Radiation Sciences, Monash University, Wellington Road, Clayton, VIC 3800, Australia
| | - Jeffrey Kit Loong Tuan
- Division of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Drive, Singapore 169610, Singapore
- Duke-NUS Graduate Medical School, 8 College Road, Singapore 169857, Singapore
| |
Collapse
|
9
|
Njeh CF, Parker BC, Orton CG. Implanted fiducial markers are no longer needed for prostate cancer radiotherapy. Med Phys 2017; 44:6113-6116. [DOI: 10.1002/mp.12633] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Accepted: 10/17/2017] [Indexed: 01/04/2023] Open
Affiliation(s)
| | - Brent C. Parker
- Radiation Oncology; Medical Branch of Galveston; University of Texas; Galveston TX 77555 USA
| | | |
Collapse
|
10
|
Kontaxis C, Bol GH, Kerkmeijer LGW, Lagendijk JJW, Raaymakers BW. Fast online replanning for interfraction rotation correction in prostate radiotherapy. Med Phys 2017; 44:5034-5042. [DOI: 10.1002/mp.12467] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2017] [Revised: 06/05/2017] [Accepted: 07/06/2017] [Indexed: 11/11/2022] Open
Affiliation(s)
- Charis Kontaxis
- Department of Radiotherapy; University Medical Center Utrecht; Heidelberglaan 100 Utrecht 3584 CX The Netherlands
| | - Gijsbert H. Bol
- Department of Radiotherapy; University Medical Center Utrecht; Heidelberglaan 100 Utrecht 3584 CX The Netherlands
| | - Linda G. W. Kerkmeijer
- Department of Radiotherapy; University Medical Center Utrecht; Heidelberglaan 100 Utrecht 3584 CX The Netherlands
| | - Jan J. W. Lagendijk
- Department of Radiotherapy; University Medical Center Utrecht; Heidelberglaan 100 Utrecht 3584 CX The Netherlands
| | - Bas W. Raaymakers
- Department of Radiotherapy; University Medical Center Utrecht; Heidelberglaan 100 Utrecht 3584 CX The Netherlands
| |
Collapse
|
11
|
Zaorsky NG, Showalter TN, Ezzell GA, Nguyen PL, Assimos DG, D'Amico AV, Gottschalk AR, Gustafson GS, Keole SR, Liauw SL, Lloyd S, McLaughlin PW, Movsas B, Prestidge BR, Taira AV, Vapiwala N, Davis BJ. ACR Appropriateness Criteria for external beam radiation therapy treatment planning for clinically localized prostate cancer, part II of II. Adv Radiat Oncol 2017; 2:437-454. [PMID: 29114613 PMCID: PMC5605284 DOI: 10.1016/j.adro.2017.03.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Accepted: 03/10/2017] [Indexed: 12/21/2022] Open
Abstract
PURPOSE To present the most updated American College of Radiology (ACR) Appropriateness Criteria formed by an expert panel on the appropriate delivery of external beam radiation to manage stage T1 and T2 prostate cancer (in the definitive setting and post-prostatectomy) and to provide clinical variants with expert recommendations based on accompanying Appropriateness Criteria for target volumes and treatment planning. METHODS AND MATERIALS The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a panel of multidisciplinary experts. The guideline development and revision process includes an extensive analysis of current medical literature from peer-reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In instances in which evidence is lacking or equivocal, expert opinion may supplement available evidence to recommend imaging or treatment. RESULTS The panel summarizes the most recent and relevant literature on the topic, including organ motion and localization methods, image guidance, and delivery techniques (eg, 3-dimensional conformal intensity modulation). The panel presents 7 clinical variants, including (1) a standard case and cases with (2) a distended rectum, (3) a large-volume prostate, (4) bilateral hip implants, (5) inflammatory bowel disease, (6) prior prostatectomy, and (7) a pannus extending into the radiation field. Each case outlines the appropriate techniques for simulation, treatment planning, image guidance, dose, and fractionation. Numerical rating and commentary is given for each treatment approach in each variant. CONCLUSIONS External beam radiation is a key component of the curative management of T1 and T2 prostate cancer. By combining the most recent medical literature, these Appropriateness Criteria can aid clinicians in determining the appropriate treatment delivery and personalized approaches for individual patients.
Collapse
Affiliation(s)
| | | | - Gary A. Ezzell
- Mayo Clinic, Phoenix, Arizona (research author [contributing])
| | - Paul L. Nguyen
- Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts (panel vice-chair)
| | - Dean G. Assimos
- University of Alabama School of Medicine, Birmingham, Alabama (American Urological Association)
| | - Anthony V. D'Amico
- Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts (American Society of Clinical Oncology)
| | | | | | | | | | - Shane Lloyd
- Huntsman Cancer Hospital, Salt Lake City, Utah
| | | | | | | | - Al V. Taira
- Mills Peninsula Hospital, San Mateo, California
| | - Neha Vapiwala
- University of Pennsylvania, Philadelphia, Pennsylvania
| | | |
Collapse
|
12
|
Dosimetric implications of inter- and intrafractional prostate positioning errors during tomotherapy. Strahlenther Onkol 2017; 193:700-706. [DOI: 10.1007/s00066-017-1141-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2017] [Accepted: 04/07/2017] [Indexed: 10/19/2022]
|
13
|
Fourie N, Ali OA, Rae WID. Development and verification of a time delivery model for prostate intensity modulated radiotherapy using a Siemens® Artiste™ 160 Multi-leaf Collimator Linac. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2017; 40:51-56. [DOI: 10.1007/s13246-016-0518-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2016] [Accepted: 12/24/2016] [Indexed: 11/30/2022]
|
14
|
Seppälä J, Suilamo S, Tenhunen M, Sailas L, Virsunen H, Kaleva E, Keyriläinen J. Dosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer. Technol Cancer Res Treat 2016; 16:238-245. [PMID: 28279147 PMCID: PMC5616037 DOI: 10.1177/1533034616682156] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, noncoplanar intensity-modulated radiotherapy, and 2 intensity-modulated arc therapy techniques (RapidArc and Elekta volumetric-modulated arc therapy). All the plans had equal treatment margins and a prescription dose of 35 Gy in 5 fractions. RESULTS Statistically significant differences were observed in homogeneity index and mean doses of bladder wall and penile bulb, all of which were highest with CyberKnife. No significant differences were observed in the mean doses of rectum, with values of 15.2 ± 2.6, 13.3 ± 2.6, 13.1 ± 2.8, and 13.8 ± 1.6 Gy with CyberKnife, RapidArc, volumetric-modulated arc therapy, and noncoplanar intensity-modulated radiotherapy, respectively. The highest dose conformity was realized with RapidArc. The dose coverage of the planning target volume was lowest with noncoplanar intensity-modulated radiotherapy. Treatment times and number of monitor units were largest with CyberKnife (on average 34.0 ± 5.0 minutes and 8704 ± 1449 monitor units) and least with intensity-modulated arc therapy techniques (on average 5.1 ± 1.1 minutes and 2270 ± 497 monitor units). CONCLUSION Compared to CyberKnife, the RapidArc, volumetric-modulated arc therapy, and noncoplanar intensity-modulated radiotherapy produced treatment plans with similar dosimetric quality, with RapidArc achieving the highest dose conformity. Overall, the dosimetric differences between the studied techniques were marginal, and thus, the choice of the technique should rather focus on the delivery accuracies and dose delivery times.
Collapse
Affiliation(s)
- Jan Seppälä
- 1 Radiotherapy Department, Cancer Center, Kuopio University Hospital, Kuopio, Finland
| | - Sami Suilamo
- 2 Department of Medical Physics & Department of Radiotherapy and Oncology, Turku University Hospital, Turku, Finland
| | - Mikko Tenhunen
- 3 Comprehensive Cancer Center, Helsinki University Central Hospital, Helsinki, Finland
| | - Liisa Sailas
- 4 Department of Radiotherapy, North Karelia Central Hospital, Joensuu, Finland
| | - Heli Virsunen
- 1 Radiotherapy Department, Cancer Center, Kuopio University Hospital, Kuopio, Finland
| | - Erna Kaleva
- 3 Comprehensive Cancer Center, Helsinki University Central Hospital, Helsinki, Finland.,5 Lahti Department of Radiotherapy, Tampere University Hospital, Lahti, Finland
| | - Jani Keyriläinen
- 2 Department of Medical Physics & Department of Radiotherapy and Oncology, Turku University Hospital, Turku, Finland.,3 Comprehensive Cancer Center, Helsinki University Central Hospital, Helsinki, Finland
| |
Collapse
|
15
|
McPartlin AJ, Li XA, Kershaw LE, Heide U, Kerkmeijer L, Lawton C, Mahmood U, Pos F, van As N, van Herk M, Vesprini D, van der Voort van Zyp J, Tree A, Choudhury A. MRI-guided prostate adaptive radiotherapy - A systematic review. Radiother Oncol 2016; 119:371-80. [PMID: 27162159 DOI: 10.1016/j.radonc.2016.04.014] [Citation(s) in RCA: 120] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2016] [Revised: 04/08/2016] [Accepted: 04/09/2016] [Indexed: 11/29/2022]
Abstract
Dose escalated radiotherapy improves outcomes for men with prostate cancer. A plateau for benefit from dose escalation using EBRT may not have been reached for some patients with higher risk disease. The use of increasingly conformal techniques, such as step and shoot IMRT or more recently VMAT, has allowed treatment intensification to be achieved whilst minimising associated increases in toxicity to surrounding normal structures. To support further safe dose escalation, the uncertainties in the treatment target position will need be minimised using optimal planning and image-guided radiotherapy (IGRT). In particular the increasing usage of profoundly hypo-fractionated stereotactic therapy is predicated on the ability to confidently direct treatment precisely to the intended target for the duration of each treatment. This article reviews published studies on the influences of varies types of motion on daily prostate position and how these may be mitigated to improve IGRT in future. In particular the role that MRI has played in the generation of data is discussed and the potential role of the MR-Linac in next-generation IGRT is discussed.
Collapse
Affiliation(s)
- A J McPartlin
- The Christie NHS Foundation Trust and Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Sciences Centre, UK
| | - X A Li
- Medical College of Wisconsin, USA
| | - L E Kershaw
- The Christie NHS Foundation Trust and Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Sciences Centre, UK
| | - U Heide
- Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, The Netherlands
| | - L Kerkmeijer
- University Medical Center Utrecht, The Netherlands
| | - C Lawton
- Medical College of Wisconsin, USA
| | - U Mahmood
- MD Anderson Cancer Center, Houston, USA
| | - F Pos
- Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, The Netherlands
| | - N van As
- Royal Marsden Hospital, UK; Institute of Cancer Research, UK
| | - M van Herk
- The Christie NHS Foundation Trust and Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Sciences Centre, UK
| | - D Vesprini
- Sunnybrook Health Sciences Centre, University of Toronto, Canada
| | | | - A Tree
- Royal Marsden Hospital, UK
| | - A Choudhury
- The Christie NHS Foundation Trust and Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Sciences Centre, UK.
| | | |
Collapse
|
16
|
Hamamoto Y, Inata H, Sodeoka N, Nakayama S, Tsuruoka S, Takeda H, Manabe T, Mochizuki T, Umeda M. Observation of intrafraction prostate displacement through the course of conventionally fractionated radiotherapy for prostate cancer. Jpn J Radiol 2015; 33:187-93. [DOI: 10.1007/s11604-015-0396-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2014] [Accepted: 01/21/2015] [Indexed: 11/28/2022]
|