1
|
Yan Y, Liu Y, Li T, Liang Q, Thakur A, Zhang K, Liu W, Xu Z, Xu Y. Functional roles of magnetic nanoparticles for the identification of metastatic lymph nodes in cancer patients. J Nanobiotechnology 2023; 21:337. [PMID: 37735449 PMCID: PMC10512638 DOI: 10.1186/s12951-023-02100-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 09/08/2023] [Indexed: 09/23/2023] Open
Abstract
Staging lymph nodes (LN) is crucial in diagnosing and treating cancer metastasis. Biotechnologies for the specific localization of metastatic lymph nodes (MLNs) have attracted significant attention to efficiently define tumor metastases. Bioimaging modalities, particularly magnetic nanoparticles (MNPs) such as iron oxide nanoparticles, have emerged as promising tools in cancer bioimaging, with great potential for use in the preoperative and intraoperative tracking of MLNs. As radiation-free magnetic resonance imaging (MRI) probes, MNPs can serve as alternative MRI contrast agents, offering improved accuracy and biological safety for nodal staging in cancer patients. Although MNPs' application is still in its initial stages, exploring their underlying mechanisms can enhance the sensitivity and multifunctionality of lymph node mapping. This review focuses on the feasibility and current application status of MNPs for imaging metastatic nodules in preclinical and clinical development. Furthermore, exploring novel and promising MNP-based strategies with controllable characteristics could lead to a more precise treatment of metastatic cancer patients.
Collapse
Affiliation(s)
- Yuanliang Yan
- Department of Pharmacy, Xiangya Hospital, Central South University, 410008, Changsha, Hunan, China
| | - Yuanhong Liu
- Department of Pharmacy, Xiangya Hospital, Central South University, 410008, Changsha, Hunan, China
| | - Tongfei Li
- Hubei Key Laboratory of Embryonic Stem Cell Research, School of Basic Medical Sciences, Hubei University of Medicine, 442000, Shiyan, Hubei, China
| | - Qiuju Liang
- Department of Pharmacy, Xiangya Hospital, Central South University, 410008, Changsha, Hunan, China
| | - Abhimanyu Thakur
- Pritzker School of Molecular Engineering, Ben May Department for Cancer Research, University of Chicago, 60637, Chicago, IL, USA
| | - Kui Zhang
- Pritzker School of Molecular Engineering, Ben May Department for Cancer Research, University of Chicago, 60637, Chicago, IL, USA
| | - Wei Liu
- Department of Pathology, Xiangya Hospital, Central South University, 410008, Changsha, Hunan, China
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, 410008, Changsha, Hunan, China
| | - Zhijie Xu
- Department of Pathology, Xiangya Hospital, Central South University, 410008, Changsha, Hunan, China.
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, 410008, Changsha, Hunan, China.
| | - Yuzhen Xu
- Department of Rehabilitation, The Second Affiliated Hospital of Shandong First Medical University, 271000, Taian, Shandong, China.
| |
Collapse
|
2
|
Martinez-Movilla A, Mix M, Torres-Espallardo I, Teijeiro E, Bello P, Baltas D, Martí-Bonmatí L, Carles M. Comparison of protocols with respiratory-gated (4D) motion compensation in PET/CT: open-source package for quantification of phantom image quality. EJNMMI Phys 2022; 9:80. [PMID: 36394640 PMCID: PMC9672236 DOI: 10.1186/s40658-022-00509-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 10/31/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Patient's breathing affects the quality of chest images acquired with positron emission tomography/computed tomography (PET/CT) studies. Movement correction is required to optimize PET quantification in clinical settings. We present a reproducible methodology to compare the impact of different movement compensation protocols on PET image quality. Static phantom images were set as reference values, and recovery coefficients (RCs) were calculated from motion compensated images for the phantoms in respiratory movement. Image quality was evaluated in terms of: (1) volume accuracy (VA) with the NEMA phantom; (2) concentration accuracy (CA) by six refillable inserts within the electron density CIRS phantom; and (3) spatial resolution (R) with the Jaszczak phantom. Three different respiratory patterns were applied to the phantoms. We developed an open-source package to automatically analyze VA, CA and R. We compared 10 different movement compensation protocols available in the Philips Gemini TF-64 PET/CT (4-, 6-, 8- and 10-time bins, 20%-, 30%-, 40%-window width in Inhale and Exhale). RESULTS The homemade package provided RC values for VA, CA and R of 102 PET images in less than 5 min. Results of the comparison of the 10 different protocols demonstrated the feasibility of the proposed method for quantifying the variations observed qualitatively. Overall, prospective protocols showed better motion compensation than retrospective. The best performance was obtained for the protocol Exhale 30% (0.3 s after maximum Exhale position and window width of 30%) with RC[Formula: see text], RC[Formula: see text] and RC[Formula: see text]. Among retrospective protocols, 8 Phase protocol showed the best performance. CONCLUSION We provided an open-source package able to automatically evaluate the impact of motion compensation methods on PET image quality. A setup based on commonly available experimental phantoms is recommended. Its application for the comparison of 10 time-based approaches showed that Exhale 30% protocol had the best performance. The proposed framework is not specific to the phantoms and protocols presented on this study.
Collapse
Affiliation(s)
- Andrea Martinez-Movilla
- Biomedical Imaging Research Group (GIBI230-PREBI) and Imaging La Fe node at Distributed Network for Biomedical Imaging (ReDIB), Unique Scientific and Technical Infrastructures (ICTS), La Fe Health Research Institute, Valencia, Spain
| | - Michael Mix
- Department of Nuclear Medicine, University Medical Center Freiburg, Faculty of Medicine, 79106, Freiburg, Germany
| | - Irene Torres-Espallardo
- Department of Nuclear Medicine, Medical Imaging Clinical Area, La Fe University and Polytechnic Hospital, 46026, Valencia, Spain
| | - Elena Teijeiro
- Department of Nuclear Medicine, Medical Imaging Clinical Area, La Fe University and Polytechnic Hospital, 46026, Valencia, Spain
| | - Pilar Bello
- Department of Nuclear Medicine, Medical Imaging Clinical Area, La Fe University and Polytechnic Hospital, 46026, Valencia, Spain
| | - Dimos Baltas
- Department of Radiation Oncology, Division of Medical Physics, University Medical Center Freiburg, Faculty of Medicine, 79106, Freiburg, Germany.,German Cancer Consortium (DKTK), Partner Site Freiburg, Germany
| | - Luis Martí-Bonmatí
- Biomedical Imaging Research Group (GIBI230-PREBI) and Imaging La Fe node at Distributed Network for Biomedical Imaging (ReDIB), Unique Scientific and Technical Infrastructures (ICTS), La Fe Health Research Institute, Valencia, Spain
| | - Montserrat Carles
- Biomedical Imaging Research Group (GIBI230-PREBI) and Imaging La Fe node at Distributed Network for Biomedical Imaging (ReDIB), Unique Scientific and Technical Infrastructures (ICTS), La Fe Health Research Institute, Valencia, Spain.
| |
Collapse
|
3
|
Hapdey S, Dubray B, Chastan M, Thureau S, Gouel P, Edet-Sanson A, Becker S, Vera P, Bouyeure-Petit AC. Respiratory gated multistatic PET reconstructions to delineate radiotherapy target volume in patients with mobile lung tumors. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2022; 66:171-178. [PMID: 31922369 DOI: 10.23736/s1824-4785.19.03183-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
BACKGROUND PET-CT with 18F-FDG or other radiopharmaceuticals is a recommended tool to help the delineation of lung cancers candidate to radiotherapy. The motion artifacts caused by respiratory movements are reduced by 4D acquisitions. We introduced an extended reconstruction algorithm (multiple reconstruct register and average [multi-RRA]) which requires much shorter acquisition times than standard 4D PET-CT. Our aim was to evaluate the interest on multi-RRA images as an alternative of 3D and 4D PET-CT for the delineation of lung lesion. METHODS PET acquisitions synchronized to the respiratory signal were obtained in 18 patients with mobile lung tumors. We compared the tumor volumes delineated on Multi-RRA images to 3D and 4D PET-CT, considering the 4D CT as a reference. The tumor volumes were delineated and compared with topologic similarity indexes (Dice, Jaccard and overlap). RESULTS Twenty tumors were delineated. The volumes delineated with multi-RRA and 4D PET were not significantly different (mean difference of 0.2±0.7 mL). Comparison by pairs (Tukey-Kramer test) showed that 3D-PET volumes were significantly smaller than 4D-PET and multi-RRA volumes (P<0.001). Topologic similarity indexes with 4D-PET were slightly statistically higher with multi-RRA than with 3D-PET (Dice and Jaccard) or 4D-CT (Dice, Jaccard and Overlap). CONCLUSIONS The tumor volumes delineated on multi-RRA are similar to the volumes obtained with 4D PET, with shorter acquisition time.
Collapse
Affiliation(s)
- Sebastien Hapdey
- Department of Nuclear Medicine, Henri Becquerel Cancer Center, Rouen, France -
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France -
| | - Bernard Dubray
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France
- Department of Radiotherapy, Henri Becquerel Cancer Center, Rouen, France
| | - Mathieu Chastan
- Department of Nuclear Medicine, Henri Becquerel Cancer Center, Rouen, France
| | - Sebastien Thureau
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France
- Department of Radiotherapy, Henri Becquerel Cancer Center, Rouen, France
| | - Pierrick Gouel
- Department of Nuclear Medicine, Henri Becquerel Cancer Center, Rouen, France
| | - Agathe Edet-Sanson
- Department of Nuclear Medicine, Henri Becquerel Cancer Center, Rouen, France
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France
| | - Stéphanie Becker
- Department of Nuclear Medicine, Henri Becquerel Cancer Center, Rouen, France
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France
| | - Pierre Vera
- Department of Nuclear Medicine, Henri Becquerel Cancer Center, Rouen, France
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France
| | | |
Collapse
|
4
|
Kim JS, Park CR, Yoon SH, Lee JA, Kim TY, Yang HJ. Improvement of image quality using amplitude-based respiratory gating in PET-computed tomography scanning. Nucl Med Commun 2021; 42:553-565. [PMID: 33625179 DOI: 10.1097/mnm.0000000000001368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES This study sought to provide data supporting the expanded clinical use of respiratory gating by assessing the diagnostic accuracy of breathing motion correction using amplitude-based respiratory gating. METHODS A respiratory movement tracking device was attached to a PET-computed tomography scanner, and images were obtained in respiratory gating mode using a motion phantom that was capable of sensing vertical motion. Specifically, after setting amplitude changes and intervals according to the movement cycle using a total of nine combinations of three waveforms and three amplitude ranges, respiratory motion-corrected images were reconstructed using the filtered back projection method. After defining areas of interest in the acquired images in the same image planes, statistical analyses were performed to compare differences in standardized uptake value (SUV), lesion volume, full width at half maximum (FWHM), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). RESULTS SUVmax increased by 89.9%, and lesion volume decreased by 27.9%. Full width at half maximum decreased by 53.9%, signal-to-noise ratio increased by 11% and contrast-to-noise ratio increased by 16.3%. Optimal results were obtained when using a rest waveform and 35% duty cycle, in which the change in amplitude in the respiratory phase signal was low, and a constant level of long breaths was maintained. CONCLUSIONS These results demonstrate that respiratory-gated PET-CT imaging can be used to accurately correct for SUV changes and image distortion caused by respiratory motion, thereby providing excellent imaging information and quality.
Collapse
Affiliation(s)
- Jung-Soo Kim
- Department of Radiological Technology, Dongnam Health University, Suwon
- Department of Biomedical Science, The Korea University, Sejong
| | - Chan-Rok Park
- Department of Biomedical Science, The Korea University, Sejong
- Department of Nuclear Medicine, Seoul National University Hospital, Seoul
| | - Seok-Hwan Yoon
- Department of Biomedical Science, The Korea University, Sejong
- Department of Nuclear Medicine, Seoul National University Hospital, Seoul
| | - Joo-Ah Lee
- Department of Biomedical Science, The Korea University, Sejong
- Department of Radiation Oncology, Catholic University Incheon St. Mary's Hospital, Incheon
| | - Tae-Yoon Kim
- Department of Radiation Oncology, Catholic University Incheon St. Mary's Hospital, Incheon
- Department of Radiation Oncology, National Cancer Center, Goyang
| | - Hyung-Jin Yang
- Department of Radiation Oncology, Catholic University Incheon St. Mary's Hospital, Incheon
- Department of Physics, The Korea University, Sejong, Korea
| |
Collapse
|
5
|
Zeng J, Bowen SR. Treatment Intensification in Locally Advanced/Unresectable NSCLC Through Combined Modality Treatment and Precision Dose Escalation. Semin Radiat Oncol 2021; 31:105-111. [PMID: 33610266 DOI: 10.1016/j.semradonc.2020.11.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The best survival for patients with unresectable, locally advanced NSCLC is currently achieved through concurrent chemoradiation followed by durvalumab for a year. Despite the best standard of care treatment, the majority of patients still develop disease recurrence, which could be distant and/or local. Trials continue to try and improve outcomes for patients with unresectable NSCLC, typically through treatment intensification, with the addition of more systemic agents, or more radiation dose to the tumor. Although RTOG 0617 showed that uniform dose escalation across an unselected population of patients undergoing chemoradiation is not beneficial, efforts continue to select patients and tumor subsets that are likely to benefit from dose escalation. This review describes some of the ongoing therapeutic trials in unresectable NSCLC, with an emphasis on quantitative imaging and precision radiation dose escalation.
Collapse
Affiliation(s)
- Jing Zeng
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA.
| | - Stephen R Bowen
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA; Department of Radiology, University of Washington School of Medicine, Seattle, WA
| |
Collapse
|
6
|
Keikhai Farzaneh MJ, Momennezhad M, Naseri S. Gated Radiotherapy Development and its Expansion. J Biomed Phys Eng 2021; 11:239-256. [PMID: 33937130 PMCID: PMC8064130 DOI: 10.31661/jbpe.v0i0.948] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Accepted: 07/14/2018] [Indexed: 12/25/2022]
Abstract
One of the most important challenges in treatment of patients with cancerous tumors of chest and abdominal areas is organ movement. The delivery of treatment radiation doses to tumor tissue is a challenging matter while protecting healthy and radio sensitive tissues. Since the movement of organs due to respiration causes a discrepancy in the middle of planned and delivered dose distributions. The moderation in the fatalistic effect of intra-fractional target travel on the radiation therapy correctness is necessary for cutting-edge methods of motion remote monitoring and cancerous growth irradiancy. Tracking respiratory milling and implementation of breath-hold techniques by respiratory gating systems have been used for compensation of respiratory motion negative effects. Therefore, these systems help us to deliver precise treatments and also protect healthy and critical organs. It seems aspiration should be kept under observation all over treatment period employing tracking seed markers (e.g. fiducials), skin surface scanners (e.g. camera and laser monitoring systems) and aspiration detectors (e.g. spirometers). However, these systems are not readily available for most radiotherapy centers around the word. It is believed that providing and expanding the required equipment, gated radiotherapy will be a routine technique for treatment of chest and abdominal tumors in all clinical radiotherapy centers in the world by considering benefits of respiratory gating techniques in increasing efficiency of patient treatment in the near future. This review explains the different technologies and systems as well as some strategies available for motion management in radiotherapy centers.
Collapse
Affiliation(s)
- Mohammad Javad Keikhai Farzaneh
- PhD, Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- PhD, Department of Medical Physics, Faculty of Medicine, Zahedan University of Medical Sciences, Zahedan, Iran
| | - Mehdi Momennezhad
- PhD, Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- PhD, Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Shahrokh Naseri
- PhD, Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- PhD, Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
7
|
Carles M, Fechter T, Radicioni G, Schimek-Jasch T, Adebahr S, Zamboglou C, Nicolay NH, Martí-Bonmatí L, Nestle U, Grosu AL, Baltas D, Mix M, Gkika E. FDG-PET Radiomics for Response Monitoring in Non-Small-Cell Lung Cancer Treated with Radiation Therapy. Cancers (Basel) 2021; 13:cancers13040814. [PMID: 33672052 PMCID: PMC7919471 DOI: 10.3390/cancers13040814] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 02/05/2021] [Accepted: 02/07/2021] [Indexed: 02/06/2023] Open
Abstract
Simple Summary In this study, we strive to identify clinically relevant image feature (IF) changes during chemoradiation in patients with non-small-cell lung cancer (NSCLC) to be able to predict tumor responses in an early stage of treatment. All patients underwent static (3D) and respiratory-gated 4D PET/CT scans before treatment and a 3D scan during or after treatment. Our proposed method rejects IF changes due to intrinsic variability such as noise, resolution and movement through breathing. The IF variability observed across 4D PET is employed as a patient individualized normalization factor to emphasize statistically relevant IF changes during treatment. Abstract The aim of this study is to identify clinically relevant image feature (IF) changes during chemoradiation and evaluate their efficacy in predicting treatment response. Patients with non-small-cell lung cancer (NSCLC) were enrolled in two prospective trials (STRIPE, PET-Plan). We evaluated 48 patients who underwent static (3D) and retrospectively-respiratory-gated 4D PET/CT scans before treatment and a 3D scan during or after treatment. Our proposed method rejects IF changes due to intrinsic variability. The IF variability observed across 4D PET is employed as a patient individualized normalization factor to emphasize statistically relevant IF changes during treatment. Predictions of overall survival (OS), local recurrence (LR) and distant metastasis (DM) were evaluated. From 135 IFs, only 17 satisfied the required criteria of being normally distributed across 4D PET and robust between 3D and 4D images. Changes during treatment in the area-under-the-curve of the cumulative standard-uptake-value histogram (δAUCCSH) within primary tumor discriminated (AUC = 0.87, Specificity = 0.78) patients with and without LR. The resulted prognostic model was validated with a different segmentation method (AUC = 0.83) and in a different patient cohort (AUC = 0.63). The quantification of tumor FDG heterogeneity by δAUCCSH during chemoradiation correlated with the incidence of local recurrence and might be recommended for monitoring treatment response in patients with NSCLC.
Collapse
Affiliation(s)
- Montserrat Carles
- Department of Radiation Oncology, Division of Medical Physics, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (T.F.); (D.B.)
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
- La Fe Health Research Institute, Biomedical Imaging Research Group (GIBI230-PREBI) and Imaging La Fe Node at Distributed Network for Biomedical Imaging (ReDIB) Unique Scientific and Technical Infrastructures (ICTS), 46026 Valencia, Spain;
- Correspondence:
| | - Tobias Fechter
- Department of Radiation Oncology, Division of Medical Physics, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (T.F.); (D.B.)
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
| | - Gianluca Radicioni
- Department of Radiation Oncology, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (G.R.); (T.S.-J.)
| | - Tanja Schimek-Jasch
- Department of Radiation Oncology, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (G.R.); (T.S.-J.)
| | - Sonja Adebahr
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
- Department of Radiation Oncology, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (G.R.); (T.S.-J.)
| | - Constantinos Zamboglou
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
- Department of Radiation Oncology, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (G.R.); (T.S.-J.)
| | - Nils H. Nicolay
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
- Department of Radiation Oncology, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (G.R.); (T.S.-J.)
| | - Luis Martí-Bonmatí
- La Fe Health Research Institute, Biomedical Imaging Research Group (GIBI230-PREBI) and Imaging La Fe Node at Distributed Network for Biomedical Imaging (ReDIB) Unique Scientific and Technical Infrastructures (ICTS), 46026 Valencia, Spain;
| | - Ursula Nestle
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
- Department of Radiation Oncology, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (G.R.); (T.S.-J.)
- Department of Radiation Oncology, Kliniken Maria Hilf, GmbH Moenchengladbach, 41063 Moechengladbach, Germany
| | - Anca L. Grosu
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
- Department of Radiation Oncology, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (G.R.); (T.S.-J.)
| | - Dimos Baltas
- Department of Radiation Oncology, Division of Medical Physics, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (T.F.); (D.B.)
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
| | - Michael Mix
- Department of Nuclear Medicine, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany;
| | - Eleni Gkika
- German Cancer Consortium (DKTK), German Cancer Research Center (DKFZ), Partner Site Freiburg of the German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany; (S.A.); (C.Z.); (N.H.N.); (U.N.); (A.L.G.); (E.G.)
- Department of Radiation Oncology, University Medical Center Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; (G.R.); (T.S.-J.)
| |
Collapse
|
8
|
Kim JH, Nguyen DT, Huang CY, Fuangrod T, Caillet V, O’Brien R, Poulsen P, Booth J, Keall P. Quantifying the accuracy and precision of a novel real-time 6 degree-of-freedom kilovoltage intrafraction monitoring (KIM) target tracking system. ACTA ACUST UNITED AC 2017. [DOI: 10.1088/1361-6560/aa6ed7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
9
|
Ali I, Alsbou N, Taguenang JM, Ahmad S. Quantitative evaluation by measurement and modeling of the variations in dose distributions deposited in mobile targets. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2017; 25:XST16223. [PMID: 28269814 DOI: 10.3233/xst-16223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The objective of this study is to quantitatively evaluate variations of dose distributions deposited in mobile target by measurement and modeling. The effects of variation in dose distribution induced by motion on tumor dose coverage and sparing of normal tissues were investigated quantitatively. The dose distributions with motion artifacts were modeled considering different motion patterns that include (a) motion with constant speed and (b) sinusoidal motion. The model predictions of the dose distributions with motion artifacts were verified with measurement where the dose distributions from various plans that included three-dimensional conformal and intensity-modulated fields were measured with a multiple-diode-array detector (MapCheck2), which was mounted on a mobile platform that moves with adjustable motion parameters. For each plan, the dose distributions were then measured with MapCHECK2 using different motion amplitudes from 0-25 mm. In addition, mathematical modeling was developed to predict the variations in the dose distributions and their dependence on the motion parameters that included amplitude, frequency and phase for sinusoidal motions. The dose distributions varied with motion and depended on the motion pattern particularly the sinusoidal motion, which spread out along the direction of motion. Study results showed that in the dose region between isocenter and the 50% isodose line, the dose profile decreased with increase of the motion amplitude. As the range of motion became larger than the field length along the direction of motion, the dose profiles changes overall including the central axis dose and 50% isodose line. If the total dose was delivered over a time much longer than the periodic time of motion, variations in motion frequency and phase do not affect the dose profiles. As a result, the motion dose modeling developed in this study provided quantitative characterization of variation in the dose distributions induced by motion, which can be employed in radiation therapy to quantitatively determine the margins needed for treatment planning considering dose spillage to normal tissue.
Collapse
Affiliation(s)
- Imad Ali
- Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | - Nesreen Alsbou
- Department of Engineering and Physics, University of Central Oklahoma, University Drive, Edmond, OK, USA
| | | | - Salahuddin Ahmad
- Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| |
Collapse
|
10
|
Thureau S, Hapdey S, Vera P. [Role of functional imaging in the definition of target volumes for lung cancer radiotherapy]. Cancer Radiother 2016; 20:699-704. [PMID: 27614514 DOI: 10.1016/j.canrad.2016.08.121] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Accepted: 08/01/2016] [Indexed: 12/23/2022]
Abstract
Functional imaging with positron emission tomography (PET) is interesting to optimize lung radiotherapy planning, and probably to deliver a heterogeneous dose or adapt the radiation dose during treatment. Only fluorodeoxyglucose (FDG) PET-computed tomography (CT) is validated for staging lung cancer and planning radiotherapy. The optimal segmentation methods remain to be defined as well as the interest of "dose painting" from pre-treatment PET (metabolism: FDG) or hypoxia (fluoromisonidazole: FMISO) and the interest of replanning based on pertherapeutic PET.
Collapse
Affiliation(s)
- S Thureau
- Département de médecine nucléaire, centre de lutte contre le cancer Henri-Becquerel, rue d'Amiens, 76000 Rouen, France; Département de radiothérapie et de physique médicale, centre de lutte contre le cancer Henri-Becquerel, rue d'Amiens, 76000 Rouen, France; Laboratoire QuantIF, EA4108-Litis, FR CNRS 3638, 1, rue d'Amiens, 76000 Rouen, France.
| | - S Hapdey
- Département de médecine nucléaire, centre de lutte contre le cancer Henri-Becquerel, rue d'Amiens, 76000 Rouen, France; Laboratoire QuantIF, EA4108-Litis, FR CNRS 3638, 1, rue d'Amiens, 76000 Rouen, France
| | - P Vera
- Département de médecine nucléaire, centre de lutte contre le cancer Henri-Becquerel, rue d'Amiens, 76000 Rouen, France; Laboratoire QuantIF, EA4108-Litis, FR CNRS 3638, 1, rue d'Amiens, 76000 Rouen, France
| |
Collapse
|
11
|
Jeraj R, Bradshaw T, Simončič U. Molecular Imaging to Plan Radiotherapy and Evaluate Its Efficacy. J Nucl Med 2015; 56:1752-65. [PMID: 26383148 DOI: 10.2967/jnumed.114.141424] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Accepted: 09/08/2015] [Indexed: 12/25/2022] Open
Abstract
Molecular imaging plays a central role in the management of radiation oncology patients. Specific uses of imaging, particularly to plan radiotherapy and assess its efficacy, require an additional level of reproducibility and image quality beyond what is required for diagnostic imaging. Specific requirements include proper patient preparation, adequate technologist training, careful imaging protocol design, reliable scanner technology, reproducible software algorithms, and reliable data analysis methods. As uncertainty in target definition is arguably the greatest challenge facing radiation oncology, the greatest impact that molecular imaging can have may be in the reduction of interobserver variability in target volume delineation and in providing greater conformity between target volume boundaries and true tumor boundaries. Several automatic and semiautomatic contouring methods based on molecular imaging are available but still need sufficient validation to be widely adopted. Biologically conformal radiotherapy (dose painting) based on molecular imaging-assessed tumor heterogeneity is being investigated, but many challenges remain to fully exploring its potential. Molecular imaging also plays increasingly important roles in both early (during treatment) and late (after treatment) response assessment as both a predictive and a prognostic tool. Because of potentially confounding effects of radiation-induced inflammation, treatment response assessment requires careful interpretation. Although molecular imaging is already strongly embedded in radiotherapy, the path to widespread and all-inclusive use is still long. The lack of solid clinical evidence is the main impediment to broader use. Recommendations for practicing physicians are still rather scarce. (18)F-FDG PET/CT remains the main molecular imaging modality in radiation oncology applications. Although other molecular imaging options (e.g., proliferation imaging) are becoming more common, their widespread use is limited by lack of tracer availability and inadequate reimbursement models. With the increasing presence of molecular imaging in radiation oncology, special emphasis should be placed on adequate training of radiation oncology personnel to understand the potential, and particularly the limitations, of quantitative molecular imaging applications. Similarly, radiologists and nuclear medicine specialists should be sensitized to the special need of the radiation oncologist in terms of quantification and reproducibility. Furthermore, strong collaboration between radiation oncology, nuclear medicine/radiology, and medical physics teams is necessary, as optimal and safe use of molecular imaging can be ensured only within appropriate interdisciplinary teams.
Collapse
Affiliation(s)
- Robert Jeraj
- School of Medicine and Public Health, University of Wisconsin, Madison, Wisconsin; and Faculty of Mathematics and Physics, University of Ljubljana, Ljubljana, Slovenia
| | - Tyler Bradshaw
- School of Medicine and Public Health, University of Wisconsin, Madison, Wisconsin; and
| | - Urban Simončič
- Faculty of Mathematics and Physics, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
12
|
Chao M, Yuan Y, Sheu RD, Wang K, Rosenzweig KE, Lo YC. A Feasibility Study of Tumor Motion Estimate With Regional Deformable Registration Method for 4-Dimensional Radiation Therapy of Lung Cancer. Technol Cancer Res Treat 2015; 15:NP8-NP16. [PMID: 26294654 DOI: 10.1177/1533034615600569] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Accepted: 07/22/2015] [Indexed: 11/15/2022] Open
Abstract
This study aims to employ 4-dimensional computed tomography to quantify intrafractional tumor motion for patients with lung cancer to improve target localization in radiation therapy. A multistage regional deformable registration was implemented to calculate the excursion of gross tumor volume (GTV) during a breathing cycle. GTV was initially delineated on 0% phase of 4-dimensional computed tomography manually, and a subregion with 20 mm margin supplemented to GTV was generated with Eclipse treatment planning system (Varian Medical Systems, Palo Alto, California). The structures, together with the 4-dimensional computed tomography set, were exported into an in-house software, with which a 3-stage B-spline deformable registration was carried out to map the subregion and warp GTV contour to other breathing phases. The center of mass of the GTV was computed using the contours, and the tumor motion was appraised as the excursion of the center of mass between 0% phase and other phases. Application of the algorithm to the 10 patients showed that clinically satisfactory outcomes were achievable with a spatial accuracy around 2 mm for GTV contour propagation between adjacent phases and 3 mm between opposite phases. The tumor excursion was determined in the vast range of 1 mm through 1.6 cm, depending on the tumor location and tumor size. Compared to the traditional whole image-based registration, the regional method was found computationally a factor of 5 more efficient. The proposed technique has demonstrated its capability in extracting thoracic tumor motion and should find its application in 4-dimensional radiation therapy in the future to maximally utilize the available spatial-temporal information.
Collapse
Affiliation(s)
- Ming Chao
- Department of Radiation Oncology, Mount Sinai Medical Center, New York, NY, USA
| | - Yading Yuan
- Department of Radiation Oncology, Mount Sinai Medical Center, New York, NY, USA
| | - Ren-Dih Sheu
- Department of Radiation Oncology, Mount Sinai Medical Center, New York, NY, USA
| | - Kelin Wang
- Division of Radiation Oncology, Pennsylvania State Hershey Cancer Institute, Hershey, PA, USA
| | | | - Yeh-Chi Lo
- Department of Radiation Oncology, Mount Sinai Medical Center, New York, NY, USA
| |
Collapse
|
13
|
Jaffray DA, Chung C, Coolens C, Foltz W, Keller H, Menard C, Milosevic M, Publicover J, Yeung I. Quantitative Imaging in Radiation Oncology: An Emerging Science and Clinical Service. Semin Radiat Oncol 2015; 25:292-304. [PMID: 26384277 DOI: 10.1016/j.semradonc.2015.05.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Radiation oncology has long required quantitative imaging approaches for the safe and effective delivery of radiation therapy. The past 10 years has seen a remarkable expansion in the variety of novel imaging signals and analyses that are starting to contribute to the prescription and design of the radiation treatment plan. These include a rapid increase in the use of magnetic resonance imaging, development of contrast-enhanced imaging techniques, integration of fluorinated deoxyglucose-positron emission tomography, evaluation of hypoxia imaging techniques, and numerous others. These are reviewed with an effort to highlight challenges related to quantification and reproducibility. In addition, several of the emerging applications of these imaging approaches are also highlighted. Finally, the growing community of support for establishing quantitative imaging approaches as we move toward clinical evaluation is summarized and the need for a clinical service in support of the clinical science and delivery of care is proposed.
Collapse
Affiliation(s)
- David Anthony Jaffray
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.
| | - Caroline Chung
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Catherine Coolens
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Warren Foltz
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Harald Keller
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Cynthia Menard
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Michael Milosevic
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Julia Publicover
- TECHNA Institute/University Health Network, Toronto, Ontario, Canada
| | - Ivan Yeung
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada; TECHNA Institute/University Health Network, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
14
|
Bowen SR, Nyflot MJ, Herrmann C, Groh CM, Meyer J, Wollenweber SD, Stearns CW, Kinahan PE, Sandison GA. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study. Phys Med Biol 2015; 60:3731-46. [PMID: 25884892 DOI: 10.1088/0031-9155/60/9/3731] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [(18)F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.
Collapse
Affiliation(s)
- S R Bowen
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA, USA. Department of Radiology, University of Washington School of Medicine, Seattle, WA, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Didierlaurent D, Jaudet C, Ribes S, Batatia H, Dierickx LO, Zerdoud S, Brillouet S, Weyts K, Courbon F, Caselles O. Comparison of an alternative and existing binning methods to reduce the acquisition duration of 4D PET/CT. Med Phys 2014; 41:112503. [DOI: 10.1118/1.4897612] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
16
|
Bowen SR, Pierce LA, Alessio AM, Liu C, Wollenweber SD, Stearns CW, Kinahan PE. Assessment of patient selection criteria for quantitative imaging with respiratory-gated positron emission tomography. J Med Imaging (Bellingham) 2014; 1:026001. [PMID: 26158039 DOI: 10.1117/1.jmi.1.2.026001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Revised: 09/03/2014] [Accepted: 09/03/2014] [Indexed: 12/25/2022] Open
Abstract
The objective of this investigation was to propose techniques for determining which patients are likely to benefit from quantitative respiratory-gated imaging by correlating respiratory patterns to changes in positron emission tomography (PET) metrics. Twenty-six lung and liver cancer patients underwent PET/computed tomography exams with recorded chest/abdominal displacements. Static and adaptive amplitude-gated [[Formula: see text]]fluoro-D-glucose (FDG) PET images were generated from list-mode acquisitions. Patients were grouped by respiratory pattern, lesion location, or degree of lesion attachment to anatomical structures. Respiratory pattern metrics were calculated during time intervals corresponding to PET field of views over lesions of interest. FDG PET images were quantified by lesion maximum standardized uptake value ([Formula: see text]). Relative changes in [Formula: see text] between static and gated PET images were tested for association to respiratory pattern metrics. Lower lung lesions and liver lesions had significantly higher changes in [Formula: see text] than upper lung lesions (14 versus 3%, [Formula: see text]). Correlation was highest ([Formula: see text], [Formula: see text], [Formula: see text]) between changes in [Formula: see text] and nonstandard respiratory pattern metrics. Lesion location had a significant impact on changes in PET quantification due to respiratory gating. Respiratory pattern metrics were correlated to changes in [Formula: see text], though sample size limited statistical power. Validation in larger cohorts may enable selection of patients prior to acquisition who would benefit from respiratory-gated PET imaging.
Collapse
Affiliation(s)
- Stephen R Bowen
- University of Washington School of Medicine , Department of Radiation Oncology, 1959 NE Pacific St, Seattle, Washington 98195, United States ; University of Washington School of Medicine , Department of Radiology, 1959 NE Pacific St, Seattle, Washington 98195, United States
| | - Larry A Pierce
- University of Washington School of Medicine , Department of Radiology, 1959 NE Pacific St, Seattle, Washington 98195, United States
| | - Adam M Alessio
- University of Washington School of Medicine , Department of Radiology, 1959 NE Pacific St, Seattle, Washington 98195, United States
| | - Chi Liu
- Yale University School of Medicine , Department of Diagnostic Radiology, New Haven, Connecticut 06510, United States
| | | | | | - Paul E Kinahan
- University of Washington School of Medicine , Department of Radiology, 1959 NE Pacific St, Seattle, Washington 98195, United States
| |
Collapse
|
17
|
Abstract
Combined PET/computed tomography (CT) is of value in cancer diagnosis, follow-up, and treatment planning. For cancers located in the thorax or abdomen, the patient’s breathing causes artifacts and errors in PET and CT images. Many different approaches for artifact avoidance or correction have been developed; most are based on gated acquisition and synchronization between the respiratory signal and PET acquisition. The respiratory signal is usually produced by an external sensor that tracks a physiological characteristic related to the patient’s breathing. Respiratory gating is a compensation technique in which time or amplitude binning is used to exclude the motion in reconstructed PET images. Although this technique is performed in routine clinical practice, it fails to adequately correct for respiratory motion because each gate can mix several tissue positions. Researchers have suggested either selecting PET events from gated acquisitions or performing several PET acquisitions (corresponding to a breath-hold CT position). However, the PET acquisition time must be increased if adequate counting statistics are to be obtained in the different gates after binning. Hence, other researchers have assessed correction techniques that take account of all the counting statistics (without increasing the acquisition duration) and integrate motion information before, during, or after the reconstruction process. Here, we provide an overview of how motion is managed to overcome respiratory motion in PET/CT images.
Collapse
|
18
|
Sieren JC, Meyerholz DK, Wang XJ, Davis BT, Newell JD, Hammond E, Rohret JA, Rohret FA, Struzynski JT, Goeken JA, Naumann PW, Leidinger MR, Taghiyev A, Van Rheeden R, Hagen J, Darbro BW, Quelle DE, Rogers CS. Development and translational imaging of a TP53 porcine tumorigenesis model. J Clin Invest 2014; 124:4052-66. [PMID: 25105366 DOI: 10.1172/jci75447] [Citation(s) in RCA: 72] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2014] [Accepted: 06/19/2014] [Indexed: 01/03/2023] Open
Abstract
Cancer is the second deadliest disease in the United States, necessitating improvements in tumor diagnosis and treatment. Current model systems of cancer are informative, but translating promising imaging approaches and therapies to clinical practice has been challenging. In particular, the lack of a large-animal model that accurately mimics human cancer has been a major barrier to the development of effective diagnostic tools along with surgical and therapeutic interventions. Here, we developed a genetically modified porcine model of cancer in which animals express a mutation in TP53 (which encodes p53) that is orthologous to one commonly found in humans (R175H in people, R167H in pigs). TP53(R167H/R167H) mutant pigs primarily developed lymphomas and osteogenic tumors, recapitulating the tumor types observed in mice and humans expressing orthologous TP53 mutant alleles. CT and MRI imaging data effectively detected developing tumors, which were validated by histopathological evaluation after necropsy. Molecular genetic analyses confirmed that these animals expressed the R167H mutant p53, and evaluation of tumors revealed characteristic chromosomal instability. Together, these results demonstrated that TP53(R167H/R167H) pigs represent a large-animal tumor model that replicates the human condition. Our data further suggest that this model will be uniquely suited for developing clinically relevant, noninvasive imaging approaches to facilitate earlier detection, diagnosis, and treatment of human cancers.
Collapse
|
19
|
Wang S, Bowen SR, Chaovalitwongse WA, Sandison GA, Grabowski TJ, Kinahan PE. Respiratory trace feature analysis for the prediction of respiratory-gated PET quantification. Phys Med Biol 2014; 59:1027-45. [PMID: 24504153 DOI: 10.1088/0031-9155/59/4/1027] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The benefits of respiratory gating in quantitative PET/CT vary tremendously between individual patients. Respiratory pattern is among many patient-specific characteristics that are thought to play an important role in gating-induced imaging improvements. However, the quantitative relationship between patient-specific characteristics of respiratory pattern and improvements in quantitative accuracy from respiratory-gated PET/CT has not been well established. If such a relationship could be estimated, then patient-specific respiratory patterns could be used to prospectively select appropriate motion compensation during image acquisition on a per-patient basis. This study was undertaken to develop a novel statistical model that predicts quantitative changes in PET/CT imaging due to respiratory gating. Free-breathing static FDG-PET images without gating and respiratory-gated FDG-PET images were collected from 22 lung and liver cancer patients on a PET/CT scanner. PET imaging quality was quantified with peak standardized uptake value (SUV(peak)) over lesions of interest. Relative differences in SUV(peak) between static and gated PET images were calculated to indicate quantitative imaging changes due to gating. A comprehensive multidimensional extraction of the morphological and statistical characteristics of respiratory patterns was conducted, resulting in 16 features that characterize representative patterns of a single respiratory trace. The six most informative features were subsequently extracted using a stepwise feature selection approach. The multiple-regression model was trained and tested based on a leave-one-subject-out cross-validation. The predicted quantitative improvements in PET imaging achieved an accuracy higher than 90% using a criterion with a dynamic error-tolerance range for SUV(peak) values. The results of this study suggest that our prediction framework could be applied to determine which patients would likely benefit from respiratory motion compensation when clinicians quantitatively assess PET/CT for therapy target definition and response assessment.
Collapse
Affiliation(s)
- Shouyi Wang
- Department of Industrial and Systems Engineering, 3900 Stevens Way, Seattle, WA 98195, USA. Integrated Brain Imaging Center, 1959 NE Pacific St, Seattle, WA 98195, USA
| | | | | | | | | | | |
Collapse
|
20
|
Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: preliminary results. Eur J Nucl Med Mol Imaging 2013; 41:702-10. [DOI: 10.1007/s00259-013-2594-5] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2013] [Accepted: 10/01/2013] [Indexed: 12/25/2022]
|
21
|
Paulmurugan R, Oronsky B, Brouse CF, Reid T, Knox S, Scicinski J. Real time dynamic imaging and current targeted therapies in the war on cancer: a new paradigm. Theranostics 2013; 3:437-47. [PMID: 23781290 PMCID: PMC3677414 DOI: 10.7150/thno.5658] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2012] [Accepted: 02/28/2013] [Indexed: 12/13/2022] Open
Abstract
In biology, as every science student is made to learn, ontology recapitulates phylogeny. In medicine, however, oncology recapitulates polemology, the science of warfare: The medical establishment is transitioning from highly toxic poisons that kill rapidly dividing normal and malignant cells with little specificity to tailored therapies that target the tumors with the lethality of the therapeutic warhead. From the advent of the information age with the incorporation of high-tech intelligence, reconnaissance, and surveillance has resulted in "data fusion" where a wide range of information collected in near real-time can be used to redesign most of the treatment strategies currently used in the clinic. The medical community has begun to transition from the 'black box' of tumor therapy based solely on the clinical response to the 'glass box' of dynamic imaging designed to bring transparency to the clinical battlefield during treatment, thereby informing the therapeutic decision to 'retreat or repeat'. The tumor microenvironment is dynamic, constantly changing in response to therapeutic intervention, and therefore the therapeutic assessment must map to this variable and ever-changing landscape with dynamic and non-static imaging capabilities. The path to personalized medicine will require incorporation and integration of dynamic imaging at the bedside into clinical practice for real-time, interactive assessment of response to targeted therapies. The application of advanced real time imaging techniques along with current molecularly targeted anticancer therapies which alter cellular homeostasis and microenvironment can enhance therapeutic interventions in cancer patients and further improve the current status in clinical management of patients with advanced cancers.
Collapse
|