1
|
Correia JJ, Stafford WF, Erlandsen H, Cole JL, Premathilaka SH, Isailovic D, Dignam JD. Hydrodynamic and thermodynamic analysis of PEGylated human serum albumin. Biophys J 2024; 123:2506-2521. [PMID: 38898654 PMCID: PMC11365110 DOI: 10.1016/j.bpj.2024.06.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/31/2024] [Accepted: 06/17/2024] [Indexed: 06/21/2024] Open
Abstract
Covalent labeling of therapeutic drugs and proteins with polyethylene glycol (PEGylation) is an important modification for improving stability, solubility, and half-life. PEGylation alters protein solution behavior through its impact on thermodynamic nonideality by increasing the excluded volume, and on hydrodynamic nonideality by increasing the frictional drag. To understand PEGylation's impact, we investigated the thermodynamic and hydrodynamic properties of a model system consisting of PEGylated human serum albumin derivatives using analytical ultracentrifugation (AUC) and dynamic light scattering (DLS). We constructed PEGylated human serum albumin derivatives of single, linear 5K, 10K, 20K, and 40K PEG chains and a single branched-chain PEG of 40K (2 × 20K). Sedimentation velocity (SV) experiments were analyzed using SEDANAL direct boundary fitting to extract ideal sedimentation coefficients so, hydrodynamic nonideality ks, and thermodynamic nonideality 2BM1SV terms. These quantities allow the determination of the Stokes radius Rs, the frictional ratio f/fo, and the swollen or entrained volume Vs/v, which measure size, shape, and solvent interaction. We performed sedimentation equilibrium experiments to obtain independent measurements of thermodynamic nonideality 2BM1SE. From DLS measurements, we determined the interaction parameter, kD, the concentration dependence of the apparent diffusion coefficient, D, and from extrapolation of D to c = 0 a second estimate of Rs. Rs values derived from SV and DLS measurements and ensemble model calculations (see complementary study) are then used to show that ks + kD = theoretical 2B22M1. In contrast, experimental BM1 values from SV and sedimentation equilibrium data collectively allow for similar analysis for protein-PEG conjugates and show that ks + kD = 1.02-1.07∗BM1, rather than the widely used ks + kD = 2BM1 developed for hard spheres. The random coil behavior of PEG dominates the colloidal properties of PEG-protein conjugates and exceeds the sum of a random coil and hard-sphere volume due to excess entrained water.
Collapse
Affiliation(s)
- John J Correia
- Department of Cell & Molecular Biology, University of Miss Medical Center, Jackson, Mississippi.
| | - Walter F Stafford
- Department of Systems Biology, Harvard Medical School, Boston, Massachusetts
| | - Heidi Erlandsen
- Center for Open Research Resources and Equipment, University of Connecticut, Storrs, Connecticut
| | - James L Cole
- Department of Molecular and Cell Biology, University of Connecticut, Storrs, Connecticut
| | | | - Dragan Isailovic
- Department of Chemistry and Biochemistry, University of Toledo, Toledo, Ohio
| | - John David Dignam
- Department of Chemistry and Biochemistry, University of Toledo, Toledo, Ohio
| |
Collapse
|
2
|
Bonanno FG. Management of Hemorrhagic Shock: Physiology Approach, Timing and Strategies. J Clin Med 2022; 12:jcm12010260. [PMID: 36615060 PMCID: PMC9821021 DOI: 10.3390/jcm12010260] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/22/2022] [Accepted: 11/27/2022] [Indexed: 12/30/2022] Open
Abstract
Hemorrhagic shock (HS) management is based on a timely, rapid, definitive source control of bleeding/s and on blood loss replacement. Stopping the hemorrhage from progressing from any named and visible vessel is the main stem fundamental praxis of efficacy and effectiveness and an essential, obligatory, life-saving step. Blood loss replacement serves the purpose of preventing ischemia/reperfusion toxemia and optimizing tissue oxygenation and microcirculation dynamics. The "physiological classification of HS" dictates the timely management and suits the 'titrated hypotensive resuscitation' tactics and the 'damage control surgery' strategy. In any hypotensive but not yet critical shock, the body's response to a fluid load test determines the cut-off point between compensation and progression between the time for adopting conservative treatment and preparing for surgery or rushing to the theater for rapid bleeding source control. Up to 20% of the total blood volume is given to refill the unstressed venous return volume. In any critical level of shock where, ab initio, the patient manifests signs indicating critical physiology and impending cardiac arrest or cardiovascular accident, the balance between the life-saving reflexes stretched to the maximum and the insufficient distal perfusion (blood, oxygen, and substrates) remains in a liable and delicate equilibrium, susceptible to any minimal change or interfering variable. In a cardiac arrest by exsanguination, the core of the physiological issue remains the rapid restoration of a sufficient venous return, allowing the heart to pump it back into systemic circulation either by open massage via sternotomy or anterolateral thoracotomy or spontaneously after aorta clamping in the chest or in the abdomen at the epigastrium under extracorporeal resuscitation and induced hypothermia. This is the only way to prevent ischemic damage to the brain and the heart. This is accomplishable rapidly and efficiently only by a direct approach, which is a crush laparotomy if the bleeding is coming from an abdominal +/- lower limb site or rapid sternotomy/anterolateral thoracotomy if the bleeding is coming from a chest +/- upper limbs site. Without first stopping the bleeding and refilling the heart, any further exercise is doomed to failure. Direct source control via laparotomy/thoracotomy, with the concomitant or soon following venous refilling, are the two essential, initial life-saving steps.
Collapse
Affiliation(s)
- Fabrizio G Bonanno
- Department of Surgery, Polokwane Provincial Hospital, Cnr Hospital & Dorp Street, Polokwane 0700, South Africa
| |
Collapse
|
3
|
Meng F, Kaul D, Thangaswamy S, Bhutoria S, Gerfen G, Branch C, Intaglietta M, Acharya SA. Semisynthetic supra plasma expanders: a new class of therapeutics to improve microcircualtion in sickle cell anaemia. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2019; 47:73-82. [DOI: 10.1080/21691401.2018.1543194] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Fantao Meng
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY, USA
- Laboratory of Biochemistry and Vascular Biology, Center for Biologics Evaluation and Research, Food and Drug Administration, Silver Spring, MA, USA
| | - Dhananjaya Kaul
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY, USA
| | | | - Savita Bhutoria
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Gary Gerfen
- Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Craig Branch
- Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY, USA
- Department of Radiology, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Marcos Intaglietta
- Department of Bioengineering, University of California, San Diego, CA, USA
| | - Seetharama A. Acharya
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY, USA
- Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY, USA
| |
Collapse
|
4
|
Abstract
The microvasculature plays a central role in the pathophysiology of hemorrhagic shock and is also involved in arguably all therapeutic attempts to reverse or minimize the adverse consequences of shock. Microvascular studies specific to hemorrhagic shock were reviewed and broadly grouped depending on whether data were obtained on animal or human subjects. Dedicated sections were assigned to microcirculatory changes in specific organs, and major categories of pathophysiological alterations and mechanisms such as oxygen distribution, ischemia, inflammation, glycocalyx changes, vasomotion, endothelial dysfunction, and coagulopathy as well as biomarkers and some therapeutic strategies. Innovative experimental methods were also reviewed for quantitative microcirculatory assessment as it pertains to changes during hemorrhagic shock. The text and figures include representative quantitative microvascular data obtained in various organs and tissues such as skin, muscle, lung, liver, brain, heart, kidney, pancreas, intestines, and mesentery from various species including mice, rats, hamsters, sheep, swine, bats, and humans. Based on reviewed findings, a new integrative conceptual model is presented that includes about 100 systemic and local factors linked to microvessels in hemorrhagic shock. The combination of systemic measures with the understanding of these processes at the microvascular level is fundamental to further develop targeted and personalized interventions that will reduce tissue injury, organ dysfunction, and ultimately mortality due to hemorrhagic shock. Published 2018. Compr Physiol 8:61-101, 2018.
Collapse
Affiliation(s)
- Ivo Torres Filho
- US Army Institute of Surgical Research, JBSA Fort Sam Houston, Texas, USA
| |
Collapse
|
5
|
Experimental Study on the Efficacy of Site-Specific PEGylated Human Serum Albumins in Resuscitation From Hemorrhagic Shock. Crit Care Med 2017; 44:e1090-e1096. [PMID: 27760056 DOI: 10.1097/ccm.0000000000001825] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To evaluate the resuscitative efficacy and the effect on reperfusion injury of two site-specific PEGylated human serum albumins modified with linear or branched PEG20kDa, compared with saline, 8% human serum albumin and 25% human serum albumin, in a hemorrhagic shock model. SETTING Laboratory. SUBJECTS Male Wistar rats. DESIGN Prospective study. INTERVENTIONS Rats were bled to hemorrhagic hypovolemic shock and resuscitated with different resuscitation fluids. MEASUREMENTS AND MAIN RESULTS The mean arterial pressure and blood gas variables were measured. Hemorheology analysis was performed to evaluate the influence of resuscitation on RBCs and blood viscosity. The microvascular state was indirectly characterized in terms of monocyte chemotactic protein-1 and endothelial nitric oxide synthase that related to shear stress and vasodilation, respectively. The levels of inflammation-related factors and apoptosis-related proteins were used to evaluate the reperfusion injury in lungs. The results showed that PEGylated human serum albumin could improve the level of mean arterial pressure and blood gas variables more effectively at the end of resuscitation. poly(ethylene glycol) modification was able to increase the viscosity of human serum albumin to the level of effectively enhancing the expression of monocyte chemotactic protein-1 and endothelial nitric oxide synthase, which could promote microvascular perfusion. The hyperosmotic resuscitative agents including both 25% human serum albumin and PEGylated human serum albumins could greatly attenuate lung injury. No significant therapeutic advantages but some disadvantages were found for Y shaped poly(ethylene glycol) modification over linear poly(ethylene glycol) modification, such as causing the decrease of erythrocyte deformability. CONCLUSIONS Linear high molecular weight site-specific PEGylated human serum albumin is recommended to be used as a hyperosmotic resuscitative agent.
Collapse
|
6
|
Supra-plasma expanders: the future of treating blood loss and anemia without red cell transfusions? JOURNAL OF INFUSION NURSING 2016; 38:217-22. [PMID: 25871869 DOI: 10.1097/nan.0000000000000103] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Oxygen delivery capacity during profoundly anemic conditions depends on blood's oxygen-carrying capacity and cardiac output. Oxygen-carrying blood substitutes and blood transfusion augment oxygen-carrying capacity, but both have given rise to safety concerns, and their efficacy remains unresolved. Anemia decreases oxygen-carrying capacity and blood viscosity. Present studies show that correcting the decrease of blood viscosity by increasing plasma viscosity with newly developed plasma expanders significantly improves tissue perfusion. These new plasma expanders promote tissue perfusion, increasing oxygen delivery capacity without increasing blood oxygen-carrying capacity, thus treating the effects of anemia while avoiding the transfusion of blood.
Collapse
|
7
|
Jilma-Stohlawetz P, Kursten FW, Horvath M, Leitner G, List J, Marcek J, Quehenberger P, Schwameis M, Bartko J, Jilma B. A model comparing how rapidly transfusion of solvent detergent plasma restores clotting factors versus infusion of albumin-saline. Transfus Apher Sci 2015; 53:360-7. [DOI: 10.1016/j.transci.2014.02.028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Revised: 01/17/2014] [Accepted: 02/24/2014] [Indexed: 10/23/2022]
|
8
|
Abstract
The development of oxygen (O2)-carrying blood substitutes has evolved from the goal of replicating blood O2 transport properties to that of preserving microvascular and organ function, reducing the inherent or potential toxicity of the material used to carry O2, and treating pathologies initiated by anemia and hypoxia. Furthermore, the emphasis has shifted from blood replacement fluid to "O2 therapeutics" that restore tissue oxygenation to specific tissues regions. This review covers the different alternatives, potential and limitations of hemoglobin-based O2 carriers (HBOCs) and perfluorocarbon-based O2 carriers (PFCOCs), with emphasis on the physiologic conditions disturbed in the situation that they will be used. It describes how concepts learned from plasma expanders without O2-carrying capacity can be applied to maintain O2 delivery and summarizes the microvascular responses due to HBOCs and PFCOCs. This review also presents alternative applications of HBOCs and PFCOCs namely: 1) How HBOC O2 affinity can be engineered to target O2 delivery to hypoxic tissues; and 2) How the high gas solubility of PFCOCs provides new opportunities for carrying, dissolving, and delivering gases with biological activity. It is concluded that the development of current blood substitutes has amplified their applications horizon by devising therapeutic functions for O2 carriers requiring limited O2 delivery capacity restoration. Conversely, full, blood-like O2-carrying capacity reestablishment awaits the control of O2 carrier toxicity.
Collapse
Affiliation(s)
- Pedro Cabrales
- Department of Bioengineering, University of California, San Diego, La Jolla, California 92093-0412, USA.
| | | |
Collapse
|
9
|
Bonanno FG. Hemorrhagic shock: The "physiology approach". J Emerg Trauma Shock 2012; 5:285-95. [PMID: 23248495 PMCID: PMC3519039 DOI: 10.4103/0974-2700.102357] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2011] [Accepted: 04/13/2011] [Indexed: 11/22/2022] Open
Abstract
A shift of approach from ‘clinics trying to fit physiology’ to the one of ‘physiology to clinics’, with interpretation of the clinical phenomena from their physiological bases to the tip of the clinical iceberg, and a management exclusively based on modulation of physiology, is finally surging as the safest and most efficacious philosophy in hemorrhagic shock. ATLS® classification and recommendations on hemorrhagic shock are not helpful because antiphysiological and potentially misleading. Hemorrhagic shock needs to be reclassified in the direction of usefulness and timing of intervention: in particular its assessment and management need to be tailored to physiology.
Collapse
|
10
|
Chatpun S, Nacharaju P, Cabrales P. Improving cardiac function with new-generation plasma volume expanders. Am J Emerg Med 2012; 31:54-63. [PMID: 22867830 DOI: 10.1016/j.ajem.2012.05.031] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2012] [Revised: 05/24/2012] [Accepted: 05/25/2012] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Plasma expander (PE) based on polyethylene glycol (PEG) conjugated to albumin has shown positive results maintaining blood volume during hemodilution and restoring blood volume during resuscitation from hemorrhagic shock. Polyethylene glycol conjugation to human serum albumin (HSA), PEG-HSA, increases size, weight, and colloidal osmotic pressure, with minor effects on solution viscosity. METHODS This study was designed to test the hypothesis that PEG-HSA (2 g/dL) produced by direct PEGylation chemistry improves cardiac function during 2 experimental models, (i) moderate hemodilution and (ii) resuscitation from hemorrhagic shock, compared with a conventional colloidal PE (Dextran 70 kd [Dx70], 6 g/dL). Cardiac function was studied using a miniaturized pressure volume conductance catheter implanted in the left ventricle and evaluated in terms of cardiac indices derived from the pressure volume measurements. RESULTS Polyethylene glycol-HSA increased cardiac output, stroke volume, and stroke work and decreased systemic vascular resistance compared with Dx70 in both experimental models. The improvements induced by PEG-HSA in cardiac function were sustained over the observation time. Polyethylene glycol-HSA cardiac mechanoenergetics changes are the result of increased energy transferred per stroke and decreased resistance of the vasculature connecting the heart. In summary, PEG-HSA decreased left ventricle ejection impedance. CONCLUSION Ejection of blood diluted with PEG-HSA presented a reduced load to the heart, increased contractile function, and lowered the energy consumed per unit volume compared with Dx70. Our results emphasize the importance of heart function as a parameter to be included in the evaluation changes induced by new PEs.
Collapse
Affiliation(s)
- Surapong Chatpun
- Department of Bioengineering, University of California-San Diego, La Jolla, CA 92093, USA
| | | | | |
Collapse
|
11
|
PEG-albumin plasma expansion increases expression of MCP-1 evidencing increased circulatory wall shear stress: an experimental study. PLoS One 2012; 7:e39111. [PMID: 22720043 PMCID: PMC3375248 DOI: 10.1371/journal.pone.0039111] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2012] [Accepted: 05/16/2012] [Indexed: 11/19/2022] Open
Abstract
Treatment of blood loss with plasma expanders lowers blood viscosity, increasing cardiac output. However, increased flow velocity by conventional plasma expanders does not compensate for decreased viscosity in maintaining vessel wall shear stress (WSS), decreasing endothelial nitric oxide (NO) production. A new type of plasma expander using polyethylene glycol conjugate albumin (PEG-Alb) causes supra-perfusion when used in extreme hemodilution and is effective in treating hemorrhagic shock, although it is minimally viscogenic. An acute 40% hemodilution/exchange-transfusion protocol was used to compare 4% PEG-Alb to Ringer's lactate, Dextran 70 kDa and 6% Hetastarch (670 kDa) in unanesthetized CD-1 mice. Serum cytokine analysis showed that PEG-Alb elevates monocyte chemotactic protein-1 (MCP-1), a member of a small inducible gene family, as well as expression of MIP-1α, and MIP-2. MCP-1 is specific to increased WSS. Given the direct link between increased WSS and production of NO, the beneficial resuscitation effects due to PEG-Alb plasma expansion appear to be due to increased WSS through increased perfusion and blood flow rather than blood viscosity.
Collapse
|
12
|
Taguchi K, Chuang VTG, Maruyama T, Otagiri M. Pharmaceutical aspects of the recombinant human serum albumin dimer: structural characteristics, biological properties, and medical applications. J Pharm Sci 2012; 101:3033-46. [PMID: 22573538 DOI: 10.1002/jps.23181] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2012] [Revised: 04/12/2012] [Accepted: 04/18/2012] [Indexed: 12/15/2022]
Abstract
Human serum albumin is the most abundant protein in the blood. It is clinically used in the treatment of severe hypoalbuminemia and as a plasma expander. The use of albumins as a carrier for drugs is currently being developed, and some are now in the preclinical and clinical trial stages. The main technologies for utilizing an albumin as a drug carrier are protein fusion, polymerization and surface modification, and so on. Among these technologies, albumin dimerization has wide clinical applications as a plasma expander as well as a drug carrier. Despite the fact that many reports have appeared on drugs using an albumin dimer as a carrier, our knowledge of the characteristics of the albumin dimer itself is incomplete. In this review, we summarize the structural characteristics of recombinant albumin dimers produced by two methods, namely, chemical linkage with 1,6-bis(maleimido)hexane and genetically linked with an amino acid linker, and the physicochemical characteristics and biological properties of these preparations. Finally, the potential for pharmaceutical applications of albumin dimers in clinical situations is discussed.
Collapse
Affiliation(s)
- Kazuaki Taguchi
- Department of Biopharmaceutics, Graduate School of Pharmaceutical Sciences, Kumamoto University, Kumamoto 862-0973, Japan
| | | | | | | |
Collapse
|
13
|
Hightower CM, Salazar Vázquez BY, Cabrales P, Tsai AG, Acharya SA, Intaglietta M. Plasma expander and blood storage effects on capillary perfusion in transfusion after hemorrhage. Transfusion 2012; 53:49-59. [PMID: 22554380 DOI: 10.1111/j.1537-2995.2012.03679.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Treating hemorrhage with blood transfusions in subjects previously hemodiluted with different colloidal plasma expanders, using fresh autologous blood or blood that has been stored for 2 weeks, allows identifying the interaction between type of plasma expander and differences in blood storage. STUDY DESIGN AND METHODS Studies used the hamster window chamber model. Fresh autologous plasma, 130-kDa starch-based plasma expander (hydroxyethyl starch [HES]), or 4% polyethylene glycol-conjugated albumin (PEG-Alb) was used for 20% of blood volume (BV) hemodilution. Hemodilution was followed by a 55% by BV 40-minute hemorrhagic shock period, treated with transfusion of fresh or blood that was stored for 2 weeks. Outcome was evaluated 1 hour after blood transfusion in terms of microvascular and systemic variables. RESULTS Results were principally dependent on the type of colloidal solution used during hemodilution, 4% PEG-Alb yielding the best microvascular recovery evaluated in terms of the functional capillary density. This result was consistent whether fresh blood or stored blood was used in treating the subsequent shock period. Fresh blood results were significantly better in systemic and microvascular terms relative to stored blood. HES and fresh plasma hemodilution yielded less favorable results, a difference that was enhanced when fresh versus stored blood was compared in their efficacy of correcting the subsequent hemorrhage. CONCLUSION The type of plasma expander used for hemodilution influences the short-term outcome of subsequent volume resuscitation using blood transfusion, 4% PEG-Alb providing the most favorable outcome by comparison to HES or fresh plasma.
Collapse
Affiliation(s)
- C Makena Hightower
- Department of Bioengineering, University of California at San Diego, La Jolla, CA 92093-0412, USA
| | | | | | | | | | | |
Collapse
|
14
|
Vasoactive hemoglobin solution improves survival in hemodilution followed by hemorrhagic shock. Crit Care Med 2011; 39:1461-6. [PMID: 21336111 DOI: 10.1097/ccm.0b013e3182120cdb] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To compare survival after exchange transfusion followed by hemorrhage using: 1) the vasoactive, oxygen-carrying, bovine hemoglobin-based blood substitute Oxyglobin (Biopure, 12.9 g hemoglobin/dL); and 2) the hydroxyethyl starch plasma expander Hextend (high molecular weight and low degree of substitution, 6%). DESIGN Comparison between treatments. SETTING Laboratory. SUBJECTS Awake hamster chamber window model. INTERVENTIONS Fifty percent blood volume exchange transfusion followed by a 60% hemorrhage over 1 hr, followed by 1 hr of observation. Measurement of blood gases, mean arterial blood pressure, functional capillary density, arteriolar and venular diameter, and Po2 tension distribution. MEASUREMENTS AND MAIN RESULTS Survival with Oxyglobin was 100% and only 50% for the Hextend group. Vasoconstriction was evident in the microcirculation. Mean arterial pressure was higher in the Oxyglobin group. Functional capillary density was significantly reduced, although to a lesser extent by Oxyglobin. There was no difference in microvascular Po2 distribution after 1 hr of shock between groups. CONCLUSIONS Higher mean arterial pressure during the initial stages of hemorrhage could be due to vasoconstriction in the Oxyglobin group as compared to the Hextend group. It is concluded that the pressor effect due to a vasoactive oxygen carrier may be beneficial in maintaining perfusion in conditions of severe hemodilution followed by hypovolemia.
Collapse
|
15
|
Ananda K, Manjula BN, Meng F, Acharya VN, Intaglietta M, Acharya SA. Packing density of the PEG-shell in PEG-albumins: PEGylation induced viscosity and COP are inverse correlate of packing density. ACTA ACUST UNITED AC 2011; 40:14-27. [PMID: 21623695 DOI: 10.3109/10731199.2011.579568] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PEG-Alb represents a new class of low viscogenic plasma expanders that achieve super perfusion in vivo by mimicking the vasodilatory influence of high viscogenic plasma expanders. PEGylation-engineered structure of PEG albumin can be envisaged as a deformable molecular domain around the rigid central protein core. The correlation between the structure of PEG-shell in terms of packing of the PEG inside the PEG shell and PEGylation induced plasma expander (PE)-like properties of albumin has been investigated as a function of the number and length of the PEG-chain. The increase in molecular radius of albumin on PEGylation is non-linear as a function of the number of PEG chains conjugated. The packing density of PEG within the PEG-shell is an inverse correlate of PEG-chain size; i.e. the shorter chains pack more compactly than the longer ones. The PEGylation induced increase in the viscosity and COP of albumin is an exponential correlation of the number of ethylene oxide units (-CH(2)-CH(2)-O-) conjugated and is also a function of the PEG-chain length. At equivalence of PEG mass conjugated, the viscosity and COP of PEG-albumin adducts correlate inversely with packing density of PEG. All PEGylated albumins are not equivalent on the basis of total PEG mass conjugated. Accordingly, the structure of PEG albumin and its solution properties can be engineered to optimize a given total PEG mass for the application of PEG albumin as a resuscitation fluid. The extension arms minimize the influence of PEG shell on the structure of the protein core. We speculate that EAF-PEGylation is a preferable platform for PEGylation of protein therapeutics and is expected to generate products with better therapeutic efficacy.
Collapse
Affiliation(s)
- K Ananda
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | | | | | | | | | | |
Collapse
|
16
|
Effects of a combination hemoglobin based oxygen carrier-hypertonic saline solution on oxygen transport in the treatment of traumatic shock. Resuscitation 2011; 82:937-43. [PMID: 21497981 DOI: 10.1016/j.resuscitation.2011.03.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2010] [Revised: 02/28/2011] [Accepted: 03/07/2011] [Indexed: 11/22/2022]
Abstract
BACKGROUND Logistics complicate fluid resuscitation of traumatic shock on the battlefield. Traumatic shock can result in oxygen debt (O(2)D) accumulation that is fatal. However, the ability of fluid strategies to repay O(2)D are not commonly reported. This pilot study examined various resuscitation fluids, including a combination of PEGylated bovine hemoglobin and hypertonic saline (AfterShock™) on their ability to repay O(2)D in traumatic shock. METHODS 41 anesthetized swine underwent hemorrhage to an O(2)D of 80 mL/kg. Animals received one of the following: 500 mL whole blood, 500 mL AfterShock™, 500 mL hypertonic (7.2%) saline, 250 mL hypertonic (7.2%) saline, 500 mL Hetastarch (6%), or 500 mL lactated Ringer's. Oxygen transport variables (O(2)D, oxygen consumption, oxygen delivery, central venous hemoglobin oxygen saturation, oxygen extraction ratios), lactate clearance, and survival were monitored for 3h after treatment. Data were analyzed using mixed-model ANOVA and comparisons were made to the performance of whole blood. RESULTS Only animals receiving AfterShock™, 500 mL hypertonic saline, and 500 mL Hetastarch survived to 180 min. While not statistically significant AfterShock™ demonstrated trends in improving the repayment of O(2)D and in improving oxygen transport variables despite having lower levels of global oxygen delivery compared to whole blood, Hetastarch and 500 mL hypertonic saline groups. CONCLUSION Use of 500 mL AfterShock™, 500 mL of 7.2% saline or 500 mL of Hetastarch resulted in improved short-term survival. While not statistically significant, AfterShock™ demonstrated trends in improving O(2)D. These findings may have implications for designing resuscitation fluids for combat casualty care.
Collapse
|
17
|
Taguchi K, Urata Y, Anraku M, Watanabe H, Kawai K, Komatsu T, Tsuchida E, Maruyama T, Otagiri M. Superior plasma retention of a cross-linked human serum albumin dimer in nephrotic rats as a new type of plasma expander. Drug Metab Dispos 2010; 38:2124-9. [PMID: 20855459 DOI: 10.1124/dmd.109.031989] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/13/2025] Open
Abstract
Human serum albumin (HSA) is used clinically as a plasma expander in patients with hypoalbuminemia and can also function as a drug carrier. However, the administered HSA is readily eliminated from the blood circulation under pathological conditions, especially the nephrotic syndrome. In this study, we present data on the pharmacokinetics of a structurally defined HSA dimer [two HSA molecules that are cross-linked by reaction with 1,6-bis(maleimido)hexane via Cys34] in nephrotic rats and its superior circulation persistence, owing to the molecular size effect. The half-time (t(1/2)) of the HSA dimer persisted in the circulation 1.3 times longer than that of monomeric HSA in normal rats, primarily because of the suppression of the accumulation of the HSA dimer in the skin and muscle. In nephrotic rats, the t(1/2) of the HSA monomer decreased considerably, whereas the HSA dimer remained unaltered in the blood stream, similar to that for normal rats. As a result, the t(1/2) of the HSA dimer was 2-fold longer than that of the HSA monomer. This longer t(1/2) can be attributed to the fact that accumulation in the kidney and urinary excretion of the HSA dimer were significantly suppressed. The cross-linked HSA dimer shows a longer blood circulation than native HSA monomer in nephrotic rats, which can be attributed to the suppression of renal filtration and leakage into the extravascular space. This HSA dimer has the potential for use as a drug carrier, new plasma expander, and an artificial albumin-based oxygen carrier under a high glomerular permeability condition such as nephrosis.
Collapse
Affiliation(s)
- Kazuaki Taguchi
- Department of Biopharmaceutics, Graduate School of Pharmaceutical Sciences, Kumamoto University, 5-1 Oe-honmachi, Kumamoto 862-0973, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Hu T, Li D, Meng F, Prabhakaran M, Acharya SA. Increased Inter Dimeric Interaction of Oxy Hemoglobin is Necessary for Attenuation of Redutive Pegylation Promoted Dissociation of Tetramer. ACTA ACUST UNITED AC 2010; 39:69-78. [DOI: 10.3109/10731199.2010.501756] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
19
|
Chen K, Pittman RN, Popel AS. Hemorrhagic shock and nitric oxide release from erythrocytic nitric oxide synthase: a quantitative analysis. Microvasc Res 2009; 78:107-18. [PMID: 19285090 PMCID: PMC2782400 DOI: 10.1016/j.mvr.2009.02.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2008] [Revised: 02/21/2009] [Accepted: 02/23/2009] [Indexed: 01/15/2023]
Abstract
A large loss of blood during hemorrhage can result in profound shock, a state of hypotension associated with hemodynamic abnormalities. One of the hypotheses to account for this collapse of homeostasis is that the production of nitric oxide (NO), a gas molecule that dilates blood vessels, is significantly impaired during hemorrhage, resulting in a mismatch between O(2) delivery and the metabolic activity in the tissues. NO can be released from multiple sources in the vasculature. Recent studies have shown that erythrocytes express functional endothelial nitric oxide synthase (NOS3), which potentially serves as an intraluminal NO source. NO delivery from this source is complex: erythrocytes are not only NO producers but also act as potent sinks because of the high affinity of NO for hemoglobin. To test our hypothesis that the loss of erythrocytic NOS3 during hemorrhage contributes to NO deficiency-related shock, we have constructed a multicellular computational model that simulates NO production and transport to allow us to quantify the loss of NO under different hemorrhagic conditions. Our model shows that: (1) during mild hemorrhage and subsequent hemodilution (hematocrit >30%), NO from this intraluminal source is only slightly decreased in the vascular smooth muscle, but the NO level is significantly reduced under severe hemorrhagic conditions (hematocrit <30%); (2) whether a significant amount of NO from this source can be delivered to vascular smooth muscle is strongly dependent on the existence of a protective mechanism for NO delivery; (3) if the expression level of NOS3 on erythrocytes is similar to that on endothelial cells, we estimate approximately 13 pM NO at the vascular smooth muscle from this source when such a protective mechanism is involved. This study provides a basis for detailed studies to characterize the impairment of NO release pathways during hemorrhage and yield important insights for the development of resuscitation methods.
Collapse
Affiliation(s)
- Kejing Chen
- Department of Biomedical Engineering, School of Medicine, Johns Hopkins University, 613 Traylor Building, 720 Rutland Avenue, Baltimore, MD 21205, USA.
| | | | | |
Collapse
|
20
|
Microcirculatory effects of intravenous fluids in critical illness: plasma expansion beyond crystalloids and colloids. Curr Opin Anaesthesiol 2009; 22:163-7. [DOI: 10.1097/aco.0b013e328328d304] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
21
|
Creagh-Brown BC, Evans TW. The promise of next generation colloids. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2008; 12:147. [PMID: 18492220 PMCID: PMC2481445 DOI: 10.1186/cc6892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
The aim of perioperative haemodilution is to reduce loss of red blood cells during elective surgery. The oncotic and molecular characteristics of the various plasma substitutes employed determine how effectively normovolaemia is maintained, and their non-oncotic effects include alterations in microvascular perfusion. In the previous issue of Critical Care, Martini and colleagues assessed the effects of haemodilution with either polyethylene glycol (PEG)ylated albumin or a commercially available hydroxyethyl starch-based colloid in a hamster haemorrhage model. PEGylated albumin was superior to hydroxyethyl starch, as reflected by survival, haemodynamic parameters and assessment of the microcirculation using intravital microscopy.
Collapse
Affiliation(s)
- Ben C Creagh-Brown
- Department of Critical Care, Imperial College School of Medicine, Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK
| | | |
Collapse
|