1
|
Pan D, Hu J, Wang B, Xia X, Cheng Y, Wang C, Lu Y. Biomimetic Wearable Sensors: Emerging Combination of Intelligence and Electronics. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2303264. [PMID: 38044298 PMCID: PMC10837381 DOI: 10.1002/advs.202303264] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 10/03/2023] [Indexed: 12/05/2023]
Abstract
Owing to the advancement of interdisciplinary concepts, for example, wearable electronics, bioelectronics, and intelligent sensing, during the microelectronics industrial revolution, nowadays, extensively mature wearable sensing devices have become new favorites in the noninvasive human healthcare industry. The combination of wearable sensing devices with bionics is driving frontier developments in various fields, such as personalized medical monitoring and flexible electronics, due to the superior biocompatibilities and diverse sensing mechanisms. It is noticed that the integration of desired functions into wearable device materials can be realized by grafting biomimetic intelligence. Therefore, herein, the mechanism by which biomimetic materials satisfy and further enhance system functionality is reviewed. Next, wearable artificial sensory systems that integrate biomimetic sensing into portable sensing devices are introduced, which have received significant attention from the industry owing to their novel sensing approaches and portabilities. To address the limitations encountered by important signal and data units in biomimetic wearable sensing systems, two paths forward are identified and current challenges and opportunities are presented in this field. In summary, this review provides a further comprehensive understanding of the development of biomimetic wearable sensing devices from both breadth and depth perspectives, offering valuable guidance for future research and application expansion of these devices.
Collapse
Affiliation(s)
- Donglei Pan
- College of Light Industry and Food EngineeringGuangxi UniversityNanningGuangxi530004China
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Jiawang Hu
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Bin Wang
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Xuanjie Xia
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Yifan Cheng
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| | - Cheng‐Hua Wang
- College of Light Industry and Food EngineeringGuangxi UniversityNanningGuangxi530004China
| | - Yuan Lu
- Key Laboratory of Industrial BiocatalysisMinistry of EducationDepartment of Chemical EngineeringTsinghua UniversityBeijing100084China
| |
Collapse
|
2
|
Ergun O, Yildirim O, Bozyel I, Kaymak I, Gokcen D, Sennaroglu L. The hidden cochlear implant. J Laryngol Otol 2023; 137:1207-1214. [PMID: 36751901 DOI: 10.1017/s0022215123000130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
OBJECTIVE The hidden cochlear implant concept has two data transmission methods: Bluetooth low energy and transtympanic optical data transfer systems. This study aimed to present the hidden cochlear implant and compare the test results with the existing fully implanted cochlear implant. METHOD The Bluetooth low energy module was implanted into the implant bed. For the transtympanic optical data transfer tests, a receiver was passed through the posterior tympanotomy, and the transmitter was placed in the ear canal. RESULTS The Bluetooth low energy module range was 5.2-17.5 m. Transtympanic optical data transfer reached a rate of 1 Mbit/s and had 99.22 per cent accuracy. Despite various obstacles, the accuracy of the transtympanic optical data transfer was more than 99 per cent with a 250 Kbit/s rate. The average power consumption was 310 mW for the implanted Bluetooth low energy module and 41 mW for the transtympanic optical data transfer receiver. CONCLUSION Bluetooth low energy is suitable to be used transcutaneously. Transtympanic optical data transfer is an effective and promising technology. Hidden use cochlear implants aim to have the aesthetics of a fully implantable cochlear implant with higher reliability and a magnet-free design with smart device integration.
Collapse
Affiliation(s)
- O Ergun
- Department of Otorhinolaryngology Head and Neck Surgery, Baskent University Hospital, Ankara, Turkey
| | - O Yildirim
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Hacettepe University, Ankara, Turkey
| | - I Bozyel
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Hacettepe University, Ankara, Turkey
| | - I Kaymak
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Hacettepe University, Ankara, Turkey
| | - D Gokcen
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Hacettepe University, Ankara, Turkey
| | - L Sennaroglu
- Department of Otorhinolaryngology Head and Neck Surgery, Faculty of Medicine, Hacettepe University, Ankara, Turkey
| |
Collapse
|
3
|
Hrncirik F, Roberts I, Sevgili I, Swords C, Bance M. Models of Cochlea Used in Cochlear Implant Research: A Review. Ann Biomed Eng 2023; 51:1390-1407. [PMID: 37087541 PMCID: PMC10264527 DOI: 10.1007/s10439-023-03192-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 03/20/2023] [Indexed: 04/24/2023]
Abstract
As the first clinically translated machine-neural interface, cochlear implants (CI) have demonstrated much success in providing hearing to those with severe to profound hearing loss. Despite their clinical effectiveness, key drawbacks such as hearing damage, partly from insertion forces that arise during implantation, and current spread, which limits focussing ability, prevent wider CI eligibility. In this review, we provide an overview of the anatomical and physical properties of the cochlea as a resource to aid the development of accurate models to improve future CI treatments. We highlight the advancements in the development of various physical, animal, tissue engineering, and computational models of the cochlea and the need for such models, challenges in their use, and a perspective on their future directions.
Collapse
Affiliation(s)
- Filip Hrncirik
- Cambridge Hearing Group, Cambridge, UK.
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK.
| | - Iwan Roberts
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Ilkem Sevgili
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Chloe Swords
- Cambridge Hearing Group, Cambridge, UK
- Department of Physiology, Development and Neurosciences, University of Cambridge, Cambridge, CB2 3DY, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| |
Collapse
|
4
|
Future regenerative medicine developments and their therapeutic applications. Biomed Pharmacother 2023; 158:114131. [PMID: 36538861 DOI: 10.1016/j.biopha.2022.114131] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 12/05/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
Although the currently available pharmacological assays can cure most pathological disorders, they have limited therapeutic value in relieving certain disorders like myocardial infarct, peripheral vascular disease, amputated limbs, or organ failure (e.g. renal failure). Pilot studies to overcome such problems using regenerative medicine (RM) delivered promising data. Comprehensive investigations of RM in zebrafish or reptilians are necessary for better understanding. However, the precise mechanisms remain poorly understood despite the tremendous amount of data obtained using the zebrafish model investigating the exact mechanisms behind their regenerative capability. Indeed, understanding such mechanisms and their application to humans can save millions of lives from dying due to potentially life-threatening events. Recent studies have launched a revolution in replacing damaged human organs via different approaches in the last few decades. The newly established branch of medicine (known as Regenerative Medicine aims to enhance natural repair mechanisms. This can be done through the application of several advanced broad-spectrum technologies such as organ transplantation, tissue engineering, and application of Scaffolds technology (support vascularization using an extracellular matrix), stem cell therapy, miRNA treatment, development of 3D mini-organs (organoids), and the construction of artificial tissues using nanomedicine and 3D bio-printers. Moreover, in the next few decades, revolutionary approaches in regenerative medicine will be applied based on artificial intelligence and wireless data exchange, soft intelligence biomaterials, nanorobotics, and even living robotics capable of self-repair. The present work presents a comprehensive overview that summarizes the new and future advances in the field of RM.
Collapse
|
5
|
Yamazaki H, Kohno Y, Kawano S. Oscillation Characteristics of an Artificial Cochlear Sensory Epithelium Optimized for a Micrometer-Scale Curved Structure. MICROMACHINES 2022; 13:mi13050768. [PMID: 35630235 PMCID: PMC9147464 DOI: 10.3390/mi13050768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 05/09/2022] [Accepted: 05/10/2022] [Indexed: 02/01/2023]
Abstract
Based on the modern microelectromechanical systems technology, we present a revolutionary miniaturized artificial cochlear sensory epithelium for future implantation tests on guinea pigs. The device was curved to fit the spiral structure of the cochlea and miniaturized to a maximum dimension of <1 mm to be implanted in the cochlea. First, the effect of the curved configuration on the oscillation characteristics of a trapezoidal membrane was evaluated using the relatively larger devices, which had a trapezoidal and a comparable curved shape designed for high-precision in vitro measurements. Both experimental and numerical analyses were used to determine the resonance frequencies and positions, and multiple oscillation modes were clearly observed. Because the maximum oscillation amplitude positions, i.e., the resonance positions, differed depending on the resonance frequencies in both trapezoidal and curved membrane devices, the sound frequency was determined based on the resonance position, thus reproducing the frequency selectivity of the basilar membrane in the organ of Corti. Furthermore, the resonance frequencies and positions of these two devices with different configurations were determined to be quantitatively consistent and similar in terms of mechanical dynamics. This result shows that despite a curved angle of 50−60°, the effect of the curved shape on oscillation characteristics was negligible. Second, the nanometer-scale oscillation of the miniaturized device was successfully measured, and the local resonance frequency in air was varied from 157 to 277 kHz using an experimental system that could measure the amplitude distribution in a two-dimensional (2D) plane with a high accuracy and reproducibility at a high speed. The miniaturized device developed in this study was shown to have frequency selectivity, and when the device was implanted in the cochlea, it was expected to discriminate frequencies in the same manner as the basilar membrane in the biological system. This study established methods for fabricating and evaluating the miniaturized device, and the proposed miniaturized device in a curved shape demonstrated the feasibility of next-generation cochlear implants.
Collapse
|
6
|
Yamazaki H, Tsuji T, Doi K, Kawano S. Mathematical model of the auditory nerve response to stimulation by a micro-machined cochlea. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3430. [PMID: 33336933 DOI: 10.1002/cnm.3430] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 11/20/2020] [Accepted: 12/13/2020] [Indexed: 06/12/2023]
Abstract
We report a novel mathematical model of an artificial auditory system consisting of a micro-machined cochlea and the auditory nerve response it evokes. The modeled micro-machined cochlea is one previously realized experimentally by mimicking functions of the cochlea [Shintaku et al, Sens. Actuat. 158 (2010) 183-192; Inaoka et al, Proc. Natl. Acad. Sci. USA 108 (2011) 18390-18395]. First, from the viewpoint of mechanical engineering, the frequency characteristics of a model device were experimentally investigated to develop an artificial basilar membrane based on a spring-mass-damper system. In addition, a nonlinear feedback controller mimicking the function of the outer hair cells was incorporated in this experimental system. That is, the developed device reproduces the proportional relationship between the oscillation amplitude of the basilar membrane and the cube root of the sound pressure observed in the mammalian auditory system, which is what enables it to have a wide dynamic range, and the characteristics of the control performance were evaluated numerically and experimentally. Furthermore, the stimulation of the auditory nerve by the micro-machined cochlea was investigated using the present mathematical model, and the simulation results were compared with our previous experimental results from animal testing [Shintaku et al, J. Biomech. Sci. Eng. 8 (2013) 198-208]. The simulation results were found to be in reasonably good agreement with those from the previous animal test; namely, there exists a threshold at which the excitation of the nerve starts and a saturation value for the firing rate under a large input. The proposed numerical model was able to qualitatively reproduce the results of the animal test with the micro-machined cochlea and is thus expected to guide the evaluation of micro-machined cochleae for future animal experiments.
Collapse
Affiliation(s)
- Hiroki Yamazaki
- Graduate School of Engineering Science, Osaka University, Osaka, Japan
| | - Tetsuro Tsuji
- Graduate School of Engineering Science, Osaka University, Osaka, Japan
| | - Kentaro Doi
- Graduate School of Engineering Science, Osaka University, Osaka, Japan
| | - Satoyuki Kawano
- Graduate School of Engineering Science, Osaka University, Osaka, Japan
| |
Collapse
|
7
|
Ahmadi H, Moradi H, Pastras CJ, Abolpour Moshizi S, Wu S, Asadnia M. Development of Ultrasensitive Biomimetic Auditory Hair Cells Based on Piezoresistive Hydrogel Nanocomposites. ACS APPLIED MATERIALS & INTERFACES 2021; 13:44904-44915. [PMID: 34516096 DOI: 10.1021/acsami.1c12515] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
With an ageing population, hearing disorders are predicted to rise considerably in the following decades. Thus, developing a new class of artificial auditory system has been highlighted as one of the most exciting research topics for biomedical applications. Herein, a design of a biocompatible piezoresistive-based artificial hair cell sensor is presented consisting of a highly flexible and conductive polyvinyl alcohol (PVA) nanocomposite with vertical graphene nanosheets (VGNs). The bilayer hydrogel sensor demonstrates excellent performance to mimic biological hair cells, responding to acoustic stimuli in the audible range between 60 Hz to 20 kHz. The sensor output demonstrates stable mid-frequency regions (∼4-9 kHz), with the greatest sensitivity as high frequencies (∼13-20 kHz). This is somewhat akin to the mammalian auditory system, which has remarkable sensitivity and sharp tuning at high frequencies due to the "active process". This work validates the PVA/VGN sensor as a potential candidate to play a similar functional role to that of the cochlear hair cells, which also operate over a wide frequency domain in a viscous environment. Further characterizations of the sensor show that increasing the sound amplitude results in higher responses from the sensor while taking it to the depth drops the sensor outputs due to attenuation of sound in water. Meanwhile, the acoustic pressure distribution of sound waves is predicted through finite element analysis, whereby the numerical results are in perfect agreement with experimental data. This proof-of-concept work creates a platform for the future design of susceptible, flexible biomimetic sensors to closely mimic the biological cochlea.
Collapse
Affiliation(s)
- Hadi Ahmadi
- School of Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | - Hamed Moradi
- School of Mechanical Engineering, Sharif University of Technology, Tehran 14588-89694, Iran
| | - Christopher J Pastras
- School of Medical Sciences, The University of Sydney, Sydney, New South Wales 2050, Australia
| | | | - Shuying Wu
- School of Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | - Mohsen Asadnia
- School of Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| |
Collapse
|
8
|
Zhang Y, Gao X, Wu Y, Gui J, Guo S, Zheng H, Wang ZL. Self-powered technology based on nanogenerators for biomedical applications. EXPLORATION (BEIJING, CHINA) 2021; 1:90-114. [PMID: 37366464 PMCID: PMC10291576 DOI: 10.1002/exp.20210152] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 07/09/2021] [Indexed: 06/28/2023]
Abstract
Biomedical electronic devices have enormous benefits for healthcare and quality of life. Still, the long-term working of those devices remains a great challenge due to the short life and large volume of conventional batteries. Since the nanogenerators (NGs) invention, they have been widely used to convert various ambient mechanical energy sources into electrical energy. The self-powered technology based on NGs is dedicated to harvesting ambient energy to supply electronic devices, which is an effective pathway to conquer the energy insufficiency of biomedical electronic devices. With the aid of this technology, it is expected to develop self-powered biomedical electronic devices with advanced features and distinctive functions. The goal of this review is to summarize the existing self-powered technologies based on NGs and then review the applications based on self-powered technologies in the biomedical field during their rapid development in recent years, including two main directions. The first is the NGs as independent sensors to converts biomechanical energy and heat energy into electrical signals to reflect health information. The second direction is to use the electrical energy produced by NGs to stimulate biological tissues or powering biomedical devices for achieving the purpose of medical application. Eventually, we have analyzed and discussed the remaining challenges and perspectives of the field. We believe that the self-powered technology based on NGs would advance the development of modern biomedical electronic devices.
Collapse
Affiliation(s)
- Yuanzheng Zhang
- Key Laboratory of Artificial Micro‐ and Nano‐structures of Ministry of EducationSchool of Physics and TechnologyWuhan UniversityWuhanP. R. China
- International Joint Research Laboratory of New Energy Materials and Devices of Henan ProvinceHenan UniversityKaifengP. R. China
| | - Xiangyang Gao
- Key Laboratory of Artificial Micro‐ and Nano‐structures of Ministry of EducationSchool of Physics and TechnologyWuhan UniversityWuhanP. R. China
| | - Yonghui Wu
- International Joint Research Laboratory of New Energy Materials and Devices of Henan ProvinceHenan UniversityKaifengP. R. China
| | - Jinzheng Gui
- Key Laboratory of Artificial Micro‐ and Nano‐structures of Ministry of EducationSchool of Physics and TechnologyWuhan UniversityWuhanP. R. China
| | - Shishang Guo
- Key Laboratory of Artificial Micro‐ and Nano‐structures of Ministry of EducationSchool of Physics and TechnologyWuhan UniversityWuhanP. R. China
| | - Haiwu Zheng
- International Joint Research Laboratory of New Energy Materials and Devices of Henan ProvinceHenan UniversityKaifengP. R. China
| | - Zhong Lin Wang
- Beijing Institute of Nanoenergy and NanosystemsChinese Academy of SciencesBeijingP. R. China
- School of Materials Science and EngineeringGeorgia Institute of TechnologyAtlantaGeorgiaUSA
| |
Collapse
|
9
|
Latif R, Noor MM, Yunas J, Hamzah AA. Mechanical Energy Sensing and Harvesting in Micromachined Polymer-Based Piezoelectric Transducers for Fully Implanted Hearing Systems: A Review. Polymers (Basel) 2021; 13:polym13142276. [PMID: 34301034 PMCID: PMC8309449 DOI: 10.3390/polym13142276] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 06/29/2021] [Accepted: 07/01/2021] [Indexed: 01/12/2023] Open
Abstract
The paper presents a comprehensive review of mechanical energy harvesters and microphone sensors for totally implanted hearing systems. The studies on hearing mechanisms, hearing losses and hearing solutions are first introduced to bring to light the necessity of creating and integrating the in vivo energy harvester and implantable microphone into a single chip. The in vivo energy harvester can continuously harness energy from the biomechanical motion of the internal organs. The implantable microphone executes mechanoelectrical transduction, and an array of such structures can filter sound frequency directly without an analogue-to-digital converter. The revision of the available transduction mechanisms, device configuration structures and piezoelectric material characteristics reveals the advantage of adopting the polymer-based piezoelectric transducers. A dual function of sensing the sound signal and simultaneously harvesting vibration energy to power up its system can be attained from a single transducer. Advanced process technology incorporates polymers into piezoelectric materials, initiating the invention of a self-powered and flexible transducer that is compatible with the human body, magnetic resonance imaging system (MRI) and the standard complementary metal-oxide-semiconductor (CMOS) processes. The polymer-based piezoelectric is a promising material that satisfies many of the requirements for obtaining high performance implantable microphones and in vivo piezoelectric energy harvesters.
Collapse
|
10
|
Diversiform sensors and sensing systems driven by triboelectric and piezoelectric nanogenerators. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2020.213597] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
11
|
Yamazaki H, Yamanaka D, Kawano S. A Preliminary Prototype High-Speed Feedback Control of an Artificial Cochlear Sensory Epithelium Mimicking Function of Outer Hair Cells. MICROMACHINES 2020; 11:mi11070644. [PMID: 32610696 PMCID: PMC7407979 DOI: 10.3390/mi11070644] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 06/22/2020] [Accepted: 06/26/2020] [Indexed: 12/20/2022]
Abstract
A novel feedback control technique for the local oscillation amplitude in an artificial cochlear sensory epithelium that mimics the functions of the outer hair cells in the cochlea is successfully developed and can be implemented with a control time on the order of hundreds of milliseconds. The prototype artificial cochlear sensory epithelium was improved from that developed in our previous study to enable the instantaneous determination of the local resonance position based on the electrical output from a bimorph piezoelectric membrane. The device contains local patterned electrodes deposited with micro electro mechanical system (MEMS) technology that is used to detect the electrical output and oscillate the device by applying local electrical stimuli. The main feature of the present feedback control system is the principle that the resonance position is recognized by simultaneously measuring the local electrical outputs of all of the electrodes and comparing their magnitudes, which drastically reduces the feedback control time. In this way, it takes 0.8 s to control the local oscillation of the device, representing the speed of control with the order of one hundred times relative to that in the previous study using the mechanical automatic stage to scan the oscillation amplitude at each electrode. Furthermore, the intrinsic difficulties in the experiment such as the electrical measurement against the electromagnetic noise, adhesion of materials, and fatigue failure mechanism of the oscillation system are also shown and discussed in detail based on the many scientific aspects. The basic knowledge of the MEMS fabrication and the experimental measurement would provide useful suggestions for future research. The proposed preliminary prototype high-speed feedback control can aid in the future development of fully implantable cochlear implants with a wider dynamic range.
Collapse
|